■ FP-X Control Unit Dimensions (Unit: mm)
Dimensions when add-on cassettes
(function and communication) are installed
●AFPX-C14 ∗ ∗ (The same dimensions apply to the expansion I/O unit AFPX-E16∗)
COM
Status display LED
N
X5
X3
X0
X2
X4
X7
X6
PROG. ERR.
0
X 4
0
Y 4
Programmable Controller
45
L
RUN
Input/output display LED
Application cassette
Communication cassette
X1
FP-X
60
3
7
3
5
90
Panasonic
RUN
PROG.
Mode selection switch
RUN/PROG.
FP-X C14
min.
max.
V0
V1
45
Analog volume
Tool port connector
0V
Y0
24V
Y2
Y1
C0
C1
C2
Y5
Y3
C3
Y4
13.6
79
3.5
Application cassette
Communication cassette
Battery
Expansion unit connector
ARCT1B287E
DIN hook
Cassette attachment area 1
8.6
79
*AFPX-COM5 Communication Cassette (Ethernet type): 5 mm higher
●AFPX-C30 ∗ ∗ (The same dimensions apply to the expansion I/O unit AFPX-E30∗∗)
100
Status display LED
N COM
L
COM
RUN
Input/output display LED
Y
X3
X2
X5
X4
X7
X6
X9
X8
XB
XA
XD
XC
Mounting dimension diagram
XF
Strengthened Product Lineup
to Meet Diversified Demands
Mounting dimensions for expansion
L2
L2
XE
PROG. ERR.
0
8
0
8
X
X1
X0
7
F
7
D
Panasonic
90
FP-X C30
Mode selection switch
RUN/PROG.
RUN
PROG.
max.
8
H
min.
V0
Analog volume
V1
0V
USB connector
24V
Tool port connector
Y0
C0
Y1
C1
Y2
C2
C3
Y4
Y3
Y5
Y7
Y6
Y9
Y8
YA
C4
YC
YB
L2
52
C30, E30
92
C60
182
82
(mm)
2-M4 or 2-5 dia.
Application cassette
Battery
Expansion unit connector
●AFPX-C60 ∗ ∗
H
(Tolerance: ±0.5)
YD
Cassette attachment area 1 Cassette attachment area 2
Application cassette
Communication cassette
Battery
Type
C14, E16
190
N COM
L
COM
RUN
X
Y
Mode selection switch
RUN/PROG.
X0
PROG.
X3
X2
X5
X4
XA
XF
XD
COM
NC
XE
XC
COM
COM
X11
X10
COM
X13
X15
X14
X12
X19
X17
X16
X18
X1B
X1A
X1D
X1C
X1F
X1E
ERR.
F
1F
D
1D
FP-X C60
V1
V2
max.
V3
0V
Tool port connector
X8
XB
max.
V0
min.
USB connector
X9
Panasonic
min.
24V
X6
7 8
17 18
7 8
17 18
0
10
0
10
RUN
PROG.
Analog volume
X7
Y0
C0
Y1
C1
Y2
C2
C3
Y4
Y3
Y5
Y7
Y6
Y9
Y8
YA
C4
Y10
YC
YB
YD
Cassette attachment area 1
Application cassette
Communication cassette
Battery
C0
Y11
C1
C2
Y12
Y13
C3
Y14
C4
C5
Y15
Y17
Y16
Y1A
Y19
Y18
C6
Y1C
Y1B
Cassette attachment area 2
Application cassette
Battery
Y1D
Expansion connector part
Battery
Expansion unit connector
■ FP-X Expansion FP0 Adapter Dimensions (Unit: mm)
( 0.5 )
25
60
POWER
I/F
L
ERROR
45
Status
display LED
(7)
Panasonic
Expansion connector
90
AFPX-EFP0
FP0-A80
When the expansion
connector is
attached
45
Input/output display LED
X1
90
Status display LED
Appearance when mounted
with a C14 control unit
3.5
DIN hook
Power connector 24 V DC
Expansion hook
These materials are printed on ECF pulp.
These materials are printed with earth-friendly vegetable-based (soybean oil) ink.
Please contact ..........
Matsushita Electric Works, Ltd.
Automation Controls Business Unit
Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan
Telephone: +81-6-6908-1050
Facsimile: +81-6-6908-5781
http://www.mew.co.jp/ac/e
FP-X Programmable Controller
ARCT1B287E '07.5
All Rights Reserved © 2007 COPYRIGHT Matsushita Electric Works, Ltd.
ARCT1B287E 200705-5YT
Specifications are subject to change without notice.
Printed in Japan.
http://www.mew.co.jp/ac/e
Matsushita Electric Works, Ltd.
High Performance, Multiple Functions, and Strengthened
Lineup to Support a Wider Variety of Applications
High-speed Operation
Control Unit:
Faster operation of basic instructions
Faster operation of high-level instructions
E.g. ST, AN or OR
E.g. floating point operation instructions
18 Types
(14, 30 or 60 points) × (Relay, NPN or PNP) × (AC or DC)
Reduction of total scan time
Expansion Unit:
Large Capacity Program Memory
FP-X, which is equipped with 32k steps*2 program memory, is ideal for fully
covering the increasing functions, such as communications, positioning, and
analog control. The sufficient program capacity can also support future
equipment modifications.
*2 C14: 16k steps
Multi-axial positioning
Temperature control
Increase in
number and
complexity
of programs
Network
SCADA system
Displays
9 Types
(16 points) × (Relay, NPN or PNP)
(30 points) × (Relay, NPN or PNP) × (AC or DC)
Data processing
Multi-point I/O
43 Combinations
Measuring instrument
(Number of I/O Points)
Independent Comment Memory
There are difficulties with program management on a PC, such as identifying
the latest program. The use of the program in the PLC of equipment in
operation is often regarded as the best option. Since FP-X has an
independent comment memory, all comments can be stored in the PLC
together with programs, facilitating program management and maintenance.
14 to 300 points
Inside of FP-X
Add-on Cassette:
Comment
Program
Independent
memory
memory
Relay output
Control unit
*1 Basic instructions: 40%, Data transfer and operation instructions: 60%
Expansion unit
The 32-bit RISC processor provides the top-level processing speed in
compact PLCs. The scan time is 2 ms or less for 5,000 steps*1. A highspeed PLC is indispensable for enhancing the functionality of equipment.
NPN output
PNP output
AC
DC
AC
DC
AC
DC
14 points
●
●
●
●
●
●
30 points
●
●
●
●
●
●
60 points
●
●
●
●
●
●
16 points (Without a power
supply section)
30 points
●
●
●
(Without a power
supply section)
●
●
●
●
(Without a power
supply section)
●
●
16 Types
Digital I/O, Pulse I/O, Analog I/O, Communication
(RS485, RS232C, Ethernet), External memory
Maximum Number of I/O Points
Since up to eight expansion units can be connected to one control unit, the
maximum number of I/O points is 300. Furthermore, with the add-on
cassette and expansion FP0 adapter connected, the number of I/O points
can be increased to 382.
Up to Three Channels
Three channels are available with a combination of a communication cassette (two-channel
type) and the tool port.
The combinations of a wide variety of communication functions can support diversified applications.
AFPX-C30R
Ethernet
(Add-on cassette attached)
With a communication cassette (Ethernet type), inspection data, production
data, and error information can be easily collected.
Modbus-RTU
Built-in 4-axis Pulse Output (Transistor Output Type)
The transistor output type C14 comes with 3-axis while C30/60 comes with 4-axis pulse output
built-in the control unit. The multi-axis control, which previously required a higher-level PLC or
additional positioning unit, or two or more PLC units, can now be achieved with only one FP-X
transistor output type unit in a small space at a low cost. In addition, as this type does not
require a pulse I/O cassette needed for a relay output type, other function expansion cassettes
such as communication or analog input can be attached for more diversified applications.
Modbus-RTU
Communications with equipment compatible with Modbus-RTU (binary), a
worldwide de-facto standard, are available without programming. E.g.
temperature controllers and inverters
Ethernet
PLC Link
With a communication cassette (RS485 type), bit data/word data can be
easily shared among up to 16 FP-X units.
Computer Link
XY Table + Processing Head
Semiconductor Wafer Takeout Blade
3-axis Control with C14.
4-axis Control with C30/C60
Max.
3 Ports
General-purpose Serial
Communications
PLC-Link
Easy communications with equipment compatible with Matsushita's open
protocol "MEWTOCOL" are available without programming. E.g. displays,
image processors, temperature controllers, and power meters
General-purpose Serial Communications
Commands are generated/transmitted in accordance with the communication protocol of the target
equipment.
Or, nonprocedural data receiving is available. E.g. measuring instruments, barcode readers, and RF-ID
2
Computer
Link
100kHz x
2 axes
20kHz x
2 axes
3
High Performance, Multiple Functions, and Strengthened
Lineup to Support a Wider Variety of Applications
High-speed Operation
Control Unit:
Faster operation of basic instructions
Faster operation of high-level instructions
E.g. ST, AN or OR
E.g. floating point operation instructions
18 Types
(14, 30 or 60 points) × (Relay, NPN or PNP) × (AC or DC)
Reduction of total scan time
Expansion Unit:
Large Capacity Program Memory
FP-X, which is equipped with 32k steps*2 program memory, is ideal for fully
covering the increasing functions, such as communications, positioning, and
analog control. The sufficient program capacity can also support future
equipment modifications.
*2 C14: 16k steps
Multi-axial positioning
Temperature control
Increase in
number and
complexity
of programs
Network
SCADA system
Displays
9 Types
(16 points) × (Relay, NPN or PNP)
(30 points) × (Relay, NPN or PNP) × (AC or DC)
Data processing
Multi-point I/O
43 Combinations
Measuring instrument
(Number of I/O Points)
Independent Comment Memory
There are difficulties with program management on a PC, such as identifying
the latest program. The use of the program in the PLC of equipment in
operation is often regarded as the best option. Since FP-X has an
independent comment memory, all comments can be stored in the PLC
together with programs, facilitating program management and maintenance.
14 to 300 points
Inside of FP-X
Add-on Cassette:
Comment
Program
Independent
memory
memory
Relay output
Control unit
*1 Basic instructions: 40%, Data transfer and operation instructions: 60%
Expansion unit
The 32-bit RISC processor provides the top-level processing speed in
compact PLCs. The scan time is 2 ms or less for 5,000 steps*1. A highspeed PLC is indispensable for enhancing the functionality of equipment.
NPN output
PNP output
AC
DC
AC
DC
AC
DC
14 points
●
●
●
●
●
●
30 points
●
●
●
●
●
●
60 points
●
●
●
●
●
●
16 points (Without a power
supply section)
30 points
●
●
●
(Without a power
supply section)
●
●
●
●
(Without a power
supply section)
●
●
16 Types
Digital I/O, Pulse I/O, Analog I/O, Communication
(RS485, RS232C, Ethernet), External memory
Maximum Number of I/O Points
Since up to eight expansion units can be connected to one control unit, the
maximum number of I/O points is 300. Furthermore, with the add-on
cassette and expansion FP0 adapter connected, the number of I/O points
can be increased to 382.
Up to Three Channels
Three channels are available with a combination of a communication cassette (two-channel
type) and the tool port.
The combinations of a wide variety of communication functions can support diversified applications.
AFPX-C30R
Ethernet
(Add-on cassette attached)
With a communication cassette (Ethernet type), inspection data, production
data, and error information can be easily collected.
Modbus-RTU
Built-in 4-axis Pulse Output (Transistor Output Type)
The transistor output type C14 comes with 3-axis while C30/60 comes with 4-axis pulse output
built-in the control unit. The multi-axis control, which previously required a higher-level PLC or
additional positioning unit, or two or more PLC units, can now be achieved with only one FP-X
transistor output type unit in a small space at a low cost. In addition, as this type does not
require a pulse I/O cassette needed for a relay output type, other function expansion cassettes
such as communication or analog input can be attached for more diversified applications.
Modbus-RTU
Communications with equipment compatible with Modbus-RTU (binary), a
worldwide de-facto standard, are available without programming. E.g.
temperature controllers and inverters
Ethernet
PLC Link
With a communication cassette (RS485 type), bit data/word data can be
easily shared among up to 16 FP-X units.
Computer Link
XY Table + Processing Head
Semiconductor Wafer Takeout Blade
3-axis Control with C14.
4-axis Control with C30/C60
Max.
3 Ports
General-purpose Serial
Communications
PLC-Link
Easy communications with equipment compatible with Matsushita's open
protocol "MEWTOCOL" are available without programming. E.g. displays,
image processors, temperature controllers, and power meters
General-purpose Serial Communications
Commands are generated/transmitted in accordance with the communication protocol of the target
equipment.
Or, nonprocedural data receiving is available. E.g. measuring instruments, barcode readers, and RF-ID
2
Computer
Link
100kHz x
2 axes
20kHz x
2 axes
3
The Highly Expandable Lineup
Satisfies Wide Range of Demands.
FP-X Name and Function of Each Part
The flexible product lineup designed for rapidly responding
to user needs provides a high level of satisfaction.
Control Unit
Input terminals
Power terminals
Product Lineup
Control Unit
Relay output
Add-on cassette interface cover
Transistor output
DC power supply
AC power supply
DC power supply
AC power supply
AFPX-C14RD
AFPX-C14R
AFPX-C14TD (NPN)
AFPX-C14PD (PNP)
AFPX-C14T (NPN)
AFPX-C14P (PNP)
8-point input of 24 V DC
6-point output of 2 A relay
8-point input of 24 V DC
6-point output of 2 A relay
8-point input of 24 V DC
0.5 A/5 to 24 V DC
6-point output of transistor
8-point input of 24 V DC
0.5 A/5 to 24 V DC
6-point output of transistor
DC power supply
AC power supply
DC power supply
AC power supply
AFPX-C30RD
AFPX-C30R
AFPX-C30TD (NPN)
AFPX-C30PD (PNP)
AFPX-C30T (NPN)
AFPX-C30P (PNP)
16-point input of 24 V DC
14-point output of 2 A relay
16-point input of 24 V DC
14-point output of 2 A relay
16-point input of 24 V DC
0.5 A/5 to 24 V DC
14-point output of transistor
16-point input of 24 V DC
0.5 A/5 to 24 V DC
14-point output of transistor
DC power supply
AC power supply
DC power supply
AC power supply
Program capacity: 16k steps
2-point potentiometer
Program capacity: 32k steps
2-point potentiometer, Equipped
with a USB communication port
(Model: Relay output type AFPX-C30R)
Connector for
add-on cassette
I/O status monitor LED
Connector for
expansion unit
USB communication port (excluding C14R)
RUN/PROG. mode selection switch
Connector
for battery
Potentiometer
RS232C tool port
Connector for expansion unit
24 V DC service power output terminals
C14: 0.15 A
C30, C60: 0.4 A
Output terminals
(DC powered type has no service power output)
Program capacity: 32k steps
4-point potentiometer, Equipped
with a USB communication port
AFPX-C60RD
AFPX-C60R
AFPX-C60TD (NPN)
AFPX-C60PD (PNP)
AFPX-C60T (NPN)
AFPX-C60P (PNP)
32-point input of 24 V DC
28-point output of 2 A relay
32-point input of 24 V DC
28-point output of 2 A relay
32-point input of 24 V DC
0.5 A/5 to 24 V DC
28-point output of transistor
32-point input of 24 V DC
0.5 A/5 to 24 V DC
28-point output of transistor
Expansion Unit
(Model: Relay output type AFPX-E16R)
Input terminals
Expansion Unit
AFPX-E16R
AFPX-E16T (NPN)
AFPX-E16P (PNP)
8-point input of 24 V DC
8-point output of 2 A relay
8-point input of 24 V DC
0.5 A/5 to 24 V DC
8-point output of transistor
Remarks: Two or more E16 can't be connected serially
because it can't supply the power to other units.
DC power supply
AC power supply
DC power supply
AC power supply
AFPX-E30RD
AFPX-E30R
AFPX-E30TD (NPN)
AFPX-E30PD (PNP)
AFPX-E30T (NPN)
AFPX-E30P (PNP)
16-point input of 24 V DC
14-point output of 2 A relay
16-point input of 24 V DC
14-point output of 2 A relay
16-point input of 24 V DC
0.5 A/5 to 24 V DC
14-point output of transistor
16-point input of 24 V DC
0.5 A/5 to 24 V DC
14-point output of transistor
I/O status monitor LED
Connector for expansion unit
Remarks: Addition of up to 8 units
is possible including E16 and EFP0.
Add-on
Cassette
Application cassette
W
NE
AFPX-IN4T3
Input /Output cassette (4-point input of 24 V DC,
NPN 0.3 A/3-point output of 24 V DC)
AFPX-IN8
Input cassette (8-point input of 24 V DC)
AFPX-TR8
Output cassette (NPN 0.3 A/8-point output of 24 V DC)
AFPX-TR6P
AFPX-PLS
Connector for expansion unit
Communication cassette
AFPX-COM1
Communication cassette (RS232C 1 ch.)
AFPX-COM2
Communication cassette (RS232C 2 ch.)
Output cassette (PNP 0.5 A/6-point output of 24 V DC)
AFPX-COM3
Communication cassette
(RS485/422 selectable 1 ch. insulated)
Pulse I/O cassette
(High-speed counter input: single phase 80 kHz 2 ch., 2-phase 30 kHz 1 ch.)
(Pulse output: 1 axis 100 kHz < CW/CCW, pulse + sign >)
AFPX-COM4
Communication cassette
(RS485 1 ch. insulated + RS232C 1 ch.)
Output terminals
Add-on Cassette
(Model: Analog input cassette AFPX-AD2)
Securing hole
*Cannot be built into s transistor output type.
AFPX-AD2
Analog input cassette (2 points, 0 to 10 V/0 to 20 mA 12-bit non-insulated)
AFPX-A21
Analog I/O cassette
Input: 2 ch. (0 to 5 V/0 to 10 V or 0 to 20 mA12-bit insulated)
Output: 1 ch. (0 to 10 V or 0 to 20 mA12-bit insulated)
EW
AFPX-DA2
Analog output cassette
2 ch. (0 to 10 V or 0 to 20 mA12-bit insulated 2 ch.)
W
AFPX-TC2
Thermocouple input cassette
(K/J type, Resolution: 0.2°C, insulated 2 ch.)
AFPX-MRTC
Master memory cassette with a real-time clock*
(32 k steps program memory +
real-time clock in year/month/day/hour/minute)
W
NE
N
NE
W
NE
AFPX-COM5
Communication cassette
(Ethernet 1 ch + RS232C 1 ch.)
Connector for double-stacked mounting
* Only the communication cassette can be upper.
W
NE
AFPX-COM6
* Use the two opposite diagonal holes
for mounting when a communication
cassette is double-stacked.
Communication cassette
(RS485 2 ch. insulated)
Expansion FP0 Adapter
Input/output terminals or communication signal terminals
*Real-time clock needs an option battery.
(Real-time clock → Calendar timer)
4
AFPX-EFP0
Up to 3 FP0 expansion units
can be connected.
Please refer to page 7 for details.
5
The Highly Expandable Lineup
Satisfies Wide Range of Demands.
FP-X Name and Function of Each Part
The flexible product lineup designed for rapidly responding
to user needs provides a high level of satisfaction.
Control Unit
Input terminals
Power terminals
Product Lineup
Control Unit
Relay output
Add-on cassette interface cover
Transistor output
DC power supply
AC power supply
DC power supply
AC power supply
AFPX-C14RD
AFPX-C14R
AFPX-C14TD (NPN)
AFPX-C14PD (PNP)
AFPX-C14T (NPN)
AFPX-C14P (PNP)
8-point input of 24 V DC
6-point output of 2 A relay
8-point input of 24 V DC
6-point output of 2 A relay
8-point input of 24 V DC
0.5 A/5 to 24 V DC
6-point output of transistor
8-point input of 24 V DC
0.5 A/5 to 24 V DC
6-point output of transistor
DC power supply
AC power supply
DC power supply
AC power supply
AFPX-C30RD
AFPX-C30R
AFPX-C30TD (NPN)
AFPX-C30PD (PNP)
AFPX-C30T (NPN)
AFPX-C30P (PNP)
16-point input of 24 V DC
14-point output of 2 A relay
16-point input of 24 V DC
14-point output of 2 A relay
16-point input of 24 V DC
0.5 A/5 to 24 V DC
14-point output of transistor
16-point input of 24 V DC
0.5 A/5 to 24 V DC
14-point output of transistor
DC power supply
AC power supply
DC power supply
AC power supply
Program capacity: 16k steps
2-point potentiometer
Program capacity: 32k steps
2-point potentiometer, Equipped
with a USB communication port
(Model: Relay output type AFPX-C30R)
Connector for
add-on cassette
I/O status monitor LED
Connector for
expansion unit
USB communication port (excluding C14R)
RUN/PROG. mode selection switch
Connector
for battery
Potentiometer
RS232C tool port
Connector for expansion unit
24 V DC service power output terminals
C14: 0.15 A
C30, C60: 0.4 A
Output terminals
(DC powered type has no service power output)
Program capacity: 32k steps
4-point potentiometer, Equipped
with a USB communication port
AFPX-C60RD
AFPX-C60R
AFPX-C60TD (NPN)
AFPX-C60PD (PNP)
AFPX-C60T (NPN)
AFPX-C60P (PNP)
32-point input of 24 V DC
28-point output of 2 A relay
32-point input of 24 V DC
28-point output of 2 A relay
32-point input of 24 V DC
0.5 A/5 to 24 V DC
28-point output of transistor
32-point input of 24 V DC
0.5 A/5 to 24 V DC
28-point output of transistor
Expansion Unit
(Model: Relay output type AFPX-E16R)
Input terminals
Expansion Unit
AFPX-E16R
AFPX-E16T (NPN)
AFPX-E16P (PNP)
8-point input of 24 V DC
8-point output of 2 A relay
8-point input of 24 V DC
0.5 A/5 to 24 V DC
8-point output of transistor
Remarks: Two or more E16 can't be connected serially
because it can't supply the power to other units.
DC power supply
AC power supply
DC power supply
AC power supply
AFPX-E30RD
AFPX-E30R
AFPX-E30TD (NPN)
AFPX-E30PD (PNP)
AFPX-E30T (NPN)
AFPX-E30P (PNP)
16-point input of 24 V DC
14-point output of 2 A relay
16-point input of 24 V DC
14-point output of 2 A relay
16-point input of 24 V DC
0.5 A/5 to 24 V DC
14-point output of transistor
16-point input of 24 V DC
0.5 A/5 to 24 V DC
14-point output of transistor
I/O status monitor LED
Connector for expansion unit
Remarks: Addition of up to 8 units
is possible including E16 and EFP0.
Add-on
Cassette
Application cassette
W
NE
AFPX-IN4T3
Input /Output cassette (4-point input of 24 V DC,
NPN 0.3 A/3-point output of 24 V DC)
AFPX-IN8
Input cassette (8-point input of 24 V DC)
AFPX-TR8
Output cassette (NPN 0.3 A/8-point output of 24 V DC)
AFPX-TR6P
AFPX-PLS
Connector for expansion unit
Communication cassette
AFPX-COM1
Communication cassette (RS232C 1 ch.)
AFPX-COM2
Communication cassette (RS232C 2 ch.)
Output cassette (PNP 0.5 A/6-point output of 24 V DC)
AFPX-COM3
Communication cassette
(RS485/422 selectable 1 ch. insulated)
Pulse I/O cassette
(High-speed counter input: single phase 80 kHz 2 ch., 2-phase 30 kHz 1 ch.)
(Pulse output: 1 axis 100 kHz < CW/CCW, pulse + sign >)
AFPX-COM4
Communication cassette
(RS485 1 ch. insulated + RS232C 1 ch.)
Output terminals
Add-on Cassette
(Model: Analog input cassette AFPX-AD2)
Securing hole
*Cannot be built into s transistor output type.
AFPX-AD2
Analog input cassette (2 points, 0 to 10 V/0 to 20 mA 12-bit non-insulated)
AFPX-A21
Analog I/O cassette
Input: 2 ch. (0 to 5 V/0 to 10 V or 0 to 20 mA12-bit insulated)
Output: 1 ch. (0 to 10 V or 0 to 20 mA12-bit insulated)
EW
AFPX-DA2
Analog output cassette
2 ch. (0 to 10 V or 0 to 20 mA12-bit insulated 2 ch.)
W
AFPX-TC2
Thermocouple input cassette
(K/J type, Resolution: 0.2°C, insulated 2 ch.)
AFPX-MRTC
Master memory cassette with a real-time clock*
(32 k steps program memory +
real-time clock in year/month/day/hour/minute)
W
NE
N
NE
W
NE
AFPX-COM5
Communication cassette
(Ethernet 1 ch + RS232C 1 ch.)
Connector for double-stacked mounting
* Only the communication cassette can be upper.
W
NE
AFPX-COM6
* Use the two opposite diagonal holes
for mounting when a communication
cassette is double-stacked.
Communication cassette
(RS485 2 ch. insulated)
Expansion FP0 Adapter
Input/output terminals or communication signal terminals
*Real-time clock needs an option battery.
(Real-time clock → Calendar timer)
4
AFPX-EFP0
Up to 3 FP0 expansion units
can be connected.
Please refer to page 7 for details.
5
Basic Performance (High capacity/High speed)
Basic Performance (Expansion)
The high-level basic performance provides sufficient room for future
■ Abundant number of I/O points - Maximum
equipment expansion as well as a rich variation.
■ Abundant program capacity -
300
(Up to 382 points possible by using FP0 expansion units and add-on cassettes)
When the user cannot predict the number of I/O points required in the future for his machine or equipment, he is
uncertain in selecting a PLC model. FP-X solves user concerns with a maximum of 300 I/O channels. The number
can even be increased up to 382 points by using the add-on cassettes and FP0 expansion units.
●Program capacity
32 ksteps (16 ksteps for C14)
FP-X
C30/C60
32k
C30, C60
The program capacity of 32 ksteps, exceeding the capacity of most compact PLCs,
can flexibly handle a wide variety of applications requiring future equipment
expansion. An adequate comment area has of course been reserved. Free comment
entry makes the program easy to understand during verification.
FP-X
● Expansion units (E16R, E30R, EFP0) can be connected up to eight units.
C14
16k
C14
C60
E30
E30
E30
FP0
Max. 300 channels
10k
10k
20k
30k
steps
Max. 8 units
■ Equipped with an independent comment memory
● Two or more E16 can't be connected serially. ● E16 can be sandwiched with E30*
Equipped with an independent comment memory separate from the program memory.
All of 100,000 I/O comments, 5,000 lines of line-space comments, and 5,000 lines
of remark comments are saved in FP-X together with programs.
C60
E16
E16
C60
E16
E30
*Input comments do not decrease the program capacity.
■ High-speed scan at
●Processing speed of the basic
instructions (ST, OR, AND, OT etc)
0.32 µsec for instruction processing
FP-X
0.32 µsec
C60
Specifications
Timer/counter (T/C)
Data register (DT)
Link data register (LD)
Special data register (DT)
Index register (I0 to ID)
Master control relay (MCR)
Number of labels (LOOP)
Number of differentiations
Number of stepladders
Number of subroutines
Number of interruption programs
High-speed counter
*2
12285 words (C14), 32765 words (C30, C60)
256 words
374 words
14 words
256 points
256 labels
Up to program capacity
1000 stages
500 subroutines
Relay output type: 15 programs (14 external, 1 constant)
Transistor output type: 9 programs (8 external, 1 constant)
Built-in (Transistor output): single-phase 8 ch (50 kHz x 4 ch + 10 kHz x 4 ch)
Built-in (Relay output): single-phase 8 ch (10 kHz x 8 ch)
Pulse I/O cassette *3: single-phase 2 ch (80 kHz x 2 ch)
*1 The actual usable number of points is restricted by the hardware.
*2 Specification at the rated input voltage of 24 V DC, 25°C. Frequency may be lower due to the voltage and
temperature. The countable frequency also changes depending on the number of channels used.
*3 The pulse I/O cassette cannot be used for the control units (transistor output type).
6
Item
Pulse catch input / interrupt input
Periodical interrupt
Potentiometer
Constant scan
Real-time clock
Flash ROM
backup *7
Specifications
Built-in (Transistor output): 100 kHz x 2 ch + 20 kHz x 2 ch
Pulse I/O cassette (for the relay output type only):
One unit (one axis) 100 kHz, or two units (two axes) 80 kHz
Pulse output *4
Backup by F12,
P13 commands
An 80-cm expansion cable is
also available as an option.
1.0 µsec
Controls Specifications
Total 1024 points: timer capable of counting
(1 ms, 10 ms, 100 ms, 1 s) x 32767
Counter capable of counting 1 to 32767
E30
FP0
0.5
Relay symbol method
Cyclic operation method
Flash ROM built-in (no battery backup required)
16 ksteps (C14), 32 ksteps (C30, C60)
Basic instruction 0.32 µs/step
111
216
1760 points *1
1760 points *1
4096 points
192 points
2048 points
E30
The units can be tightly
mounted adjacent to each
other with the cable bent
inside between the units for
saving space.
ms (measured time)
Program method
Control method
Program memory
Program capacity
Operation processing speed
Basic instructions
Applied instructions
External inputs (X)
External outputs (Y)
Internal relay (R)
Special internal relay (R)
Link relay (L)
* E30 requires an external power supply
0.9 µsec
(Ex.) In the case of a 5-kstep program consisting of 40% basic instructions
and 60% applied instructions (Data tansfer and operation instructions),
Item
OK
● Connection by using the cable included in each expansion unit.
High-speed processing is often required for small-scale equipment control
such as serial data communication, network construction or PID temperature
control. High-speed scanning at 0.32 µsec/step (basic instruction) easily meets
such requirements.
Scan time: 1.9
NG
Relay output type: Total 14 points (including the high-speed counter)
Transistor output type: Total 8 points (including the high-speed counter)
0.5 ms to 30 s
2 points (0 to 1000) (C14, C30) 4 points (0 to 1000) (C60)
Possible
Equipped (usable only when AFPX-MRTC is installed) *5
Note: Total expansion cable length: 160 cm max.
■ When further expansion or functions are required, use the existing
FP0 expansion unit.
All control units can be expanded by up to 3 FP0 expansion units via an adapter.
Applications can be expanded by using [Transistor outputs], [Analog input/outputs],
[Thermocouple input] and [I/O link (network)].
* Only one expansion FP0 adapter unit can be attached to a control unit.
Up to 7 FP-X expansion units can be used when the expansion FP0 adapter is attached.
C60
E30
E30
Data register (32765 words)
Counter 16 points (1008 to 1023), Internal relay 128 points
(R2480 to R255F), Data register 55 words
The memory allocated in the storage area by the
system register (only when a battery is installed) *6
Before installing C14: 1230 days (actual operation 10 years at 25°C)
AFPX-MRTC
C30, C60: 990 days (actual operation 10 years at 25°C)
C14: 780 days (actual operation 10 years at 25°C)
After installing
AFPX-MRTC
C30, C60: 680 days (actual operation 10 years at 25°C)
Auto-backup
at power failure
Battery backup
Battery life
(when no power is
supplied)
Password
Self-diagnosis function
Comment storage
PLC link function
Rewriting in RUN mode
(More than two batteries can be installed in C30 and C60.
In this case, the battery life is extended several times)
Capable (4 or 8 characters selectable)
Watch dog timer, program syntax check
Capable (328 KB) (backup battery not required)
All of I/O comments, remark comments, and line-space comments can be stored.
Max 16 units, link relay 1024 points, link register 128 words
(No data transfer or remote programming)
Capable
*4 Max frequency may vary by the method of operation. Please refer to the manual for details.
*5 Calendar accuracy at 0°C: 119 sec/month or less, 25°C: 51 sec/month or less, 55°C: 148 sec/month or
less (Real-time clock requires a battery.)
*6 When data is stored in the storage area while the battery is not installed, the data is not cleared and the
data value may be indefinite. The same condition occurs when the battery is exhausted.
*7 The number of possible rewrites is 10,000 or less.
Expansion FP0 adapter (AFPX-EFP0)
Max. 7 units (210 points)
Max. 96 points
In addition to the supplied 8-cm expansion cable, 30-cm and 80-cm types are available as options,
allowing the units to be arranged more freely. (Total expansion cable length: 160 cm max.)
Product number
FP0-E8X
FP0-E16X
FP0-E8YT
FP0-E8YRS
FP0-E16YT
FP0-E32T
FP0-E8RS
FP0-E16RS
Specifications
8 ch. DC input, MIL connector
16 ch. DC input, MIL connector
8 ch. transistor output, MIL connector
8 ch. relay output, screw terminal block
16 ch. transistor output, MIL connector
16 ch. DC input, 16 ch. transistor output,
MIL connector
4 ch. DC input, 4 ch. relay output,
screw terminal block
8 ch. DC input, 8 ch. relay output,
screw terminal block
We also have other units. Please refer to the part number
list at the end of this catalog.
Product number
Specifications
FP0-A21
FP0-A80
FP0-A04V
FP0-A04I
FP0-TC4
FP0-TC8
Analog 2 ch. input, 1 ch. output
Analog 8 ch. input
Analog (voltage) 4 ch. output
Analog (current) 4 ch. output
Thermocouple 4 ch. input
Thermocouple 8 ch. input
FP0-IOL
FP0-CCL
I/O link unit
CC-link unit
DC input, 16ch relay output
FP0-E32RS*2 16ch
screw terminal block
FP0-RTD6*2 6ch RTD input
FP0-DPS2*2 PROFIBUS remote I/O unit
The unified unit height of 90 mm makes
the panel surface look clean.
*2 Provided from Panasonic Electric Works Europe AG
7
Basic Performance (High capacity/High speed)
Basic Performance (Expansion)
The high-level basic performance provides sufficient room for future
■ Abundant number of I/O points - Maximum
equipment expansion as well as a rich variation.
■ Abundant program capacity -
300
(Up to 382 points possible by using FP0 expansion units and add-on cassettes)
When the user cannot predict the number of I/O points required in the future for his machine or equipment, he is
uncertain in selecting a PLC model. FP-X solves user concerns with a maximum of 300 I/O channels. The number
can even be increased up to 382 points by using the add-on cassettes and FP0 expansion units.
●Program capacity
32 ksteps (16 ksteps for C14)
FP-X
C30/C60
32k
C30, C60
The program capacity of 32 ksteps, exceeding the capacity of most compact PLCs,
can flexibly handle a wide variety of applications requiring future equipment
expansion. An adequate comment area has of course been reserved. Free comment
entry makes the program easy to understand during verification.
FP-X
● Expansion units (E16R, E30R, EFP0) can be connected up to eight units.
C14
16k
C14
C60
E30
E30
E30
FP0
Max. 300 channels
10k
10k
20k
30k
steps
Max. 8 units
■ Equipped with an independent comment memory
● Two or more E16 can't be connected serially. ● E16 can be sandwiched with E30*
Equipped with an independent comment memory separate from the program memory.
All of 100,000 I/O comments, 5,000 lines of line-space comments, and 5,000 lines
of remark comments are saved in FP-X together with programs.
C60
E16
E16
C60
E16
E30
*Input comments do not decrease the program capacity.
■ High-speed scan at
●Processing speed of the basic
instructions (ST, OR, AND, OT etc)
0.32 µsec for instruction processing
FP-X
0.32 µsec
C60
Specifications
Timer/counter (T/C)
Data register (DT)
Link data register (LD)
Special data register (DT)
Index register (I0 to ID)
Master control relay (MCR)
Number of labels (LOOP)
Number of differentiations
Number of stepladders
Number of subroutines
Number of interruption programs
High-speed counter
*2
12285 words (C14), 32765 words (C30, C60)
256 words
374 words
14 words
256 points
256 labels
Up to program capacity
1000 stages
500 subroutines
Relay output type: 15 programs (14 external, 1 constant)
Transistor output type: 9 programs (8 external, 1 constant)
Built-in (Transistor output): single-phase 8 ch (50 kHz x 4 ch + 10 kHz x 4 ch)
Built-in (Relay output): single-phase 8 ch (10 kHz x 8 ch)
Pulse I/O cassette *3: single-phase 2 ch (80 kHz x 2 ch)
*1 The actual usable number of points is restricted by the hardware.
*2 Specification at the rated input voltage of 24 V DC, 25°C. Frequency may be lower due to the voltage and
temperature. The countable frequency also changes depending on the number of channels used.
*3 The pulse I/O cassette cannot be used for the control units (transistor output type).
6
Item
Pulse catch input / interrupt input
Periodical interrupt
Potentiometer
Constant scan
Real-time clock
Flash ROM
backup *7
Specifications
Built-in (Transistor output): 100 kHz x 2 ch + 20 kHz x 2 ch
Pulse I/O cassette (for the relay output type only):
One unit (one axis) 100 kHz, or two units (two axes) 80 kHz
Pulse output *4
Backup by F12,
P13 commands
An 80-cm expansion cable is
also available as an option.
1.0 µsec
Controls Specifications
Total 1024 points: timer capable of counting
(1 ms, 10 ms, 100 ms, 1 s) x 32767
Counter capable of counting 1 to 32767
E30
FP0
0.5
Relay symbol method
Cyclic operation method
Flash ROM built-in (no battery backup required)
16 ksteps (C14), 32 ksteps (C30, C60)
Basic instruction 0.32 µs/step
111
216
1760 points *1
1760 points *1
4096 points
192 points
2048 points
E30
The units can be tightly
mounted adjacent to each
other with the cable bent
inside between the units for
saving space.
ms (measured time)
Program method
Control method
Program memory
Program capacity
Operation processing speed
Basic instructions
Applied instructions
External inputs (X)
External outputs (Y)
Internal relay (R)
Special internal relay (R)
Link relay (L)
* E30 requires an external power supply
0.9 µsec
(Ex.) In the case of a 5-kstep program consisting of 40% basic instructions
and 60% applied instructions (Data tansfer and operation instructions),
Item
OK
● Connection by using the cable included in each expansion unit.
High-speed processing is often required for small-scale equipment control
such as serial data communication, network construction or PID temperature
control. High-speed scanning at 0.32 µsec/step (basic instruction) easily meets
such requirements.
Scan time: 1.9
NG
Relay output type: Total 14 points (including the high-speed counter)
Transistor output type: Total 8 points (including the high-speed counter)
0.5 ms to 30 s
2 points (0 to 1000) (C14, C30) 4 points (0 to 1000) (C60)
Possible
Equipped (usable only when AFPX-MRTC is installed) *5
Note: Total expansion cable length: 160 cm max.
■ When further expansion or functions are required, use the existing
FP0 expansion unit.
All control units can be expanded by up to 3 FP0 expansion units via an adapter.
Applications can be expanded by using [Transistor outputs], [Analog input/outputs],
[Thermocouple input] and [I/O link (network)].
* Only one expansion FP0 adapter unit can be attached to a control unit.
Up to 7 FP-X expansion units can be used when the expansion FP0 adapter is attached.
C60
E30
E30
Data register (32765 words)
Counter 16 points (1008 to 1023), Internal relay 128 points
(R2480 to R255F), Data register 55 words
The memory allocated in the storage area by the
system register (only when a battery is installed) *6
Before installing C14: 1230 days (actual operation 10 years at 25°C)
AFPX-MRTC
C30, C60: 990 days (actual operation 10 years at 25°C)
C14: 780 days (actual operation 10 years at 25°C)
After installing
AFPX-MRTC
C30, C60: 680 days (actual operation 10 years at 25°C)
Auto-backup
at power failure
Battery backup
Battery life
(when no power is
supplied)
Password
Self-diagnosis function
Comment storage
PLC link function
Rewriting in RUN mode
(More than two batteries can be installed in C30 and C60.
In this case, the battery life is extended several times)
Capable (4 or 8 characters selectable)
Watch dog timer, program syntax check
Capable (328 KB) (backup battery not required)
All of I/O comments, remark comments, and line-space comments can be stored.
Max 16 units, link relay 1024 points, link register 128 words
(No data transfer or remote programming)
Capable
*4 Max frequency may vary by the method of operation. Please refer to the manual for details.
*5 Calendar accuracy at 0°C: 119 sec/month or less, 25°C: 51 sec/month or less, 55°C: 148 sec/month or
less (Real-time clock requires a battery.)
*6 When data is stored in the storage area while the battery is not installed, the data is not cleared and the
data value may be indefinite. The same condition occurs when the battery is exhausted.
*7 The number of possible rewrites is 10,000 or less.
Expansion FP0 adapter (AFPX-EFP0)
Max. 7 units (210 points)
Max. 96 points
In addition to the supplied 8-cm expansion cable, 30-cm and 80-cm types are available as options,
allowing the units to be arranged more freely. (Total expansion cable length: 160 cm max.)
Product number
FP0-E8X
FP0-E16X
FP0-E8YT
FP0-E8YRS
FP0-E16YT
FP0-E32T
FP0-E8RS
FP0-E16RS
Specifications
8 ch. DC input, MIL connector
16 ch. DC input, MIL connector
8 ch. transistor output, MIL connector
8 ch. relay output, screw terminal block
16 ch. transistor output, MIL connector
16 ch. DC input, 16 ch. transistor output,
MIL connector
4 ch. DC input, 4 ch. relay output,
screw terminal block
8 ch. DC input, 8 ch. relay output,
screw terminal block
We also have other units. Please refer to the part number
list at the end of this catalog.
Product number
Specifications
FP0-A21
FP0-A80
FP0-A04V
FP0-A04I
FP0-TC4
FP0-TC8
Analog 2 ch. input, 1 ch. output
Analog 8 ch. input
Analog (voltage) 4 ch. output
Analog (current) 4 ch. output
Thermocouple 4 ch. input
Thermocouple 8 ch. input
FP0-IOL
FP0-CCL
I/O link unit
CC-link unit
DC input, 16ch relay output
FP0-E32RS*2 16ch
screw terminal block
FP0-RTD6*2 6ch RTD input
FP0-DPS2*2 PROFIBUS remote I/O unit
The unified unit height of 90 mm makes
the panel surface look clean.
*2 Provided from Panasonic Electric Works Europe AG
7
Add-on Cassette (Lineup)
Add-on Cassette (Ethernet)
"Require slightly more functions", "Want to add functions to the existing equipment"
This Ethernet cassette meets user needs such as the "easy collection of inspection/
- The rich variety of add-on cassettes helps solve these requirements.
production data using LAN (Ethernet)" or "remote changing of ladder programs".
■ The
Add-on cassette easily adds small quantities of functions and I/O points.
■ The industry's first*1 add-on to equip a compact PLC with an Ethernet port
A: Available, N/A: Not available
*1: In Japan, as of May 1, 2007
AFPX-COM5
Attachable position (see the figure below)
Add-on Cassette
Part number
Specifications
A, lower A, upper
A
N/A
A
8-point input of 24 V DC, Bi-direction (Sink/Source)
A
N/A
A
AFPX-TR8
8-point output of 24 V DC, NPN transistor 0.3 A
A
N/A
A
AFPX-TR6P
6-point output of 24 V DC, PNP transistor 0.5 A
A
N/A
A
A
N/A
A
2-point analog input, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.
A
N/A
A
A
N/A
A
A
N/A
A
2-point thermocouple input, K/J type, Resolution: 0.2°C, 200 ms/2 ch., Channels insulated
A
N/A
A
32 k steps program memory + All comment saving/transfer, Calendar timer (Real-time clock)
A
N/A
A
AFPX-COM1
RS232C 1 ch.
A
A
N/A
AFPX-COM2
RS232C 2 ch.
A
A
N/A
AFPX-COM3
RS485/RS422 selectable 1 ch.
A
A
N/A
RS485 1 ch. + RS232C 1 ch.
A
A
N/A
I/O cassette
AFPX-IN4T3
Input cassette
AFPX-IN8
NE
W
Output cassette
C
3-point output of 24 V DC, NPN transistor 0.3 A
1. I/O control
2. Reading data from a tester (measuring instrument) of inspection equipment (RS232C)
3. Collecting the read data from the host computer (Ethernet)
4. Setting/monitoring by a touch panel (Tool port)
Ethernet RS232C
Pulse I/O cassette
(Cannot be used with a transistor
output type control unit.)
High-speed counter input: single phase 80 kHz 2 ch. or 2-phase 30 kHz 1 ch.
AFPX-PLS
Pulse output: 1 axis 100 kHz (CW/CCW, Pulse + Sign)
Analog input cassette
AFPX-AD2
Analog output cassette
AFPX-DA2
NE
W
2-point analog output, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.
Analog I/O cassette
NE
W
2-point analog input, 0 to 5 V, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.
AFPX-A21
Thermocouple input
cassette
AFPX-TC2
W
NE
Master memory cassette
(Only one cassette can be attached.)
Communication Cassette
(Only one of these cassettes
can be attached.)
1-point analog output, 0 to 10 V or 0 to 20 mA, 12-bit, 1 ms/1 ch.
AFPX-MRTC
AFPX-COM4
AFPX-COM5
NE
W
Ethernet 1 ch + RS232C 1 ch.
A
A
N/A
AFPX-COM6
NE
W
RS485 2 ch.
A
A
N/A
Only a backup battery can be attached.
Application Cassette
4-point input of 24 V DC, Bi-direction (Sink/Source)
B
● Enables easy Ethernet connections with a compact PLC, which have been previously abandoned.
● Also equipped with an RS232C port. Together with the tool port (programming port), a total of three
communication ports are available, which is remarkable for a compact PLC.
● For example, the following operations are simultaneously available with this cassette attached:
■ Application
Data collection
Operation data managing software
PCWAY
Ethernet
Tool port
Tool port
Tool port
RS232C
Touch
panel
RS232C
Touch
panel
Measuring
instrument
Remote maintenance
Program editing/monitoring
Measuring
instrument
Measuring
instrument
Programming software
FPWIN GR
FPWIN Pro
Max. number of attachable cassettes
Internet connection
Ethernet
C14
RS232C
Touch
panel
Ethernet
2 cassettes
C30, C60 3 cassettes
Easily removable
(Two screws to secure the unit)
■ Specifications
Interface
Attachment position (see the table above)
A, upper
A, upper
A, lower
A, lower
Ethernet
(COM1)
A, upper
B
A, lower
B
C
(Not attachable)
RS232C
(COM2)
C14
8
C30
C60
• Only section A has an upper side
available to attach the cassette.
• No add-on cassettes can be
attached to section C. Only a
backup battery can be attached.
Specifications and functions
Ethernet port functions
10BASE-T, 100BASE-TX, TCP/IP, Baud rate: 9600 bps/115200 bps
• Computer link (3 connections max.)
• General-purpose serial communications (1 connection max.)
→ Server function, client function
Computer link
3-wire (RD, SD, SG), Asynchronous, Baud rate: 300 bps to 115200 bps
• Computer link
• General-purpose serial communications
• Modbus-RTU master/slave
Generalpurpose
serial
communications
Specifications
• Automatically sends responses without communication programs
to commands of Matsushita's open protocol "MEWTOCOL".
• Contact/word data writing/reading, program editing
• PCWAY, FPWIN GR and FPWIN Pro are supported.
• Waits for a connection from a client PC (personal computer), and
Server
function after the connection is established, receives data from the PC.
• After the power is turned on, establishes a connection to a
Client
function preset IP address and sends data.
Use our free software "Configurator WD" for setting up
the Ethernet port (e.g. IP address and operation mode).
Download the software free of charge from:
http://www.mew.co.jp/ac/e
9
Add-on Cassette (Lineup)
Add-on Cassette (Ethernet)
"Require slightly more functions", "Want to add functions to the existing equipment"
This Ethernet cassette meets user needs such as the "easy collection of inspection/
- The rich variety of add-on cassettes helps solve these requirements.
production data using LAN (Ethernet)" or "remote changing of ladder programs".
■ The
Add-on cassette easily adds small quantities of functions and I/O points.
■ The industry's first*1 add-on to equip a compact PLC with an Ethernet port
A: Available, N/A: Not available
*1: In Japan, as of May 1, 2007
AFPX-COM5
Attachable position (see the figure below)
Add-on Cassette
Part number
Specifications
A, lower A, upper
A
N/A
A
8-point input of 24 V DC, Bi-direction (Sink/Source)
A
N/A
A
AFPX-TR8
8-point output of 24 V DC, NPN transistor 0.3 A
A
N/A
A
AFPX-TR6P
6-point output of 24 V DC, PNP transistor 0.5 A
A
N/A
A
A
N/A
A
2-point analog input, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.
A
N/A
A
A
N/A
A
A
N/A
A
2-point thermocouple input, K/J type, Resolution: 0.2°C, 200 ms/2 ch., Channels insulated
A
N/A
A
32 k steps program memory + All comment saving/transfer, Calendar timer (Real-time clock)
A
N/A
A
AFPX-COM1
RS232C 1 ch.
A
A
N/A
AFPX-COM2
RS232C 2 ch.
A
A
N/A
AFPX-COM3
RS485/RS422 selectable 1 ch.
A
A
N/A
RS485 1 ch. + RS232C 1 ch.
A
A
N/A
I/O cassette
AFPX-IN4T3
Input cassette
AFPX-IN8
NE
W
Output cassette
C
3-point output of 24 V DC, NPN transistor 0.3 A
1. I/O control
2. Reading data from a tester (measuring instrument) of inspection equipment (RS232C)
3. Collecting the read data from the host computer (Ethernet)
4. Setting/monitoring by a touch panel (Tool port)
Ethernet RS232C
Pulse I/O cassette
(Cannot be used with a transistor
output type control unit.)
High-speed counter input: single phase 80 kHz 2 ch. or 2-phase 30 kHz 1 ch.
AFPX-PLS
Pulse output: 1 axis 100 kHz (CW/CCW, Pulse + Sign)
Analog input cassette
AFPX-AD2
Analog output cassette
AFPX-DA2
NE
W
2-point analog output, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.
Analog I/O cassette
NE
W
2-point analog input, 0 to 5 V, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.
AFPX-A21
Thermocouple input
cassette
AFPX-TC2
W
NE
Master memory cassette
(Only one cassette can be attached.)
Communication Cassette
(Only one of these cassettes
can be attached.)
1-point analog output, 0 to 10 V or 0 to 20 mA, 12-bit, 1 ms/1 ch.
AFPX-MRTC
AFPX-COM4
AFPX-COM5
NE
W
Ethernet 1 ch + RS232C 1 ch.
A
A
N/A
AFPX-COM6
NE
W
RS485 2 ch.
A
A
N/A
Only a backup battery can be attached.
Application Cassette
4-point input of 24 V DC, Bi-direction (Sink/Source)
B
● Enables easy Ethernet connections with a compact PLC, which have been previously abandoned.
● Also equipped with an RS232C port. Together with the tool port (programming port), a total of three
communication ports are available, which is remarkable for a compact PLC.
● For example, the following operations are simultaneously available with this cassette attached:
■ Application
Data collection
Operation data managing software
PCWAY
Ethernet
Tool port
Tool port
Tool port
RS232C
Touch
panel
RS232C
Touch
panel
Measuring
instrument
Remote maintenance
Program editing/monitoring
Measuring
instrument
Measuring
instrument
Programming software
FPWIN GR
FPWIN Pro
Max. number of attachable cassettes
Internet connection
Ethernet
C14
RS232C
Touch
panel
Ethernet
2 cassettes
C30, C60 3 cassettes
Easily removable
(Two screws to secure the unit)
■ Specifications
Interface
Attachment position (see the table above)
A, upper
A, upper
A, lower
A, lower
Ethernet
(COM1)
A, upper
B
A, lower
B
C
(Not attachable)
RS232C
(COM2)
C14
8
C30
C60
• Only section A has an upper side
available to attach the cassette.
• No add-on cassettes can be
attached to section C. Only a
backup battery can be attached.
Specifications and functions
Ethernet port functions
10BASE-T, 100BASE-TX, TCP/IP, Baud rate: 9600 bps/115200 bps
• Computer link (3 connections max.)
• General-purpose serial communications (1 connection max.)
→ Server function, client function
Computer link
3-wire (RD, SD, SG), Asynchronous, Baud rate: 300 bps to 115200 bps
• Computer link
• General-purpose serial communications
• Modbus-RTU master/slave
Generalpurpose
serial
communications
Specifications
• Automatically sends responses without communication programs
to commands of Matsushita's open protocol "MEWTOCOL".
• Contact/word data writing/reading, program editing
• PCWAY, FPWIN GR and FPWIN Pro are supported.
• Waits for a connection from a client PC (personal computer), and
Server
function after the connection is established, receives data from the PC.
• After the power is turned on, establishes a connection to a
Client
function preset IP address and sends data.
Use our free software "Configurator WD" for setting up
the Ethernet port (e.g. IP address and operation mode).
Download the software free of charge from:
http://www.mew.co.jp/ac/e
9
Positioning
Temperature Control
FP-X perfectly fits the need for low cost “multi-axis positioning control
The high-level PID control easily achieves high-speed, high-accuracy
in small-scale equipment”
multi-point temperature control.
■ Built-in 4-axis Pulse Output (Transistor Output Type)
■ New PID Command (F356 EZPID) Produces a Temperature
Control Program only in a Single Line.
The transistor output type C14 comes with 3-axis while C30/C60 comes with 4-axis
pulse output inside the control unit. The multi-axis control, which previously
required a higher-level PLC or additional positioning unit, or two or more PLC units,
can now be achieved with only one FP-X transistor output type unit in a small
space at a low cost. In addition, as this type does not require a pulse I/O cassette
needed for a relay output type, other function expansion cassettes such as
communication or analog input can be attached for more diversified applications.
XY Table + Processing Head
Item
Specification
Pulse Output
C14: 100kHz(CH0,1), 20kHz(CH2)
Max Frequency C30,C60: 100kHz(CH0,1), 20kHz(CH2,3)
Output Type
Function
Semiconductor Wafer Takeout Blade
CW/CCW, Pulse + Direction Output
Trapezoidal control, multi-stage
operation, jog operation, origin return,
2-axis linear interpolation
● The relay output type can control two axes by
using the expansion cassettes
Pulse output up to 2-axis
80kHz is possible by
loading two pulse I/O
cassettes (AFPX-PLS).
Also capable of
performing 2-axis linear
interpolation.
100kHz x
2 axes
20kHz x
2 axes
3-axis Control with C14.
First
axis
80kHz
4-axis Control with C30/C60
Second
axis
80kHz
■ 2-axis Linear Interpolation Simultaneously in two Sets (Transistor Output Type)
Remark)
Pulse I/O cassette doesn’t work
with control unit transistor output
type.
C30/C60
Maximum
Y-axis composite speed
(CH3) 20kHz
X-axis
(CH2)
X-axis (CH0)
● The relay output type is also capable of 2-axis linear interpolation.
By adding two pulse I/O cassettes (AFPX-PLS), linear
interpolation is possible at the maximum composite speed of
80kHz. The command used for this unit is F175 (SPSH), same
as that for the transistor output types.
■ High-Speed Counters – Eight Built–in Sets
Eight single-phase or four dual-phase
sets (X0~X7)
Model Type
Transistor
output type
Input Mode
Single Phase
Dual Phase
Relay output
type
Single Phase
Dual Phase
°C
Touch Panel
Parameter setup
• Target value
• Control code
• PID control elements
Auto-tuning setup
• Target value setup
• Auto-tuning execution
Start bit ON
Auto-tuning end
Program
Start bit OFF
Parameter storage
Constant Temperature
Executing F356 PID command
PID command execution
Bit processing
SSR
Heater
Only a
single line
PWM output
frequency setup
Timer set value
conversion
t
PWM output
R0
PWM output circuit
WX1,
DT0,
DT100
Control code Measured value Target value Output value
●High-accuracy PID control is possible by adopting a sophisticated
algorithm and floating-point operations.
●Higher accuracy is obtained by ultra high-speed computations in a
32 µs/loop. For example, a 16-loop control only adds a scan time of
0.5 ms by ensuring minimum impact on the tact time.
●The simultaneous multi-point auto-tuning simplifies complex
parameter setting.
●The high-speed control PI-D*1 mode and overshoot suppression I-PD*2
mode are available for selection according to the intended application.
●By combining with a sequence control, the parameters (Kp, Ti, Td, etc.)
can be changed during a PID control execution, thereby enabling
optimum temperature control in each stage including start up, midrange, and convergence.
The ability to change the target value easily enables multi-step
temperature control, which was difficult only with temperature
controllers. In addition, the multi-point temperature control enables
the centralized control of multiple temperature controllers with a
single FP-X for unified data management.
Output address
Modbus-RTU
Multiple temperature
controllers
Easy unification of
data management
FP-X
T/C
T/C
T/C
T/C
T/C
The number can even be increased up to 28 channels by using
the thermocouple input cassette and FP0 thermocouple unit.
*1 Derivative type
*2 Proportional-derivative type
Pulse Output (four axes) One ch in use
Y0
F356 EZPID, WR1,
■ Multi-point PID control
Controls Two Units of 2-axis XY Table
Y-axis Maximum
(CH1) composite speed
100kHz
Thermocouple
When using the new
F356 PID command
When using the
previous F355 command
PWM output
2-axis linear interpolation refers to moving a robot arm or equipment head diagonally on a straight line by
simultaneously controlling two motor shafts. It is used for palletizing, component pick and place, XY table
control, contour cutting of a PC board etc. FP-X transistor output type is capable of simultaneously
controlling 2-axis linear interpolation, for the first time in the industry with a compact pulse-output PLC.
This unit drastically expands the range of applications along with the added convenience of programming
by using the linear interpolation commands F175 (SPSH).
Simultaneous Control of Two Mechanisms
●The application of PLC-based temperature control has been
expanding such as multi-level temperature control, timercontrolled temperature control, and a temperature control
relative to a variable based on a data computation results
etc. By using the new PID command (F356 EZPID), a PID
control program can be drastically simplified and the PLCbased temperature control, which was previously thought
to be difficult by a PLC, can easily be achieved. The
example on the right, a simple uniform temperature control,
enables a surprisingly easily PID control with a single line
command by using a F356 command combined with a
touch-panel operation.
All channels in use
During Halt
100kHz
50kHz × 4ch + 10kHz × 4ch
During Operation
35kHz
25kHz × 4ch + 10kHz × 4ch
During Halt
35kHz
25kHz × 2ch + 5kHz × 2ch
During Operation
15kHz
10kHz × 2ch + 5kHz × 2ch
During Halt
10kHz
10kHz × 8ch
During Operation
10kHz
10kHz × 8ch
During Halt
5kHz
5kHz × 4ch
During Operation
5kHz
5kHz × 4ch
Two modes are selectable
Partial optimum control by changing parameters
Multi-step control by changing the target value
High-speed PID
control
PI-D mode
Target value
Target
value
Target
value
Overshoot suppression
I-PD mode
Rapid acceleration
Smooth startup
When adding a pulse I/O cassette to the relay output type, two high-speed counter sets can
be added to every cassette. Please refer to the user manual for counter specification.
10
Time
Time
Time
11
Positioning
Temperature Control
FP-X perfectly fits the need for low cost “multi-axis positioning control
The high-level PID control easily achieves high-speed, high-accuracy
in small-scale equipment”
multi-point temperature control.
■ Built-in 4-axis Pulse Output (Transistor Output Type)
■ New PID Command (F356 EZPID) Produces a Temperature
Control Program only in a Single Line.
The transistor output type C14 comes with 3-axis while C30/C60 comes with 4-axis
pulse output inside the control unit. The multi-axis control, which previously
required a higher-level PLC or additional positioning unit, or two or more PLC units,
can now be achieved with only one FP-X transistor output type unit in a small
space at a low cost. In addition, as this type does not require a pulse I/O cassette
needed for a relay output type, other function expansion cassettes such as
communication or analog input can be attached for more diversified applications.
XY Table + Processing Head
Item
Specification
Pulse Output
C14: 100kHz(CH0,1), 20kHz(CH2)
Max Frequency C30,C60: 100kHz(CH0,1), 20kHz(CH2,3)
Output Type
Function
Semiconductor Wafer Takeout Blade
CW/CCW, Pulse + Direction Output
Trapezoidal control, multi-stage
operation, jog operation, origin return,
2-axis linear interpolation
● The relay output type can control two axes by
using the expansion cassettes
Pulse output up to 2-axis
80kHz is possible by
loading two pulse I/O
cassettes (AFPX-PLS).
Also capable of
performing 2-axis linear
interpolation.
100kHz x
2 axes
20kHz x
2 axes
3-axis Control with C14.
First
axis
80kHz
4-axis Control with C30/C60
Second
axis
80kHz
■ 2-axis Linear Interpolation Simultaneously in two Sets (Transistor Output Type)
Remark)
Pulse I/O cassette doesn’t work
with control unit transistor output
type.
C30/C60
Maximum
Y-axis composite speed
(CH3) 20kHz
X-axis
(CH2)
X-axis (CH0)
● The relay output type is also capable of 2-axis linear interpolation.
By adding two pulse I/O cassettes (AFPX-PLS), linear
interpolation is possible at the maximum composite speed of
80kHz. The command used for this unit is F175 (SPSH), same
as that for the transistor output types.
■ High-Speed Counters – Eight Built–in Sets
Eight single-phase or four dual-phase
sets (X0~X7)
Model Type
Transistor
output type
Input Mode
Single Phase
Dual Phase
Relay output
type
Single Phase
Dual Phase
°C
Touch Panel
Parameter setup
• Target value
• Control code
• PID control elements
Auto-tuning setup
• Target value setup
• Auto-tuning execution
Start bit ON
Auto-tuning end
Program
Start bit OFF
Parameter storage
Constant Temperature
Executing F356 PID command
PID command execution
Bit processing
SSR
Heater
Only a
single line
PWM output
frequency setup
Timer set value
conversion
t
PWM output
R0
PWM output circuit
WX1,
DT0,
DT100
Control code Measured value Target value Output value
●High-accuracy PID control is possible by adopting a sophisticated
algorithm and floating-point operations.
●Higher accuracy is obtained by ultra high-speed computations in a
32 µs/loop. For example, a 16-loop control only adds a scan time of
0.5 ms by ensuring minimum impact on the tact time.
●The simultaneous multi-point auto-tuning simplifies complex
parameter setting.
●The high-speed control PI-D*1 mode and overshoot suppression I-PD*2
mode are available for selection according to the intended application.
●By combining with a sequence control, the parameters (Kp, Ti, Td, etc.)
can be changed during a PID control execution, thereby enabling
optimum temperature control in each stage including start up, midrange, and convergence.
The ability to change the target value easily enables multi-step
temperature control, which was difficult only with temperature
controllers. In addition, the multi-point temperature control enables
the centralized control of multiple temperature controllers with a
single FP-X for unified data management.
Output address
Modbus-RTU
Multiple temperature
controllers
Easy unification of
data management
FP-X
T/C
T/C
T/C
T/C
T/C
The number can even be increased up to 28 channels by using
the thermocouple input cassette and FP0 thermocouple unit.
*1 Derivative type
*2 Proportional-derivative type
Pulse Output (four axes) One ch in use
Y0
F356 EZPID, WR1,
■ Multi-point PID control
Controls Two Units of 2-axis XY Table
Y-axis Maximum
(CH1) composite speed
100kHz
Thermocouple
When using the new
F356 PID command
When using the
previous F355 command
PWM output
2-axis linear interpolation refers to moving a robot arm or equipment head diagonally on a straight line by
simultaneously controlling two motor shafts. It is used for palletizing, component pick and place, XY table
control, contour cutting of a PC board etc. FP-X transistor output type is capable of simultaneously
controlling 2-axis linear interpolation, for the first time in the industry with a compact pulse-output PLC.
This unit drastically expands the range of applications along with the added convenience of programming
by using the linear interpolation commands F175 (SPSH).
Simultaneous Control of Two Mechanisms
●The application of PLC-based temperature control has been
expanding such as multi-level temperature control, timercontrolled temperature control, and a temperature control
relative to a variable based on a data computation results
etc. By using the new PID command (F356 EZPID), a PID
control program can be drastically simplified and the PLCbased temperature control, which was previously thought
to be difficult by a PLC, can easily be achieved. The
example on the right, a simple uniform temperature control,
enables a surprisingly easily PID control with a single line
command by using a F356 command combined with a
touch-panel operation.
All channels in use
During Halt
100kHz
50kHz × 4ch + 10kHz × 4ch
During Operation
35kHz
25kHz × 4ch + 10kHz × 4ch
During Halt
35kHz
25kHz × 2ch + 5kHz × 2ch
During Operation
15kHz
10kHz × 2ch + 5kHz × 2ch
During Halt
10kHz
10kHz × 8ch
During Operation
10kHz
10kHz × 8ch
During Halt
5kHz
5kHz × 4ch
During Operation
5kHz
5kHz × 4ch
Two modes are selectable
Partial optimum control by changing parameters
Multi-step control by changing the target value
High-speed PID
control
PI-D mode
Target value
Target
value
Target
value
Overshoot suppression
I-PD mode
Rapid acceleration
Smooth startup
When adding a pulse I/O cassette to the relay output type, two high-speed counter sets can
be added to every cassette. Please refer to the user manual for counter specification.
10
Time
Time
Time
11
Network
Network
The compact body can be equipped with up to three communication ports,
■ PLC Link (MEWNET-W0)
allowing for links to a wide variety of equipment.
Bit data/word data can be shared (linked) among up to 16 FP-X
units. This is ideal for linking adjacent equipment in a distributed
control system.
■ up to 3 communication ports
With a communication cassette (two-channel type), FP-X can be equipped with up to three communication ports although
the body size is small.
The combination of RS232C, RS485, Ethernet, and USB interfaces enables communications with a variety of equipment.
Communication cassette (two-channel type)
AFPX-COM2 (RS232C + RS232C)
AFPX-COM4 (RS485 + RS232C)
AFPX-COM5 (Ethernet + RS232C)
COM1: RS232C, RS485, Ethernet
COM2: RS232C, RS485, USB (The cassette port and the USB port cannot be used simultaneously.)
Tool port: RS232C
115.2 kbps
Transmission distance
1200 m
Shared data
128 words (data register), 64 words (contacts)
Communication method Floating master
16 stations, 115.2 kbps, 1200 m
Twisted-pair cable
See
page 9
for
details
Operation data managing software
PCWAY
Ethernet
Tool port
Tool port
Tool port
Touch
panel
RS232C
Touch
panel
Measuring
instrument
Responses
• Tool port
• COM1
• COM2
All are compatible with the
computer link.
Simultaneous communications
via the three ports are possible.
• Programming software
FPWIN GR/FPWIN Pro
• Operation data managing
software
PCWAY
Touch panel
Image processing device
GT Series
PV310
■ General-purpose Serial Communications
RS232C
RS232C
MEWTOCOL master stations
Commands
Data collection
General-purpose serial communications include the following two types.
1. FP-X, as a master, sends commands and receives responses in accordance with the protocol designated by the slave unit.
2. FP-X, as a slave, receives data sent from the master unit as is.
Measuring
instrument
■ Modbus-RTU* Compatibility
FP-X (master)
FP-X (slave)
Commands
Data
(nonprocedural)
Compatible with both the master and slave of the Modbus* RTU, the world's de-facto standard.
Great performance is expected for air-conditioning, temperature controls etc.
Responses
* Protocol developed by the Modicon Inc. of the United States
Can also be used as
a slave station
Inverter
Another available application
When 17 or more FP-X units need to be linked, the use of a Modbus
instead of a MEWNET-W0 (See following page.) can accommodate up to
99 FP-X units. Because each FP-X can be a master or slave, a multimaster link can be constructed by passing a token from a user program.
FP2
FP-e
2D code reading sensor
PD60/PD65
Printer, etc
Usable as a master station [F145 (SEND), F146 (RECV) commands]
Capable of easily communicating with a temperature controller, inverter, FP-e, and foreign PLC
12
Transmission speed
■ Computer link (MEWTOCOL slave)
FP-X (slave)
With an AFPX-COM5 communication cassette (Ethernet type), FP-X data can be easily collected using a
host PC through a LAN. This cassette is also equipped with one RS232C channel, also facilitating data
collection from a tester (measuring instrument). This is an ideal Ethernet terminal for I/O control.
Temperature Watt-hour meter
controller
16 stations
The computer link provides command-response communications using Matsushita's open protocol "MEWTOCOL".
When the FP-X communication port is set to the computer link mode, FP-X, as a slave, automatically sends
responses to MEWTOCOL commands sent from a master station, such as a personal computer.
■ Ethernet
Measuring
instrument
Specifications
Number of stations
FP-X requires a communication cassette (AFPX-COM3, AFPX-COM4
or AFPX-COM6)
FP2/FP2SH requires a multi-communication unit (AFP2465, AFP2805)
FPΣ requires a communication cassette (AFPG803, AFPG806)
AFPX-COM6 (RS485 + RS485)
Touch
panel
Item
●Links with our other PLCs (FPΣ, FP2/FP2SH) are possible.
●Simple setting of the number of linked units, linked relays, and
starting area address of the own station by using FPWIN GR/Pro
allows sharing of contact information and data without
programming.
●The transfer rate of 115.2 kbps, the highest rate for a compact
model.
●A transfer distance of 1200 m, the longest distance for a
compact model.
RS485
●FP-X and FPΣ allow a change of the station number by
programming (SYS instruction).
FPΣ
• Tool port
• COM1
• COM2
All are compatible with
general-purpose serial
communications. (Tool port:
Only in the RUN mode)
Simultaneous communications
via the three ports are possible.
Measuring
instrument
When FP-X, as a master, sends commands to MEWTOCOL-compatible equipment during
Useful
general-purpose serial communications, the commands can be easily
function
generated/transmitted by using the MEWTOCOL master instructions (F145 and F146).
FP-X (master)
MEWTOCOL commands
(generated by F145 and F146)
Token passing (by user program)
Responses
Master/
slave
Master/
slave
Master/
slave
Master/
slave
Multi-master link of up
to 99 units is possible.
Temperature
controller
KT4H
Eco-POWER METER
KW4M
13
Network
Network
The compact body can be equipped with up to three communication ports,
■ PLC Link (MEWNET-W0)
allowing for links to a wide variety of equipment.
Bit data/word data can be shared (linked) among up to 16 FP-X
units. This is ideal for linking adjacent equipment in a distributed
control system.
■ up to 3 communication ports
With a communication cassette (two-channel type), FP-X can be equipped with up to three communication ports although
the body size is small.
The combination of RS232C, RS485, Ethernet, and USB interfaces enables communications with a variety of equipment.
Communication cassette (two-channel type)
AFPX-COM2 (RS232C + RS232C)
AFPX-COM4 (RS485 + RS232C)
AFPX-COM5 (Ethernet + RS232C)
COM1: RS232C, RS485, Ethernet
COM2: RS232C, RS485, USB (The cassette port and the USB port cannot be used simultaneously.)
Tool port: RS232C
115.2 kbps
Transmission distance
1200 m
Shared data
128 words (data register), 64 words (contacts)
Communication method Floating master
16 stations, 115.2 kbps, 1200 m
Twisted-pair cable
See
page 9
for
details
Operation data managing software
PCWAY
Ethernet
Tool port
Tool port
Tool port
Touch
panel
RS232C
Touch
panel
Measuring
instrument
Responses
• Tool port
• COM1
• COM2
All are compatible with the
computer link.
Simultaneous communications
via the three ports are possible.
• Programming software
FPWIN GR/FPWIN Pro
• Operation data managing
software
PCWAY
Touch panel
Image processing device
GT Series
PV310
■ General-purpose Serial Communications
RS232C
RS232C
MEWTOCOL master stations
Commands
Data collection
General-purpose serial communications include the following two types.
1. FP-X, as a master, sends commands and receives responses in accordance with the protocol designated by the slave unit.
2. FP-X, as a slave, receives data sent from the master unit as is.
Measuring
instrument
■ Modbus-RTU* Compatibility
FP-X (master)
FP-X (slave)
Commands
Data
(nonprocedural)
Compatible with both the master and slave of the Modbus* RTU, the world's de-facto standard.
Great performance is expected for air-conditioning, temperature controls etc.
Responses
* Protocol developed by the Modicon Inc. of the United States
Can also be used as
a slave station
Inverter
Another available application
When 17 or more FP-X units need to be linked, the use of a Modbus
instead of a MEWNET-W0 (See following page.) can accommodate up to
99 FP-X units. Because each FP-X can be a master or slave, a multimaster link can be constructed by passing a token from a user program.
FP2
FP-e
2D code reading sensor
PD60/PD65
Printer, etc
Usable as a master station [F145 (SEND), F146 (RECV) commands]
Capable of easily communicating with a temperature controller, inverter, FP-e, and foreign PLC
12
Transmission speed
■ Computer link (MEWTOCOL slave)
FP-X (slave)
With an AFPX-COM5 communication cassette (Ethernet type), FP-X data can be easily collected using a
host PC through a LAN. This cassette is also equipped with one RS232C channel, also facilitating data
collection from a tester (measuring instrument). This is an ideal Ethernet terminal for I/O control.
Temperature Watt-hour meter
controller
16 stations
The computer link provides command-response communications using Matsushita's open protocol "MEWTOCOL".
When the FP-X communication port is set to the computer link mode, FP-X, as a slave, automatically sends
responses to MEWTOCOL commands sent from a master station, such as a personal computer.
■ Ethernet
Measuring
instrument
Specifications
Number of stations
FP-X requires a communication cassette (AFPX-COM3, AFPX-COM4
or AFPX-COM6)
FP2/FP2SH requires a multi-communication unit (AFP2465, AFP2805)
FPΣ requires a communication cassette (AFPG803, AFPG806)
AFPX-COM6 (RS485 + RS485)
Touch
panel
Item
●Links with our other PLCs (FPΣ, FP2/FP2SH) are possible.
●Simple setting of the number of linked units, linked relays, and
starting area address of the own station by using FPWIN GR/Pro
allows sharing of contact information and data without
programming.
●The transfer rate of 115.2 kbps, the highest rate for a compact
model.
●A transfer distance of 1200 m, the longest distance for a
compact model.
RS485
●FP-X and FPΣ allow a change of the station number by
programming (SYS instruction).
FPΣ
• Tool port
• COM1
• COM2
All are compatible with
general-purpose serial
communications. (Tool port:
Only in the RUN mode)
Simultaneous communications
via the three ports are possible.
Measuring
instrument
When FP-X, as a master, sends commands to MEWTOCOL-compatible equipment during
Useful
general-purpose serial communications, the commands can be easily
function
generated/transmitted by using the MEWTOCOL master instructions (F145 and F146).
FP-X (master)
MEWTOCOL commands
(generated by F145 and F146)
Token passing (by user program)
Responses
Master/
slave
Master/
slave
Master/
slave
Master/
slave
Multi-master link of up
to 99 units is possible.
Temperature
controller
KT4H
Eco-POWER METER
KW4M
13
Other Useful Functions
Other Useful Functions
High versatility and rich functionality provides “peace of mind” and “flexibility”.
The enhanced functionality expands the ranges of applications,
while improving the ease of use.
■ An expensive USB conversion adapter/cable is not necessary for connecting
a PC to the PLC by using a standard USB port.*
In the case of FP-X
Before
PC
RS232C/422 Previous Model
conversion
adapter
USB
conversion cable
* USB port is equipped with C30 and C60.
C30 and C60 control units have a
USB port as standard equipment.
They can be easily connected to a
PC with a commercially available
USB cable (AB type), making
program editing/monitoring
available. It is no longer
necessary to bring a dedicated
cable to remote locations.
AFPX-C30/C60
PC
■ Securing 0.5A in every transistor output even when all output ports are ON.
USB cable direct
connection
The conventional
RS232C port can also be used.
The transistor output type is not limited by the control capacity of each common
line. Every output port can secure 0.5A even when all output ports are ON for any
basic unit C14, C30, C60 as well as the expansion units E16 and E30 (at 25°C) –
Sufficient capacity for high-load switching such as LED type signal tower etc.
LED signal tower
Transistor Output Capacity 0.5A
(Even when all output ports are ON)
■ The master memory makes a program transfer easy and a real-time clock is equipped also
■ Equipped with a sampling trace function – Smart solution for program debugging
●The built-in 512 KB flash-ROM can store a 32-kstep
program as well as the comments and FPWIN Pro source
file.
●Program update in a remote location is easy by simply
sending master memory for local installation.
●As the master memory stores the password information,
password protection can be applied for program
transmission. Similarly, upload prohibition/permission
can be setup.
●The built-in real-time clock enables periodical repeated
control and periodical data logging.
The sampling trace function enables the user to monitor a change of I/O condition
or data register value in a very short time interval – an efficiency tool for debugging
a ladder program.
(Available from Ver. 2.0 of the transistor type and relay output types)
To the field
operation
Master memory
Program
transfer
FPWIN GR/Pro
FP-X
Password used ➔ Password locked
Upload prohibited set ➔ Upload prohibited
Program
transfer
FP-X
Upload prohibited not set ➔ Upload permitted
The shortest sampling interval of the normal time-chart monitor is 10ms with the
FPWIN GR or FPWIN Pro, but monitoring in much shorter intervals is often required
during debugging operations. The sampling trace function enables data
accumulation of any 16 contact data and 3 data register values once or several
times within a scan time. Reading out these data through the FPWIN GR or FPWIN
Pro enables the user to confirm an instantaneous change of status by time on the
time-chart monitor.
(Normal Time-Chart Monitor)
■ Programs can be saved without a backup battery, making maintenance easier.
(Sampling Trace)
●The programs and comments are stored in flash-ROM,
requiring no backup batteries.
●A backup battery (AFPX-BATT) is provided for data and
real-time clock.
One battery for C14, two for C30 and three for C60 can be
attached. A two-battery installation can operate for a long
time (10 years or more) without maintenance. (Real-time
clock doesn't work without a battery.)
Battery
holder
Connector
Backup battery
for FP-X
(AFPX-BATT)
Invisible changes become visible!
Protects your important program by preventing illegal copies
■ F-ROM data saving (Data can be saved without a battery.)
●FP-X can store a program, comments, a total of 55 words
of data, and bit setting values in a flash memory without
a battery. All of the data and bits can be stored by
adding optional batteries, but writing into a flash-ROM is
possible without a battery by using applied instructions
(F12, P13). Perfectly suited for data storage of the setup
values and recipes modified several times a day.
* The limitation in a flash-ROM designates the number of rewrites to be 10,000, or the
feasible number to be approx 30,000. However, rewriting every second will generate a
memory failure within a few hours.
R9013
Reading
Flash-ROM
Writing
■ Program upload is easily prohibited by tool software FPWIN.
F12 ICRD K0, K1, DT0
During the first scan, read one block
(2048 words) from the starting address of
DT0 at block number 0.
R0
P13 ICWD DT0, K1, K0
When R0 is turned on, write one block
(2048 words) starting from the address
DT0 at block number 0.
●Reading a program from the PLC main unit is virtually impossible.
●In the upload-prohibited condition, program transfers to the master
memory are also prohibited.
●Release of an upload-prohibited condition is possible with a forced
release accompanied by a program deletion.
●Program updates are easily carried out by transferring the program in
the master memory to FP-X even during an upload-prohibited condition.
The transferred program in FP-X is setup with the same upload
prohibition and permission conditions used in the master memory.
Protected
Protected
Master memory
14
Program download from a PC
Data transfer from the master
Forced input/output
(Original program is required)
Items possible
memory
Ladder monitor
during an upload- Change of data monitor/resistor value (Original program is required)
prohibited condition Contact monitor
Rewrite during RUN mode
Time chart monitor
Items impossible Program upload to a PC
during an upload- Data transfer to the master memory
prohibited condition
(Original program is required)
Password protection
■ More secure eight-character password can be used
along with the previous four-character password.
●The combination of upper and lower case alphanumeric
characters produces 218 trillion combinations. In addition,
after three consecutive entry failures, a power reset is
required for password release.
15
Other Useful Functions
Other Useful Functions
High versatility and rich functionality provides “peace of mind” and “flexibility”.
The enhanced functionality expands the ranges of applications,
while improving the ease of use.
■ An expensive USB conversion adapter/cable is not necessary for connecting
a PC to the PLC by using a standard USB port.*
In the case of FP-X
Before
PC
RS232C/422 Previous Model
conversion
adapter
USB
conversion cable
* USB port is equipped with C30 and C60.
C30 and C60 control units have a
USB port as standard equipment.
They can be easily connected to a
PC with a commercially available
USB cable (AB type), making
program editing/monitoring
available. It is no longer
necessary to bring a dedicated
cable to remote locations.
AFPX-C30/C60
PC
■ Securing 0.5A in every transistor output even when all output ports are ON.
USB cable direct
connection
The conventional
RS232C port can also be used.
The transistor output type is not limited by the control capacity of each common
line. Every output port can secure 0.5A even when all output ports are ON for any
basic unit C14, C30, C60 as well as the expansion units E16 and E30 (at 25°C) –
Sufficient capacity for high-load switching such as LED type signal tower etc.
LED signal tower
Transistor Output Capacity 0.5A
(Even when all output ports are ON)
■ The master memory makes a program transfer easy and a real-time clock is equipped also
■ Equipped with a sampling trace function – Smart solution for program debugging
●The built-in 512 KB flash-ROM can store a 32-kstep
program as well as the comments and FPWIN Pro source
file.
●Program update in a remote location is easy by simply
sending master memory for local installation.
●As the master memory stores the password information,
password protection can be applied for program
transmission. Similarly, upload prohibition/permission
can be setup.
●The built-in real-time clock enables periodical repeated
control and periodical data logging.
The sampling trace function enables the user to monitor a change of I/O condition
or data register value in a very short time interval – an efficiency tool for debugging
a ladder program.
(Available from Ver. 2.0 of the transistor type and relay output types)
To the field
operation
Master memory
Program
transfer
FPWIN GR/Pro
FP-X
Password used ➔ Password locked
Upload prohibited set ➔ Upload prohibited
Program
transfer
FP-X
Upload prohibited not set ➔ Upload permitted
The shortest sampling interval of the normal time-chart monitor is 10ms with the
FPWIN GR or FPWIN Pro, but monitoring in much shorter intervals is often required
during debugging operations. The sampling trace function enables data
accumulation of any 16 contact data and 3 data register values once or several
times within a scan time. Reading out these data through the FPWIN GR or FPWIN
Pro enables the user to confirm an instantaneous change of status by time on the
time-chart monitor.
(Normal Time-Chart Monitor)
■ Programs can be saved without a backup battery, making maintenance easier.
(Sampling Trace)
●The programs and comments are stored in flash-ROM,
requiring no backup batteries.
●A backup battery (AFPX-BATT) is provided for data and
real-time clock.
One battery for C14, two for C30 and three for C60 can be
attached. A two-battery installation can operate for a long
time (10 years or more) without maintenance. (Real-time
clock doesn't work without a battery.)
Battery
holder
Connector
Backup battery
for FP-X
(AFPX-BATT)
Invisible changes become visible!
Protects your important program by preventing illegal copies
■ F-ROM data saving (Data can be saved without a battery.)
●FP-X can store a program, comments, a total of 55 words
of data, and bit setting values in a flash memory without
a battery. All of the data and bits can be stored by
adding optional batteries, but writing into a flash-ROM is
possible without a battery by using applied instructions
(F12, P13). Perfectly suited for data storage of the setup
values and recipes modified several times a day.
* The limitation in a flash-ROM designates the number of rewrites to be 10,000, or the
feasible number to be approx 30,000. However, rewriting every second will generate a
memory failure within a few hours.
R9013
Reading
Flash-ROM
Writing
■ Program upload is easily prohibited by tool software FPWIN.
F12 ICRD K0, K1, DT0
During the first scan, read one block
(2048 words) from the starting address of
DT0 at block number 0.
R0
P13 ICWD DT0, K1, K0
When R0 is turned on, write one block
(2048 words) starting from the address
DT0 at block number 0.
●Reading a program from the PLC main unit is virtually impossible.
●In the upload-prohibited condition, program transfers to the master
memory are also prohibited.
●Release of an upload-prohibited condition is possible with a forced
release accompanied by a program deletion.
●Program updates are easily carried out by transferring the program in
the master memory to FP-X even during an upload-prohibited condition.
The transferred program in FP-X is setup with the same upload
prohibition and permission conditions used in the master memory.
Protected
Protected
Master memory
14
Program download from a PC
Data transfer from the master
Forced input/output
(Original program is required)
Items possible
memory
Ladder monitor
during an upload- Change of data monitor/resistor value (Original program is required)
prohibited condition Contact monitor
Rewrite during RUN mode
Time chart monitor
Items impossible Program upload to a PC
during an upload- Data transfer to the master memory
prohibited condition
(Original program is required)
Password protection
■ More secure eight-character password can be used
along with the previous four-character password.
●The combination of upper and lower case alphanumeric
characters produces 218 trillion combinations. In addition,
after three consecutive entry failures, a power reset is
required for password release.
15
Programming
Programming
Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies.
Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies.
Control FPWIN GR for Windows
Control FPWIN Pro (IEC61131-3 compliant Windows version software)
The ladder programming software for FP series − highly operational software tool for maximizing convenience
in the field.
Compliant with international standard IEC61131-3
Programming software approved by PLC Open
■ Operational Environment
■ Features
1. Easy field operations not requiring the use of a mouse for data
entry, search, writing, monitoring and timer changes, all carried
out only from the keyboard.
2. Allows standard operations in Windows, such as Copy & Paste,
etc.
3. All FP series PLCs are supported. The software assets produced
by using Ver. 4 or Ver. 3 of NPST-GR are usable.
4. Easy programming with wizard functions.
5. Communication with CommX, GTWIN, PCWAY simultaneously
through the same port.
OS
Windows95 (OSR2 or higher)/98/Me/
NT (Ver. 4.0 or later)/2000/XP
Hard disk capacity
At least 40 MB
CPU
Pentium 100 MHz or higher
Onboard memory
At least 64 MB (depends on OS)
Screen resolution
At least 1024 × 768
Display colors
High color (16-bit or higher)
Applicable PLC
FP-X/FP-e/FP0/FPΣ/FP2/FP2SH
Compatible FP-X
version
Relay output type: Ver.2.50 and after
Transistor output type: Ver.2.70 and after
■ Features
By “black boxing” a part of a program, you
can prevent know-how from leaking out
and improve the program’s maintainability.
Programming can be done using the
language most familiar to the developer
or using the language most suited to the
process to be performed. High-level
(structured text) languages that allow
structuring, such as C, are supported.
4. Conversion function for previously
written programs provided to allow
use of program assets.
5. Uploading of source programs
from PLC possible.
2. Easy to reuse well-proven
programs
Maintainability increased by being able to
load programs and comments from the
PLC.
* This only applies to FP-X, FPΣ and FP2
(with comment memory) and to FP2SH
and FP10SH (with card board).
Efficiency when writing programs has
been greatly increased by being able to
split programming up for each function
and process using structured
programming.
Tool bar
Access often-used functions
using icons.
Program status display
3. Keep know-how from getting out
1. Five programming languages can
be used.
6. Programming for all models in the
FP series possible.
Data monitoring window
Search window
Relay monitoring window
Allows you to search various data
Function bar
Program display
Bottons for command input
and confirmation, on-line/offline selection and PLC mode
selection.
Any model can be used.
■ Programming in the most suitable language
●Programming in the language most suited to the process
Easy-to-understand, efficient programs can be created, for example, by
using a ladder program for machine control or ST for communications
control.
■ “Black boxing” of programs
●Multiple passwords for protection of each block
The security level (8 levels) can be input for each block in a program. Only users
of a set security level or higher can make changes.
●Programming in the language you are good at
Function instruction list
I/O comment edit function
Status display
Positioning program
(ST)
Completed
program
Communications
program
(ST)
Classified by type, function
instructions can be selected from
the displayed list.
(Simple help included.)
Displays information concerning
PLC usage situation and settings,
and detailed information when an
error occurs.
■ Accompanying Tools
Text Compiler
Text command input mode
Text command
input mode
●Data Editor
This software for the PC is for reading and writing data
stored in the memory of FP Series main unit or on an IC
card. If a large data table is required in a PLC, the data
can be created and edited on a PC and then dowmload
to the PLC.
●Modem connection
This software is for importing and
exporting programs created in text
format to and from FPWIN GR.
Programs created on the PLC of
another company can be edited as
text and then be transferred to the
FP Series without difficulty.
A ladder diagram is displayed
as a mnemonic code is entered
from the keyboard.
A Wizard function included in FPWIN GR since versions
2.2 can automatically generate ladder programs by
simply entering and selecting required items in the
dedicated screen. It can be used to assist in positioning,
PID instruction input, and FP-e screen display
instruction input.
●Personal preference settings
It is possible to switch among preference settings for
FPWIN GR, Data Editor and Text Compiler that are set
up for different individuals.
16
Block 1
Block 2
Block 1
Block 2
Designer B
(ST)
Person C (operator)
Programming security level
Only block 1
Block 2
Block 1 Low
Block 2
Block 3
Block 4 High
Block 4
Completed
program
Designer C
(ST)
Malfunction handling
program
(ladder)
Designer D
(ladder)
■ Reuse of programs is easy.
● Register time-proven programs by block in the library.
● By using variable identifiers (names), there is no need to be
concerned with addresses for each machine when reusing
programs.
Parts library
Communication via modem is easy with FP Series units
in isolated locations.
●Wizard function
Person B (floor leader)
All blocks
Designer A
(SFC)
Main program
(SFC)
Successive I/O comments can be
input for each device type. Data
from Excel and other applications
can be copied and pasted via the
clipboard.
Person A (designer)
Programming time can be greatly reduced by the easy ability to split and
then integrate programming for each function and process.
New program
Positioning program
Positioning program
■ Operational Environment
OS
Windows95 (OSR2 or higher)/98/Me/NT (Ver. 4.0 or later)/2000/XP
Hard disk capacity
At least 100 MB
CPU
Pentium 100 MHz or higher
Onboard memory
At least 64 MB (depends on OS)
Screen resolution
At least 1024 × 768
Display colors
High Color (16-bit) or higher
Applicable PLC
FP-X/FP-e/FP0/FPΣ/FP1/FP-M/FP2/FP2SH/FP3/FP10SH
Compatible FP-X
version
Relay output type: Ver.5.1 and after
Transistor output type: Ver.5.3 and after
Communications program
Malfunction handling
program
Position
Operation
Function
Modem
Connection
Function
Communications program
Malfunction handling
program
Main program
Initialliton
Setting
Process
17
Programming
Programming
Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies.
Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies.
Control FPWIN GR for Windows
Control FPWIN Pro (IEC61131-3 compliant Windows version software)
The ladder programming software for FP series − highly operational software tool for maximizing convenience
in the field.
Compliant with international standard IEC61131-3
Programming software approved by PLC Open
■ Operational Environment
■ Features
1. Easy field operations not requiring the use of a mouse for data
entry, search, writing, monitoring and timer changes, all carried
out only from the keyboard.
2. Allows standard operations in Windows, such as Copy & Paste,
etc.
3. All FP series PLCs are supported. The software assets produced
by using Ver. 4 or Ver. 3 of NPST-GR are usable.
4. Easy programming with wizard functions.
5. Communication with CommX, GTWIN, PCWAY simultaneously
through the same port.
OS
Windows95 (OSR2 or higher)/98/Me/
NT (Ver. 4.0 or later)/2000/XP
Hard disk capacity
At least 40 MB
CPU
Pentium 100 MHz or higher
Onboard memory
At least 64 MB (depends on OS)
Screen resolution
At least 1024 × 768
Display colors
High color (16-bit or higher)
Applicable PLC
FP-X/FP-e/FP0/FPΣ/FP2/FP2SH
Compatible FP-X
version
Relay output type: Ver.2.50 and after
Transistor output type: Ver.2.70 and after
■ Features
By “black boxing” a part of a program, you
can prevent know-how from leaking out
and improve the program’s maintainability.
Programming can be done using the
language most familiar to the developer
or using the language most suited to the
process to be performed. High-level
(structured text) languages that allow
structuring, such as C, are supported.
4. Conversion function for previously
written programs provided to allow
use of program assets.
5. Uploading of source programs
from PLC possible.
2. Easy to reuse well-proven
programs
Maintainability increased by being able to
load programs and comments from the
PLC.
* This only applies to FP-X, FPΣ and FP2
(with comment memory) and to FP2SH
and FP10SH (with card board).
Efficiency when writing programs has
been greatly increased by being able to
split programming up for each function
and process using structured
programming.
Tool bar
Access often-used functions
using icons.
Program status display
3. Keep know-how from getting out
1. Five programming languages can
be used.
6. Programming for all models in the
FP series possible.
Data monitoring window
Search window
Relay monitoring window
Allows you to search various data
Function bar
Program display
Bottons for command input
and confirmation, on-line/offline selection and PLC mode
selection.
Any model can be used.
■ Programming in the most suitable language
●Programming in the language most suited to the process
Easy-to-understand, efficient programs can be created, for example, by
using a ladder program for machine control or ST for communications
control.
■ “Black boxing” of programs
●Multiple passwords for protection of each block
The security level (8 levels) can be input for each block in a program. Only users
of a set security level or higher can make changes.
●Programming in the language you are good at
Function instruction list
I/O comment edit function
Status display
Positioning program
(ST)
Completed
program
Communications
program
(ST)
Classified by type, function
instructions can be selected from
the displayed list.
(Simple help included.)
Displays information concerning
PLC usage situation and settings,
and detailed information when an
error occurs.
■ Accompanying Tools
Text Compiler
Text command input mode
Text command
input mode
●Data Editor
This software for the PC is for reading and writing data
stored in the memory of FP Series main unit or on an IC
card. If a large data table is required in a PLC, the data
can be created and edited on a PC and then dowmload
to the PLC.
●Modem connection
This software is for importing and
exporting programs created in text
format to and from FPWIN GR.
Programs created on the PLC of
another company can be edited as
text and then be transferred to the
FP Series without difficulty.
A ladder diagram is displayed
as a mnemonic code is entered
from the keyboard.
A Wizard function included in FPWIN GR since versions
2.2 can automatically generate ladder programs by
simply entering and selecting required items in the
dedicated screen. It can be used to assist in positioning,
PID instruction input, and FP-e screen display
instruction input.
●Personal preference settings
It is possible to switch among preference settings for
FPWIN GR, Data Editor and Text Compiler that are set
up for different individuals.
16
Block 1
Block 2
Block 1
Block 2
Designer B
(ST)
Person C (operator)
Programming security level
Only block 1
Block 2
Block 1 Low
Block 2
Block 3
Block 4 High
Block 4
Completed
program
Designer C
(ST)
Malfunction handling
program
(ladder)
Designer D
(ladder)
■ Reuse of programs is easy.
● Register time-proven programs by block in the library.
● By using variable identifiers (names), there is no need to be
concerned with addresses for each machine when reusing
programs.
Parts library
Communication via modem is easy with FP Series units
in isolated locations.
●Wizard function
Person B (floor leader)
All blocks
Designer A
(SFC)
Main program
(SFC)
Successive I/O comments can be
input for each device type. Data
from Excel and other applications
can be copied and pasted via the
clipboard.
Person A (designer)
Programming time can be greatly reduced by the easy ability to split and
then integrate programming for each function and process.
New program
Positioning program
Positioning program
■ Operational Environment
OS
Windows95 (OSR2 or higher)/98/Me/NT (Ver. 4.0 or later)/2000/XP
Hard disk capacity
At least 100 MB
CPU
Pentium 100 MHz or higher
Onboard memory
At least 64 MB (depends on OS)
Screen resolution
At least 1024 × 768
Display colors
High Color (16-bit) or higher
Applicable PLC
FP-X/FP-e/FP0/FPΣ/FP1/FP-M/FP2/FP2SH/FP3/FP10SH
Compatible FP-X
version
Relay output type: Ver.5.1 and after
Transistor output type: Ver.5.3 and after
Communications program
Malfunction handling
program
Position
Operation
Function
Modem
Connection
Function
Communications program
Malfunction handling
program
Main program
Initialliton
Setting
Process
17
Part Number List
Part Number List
N/A: Not available
A: Available
FP-X Control Unit
FP-X Add-on Cassette
Product name
Product name
FP-X C14R
Power supply
100 to 240V AC
Relay output
Transistor output
8-point input of 24 V DC, bi-directional (sink/source)
AFPX-IN8
8-point output of NPN transistor, 0.3 A/24 V DC
AFPX-TR8
6-point output of PNP transistor, 0.5 A/24 V DC
AFPX-TR6P
FP-X Pulse I/O cassette
High-speed counter input: single-phase 2 ch., each 80 kHz or two-phase 1 ch., 30 kHz, Pulse output: one axis 100 kHz/ch.
(Use restriction is applied for a two-unit installation)
Cannot be used with a transistor output type control unit.
AFPX-PLS
FP-X Output cassette
32k steps
2-point
A
AFPX-C30RD
24V DC
16-point input of 24 V DC, 14-point output of 2 A relay
32k steps
2-point
A
AFPX-C30R
100 to 240V AC
32-point input of 24 V DC, 28-point output of 2 A relay
32k steps
4-point
A
AFPX-C60R
FP-X Analog input cassette
2-point analog input, 0 to 10 V/0 to 20 mA, 12-bit, 2 ms/2 ch. (non-insulated)
AFPX-AD2
24V DC
32-point input of 24 V DC, 28-point output of 2 A relay
32k steps
4-point
A
AFPX-C60RD
FP-X Analog output cassette
2-point analog output, 0 to 10 V/0 to 20 mA, 12-bit, 2 ms/2 ch. (insulated)
AFPX-DA2
FP-X Analog I/O cassette
2-point analog input, 0 to 5 V/0 to 10 V or 0 to 20 m, 12-bit, 2 ms/2 ch., 1 point analog output, 0 to 10 V or 0 to 20 m, 12-bit, 1 ms/1 ch. (insulated)
AFPX-A21
FP-X Thermocouple input cassette
2-point thermocouple input, K/J type, Resolution: 0.2°C, 200 ms/2 ch. Channels insulated
AFPX-TC2
100 to 240V AC
8-point input of 24 V DC, 0.5 A/5 to 24 V DC, 6-point output of transistor (NPN)
16k steps
2-point
N/A
AFPX-C14T
24V DC
8-point input of 24 V DC, 0.5 A/5 to 24 V DC, 6-point output of transistor (NPN)
16k steps
2-point
N/A
AFPX-C14TD
100 to 240V AC
8-point input of 24 V DC, 0.5 A/24 V DC, 6-point output of transistor (PNP)
16k steps
2-point
N/A
AFPX-C14P
FP-X Master memory cassette
with a real-time clock
Master memory: Capable of storing all program steps and comments simultaneously. Storage of FPWIN Pro source files
Real-time clock: Year, month, day, hour, minute, second, day of week (optional battery required)
AFPX-MRTC
24V DC
8-point input of 24 V DC, 0.5 A/24 V DC, 6-point output of transistor (PNP)
16k steps
2-point
N/A
AFPX-C14PD
FP-X COM1 Communication cassette
RS232C 1 ch. RS and CS control signal equipped (non-insulated)
AFPX-COM1
16-point input of 24 V DC, 0.5 A/5 to 24 V DC, 14-point output of transistor (NPN)
32k steps
2-point
A
AFPX-C30T
FP-X COM2 Communication cassette
RS232C 2 ch. (non-insulated)
AFPX-COM2
FP-X COM3 Communication cassette
RS485/RS422 selectable 1ch (insulated)
AFPX-COM3
FP-X COM4 Communication cassette
RS485 1 ch. (insulated) + RS232C 1 ch. (non-insulated)
AFPX-COM4
FP-X COM5 Communication cassette
Ethernet 1 ch. (10BASE-T, 100BASE-TX) + RS232C 1 ch. (non-insulated)
AFPX-COM5
FP-X COM6 Communication cassette
RS485 2 ch. (insulated)
AFPX-COM6
100 to 240V AC
24V DC
100 to 240V AC
16-point input of 24 V DC, 0.5 A/5 to 24 V DC, 14-point output of transistor (NPN)
32k steps
2-point
A
AFPX-C30TD
16-point input of 24 V DC, 0.5 A/24 V DC, 14-point output of transistor (PNP)
32k steps
2-point
A
AFPX-C30P
16-point input of 24 V DC, 0.5 A/24 V DC, 14-point output of transistor (PNP)
32k steps
2-point
A
AFPX-C30PD
100 to 240V AC
32-point input of 24 V DC, 0.5 A/5 to 24 V DC, 28-point output of transistor (NPN)
32k steps
4-point
A
AFPX-C60T
24V DC
32-point input of 24 V DC, 0.5 A/5 to 24 V DC, 28-point output of transistor (NPN)
32k steps
4-point
A
AFPX-C60TD
100 to 240V AC
32-point input of 24 V DC, 0.5 A/24 V DC, 28-point output of transistor (PNP)
32k steps
4-point
A
AFPX-C60P
24V DC
32-point input of 24 V DC, 0.5 A/24 V DC, 28-point output of transistor (PNP)
32k steps
4-point
A
AFPX-C60PD
24V DC
FP-X C60TD
FP-X C60P
FP-X Input cassette
AFPX-C14R
16-point input of 24 V DC, 14-point output of 2 A relay
FP-X C30PD
FP-X C60T
AFPX-IN4T3
100 to 240V AC
FP-X C30TD
FP-X C30P
N/A
FP-X C60PD
FP-X Options and Service Parts
Product name
FP-X Backup battery
Note: The 24 V DC inputs of all units are bi-directional (sink/source) inputs.
FP-X Expansion cable
FP-X Expansion Unit
Product name
Power supply
Specifications
8-point input of 24 V DC, 8-point relay output of 2 A
Relay output
FP-X E16R Expansion I/O unit
FP-X E30R Expansion I/O unit
FP-X E30RD Expansion I/O unit
FP-X E16T Expansion I/O unit
(Power is supplied from the left-side unit.) Remarks; Two or more E16R can't be connected serially because it can't supply the power to other units. With an 8cm extension cable
100 to 240V AC
24V DC
Transistor output
FP-X E30T Expansion I/O unit
FP-X E30PD Expansion I/O unit
FP-X E30P Expansion I/O unit
Remarks; Possible to connect up to 8 units including E16R, EFP0. With an 8cm extension cable
16-point input of 24 V DC, 14-point relay output of 2 A
Remarks; Possible to connect up to 8 units including E16R, EFP0. With an 8cm extension cable
8-point input of 24 V DC, 8-point transistor (NPN) output of 0.5 A
8-point input of 24 V DC, 8-point transistor (PNP) output of 0.5 A
(Power is supplied from the left-side unit.)
FP-X E30TD Expansion I/O unit
16-point input of 24 V DC, 14-point relay output of 2 A
(Power is supplied from the left-side unit.) Remarks; Two or more E16T cannot be connected serially because it cannot supply the power to other units. With an 8cm extension cable
FP-X E16P Expansion I/O unit
Expansion FP0 Adapter
Part number
4-point input of 24 V DC, bi-directional (sink/source), 3-point output of NPN transistor 0.3 A/24 V DC
AFPX-C14RD
FP-X C14PD
FP-X C30T
2-point
Specifications
FP-X Input /Output cassette
N/A
FP-X C14TD
FP-X C14P
16k steps
Part number
2-point
FP-X C60RD
FP-X C14T
Potentiometer
USB
port
16k steps
24V DC
FP-X C30RD
FP-X C60R
8-point input of 24 V DC, 6-point output of 2 A relay
Program
capacity
8-point input of 24 V DC, 6-point output of 2 A relay
FP-X C14RD
FP-X C30R
Specifications
24V DC
Remarks; Two or more E16T cannot be connected serially because it cannot supply the power to other units. With an 8cm extension cable
16-point input of 24 V DC, 14-point transistor (NPN) output of 0.5 A
Part number
FP-X Terminal block
Specifications
Part number
Battery for backing up the operation memory and real-time clock
AFPX-BATT
Expansion unit connection cable, 8 cm
AFPX-EC08
Expansion unit connection cable, 30 cm
AFPX-EC30
Expansion unit connection cable, 80 cm
AFPX-EC80
Terminal block for C30, C60 and E30, 21 pins, cover with no marking, four units included
AFPX-TAN1
AFPX-E16R
AFPX-E30R
AFPX-E30RD
AFPX-E16T
AFPX-E16P
AFPX-E30TD
Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
100 to 240V AC
16-point input of 24 V DC, 14-point transistor (NPN) output of 0.5 A
AFPX-E30T
Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
24V DC
16-point input of 24 V DC, 14-point transistor (PNP) output of 0.5 A
AFPX-E30PD
Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
100 to 240V AC
16-point input of 24 V DC, 14-point transistor (PNP) output of 0.5 A
AFPX-E30P
Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
24V DC
Up to 3 FP0 expansion units can be connected via an adapter.
With an 8cm extension cable and power cable
AFPX-EFP0
Note: The 24 V DC inputs of all units are bi-directional (sink/source) inputs.
18
19
Part Number List
Part Number List
N/A: Not available
A: Available
FP-X Control Unit
FP-X Add-on Cassette
Product name
Product name
FP-X C14R
Power supply
100 to 240V AC
Relay output
Transistor output
8-point input of 24 V DC, bi-directional (sink/source)
AFPX-IN8
8-point output of NPN transistor, 0.3 A/24 V DC
AFPX-TR8
6-point output of PNP transistor, 0.5 A/24 V DC
AFPX-TR6P
FP-X Pulse I/O cassette
High-speed counter input: single-phase 2 ch., each 80 kHz or two-phase 1 ch., 30 kHz, Pulse output: one axis 100 kHz/ch.
(Use restriction is applied for a two-unit installation)
Cannot be used with a transistor output type control unit.
AFPX-PLS
FP-X Output cassette
32k steps
2-point
A
AFPX-C30RD
24V DC
16-point input of 24 V DC, 14-point output of 2 A relay
32k steps
2-point
A
AFPX-C30R
100 to 240V AC
32-point input of 24 V DC, 28-point output of 2 A relay
32k steps
4-point
A
AFPX-C60R
FP-X Analog input cassette
2-point analog input, 0 to 10 V/0 to 20 mA, 12-bit, 2 ms/2 ch. (non-insulated)
AFPX-AD2
24V DC
32-point input of 24 V DC, 28-point output of 2 A relay
32k steps
4-point
A
AFPX-C60RD
FP-X Analog output cassette
2-point analog output, 0 to 10 V/0 to 20 mA, 12-bit, 2 ms/2 ch. (insulated)
AFPX-DA2
FP-X Analog I/O cassette
2-point analog input, 0 to 5 V/0 to 10 V or 0 to 20 m, 12-bit, 2 ms/2 ch., 1 point analog output, 0 to 10 V or 0 to 20 m, 12-bit, 1 ms/1 ch. (insulated)
AFPX-A21
FP-X Thermocouple input cassette
2-point thermocouple input, K/J type, Resolution: 0.2°C, 200 ms/2 ch. Channels insulated
AFPX-TC2
100 to 240V AC
8-point input of 24 V DC, 0.5 A/5 to 24 V DC, 6-point output of transistor (NPN)
16k steps
2-point
N/A
AFPX-C14T
24V DC
8-point input of 24 V DC, 0.5 A/5 to 24 V DC, 6-point output of transistor (NPN)
16k steps
2-point
N/A
AFPX-C14TD
100 to 240V AC
8-point input of 24 V DC, 0.5 A/24 V DC, 6-point output of transistor (PNP)
16k steps
2-point
N/A
AFPX-C14P
FP-X Master memory cassette
with a real-time clock
Master memory: Capable of storing all program steps and comments simultaneously. Storage of FPWIN Pro source files
Real-time clock: Year, month, day, hour, minute, second, day of week (optional battery required)
AFPX-MRTC
24V DC
8-point input of 24 V DC, 0.5 A/24 V DC, 6-point output of transistor (PNP)
16k steps
2-point
N/A
AFPX-C14PD
FP-X COM1 Communication cassette
RS232C 1 ch. RS and CS control signal equipped (non-insulated)
AFPX-COM1
16-point input of 24 V DC, 0.5 A/5 to 24 V DC, 14-point output of transistor (NPN)
32k steps
2-point
A
AFPX-C30T
FP-X COM2 Communication cassette
RS232C 2 ch. (non-insulated)
AFPX-COM2
FP-X COM3 Communication cassette
RS485/RS422 selectable 1ch (insulated)
AFPX-COM3
FP-X COM4 Communication cassette
RS485 1 ch. (insulated) + RS232C 1 ch. (non-insulated)
AFPX-COM4
FP-X COM5 Communication cassette
Ethernet 1 ch. (10BASE-T, 100BASE-TX) + RS232C 1 ch. (non-insulated)
AFPX-COM5
FP-X COM6 Communication cassette
RS485 2 ch. (insulated)
AFPX-COM6
100 to 240V AC
24V DC
100 to 240V AC
16-point input of 24 V DC, 0.5 A/5 to 24 V DC, 14-point output of transistor (NPN)
32k steps
2-point
A
AFPX-C30TD
16-point input of 24 V DC, 0.5 A/24 V DC, 14-point output of transistor (PNP)
32k steps
2-point
A
AFPX-C30P
16-point input of 24 V DC, 0.5 A/24 V DC, 14-point output of transistor (PNP)
32k steps
2-point
A
AFPX-C30PD
100 to 240V AC
32-point input of 24 V DC, 0.5 A/5 to 24 V DC, 28-point output of transistor (NPN)
32k steps
4-point
A
AFPX-C60T
24V DC
32-point input of 24 V DC, 0.5 A/5 to 24 V DC, 28-point output of transistor (NPN)
32k steps
4-point
A
AFPX-C60TD
100 to 240V AC
32-point input of 24 V DC, 0.5 A/24 V DC, 28-point output of transistor (PNP)
32k steps
4-point
A
AFPX-C60P
24V DC
32-point input of 24 V DC, 0.5 A/24 V DC, 28-point output of transistor (PNP)
32k steps
4-point
A
AFPX-C60PD
24V DC
FP-X C60TD
FP-X C60P
FP-X Input cassette
AFPX-C14R
16-point input of 24 V DC, 14-point output of 2 A relay
FP-X C30PD
FP-X C60T
AFPX-IN4T3
100 to 240V AC
FP-X C30TD
FP-X C30P
N/A
FP-X C60PD
FP-X Options and Service Parts
Product name
FP-X Backup battery
Note: The 24 V DC inputs of all units are bi-directional (sink/source) inputs.
FP-X Expansion cable
FP-X Expansion Unit
Product name
Power supply
Specifications
8-point input of 24 V DC, 8-point relay output of 2 A
Relay output
FP-X E16R Expansion I/O unit
FP-X E30R Expansion I/O unit
FP-X E30RD Expansion I/O unit
FP-X E16T Expansion I/O unit
(Power is supplied from the left-side unit.) Remarks; Two or more E16R can't be connected serially because it can't supply the power to other units. With an 8cm extension cable
100 to 240V AC
24V DC
Transistor output
FP-X E30T Expansion I/O unit
FP-X E30PD Expansion I/O unit
FP-X E30P Expansion I/O unit
Remarks; Possible to connect up to 8 units including E16R, EFP0. With an 8cm extension cable
16-point input of 24 V DC, 14-point relay output of 2 A
Remarks; Possible to connect up to 8 units including E16R, EFP0. With an 8cm extension cable
8-point input of 24 V DC, 8-point transistor (NPN) output of 0.5 A
8-point input of 24 V DC, 8-point transistor (PNP) output of 0.5 A
(Power is supplied from the left-side unit.)
FP-X E30TD Expansion I/O unit
16-point input of 24 V DC, 14-point relay output of 2 A
(Power is supplied from the left-side unit.) Remarks; Two or more E16T cannot be connected serially because it cannot supply the power to other units. With an 8cm extension cable
FP-X E16P Expansion I/O unit
Expansion FP0 Adapter
Part number
4-point input of 24 V DC, bi-directional (sink/source), 3-point output of NPN transistor 0.3 A/24 V DC
AFPX-C14RD
FP-X C14PD
FP-X C30T
2-point
Specifications
FP-X Input /Output cassette
N/A
FP-X C14TD
FP-X C14P
16k steps
Part number
2-point
FP-X C60RD
FP-X C14T
Potentiometer
USB
port
16k steps
24V DC
FP-X C30RD
FP-X C60R
8-point input of 24 V DC, 6-point output of 2 A relay
Program
capacity
8-point input of 24 V DC, 6-point output of 2 A relay
FP-X C14RD
FP-X C30R
Specifications
24V DC
Remarks; Two or more E16T cannot be connected serially because it cannot supply the power to other units. With an 8cm extension cable
16-point input of 24 V DC, 14-point transistor (NPN) output of 0.5 A
Part number
FP-X Terminal block
Specifications
Part number
Battery for backing up the operation memory and real-time clock
AFPX-BATT
Expansion unit connection cable, 8 cm
AFPX-EC08
Expansion unit connection cable, 30 cm
AFPX-EC30
Expansion unit connection cable, 80 cm
AFPX-EC80
Terminal block for C30, C60 and E30, 21 pins, cover with no marking, four units included
AFPX-TAN1
AFPX-E16R
AFPX-E30R
AFPX-E30RD
AFPX-E16T
AFPX-E16P
AFPX-E30TD
Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
100 to 240V AC
16-point input of 24 V DC, 14-point transistor (NPN) output of 0.5 A
AFPX-E30T
Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
24V DC
16-point input of 24 V DC, 14-point transistor (PNP) output of 0.5 A
AFPX-E30PD
Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
100 to 240V AC
16-point input of 24 V DC, 14-point transistor (PNP) output of 0.5 A
AFPX-E30P
Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
24V DC
Up to 3 FP0 expansion units can be connected via an adapter.
With an 8cm extension cable and power cable
AFPX-EFP0
Note: The 24 V DC inputs of all units are bi-directional (sink/source) inputs.
18
19
Related Products
Related Products
Related Products List
Related Products List
FP0 Expansion Units
Product name
Number of I/O points
8
Part number
FP0-E8X
FP0-E8RS
FP0-E8RM
FP0-E8YRS
AFP03003
AFP03023
AFP03013
AFP03020
MIL connector
FP0-E8YT
AFP03040
MIL connector
Terminal block
Molex connecter
FP0-E16X
AFP03303
Input
Output
Connection type
24 V DC Sink/Source (±common)
−
24 V DC
24 V DC Sink/Source (±common)
Relay output: 2 A
MIL connector
Terminal block
Molex connecter
Terminal block
8
8
Output: 8
24 V DC
−
8
Output: 8
−
−
16
Input: 16
−
24 V DC Sink/Source (±common)
Relay output: 2 A
Transistor output:
NPN 0.1 A/5 to 24 V
−
24 V DC
24 V DC Sink/Source (±common)
Relay output: 2 A
24 V DC Sink/Source (±common)
Transistor output:
NPN 0.1 A/5 to 24 V
MIL connector
FP0-E16T
AFP03343
−
Transistor output:
NPN 0.1 A/5 to 24 V
Transistor output:
NPN 0.1 A/5 to 24 V
MIL connector
FP0-E16YT
AFP03340
MIL connector
FP0-E32T
AFP03543
16
FP0 E32 Expansion Unit
Product name
Product number
Power supply
voltage
−
Input: 8
Input: 4
Output: 4
FP0 E8 Expansion Unit
FP0 E16 Expansion Unit
Programmable Display GT Series
Specifications
16
Input: 8
Output: 8
Input: 8
Output: 8
−
16
Output: 16
−
32
Input: 16
Output: 16
−
24 V DC Sink/Source (±common)
RS422/RS485 type
STN monochrome LCD
RS232C type
FP0-E16RS
FP0-E16RM
24V DC
RS422/RS485 type
AFP03323
AFP03313
GT01R Main Unit
RS422/RS485 type
STN monochrome LCD
RS232C type
24V DC
RS422/RS485 type
GT11 Main Unit
Specifications
K, J, T, R thermocouple, Resolution: 0.1 °C
K, J, T, R thermocouple, Resolution: 0.1 °C
Number of channels:
Input range:
FP0 Analog I/O unit
FP0 D/A Converter Unit
STN monochrome LCD
FP0 I/O Link unit
Number of channels:
Output range:
Number of channels:
Input range:
Number of channels:
Output range:
Product number
FP0-TC4
FP0-TC8
2 channels
0 to 5 V, –10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
1 channel
–10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
8 channels
0 to 5, –10 to +10 V, –100 to 100 mV (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
4 channels
–10 to +10 V (Resolution: 1/4000)
4 to 20 mA (Resolution: 1/4000)
Part number
AFP0420
AFP0421
Note: Accuracy will change if an FP0 thermocouple unit is used at the same time. For details, please refer to the FP0 catalog
or to the CC-Link Unit manual.
This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system).
FP0-A21
Part number
FP-X
English: Full type
English: Small type
English: Ver. up type
Chinese
Chinese: Ver. up type
Korean
AFPS10520
CD-ROM for Windows
FPWIN GR
for Windows
AFPS11520
CD-ROM for Windows
AFPS10520R
CD-ROM for Windows
AFPS10820
CD-ROM for Windows
AFPS10820R
CD-ROM for Windows
AFPS10920
CD-ROM for Windows
*The production of FP1, FP-M, FP3/FP10SH has been discontinued.
Note) FP-X compatible versions: Relay output type - Ver. 2.50 or later; Transistor output type - Ver. 2.70 or later
A
A
FPΣ
A
A
FP0
.
FP-e
A
A
Product name
Type
English: Full type
English: Small type
Part number
CD-ROM for Windows
CD-ROM for Windows
AFPS50550
AFPS51550
*The production of FP1, FP-M, FP3/FP10SH has been discontinued.
Note) FP-X compatible versions: Relay output type - Ver. 5.1 or later; Transistor output type - Ver. 5.3 or later
20
RS232C type
TFT monochrome LCD
24V DC
RS422/RS485 type
GT32T0 Main Unit
FP0-A80
AFP0401
FP0-A04V
AFP04121
FP0-A04I
AFP04123
RS232C type
TFT color LCD
AFP07943
24 V DC
FP0-IOL
AFP0732
A
A
A
N/A
FP2SH FP-M*
A
N/A
TFT color LCD
24V DC
Part number
FP0-CCLS
A
A
RS232C type
RS422/RS485 type
24 V DC
Applicable PLC
FP0
FP1*
FP2
10k
24V DC
RS422/RS485 type
A
A
Control CommX Ver. 1.3 (OCX for Communication)
Product name
FP3*
.
FP10SH
A
N/A
Part number
Product name
AFW20011
FP Web-Server unit
Control CommX USB port
AFW20031
FP Web Configurator Tool
Product name
AIGT0030B1
Ash gray
AIGT0030H1
Black
AIGT0032B1
Ash gray
AIGT0032H1
Black
AIGT0030B
Ash gray
AIGT0030H
Black
AIGT0032B
Ash gray
AIGT0032H
Pure black
AIGT0230B1
Silver
AIGT0230H1
Pure black
AIGT0232B1
Silver
AIGT0232H1
Pure black
AIGT0230B
Silver
AIGT0230H
Pure black
AIGT0232B
Silver
AIGT0232H
Black
AIGT2030B
Ash gray
AIGT2030H
Black
AIGT2032B
Ash gray
AIGT2032H
Black
AIGT2230B
Silver
AIGT2230H
Black
AIGT2232B
Silver
AIGT2232H
Pure black
AIG32MQ02D
Silver
AIG32MQ03D
Pure black
AIG32MQ04D
Silver
AIG32MQ05D
Pure black
AIG32TQ02D
Silver
AIG32TQ03D
Pure black
AIG32TQ04D
Silver
AIG32TQ05D
Pure black
AIG32TQ12D
Silver
AIG32TQ13D
Pure black
AIG32TQ14D
Silver
AIG32TQ15D
FP Web-Server Unit
Control CommX IBM printer port
FP Memory Loader
Black
Part number
AFP0610
AFPS30510
PCWAY Ver. 2.7 (Operation Data Managing Software)
Part number
Product name
Data non-hold type
AFP8670
PCWAY USB port version
Data hold type
AFP8671
PCWAY Version upgrade
Part number
AFW10031
AFW10401
* Charged version upgrade for Ver. 2.0 to 2.6.
A
A
A
A
A
A
A
A
A
A: Available, N/A: Not available
Key Unit
Economical type is available for secondary key.
The key unit is available for PCWAY and Control CommX.
Product name
Control FPWIN Pro (IEC61131-3 compliant Windows version software)
FPWIN Pro
for Windows
RS422/RS485 type
AFP0480
Control FPWIN GR for Windows
Type
24V DC
GT32M Main Unit
Power supply
Product number
voltage
Specifications
This unit is for making the FP0 function as a slave station of the CC-Link.
Only one unit can be connected to the furthest right edge of the FP0 expansion bus.
RS232C type
STN color LCD
GT32T1 Main Unit
(Ethernet and sound
output function supported)
Product name
24V DC
RS422/RS485 type
FP0 Link Units
FP0 CC-Link Slave unit
RS232C type
GT21C Main Unit
Product name
Product name
RS232C type
5V DC
FP0 Intelligent Units
FP0 A/D Converter Unit
RS232C type
5V DC
Notes: 1) The relay output type expansion units come with a power cable (part number AFP0581). (The transistor output type needs no power cable.)
2) The terminal block type relay output units have 2 terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm wide screwdriver.
Preferably use the specific terminal block screwdriver (part number AFP0806, Phoenix type code SZS 0. 4 × 2.5 mm) or equivalent.
3) The connector-type relay output units have 2 connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins).
Use the specific Molex connector press-fit tool (part number AFP0805, Nihon Molex type code 57189-5000) or equivalent.
4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number AXY52000) for wire-pressed terminal cable.
5) A PNP 0.1 A/24 V DC transistor output type is also available. When ordering it, please replace "T" in the end of product number for the NPN type with "P".
FP0 Thermocouple unit
Part number
Description
GT01 Main Unit
Key unit USB port version
FP-X
FPΣ
FP0
.
FP-e
A
A
A
A
A
A
Applicable PLC
FP0
FP1*
FP2
10k
A
A
A
A
A
N/A
FP2SH FP-M*
A
N/A
A
A
Part number
AFW1033
FP3*
.
FP10SH
A
N/A
A: Available, N/A: Not available
21
Related Products
Related Products
Related Products List
Related Products List
FP0 Expansion Units
Product name
Number of I/O points
8
Part number
FP0-E8X
FP0-E8RS
FP0-E8RM
FP0-E8YRS
AFP03003
AFP03023
AFP03013
AFP03020
MIL connector
FP0-E8YT
AFP03040
MIL connector
Terminal block
Molex connecter
FP0-E16X
AFP03303
Input
Output
Connection type
24 V DC Sink/Source (±common)
−
24 V DC
24 V DC Sink/Source (±common)
Relay output: 2 A
MIL connector
Terminal block
Molex connecter
Terminal block
8
8
Output: 8
24 V DC
−
8
Output: 8
−
−
16
Input: 16
−
24 V DC Sink/Source (±common)
Relay output: 2 A
Transistor output:
NPN 0.1 A/5 to 24 V
−
24 V DC
24 V DC Sink/Source (±common)
Relay output: 2 A
24 V DC Sink/Source (±common)
Transistor output:
NPN 0.1 A/5 to 24 V
MIL connector
FP0-E16T
AFP03343
−
Transistor output:
NPN 0.1 A/5 to 24 V
Transistor output:
NPN 0.1 A/5 to 24 V
MIL connector
FP0-E16YT
AFP03340
MIL connector
FP0-E32T
AFP03543
16
FP0 E32 Expansion Unit
Product name
Product number
Power supply
voltage
−
Input: 8
Input: 4
Output: 4
FP0 E8 Expansion Unit
FP0 E16 Expansion Unit
Programmable Display GT Series
Specifications
16
Input: 8
Output: 8
Input: 8
Output: 8
−
16
Output: 16
−
32
Input: 16
Output: 16
−
24 V DC Sink/Source (±common)
RS422/RS485 type
STN monochrome LCD
RS232C type
FP0-E16RS
FP0-E16RM
24V DC
RS422/RS485 type
AFP03323
AFP03313
GT01R Main Unit
RS422/RS485 type
STN monochrome LCD
RS232C type
24V DC
RS422/RS485 type
GT11 Main Unit
Specifications
K, J, T, R thermocouple, Resolution: 0.1 °C
K, J, T, R thermocouple, Resolution: 0.1 °C
Number of channels:
Input range:
FP0 Analog I/O unit
FP0 D/A Converter Unit
STN monochrome LCD
FP0 I/O Link unit
Number of channels:
Output range:
Number of channels:
Input range:
Number of channels:
Output range:
Product number
FP0-TC4
FP0-TC8
2 channels
0 to 5 V, –10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
1 channel
–10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
8 channels
0 to 5, –10 to +10 V, –100 to 100 mV (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
4 channels
–10 to +10 V (Resolution: 1/4000)
4 to 20 mA (Resolution: 1/4000)
Part number
AFP0420
AFP0421
Note: Accuracy will change if an FP0 thermocouple unit is used at the same time. For details, please refer to the FP0 catalog
or to the CC-Link Unit manual.
This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system).
FP0-A21
Part number
FP-X
English: Full type
English: Small type
English: Ver. up type
Chinese
Chinese: Ver. up type
Korean
AFPS10520
CD-ROM for Windows
FPWIN GR
for Windows
AFPS11520
CD-ROM for Windows
AFPS10520R
CD-ROM for Windows
AFPS10820
CD-ROM for Windows
AFPS10820R
CD-ROM for Windows
AFPS10920
CD-ROM for Windows
*The production of FP1, FP-M, FP3/FP10SH has been discontinued.
Note) FP-X compatible versions: Relay output type - Ver. 2.50 or later; Transistor output type - Ver. 2.70 or later
A
A
FPΣ
A
A
FP0
.
FP-e
A
A
Product name
Type
English: Full type
English: Small type
Part number
CD-ROM for Windows
CD-ROM for Windows
AFPS50550
AFPS51550
*The production of FP1, FP-M, FP3/FP10SH has been discontinued.
Note) FP-X compatible versions: Relay output type - Ver. 5.1 or later; Transistor output type - Ver. 5.3 or later
20
RS232C type
TFT monochrome LCD
24V DC
RS422/RS485 type
GT32T0 Main Unit
FP0-A80
AFP0401
FP0-A04V
AFP04121
FP0-A04I
AFP04123
RS232C type
TFT color LCD
AFP07943
24 V DC
FP0-IOL
AFP0732
A
A
A
N/A
FP2SH FP-M*
A
N/A
TFT color LCD
24V DC
Part number
FP0-CCLS
A
A
RS232C type
RS422/RS485 type
24 V DC
Applicable PLC
FP0
FP1*
FP2
10k
24V DC
RS422/RS485 type
A
A
Control CommX Ver. 1.3 (OCX for Communication)
Product name
FP3*
.
FP10SH
A
N/A
Part number
Product name
AFW20011
FP Web-Server unit
Control CommX USB port
AFW20031
FP Web Configurator Tool
Product name
AIGT0030B1
Ash gray
AIGT0030H1
Black
AIGT0032B1
Ash gray
AIGT0032H1
Black
AIGT0030B
Ash gray
AIGT0030H
Black
AIGT0032B
Ash gray
AIGT0032H
Pure black
AIGT0230B1
Silver
AIGT0230H1
Pure black
AIGT0232B1
Silver
AIGT0232H1
Pure black
AIGT0230B
Silver
AIGT0230H
Pure black
AIGT0232B
Silver
AIGT0232H
Black
AIGT2030B
Ash gray
AIGT2030H
Black
AIGT2032B
Ash gray
AIGT2032H
Black
AIGT2230B
Silver
AIGT2230H
Black
AIGT2232B
Silver
AIGT2232H
Pure black
AIG32MQ02D
Silver
AIG32MQ03D
Pure black
AIG32MQ04D
Silver
AIG32MQ05D
Pure black
AIG32TQ02D
Silver
AIG32TQ03D
Pure black
AIG32TQ04D
Silver
AIG32TQ05D
Pure black
AIG32TQ12D
Silver
AIG32TQ13D
Pure black
AIG32TQ14D
Silver
AIG32TQ15D
FP Web-Server Unit
Control CommX IBM printer port
FP Memory Loader
Black
Part number
AFP0610
AFPS30510
PCWAY Ver. 2.7 (Operation Data Managing Software)
Part number
Product name
Data non-hold type
AFP8670
PCWAY USB port version
Data hold type
AFP8671
PCWAY Version upgrade
Part number
AFW10031
AFW10401
* Charged version upgrade for Ver. 2.0 to 2.6.
A
A
A
A
A
A
A
A
A
A: Available, N/A: Not available
Key Unit
Economical type is available for secondary key.
The key unit is available for PCWAY and Control CommX.
Product name
Control FPWIN Pro (IEC61131-3 compliant Windows version software)
FPWIN Pro
for Windows
RS422/RS485 type
AFP0480
Control FPWIN GR for Windows
Type
24V DC
GT32M Main Unit
Power supply
Product number
voltage
Specifications
This unit is for making the FP0 function as a slave station of the CC-Link.
Only one unit can be connected to the furthest right edge of the FP0 expansion bus.
RS232C type
STN color LCD
GT32T1 Main Unit
(Ethernet and sound
output function supported)
Product name
24V DC
RS422/RS485 type
FP0 Link Units
FP0 CC-Link Slave unit
RS232C type
GT21C Main Unit
Product name
Product name
RS232C type
5V DC
FP0 Intelligent Units
FP0 A/D Converter Unit
RS232C type
5V DC
Notes: 1) The relay output type expansion units come with a power cable (part number AFP0581). (The transistor output type needs no power cable.)
2) The terminal block type relay output units have 2 terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm wide screwdriver.
Preferably use the specific terminal block screwdriver (part number AFP0806, Phoenix type code SZS 0. 4 × 2.5 mm) or equivalent.
3) The connector-type relay output units have 2 connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins).
Use the specific Molex connector press-fit tool (part number AFP0805, Nihon Molex type code 57189-5000) or equivalent.
4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number AXY52000) for wire-pressed terminal cable.
5) A PNP 0.1 A/24 V DC transistor output type is also available. When ordering it, please replace "T" in the end of product number for the NPN type with "P".
FP0 Thermocouple unit
Part number
Description
GT01 Main Unit
Key unit USB port version
FP-X
FPΣ
FP0
.
FP-e
A
A
A
A
A
A
Applicable PLC
FP0
FP1*
FP2
10k
A
A
A
A
A
N/A
FP2SH FP-M*
A
N/A
A
A
Part number
AFW1033
FP3*
.
FP10SH
A
N/A
A: Available, N/A: Not available
21
Specifications
Specifications
3. Controls Specifications
1. General Specifications
Item
Rated voltage
Description
Item
Rush current
Relay symbol method
Control method
Cyclic operation method
Insulation method
C14: 24V DC/0.15A, C30 and C60: 24V DC/0.4A
Program memory
Flash ROM built-in (no battery backup required)
Rated input voltage
40 A or less (C14), 45 A or less (C30, C60) at 25°C (AC power)
Program capacity
16 ksteps (C14), 32 ksteps (C30, C60)
Operating voltage range
12 A or less at 25°C (DC power)
Operation processing speed
Basic instruction 0.32 µs/step
Basic instructions
111
Allowed momentary power off time 10 ms or more
Ambient temperature
0 to +55°C
Storage temperature
-40 to +70°C
Ambient humidity
10 to 95% RH (at 25 °C, non-condensing)
Storage humidity
10 to 95% RH (at 25 °C, non-condensing)
Combined input/output terminals - Combined power and ground terminals,
2300 V
Breakdown voltage
AC*1
1 minute (AC power), 500 V
AC*1
1 minute (DC power)
Input terminals - Relay output terminals, 2300 V AC*1 1 minute
Input terminals - Transistor output terminals, 500 V AC*1 1 minute
500 V AC*1 1 minute (DC power)
Combined input/output terminals - Combined power and ground terminals,
100 MΩ or higher (500 V DC using an insulation resistance meter)
Input terminals - Output terminals, 100 MΩ or higher (500 V DC using an insulation resistance meter)
Power terminals - Ground terminals, 100 MΩ or higher (500 V DC using an insulation resistance meter)
Vibration resistance
Shock resistance
Noise immunity
Operating condition
EC Directive Compliance Standard
Level of contamination
Over-voltage category
5 to 9 Hz, single amplitude 3.5 mm/9 to 150 Hz, constant acceleration 9.8 m/s2,
1 sweep/min, 10 sweeps in each XYZ direction
147
m/s2
1500 V [P-P] pulse width 50 ns, 1 µs (AC power),
500 V [P-P] pulse width 50 ns, 1 µs (DC power)
(per noise simulator method) (power terminals)
No corrosive gas and no excessive dust
1760 points *4
External outputs (Y)
1760 points *4
Internal relay (R)
4096 points
Special internal relay (R)
192 points
Link relay (L)
2048 points
Timer/counter (T/C)
Total 1024 points: timer capable of counting
(1 ms, 10 ms, 100 ms, 1 s) x 32767
Counter capable of counting 1 to 32767
Data register (DT)
12285 words (C14), 32765 words (C30, C60)
Link data register (LD)
256 words
Special data register (DT)
374 words
Index register (I0 to ID)
14 words
Response OFF → ON
Master control relay (MCR)
256 points
time
Number of labels (LOOP)
256 labels
Number of differentiations
Up to program capacity
Number of stepladders
1000 stages
Conforming to EN61131-2
High-speed counter *5
2
II
Built-in (Transistor output): single-phase 8 ch (50 kHz x 4 ch + 10 kHz x 4 ch)
Built-in (Relay output): single-phase 8 ch (10 kHz x 8 ch)
Pulse I/O cassette: single-phase 2 ch (80 kHz x 2 ch)
*1 Cutoff current 5 mA
Pulse output *6
Built-in (Transistor output): 100 kHz x 2 ch + 20 kHz x 2 ch
Pulse I/O cassette: One unit (one axis) 100 kHz, or two units (two axes) 80 kHz
2. Power Consumption, Weight
Pulse catch input / interrupt input
Relay output type: Total 14 points (including the high-speed counter)
Transistor output type: Total 8 points (including the high-speed counter)
Periodical interrupt
0.5 ms to 30 s
Product name
Control Unit
Expansion I/O Unit
Expansion FP0 adapter
Input cassette
Output cassette
Pulse I/O cassette
Master memory cassette
Analog input cassette
Part number
Current consumption
26W or less*2
Approx. 280g or less
Potentiometer
2 points (0 to 1000) (C14, C30) 4 points (0 to 1000) (C60)
AFPX-C30❍❍
52W or less*2
Approx. 490g or less
Constant scan
Possible
AFPX-C60❍❍
64W or less*2
Approx. 780g or less
Real-time clock
Equipped (usable only when AFPX-MRTC is installed) *7
AFPX-E16❍❍
8W or less*2
Approx. 195g or less
AFPX-E30❍❍
less*2
45W or
Approx. 470g or less
0.24W or less*3
Approx. 65g
AFPX-IN8
1W or
less*2
Approx. 25g
AFPX-TR8
1W or less*2
Approx. 25g
AFPX-TR6P
1W or less*2
Approx. 25g
AFPX-PLS
2W or less*2
Approx. 25g
AFPX-MRTC
2W or less*2
Approx. 20g
AFPX-EFP0
AFPX-AD2
2W or
less*2
less*2
Approx. 25g
Approx. 25g
AFPX-A21
3W or
Analog output cassette
AFPX-DA2
5W or less*2
Communication
cassettes
Weight
AFPX-C14❍❍
Analog I/O cassette
Thermocouple input cassette
Approx. 25g
Flash ROM
backup *9
Backup by F12,
P13 commands Data register (32765 words)
Auto-backup
at power failure
Counter 16 points (1008 to 1023), Internal relay 128 points
(R2470 to R255F), Data register 55 words
The memory allocated in the storage area by the
system register (only when a battery is installed) *8
Battery backup
Before installing C14: 1230 days (actual operation 10 years at 25°C)
AFPX-MRTC
C30, C60: 990 days (actual operation 10 years at 25°C)
Battery life
(when no power
is supplied)
After installing
AFPX-MRTC
C14: 780 days (actual operation 10 years at 25°C)
C30, C60: 680 days (actual operation 10 years at 25°C)
(More than two batteries can be installed in C30 and C60.
In this case, the battery life is extended several times)
Min. ON voltage/ON current
Max. OFF voltage/OFF current
Input impedance
LED display
1a contact
Output points per common
Response time
Life time
C14, E16: 1 point or 3 points/common, C30, E30: 1 point or 4 points/common, C60: 1, 2 or 4 points/common
OFF → ON
Approx. 10 ms
ON → OFF
Approx. 8 ms
Mechanical
20 million operations or more (Operation frequency 180 times/min)
Electrical
100,000 operations or more (Operation frequency 20 times/min at the rated control capacity)
Surge absorber
None
Operating indicator
LED display
6. Transistor Output Specifications (Control unit, Expansion unit and Add-on cassette)
Item
Description
Control unit, Expansion unit
Open collector
Output type
Rated loadf voltage
Load voltage allowable range
NPN type: 5 to 24 V DC, PNP type: 24 V DC
24 V DC
NPN type: 4.75 to 26.4 V DC, PNP type: 21.6 to 26.4 V DC
21.6 to 26.4 V DC
0.5 A
NPN type: 0.3 A, PNP type: 0.5A
Max. load current
1.5 A
Max. inrush current
Output points per common
Response time
Add-on cassette (AFPX-TR8, AFPX-TR6P, AFPX-IN4T3)
Photocoupler
Insulation method
ON state voltage drop
Please refer to the user manual and specifications for further details.
1.0 ms or less
Same as above
2 A 250 V AC, 2 A 30 V DC (8 A or less/common)
Capable
Approx. 20g
Control unit X8 and after, Expansion unit
0.6 ms or less
Rated control capacity (Resistive load)
Rewriting in RUN mode
2W or less*2
1.0 ms or less
Description
AFPX-COM4
AFPX-COM6
Control unit X4 to X7
135 µs or less: Nominal input
50 µs or less: High-speed counter, pulse catch,
interruption input setting*1
Item
OFF state leakage current
*4 The actual usable number of points is restricted by the hardware.
*5 Specification at the rated input voltage of 24 V DC, 25°C. Frequency may be lower due to
the voltage and temperature.
*6 Max frequency may vary by the method of operation. Please refer to the manual for details.
*7 Calendar accuracy at 0°C: 119 sec/month or less, 25°C: 51 sec/month or less, 55°C: 148
sec/month or less (Real-time clock requires a battery.)
*8 When data is stored in the storage area while the battery is not installed, the data is not
cleared and the data value may be indefinite.
The same condition occurs when the battery is exhausted.
*9 The number of possible rewrites is 10,000 or less.
Control unit X0 to X3
135 µs or less: Nominal input
5 µs or less: High-speed counter, pulse catch,
interruption input setting*1
Output type
Max 16 units, link relay 1024 points, link register 128 words
(No data transfer or remote programming)
Approx. 25g
Approx. 6.8 kΩ
5. Relay Output Specifications (Control units, Expansion units)
PLC link function
3W or less*2
2.4V/1mA
*1 Specification at the rated input voltage of 24 V DC, 25°C.
AFPX-COM2
AFPX-COM5
0.6 ms or less: Normal input
50 µs or less: High-speed counter, pulse catch,
interruption input setting *1
ON → OFF
Capable (328 KB) (backup battery not required)
Approx. 20g
2.4 V/1.3 mA (Control unit X0 to X3)
2.4 V/1 mA (Control unit X4 and after, Expansion unit)
Approx. 3 kΩ (Control unit X0 to X3)
Approx. 5.1 kΩ (Control unit X0 to X7)
Approx. 5.1 kΩ (Control unit X4 to X7)
Approx. 5.6 kΩ (Control unit X8 and after, Expansion unit) Approx. 5.6 kΩ (Control unit X8 and after, Expansion unit)
Operating indicator
Comment storage
2W or less*2
19.2V/3mA
2.4 V/1 mA
0.6 ms or less
AFPX-COM1
AFPX-COM3
19.2 V/6 mA (Control unit X0 to X3)
19.2 V/3 mA (Control unit X4 and after, Expansion unit)
19.2 V/3 mA
Control unit X8 and after, Expansion unit
Watch dog timer, program syntax check
Approx. 25g
8 points/common (AFPX-IN8), 4 points/common (AFPX-IN4T3)
(Input power polarity either positive or negative)
Control unit X0 to X7
Capable (4 or 8 characters selectable)
1W or less*2
Approx. 3.5 mA
8 points/common (C14, E16) 16 points/common (C30, C60, E30)
Self-diagnosis function
AFPX-TC2
Approx. 8 mA (Control unit X0 to X3)
Approx. 4.7 mA (Control unit X4 to X7)
Input points per common
Password
*2 Power consumption by the AC power supply connected to the control unit
*3 Power consumption by the DC power supply connected to the expansion FP0 adapter
22
Number of interruption programs Relay output type: 15 programs (14 external, 1 constant)
Transistor output type: 9 programs (8 external, 1 constant)
24 V DC
21.6 to 26.4 V DC
Approx 4.3 mA (Control unit X8 and after, Expansion unit) Approx. 4.3 mA (Control unit X8 and after, Expansion unit)
216
500 subroutines
Add-on cassette (AFPX-IN8, AFPX-IN4T3)
Photo-coupler
Approx. 4.7 mA (Control unit X0 to X7)
External inputs (X)
Number of subroutines
Description
Relay output (control unit and expansion unit) Transistor output (control unit and expansion unit)
Rated input current
Applied instructions
Power terminals - Ground terminals, 1500 V AC*1 1 minute (AC power),
Insulation resistance
Item
Program method
100 to 240 V AC (AC power), 24 V DC (DC power)
Operating voltage range 85 to 264 V AC (AC power), 20.4 to 28.8 V DC (DC power)
Service power output
4. Input Specifications (Control unit, Expansion unit and Add-on cassette)
Specifications
C14: 6 points/common, E16: 8 points/common, C30, C60, E30: 8 or 6 points/common
TR8: 8 points/common, TR6P: 6 points/common, IN4T3: 3 points/common
1 µA or less
0.3 V DC or less
1.5 V DC or less
OFF → ON
1 ms or less*2
0.1 ms or less
ON → OFF
1 ms or less*2
0.8 ms or less
Voltage range for external power supply
21.6 to 26.4 V DC
—
Surge absorber
Zener diode
Operating indicator
LED display
*2 Please refer to the user manual for Y0 to Y7 of the transistor output type.
23
Specifications
Specifications
3. Controls Specifications
1. General Specifications
Item
Rated voltage
Description
Item
Rush current
Relay symbol method
Control method
Cyclic operation method
Insulation method
C14: 24V DC/0.15A, C30 and C60: 24V DC/0.4A
Program memory
Flash ROM built-in (no battery backup required)
Rated input voltage
40 A or less (C14), 45 A or less (C30, C60) at 25°C (AC power)
Program capacity
16 ksteps (C14), 32 ksteps (C30, C60)
Operating voltage range
12 A or less at 25°C (DC power)
Operation processing speed
Basic instruction 0.32 µs/step
Basic instructions
111
Allowed momentary power off time 10 ms or more
Ambient temperature
0 to +55°C
Storage temperature
-40 to +70°C
Ambient humidity
10 to 95% RH (at 25 °C, non-condensing)
Storage humidity
10 to 95% RH (at 25 °C, non-condensing)
Combined input/output terminals - Combined power and ground terminals,
2300 V
Breakdown voltage
AC*1
1 minute (AC power), 500 V
AC*1
1 minute (DC power)
Input terminals - Relay output terminals, 2300 V AC*1 1 minute
Input terminals - Transistor output terminals, 500 V AC*1 1 minute
500 V AC*1 1 minute (DC power)
Combined input/output terminals - Combined power and ground terminals,
100 MΩ or higher (500 V DC using an insulation resistance meter)
Input terminals - Output terminals, 100 MΩ or higher (500 V DC using an insulation resistance meter)
Power terminals - Ground terminals, 100 MΩ or higher (500 V DC using an insulation resistance meter)
Vibration resistance
Shock resistance
Noise immunity
Operating condition
EC Directive Compliance Standard
Level of contamination
Over-voltage category
5 to 9 Hz, single amplitude 3.5 mm/9 to 150 Hz, constant acceleration 9.8 m/s2,
1 sweep/min, 10 sweeps in each XYZ direction
147
m/s2
1500 V [P-P] pulse width 50 ns, 1 µs (AC power),
500 V [P-P] pulse width 50 ns, 1 µs (DC power)
(per noise simulator method) (power terminals)
No corrosive gas and no excessive dust
1760 points *4
External outputs (Y)
1760 points *4
Internal relay (R)
4096 points
Special internal relay (R)
192 points
Link relay (L)
2048 points
Timer/counter (T/C)
Total 1024 points: timer capable of counting
(1 ms, 10 ms, 100 ms, 1 s) x 32767
Counter capable of counting 1 to 32767
Data register (DT)
12285 words (C14), 32765 words (C30, C60)
Link data register (LD)
256 words
Special data register (DT)
374 words
Index register (I0 to ID)
14 words
Response OFF → ON
Master control relay (MCR)
256 points
time
Number of labels (LOOP)
256 labels
Number of differentiations
Up to program capacity
Number of stepladders
1000 stages
Conforming to EN61131-2
High-speed counter *5
2
II
Built-in (Transistor output): single-phase 8 ch (50 kHz x 4 ch + 10 kHz x 4 ch)
Built-in (Relay output): single-phase 8 ch (10 kHz x 8 ch)
Pulse I/O cassette: single-phase 2 ch (80 kHz x 2 ch)
*1 Cutoff current 5 mA
Pulse output *6
Built-in (Transistor output): 100 kHz x 2 ch + 20 kHz x 2 ch
Pulse I/O cassette: One unit (one axis) 100 kHz, or two units (two axes) 80 kHz
2. Power Consumption, Weight
Pulse catch input / interrupt input
Relay output type: Total 14 points (including the high-speed counter)
Transistor output type: Total 8 points (including the high-speed counter)
Periodical interrupt
0.5 ms to 30 s
Product name
Control Unit
Expansion I/O Unit
Expansion FP0 adapter
Input cassette
Output cassette
Pulse I/O cassette
Master memory cassette
Analog input cassette
Part number
Current consumption
26W or less*2
Approx. 280g or less
Potentiometer
2 points (0 to 1000) (C14, C30) 4 points (0 to 1000) (C60)
AFPX-C30❍❍
52W or less*2
Approx. 490g or less
Constant scan
Possible
AFPX-C60❍❍
64W or less*2
Approx. 780g or less
Real-time clock
Equipped (usable only when AFPX-MRTC is installed) *7
AFPX-E16❍❍
8W or less*2
Approx. 195g or less
AFPX-E30❍❍
less*2
45W or
Approx. 470g or less
0.24W or less*3
Approx. 65g
AFPX-IN8
1W or
less*2
Approx. 25g
AFPX-TR8
1W or less*2
Approx. 25g
AFPX-TR6P
1W or less*2
Approx. 25g
AFPX-PLS
2W or less*2
Approx. 25g
AFPX-MRTC
2W or less*2
Approx. 20g
AFPX-EFP0
AFPX-AD2
2W or
less*2
less*2
Approx. 25g
Approx. 25g
AFPX-A21
3W or
Analog output cassette
AFPX-DA2
5W or less*2
Communication
cassettes
Weight
AFPX-C14❍❍
Analog I/O cassette
Thermocouple input cassette
Approx. 25g
Flash ROM
backup *9
Backup by F12,
P13 commands Data register (32765 words)
Auto-backup
at power failure
Counter 16 points (1008 to 1023), Internal relay 128 points
(R2470 to R255F), Data register 55 words
The memory allocated in the storage area by the
system register (only when a battery is installed) *8
Battery backup
Before installing C14: 1230 days (actual operation 10 years at 25°C)
AFPX-MRTC
C30, C60: 990 days (actual operation 10 years at 25°C)
Battery life
(when no power
is supplied)
After installing
AFPX-MRTC
C14: 780 days (actual operation 10 years at 25°C)
C30, C60: 680 days (actual operation 10 years at 25°C)
(More than two batteries can be installed in C30 and C60.
In this case, the battery life is extended several times)
Min. ON voltage/ON current
Max. OFF voltage/OFF current
Input impedance
LED display
1a contact
Output points per common
Response time
Life time
C14, E16: 1 point or 3 points/common, C30, E30: 1 point or 4 points/common, C60: 1, 2 or 4 points/common
OFF → ON
Approx. 10 ms
ON → OFF
Approx. 8 ms
Mechanical
20 million operations or more (Operation frequency 180 times/min)
Electrical
100,000 operations or more (Operation frequency 20 times/min at the rated control capacity)
Surge absorber
None
Operating indicator
LED display
6. Transistor Output Specifications (Control unit, Expansion unit and Add-on cassette)
Item
Description
Control unit, Expansion unit
Open collector
Output type
Rated loadf voltage
Load voltage allowable range
NPN type: 5 to 24 V DC, PNP type: 24 V DC
24 V DC
NPN type: 4.75 to 26.4 V DC, PNP type: 21.6 to 26.4 V DC
21.6 to 26.4 V DC
0.5 A
NPN type: 0.3 A, PNP type: 0.5A
Max. load current
1.5 A
Max. inrush current
Output points per common
Response time
Add-on cassette (AFPX-TR8, AFPX-TR6P, AFPX-IN4T3)
Photocoupler
Insulation method
ON state voltage drop
Please refer to the user manual and specifications for further details.
1.0 ms or less
Same as above
2 A 250 V AC, 2 A 30 V DC (8 A or less/common)
Capable
Approx. 20g
Control unit X8 and after, Expansion unit
0.6 ms or less
Rated control capacity (Resistive load)
Rewriting in RUN mode
2W or less*2
1.0 ms or less
Description
AFPX-COM4
AFPX-COM6
Control unit X4 to X7
135 µs or less: Nominal input
50 µs or less: High-speed counter, pulse catch,
interruption input setting*1
Item
OFF state leakage current
*4 The actual usable number of points is restricted by the hardware.
*5 Specification at the rated input voltage of 24 V DC, 25°C. Frequency may be lower due to
the voltage and temperature.
*6 Max frequency may vary by the method of operation. Please refer to the manual for details.
*7 Calendar accuracy at 0°C: 119 sec/month or less, 25°C: 51 sec/month or less, 55°C: 148
sec/month or less (Real-time clock requires a battery.)
*8 When data is stored in the storage area while the battery is not installed, the data is not
cleared and the data value may be indefinite.
The same condition occurs when the battery is exhausted.
*9 The number of possible rewrites is 10,000 or less.
Control unit X0 to X3
135 µs or less: Nominal input
5 µs or less: High-speed counter, pulse catch,
interruption input setting*1
Output type
Max 16 units, link relay 1024 points, link register 128 words
(No data transfer or remote programming)
Approx. 25g
Approx. 6.8 kΩ
5. Relay Output Specifications (Control units, Expansion units)
PLC link function
3W or less*2
2.4V/1mA
*1 Specification at the rated input voltage of 24 V DC, 25°C.
AFPX-COM2
AFPX-COM5
0.6 ms or less: Normal input
50 µs or less: High-speed counter, pulse catch,
interruption input setting *1
ON → OFF
Capable (328 KB) (backup battery not required)
Approx. 20g
2.4 V/1.3 mA (Control unit X0 to X3)
2.4 V/1 mA (Control unit X4 and after, Expansion unit)
Approx. 3 kΩ (Control unit X0 to X3)
Approx. 5.1 kΩ (Control unit X0 to X7)
Approx. 5.1 kΩ (Control unit X4 to X7)
Approx. 5.6 kΩ (Control unit X8 and after, Expansion unit) Approx. 5.6 kΩ (Control unit X8 and after, Expansion unit)
Operating indicator
Comment storage
2W or less*2
19.2V/3mA
2.4 V/1 mA
0.6 ms or less
AFPX-COM1
AFPX-COM3
19.2 V/6 mA (Control unit X0 to X3)
19.2 V/3 mA (Control unit X4 and after, Expansion unit)
19.2 V/3 mA
Control unit X8 and after, Expansion unit
Watch dog timer, program syntax check
Approx. 25g
8 points/common (AFPX-IN8), 4 points/common (AFPX-IN4T3)
(Input power polarity either positive or negative)
Control unit X0 to X7
Capable (4 or 8 characters selectable)
1W or less*2
Approx. 3.5 mA
8 points/common (C14, E16) 16 points/common (C30, C60, E30)
Self-diagnosis function
AFPX-TC2
Approx. 8 mA (Control unit X0 to X3)
Approx. 4.7 mA (Control unit X4 to X7)
Input points per common
Password
*2 Power consumption by the AC power supply connected to the control unit
*3 Power consumption by the DC power supply connected to the expansion FP0 adapter
22
Number of interruption programs Relay output type: 15 programs (14 external, 1 constant)
Transistor output type: 9 programs (8 external, 1 constant)
24 V DC
21.6 to 26.4 V DC
Approx 4.3 mA (Control unit X8 and after, Expansion unit) Approx. 4.3 mA (Control unit X8 and after, Expansion unit)
216
500 subroutines
Add-on cassette (AFPX-IN8, AFPX-IN4T3)
Photo-coupler
Approx. 4.7 mA (Control unit X0 to X7)
External inputs (X)
Number of subroutines
Description
Relay output (control unit and expansion unit) Transistor output (control unit and expansion unit)
Rated input current
Applied instructions
Power terminals - Ground terminals, 1500 V AC*1 1 minute (AC power),
Insulation resistance
Item
Program method
100 to 240 V AC (AC power), 24 V DC (DC power)
Operating voltage range 85 to 264 V AC (AC power), 20.4 to 28.8 V DC (DC power)
Service power output
4. Input Specifications (Control unit, Expansion unit and Add-on cassette)
Specifications
C14: 6 points/common, E16: 8 points/common, C30, C60, E30: 8 or 6 points/common
TR8: 8 points/common, TR6P: 6 points/common, IN4T3: 3 points/common
1 µA or less
0.3 V DC or less
1.5 V DC or less
OFF → ON
1 ms or less*2
0.1 ms or less
ON → OFF
1 ms or less*2
0.8 ms or less
Voltage range for external power supply
21.6 to 26.4 V DC
—
Surge absorber
Zener diode
Operating indicator
LED display
*2 Please refer to the user manual for Y0 to Y7 of the transistor output type.
23
■ FP-X Control Unit Dimensions (Unit: mm)
Dimensions when add-on cassettes
(function and communication) are installed
●AFPX-C14 ∗ ∗ (The same dimensions apply to the expansion I/O unit AFPX-E16∗)
COM
Status display LED
N
X5
X3
X0
X2
X4
X7
X6
PROG. ERR.
0
X 4
0
Y 4
Programmable Controller
45
L
RUN
Input/output display LED
Application cassette
Communication cassette
X1
FP-X
60
3
7
3
5
90
Panasonic
RUN
PROG.
Mode selection switch
RUN/PROG.
FP-X C14
min.
max.
V0
V1
45
Analog volume
Tool port connector
0V
Y0
24V
Y2
Y1
C0
C1
C2
Y5
Y3
C3
Y4
13.6
79
3.5
Application cassette
Communication cassette
Battery
Expansion unit connector
ARCT1B287E
DIN hook
Cassette attachment area 1
8.6
79
*AFPX-COM5 Communication Cassette (Ethernet type): 5 mm higher
●AFPX-C30 ∗ ∗ (The same dimensions apply to the expansion I/O unit AFPX-E30∗∗)
100
Status display LED
N COM
L
COM
RUN
Input/output display LED
Y
X3
X2
X5
X4
X7
X6
X9
X8
XB
XA
XD
XC
Mounting dimension diagram
XF
Strengthened Product Lineup
to Meet Diversified Demands
Mounting dimensions for expansion
L2
L2
XE
PROG. ERR.
0
8
0
8
X
X1
X0
7
F
7
D
Panasonic
90
FP-X C30
Mode selection switch
RUN/PROG.
RUN
PROG.
max.
8
H
min.
V0
Analog volume
V1
0V
USB connector
24V
Tool port connector
Y0
C0
Y1
C1
Y2
C2
C3
Y4
Y3
Y5
Y7
Y6
Y9
Y8
YA
C4
YC
YB
L2
52
C30, E30
92
C60
182
82
(mm)
2-M4 or 2-5 dia.
Application cassette
Battery
Expansion unit connector
●AFPX-C60 ∗ ∗
H
(Tolerance: ±0.5)
YD
Cassette attachment area 1 Cassette attachment area 2
Application cassette
Communication cassette
Battery
Type
C14, E16
190
N COM
L
COM
RUN
X
Y
Mode selection switch
RUN/PROG.
X0
PROG.
X3
X2
X5
X4
XA
XF
XD
COM
NC
XE
XC
COM
COM
X11
X10
COM
X13
X15
X14
X12
X19
X17
X16
X18
X1B
X1A
X1D
X1C
X1F
X1E
ERR.
F
1F
D
1D
FP-X C60
V1
V2
max.
V3
0V
Tool port connector
X8
XB
max.
V0
min.
USB connector
X9
Panasonic
min.
24V
X6
7 8
17 18
7 8
17 18
0
10
0
10
RUN
PROG.
Analog volume
X7
Y0
C0
Y1
C1
Y2
C2
C3
Y4
Y3
Y5
Y7
Y6
Y9
Y8
YA
C4
Y10
YC
YB
YD
Cassette attachment area 1
Application cassette
Communication cassette
Battery
C0
Y11
C1
C2
Y12
Y13
C3
Y14
C4
C5
Y15
Y17
Y16
Y1A
Y19
Y18
C6
Y1C
Y1B
Cassette attachment area 2
Application cassette
Battery
Y1D
Expansion connector part
Battery
Expansion unit connector
■ FP-X Expansion FP0 Adapter Dimensions (Unit: mm)
( 0.5 )
25
60
POWER
I/F
L
ERROR
45
Status
display LED
(7)
Panasonic
Expansion connector
90
AFPX-EFP0
FP0-A80
When the expansion
connector is
attached
45
Input/output display LED
X1
90
Status display LED
Appearance when mounted
with a C14 control unit
3.5
DIN hook
Power connector 24 V DC
Expansion hook
These materials are printed on ECF pulp.
These materials are printed with earth-friendly vegetable-based (soybean oil) ink.
Please contact ..........
Matsushita Electric Works, Ltd.
Automation Controls Business Unit
Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan
Telephone: +81-6-6908-1050
Facsimile: +81-6-6908-5781
http://www.mew.co.jp/ac/e
FP-X Programmable Controller
ARCT1B287E '07.5
All Rights Reserved © 2007 COPYRIGHT Matsushita Electric Works, Ltd.
ARCT1B287E 200705-5YT
Specifications are subject to change without notice.
Printed in Japan.
http://www.mew.co.jp/ac/e
Matsushita Electric Works, Ltd.