0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AKC2621

AKC2621

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    COUNTER LCD 8 CHAR PANEL MOUNT

  • 数据手册
  • 价格&库存
AKC2621 数据手册
KC2S(AKC2)/KE2S(AKE2) POWER-ON COUNTER POWER-ON HOUR METER KC2S Eco-COUNT METER KE2S Eco-HOUR METER Eco-COUNT METER and Eco-HOUR METER are ideal for maintenance of your facilities and machinery. FEATURES Eco-COUNT METER 1. Easy to install on existing machinery Just attach the dedicated CT to your existing cables. There is no need to install any additional cabling. 2. Built-in battery The built-in battery allows the units to be installed anywhere. 3. Economically priced 4. Compact size doesn’t take up space (DIN 24 x 48) Easy to install even in cramped spaces. Eco-HOUR METER Dedicated CT 5. Two installation methods available (Separate models) Two installation methods are available: The extremely easy-to-use one-touch installation, and the installation frame installation, used for timers/counters (protective construction IP66). Select the installation type that suits the location. 6. Letter’s height is 8.7 mm A large LCD panel is used, with a highly legible 8.7 mm letter’s height. 7. Conform to CE marking (EMC directive) Compliance with RoHS Directive PRODUCT TYPES 1. KC2S Eco-COUNT METER Product Name Installation type Installation frame type*2 One-touch installation type Eco-COUNT METER main unit*1 Intermediate power cable*3 Front reset Measurement count range Available 0 to 99999999 — Part No. AKC2421 AKC2621 AKE2811 Notes: 1. Eco-COUNT METER (AKC2421/AKC2621) is a product package consisting of the main unit, a dedicated current transformer (CT), and trunk cable. 2. Only the installation frame installation type includes rubber gasket and installation frame. 3. The maximum allowable current of the intermediate power cable is 15 A. 2. KE2S Eco-HOUR METER Product Name Installation type Installation frame type*2 One-touch installation type Eco-HOUR METER main unit*1 Intermediate power cable*3 Front reset Measurement time range Available 0 to 99999.9h — Part No. AKE2421 AKE2621 AKE2811 Notes: 1. Eco-HOUR METER (AKE2421/AKE2621) is a product package consisting of the main unit, an exclusive use current transformer (CT), and trunk cable. 2. Only the installation frame type includes rubber gasket and installation frame. 3. The maximum allowable current of the intermediate power cable is 15 A. SPECIFICATIONS Item Product name Part No. No. of digits External power supply Counting max. speed Time accuracy Measurement range Detection sensitivity (through current) Min. input signal width Reset input Input method (signal) Display method Breakdown voltage (initial) Insulation resistance (initial) Protective construction*2 Vibration resistance (Functional) Vibration resistance (Destructive) Shock resistance (Functional) Shock resistance (Destructive) Operating temperature Storage temperature Ambient humidity Battery life*3 Mass (weight) Specifications Eco-COUNT METER (Power-on Counter) AKC2421/AKC2621 8 digits Eco-HOUR METER (Power-on Hour Meter) AKE2421/AKE2621 6 digits Not required (built-in battery) 2Hz (CT through current minimum power-up time: 250ms, ON:OFF =1:1) — — ±100ppm (25°C) 0 to 99999999 counts 0 to 99999.9h Counting start: 0.5A to 80A (50/60Hz)*1 Timing start: 0.5A to 80A (50/60Hz)*1 Counting stop: 0.2A (50/60Hz) or less Timing stop: 0.2A (50/60Hz) or less 100ms • Non voltage input using contacts or open collector connection • Input impedance, When shorted: Max.10kΩ, When open: Min.750kΩ • Residual voltage: Max. 0.5V 7-segment LCD Between live and dead metal parts: 1,000V AC for 1 minute. Between live and dead metal parts: Min. 100MΩ (measured at 500 V DC) IEC Standard IP66 (only front panel with rubber gasket) 10 to 55 Hz: 1 cycle/min., signal amplitude of 0.15mm .006inch (10 min. on 3 axes) 10 to 55 Hz: 1 cycle/min., signal amplitude of 0.375mm .015inch (1 hr. on 3 axes) Min. 98m 321.522ft/s2 (4 times on 3 axes) Min. 294m 964.567ft/s2 (5 times on 3 axes) –10 to +50°C +14 to +122°F (without frost or dew) –25 to +65°C –13 to +149°F (without frost or dew) 35 to 85% RH (at 20°C non-condensing) 7 years (at 25°C 77°F) 10 years (at 25°C 77°F) Approx. 110g (Dedicated CT included) Approx. 105g (Dedicated CT included) Notes: 1. Maximum cable diameter is 10 mm. 2. See page 13, “NOTES 4. Waterproofing Construction” for details about the protective construction (IP66). 3. Battery life is calculated based on the above conditions. This is not a guarantee of actual battery life. Please use this as a guide for replacing the battery only. The actual battery life may be shortened, depending on the utilization environment of the main unit. !LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O ,TD 26/03/2013 KC2S(AKC2)/KE2S(AKE2) 2. Dedicated CT Item Diameter of conductor to be measured Breakdown voltage (Initial value) Insulation resistance (Initial value) Allowable number of detachments/attachments Vibration resistance (Functional) Vibration resistance (Destructive) Shock resistance (Functional) Shock resistance (Destructive) Operating temperature range Storage temperature Mass (Weight) Ambient humidity Specification 10 dia. (max.) 1,000 Vrms AC for 1min: Between core and output connector terminal Min. 100MΩ: Between core and output terminal (at 500V DC) Approx. 100 times 10 to 55 Hz: 1 cycle/ min single amplitude of 0.15 mm .006 inch (10 min on 3 axes) 10 to 55 Hz: 1 cycle/ min single amplitude of 0.375 mm .015 inch (1 h on 3 axes) Min. 98 m 321.522 ft./s2 (4 times on 3 axes) Min. 294 m 964.567 ft./s2 (5 times on 3 axes) –10°C to +50°C +14°F to 122°F (Without frost or dew) –20°C to +60°C –4°F to 140°F (Without frost or dew) Approx. 55g 1.94oz (trunk cable included) 35 to 80% R.H. (at 20°C non-condensing) Note: For Eco-COUNT METER and Eco-HOUR METER, this CT is supplied together. APPLICABLE STANDARDS (EMI) EN61000-6-4 Radiated emission electric field strength Noise terminal voltage (EMS) EN61000-6-2 Static discharge immunity RF electromagnetic field immunity EFT/B immunity Conductivity noise immunity Power frequency electric field immunity EMC EN55011 Group 1 Class A EN55011 Group 1 Class A EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-6 EN61000-4-8 4 kV contact 10 V/m AM (80 MHz to 1 GHz) 1 kV (Signal line) 10 V/m AM (0.15 MHz to 80 MHz) 30 A/m (50Hz) PART NAME Eco-HOUR METER h RESET KE2S Front reset key Lock switch 1. Main unit 1) Front reset key This key resets the count value of Eco-COUNT METER and elapsed time of Eco-HOUR METER. It does not work when the lock switch is ON. Note that frequent operation may shorten battery life. 2) Lock switch (Refer to chart on left) Ineffective the front reset key Note: LCD side is ON (reset ineffective); terminal block side is OFF (reset effective) (Terminal block side) OFF∗ (LCD side) ON 2. Dedicated CT Lock switch 1) (Mark on the unit 䡺 Notes: 1. ∗ Factory setting. 2. Make the switch setting before installing to panel. 3. Common to Eco-COUNT METER and Eco-HOUR METER. mm inch General tolerance: ±1.0 ±.039 DIMENSIONS (Common to Eco-COUNT METER and Eco-HOUR METER) 44.8 1.764 2. Dedicated CT 1. Main unit 1) One touch installation type 26 1.024 54.4 2.142 1 .039 23 .906 1 .039 0 0 dia. 10–0.5 dia. .394 –.020 10.4 .409 (44) (1.732) 48 1.890 5 .197 39 1.535 Eco-COUNT METER 27 1.063 24 .945 22 .866 13.5 .531 KC2S 7 .276 44.8 1.764 2) Installation frame type 150±5 5.906±.197 54.4 2.142 10.4 .409 (44) (1.732) 3. Trunk Cable 48 1.890 5 .197 Eco-COUNT METER 1000±50 39.37±1.969 24 .945 22 .866 KC2S 7 .276 Front reset key Note: The trunk cable connects the main unit and dedicated CT. It is included with the main unit. !LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O ,TD 26/03/2013 KC2S(AKC2)/KE2S(AKE2) INSTALLATION 1. Panel installation 1) One-touch installation type 2) Installation frame type 3) Panel cut-out dimensions Mounting screws (attached to mounting frame) Mounting frame ATH3803 (attached) 45+0.6 0 1.772+.024 0 22.2+0.3 0 .874+.012 0 Panel (thickness: 1 to 4.5mm .039 to .177inch) Rubber spacer (attached) Rubber gasket ATH3804 (attached) Panel (thickness: 1 to 4.5mm .039 to .177inch) Note: When installing to a 4.5mm .177 thick panel, remove the rubber spacer first. 1. Panel installation 1) Installation using plastic magnet Attach the unit to the equipment case. 2) Installation via double-sided tape Use this method in places where a plastic magnet cannot be used or where installation strength is insufficient. 3) Installation via clamp Clamp to one of the cables inside the equipment, etc. Note: Take careful note of the precautions for use in the catalog or user’s manual before using an Eco-COUNT METER or Eco-HOUR METER installed by one of the methods described above. 3. Terminal layout and wiring diagrams (Common to Eco-COUNT METER and Eco-HOUR METER) CT input Reset input 1 2 3 or 4 Notes: 1. Terminal 2 and 4 are connected inside. 2. The CT does not have polarity OPTIONS • Intermediate power cable (AKE2811) 200±10 7.874±.394 Note: We recommend using an intermediate power cable when attaching the dedicated CT to a non-“Y” split power cable EXPLANATION OF OPERATION KC2S Eco-COUNT METER 1. The number of power-ons is counted by sending through current through the dedicated CT. 2. When the number of power ons (measured value) reaches the full scale, it reverts to 0, and starts counting again from 0. 3. When the reset terminal input is set to on, the display will read “0”. This does not count during reset input. Power on detection of dedicated CT 4. Use the reset key on the front of the unit to reset manually. The display will be blank while the reset key is being pressed. ON OFF ON Reset input Count value OFF 0 1 2 99999999 0 1 2 0 Full scale Note: ∗ If reset input is shut off while CT through current is on, the count will be set to 1. !LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O ,TD 26/03/2013 1 ∗ KC2S(AKC2)/KE2S(AKE2) KE2S Eco-HOUR METER 1. The power-on time is measured when the dedicated CT detects a through current. 2. When the elapsed time (number of hours measured) reaches the full scale, the display reverts to 0, and starts timing again from 0. 3. When the reset input is set to on, the display will read “0”. This does not time during reset input. 4. Use the reset key on the front of the unit to reset manually. The display will be blank while the reset key is being pressed. ON ON Power on detection of dedicated CT OFF ON Reset input OFF Fall scale Powered on time 0 RESET INPUT (Common to Eco-COUNT METER and Eco-HOUR METER) 1. Contact input 2. Transistor input (NPN transistor) Dedicated CT input 1 2 3 Reset input 4 Dedicated CT input 5 1 2 3 6 4 Reset input 0V (Terminal 2 and 4 are connected inside.) (Terminal 2 and 4 are connected inside.) Notes: 1. When using contact input, since current flow is small from reset input terminal 3, please use relays and switches with high contact reliabillity. 2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage950V, leakage current < 1μA) NOTES 1. Main unit 1) Reset input (1) Never apply voltage to reset input. This can cause damage to the internal elements. (2) Since the current flow is very small from reset input terminal 3, please use relays and switches with high contact reliabillity. When inputting a reset by a transistor’s open collector use a transistor for small signals in which ICBO is 1μA or less and always input with no voltage. (3) When wiring, try to keep all the input lines to the reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Note that power cable floating capacitance in excess of 500 pF (10m on 2 mm2 parallel cables) could cause malfunctions. Take particular care of inter-cable capacitance when using shielded cables. 2) How to reset multiple panel installation type units all at once. D D 3 4 D 3 4 2. Dedicated CT 1) Measured power is AC (50 Hz/60 Hz). Will not function when used with DC power. 2) When clamping to the power cable to be measured, clamp only one of the live wires. 3) Avoid usage that bends the lead wire. 4) When clamping, make sure that no dust or other foreign matter intercedes between the clamp and contact. Foreign matter could impact detection sensitivity. 3. Insulation sheet Before using, please pull and remove the insulation sheet in the direction of the arrow. In consideration that the product might be stored for long periods without being used, an insulation sheet is inserted before shipping. Remove the insulation sheet and press the front reset key. • Installation frame type Tr 3 4 or Notes: 1. Use the following as a guide for choosing transistors used for input (Tr). Leakage current < 1μΑ 2. Use as small a diode (D) as possible in the forward voltage so that the voltage between terminals 3 and 4 during reset input meets the standard value (0.5V). (At IF = 20μA, forward voltage 0.1 V or less.) Insulation sheet Reset key • One-touch installation type Insulation sheet 4. Waterproof construction The operation part is constructed to prevent water from entering the unit and a rubber gasket is provided to prevent water from entering the gap between the unit and the panel cutout. There must be sufficient pressure applied to the rubber gasket to prevent water from entering. Be sure to use the mounting screws when using the mounting frame (ATH3803). Attaching the one-touch installation type to a panel will not waterproof the panel surface. Mounting frame (ATH3803) (attached) 5. Do not use in the following environments 1) In places where the temperature changes drastically. 2) In places where humidity is high and there is the possibillity of dew. (When dew forms the display may vanish and other display errors may occur.) Reset key !LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O ,TD 26/03/2013 KC2S(AKC2)/KE2S(AKE2) 6. Cautions regarding battery replacement 1) Remove wiring before replacing the battery. You may be electrocuted if you come into contact to a part where high voltage is applied. 2) Make sure you are not carrying a static electric charge when replacing the battery. 3) Battery replacement procedure • Installation frame type (1) Remove the battery cover 1 from the case. (2) Remove the battery 2 from the side of the case. The battery will come loose if you put the battery side face down and lightly shake the unit. (3) Before inserting wipe clean the surface of the battery. Insert the battery 4 with the + and – sides in the proper position. (4) After replacing the battery return the battery cover 5 to the case. Verify that the hook of the battery cover is properly engaged. Before using press the reset key 6 on the front. • One-touch installation type (1) Using a tool remove the up/down hook of the case 1. Pull the unit 2 away from the case. (2) Remove the battery 3 from the side of the unit. Do not touch the display or other parts. (3) Before inserting wipe clean the surface of the battery. Insert the battery 5 with the + and – sides in the proper position. (4) After replacing the batery return the unit 6 to the case. Verify that the hook of the case has properly engaged. Before using press the reset key 7 on the front. • Installation frame type 1 (1) (2) 2 (3) 5 (4) + side – side 4 6 • One-touch installation type Tool 1 (1) (2) 2 3 1 (3) (4) 6 + side – side 5 !LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O ,TD 26/03/2013 7
AKC2621 价格&库存

很抱歉,暂时无法提供与“AKC2621”相匹配的价格&库存,您可以联系我们找货

免费人工找货