0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AKT4R111200

AKT4R111200

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    CONTROLTEMPRELOUT100-240V

  • 数据手册
  • 价格&库存
AKT4R111200 数据手册
Temperature Controller KT SERIES Conforming to EMC Directive Recognition Upgraded KT4, KT8 and KT9 models Improved visibility, operability and performance! Upgraded Upgraded Upgraded KT4R series KT8R series KT9R series [48 × 48 × 58.8 m mm] [1.890 × 1.890 × 2.315 in] [48 × 96 × 58.8 m mm] [1.890 × 3.780 × 2.315 in] [96 × 96 × 58.8 m mm] [3.780 × 3.780 × 2.315 in] KT4H KT2 series KT7 series [48 × 24 × 98.5 mm] [1.890 × 0.945 × 3.878 in] [22.5 × 75 × 100 mm] [0.886 × 2.953 × 3.937 in] KT4H / KT4B series [48 × 48 × 56 mm] [1.890 × 1.890 × 2.205 in] KT4B Extensive line-up with models to match application and space 2015.07 panasonic.net/id/pidsx/global Upgraded models Features of KT4R, KT8R and KT9R Smooth initial setting and setting adjustment Fine control of heat capacity Operation startup can begin after using initial setting mode to enter the control values required before first use, and after entering values for items such as frequently used and frequently changed settings. Smooth operation is enabled at initial startup and after changing settings. Sampling period rate half (1/2 times) from previous model: high speed 125 ms processing implemented. With twice the responsiveness, it is possible to more finely carry out control, for example, of the heat capacity. Built-in easy programming function Built-in rearing auto tuning function Easy programmed control made possible using nine-step setting procedure. By entering specific target values for each indicated period, freely selectable temperature control is possible. The built-in rearing auto tuning function uses the step response method. From temperature rise behavior alone, it can calculate the PID constants. It is possible to calculate constants, even when auto tuning cannot be used to generate them. Because an ON / OFF operation is unnecessary, there is no disruption in control. Example: From start of programmed control  Perform control so it becomes 200 °C 392 °F after 1 hour. °F until1after 2 hours  Maintain 200 °C 392 3 2 5 Step 4  Perform control so it becomes 300 °C 572 °F after 30 minutes. ( ) 200 392 SV °C °F Step ( ) SV °C °F Time ( ) Wait °C °F 300 °C 572 °F 1 Time 2 1:00 3 300 200 200 392Wait °C 392 10 572 °F 50 2:00 1:00 0:30 300 °C 10 572 °F 0 10 32 50 50 ( ) 200 392 4 2:00 300 0 572 32 1:00 0 32 300 572 300 572 5 1:00 0 10 32 0 32 50 2:00 0:30 Temperature SV value 0 32 2:00 0 32 Temperature SV value 0 32 200 °C 392 °F 200 °C 392 °F 0 °C 32 °F 0 °C 32 °F Time Rearing AT start point  Control parameter measuring Rearing AT start point     Calculation of PID  Control with calculated constants PID constants Time     Calculation of PID  Control with calculated constants PID constants Other features  Control parameter measuring •V  isibility and operability improved with large display and key size. • Unit 60 mm 2.362 in approx. long: compact design saves space. • With DC current output, can be used as simple signal converter. Shared features of KT series Multi-input sensors Versatile thermocouple, RTD, DC voltage and DC current input for temperature detecting sensors Simple operation enables highly accurate temperature control All required operations can be enabled by the front keys and highly accurate PID control mode ensures an input span of ±0.2 %. DIN Rail mounting types are aligned taking global market demand into consideration (for KT7 series) Improved visibility and ease of operation More compact than before The KT4H / KT4B series features improved visibility with a process value (PV) character height of 12 mm 0.472 in and an 11-segment display. Connectable to a PC, it offers a full range of control and communication functions. Communication specification uses RS485 (Modbus protocol) (Sample System Configuration) FPΣ Programmable Controller The KT7 series is equipped with DIN rail mounting complying to DIN standards. Furthermore, because its control panel is compact, the KT7 series saves space. Nine step pattern control possible. (for KT2 series) RS485 For KT2 series, despite DIN 48 x 24 size, selection is possible of control with fixed set point and nine step pattern control. Meets market demands for cost-effectiveness The KT series offers both economy and high performance. The KT series complies with UL/c-UL standard and CE marking. 2 Up to 31 units can be connected *1 Only on type equipped with communications function. *2 In the configuration above, the FPΣ requires a communication cassette (FPG-COM3). *3 Modbus protocol is a communication protocol developed for PLCs by Modicon Inc. KT SERIES Temperature Controller PARTS AND FUNCTIONS n KT2 series 3 4 5 ① PV / SV display (red) �������������������Indicates the process value (PV) and setting value (SV). During setting mode, characters and setting value of the setting item are indicated in turn. ② MEMO / STEP display (green) ����Indicates the memory number during fixed value control. Indicates step number during program control. ③ PV indicator (red) ������������������������Lights up when the input value is indicated. ④ SV indicator (green) ��������������������Lights up when main setting value is indicated. ⑤ AT indicator (yellow) ��������������������Flashes during auto-tuning (AT) ⑥ T / R indicator (yellow) ����������������Flashes during serial communication (Lit while sending data, Unlit while receiving data) ⑦ OUT indicator (green) �����������������Lights up when control output or OUT1 (heating side) output (option: heating / cooling control) is ON. For DC current output type, it flashes corresponding to the manipulated variable in a 0.25 second cycle ⑧ EV1 indicator (red) ����������������������Lights up when event output 1 or OUT2 (cooling side) output (option: heating / cooling control) is ON. ⑨ EV2 indicator (red) ����������������������Lights up when event output 2 is ON. ⑩ Increase key ��������������������������������Increases the numeric value. ⑪ Decrease key ������������������������������Decreases the numeric value. ⑫ Mode key �������������������������������������Selects the setting mode or registers the setting value. By pressing the mode key, the setting value or selected value can be registered ⑬ OUT / OFF key ����������������������������The control output OUT / OFF or program control RUN / STOP can be switched. 6 7 1 8 2 9 10 11 12 13 n KT4R series n KT8R series 1 1 8 2 7 2 5 6 8 3 4 3 n KT9R series 5 1 4 6 n KT7 series 7 1 8 ① PV display ����������������������� Indicates the process value (PV). ② SV display ����������������������� Indicates the setting value (SV) ③ Increase key ������������������� Increases the numeric value ④ Decrease key ����������������� Decreases the numeric value ⑤ Mode key ������������������������ Selects the setting mode or registers the setting value. ⑥ OUT / OFF key ��������������� The control output ON / OFF, auto / manual control function or program control can be switched. (Not available in KT7 series) ⑦ STEP / MEMO display ��� Indicates the step number (program control) and set value memory number (for KT8R and KT9R) ⑧ Action indicators (Not available in KT7 series) •O1 ������Lights up when control output 1 is ON. Lights up when heating control output (option) is ON. For DC power output type, it flashes corresponding to the manipulated variable in a 125 ms cycle •O2 ������Lights up when cooling control output (option) is ON. •EV1 ����Lights when Alarm 1 output is ON. •EV2 ���Lights when Alarm 2 output (option) is ON. •AT ������Flashes during auto-tuning or auto-reset •T/R �����Lights during serial communication (option) TX output. (for KT4R only) 2 2 5 3 6 3 4 5 4 Note 1: Color selection is the same for each size. n KT4H / KT4B series ① ② ③ ④ ⑤ ⑦ ⑥ ⑧ ⑨ (Bottom side) ① Action indicators (backlight: orange) °F °C �������������������Lights respectively when temperature unit °F / °C is selected T / R ���������������������Lights during serial communication (option) TX output. AT ������������������������Flashes during auto-tuning or auto-reset OUT1 �������������������Lights when control output is ON or heating output (option) is ON. For DC current output type, it flashes corresponding to the manipulated variable in 0.25 second cycles. OUT2 �������������������Lights when cooling output (option) is ON. EVT1 �������������������Lights when alarm 1 output is ON. EVT2 �������������������Lights when alarm 2 output (option) is ON or heater burnout alarm output (option) is ON. LOCK �������������������Lights when lock 1, lock 2 or lock 3 is selected. ② MEMO display ����Indicates the set value memory number. (backlight: green) ③ PV display �����������Indicates the process value (PV). (backlight: red / orange / green) ④ SV display �����������Indicates the set value (SV). (backlight: green) ⑤ Mode key ������������Selects the setting mode and registers the set value. ⑥ OUT / OFF key ���The control output ON / OFF or auto / manual control function can be switched. ⑦ Increase key �������Increases the numeric value ⑧ Decrease key �����Decreases the numeric value ⑨ Tool connector ����By connecting the dedicated cable, the following operations can be conducted from the external computer. • Reading and setting of SV, PID and various set values • Reading of PV and action status • Function change 3 KT SERIES Temperature Controller PRODUCT TYPES n KT2 series (Ash grey) Base model AKT2 Power supply Sensor input 1 2 Control output 1 Alarm output Heating / Heater Communication cooling burnout function 1 2 3 2 0 0 Blank 1 1 0 Blank 1 0 0 1 0 1 0 1 Description 48 × 24 × 98.5 mm 1.890 × 0.945 × 3.878 in 100 to 240 V AC Must be specified 24 V AC / DC Multi-input (Thermocouple, RTD, DC voltage and DC current) Relay contact output 1a 250 V AC 3 A Must be Non-contact voltage output (for SSR drive) specified DC current When both heating / cooling and communication functions are not added Relay contact output (alarm 1) ...... Can be used Open collector output (alarm 2) ...... Can be used When only heating / cooling function is added Relay contact output (alarm 1) ...... Cannot be used Open collector output (alarm 2) ...... Can be used When only communication function is added Relay contact output (alarm 1) ...... Can be used Open collector output (alarm 2) ...... Cannot be used When both heating / cooling and communication functions are added Relay contact output (alarm 1) ...... Cannot be used Open collector output (alarm 2) ...... Cannot be used Notes: 1) When heating / cooling is selected, alarm output 1 cannot be used. 2) When the communication function is selected, alarm output 2 cannot be used. Model No. search method Example: Basic functions + optional functions (Heating / cooling: relay contact output + communication function) • For KT2 series, the option function is only the following 4 patterns. AKT21200 Blank AKT211001 AKT21110 Blank AKT210101 • Model No.: AKT21110101 Options Please refer to page 15. Product name Model No. Shunt resistor (for current input) AKT4810 Terminal cover AKT2801 Note: When current input is specified, a shunt resistor (sold separately) is required. n KT4R series (Black) Base model Power supply Sensor input Alarm output Control output 1 (1 point) 1 (Relay contact) AKT4R 1 (100 to 240 V AC) Heating / cooling Heater burnout Communication function Blank (Not available) 2 (Non-contact voltage) Blank (Not available) 0 0 1 (serial communication RS-485) (Not (Not Blank (Not available) available) available) 1 (1 point) 1 (serial communication RS-485) 2 (2 points) AKT4R111100 1 (serial communication RS-485) AKT4R1111001 2 (2 points) (Note) 1 (multi-input) Model No. Blank (Not available) AKT4R111200 AKT4R1112001 AKT4R112100 AKT4R1121001 AKT4R112200 1 (serial communication RS-485) AKT4R1122001 Note: Using EV2 assigned settings, use for heating and cooling control is possible. Options Please refer to page 15. Product name Terminal cover Model No. AKT4H801 Note: Since a shunt resistor is built in, a separately sold shunt resistor is not required when DC current input is specified. 4 Product name Installation frame For KT4R / KT4H / KT4B Model No. AKW4822 KT SERIES Temperature Controller n KT8R series (Black) Base model Power supply Sensor input Control output 1 (1 point) 2 (2 points) (Note) 1 (1 point) 2 (2 points) (Note) 1 (Relay contact) 1 (100 to 240 V AC) AKT8R Heating / cooling Alarm output 1 (Multi-input) 2 (Non-contact voltage) Heater burnout Model No. AKT8R111100 0 (Not available) 0 (Not available) AKT8R111200 AKT8R112100 AKT8R112200 Note: Using EV2 assigned settings, use for heating and cooling control is possible. Options Please refer to page 15. Product name Product name Model No. AKT8R801 Terminal cover Installation frame Model No. AKW8822 For KT8R Note: S  ince a shunt resistor is built in, a separately sold shunt resistor is not required when DC current input is specified. n KT9R series (Black) Base model Power supply Sensor input Control output Alarm output Heating / cooling Heater burnout AKT9R 1 (100 to 240 V AC) 1 (Multi-input) 1 (Relay contact) 3 (DC current) 1 (1 point) 1 (1 point) 0 (Not available) 0 (Not available) Model No. AKT9R111100 AKT9R113100 Options Please refer to page 15. Product name Model No. AKT9R801 Terminal cover Note: S  ince a shunt resistor is built in, a separately sold shunt resistor is not required when DC current input is specified. n KT7 series (Ash grey) Base model Power supply Sensor input Control output Alarm output Heating / Heater Communication cooling burnout function AKT7 1 2 1 1 2 3 1 0 0 1 2 3 4 Blank 1 Description 22.5 × 75 × 100 mm 0.886 × 2.953 × 3.937 in 100 to 240 V AC 24 V AC / DC Multi-input (Thermocouple, RTD, DC voltage and DC current) Relay contact output 1a 250 V AC 3 A Non-contact voltage output (for SSR drive) DC current Open collector output (alarm output 1) Not available (without heating / cooling function) Not available 5 A (not available for the DC current type) Open collector output 10 A (not available for the DC current type) Open collector output 20 A (not available for the DC current type) Open collector output 50 A (not available for the DC current type) Open collector output Not available Available Notes: 1) CT1 or CT2 for current transformer is provided as an accessory when heater burnout alarm function is added. 2) When adding alarm output 1 and heater burnout alarm at the same time, it'll be common output. Model No. search method Example: When the additional function (heater burnout alarm: 10 A) is added on to the basic function • Model No.: AKT7111102 Options Please refer to page 15. Product name Model No. Shunt resistor (for current input) AKT4811 DIN rail ATA48011 Fastening plate ATA4806 Note: When current input is specified, a shunt resistor (sold separately) is required. 5 KT SERIES Temperature Controller n KT4H series (Ash grey) Base model AKT4H Power supply 1 2 Sensor input Control output 1 1 2 3 Alarm output 1 2 Heating / Heater cooling burnout Communication function 0 0 0 1 2 0 0 0 1 or 2 0 3 1 or 2 0 4 1 or 2 0 5 1 or 2 0 6 Blank 1 2 Description 100 to 240 V AC 24 V AC / DC Multi-input Thermocouple, RTD, DC current and DC voltage Relay contact Non-contact voltage (Voltage output for SSR drive) DC current Heater burnout alarm: not possible 1 point (1a) 2 points (1a + 1a) Heating / cooling control output: not possible Not available Relay contact Heater burnout alarm: not possible Non-contact voltage (Voltage output for SSR drive) Heater burnout alarm: not possible Not available Single phase 20 A (Heater burnout alarm not supported when control output is DC current type / Not supported when heating / cooling control is selected) Single phase 50 A (Heater burnout alarm not supported when control output is DC current type / Not supported when heating / cooling control is selected) Three phase 20 A (Heater burnout alarm not supported when control output is DC current type / Not supported when heating / cooling control is selected) Three phase 50 A (Heater burnout alarm not supported when control output is DC current type / Not supported when heating / cooling control is selected) Not available Serial communication RS485 Contact input Notes: 1) CT1 or CT2 for current transformer is provided as an accessory when heater burnout alarm is added. 2) Under some conditions, option functions (shaded items) may not be available; please check the “Description” of the above table for non-functioning circumstances. Model No. search method Example: When the optional functions (heating / cooling: relay contact, communication function: serial communication) are added on to the basic function • Model No.: AKT4H1111101 n KT4B series (Black) Base model Power supply Sensor input Control output Alarm output Heating / cooling Heater burnout Communication function 1 (1 point) 1 (Relay contact) AKT4B 1 (100 to 240 V AC) Blank (Not available) 2 1 (Non-contact (Multi-input) voltage) 2 (2 points) AKT4B111100 1 AKT4B1111001 (Serial communication) Blank (Not available) 2 (2 points) 1 (1 point) Model No. AKT4B111200 1 AKT4B1112001 (Serial communication) Blank (Not available) AKT4B112100 1 AKT4B1121001 (Serial communication) 0 0 (Not available) (Not available) Blank AKT4B112200 (Not available) 1 AKT4B1122001 (Serial communication) Blank (Not available) 1 (1 point) AKT4B113100 1 AKT4B1131001 (Serial communication) 3 (DC current) Blank (Not available) 2 (2 points) AKT4B113200 1 AKT4B1132001 (Serial communication) Notes: 1) Please inquire if you need specifications not included in the model numbers above. On our website, it is easy to find products by model number selection or by searching for specifications. 2) Use RS485 for serial communication. Options (Common for KT4H and KT4B) Please refer to page 15. Product name Model No. Shunt resistor (for current input) AKT4810 Terminal cover AKT4H801 AKT4H820 Tool cable Installation frame For KT4R / KT4H / KT4B AKW4822 Note: When current input is specified, a shunt resistor (sold separately) is required. 6 Setting software Product name KT Monitor Description Remark Editing of all types of data Available for download free and file saving of charge from our website. Monitoring of indicated value and saving of log files Note: Please download the user manual from our website. KT SERIES Temperature Controller KT Monitor Available for download free of charge from our website. Use it to collect data from the KT4H / KT4B temperature controller. n Features 1. Parameters can be set from a PC. 2. Measurement data can be monitored from a PC. 3. Measurement data can be logged to a PC. All data settings and temperature profile display When free setting software (KT Monitor) and dedicated tool cable are used, you can edit data and so on easily. (Bottom side) Tool cable [Option (sold separately): AKT4H820] Please download the setting software (KT Monitor) from our website. APPLICATIONS Contributing to space saving, cost saving, and effort saving of various heater control systems Injection molding machine Sensor Printing machine Temperature controlled bath Heater SSR KT4H / KT4B Temperature Controller LCD curing oven Kitchen appliance 7 KT SERIES Temperature Controller RATING n Performance outline Item Size Rating power supply (Must be specified) Rating frequency Rating power consumption Input type 5 VA approx. −200 to 1,370 °C (−320 to 2,500 °F) −199.9 to 400.0 °C (−199.9 to 750.0 °F) J −200 to 1,000 °C (−320 to 1,800 °F) R 0 to 1,760 °C (0 to 3,200 °F) S 0 to 1,760 °C (0 to 3,200 °F) B 0 to 1,820 °C (0 to 3,300 °F) E −200 to 800 °C (−320 to 1,500 °F) −199.9 to 400.0 °C T (−199.9 to 750.0 °F) N −200 to 1,300 °C (−320 to 2,300 °F) PL−II 0 to 1,390 °C (0 to 2,500 °F) 0 to 2,315 °C C (W / Re5−26) (0 to 4,200 °F) −200 to 850 °C (−300 to 1,500 °F) Pt100 −199.9 to 850.0 °C (−199.9 to 999.9 °F) −200 to 500 °C (−300 to 900 °F) JPt100 −199.9 to 500.0 °C (−199.9 to 900.0 °F) 4 to 20 mA DC Control output Multi-input DC Voltage Current Rating Rating scale Thermocouple K RTD 0 to 20 mA DC 0 to 1 V DC 0 to 10 V DC 1 to 5 V DC −200 to 1,000 °C (−328 to 1,832 °F) 0 to 1,760 °C (0 to 3,200 °F) 0 to 1,760 °C (0 to 3,200 °F) 0 to 1,820 °C (32 to 3,308 °F) −200 to 800 °C (−328 to 1,472 °F) −200.0 to 400.0 °C (−328.0 to 752.0 °F) −200 to 1,300 °C (−328 to 2,372 °F) 0 to 1,390 °C (32 to 2,534 °F) 6 VA approx. −200 to 1,370 °C (−320 to 2,500 °F) −199.9 to 400.0 °C −200.0 to 400.0 °C (−199.9 to 750.0 °F) (−320.0 to 750.0 °F) −200 to 1,000 °C (−320 to 1,800 °F) 0 to 1,760 °C (0 to 3,200 °F) 0 to 1,760 °C (0 to 3,200 °F) 0 to 1,820 °C (0 to 3,300 °F) −200 to 800 °C (−320 to 1,500 °F) −199.9 to 400.0 °C −200.0 to 400.0 °C (−199.9 to 750.0 °F) (−320.0 to 750.0 °F) −200 to 1,300 °C (−320 to 2,300 °F) 0 to 1,390 °C (0 to 2,500 °F) 0 to 2,315 °C (32 to 4,199 °F) −200 to 850 °C (−328 to 1,562 °F) −200.0 to 850.0 °C (−328.0 to 1,562.0 °F) −200 to 500 °C (−328 to 932 °F) −200 to 500.0 °C (−328.0 to 932.0 °F) 8 VA approx. 0 to 2,315 °C (0 to 4,200 °F) −200 to 850 °C −200 to 850 °C (−300 to 1,500 °F) (−320 to 1,500 °F) −199.9 to 850.0 °C −200.0 to 850.0 °C (−199.9 to 999.9 °F) (−320.0 to 1,500.0 °F) −200 to 500 °C (−300 to 900 °F) −199.9 to 500.0 °C −200.0 to 500.0 °C (−199.9 to 900.0 °F) (−320.0 to 900.0 °F) −1,999 to 9,999 −199.9 to 999.9 −19.99 to 99.99 −1.999 to 9.999 −2,000 to 10,000 −2,000 to 10,000 • Scaling and change to the decimal point position is possible for DC current input and DC voltage input. • DC current input of KT2 / KT7 / KT4H / KT4B is supported with an externally connected 50 Ω shunt resistor (sold separately). K, J, R, S, B, E, T, N, PL-II, C (W / Re5-26) Thermocouple External resistor: Max. 100 Ω (Max. 40 Ω external resistor for B input) RTD Pt100, JPt100 3-conductor system (Allowable input conductor resistance for each conductor: Max. 10 Ω) 0 to 20 mA DC Input impedance: 50 Ω (For KT2 / KT7 / KT4H / KT4B, connect 50 Ω shunt resistor between input terminals.) DC current Allowable input current: Max. 50 mA (For KT2 / KT7 / KT4H / KT4B, when 50 Ω shunt resistor is used) 4 to 20 mA DC 0 to 1 V DC Input impedance: Min. 1 MΩ, Allowable input voltage: Max 5 V, Allowable signal source resistance: Max. 2 kΩ 0 to 5 V DC DC voltage Input impedance: Min. 100 kΩ, 1 to 5 V DC Allowable input voltage: Max 15 V, Allowable signal source resistance: Max. 100 Ω 0 to 10 V DC 1a Relay contact 3 A 250 V AC (at resistive load), 1 A 250 V AC (at inductive load cos ø = 0.4), Electrical life: 100,000 times Non-contact (Must be 12 V DC ±15 % voltage specified) 12+20 V DC, Max. load current: 40 mA (with short circuit protection circuit) Max. load current: 40 mA voltage output ( for SSR drive ) (with short circuit protection circuit) DC current Alarm output 2 (EV2) Control method Target temperature setting Program control function Indication accuracy −1,999 to 9,999 −199.9 to 999.9 −19.99 to 99.99 −1.999 to 9.999 −200.0 to 400.0 °C (−328.0 to 752.0 °F) KT7 KT4H / KT4B 22.5 × 75 mm 48 × 48 mm 0.886 × 2.953 in 1.890 × 1.890 in 100 to 240 V AC 24 V AC / DC 0 to 5 V DC Alarm output 1 (EV1) Thermocouple RTD 4 to 20 mA DC, Load resistance: Max. 550 Ω Relay contact 1a: Control capacity: 3 A 250 V AC (Resistive load), Electrical life: 100,000 times Open collector: Same as Alarm Same as Alarm output 1 Not available Not available 0.1 A 24 V DC output 1 PID action (with auto-tuning function), PI action, PD action (with manual reset function), P action (with manual reset function), ON / OFF action Primary setting / Primary setting / secondary setting / secondary setting ― third setting / fourth (switched by setting (switched by external terminal) external terminal) 1 pattern, 9-step setting is possible (However, make function selection setting of ― either control with fixed set point or program control.) Within ± (0.2 % + 1 digit) of each input span or within ±2 °C (4 °F) whichever is greater However, R or S input; within ±6 °C (12 °F) in the range of 0 to 200 °C (32 to 392 °F) B input, range of 0 to 300 °C (32 to 572 °F): accuracy is not guaranteed. K, J, E, T, and N input, less than 0 °C (32 °F): within ± (0.4 % ±1 digit) of input span Within ± (0.1 % + 1 digit) of each input span or ±1 °C (2 °F) whichever is greater Relay contact 1a 3 A 250 V AC (Resistive load) 1a 1 A 250 V AC (cosø=0.4) Electrical life: 100,000 times DC current and DC voltage Sampling period 8 Specifications KT8R KT9R 48 × 96 mm 96 × 96 mm 1.890 × 3.780 in 3.780 × 3.780 in 100 to 240 V AC ― 50 / 60Hz 8 VA approx. Input range −200 to 1,370 °C (−328 to 2,489 °F) KT2 KT4R 48 × 48 mm 48 × 24 mm 1.890 × 0.945 in 1.890 × 1.890 in 100 to 240 V AC 24 V AC / DC Open collector control capacity: 24 V DC 0.1 A (Max.) Within ± (0.2 % + 1 digit) of each input span 250 ms 125 ms 250 ms KT SERIES Temperature Controller Item Hysteresis (ON / OFF) KT2 Thermocouple and RTD: 0.1 to 100.0 °C (°F) DC current and DC voltage: 1 to 1,000 (The decimal point place follows the selection) Specifications KT8R KT9R KT4R Thermocouple and RTD: 0.1 to 1,000.0 °C (°F) DC current and DC voltage: 1 to 10,000 (The decimal point place follows the selection) Proportional band For sensor input range, DC current and DC voltage: 0.0 to 110.0 % Input without decimal point: 0 to Input span Input with decimal point: 0.0 to Input span DC current and DC voltage: 0.0 to 1,000.0 % Integral time 0 to 1,000 seconds 0 to 3,600 seconds 0 to 300 seconds 0 to 1,800 seconds Derivative time Proportional cycle Allowable voltage fluctuation Insulated resistance Breakdown voltage Malfunction vibration Breakdown vibration Malfunction shock Breakdown shock Ambient temperature Ambient humidity Mass Waterproof Accessories Option functions Display character height Heating / Cooling control Relay contact Non-contact voltage KT7 KT4H / KT4B Thermocouple and RTD: 0.1 to 100.0 °C (°F) DC current and DC voltage: 1 to 1,000 (The decimal point place follows the selection) 0 to 1,000 °C (0 to 2,000 °F) Input with decimal point: 0.0 to 1,000.0 °C (0.0 to 1,000.0 °F) DC current and DC voltage: 0.0 to 100.0 % 0 to 1,000 seconds For sensor input range, DC current and DC voltage: 0.0 to 110.0 % 0 to 300 seconds 1 to 120 seconds When 100 to 240 V AC: 85 to 264 V AC, When 24 V AC / DC: 20 to 28 V AC / DC 500 V DC, Min. 10 MΩ Between input terminal and power terminal Between output terminal and power terminal 1.5 kV AC for 1 min. 10 to 55 Hz (1 cycle/min.), single amplitude: 0.35 mm 0.014 in (10 min. on 3 axes) 10 to 55 Hz (1 cycle/min.), single amplitude: 0.75 mm 0.030 in (1 hour on 3 axes) X, Y and Z each direction for 5 times 98 m/s2 X, Y and Z each direction for 5 times 294 m/s2 0 to 50 °C 32 to 122 °F −10 to 55 °C 14 to 131 °F 0 to 50 °C 32 to 122 °F 35 to 85 % RH (No condensation) 120 g approx. 110 g approx. 160 g approx. 220 g approx. 150 g approx. 120 g approx. IP66 (applicable only to the front panel IP66 (applicable only to the front panel subject to rubber gasket employed) None subject to rubber gasket employed) PV: 8.7 mm 0.342 in SV: 8.7 mm 0.342 in PV: 12.4 mm 0.488 in PV: 14 mm 0.551 in PV: 14 mm 0.551 in PV: 7.4 mm 0.291 in PV: 12 mm 0.472 in (PV / SV switching SV: 8.8 mm 0.346 in SV: 14 mm 0.551 in SV: 14 mm 0.551 in SV: 7.4 mm 0.291 in SV: 6 mm 0.236 in display) 1a Control capacity: Relay contact: Using EV2 assigned setting, use 3 A 250 V AC 1a 3 A 250 V DC for heating and cooling control is None None (at resistive load), (at resistive load) possible. Electrical life: 100,000 times 12 V DC ±15 %, Max. 40 mA ― (with short circuit protection circuit) Heater burnout alarm output Communication function Installation frame / Mounting bracket Terminal cover Rubber gasket Open collector control capacity: 24 V DC 0.1 A (Max.) ― For KT4H only: Specify either single phase 20 A, single phase 50 A, 3 phases 20 A, or 3 phases 50 A for rated heater current. Setting accuracy: within ±5 % of rated heater current Relay contact 1a 3 A 250 V AC (at resistive load), Electrical life: 100,000 times Please refer below to “COMMUNICATION PERFORMANCE OUTLINE”. (Not available with KT8R / KT9R) Included with Included with controller ― controller Sold separately ― Sold separately Included with ― Included with controller controller *Tool port: KT4H and KT4B only; cannot be used simultaneously with serial interface C-MOS level serial communication (option). This port can only be used with the tool cable (AKT4H820). COMMUNICATION PERFORMANCE OUTLINE Item Specifications KT4H / KT4B KT2 / KT7 Communication method Communication speed Select 2400, 4800, 9600 or 19200 bps using key operation. Synchronous method Protocol Coding Modbus (RTU, ASCII), MEWTOCOL (Slave) Binary / ASCII Command resending Error detection Parity check and check sum Interface Number of nodes Maximum communication distance Select 9600, 19200 or 38400 bps using key operation. Asynchronous Modbus (RTU, ASCII) Error correcting Data structure KT4R Half-duplex Start bit: 1 Data bit: 7 Parity: Even parity Stop bit: 1 EIA RS485 compliant Start bit: 1 Data bit: 7, 8 (For Modbus RTU: 8 only) Parity: Even / Odd / None Stop bit: 1 or 2 31 1,000 m 3,280.840 ft (cable resistance must be within 50 Ω) 9 KT SERIES Temperature Controller EXTERNAL CONNECTION DIAGRAM n KT2 series YA (–) 7 8 1 9 NO 3A 250 V AC 2 TC 10 NO 3 SG EV2 11 12 0.1 A 24 V DC 3A 250 V AC 4 5 RELAY B RTD A YB (+) D1 EV1 / OUT2 6 100 to 240 V AC POWER SUPPLY V/A OUT1 DC 5 6 24 V AC / DC POWER SUPPLY n KT4R series PWR 1 PWR 2 EV1 EV2 1 13 2 14 3 15 YA ( ) 4 NO 5 6 RS485 YB ( ) 17 18 SG NO 16 7 O1 >1V A V A V B 8 9 10 11 12 B DC / TC / RTD O1 NO 7 8 KT2 RS485 B • TC: Input terminal for thermocouple • RTD: Input terminal for the resistance temperature detector • DC: Input terminal for DC current or DC voltage For DC current input, connect a separately sold reception resistor (50 Ω) between the input terminals • OUT1: Output terminal for the control output or heating output (option: heating / cooling control) • POWER SUPPLY: Power supply terminal • EV1 / OUT2: Output terminal for event output 1 or cooling output (option: heating / cooling control) • EV2: Output terminal for event output 2 • DI: Input terminal for DI input (There are three types of DI input, SV1 / SV2 external switching function, OUT / OFF (RUN / STOP) external switching function, and timer function.) • RS485: Communication terminal for serial communication. (EV1, EV2: alarm output) • POWER SUPPLY: P  ower supply voltage 100 to 240 V AC or 24 V AC / DC (Ensure correct polarity when using DC in AC / DC 24 V.) • EV1: Event output 1 • EV2: Event output 2 (option) • O1: Control output OUT1 • TC: Thermocouple input • RTD: Resistance temperature detector input • DC: DC voltage input or DC current input • RS485: Serial communication RS485 (option: C5W) n KT8R / KT9R series 1 3 5 7 12 17 19 A V A V NO 18 >1V 9 NO 16 EV2 8 11 15 EV1 6 10 14 O1 4 • POWER SUPPLY: Power supply voltage 100 to 240 V AC • EV1: Event output 1 • EV2: Event output 2 (option) • O1: Control output OUT1 • TC: Thermocouple input • RTD: Resistance temperature detector input • DC: DC voltage input or DC current input 13 PWR 2 B B DC / TC / RTD NO 20 21 22 23 24 n KT7 series POWER SUPPLY 24 V AC / DC 1 2 OUT V/A RELAY POWER SUPPLY 100 to 240 V AC 1 2 3 3A 250 V AC KT7 5 TC RTD A DC 4 0.1 A 24 V DC 6 7 B 8 B 9 EVT No.1 SG No.2 NC No.3 YB (+) No.4 YA (–) No.5 NC No.6 SG n KT4H / KT4B series 10 RS485 No.1 No.6 No.1 No.6 • POWER SUPPLY: Power supply • OUT: Control output • RELAY: Relay contact output • V / A: DC voltage output / DC current output • EVT: Event output [Outputs when alarm, loop fault alarm or heater burnout alarm (option) goes ON.] • TC: Thermocouple • RTD: Resistance temperature detector • DC: DC current or DC voltage • RS485: Serial communication • CT: CT input CT • POWER SUPPLY: Power supply voltage • EVT1: Alarm 1 output • EVT2: Alarm 2 output (option) or heater burnout : Alarm output (option) • OUT1: Control output or heating output (option) • OUT2: Cooling output (option) • TC: Thermocouple input • RTD: Resistance temperature detector input • DC: D  C current input (DCA) or DC voltage input (DCV) (For DC voltage input, + side connection terminal differs depending on the voltage. Also, for DC current input, connect s shunt resistor between No. ⑩ and ⑫ terminals.) • CT1: C  urrent transformer input 1 (option: for single phase and three phases) • CT2: Current transformer input 2 (option: for three phases) • DI: Contact input (option) • RS485: Serial communication RS485 (option) KT SERIES Temperature Controller COMMUNICATION FUNCTION CONNECTION DIAGRAM (PLC Connection Diagram) n KT2 / KT4R series n KT7 series RS485 KT2 KT4R (–) ⑩ YA (–) ⑯ YA (–) (+) ⑪ YB (+) ⑰ YB (+) PLC ⑫ COM ⑱ COM Shielded cable No.0 PLC (–) ④ (+) ③ KT7 No.1 No.30 Communication cable KT2 KT4R ⑩ YA (–) ⑯ YA (–) ⑪ YB (+) ⑰ YB (+) ⑫ COM ⑱ COM Terminal No. ③ to YB (+) Terminal No. ④ to YA (–) Notes: 1) Terminating resistors (Terminators) The KT series has a built-in pull-up resistor or pull-down resistor, which serves as the terminating resistor. For this reason, do not connect the terminating resistor on the communication line. 2) Please use a RJ-11 6 polarized type modular connector. Please use a cable that is suitable for a modular connector. (Only KT7 series) n KT4H / KT4B series PLC RS485 KT4H (−) ⑯ YA (–) (+) ⑰ YB (+) ⑱ COM Shielded cable KT4H ⑯ YA (–) ⑰ YB (+) Notes: 1) Shielded cable To prevent current flow along shield sections, ground one end of the shield cable. (If both ends of the shield section are grounded, a closed circuit with the earth will form and electricity flowing through the shield cable will cause increased susceptibility to noise.) 2) Terminating Resistors (Terminators) The KT4H / KT4B series has a built-in pull-up resistor or pull-down resistor. For this reason, do not connect the terminating resistor on the communication line. ⑱ COM INSTALLATION n KT2 series Please install vertically in order to satisfy the IP66 specification for dust and splash proofing. The possible control panel plate thickness for installation is between 1 to 10 mm 0.394 in. (1) Insert the unit from the front of the control panel. (2) Insert the installation frame until that the two edges make contact with the panel. (3) Tighten the screw and then turn it 3/4 of a turn after the edge of the screw reaches the panel. n KT4R series Please install to a rigid, irregularity-free flat surface in order to satisfy the IP66 specification for dust and splash proofing. Panel thickness for installation: 1 to 5 mm 0.039 to 0.197 in. (1) Insert the unit from the front of the control panel. (2) Insert the installation frame until that the edges make contact with the panel and tighten the screw. Fix by rotating screws one full turn after contact of screw tip and panel. Apply tightening torque of 0.15 N•m. Rubber gasket Installation frame 11 KT SERIES Temperature Controller INSTALLATION n KT8R / KT9R series Please install to a rigid, irregularity-free flat surface in order to satisfy the IP66 specification for dust and splash proofing. Panel thickness for installation: 1 to 7 mm 0.039 to 0.276 in. (1) Insert the controller from the front of the control panel. (2) Attach the screw type mounting brackets by the holes at the top and bottom of the case and secure the controller in place with the screws. Apply tightening torque of 0.1 N•m. Rubber gasket Screw type mounting bracket n KT7 series • DIN rail mounting (1) Hook ① of the KT7 series controller on the upper side of the DIN rail. (2) Making the ① part of the KT7 series controller as a support, fit the lower part of the KT7 series controller to the DIN rail. KT7 series controller will be completely fixed to the DIN rail with a “click” sound. Recommended DIN rail: Model No. ATA48011 Recommended fastening plate: Model No. ATA4806 ① DIN rail ■■ ■■ ■■ pv ■■ av T G/ T EV AT ■■ DE ■■ B T/ MO ■■ G/ TE pv VT T KT7 /B AT Fastening plate av 警告 ケースは樹脂製ですので、取付金具 のねじを必要以上に締め過ぎると、 取付金具やケースが変形するおそれ があります。 0.12N・mぐらいで締めてください。 MO DE 5 6 7 8 ② 9 n KT4H / KT4B series Please install vertically in order to satisfy the IP66 specification for dust and splash proofing. The possible control panel plate thickness for installation is between 1 to 5 mm 0.039 to 0.197 in. (1) Insert the unit from the front of the control panel. (2) Push the installation frame fully into contact with the panel and tighten the screws. (Screw tightening torque: 0.05 N•m to 0.06 N•m) Rubber gasket 12 KT SERIES Temperature Controller DIMENSIONS (Unit: mm in) n KT2 series Panel cutout M3 +0.6 0 45 +0.024 1.772 0 47.6 1.874 Rubber gasket PV SV AT T/R OUT EV1 EV2 MODE OUT OFF 48 1.890 22.2 0 +0.012 0.874 0 Installation frame 36.5 1.437 MEMO/STEP +0.3 44.8 1.764 24 0.945 KT2 10.6 0.417 Min. 40 Min. 1.575 Min. 60 Min. 2.362 21.6 .850 98.5 3.878 Tolerance: ±1 ±0.039 Note: The communications terminal is the screw terminal on the back of the controller. n KT4R series Panel cutout Rubber gasket Installation frame Terminal cover (Sold separately) Min. 75 Min. 2.953 Min. 75 Min. 2.953 45 +0.5 –0 1.772 +0.020 –0 +0.5 45 –0 1.772 +0.020 –0 n × 48-3 +0.5 –0 n × 1.890-3 +0.020 –0 44.5 (47.5) (*) (60) 1.752 (1.870) (2.362) 45 +0.5 –0 1.772 +0.020 –0 48 1.890 8.4 0.331 (*) Dimensions when terminal cover is fitted. 58.8 2.315 (65) (*) (2.559) Lateral close mounting n: Number of controllers mounted Tolerance: ±1 ±0.039 Note: The communications terminal is the screw terminal on the back of the controller. 13 KT SERIES Temperature Controller DIMENSIONS (Unit: mm in) n KT8R series External dimension Panel cutout Min. 75 Min. 2.953 Screw type mounting bracket Terminal cover (Sold separately) Rubber gasket 92 +0.5 –0 3.622 +0.020 –0 Min. 130 Min. 5.118 96 3.780 n × 48-3 +0.5 –0 n × 1.890-3 +0.020 –0 □91 (94) (*) (106) □3.583 (3.701) (4.173) 92 +0.5 –0 +0.020 3.622–0 Lateral close mounting n: Number of controllers mounted 45 +0.5 –0 1.772 +0.020 –0 48 1.890 Tolerance: ±1 ±0.039 58.8 2.315 (67) (*) (2.638) 8.4 0.331 (*) Dimensions when terminal cover is fitted. n KT9R series External dimension Panel cutout Screw type mounting bracket Terminal cover (Sold separately) Rubber gasket □91 (94) (*) (106) □3.583 (3.701) (4.173) Min. 130 Min. 5.118 92 +0.8 –0 +0.031 3.622 –0 n × 96-3 +0.5 –0 n × 3.780-3 +0.020 –0 Min. 130 Min. 5.118 Lateral close mounting n: Number of controllers mounted □92 +0.5 –0 +0.020 □3.622 –0 58.8 2.315 (67) (*) (2.638) 8.4 0.331 □96 □3.780 (*) Dimensions when terminal cover is fitted. Tolerance: ±1 ±0.039 n KT7 series M3 1 2 3 4 OUT EVT T/R AT External dimension PV SV 75 2.953 MODE KT7 5 6 7 8 9 22.5 0.886 97 3.819 100 3.937 M2 Tolerance: ±1 ±0.039 Note: The communications terminal is the modular jack on the bottom side of the controller. n KT4H / KT4B series Panel cutout External dimension Rubber gasket 1.5 0.059 Installation frame Terminal cover (Sold separately) When installing in series Min. 75 Min. 2.953 +0.5 45 0 +0.020 1.772 0 M3 screw +0.5 Min. 75 Min. 2.953 n × 48-3 0 +0.020 n × 1.890-3 0 44.5 47.5 59.2 1.752 1.870 2.331 +0.5 45 0 +0.020 1.772 0 45 1.772 □48 □1.890 14 6 0.236 56.0 2.205 61.0 2.402 Lateral close mounting n: Number of controllers mounted +0.5 0 +0.020 0 Tolerance: ±1 ±0.039 Note: If longitudinal or lateral close mounting is used for the controller, IP66 specification (Dust-proof/Drip-proof) may be compromised, and all warranties will be invalidated. KT SERIES Temperature Controller OPTIONS n Terminal cover AKT2801 (for KT2) AKT4H801 (for KT4H / KT4B / KT4R) AKT8R801 (for KT8R) AKT9R801 (for KT9R) 47.5 1.870 23.8 0.937 94 3.701 3.5 0.138 44.5 1.752 47.5 1.870 15.5 0.610 >PC< 8 0.315 20 0.787 45.8 1.803 17 0.669 46.5 1.831 12 0.472 2 pieces of terminal cover of AKT8R801 can be used as an AKT9R801. n Current transformer (CT) • CT1 (for 5, 10 and 20 A) l ø5.8 ø0.228 15 k 0.591 n Tool cable (for KT4H / KT4B) External dimension AKT4H820 • CT2 (for 50 A) l 7.5 0.295 0.5 0.020 2.8 0.110 K 30 1.181 k n2.5 Plug 3-Pole type 200±20 7.874±0.787 100 3.937 L 50 1.969 25 0.984 10.5 0.413 20 0.787 USB Plug 35 1.378 2000±40 78.74±1.575 n Shunt resistor 21 0.827 40 1.575 3 0.118 40 1.575 10 0.394 ø12 ø0.472 40 1.575 30 1.181 2-ø3.5 2-ø0.138 30 1.181 AKT4810 (for KT2 / KT4H / KT4B) 74 ±6 2.913 ±0.236 15 0.591 2-M3 Note: Current transformer CT1 or CT2 is included (only with KT7 and KT4H) when heater burnout alarm function is added. AKT4811 (for KT7) n Installation AKW4822 (for KT4R / KT4H / KT4B) frame 5 70 2.756 2 × R2 R0.079 0.197 24 0.945 40 1.575 12.2 0.480 4.2 0.165 ±0.2 12.2 0.480 30 1.181 R2 9 19 14.2 R2 × 2 .07 0.748 0.559 2 × 79 .0 4.2 R0 R0 0.165 (R ) 9 R2 0.07 R 4.2 0.165 1.6 +0.024 R 2 9 0.063 45 +0.6 -0 1.772 -0 2 × . 07 0 R 45 +0.6 -0 1.772+0.024 -0 92+0.4 125 0 4.921 3.622+0.016 0 R 2 0. 0 R 26 ±1 1.024 ±0.039 110±0.2 4.331±0.008 79 80 3.150 16.5 0.650 +0.016 45 +0.4 0 1.772 0 75 2.953 Product name For KT2 Model No. AKT2801 For KT4R Shunt resistor (for current input) (Note 1) 1.6 0.063 ±0.008 62 2.441 .1) .1) R2 (R 2 ( 80 3.150 Terminal cover AKW8822 (for KT8R) For KT8R For KT9R For KT4H / KT4B For KT2 / KT4H / KT4B For KT7 AKT4H801 AKT8R801 AKT9R801 AKT4H801 AKT4810 AKT4811 Product name Current transformer CT1 (for 5, 10 and 20 A) (CT) (Note 2) CT2 (for 50 A) Current transformer CT1 or CT2 is included when heater burnout alarm function is added. Model No. Tool cable (for KT4H / KT4B) For KT4R / KT4H / KT4B Installation frame For KT8R DIN rail For KT7 Fastening plate For KT7 AKT4H820 AKW4822 AKW8822 ATA48011 ATA4806 Notes: 1) For KT2, KT4H, KT4B and KT7, when current input is specified, the shunt resistor (sold separately) is required. 2) Current transformer CT1 or CT2 is included (only with KT7 and KT4H) when heater burnout alarm function is added. EN / IEC STANDARD Model name EMC Directive Low Voltage Directive KT2 / KT4R / KT4H / KT4B / KT7 / KT8R / KT9R EN 61000-6-4 / EN 61000-6-2 EN 61010-1 / IEC 61010-1 FOREIGN STANDARD Model name KT2 / KT4R / KT4H / KT4B / KT7 / KT8R / KT9R UL (Recognized) File No. Standard No. E197456 UL873 UL (Listed) File No. Standard No. - CSA (Certified) File No. Standard No. E197456 (C-UL) C22, 2 No. 24-93 15 KT SERIES Temperature Controller NOTES FOR USE n Notes on site selection This controller is intended to be used in the following environment (IEC 61010-1) •O  vervoltage category II and Pollution degree 2 Mount the controller in a place with: • A minimum of dust, and an absence of corrosive gases • No flammable, explosive gases •F  ew mechanical vibrations or shocks • No exposure to direct sunlight, an ambient temperature of 0 to 50 °C 32 to 122 °F (For KT4R / KT8R / KT9R: -10 to 55 °C 14 to 131 °F) that does not change rapidly. (When installing inside a panel, make particular allowance for heat dissipation. Avoid installation in situations such as above equipment that generates heat.) •L  ocations in which temperature rapidly changes may cause condensation. •L  ocations or atmospheres in which benzine, thinners, alcohol, or other organic solvents are present, or in which ammonia, sodium hydroxide, or other strong alkaline substances may adhere. • Locations susceptible to direct impact or the transmission of vibrations, or where splashing with water is possible. • In the proximity of equipment in which large switching surges occur or near high-voltage cables, high-voltage equipment, power lines, power equipment, ham radio transmitters, or equipment containing these or similar devices. • An ambient non-condensing humidity of 35 to 85 % RH • No large capacity electromagnetic switches or cables through which large current is flowing • No water, oil or chemicals or where the vapors of these substances can come into direct contact with the controller n Notes on wiring • The terminal block of KT4R / KT8R / KT9R / KT4H / KT4B series are designed to be wired from the left side (The terminal of KT2 series are designed to be wired from the upper and lower direction). The lead wire must be inserted from the left side of the terminal, and fastened by the terminal screw. Use a wirepressed terminal with insulation sleeve that fits to the M3 screw. • In the case of 24 V AC / DC power supply, do not confuse the polarity when it is DC. •W  ith the relay contact output type, use the relay externally according to the capacity of the load to protect the built-in relay contact. •W  hen wiring, keep input wire (Thermocouple, RTD, etc.) away from power source wire and load wire. •T  urn the power supply to the instrument off before wiring or checking. Working or touching the terminal with the power switched on may result in electric shock which could cause severe injury or death. •D  o not drop wire chips into the holes of vent when wiring. •T  o prevent the controller from harmful effects of unexpected high level noise, it is recommended that a surge absorber be installed between the electromagnetic switch coils. n Notes on mounting • Do not use excessive force while screwing in the installation frame and mounting bracket of KT4R / KT8R / KT9R / KT4H / KT4B series. For KT8R / KT9R series, recommended torque is approximately 0.1 N·m. For KT4H / KT4B series, recommended torque is approximately 0.05 to 0.06 N·m. For KT4R series, recommended torque is approximately 0.15 N·m. • When mounting the KT7 series to the DIN rail, mount it in a lateral direction. Make sure a click is audible when fixed into place. nO  ptional heater burnout alarm output (for KT7 / KT4H series) • This alarm output is not available for detecting heater current under phase control. • Use the current transformer (CT) provided, and pass one lead wire of the heater circuit into the hole of CT. • When wiring, keep CT wire away from power source wire and load wire to avoid external interference. • In three phase installations for KT4H series, ensure that R, S and T are each connected to a 2-line CT that connects with CT1 [⑬ - ⑭] and CT2 [⑭ - ⑮] terminals. CT input terminals Wire-pressed terminal Max. 5.8 mm Max. 0.228 in Round type Type name NICHIFU Co., Ltd. 1.25Y-3 J.S.T. Mfg. Co., Ltd. VD1.25-B3A 0.6 N•m Max. 1.0 N•m. NICHIFU Co., Ltd. 1.25-3 J.S.T. Mfg. Co., Ltd. V1.25-3 ø3.2 mm ø0.126 in Max. 5.8 mm Max. 0.228 in Fork type Company name Fastening torque 3.2 mm 0.126 in • Terminal screw fastening torque is 0.6 N·m to 1.0 N·m (for KT4R / KT8R / KT9R / KT4H / KT4B series). For KT7 series by M3 screw is less than 0.5 N·m and by M2 screw is less than 0.25 N·m respectively. • Use a thermocouple and compensating lead wire according to the sensor input specification of the controller. • Use a 3-wire system of RTD according to the sensor input specification of the controller. • This controller has no built-in power switch, circuit breaker and fuse. Therefore, it is necessary to install them in the circuit near the external controller. (Recommended fuse: Time-lag fuse, rating voltage 250 V AC, rating current 2 A) 2015.07 Power supply CT panasonic.net/id/pidsx/global Heater nP  lease use rod terminals for the terminal portion of the KT7 series. We recommend terminals made by Phoenix Contact. ① to ④ are AI0.25-8YE, AI0.34-8TQ, AI0.5-8WH, AI0.75-8GY, AI1.08RD, and AI1.5-8BK. ⑤ to ⑨ are AI0.25-8YE, AI0.34-8TQ, and AI0.5-8WH. The screw tightening torque for ① to ④ should be less than 0.5 N·m and for ⑤ to ⑨ it should be less than 0.25 N·m. Make sure no screw is loose. Panasonic Industrial Devices SUNX Co., Ltd. Global Sales Department No. CE-KT-2-7 July, 2015 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan ■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591 All Rights Reserved ©Panasonic Industrial Devices SUNX Co., Ltd. 2015
AKT4R111200 价格&库存

很抱歉,暂时无法提供与“AKT4R111200”相匹配的价格&库存,您可以联系我们找货

免费人工找货
AKT4R111200
    •  国内价格
    • 1+1710.96891

    库存:1