AH1564619

AH1564619

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    SWITCH SNAP ACT SPDT 100MA 125V

  • 详情介绍
  • 数据手册
  • 价格&库存
AH1564619 数据手册
AH1 (FJ) SWITCHES Ultra-miniature Size Switches with High Precision FEATURES • Compact size, light weight and high precision • Switches that can be used with M2 general-purpose screws • Integrally molded terminals that discourage inflow of solder flux provide and also switch body has stand-off • Lineup also includes low-level circuit types (Au-clad contacts) optimized for low-voltage current loading • Self-standing terminal easily mounted on PC boards • Protection grade: IP40 Right angle terminal TYPICAL APPLICATIONS • Computer mouse • Charger unit for portable terminal • Electric pot • Automobiles (Detection of key position), etc. Left angle terminal RoHS compliant ORDERING INFORMATION AH 1 Mounting hole and terminal 4: Self-standing PC board terminal 5: Straight PC board terminal 6: Solder terminal 7: Right angle terminal 8: Left angle terminal Operation load 0: Pin plunger 4: Simulated roller lever ■ Mounting hole M2 mm type (with stand off) Available Applicable current range 1mA 0.1A 1A 3A Operating Force OF (max.) 0.74N Safety standard 9: UL/C-UL 2: Hinge lever PRODUCT TYPES TABLE Contact specification Contact Nil: AgNi alloy contact 61: AgNi alloy + Au-clad contact Actuator 5th digit of part No. Actuator 6 8 1.47N 0.74N Pin plunger 0.49N 0.25N Hinge lever Simulated roller lever 0.54N 0.26N 1.47N COMBINATION WITH OPERATING FORCE (OF) AND APPLICABLE CURRENT RANGE (reference) 3A AgNi alloy contact Standard type (AgNi alloy contact) 1A OF0.74N OF1.47N 100mA Low-level circuit type (AgNi alloy + Au-clad contact) Au-clad contact 1mA 0 DC 5V AC 5V 15V 15V 30V 125V Note) OF: Value of pin plunger –1– AECTB15E 201510-T AH1 (FJ) Miniature Switches DATA CONTACT FORM Range of low-level current and voltage (Low-level circuit type) (reference) Current (mA) 500 100 50 NC NO COM 10 5 2 1 4 8 12 16 20 24 DC voltage (V) PRODUCT TYPES Standard type; Body: black, Cap: black, Plunger: white Low-level circuit type; Body: black, Cap: black, Plunger: red ■ Self-standing PC board terminal Actuators Pin plunger Hinge lever Simulated roller lever Operating Force OF, Max. 0.74 N 1.47 N 0.25 N 0.49 N 0.26 N 0.54 N Standard type (AgNi alloy contact) Contact form: SPDT AH14809 AH14609 AH14829 AH14629 AH14849 AH14649 Low-level circuit type (AgNi alloy + Au-clad contact) Contact form: SPDT AH1480619 AH1460619 AH1482619 AH1462619 AH1484619 AH1464619 Standard type (AgNi alloy contact) Contact form: SPDT AH15809 AH15609 AH15829 AH15629 AH15849 AH15649 Low-level circuit type (AgNi alloy + Au-clad contact) Contact form: SPDT AH1580619 AH1560619 AH1582619 AH1562619 AH1584619 AH1564619 Standard type (AgNi alloy contact) Contact form: SPDT AH16809 AH16609 AH16829 AH16629 AH16849 AH16649 Low-level circuit type (AgNi alloy + Au-clad contact) Contact form: SPDT AH1680619 AH1660619 AH1682619 AH1662619 AH1684619 AH1664619 Standard type (AgNi alloy contact) Contact form: SPDT AH17809 AH17609 AH17829 AH17629 AH17849 AH17649 Low-level circuit type (AgNi alloy + Au-clad contact) Contact form: SPDT AH1780619 AH1760619 AH1782619 AH1762619 AH1784619 AH1764619 ■ Straight PC board terminal Actuators Pin plunger Hinge lever Simulated roller lever Operating Force OF, Max. 0.74 N 1.47 N 0.25 N 0.49 N 0.26 N 0.54 N ■ Solder terminal Actuators Pin plunger Hinge lever Simulated roller lever Operating Force OF, Max. 0.74 N 1.47 N 0.25 N 0.49 N 0.26 N 0.54 N ■ PC board right angle terminal Actuators Pin plunger Hinge lever Simulated roller lever Operating Force OF, Max. 0.74 N 1.47 N 0.25 N 0.49 N 0.26 N 0.54 N –2– AECTB15E 201510-T AH1 (FJ) Miniature Switches ■ PC board left angle terminal Standard type (AgNi alloy contact) Contact form: SPDT AH18809 AH18609 AH18829 AH18629 AH18849 AH18649 Operating Force OF, Max. Actuators 0.74 N 1.47 N 0.25 N 0.49 N 0.26 N 0.54 N Pin plunger Hinge lever Simulated roller lever Low-level circuit type (AgNi alloy + Au-clad contact) Contact form: SPDT AH1880619 AH1860619 AH1882619 AH1862619 AH1884619 AH1864619 Notes: 1. The appearance of right and left angle types are as below. Right angle Left angle 2. Standard packing: 50 pcs./tube. SPECIFICATIONS ■ Contact rating Standard type (AgNi alloy contact) Plunger color: White Standard rating Minimum rating OF 0.74N type 1A 125V AC, 1A 30V DC — OF 1.47N type 3A 125V AC, 2A 30V DC — 0.1A 125V AC, 0.1A 30V DC 5mA 6V DC, 2mA 12V DC, 1mA 24V DC Low-level circuit type (AgNi alloy + Au-clad contact) Plunger color: Red ■ Characteristics Item Expected life Mechanical life (OT: Specified value) Electrica (OT: Max.) Insulation resistance Between non-continuous terminals Dielectric Between each terminal and other exposed strength metal parts Between each terminal and ground Standard type Low-level circuit type (AgNi alloy contact) (AgNi alloy + Au-clad contact) OF 0.74 N type: Min. 106 (at 60 cpm) OF 1.47 N type: Min. 5 × 105 (at 60 cpm) Min. 3 × 104 Min. 105 (at 20 cpm) (at rated load) (at 20 cpm) (at rated load) Min. 100 MΩ (at 500V DC) 600 Vrms for 1 min. 1,500 Vrms for 1 min. 1,500 Vrms for 1 min. Max. 30 mΩ Max. 100 mΩ (by voltage drop, 1A 6 to 8V DC) (by voltage drop, 0.1A 6 to 8V DC) 10 to 55 Hz at single amplitude of 0.75mm (Contact opening: Max. 1 msec.) Min. 294 m/s2 (Contact opening: Max. 1 msec.) 1 to 500 mm/sec. 120 cpm –25 to +85°C (no freezing and condensing) Approx. 0.5g IP40 Contact resistance (Initial) Vibration resistance (Pin pluger type) Shock resistance (Pin plunger type) Allowable operating speed (No load) Max. operating cycle rate (No load) Ambient temperature Unit weight Protection grade Notes: 1. Test conditions and judgement are in accordance with NECA C 4505. 2. OF: Value of pin plunger type ■ Operating characteristics 1) Pin plunger 3th digit of Part No. Operating Force OF, Max. Release Force RF, Min. 6 1.47 N 0.20 N 8 0.74 N 0.098 N 3th digit of Part No. Operating Force OF, Max. Release Force RF, Min. 6 0.49 N 0.049 N Pretravel PT, Max. Movement Differential MD, Max. Overtravel OT, Min. Operating Position OP 0.5 mm 0.12 mm 0.25mm 7±0.3 mm (Distance from stand-off) 5.5±0.2 mm (Distance from mounting hole) 7±0.3 mm (Distance from stand-off) 5.5±0.2 mm (Distance from mounting hole) Pretravel PT, Max. Movement Differential MD, Max. Overtravel OT, Min. Operating Position OP 0.55 mm 8.3±1.2 mm (Distance from stand-off) 6.8±1.0 mm (Distance from mounting hole) 8.3±1.2 mm (Distance from stand-off) 6.8±1.0 mm (Distance from mounting hole) 2) Hinge lever 2.1 mm 8 0.25 N 0.025 N –3– 0.5 mm AECTB15E 201510-T AH1 (FJ) Miniature Switches 3) Simulated roller lever 3th digit of Part No. Operating Force OF, Max. Release Force RF, Min. 6 0.54 N 0.039 N Pretravel PT, Max. Movement Differential MD, Max. 2.1 mm 8 0.26 N 0.5 mm Overtravel OT, Min. Operating Position OP 0.5 mm 11.0±1.2 mm (Distance from stand-off) 9.5±1.0 mm (Distance from mounting hole) 11.0±1.2 mm (Distance from stand-off) 9.5±1.0 mm (Distance from mounting hole) 0.020 N DIMENSIONS (Unit: mm) General tolerance: ±0.25 The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ ■ Self-standing PC board terminal Pin plunger External dimensions CAD Data 5.4±0.3 (PT) 0.5 max. 1 PC board pattern 2.8 5.08±0.1 (OP) 5.5±0.2 5±0.15 2 +0.12 0 3-1.2±0.05 dia. 5.08±0.1 (OP) 7±0.3 1.6 1.5±0.1 1.1±0.12 1.1±0.12 2 +0.12 0 dia. 2.2 +0.12 0 6-C0.3 6.5±0.1 ±0.15 t=0.4 1.25±0.12 0.9 ±0.15 5.08 4 5.08 6±0.15 12.8±0.15 Pretravel PT, Max. Movement Differential MD, Max. Overtravel OT, Min. Distance from mounting hole Operating Position OP Distance from stand-off 0.5 mm 0.12 mm 0.25 mm 5.5±0.2 mm 7±0.3 mm Hinge lever External dimensions CAD Data PC board pattern (PT) 2.1 max. 4.4 5.08±0.1 3-1.2±0.05 dia. 5.08±0.1 (OP) 6.8±1.0 (OP) 8.3±1.2 5±0.15 2 +0.12 0 1.6 1.5±0.1 2 +0.12 0 dia. 1.1±0.12 1.5±0.12 2.2 +0.12 0 6-C0.3 ±0.1 6.5 5.08±0.15 4 t=0.4 1.25±0.12 0.9 5.08±0.15 6±0.15 12.8±0.15 Pretravel PT, Max. Movement Differential MD, Max. Overtravel OT, Min. Distance from mounting hole Operating Position OP Distance from stand-off 2.1 mm 0.5 mm 0.55 mm 6.8±1.0 mm 8.3±1.2 mm Simulated roller lever External dimensions CAD Data (PT) 2.1 max. 3.3±0.4 5.4±0.3 PC board pattern 5.08±0.1 R2.5 3-1.2±0.05 dia. 5.08±0.1 11±1.2 (OP) 9.5±1.0 5±0.15 2 +0.12 0 1.6 1.5±0.1 2 +0.12 0 dia. 1.1±0.12 1.5±0.12 2.2 +0.12 0 6.5±0.1 5.08±0.15 5.08±0.15 6-C0.3 t=0.4 1.25±0.12 0.9 6±0.15 12.8±0.15 –4– 4 Pretravel PT, Max. Movement Differential MD, Max. Overtravel OT, Min. Distance from mounting hole Operating Position OP Distance from stand-off 2.1 mm 0.5 mm 0.5 mm 9.5±1.0 mm 11.0±1.2 mm AECTB15E 201510-T AH1 (FJ) Miniature Switches ■ Solder terminal Pin plunger CAD Data 2.0+0.12 0 1.5±0.1 5.0 2.0 2.2+0.12 0 2+0.12 dia. 0 5.08±0.15 0.5 t=0.4 2.2 6.5±0.1 1.2 6-C0.3 5.08±0.15 12.8±0.15 (Dimensions other that drawn above is same as self-standing PC board terminal.) ■ PC board right/left angle terminal Pin plunger External dimensions CAD Data PC board pattern 3-1.2±0.05 dia. C0.3 Right angle 2.93 (Position of pin plunger) 5.08±0.1 10.16±0.15 Left angle Pin plunger (PT) 0.5 max. 5.4±0.3 1 2.8 (OP) 5.5±0.2 5±0.15 2+0.12 0 1.5±0.1 1.6 2+0.12 dia. 0 2.2+0.12 0 6.5±0.1 5.08±0.15 6±0.15 3.1 (3.3) t=0.4 0.9 5.08±0.15 Left angle Right angle 12.8±0.15 Note: As for other actuator types, dimensions are the same as those of corresponding self-standing PC board terminal. CAUTIONS FOR USE ■ Fastening of the switch body 1) Use M2 screws to attach switches with Max. 0.098 N·m torque. Use of screw washers or adhesive lock is recommended. 2) When the operation object is in the free position, force should not be applied directly to the actuator or to the pin plunger. Also force should be applied to the pin plunger from vertical direction to the switch. 3) In setting the movement after operation, the overtravel “OT”should be set from 70% to 100%. Setting the movement less than 70% may cause degrading of the electrical mechanical performance. ■ Selection of switch Please make your selection so that there will be no problems even if the operating characteristics vary up to ±20% from the standard values. ■ Soldering operation Perform soldering in less than 3 seconds with maximum 350°C iron. Care should be taken not to apply force to the terminals during soldering. We recommend a soldering iron with temperature adjustment in order to prevent poor quality soldering. Please consult us if you intend to use a soldering iron of 60 W or higher. –5– ■ When switching low-level current and voltage, low-level circuit type (Auclad contact) is recommended. ■ Environment Locations where corrosive gases having a bad influence on contacts are present, and locations where there is an excessive amount of siliceous or other abrasive dust should be avoided. AECTB15E 201510-T Technical Terminology & Cautions for Use (Snap-action, Detection and Interlock Switches) TECHNICAL TERMINOLOGY ■ Snap-action switches A compact switch equipped with an enclosed micro-gap snapaction contact mechanism that makes a specified motion with a specified force to open/close a circuit, and an actuator outside the enclosure (hereinafter referred to as the switch) ■ Actuator A part of the switch that transmits the received external force to an internal spring mechanism to move the movable contact so that the switch can be opened and closed ■ Actuator stopper A part of the switch to limit the actuator movement in the switch operation direction ■ Rated values Values indicating the characteristics and performance guarantee standards of the snap-action switches. The rated current and rated voltage, for instance, assume specific conditions (type of load, current, voltage, frequency, etc.). ■ Mechanical life The service life when operated at a preset operating frequency without passing electricity through the contacts. (The life test is performed at a switching frequency of 60 times/minute and operating speed of 100 mm/second at the regular cam.) ■ Electrical life The service life when the rated load is connected to the contact and switching operations are performed. (The life test is performed at a switching frequency of 20 times/minute and operating speed of 100 mm/second at the regular cam.) ■ Contact form This refers to the components determining the type of application which make up the electrical input/output circuits in the contact. NC SPDT COM SPST-NC SPST-NO NO NC COM COM NO Terminal symbols COM: Common terminal NC: Normally closed terminal NO: Normally open terminal ■ Insulation resistance Resistance between non-continuous terminals, each terminal and other exposed metal parts and between each terminal and ground. ■ Dielectric Threshold limit value that a high voltage can be applied to a predetermined measuring location for one minute without causing damage to the insulation. ■ Contact resistance This indicates the electrical resistance at the contact part. Generally, this resistance includes the conductor resistance of the spring and terminal portions. ■ Vibration resistance Malfunction vibration ... Vibration range where a closed contact does not open for longer than a specified time due to vibrations during use of the snap-action switches. ■ Shock resistance Shock durability ... Shock range where the mechanical shocks received during snap-action switches transport and installation do not damage the parts or harm the operating characteristics. Malfunction shock ... Shock range where a closed contact does not open for longer than a specified time due to shocks during use of the snap-action switches. –1– AECTB36E 201510-T Technical Terminology & Cautions for Use OPERATING CHARACTERISTIC ■ Definition of operating characteristic The main terminological illustrations and meanings which are used with snapaction switches are as follows. Classification RF OF PT TF Force TT FP OT Symbol Unit Varying display method Operating Force OF N Max. Release Force RF N Min. Totaltravel Force TF N Pretravel PT mm, degree Max. Overtravel OT mm, degree Min. Movement Differential MD mm, degree Max. Totaltravel TT Free Position FP Operating Position OP mm, degree Release Position RP mm, degree The position of the actuator when the traveling contact snaps back from operating position to its original position. Total travel Position TTP mm, degree The stopping position of the actuator after total travel. Terminology MD OP RP TTP Movement Center of mounting holes Position mm, degree mm, degree ± Starting current The force required to cause contact snap-action. It is expressed terms of force applied to the the actuator. The force to be applied to the the actuator at the moment contact snaps back from operated position to total travel position. Force applied to an actuator required to move from an operating position to a total travel position Distance or agree of the actuator movement from free position to operating position. The distance or degree which the actuator is permitted to travel after actuation without any damage to the switching mechanism. The distance or degree from operating position to release position of the actuator. The migration length or the move angle from the free position to total travel position of actuator Position of the actuator when no force is applied to. The position of the actuator when the traveling contacts snaps with the fixed contact. TECHNICAL NOTES ON MECHANICAL CHARACTERISTICS OF RF FP Contact force The figure at right shows a typical example of activation and contact forces varying with stroke. In the vicinity of the OP and RP, the contact force is diminished, causing chatter and contact bounce immediately before or after reversal. For this reason, use the switch while giving due consideration to this. This also causes the snap action switch to be sensitive to vibration or shock. Operating force ■ Actuation Force and Stroke Adequate stroke setting is the key to high reliability. It is also important that adequate contact force be ’maintained to ensure high reliability. For a normally closed (NC) circuit, the driving mechanism should be set so that the actuator is normally in the free position. For a normally open (NO) circuit, the actuator should be pressed to 70% to 100% of the specified stroke to absorb possible errors. If the stroke is set too close to the operating point (OP), this may cause unstable contact, and in the worst case may cause actuator damage due to inertia of the drive mechanism. It is advisable that the stroke be adjusted with the mounting plate or driving mechanism. RP PT TTP OP MD ■ Changes in Operating Characteristics Exercise design care so that malfunctions will not occur if the operating characteristics vary by as much as 20% from, rated values. In the OF max. 0.98N specification for FS snap-action switches, the allowable max. is 0.98 N × (100%+20%) = 1.18 N In the RF min. 0.15 N min. specification the allowable min. 0.15 N × (100%–20%) = 0.12 N ■ Mechanical Conditions for Type Selection Actuator type should be selected according to activation method, activation speed, activation rate, and activation frequency. 1) An extremely slow activation speed may cause unstable contact transfer, possibly resulting in contact failures or contact fusion. 2) An extremely high activation speed may cause damage to contacts or contact response failure. Stroke ■ Driving Mechanism Use of a driving mechanism which will cause physical impact to the actuator should be avoided. OT NC On FP On reversal On reversal On OTP NO Stroke Bad –2– Good AECTB36E 201510-T Technical Terminology & Cautions for Use TECHNICAL NOTES ON ELECTRICAL CHARACTERISTICS 1) The snap-action switch is designed for AC operations. While it has small contact gaps and no arc absorber, it may be used for low-capacity DC operations. Please refer to the rating of each products 2) For applications with very small switching voltage or current, choose the low-level load type (Au contact). Small current and voltage application range (Au contact) Current (mA) 500 100 50 10 5 2 1 4 8 12 16 20 24 DC voltage (VDC) 3) When selecting a contact type of a snap-action switch to be used for low-level load switching, the following should be noted. Silver contacts’ surfaces are prone to be oxidized and form a sulfide film. The switch operates with no problems at the beginning of use. However, as the contact surfaces develop films with time, the film may not be broken by the switching operation, causing a conduction failure. Therefore, please choose the Au contact type for switching a load of 0.1 A or below. 4) Application to Electronic Circuits • The snap-action switch contacts can sustain bounce or chatter when closed. Bounce or chatter can cause noise or pulse count errors when the snap action switch is used in electronic circuits. • If contact bounce or chatter poses problems in the vicinity of the OP and RP, use a suitable absorption network, such as a C/ R network. 5) Check the surge current, normal current and surge duration. 6) Contact resistance given in performance specifications is measured with a voltage drop method using 6 to 8 V DC, 1 A (except for low-level load type). Contact resistance across COM and NC terminals is measured in the free position, while contact resistance across COM and NO terminals is measured in the total travel position. 7) Ratings are measured under the following conditions: Inductive load: Power factor 0.6 to 0.7 Time constant: 7 ms or less (DC) 8) To prevent contact welding failure, be sure to use a serial resistance for each capacitive load. 9) If snap-action switch operation is synchronized with the AC supply phase, this may cause: shortened electrical life, contact fusion failure, contact transfer, or other reliability problems. CAUTIONS IN A CIRCUIT 1) Contact protection is recommended when snap-action switches are used in an inductive load circuit. Circuit diagram Contact for snap-action switch r c R Contact for snap-action switch r c R Contact for snap-action switch diode Cautions for use (1) r = more than 10 Ω (2) In an AC circuit Impedance of R is to be slightly smaller than impedance of r and c. Can be used for both AC and DC. Impedance of r is nearly equal to impedance of R. C: 0.1 μF Wrong Lamp load PL Solenoid load Right Lamp load PL Solenoid load Load connected to same pole Example of wrong power supply connection (connection to different poles of power supply) This may lead to mixed DC and AC. (1) For DC circuits only. R Contact for snap-action switch 2) Do not connect the contacts on individual switches to different type or different poles of the power supply. Examples of power supply connections (connection to different poles) Can be used for both AC and DC. Wrong Load L AC DC Load ZNR Varistor L R 3) Avoid circuits which apply voltage between contacts. (This may lead to mixed deposition.) Wrong L 200V 100V –3– AECTB36E 201510-T Technical Terminology & Cautions for Use MOUNTING STATE AND ENVIRONMENT ■ Checking the insulation distance After mounting and wiring, check the insulation distance between terminals and the ground. If the insulation distance is inadequate, mount insulating material between as required. ■ Fastening the snap-action switch body See the Section “CAUTIONS FOR USE” for the individual switch. ■ Position adjustment with effector 1) The effector should be positioned so that direct force is not applied to the plunger or actuator in its free position. The operating force to the plunger should only be applied in a perpendicular direction. 2) Note that the use of the switch as a stopper may cause an operational problem. ■ Switch installation position • Basically, the switch should be installed so that the object to press the switch’s plunger or lever can press it down to 70 to 100% of OT of the switch. When determining the position, the tolerance of OP (Operating Position) and other factors should be taken into account. The following describes the case where the strictest tolerance conditions are adopted. • Example: Hinge lever type FS switch Reference values: OP = 8.8±0.8mm PT = max. 2.8mm OT = min. 1.2mm FP OP TTP PT OT (1) When the switch is not pressed The object to press the lever should not be in contact with the lever. For this purpose, the object should be at a distance from the switch father than the maximum FP (Free Position) value. FP max = OP max + PT max = 9.6 + 2.8 = 12.4 mm max The object should be at a distance of 12.4 mm or more from the mounting hole. (2) Depressed position The plunger/lever should be pressed down to 70% or more of OT (Over Travel). Therefore, the depressed position should be calculated based on the minimum value of OP (Operating Position) and the 70 and 100% of the OT value. OP min - 70% of OT = 8.0 - 0.84 = 7.16 mm OP min - 100% of OT = 8.0 - 1.2 = 6.80 mm The plunger/lever should be pressed down to the position of 6.80 to 7.16 mm from the mounting hole. ■ Soldering precautions For manual soldering, lay the terminals flat (horizontal with the ground) and quickly perform the soldering operation using a soldering iron with the appropriate heat capacity and the proper amount of solder. Take care that the flux does not flow into the switch interior by using a ventilation fan to discharge flux gas and to prevent contact of the switch body with the soldering iron tip. Be careful not to apply force to the lead wires or the terminal portions immediately after soldering. The temperature setting and time conditions vary depending on the product. See the section “CAUTIONS FOR USE” for each product. Wrong Soldering iron tip Correct ■ Avoid using in a silicon atmosphere Avoid using organic silicon rubber, adhesives, sealing compounds, oil, grease, and wires in a silicon atmosphere. ■ Please consult us when using under the following conditions*: 1) Environments where hydrogen sulfide or other corrosive gases are present. 2) Environments where gasoline, thinner or other flammable, explosive gases are present. 3) Dusty environments (for non-seal type snap action switches). 4) The perpendicular operating speed exceeds the allowable operating speed. 5) Switching between different poles. 6) Use in environments not in the prescribed temperature or humidity range. ■ Storage precautions To prevent discoloration due to sulfurization of the terminals (silver- plated), store the switches in a polyethylene bag or other suitable airtight container. –4– AECTB36E 201510-T Technical Terminology & Cautions for Use ■ Usage, storage, and transport conditions During usage, storage, or transportation, avoid locations subject to direct sunlight and maintain normal temperature, humidity, and pressure conditions. The allowable specifications for environments suitable for usage, storage, and transportation are given below. 1) Temperature: The allowable temperature range differs for each switch, so refer to the switch’s individual specifications. In addition, when transporting or storing switches while they are tube packaged, there are cases when the temperature may differ from the allowable range. In this situation, be sure to consult the individual specifications. 2) Humidity: 5 to 85% R.H. 3) Pressure: 86 to 106 kPa The humidity range varies with the temperature. Use within the range indicated in the graph below. Humidity, %R.H. 85 Tolerance range (Avoid freezing when (Avoid used at temperatures condensation when lower than 0°C 32°F) used at temperatures higher than 0°C 32°F) 5 –40 –40 0 +32 Temperature, °C °F +85 +185 ■ We reserve the right to modify without notice the materials, internal components, and other parts to improve product quality. ■ Handling precautions When handling the switches, be careful not to drop them on the floor since this may damage them. * Select contact sulfurization (clipping) prevention products (FS and Au-clad double layer contacts) for use with extremely small loads or an environment-resistant Turquoise switch. ■ Others 1) Failure modes of switches include short-circuiting, opencircuiting and temperature rises. If this switch is to be used in equipment where safety is a prime consideration, examine the possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. In terms of the systems involved, make provision for redundancy in the design and take steps to achieve safety design. 2) The ambient operating temperature (and humidity) range quoted is the range in which the switch can be operated on a continuous basis: it does not mean that using the switch within the rating guarantees the durability performance and environment withstanding performance of the switch. For details on the performance guarantee, check the specifications of each product concerned. (The allowable temperature depends on the switch.) • Condensation will occur inside the switch if there is a sudden change in ambient temperature when used in an atmosphere of high temperature and high humidity. This is particularly likely to happen when being transported by ship, so please be careful of the atmosphere when shipping. Condensation is the phenomenon whereby steam condenses to cause water droplets that adhere to the switch when an atmosphere of high temperature and humidity rapidly changes from a high to low temperature or when the switch is quickly moved from a low humidity location to one of high temperature and humidity. Please be careful because condensation can cause adverse conditions such as deterioration of insulation, coil cutoff, and rust. • Condensation or other moisture may freeze on the switch when the temperatures is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags. • The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. • Storage for extended periods of time (including transportation periods) at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported. • In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. –5– AECTB36E 201510-T Technical Terminology & Cautions for Use ■ Types of actuators Shape Pretravel (PT) Overtravel (OT) Operating Force (OF) Vibration Shock Pin plunger Small Small Large Outstanding Appropriate for linear short-stroke action. Pin plunger acts directly on snap action mechanism, enabling high-precision positioning. Amount of movement after operation is smallest among all of the actuators, however, so reliable stopper is required. Spring small plunger Small Medium Large Excellent Used in much the same way as the pin plunger, but is easier to use because the amount of movement after operation is larger. Spring short plunger Small Medium Large Good Pin plunger is short, with large plunger diameter that makes centering easier. Like small spring plunger, amount of movement after operation is large. Panel attachment plunger Small Large Large Good Secured to panel with hex or lock nut; used as manual or mechanical plunger. Amount of movement after operation is extremely large and operation point can be adjusted by changing attachment position. Can be used in combination with low-speed cam. Panel attachment roller plunger Small Large Large Possible This is the panel attachment type with a roller, and can be used with fastmoving cams and dogs.. Hinge lever Large Medium Small Possible Little force required for operation. Appropriate for use with low-speed cams and dogs; has large stroke. Lever available in various shapes to fit operating unit. Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi-circle, enabling use as a simple roller type. Leaf lever Large Large Small Excellent Play in lever is used to assure maximum stroke. Construction provides for space where lever is attached, for outstanding resistance to freezing. Hinge roller lever Large Medium Small Possible This is a hinge lever with a roller, and can be used with high-speed cams and dogs. The force required for pin plunger action is lighter than that of the lever, and the stroke is longer. One way action hinge roller lever Medium Medium Medium Possible This is hinge roller lever type, and can operate in relation to an operating unit from a one way direction, but the roller is bent from the opposite direction and cannot move. This can be used to prevent reverse-direction action. Leaf spring Medium Medium Medium Good This has a leaf spring with offset yield force and has a large stroke. Ideal for driving low-speed cams and cylinders. Fulcrum is fixed for high precision. To prevent leaf damage, movement after operation must be within specified value. Roller leaf spring Medium Medium Medium Good This is a leaf spring with a roller, and can be used with high-speed cams. (OC reversed action groove type) Reverse-action hinge lever Large Small Medium Excellent This is used for low-speed, low-torque cams. The lever comes in various shapes to fit the operating body. (OC reversed action groove type) Reverse-action hinge roller lever Medium Medium Medium Excellent This is a reverse-action hinge lever with a roller and is appropriate for cam operation. Excellent resistance to vibration and impact when not engaged. Classification Features The plunger is constantly pressed down by a coiled spring, and operating the lever induces reverse action. Because the plunger is depressed when not engaged, vibration and shock resistance are excellent. Pressing the plunger too far does not cause abnormal force to be applied to the switch mechanism, so a stable service life is assured. (OC reversed action groove type) Reverse-action hinge roller short lever Small Medium Large Excellent This is a shorter version of the reverse-action hinge lever with a roller and has a larger action force, but is appropriate for cam operation with a short stroke. Excellent resistance to vibration and impact when not engaged. Rotating-action type Large Large Small Possible This is a rotating, light-action type that is ideal for detecting paper, coins, and similar objects. –6– AECTB36E 201510-T
AH1564619
物料型号:AH1 (FJ) SWITCHES

器件简介: - 松下自动化控制目录中的超小型、高精度开关。 - 符合RoHS标准。 - 特点包括紧凑尺寸、轻量级、高精度,可使用M2通用螺钉,一体化成型的端子,以及具有防焊剂渗透的开关体。

引脚分配: - 提供了多种安装孔和端子类型,例如自立PC板端子、直PC板端子、焊接端子、直角端子和左角端子。

参数特性: - 包括操作负载、接触形式(例如AgNi合金接触和Au镀层接触)、适用电流范围和操作力(例如0.74N和1.47N)。

功能详解: - 提供了详细的产品类型表,包括不同操作力和适用电流范围的组合。 - 描述了低电平电路类型(Au镀层接触)的电压和电流范围。 - 提供了不同执行器的操作力和最大操作力的详细表格。

应用信息: - 典型应用包括计算机鼠标、便携终端充电器、电锅、汽车(检测钥匙位置)等。

封装信息: - 提供了详细的尺寸信息和CAD数据,包括自立PC板端子、直PC板端子、焊接端子、PC板直角端子和PC板左角端子的尺寸。

注意事项: - 包括开关体的紧固、选择开关、焊接操作和环境等方面的建议和警告。

技术术语和使用注意事项: - 定义了快动开关的术语,如操作力、释放力、预行程、过行程、运动差动等,并提供了机械特性和电气特性的技术说明。
AH1564619 价格&库存

很抱歉,暂时无法提供与“AH1564619”相匹配的价格&库存,您可以联系我们找货

免费人工找货