KC2S(AKC2)/KE2S(AKE2)
POWER-ON COUNTER
POWER-ON HOUR METER
KC2S Eco-COUNT METER
KE2S Eco-HOUR METER
Eco-COUNT METER and Eco-HOUR METER are ideal for maintenance
of your facilities and machinery.
FEATURES
Eco-COUNT METER
1. Easy to install on existing machinery
Just attach the dedicated CT to your existing
cables. There is no need to install any
additional cabling.
2. Built-in battery
The built-in battery allows the units to be
installed anywhere.
3. Economically priced
4. Compact size doesn’t take up space
(DIN 24 x 48)
Easy to install even in cramped spaces.
Eco-HOUR METER
Dedicated CT
5. Two installation methods available
(Separate models)
Two installation methods are available: The
extremely easy-to-use one-touch installation,
and the installation frame installation, used for
timers/counters (protective construction IP66).
Select the installation type that suits the
location.
6. Letter’s height is 8.7 mm
A large LCD panel is used, with a highly
legible 8.7 mm letter’s height.
7. Conform to CE marking (EMC directive)
Compliance with RoHS Directive
PRODUCT TYPES
1. KC2S Eco-COUNT METER
Product Name
Installation type
Installation frame type*2
One-touch installation type
Eco-COUNT METER main unit*1
Intermediate power cable*3
Front reset
Measurement count range
Available
0 to 99999999
—
Part No.
AKC2421
AKC2621
AKE2811
Notes: 1. Eco-COUNT METER (AKC2421/AKC2621) is a product package consisting of the main unit, a dedicated current transformer (CT), and trunk cable.
2. Only the installation frame installation type includes rubber gasket and installation frame.
3. The maximum allowable current of the intermediate power cable is 15 A.
2. KE2S Eco-HOUR METER
Product Name
Installation type
Installation frame type*2
One-touch installation type
Eco-HOUR METER main unit*1
Intermediate power cable*3
Front reset
Measurement time range
Available
0 to 99999.9h
—
Part No.
AKE2421
AKE2621
AKE2811
Notes: 1. Eco-HOUR METER (AKE2421/AKE2621) is a product package consisting of the main unit, an exclusive use current transformer (CT), and trunk cable.
2. Only the installation frame type includes rubber gasket and installation frame.
3. The maximum allowable current of the intermediate power cable is 15 A.
SPECIFICATIONS
Item
Product name
Part No.
No. of digits
External power supply
Counting max. speed
Time accuracy
Measurement range
Detection sensitivity (through current)
Min. input signal width
Reset input
Input method (signal)
Display method
Breakdown voltage (initial)
Insulation resistance (initial)
Protective construction*2
Vibration resistance (Functional)
Vibration resistance (Destructive)
Shock resistance (Functional)
Shock resistance (Destructive)
Operating temperature
Storage temperature
Ambient humidity
Battery life*3
Mass (weight)
Specifications
Eco-COUNT METER (Power-on Counter)
AKC2421/AKC2621
8 digits
Eco-HOUR METER (Power-on Hour Meter)
AKE2421/AKE2621
6 digits
Not required (built-in battery)
2Hz (CT through current minimum power-up time: 250ms, ON:OFF =1:1)
—
—
±100ppm (25°C)
0 to 99999999 counts
0 to 99999.9h
Counting start: 0.5A to 80A (50/60Hz)*1
Timing start: 0.5A to 80A (50/60Hz)*1
Counting stop: 0.2A (50/60Hz) or less
Timing stop: 0.2A (50/60Hz) or less
100ms
• Non voltage input using contacts or open collector connection
• Input impedance, When shorted: Max.10kΩ, When open: Min.750kΩ
• Residual voltage: Max. 0.5V
7-segment LCD
Between live and dead metal parts: 1,000V AC for 1 minute.
Between live and dead metal parts: Min. 100MΩ (measured at 500 V DC)
IEC Standard IP66 (only front panel with rubber gasket)
10 to 55 Hz: 1 cycle/min., signal amplitude of 0.15mm .006inch (10 min. on 3 axes)
10 to 55 Hz: 1 cycle/min., signal amplitude of 0.375mm .015inch (1 hr. on 3 axes)
Min. 98m 321.522ft/s2 (4 times on 3 axes)
Min. 294m 964.567ft/s2 (5 times on 3 axes)
–10 to +50°C +14 to +122°F (without frost or dew)
–25 to +65°C –13 to +149°F (without frost or dew)
35 to 85% RH (at 20°C non-condensing)
7 years (at 25°C 77°F)
10 years (at 25°C 77°F)
Approx. 110g (Dedicated CT included)
Approx. 105g (Dedicated CT included)
Notes: 1. Maximum cable diameter is 10 mm.
2. See page 13, “NOTES 4. Waterproofing Construction” for details about the protective
construction (IP66).
3. Battery life is calculated based on the above conditions.
This is not a guarantee of actual battery life.
Please use this as a guide for replacing the battery only.
The actual battery life may be shortened, depending on the utilization environment of
the main unit.
!LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O,TD
26/03/2013
KC2S(AKC2)/KE2S(AKE2)
2. Dedicated CT
Item
Diameter of conductor to be measured
Breakdown voltage (Initial value)
Insulation resistance (Initial value)
Allowable number of detachments/attachments
Vibration resistance (Functional)
Vibration resistance (Destructive)
Shock resistance (Functional)
Shock resistance (Destructive)
Operating temperature range
Storage temperature
Mass (Weight)
Ambient humidity
Specification
10 dia. (max.)
1,000 Vrms AC for 1min: Between core and output connector terminal
Min. 100MΩ: Between core and output terminal (at 500V DC)
Approx. 100 times
10 to 55 Hz: 1 cycle/ min single amplitude of 0.15 mm .006 inch (10 min on 3 axes)
10 to 55 Hz: 1 cycle/ min single amplitude of 0.375 mm .015 inch (1 h on 3 axes)
Min. 98 m 321.522 ft./s2 (4 times on 3 axes)
Min. 294 m 964.567 ft./s2 (5 times on 3 axes)
–10°C to +50°C +14°F to 122°F (Without frost or dew)
–20°C to +60°C –4°F to 140°F (Without frost or dew)
Approx. 55g 1.94oz (trunk cable included)
35 to 80% R.H. (at 20°C non-condensing)
Note: For Eco-COUNT METER and Eco-HOUR METER, this CT is supplied together.
APPLICABLE STANDARDS
(EMI) EN61000-6-4
Radiated emission electric field strength
Noise terminal voltage
(EMS) EN61000-6-2
Static discharge immunity
RF electromagnetic field immunity
EFT/B immunity
Conductivity noise immunity
Power frequency electric field immunity
EMC
EN55011 Group 1 Class A
EN55011 Group 1 Class A
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-8
4 kV contact
10 V/m AM (80 MHz to 1 GHz)
1 kV (Signal line)
10 V/m AM (0.15 MHz to 80 MHz)
30 A/m (50Hz)
PART NAME
Eco-HOUR METER
h
RESET
KE2S
Front reset key
Lock switch
1. Main unit
1) Front reset key
This key resets the count value of Eco-COUNT METER and elapsed
time of Eco-HOUR METER.
It does not work when the lock switch is ON.
Note that frequent operation may shorten battery life.
2) Lock switch (Refer to chart on left)
Ineffective the front reset key
Note: LCD side is ON (reset ineffective); terminal block side is OFF (reset effective)
(Terminal block side)
OFF∗
(LCD side)
ON
2. Dedicated CT
Lock switch
1)
(Mark on the unit 䡺
Notes: 1. ∗ Factory setting.
2. Make the switch setting before installing to panel.
3. Common to Eco-COUNT METER and Eco-HOUR METER.
mm inch General tolerance: ±1.0 ±.039
DIMENSIONS
(Common to Eco-COUNT METER
and Eco-HOUR METER)
44.8
1.764
2. Dedicated CT
1. Main unit
1) One touch installation type
26
1.024
54.4
2.142
1
.039
23
.906
1
.039
0
0
dia.
10–0.5
dia. .394 –.020
10.4
.409
(44)
(1.732)
48
1.890
5
.197
39
1.535
Eco-COUNT METER
27
1.063
24
.945
22
.866
13.5
.531
KC2S
7 .276
44.8
1.764
2) Installation frame type
150±5
5.906±.197
54.4
2.142
10.4
.409
(44)
(1.732)
3. Trunk Cable
48
1.890
5
.197
Eco-COUNT METER
1000±50
39.37±1.969
24
.945
22
.866
KC2S
7 .276
Front reset key
Note: The trunk cable connects the main unit and dedicated CT.
It is included with the main unit.
!LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O,TD
26/03/2013
KC2S(AKC2)/KE2S(AKE2)
INSTALLATION
1. Panel installation
1) One-touch installation type
2) Installation frame type
3) Panel cut-out dimensions
Mounting screws
(attached to
mounting frame)
Mounting frame
ATH3803
(attached)
45+0.6
0
1.772+.024
0
22.2+0.3
0
.874+.012
0
Panel (thickness:
1 to 4.5mm
.039 to .177inch)
Rubber spacer
(attached)
Rubber gasket
ATH3804
(attached)
Panel (thickness:
1 to 4.5mm .039 to .177inch)
Note: When installing to a 4.5mm .177 thick panel, remove the
rubber spacer first.
1. Panel installation
1) Installation using plastic magnet
Attach the unit to the equipment case.
2) Installation via double-sided tape
Use this method in places where a plastic
magnet cannot be used or where installation
strength is insufficient.
3) Installation via clamp
Clamp to one of the cables inside the
equipment, etc.
Note: Take careful note of the precautions for use in the catalog or user’s manual before using an Eco-COUNT METER or Eco-HOUR METER installed by one of the methods described above.
3. Terminal layout and wiring diagrams
(Common to Eco-COUNT METER and Eco-HOUR METER)
CT input
Reset input
1
2
3
or
4
Notes: 1. Terminal 2 and 4 are connected inside.
2. The CT does not have polarity
OPTIONS
• Intermediate power cable (AKE2811)
200±10
7.874±.394
Note: We recommend using an intermediate power cable when attaching the dedicated CT to a non-“Y” split power cable
EXPLANATION OF OPERATION
KC2S Eco-COUNT METER
1. The number of power-ons is counted by
sending through current through the
dedicated CT.
2. When the number of power ons
(measured value) reaches the full scale,
it reverts to 0, and starts counting again
from 0.
3. When the reset terminal input is set to
on, the display will read “0”. This does not
count during reset input.
Power on detection of
dedicated CT
4. Use the reset key on the front of the unit
to reset manually. The display will be blank
while the reset key is being pressed.
ON OFF
ON
Reset input
Count value
OFF
0
1
2
99999999
0
1
2
0
Full scale
Note: ∗ If reset input is shut off while CT through current is on, the count will be set to 1.
!LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O,TD
26/03/2013
1
∗
KC2S(AKC2)/KE2S(AKE2)
KE2S Eco-HOUR METER
1. The power-on time is measured when the
dedicated CT detects a through current.
2. When the elapsed time (number of hours
measured) reaches the full scale, the
display reverts to 0, and starts timing again
from 0.
3. When the reset input is set to on, the
display will read “0”. This does not time
during reset input.
4. Use the reset key on the front of the unit
to reset manually. The display will be blank
while the reset key is being pressed.
ON
ON
Power on detection of
dedicated CT
OFF
ON
Reset input
OFF
Fall scale
Powered on time
0
RESET INPUT (Common to Eco-COUNT METER and Eco-HOUR METER)
1. Contact input
2. Transistor input
(NPN transistor)
Dedicated CT
input
1
2
3
Reset
input
4
Dedicated CT
input
5
1
2
3
6
4
Reset
input
0V
(Terminal 2 and 4 are connected inside.)
(Terminal 2 and 4 are connected inside.)
Notes: 1. When using contact input, since current flow is small from reset input terminal 3, please use relays and switches with high contact reliabillity.
2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting.
(Collector withstand voltage950V, leakage current < 1μA)
NOTES
1. Main unit
1) Reset input
(1) Never apply voltage to reset input. This can
cause damage to the internal elements.
(2) Since the current flow is very small from
reset input terminal 3, please use relays and
switches with high contact reliabillity.
When inputting a reset by a transistor’s open
collector use a transistor for small signals in
which ICBO is 1μA or less and always input with
no voltage.
(3) When wiring, try to keep all the input lines
to the reset inputs as short as possible and
avoid running them together with high voltage
and power transmission lines or in a power
conduit.
Note that power cable floating capacitance in
excess of 500 pF (10m on 2 mm2 parallel
cables) could cause malfunctions. Take
particular care of inter-cable capacitance
when using shielded cables.
2) How to reset multiple panel installation type
units all at once.
D
D
3 4
D
3 4
2. Dedicated CT
1) Measured power is AC (50 Hz/60 Hz).
Will not function when used with DC power.
2) When clamping to the power cable to be
measured, clamp only one of the live wires.
3) Avoid usage that bends the lead wire.
4) When clamping, make sure that no dust or
other foreign matter intercedes between the
clamp and contact. Foreign matter could
impact detection sensitivity.
3. Insulation sheet
Before using, please pull and remove the
insulation sheet in the direction of the arrow.
In consideration that the product might be
stored for long periods without being used, an
insulation sheet is inserted before shipping.
Remove the insulation sheet and press the
front reset key.
• Installation frame type
Tr
3 4
or
Notes: 1. Use the following as a guide for choosing
transistors used for input (Tr).
Leakage current < 1μΑ
2. Use as small a diode (D) as possible in the forward
voltage so that the voltage between terminals 3 and
4 during reset input meets the standard value
(0.5V).
(At IF = 20μA, forward voltage 0.1 V or less.)
Insulation sheet
Reset key
• One-touch installation type
Insulation sheet
4. Waterproof construction
The operation part is constructed to prevent
water from entering the unit and a rubber
gasket is provided to prevent water from
entering the gap between the unit and the
panel cutout.
There must be sufficient pressure applied to
the rubber gasket to prevent water from
entering.
Be sure to use the mounting screws when
using the mounting frame (ATH3803).
Attaching the one-touch installation type to a
panel will not waterproof the panel surface.
Mounting frame
(ATH3803) (attached)
5. Do not use in the following environments
1) In places where the temperature changes
drastically.
2) In places where humidity is high and there
is the possibillity of dew. (When dew forms the
display may vanish and other display errors
may occur.)
Reset key
!LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O,TD
26/03/2013
KC2S(AKC2)/KE2S(AKE2)
6. Cautions regarding battery replacement
1) Remove wiring before replacing the battery.
You may be electrocuted if you come into
contact to a part where high voltage is applied.
2) Make sure you are not carrying a static
electric charge when replacing the battery.
3) Battery replacement procedure
• Installation frame type
(1) Remove the battery cover 1 from the
case.
(2) Remove the battery 2 from the side of the
case.
The battery will come loose if you put the
battery side face down and lightly shake
the unit.
(3) Before inserting wipe clean the surface of
the battery.
Insert the battery 4 with the + and – sides
in the proper position.
(4) After replacing the battery return the
battery cover 5 to the case. Verify that the
hook of the battery cover is properly
engaged.
Before using press the reset key 6 on the
front.
• One-touch installation type
(1) Using a tool remove the up/down hook of
the case 1.
Pull the unit 2 away from the case.
(2) Remove the battery 3 from the side of the
unit. Do not touch the display or other
parts.
(3) Before inserting wipe clean the surface of
the battery.
Insert the battery 5 with the + and – sides
in the proper position.
(4) After replacing the batery return the unit 6
to the case. Verify that the hook of the case
has properly engaged.
Before using press the reset key 7 on the
front.
• Installation frame type
1
(1)
(2)
2
(3)
5
(4)
+ side
– side
4
6
• One-touch installation type
Tool
1
(1)
(2)
2
3
1
(3)
(4)
6
+ side
– side
5
!LL2IGHTS2ESERVEDÚ#OPYRIGHT0ANASONIC%LECTRIC7ORKS#O,TD
26/03/2013
7
很抱歉,暂时无法提供与“AKE2811”相匹配的价格&库存,您可以联系我们找货
免费人工找货