Small size controlled 3.5 A
inrush current possible
GQ RELAYS
TH types
FEATURES
TYPICAL APPLICATIONS
1. Small size controlled 3.5 A inrush
current possible
2. 2.4 coil voltage type newly available
DC battery operation
3. Flat compact size
10.6 (L) × 7.2 (W) × 5.2 (H) mm
.417 (L) × .283 (W) × .205 (H) inch
1. Thermostat (HVAC temperature
controller)
2. Others, High-capacity control etc.
RoHS compliant
ORDERING INFORMATION
AGQ 2
T
Contact arrangement
2: 2 Form C
Operating function
0: Single side stable
1: 1 coil latching
Type of operation
T: Power type (B.B.M.)
Terminal shape
Nil: Standard PC board terminal
A: Surface-mount terminal A type
S: Surface-mount terminal S type
Nominal coil voltage (DC)
1H: 1.5V 2H: 2.4V 03: 3V 4H: 4.5V 06: 6V
09: 9V 12: 12V 24: 24V
Packing style
Nil: Tube packing
X: Tape and reel packing (picked from 1/2/3/4 pin side)
Z: Tape and reel packing (picked from 5/6/7/8 pin side)
TYPES
1. Standard PC board terminal
Nominal coil voltage
1.5 V DC
2.4 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
Single side stable
Part No.
AGQ20T1H
AGQ20T2H
AGQ20T03
AGQ20T4H
AGQ20T06
AGQ20T09
AGQ20T12
AGQ20T24
1 coil latching
Part No.
AGQ21T1H
AGQ21T2H
AGQ21T03
AGQ21T4H
AGQ21T06
AGQ21T09
AGQ21T12
AGQ21T24
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
–1–
ASCTB375E 201607-T
GQ (AGQ)
2. Surface-mount terminal
1) Tube packing
Single side stable
Part No.
AGQ20T1H
AGQ20T2H
AGQ20T03
AGQ20T4H
AGQ20T06
AGQ20T09
AGQ20T12
AGQ20T24
Nominal coil voltage
1.5 V DC
2.4 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
1 coil latching
Part No.
AGQ21T1H
AGQ21T2H
AGQ21T03
AGQ21T4H
AGQ21T06
AGQ21T09
AGQ21T12
AGQ21T24
: For each surface-mounted terminal identification, input the following letter. A type: A, S type: S
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
2) Tape and reel packing
Single side stable
Part No.
AGQ20T1HZ
AGQ20T2HZ
AGQ20T03Z
AGQ20T4HZ
AGQ20T06Z
AGQ20T09Z
AGQ20T12Z
AGQ20T24Z
Nominal coil voltage
1.5 V DC
2.4 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
1 coil latching
Part No.
AGQ21T1HZ
AGQ21T2HZ
AGQ21T03Z
AGQ21T4HZ
AGQ21T06Z
AGQ21T09Z
AGQ21T12Z
AGQ21T24Z
: For each surface-mounted terminal identification, input the following letter. A type: A, S type: S
Standard packing: Tape and reel: 900 pcs.; Case: 1,800 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
2. Please inquire if you require a relay, between 1.5 and 24 V DC, with a voltage not listed.
RATING
1. Coil data
1) Single side stable type
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
1.5 V DC
93.8 mA
16
2.4 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
58.5 mA
46.7 mA
31 mA
23.3 mA
15.5 mA
11.7 mA
41 Ω
64.2 Ω
145 Ω
257 Ω
579 Ω
1,028 Ω
Nominal coil
voltage
24
Pick-up voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage*
(Initial)
V DC
9.6 mA
2,504
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
140 mW
150%V of
nominal voltage
230 mW
120%V of
nominal voltage
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
100 mW
150%V of
nominal voltage
Ω
Ω
2) 1 coil latching type
1.5 V DC
Nominal operating
current
[±10%] (at 20°C 68°F)
66.7 mA
2.4 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
41.7 mA
33.3 mA
22.2 mA
16.7 mA
11.1 mA
8.3 mA
5.0 mA
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Reset voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Coil resistance
[±10%] (at 20°C 68°F)
22.5 Ω
57.6 Ω
90 Ω
202.5 Ω
360 Ω
810 Ω
1,440 Ω
4,800 Ω
120 mW
*Pulse drive (JIS C 5442-1996)
–2–
ASCTB375E 201607-T
GQ (AGQ)
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive)
Max. switching power (resistive)
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Specifications
2 Form C
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgNi + Au plating
2 A 30 V DC, 1 A 30 V DC, 0.3 A 125 V AC
60 W (DC), 30 W (DC), 37.5 V A (AC)
110 V DC, 125 V AC
2 A (AC, DC)
10μA 10 mV DC
Single side stable
1 coil latching
Nominal operating
power
140mW (1.5 to 12 V DC), 230mW (24 V DC)
100mW (1.5 to 12 V DC), 120mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measured portion is the same as the case of dielectric voltage
Insulation resistance (Initial)
Electrical
characteristics
Breakdown voltage
(Initial)
Between open contacts
Between contact and coil
Between contact sets
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial)
Between open contacts
Between contact and coil
1,500 V (10×160μs) (FCC Part 68)
2,500 V (2×10μs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 750 m/s2 (half -sine shock pulse: 6 ms; detection time: 10μs.)
Min. 1,000 m/s2 (half -sine shock pulse: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 5.0 mm
Min. 5 × 107 (at 180 cpm)
Min. 1 × 105 (1A 30V DC resistive)
Min. 1 × 105 (3.5A inrush (250ms)/1A 30V AC (cosφ =0.4)) (ON/OFF=1s/9s)
Ambient temperature:
(Single side stable, 1 coil latching type) –40°C to +85°C –40°F to +185°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 1.0 g .035 oz
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F) (Initial)
Release time [Reset time] (at 20°C 68°F) (Initial)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Shock resistance
Mechanical
characteristics
Expected life
Conditions
Electrical
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Unit weight
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA
1. Electrical life (1 × 105 operation is possible)
Tested sample: AGQ21TA03, 6 pcs.
Switching frequency: ON:OFF = 1s:9s
Ambient temperature: 25°C 77°F
Circuit
COM1
Condition: 30V AC
Inrush current: 3.5A (effective value),
Inrush time 250ms
steady current: 1.0A (effective value),
(Inductive load cosφ = 0.4)
Inrush current wave form VS time
NO1
Detection
Circuit
60Hz
–
24V
+
Contact Weld
Min 0.5s
Miss Contact
after 0.2s
G
6
Contact Current, A
AC30V
4
2
0
-2
-4
-6
Time (ms), Interval (100ms)
*Precaution
When using at 3.5A, connection of NO
(pin #5 and #8) and COM (pin #4 and #9)
in the circuit is required.
Pin layout and schematic (Bottom View)
1 coil latching
1
2
3
4
8
7
6
5
Load
–3–
ASCTB375E 201607-T
GQ (AGQ)
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. PC board terminal
External dimensions
CAD Data
10.60±0.3
.417±.012
PC board pattern
5.20±0.2
.205±.008
3.20
.126
0.40±0.1
.016±.004
3.20±0.15
.126±.006
0.20±0.1
.008±.004
5.08±0.15
.200±.006
2.20±0.15
.087±.006 3.50±0.3
2.20±0.15 .138±.012
.087±.006
Schematic (Bottom view)
Single side stable
High sensitivity
single side stable
2.20
.087
7.20±0.3
.283±.012
2.20
.087
5.08
.200
1
2 3 4
8
7 6 5
1 coil latching
1
2 3 4
8
7 6 5
0.85 dia.
.033 dia.
Tolerance: ±0.1 ±.004
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
2. Surface-mount terminal
CAD Data
Suggested mounting pad (Tolerance: ±0.1 ±.004)
Single side stable/1 coil latching/High sensitivity single side stable
External dimensions
Single side stable/1 coil latching/High sensitivity single side stable
Type
Max. 5.40
.213
7.20±0.3
.283±.012
10.60±0.3
.417±.012
A type
0.40±0.1
.016±.004
3.20±0.15
.126±.006
Max. 5.40
.213
2.20±0.15
.087±.006
2.20±0.15
.087±.006
0.20±0.1
.008±.004
2.66 6.74
.105 .265
5.08±0.15
.200±.006
8.40±0.3
.331±.012
0.80
.031
7.20±0.3
.283±.012
10.60±0.3
.417±.012
2.20
.087
2.20
.087
3.20
.126
S type
0.40±0.1
.016±.004
3.20±0.15
.126±.006
2.20
.087
2.20
.087
3.20
.126
0.20±0.1
.008±.004
5.08±0.15
.200±.006
2.20±0.15
.087±.006
2.20±0.15
.087±.006
2.06
.081
6.14
.242
0.80
.031
7.20±0.3
.283±.012
Schematic (Top view)
Single side stable
High sensitivity single side stable
8
7 6 5
1
2 3 4
1 coil latcing
8
7 6 5
1
2 3 4
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
–4–
ASCTB375E 201607-T
GQ (AGQ)
NOTES
1. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
(S type)
(1)-2 Tape dimensions
Relay polarity bar
(Z type)
1.50 +0.1
0 dia.
.059 +.003
.0 dia.
2.0
.079
Orientation (indicates PIN No.1) stripe
4.0 2.00 dia.
.157 .079 dia.
1.75
.069
11.5
.453
Max. 6.55
.256
0.40
.016
24.0±0.3
.945±.012
11.1
.437
GQ relays
12.0
.472
7.8
.307
Tape coming out direction
Stopper (green)
Stopper (red)
General tolerance ±0.1 mm .004 inch
(2) Dimensions of plastic peel
Orientation (indicates PIN No.1) stripe
mm inch
C
B
Stopper (red)
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
80±1 dia.
3.150±.039 dia.
mm inch
Relay polarity bar
(Z type)
1.5+0.1
0 dia.
.059+.003
dia.
.0
2.0
.079
330±2 dia.
12.992±.079 dia.
4.0 2.0 dia.
.157 .079 dia.
1.75
.069
Max. 6.55
.256
0.40
.016
11.5
.453 24.0±0.3
.945±.012
11.1
.437
GQ relays
A
21±0.8 dia.
.827±.031 dia.
2.0±0.5
.079±.020
Stopper (green)
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A :
9.8 N {1 kgf} or less
Chucking pressure in the direction B :
9.8 N {1 kgf} or less
Chucking pressure in the direction C :
9.8 N {1 kgf} or less
12.0
.472
13±0.2 dia.
.512±.008 dia.
9.0
.354
Please chuck the
portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be also
avoided.
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
Tape coming out direction
General tolerance ±0.1 mm .004 inch
–5–
ASCTB375E 201607-T