Signal Relays ( 2 A or less )
GQ RELAYS
Product Catalog
2022.10
Signal Relays ( 2 A or less )
GQ RELAYS
High sensitivity, 100 mW operating power, 2 Form C, 2 A, compact size and flat relays
FEATURES
Protective construction:Sealed type
● High sensitivity:
Rated operating power 100 mW ( High
sensitivity single side stable )
10.6
7.2
● Compact size and flat:
Width ( 7.2 mm ) × Length ( 10.6 mm ) × Height ( 5.2 mm )
5.2
10.6
● Compliant with Telcordia standard:
Surge withstand voltage 2,500 V ( between contact and coil )
7.2
5.4
● Confort to FCC Part68:
Surge withstand voltage 1,500 V ( between open contacts )
TYPICAL APPLICATIONS
(Unit:mm)
● Telecommunications and measurement
equipment
● Telephone related equipment
● Household electrical appliance and Audio
Visual equipment
● Security equipment
ORDERING INFORMATION ( PART NO. )
AGQ 2
0
Operating function
0 : Single side stable
1 : 1 coil latching
6 : High sensitivity single side stable
Contact arrangement
2 : 2 Form C
Packing style*1
Nil : Tube packing
X : Tape and reel packing (picked from 1/2/3/4-pin side)
Z : Tape and reel packing (picked from 5/6/7/8-pin side)
W : Tape and reel packing (picked from the 1/2/3/4-pin side)
With humidity indicator and silica gel in moisture proof bag*3
Y : Tape and reel packing (picked from the 5/6/7/8-pin side)
With humidity indicator and silica gel in moisture proof bag*3
Terminal shape
Nil : Standard PC board terminal
A : Surface-mount terminal A type
S : Surface-mount terminal S type
Type of operation
0 : Standard type(B.B.M.)
Rated coil voltage(DC)*2
1H : 1.5V, 03 : 3V, 4H : 4.5V,
12 : 12V, 24 : 24V
(H=0.5)
06 : 6V,
09 : 9V,
*1. The“W”and“Y”at the end of the part number only appears on the inner and outer packing.
It does not appear on the relay itself.
*2. Please inquire if you require a relay, between 1.5 and 24 V DC, with a voltage not listed.
*3. Each reel is packed with humidity indicators and silica gel in the moisuture proof pack.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー1ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
TYPES
■ PC board terminal
● Tube packing
Contact
arrangement
Rated coil
voltage
Part No.
Standard packing
Single side stable
1 coil latching
High sensitivity
single side stable
1.5 V DC
AGQ2001H
AGQ2101H
AGQ2601H
3
V DC
AGQ20003
AGQ21003
AGQ26003
4.5 V DC
AGQ2004H
AGQ2104H
AGQ2604H
6
V DC
AGQ20006
AGQ21006
AGQ26006
9
V DC
AGQ20009
AGQ21009
AGQ26009
12
V DC
AGQ20012
AGQ21012
AGQ26012
24
V DC
AGQ20024
AGQ21024
AGQ26024
2 Form C
Carton
( 1 Tube packing )
Outer carton
50 pcs.
1,000 pcs.
■ Surface-mount terminal
● Tube packing
Contact
arrangement
2 Form C
Rated coil
voltage
Part No.
Standard packing
Single side stable
1 coil latching
High sensitivity
single side stable
1.5 V DC
AGQ200*1H
AGQ210*1H
AGQ260*1H
3
V DC
AGQ200*03
AGQ210*03
AGQ260*03
4.5 V DC
AGQ200*4H
AGQ210*4H
AGQ260*4H
6
V DC
AGQ200*06
AGQ210*06
AGQ260*06
9
V DC
AGQ200*09
AGQ210*09
AGQ260*09
12
V DC
AGQ200*12
AGQ210*12
AGQ260*12
24
V DC
AGQ200*24
AGQ210*24
AGQ260*24
Carton
( 1 Tube packing )
Outer carton
50 pcs.
1,000 pcs.
Note) " * " : For each surface-mount terminal identitication, input the following letter. A type: A, S type: S.
■ Tape and reel packing: Z
Contact
arrangement
2 Form C
Rated coil
voltage
Part No.
Standard packing
Single side stable
1 coil latching
High sensitivity
single side stable
1.5 V DC
AGQ200*1HZ
AGQ210*1HZ
AGQ260*1HZ
3
V DC
AGQ200*03Z
AGQ210*03Z
AGQ260*03Z
4.5 V DC
AGQ200*4HZ
AGQ210*4HZ
AGQ260*4HZ
6
V DC
AGQ200*06Z
AGQ210*06Z
AGQ260*06Z
9
V DC
AGQ200*09Z
AGQ210*09Z
AGQ260*09Z
12
V DC
AGQ200*12Z
AGQ210*12Z
AGQ260*12Z
24
V DC
AGQ200*24Z
AGQ210*24Z
AGQ260*24Z
Carton
( 1 Reel packing )
Outer carton
900 pcs.
1,800 pcs.
Notes) 1: " * " : For each surface-mount terminal identitication, input the following letter. A type: A, S type: S.
2. For taping packaging X, W, and Y, change " Z " at the end of the part number to " X ", " W ", and " Y ".
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー2ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
RATING
■ Coil data
• Operating characteristics such as " Operate voltage " and " Release voltage " are influenced by mounting conditions or
ambient temperature, etc.
Therefore, please use the relay within ±5 % of rated coil voltage.
• " Initial " means the condition of products at the time of delivery.
● Single side stable
Rated coil
voltage
Operate voltage*
( at 20 ℃ )
Release voltage*
( at 20 ℃ )
Rated operating current
( ±10 %, at 20 ℃ )
Coil resistance
( ±10 %, at 20 ℃ )
1.5 V DC
93.8 mA
16
3
46.7 mA
64.2 Ω
V DC
4.5 V DC
6
V DC
Max. 75 % V of
rated coil voltage
( Initial )
Min. 10 % V of
rated coil voltage
( Initial )
31
Rated operating
power
Max. allowable voltage
( at 20 ℃ )
140 mW
150 % V of
rated coil voltage
230 mW
120 % V of
rated coil voltage
Rated operating
power
Max. allowable voltage
( at 20 ℃ )
100 mW
150 % V of
rated coil voltage
Ω
mA
145
Ω
23.3 mA
257
Ω
9
V DC
15.5 mA
579
Ω
12
V DC
11.7 mA
1,028
Ω
24
V DC
9.6 mA
2,504
Ω
* square, pulse drive ( JIS C 5442 )
● 1 coil latching
Rated coil
voltage
Set voltage*
( at 20 ℃ )
Reset voltage*
( at 20 ℃ )
Rated operating current
( ±10 %, at 20 ℃ )
Coil resistance
( ±10 %, at 20 ℃ )
1.5 V DC
66.7 mA
22.5 Ω
3
V DC
33.3 mA
90
4.5 V DC
22.2 mA
202.5 Ω
16.7 mA
360
Ω
6
V DC
Max. 75 % V of
rated coil voltage
( Initial )
Max. 75 % V of
rated coil voltage
( Initial )
Ω
9
V DC
11.1 mA
810
Ω
12
V DC
8.3 mA
1,440
Ω
24
V DC
5
4,800
Ω
mA
120 mW
* square, pulse drive ( JIS C 5442 )
● High sensitivity single side stable
Rated coil
voltage
Operate voltage*
( at 20 ℃ )
Release voltage*
( at 20 ℃ )
Rated operating current
( ±10 %, at 20 ℃ )
Coil resistance
( ±10 %, at 20 ℃ )
1.5 V DC
66.7 mA
22.5 Ω
3
V DC
33.3 mA
90
4.5 V DC
22.2 mA
202.5 Ω
16.7 mA
360
Ω
6
V DC
Max. 80 % V of
rated coil voltage
( Initial )
Min. 10 % V of
rated coil voltage
( Initial )
Max. allowable voltage
( at 20 ℃ )
100 mW
150 % V of
rated coil voltage
120 mW
120 % V of
rated coil voltage
Ω
9
V DC
11.1 mA
810
Ω
12
V DC
8.3 mA
1,440
Ω
24
V DC
5
4,800
Ω
mA
Rated operating
power
* square, pulse drive ( JIS C 5442 )
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー3ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
■ Specifications
Item
Contact data
2 Form C
Contact resistance
( Initial )
Max. 100 mΩ ( by voltage drop 6 V DC 1 A )
Contact material
AgPd + Au-clad ( Stationary contact ), AgPd ( Movable contact )
Contact rating
( resistive )
2 A 30 V DC, 0.3 A 125 V AC
Max. switching power
( resistive )
60 W ( DC ), 37.5 VA ( AC )
Max. switching voltage
110 V DC, 125 V AC
Max. switching current
2 A ( DC ), 2 A ( AC )
Min. switching load
( reference value )*1
10 µA 10 mV DC
Insulation resistance ( Initial )
Dielectric
strength
( Initial )
Specifications
Contact arrangement
Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. )
Between open contacts
750 Vrms for 1 min ( detection current: 10 mA )
Between contact and coil
1,500 Vrms for 1 min ( detection current: 10 mA )
Between contact sets
1,000 Vrms for 1 min ( detection current: 10 mA )
Surge
withstand
voltage
( Initial )
Between open contacts
1,500 V 10 × 160 µs
Between contact and coil
2,500 V 2 × 10 µs
Time
characteristics
( Initial )
Operate [ Set ] time
Max. 4 ms at rated coil voltage ( at 20 ℃, without bounce )
[ Max. 4 ms ( at 20 ℃, without bounce ) ]
Release [ Reset ] time
Max. 4 ms at rated coil voltage (at 20 ℃, without bounce, without diode)
[ Max. 4 ms (at 20 ℃, without bounce ) ]
Shock
resistance
Functional
750 m/s2 ( half-sine shock pulse: 6 ms, detection time: 10 µs )
Destructive
1,000 m/s2 ( half-sine shock pulse: 6 ms )
Vibration
resistance
Functional
10 to 55 Hz ( at double amplitude of: 3.3 mm, detection time: 10 µs )
Destructive
10 to 55 Hz ( at double amplitude of: 5 mm )
Expected life
Mechanical life
Min. 50 x 106 ope. ( Switching frequency: at 180 times/min )
Conditions
Conditions for usage,
transport and storage*2
Ambient temperature: −40 to +85 ℃ ( Single side stable, 1 coil latching ),
−40 to +70 ℃ ( High sensitivity single side stable )
( Allowable temperature is from −40 to +70 ℃ at our standard packing condition. )
Humidity: 5 to 85 % RH ( Avoid icing and condensation )
Unit weight
Approx. 1 g
Note) For AC load, please inquire our sales representative for details.
*1: This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2: For ambient temperature, please refer to the " GUIDELINES FOR RELAY USAGE ".
■ Electrical life
Conditions: resistive load, switching frequency at 20 times/minute
Type
Switching capacity
2 Form C
Number of operations
A 30 V DC
Min. 100 × 103 ope.
0.3 A 125 V AC
Min. 100 × 103 ope.
2
Min. 50 × 103 ope.
1
A 30 V DC
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー4ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
REFERENCE DATA
1. Max. switching capacity
2. Switching life curve
* Max. switching capacity is 2A 30V DC.
100
DC resistive load
0.3
0
AC resistive load
0
30
50
30
10
5
0
110 125
Contact voltage, V
3. Coil temperature rise value
( Average )
125V AC
resistive load
30V DC resistive load
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4
Contact capacity, A
4. Ambient temperature characteristics
( Average )
Tested sample:AGQ200A4H, AGQ200A24, 6 pcs.
Point measured:Inside the coil
Ambient temperature:Room temperature
Tested sample:AGQ200A4H, 6 pcs.
Temperature rise, °
C
60
24V DC
50
40
Rate of
change, %V
70
2A
1A
0A
30
Release
voltage
20
0
0
-40 -20
Operate voltage
4.5V DC
10
0
100
110 120 130 140 150
Coil applied voltage, %V
Tested sample:AGQ200A4H, 15 pcs.
Operating speed:180 cpm
50
100
40
90
30
80
20
Ave.
Ave.
10
2A
1A
0A
160
5. Mechanical life
20 40
-10
60 80
Ambient
temperature, °
C
Voltage, V
No. of operations, ×10 4
Contact current, A
2
Operate voltage
70
Max.
60
Min.
50
40
-20
30
-30
20
-40
10
-50
0
Release voltage
Max.
Min.
0
10
20
30
40
No. of operations, ×10 4
50
6. Electrical life test ( 1 A 30 V DC resistive load )
Change of Operate and Release voltage
Change of contact resistance
100
100
90
90
80
Operate voltage
70
60
Max.
Min.
50
40
Release voltage
30
20
Max.
Min.
10
0
Contact resistance, mΩ
Ratio against the rated voltage, %V
Tested sample:AGQ200A4H, 6 pcs.
Operating speed:20 cpm
N.O. contact
N.C. contact
80
70
60
50
Ave.
Ave.
40
30
20
10
0
5
No. of operations, ×10 4
10
0
0
5
No. of operations, ×10 4
10
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー5ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
7-1. Operate and release time
( without diode )
7-2. Operate and release time
( with diode )
Tested sample:AGQ2004H, 10 pcs.
Tested sample:AGQ2004H, 10 pcs.
Operate time
Release time
2.5
Max.
2
Min.
1.5
Max.
Min.
1
3
Operate and release time, ms
Operate and release time, ms
3
0.5
80
90
100
110
120
Coil applied voltage, %V
Rate of change, %V
Tested sample:AGQ20012, 6 pcs.
Rate of change, %V
Operate time
Release time
2.5
[m/s2]
1,000 Y
Z
X
Min.
Max.
Min.
1.5
1
Z’
X’
ZX
ON ON
0
Operate voltage
ℓ ℓ
ON
-5
-10
10
OFF OFF
5
Release voltage
0
ℓ ℓ
OFF
-5
0
2
4
Z’
Y
Y’
0
80
90
100
110
120
Coil applied voltage, %V
X’
Y’
130
9-2. Influence of proximity mounting
Tested sample:AGQ20012, 6 pcs.
10
5
Deenergized condition
Energized condition
Max.
2
0
130
6
8
10 12
Inter-relay distance ℓ, mm
Rate of change, %V
0
9-1. Influence of proximity mounting
-10
Tested sample:AGQ2004H, 10 pcs.
0.5
Rate of change, %V
0
8. Functional shock
10
ON
5
ℓ
0
Operate voltage
-5
ON
-10
10
OFF
5
ℓ
Release voltage
0
ℓ
OFF
-5
-10
ℓ
ON
OFF
0
2
4
6
8
10 12
Inter-relay distance ℓ, mm
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー6ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
DIMENSIONS ( Unit: mm )
CAD The CAD data of the products with a " CAD " mark can be downloaded from our Website.
■ PC board terminal
CAD
External dimensions
Recommended PC board pattern
( BOTTOM VIEW )
2.2
2.2
5.2±0.2
3.2
7.2±0.3
5.08
10.6±0.3
Schematic
( BOTTOM VIEW )
Single side stable
High sensitivity single side stable
( De-energize )
1
2
3
4
+
φ0.85
Tolerance:±0.1
2.2±0.15
2.2±0.15
8 7 6 5
Direction indication
0.2±0.1
5.08±0.15
3.5±0.3
0.4±0.1
3.2±0.15
1 coil latching
( Reset )
1
2
3
4
+
8 7 6 5
Direction indication
■ Surface-mount terminal
CAD
Recommended
PC board pattern
( TOP VIEW )
External dimensions
7.2±0.3
Schematic
( TOP VIEW )
Single side stable
High sensitivity single side stable
( De-energize )
2.2
2.2
6.74
2.66
10.6±0.3
A
3.2
Max. 5.4
Type
0.8
0.4±0.1
3.2±0.15
2.2±0.15
2.2±0.15
8
7
6
5
+
1 2 3 4
Direction indication
Tolerance : ±0.1
0.2±0.1
5.08±0.15
1 coil latching
( Reset )
8.4±0.3
8
7
6
5
+
7.2±0.3
2.2
2.2
1 2 3 4
Direction indication
6.14
2.06
S
Max. 5.4
10.6±0.3
3.2
0.8
0.4±0.1
3.2±0.15
2.2±0.15
2.2±0.15
0.2±0.1
7.2±0.3
5.08±0.15
Tolerance : ±0.1
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー7ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
PACKING STYLE ( Unit: mm )
■ Tube packing
1) The relay is packing in a tube with the relay orientation
mark on the left side,as shown in the figure below.
Be sure to maintain relays in the correct orientation
when mounting on PC boards.
2) Conditions for operation, transport and storage: ‒40 to 70 ℃.
Orientation(indicates PIN No.1)stripe
Stopper(green)
Stopper(red)
■ Taping packaging
2) Dimensions of plastic reel
1) Tape dimensions
A Type
12
4
φ2
9
0.4
2±0.5
Max. 6.55
φ330±2
2
φ80±1
φ1.5
(Z type)
11.1
11.5 1.75
24±0.3
Relay polarity bar
φ21±0.8
+0.1
0
GQ relays
Tape coming out direction
General tolerance : ±0.1
φ13±0.2
24.4+ 20
2±0.2
0.1
φ1.5+
0
2
4
φ2
11.1
Relay polarity bar
(Z type)
12
7.8
11.5 1.75
24±0.3
S Type
0.4
3) Conditions for operation, transport and storage: ‒40 to 70 ℃.
Max. 6.55
GQ relays
Tape coming out direction
General tolerance : ±0.1
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー8ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
EXAMPLE OF RECOMMENDED SOLDERING CONDITIONS
■ For cautions for use, please read " Relay Soldering and Cleaning Guidelines " and " SMT Soldering
Guidelines ".
■ PC board terminal
In case of hand soldering, the following conditions should be observed.
The effect on the relay depends on the PC board used. Please verify the actual PC board to be used.
● Automatic soldering ( Flow )
Recommended
conditions
Temperature
Preheating
Soldering
● Hand soldering
Time
Measurement
location
Recommended
conditions
Temperature
Time
Measurement
location
Max. 120 ℃
Within
120 seconds
Solder surface
terminal
Soldering
Max. 350 ℃
Within
3 seconds
Tip
temperature
260 ℃ ±5 ℃
Within
6 seconds
Solder
temperature
■ Surface-mount terminal
In case of automatic soldering ( reflow ), the following conditions should be observed.
● IRS ( infrared reflow soldering method ) heating conditions
Recommend conditions
Number of reflow
Measuring position
1 time
Surface of PC board where relay is mounted.
t4
T3
T2
T1
t1
t2
t3
t 1=60s to 120s
t 2=within 20s
t 3=within 30s
C)
t 4=within 10s(245 to 250°
T1=150 to 180°
C
C and higher
T2=230°
C max
T3=250°
● Mounting cautions
Cautions to observe when mounting temperature
increases in the relay are greatly dependent on the way
different parts are located a PC board and the heating
method of the reflow device. Therefore, please conduct
testing on the actual device beforehand after making sure
the parts soldered on the relay terminals and the top of
the relay case are within the temperature conditions.
Measuring position of temperature profile
Note
Note:7KHVROGHULQJWHPSHUDWXUHSURŏOH
indicates the pad temperature. In
some cases, the ambient
temperature may be greatly
LQFUHDVHG&KHFNIRUWKHVSHFLŏF
mounting condition.
■ Other things to observe
• Exceeding the stipulated conditions when soldering may
affect coaxial switch performance. Be sure to consult us
beforehand.
• Since thermal stress on a relay will depend on the PC
board and process conditions, please be sure to test using
the actual PC board.
• Creep-up, wettability and solder strength will differ
depending on changes in the mounting conditions and
type of solder. Please evaluate based on actual production
conditions.
• Only apply coating after the relay has returned to room
temperature.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー9ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
Signal Relays ( 2 A or less ) GQ RELAYS
SAFETY STANDARDS
Each standard may be updated at any time, so please check our Website for the latest information.
■ UL/C-UL (Approved)
File No.
E43149
Contact rating
■ CSA ( Approved )
Operations
2
A 30 V DC Resistive
50 × 103
40 ℃
1
A 30 V DC Resistive
100 × 103
40 ℃
6 × 103
85 ℃
0.3 A 110 V DC Resistive
30 × 103
40 ℃
0.3 A 125 V AC Resistive
100 × 103
40 ℃
0.5 A 60 V DC Resistive*
CSA standard approved by C-UL.
Ambient
temperature
*Single side stable type 1.5 to 12 V DC only
■ BSI ( Approved )
BSI standard approved by File No. VC667389
( basic insulation ).
GUIDELINES FOR USAGE
■ For cautions for use, please read " GUIDELINES FOR SIGNAL RELAYS USAGE " and " GUIDELINES FOR
RELAY USAGE ".
■ Cautions for usage of GQ relay
● Latching
• Use latching when conditions involve continuous
carrying current.
• Regarding the set and reset pulse time, for the purpose
of reliable operation under ambient temperature
fluctuations and different operating conditions, we
recommend setting the coil applied set and reset pulse
time to 10 ms or more at the rated coil voltage.
• The relay is shipped in the reset position. But jolts
during transport or impacts during installation can
change the reset position. It is, therefore, advisable to
build a circuit in which the relay can be initialized ( set
and reset ) just after turning on the power.
● Precautions for usage of automatic insertion machine
Set the chucking pressure of the pick-up mechanism
by the automatic mounting machine with the pressure
shown in table 1 to maintain the internal function of the
relay.
E
A
D
C
B
Please chuck the portion.
Avoid chucking the center of the
relay. In addition, excessive
chucking pressure to the pinpoint of
the relay should be also avoided.
Table 1: Chucking pressure
A to E direction
Max. 9.8 N ( 1 kgf )
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 10 ー
Panasonic Industry Co., Ltd. 2022
ASCTB7E 202210
GUIDELINES FOR SIGNAL RELAYS USAGE
■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE ".
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
PRECAUTIONS FOR COIL INPUT
■ Long term current carrying
■ Coil connection
A circuit that will be carrying a current continuously for
long periods without relay switching operation. ( circuits for
emergency lamps, alarm devices and error inspection that,
for example, revert only during malfunction and output
warnings with form B contacts )
Continuous,long-term current to the coil will facilitate
deterioration of coil insulation and characteristics due to
heating of the coil itself. For circuits such as these, please
use a magnetic-hold type latching relay. If you need to use
a single stable relay, use a sealed type relay that is not easily
affected by ambient conditions and make a failsafe circuit
design that considers the possibility of contact failure or
disconnection.
When connecting coils of polarized relays, please check coil
polarity ( +, − ) at the internal connection diagram
( Schematic ).
If any wrong connection is made, it may cause unexpected
malfunction, like abnormal heat, fire and so on, and circuit
do not work.
Avoid impressing voltages to the set coil and reset coil at the
same time.
■ DC Coil operating power
Steady state DC current should be applied to the coil.
The wave form should be rectangular. If it includes ripple,
the ripple factor should be less than 5 %. However,
please check with the actual circuit since the electrical
characteristics may vary.
The rated coil voltage should be applied to the coil and the
set/reset pulse time of latching type relay differs for each
relays, please refer to the relay's individual specifications.
■ Maximum allowable voltage and temperature rise
Proper usage requires that the rated coil voltage be
impressed on the coil.
Note, however, that if a voltage greater than or equal to the
maximum continuous voltage is impressed on the coil, the
coil may burn or its layers short due to the temperature rise.
Furthermore, do not exceed the usable ambient temperature
range listed in the catalog.
● Operate voltage change due to coil temperature rise
( hot start )
In DC relays, after continuous passage of current in the
coil, if the current is turned OFF, then immediately turned
ON again, due to the temperature rise in the coil, the
operate voltage will become somewhat higher. Also,
it will be the same as using it in a higher temperature
atmosphere.
The resistance/temperature relationship for copper wire is
about 0.4 % for 1 ℃, and with this ratio the coil resistance
increases.
That is, in order to operate of the relay, it is necessary
that the voltage be higher than the operate voltage and
the operate voltage rises in accordance with the increase
in the resistance value.
However, for some polarized relays, this rate of change is
considerably smaller.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 11 ー
Panasonic Industry Co., Ltd. 2022
ASCTB414E 202210
GUIDELINES FOR SIGNAL RELAYS USAGE
NOTES
■ Usage, Storage, and Transport Conditions
During usage, storage, or transportation, avoid locations
subject to direct sunlight and maintain normal temperature,
humidity, and pressure conditions.
The allowable specifications for environments suitable for
usage, storage, and transportation are given below.
1) Temperature:
The allowable temperature range differs for each relay,
so refer to the relay's individual specifications.
In addition, when transporting or storing relays while
they are tube packaged, there are cases when the
temperature may differ from the allowable range.
In this situation, be sure to consult the individual
specifications.
2) Humidity: 5 to 85% RH
The humidity range varies with the temperature.
Use within the range indicated in the graph.
( The allowable temperature depends on the relays. )
● Condensation
Condensation occurs when the ambient temperature
drops suddenly from a high temperature and humidity,
or the relay and microwave device is suddenly transferred
from a low ambient temperature to a high temperature
and humidity.
Condensation causes the failures like insulation
deterioration, wire disconnection and rust etc.
Panasonic Industry Co., Ltd. does not guarantee the
failures caused by condensation.
The heat conduction by the equipment may accelerate
the cooling of device itself, and the condensation may
occur.
Please conduct product evaluations in the worst condition
of the actual usage. ( Special attention should be paid
when high temperature heating parts are close to the
device. Also please consider the condensation may occur
inside of the device. )
Humidity (% RH)
● Icing
Condensation or other moisture may freeze on relays
when the temperature become lower than 0 ℃.
This icing causes the sticking of movable portion, the
operation delay and the contact conduction failure etc.
Panasonic Industry Co., Ltd. does not guarantee the
failures caused by the icing.
The heat conduction by the equipment may accelerate
the cooling of relay itself and the icing may occur.
Please conduct product evaluations in the worst condition
of the actual usage.
85
Allowable range
Avoid icing
when used at
temperatures
lower than 0°C
Avoid condensation when
used at temperatures higher
than 0°C
5
-40
0
85
Ambient temperature (℃)
3) Pressure: 86 to 106 kPa
● Low temperature and low humidity
The plastic becomes brittle if the switch is exposed to
a low temperature, low humidity environment for long
periods of time.
● High temperature and high humidity
Storage for extended periods of time ( including
transportation periods ) at high temperature or high
humidity levels or in atmospheres with organic gases
or sulfide gases may cause a sulfide film or oxide film
to form on the surfaces of the contacts and/or it may
interfere with the functions.
Check out the atmosphere in which the units are to be
stored and transported.
● Package
In terms of the packing format used, make every effort
to keep the effects of moisture, organic gases and sulfide
gases to the absolute minimum.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 12 ー
Panasonic Industry Co., Ltd. 2022
ASCTB414E 202210
GUIDELINES FOR SIGNAL RELAYS USAGE
● Storage requirements
Since the surface-mount terminal type is sensitive to
humidity it is packaged with tightly sealed anti-humidity
packaging. However, when storing, please be careful of
the following.
1) Please use promptly once the anti-humidity pack is
opened. ( within 72 hours, Max. 30 ℃ / 70% RH ).
If left with the pack open, the relay will absorb
moisture which will cause thermal stress when reflow
mounting and thus cause the case to expand. As a
result, the seal may break.
2) If relays will not be used within 72 hours, please store
relays in a humidity controlled desiccator or in an antihumidity bag to which silica gel has been added.
4 ) The following cautionary label is affixed to the antihumidity pack.
* If the relay is to be soldered after it has been exposed to excessive
humidity atmosphere, cracks and leaks can occur.
Be sure to mount the relay under the required mounting conditions.
3) When relays ( which is packaged with humidity
indicator and silica gel ) meeting one of below criteria,
please bake ( dry ) before use.
• When the storage conditions specified in 1) are
exceeded.
• When humidity indicator is in Ⅲ or Ⅳ status according
to judgement standard.
Please check humidity indicator color and decide if
baking is necessary or not.
●: indicate brown, ○: Other than brown ( blueish color )
5%
10%
60%
Bake treatment
necessity judgment
Ⅰ
●
●
●
No need to bake
Ⅱ
○
●
●
No need to bake
Ⅲ
○
○
●
Need to bake
Ⅳ
○
○
○
Need to bake
Spot
5%
10%
● Silicon
When a source of silicone substances ( silicone rubber,
silicone oil,silicone coating materials and silicone filling
materials etc. ) is used around the relay, the silicone gas
( low molecular siloxane etc. ) may be produced
This silicone gas may penetrate into the inside of the
relay. When the relay is kept and used in this condition,
silicone compound may adhere to the relay contacts
which may cause the contact failure.
Do not use any sources of silicone gas around the relay
( Including plastic seal types ).
● NOx Generation
When relay is used in an atmosphere high in humidity
to switch a load which easily produces an arc, the NOx
created by the arc and the water absorbed from outside
the relay combine to produce nitric acid.
This corrodes the internal metal parts and adversely
affects operation.
Avoid use at an ambient humidity of 85 % RH or higher
( at 20 ℃ ).
If use at high humidity is unavoidable, please contact our
sales representative.
60%
Humidity indicator card
<Baking ( Drying ) conditions>
• With reel : 45 ℃, 96 hours or more.
• Without reel ( including relay only ): 60 ℃, 35 hours
or more.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 13 ー
Panasonic Industry Co., Ltd. 2022
ASCTB414E 202210
GUIDELINES FOR SIGNAL RELAYS USAGE
OTHERS
■ Cleaning
• Although the environmentally sealed type relay (plastic
sealed type,etc. ) can be cleaned, avoid immersing
the relay into cold liquid ( such as cleaning solvent )
immediately after soldering.
Doing so may deteriorate the sealing performance.
• Surface-mount terminal type relay is sealed type and it
can be cleaned by immersion.
Use pure water or alcohol-based cleaning solvent.
• Cleaning with the boiling method is recommended ( The
temperature of cleaning liquid should be 40℃ or lower ).
Avoid ultrasonic cleaning on relays.
Use of ultrasonic cleaning may cause breaks in the coil
or slight sticking of the contacts due to the ultrasonic
energy.
Please refer to "the latest product specifications"
when designing your product.
•Requests to customers:
https://industrial.panasonic.com/ac/e/salespolicies/
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 14 ー
Panasonic Industry Co., Ltd. 2022
ASCTB414E 202210
■ Global Sales Network Information: industrial.panasonic.com/ac/e/salesnetwork
Electromechanical Control Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industrial.panasonic.com/ac/e/
©Panasonic Industry Co., Ltd. 2022
Specifications are subject to change without notice.
モヴヤヵャヘユチチチビパビビヒパ