Temperature Controller
KT SERIES
Conforming to
EMC Directive
Recognition
Upgraded KT4, KT8 and KT9 models
Improved visibility, operability and performance!
Upgraded
Upgraded
Upgraded
KT4R series
KT8R series
KT9R series
[48 × 48 × 58.8 m
mm]
[1.890 × 1.890 × 2.315 in]
[48 × 96 × 58.8 m
mm]
[1.890 × 3.780 × 2.315 in]
[96 × 96 × 58.8 m
mm]
[3.780 × 3.780 × 2.315 in]
KT4H
KT2 series
KT7 series
[48 × 24 × 98.5 mm]
[1.890 × 0.945 × 3.878 in]
[22.5 × 75 × 100 mm]
[0.886 × 2.953 × 3.937 in]
KT4H / KT4B
series
[48 × 48 × 56 mm]
[1.890 × 1.890 × 2.205 in]
KT4B
Extensive line-up with models to match
application and space
2015.07
panasonic.net/id/pidsx/global
Upgraded models
Features of KT4R, KT8R and KT9R
Smooth initial setting and setting adjustment
Fine control of heat capacity
Operation startup can begin after using initial setting mode to enter
the control values required before first use, and after entering values
for items such as frequently used and frequently changed settings.
Smooth operation is enabled at initial startup and after changing
settings.
Sampling period rate half (1/2 times) from previous model: high speed
125 ms processing implemented. With twice the responsiveness, it
is possible to more finely carry out control, for example, of the heat
capacity.
Built-in easy programming function
Built-in rearing auto tuning function
Easy programmed control made possible using nine-step setting
procedure. By entering specific target values for each indicated period,
freely selectable temperature control is possible.
The built-in rearing auto tuning function uses the step response
method. From temperature rise behavior alone, it can calculate the PID
constants. It is possible to calculate constants, even when auto tuning
cannot be used to generate them.
Because an ON / OFF operation is unnecessary, there is no disruption
in control.
Example: From start of programmed control
Perform control so it becomes 200 °C 392 °F after 1 hour.
°F until1after 2 hours
Maintain 200 °C 392
3
2
5
Step
4
Perform control so it becomes 300 °C 572 °F after 30 minutes.
( )
200
392
SV °C
°F
Step
( )
SV °C
°F
Time
( )
Wait °C
°F
300 °C
572 °F
1
Time
2
1:00
3
300
200
200
392Wait °C 392 10 572
°F
50
2:00
1:00
0:30
300 °C
10 572 °F 0
10
32
50
50
( )
200
392
4
2:00
300
0
572
32
1:00
0
32
300
572
300
572
5
1:00
0
10 32 0
32
50
2:00
0:30
Temperature
SV value
0
32
2:00
0
32
Temperature
SV value
0
32
200 °C
392 °F
200 °C
392 °F
0 °C
32 °F
0 °C
32 °F
Time
Rearing AT start point
Control parameter
measuring
Rearing AT start point
Calculation of PID Control with calculated
constants
PID constants
Time
Calculation of PID Control with calculated
constants
PID constants
Other features
Control parameter
measuring
•V
isibility and operability improved with large display and key size.
• Unit 60 mm 2.362 in approx. long: compact design saves space.
• With DC current output, can be used as simple signal converter.
Shared features of KT series
Multi-input sensors
Versatile thermocouple, RTD, DC voltage and DC current input for
temperature detecting sensors
Simple operation enables highly accurate temperature control
All required operations can be enabled by the front keys and highly
accurate PID control mode ensures an input span of ±0.2 %.
DIN Rail mounting types are aligned taking global
market demand into consideration (for KT7 series)
Improved visibility and ease of operation
More compact than before
The KT4H / KT4B series features improved visibility with a process
value (PV) character height of 12 mm 0.472 in and an 11-segment
display. Connectable to a PC, it offers a full range of control and
communication functions.
Communication specification uses RS485 (Modbus protocol)
(Sample System Configuration)
FPΣ Programmable Controller
The KT7 series is equipped with DIN rail mounting complying to DIN
standards. Furthermore, because its control panel is compact, the KT7
series saves space.
Nine step pattern control possible. (for KT2 series)
RS485
For KT2 series, despite DIN 48 x 24 size, selection is possible of
control with fixed set point and nine step pattern control.
Meets market demands for cost-effectiveness
The KT series offers both economy and high performance.
The KT series complies with UL/c-UL standard and CE marking.
2
Up to 31 units can be connected
*1 Only on type equipped with communications function.
*2 In the configuration above, the FPΣ requires a communication cassette (FPG-COM3).
*3 Modbus protocol is a communication protocol developed for PLCs by Modicon Inc.
KT SERIES Temperature Controller
PARTS AND FUNCTIONS
n KT2 series
3
4
5
① PV / SV display (red) �������������������Indicates the process value (PV) and setting value (SV).
During setting mode, characters and setting value of the setting item are indicated in turn.
② MEMO / STEP display (green) ����Indicates the memory number during fixed value control. Indicates step number during
program control.
③ PV indicator (red) ������������������������Lights up when the input value is indicated.
④ SV indicator (green) ��������������������Lights up when main setting value is indicated.
⑤ AT indicator (yellow) ��������������������Flashes during auto-tuning (AT)
⑥ T / R indicator (yellow) ����������������Flashes during serial communication (Lit while sending data, Unlit while receiving data)
⑦ OUT indicator (green) �����������������Lights up when control output or OUT1 (heating side) output (option: heating / cooling control) is ON.
For DC current output type, it flashes corresponding to the manipulated variable in a 0.25
second cycle
⑧ EV1 indicator (red) ����������������������Lights up when event output 1 or OUT2 (cooling side) output (option: heating / cooling
control) is ON.
⑨ EV2 indicator (red) ����������������������Lights up when event output 2 is ON.
⑩ Increase key ��������������������������������Increases the numeric value.
⑪ Decrease key ������������������������������Decreases the numeric value.
⑫ Mode key �������������������������������������Selects the setting mode or registers the setting value.
By pressing the mode key, the setting value or selected value can be registered
⑬ OUT / OFF key ����������������������������The control output OUT / OFF or program control RUN / STOP can be switched.
6
7
1
8
2
9
10
11
12
13
n KT4R series
n KT8R series
1
1
8
2
7
2
5
6
8
3
4
3
n KT9R series
5
1
4
6
n KT7 series
7
1
8
① PV display ����������������������� Indicates the process value
(PV).
② SV display ����������������������� Indicates the setting value
(SV)
③ Increase key ������������������� Increases the numeric value
④ Decrease key ����������������� Decreases the numeric
value
⑤ Mode key ������������������������ Selects the setting mode or
registers the setting value.
⑥ OUT / OFF key ��������������� The control output ON /
OFF, auto / manual control
function or program control
can be switched. (Not available in KT7 series)
⑦ STEP / MEMO display ��� Indicates the step number
(program control) and set
value memory number (for
KT8R and KT9R)
⑧ Action indicators (Not available in KT7 series)
•O1 ������Lights up when control output 1 is ON.
Lights up when heating control output
(option) is ON.
For DC power output type, it flashes corresponding to the manipulated variable in a 125
ms cycle
•O2 ������Lights up when cooling control output (option)
is ON.
•EV1 ����Lights when Alarm 1 output is ON.
•EV2 ���Lights when Alarm 2 output (option) is ON.
•AT ������Flashes during auto-tuning or auto-reset
•T/R �����Lights during serial communication (option)
TX output. (for KT4R only)
2
2
5
3
6
3
4
5
4
Note 1: Color selection is the same for each size.
n KT4H / KT4B series
①
②
③
④
⑤
⑦
⑥
⑧
⑨
(Bottom side)
① Action indicators (backlight: orange)
°F °C �������������������Lights respectively when temperature unit °F / °C is selected
T / R ���������������������Lights during serial communication (option) TX output.
AT ������������������������Flashes during auto-tuning or auto-reset
OUT1 �������������������Lights when control output is ON or heating output (option) is
ON.
For DC current output type, it flashes corresponding to the
manipulated variable in 0.25 second cycles.
OUT2 �������������������Lights when cooling output (option) is ON.
EVT1 �������������������Lights when alarm 1 output is ON.
EVT2 �������������������Lights when alarm 2 output (option) is ON or heater burnout
alarm output (option) is ON.
LOCK �������������������Lights when lock 1, lock 2 or lock 3 is selected.
② MEMO display ����Indicates the set value memory number. (backlight: green)
③ PV display �����������Indicates the process value (PV). (backlight: red / orange /
green)
④ SV display �����������Indicates the set value (SV). (backlight: green)
⑤ Mode key ������������Selects the setting mode and registers the set value.
⑥ OUT / OFF key ���The control output ON / OFF or auto / manual control function can be switched.
⑦ Increase key �������Increases the numeric value
⑧ Decrease key �����Decreases the numeric value
⑨ Tool connector ����By connecting the dedicated cable, the following operations
can be conducted from the external computer.
• Reading and setting of SV, PID and various set values
• Reading of PV and action status
• Function change
3
KT SERIES Temperature Controller
PRODUCT TYPES
n KT2 series (Ash grey)
Base
model
AKT2
Power
supply
Sensor
input
1
2
Control
output
1
Alarm
output
Heating / Heater Communication
cooling burnout
function
1
2
3
2
0
0
Blank
1
1
0
Blank
1
0
0
1
0
1
0
1
Description
48 × 24 × 98.5 mm 1.890 × 0.945 × 3.878 in
100 to 240 V AC
Must be
specified
24 V AC / DC
Multi-input (Thermocouple, RTD, DC voltage and DC current)
Relay contact output 1a 250 V AC 3 A
Must be
Non-contact voltage output (for SSR drive)
specified
DC current
When both heating / cooling and communication functions are not added
Relay contact output (alarm 1) ...... Can be used
Open collector output (alarm 2) ...... Can be used
When only heating / cooling function is added
Relay contact output (alarm 1) ...... Cannot be used
Open collector output (alarm 2) ...... Can be used
When only communication function is added
Relay contact output (alarm 1) ...... Can be used
Open collector output (alarm 2) ...... Cannot be used
When both heating / cooling and communication functions are added
Relay contact output (alarm 1) ...... Cannot be used
Open collector output (alarm 2) ...... Cannot be used
Notes: 1) When heating / cooling is selected, alarm output 1 cannot be used.
2) When the communication function is selected, alarm output 2 cannot be used.
Model No. search method
Example: Basic functions + optional functions (Heating / cooling: relay contact output + communication function)
• For KT2 series, the option function is only the following 4 patterns.
AKT21200 Blank AKT211001
AKT21110 Blank AKT210101
• Model No.: AKT21110101
Options Please refer to page 15.
Product name
Model No.
Shunt resistor (for current input)
AKT4810
Terminal cover
AKT2801
Note: When current input is specified, a shunt resistor (sold separately) is required.
n KT4R series (Black)
Base
model
Power supply Sensor input
Alarm
output
Control output
1
(1 point)
1
(Relay contact)
AKT4R
1
(100 to 240
V AC)
Heating /
cooling
Heater
burnout
Communication function
Blank (Not available)
2
(Non-contact voltage)
Blank (Not available)
0
0
1 (serial communication RS-485)
(Not
(Not
Blank (Not available)
available) available)
1
(1 point)
1 (serial communication RS-485)
2
(2 points)
AKT4R111100
1 (serial communication RS-485) AKT4R1111001
2
(2 points)
(Note)
1
(multi-input)
Model No.
Blank (Not available)
AKT4R111200
AKT4R1112001
AKT4R112100
AKT4R1121001
AKT4R112200
1 (serial communication RS-485) AKT4R1122001
Note: Using EV2 assigned settings, use for heating and cooling control is possible.
Options Please refer to page 15.
Product name
Terminal cover
Model No.
AKT4H801
Note: Since a shunt resistor is built in, a separately sold shunt resistor is not required when
DC current input is specified.
4
Product name
Installation frame
For KT4R / KT4H / KT4B
Model No.
AKW4822
KT SERIES Temperature Controller
n KT8R series (Black)
Base model
Power supply
Sensor input
Control output
1
(1 point)
2
(2 points) (Note)
1
(1 point)
2
(2 points) (Note)
1
(Relay contact)
1
(100 to 240 V AC)
AKT8R
Heating /
cooling
Alarm output
1
(Multi-input)
2
(Non-contact voltage)
Heater
burnout
Model No.
AKT8R111100
0
(Not
available)
0
(Not
available)
AKT8R111200
AKT8R112100
AKT8R112200
Note: Using EV2 assigned settings, use for heating and cooling control is possible.
Options Please refer to page 15.
Product name
Product name
Model No.
AKT8R801
Terminal cover
Installation frame
Model No.
AKW8822
For KT8R
Note: S
ince a shunt resistor is built in, a separately sold shunt resistor is not required when
DC current input is specified.
n KT9R series (Black)
Base model
Power supply
Sensor input
Control output
Alarm output
Heating /
cooling
Heater
burnout
AKT9R
1
(100 to 240 V AC)
1
(Multi-input)
1
(Relay contact)
3
(DC current)
1
(1 point)
1
(1 point)
0
(Not
available)
0
(Not
available)
Model No.
AKT9R111100
AKT9R113100
Options Please refer to page 15.
Product name
Model No.
AKT9R801
Terminal cover
Note: S
ince a shunt resistor is built in, a separately sold shunt resistor is not required when
DC current input is specified.
n KT7 series (Ash grey)
Base
model
Power
supply
Sensor
input
Control
output
Alarm
output
Heating / Heater Communication
cooling burnout
function
AKT7
1
2
1
1
2
3
1
0
0
1
2
3
4
Blank
1
Description
22.5 × 75 × 100 mm 0.886 × 2.953 × 3.937 in
100 to 240 V AC
24 V AC / DC
Multi-input (Thermocouple, RTD, DC voltage and DC current)
Relay contact output 1a 250 V AC 3 A
Non-contact voltage output (for SSR drive)
DC current
Open collector output (alarm output 1)
Not available (without heating / cooling function)
Not available
5 A (not available for the DC current type) Open collector output
10 A (not available for the DC current type) Open collector output
20 A (not available for the DC current type) Open collector output
50 A (not available for the DC current type) Open collector output
Not available
Available
Notes: 1) CT1 or CT2 for current transformer is provided as an accessory when heater burnout alarm function is added.
2) When adding alarm output 1 and heater burnout alarm at the same time, it'll be common output.
Model No. search method
Example: When the additional function (heater burnout alarm: 10 A) is added on to the basic function
• Model No.: AKT7111102
Options Please refer to page 15.
Product name
Model No.
Shunt resistor (for current input)
AKT4811
DIN rail
ATA48011
Fastening plate
ATA4806
Note: When current input is specified, a shunt resistor (sold separately) is required.
5
KT SERIES Temperature Controller
n KT4H series (Ash grey)
Base
model
AKT4H
Power
supply
1
2
Sensor
input
Control
output
1
1
2
3
Alarm
output
1
2
Heating / Heater
cooling burnout
Communication
function
0
0
0
1
2
0
0
0
1 or 2
0
3
1 or 2
0
4
1 or 2
0
5
1 or 2
0
6
Blank
1
2
Description
100 to 240 V AC
24 V AC / DC
Multi-input Thermocouple, RTD, DC current and DC voltage
Relay contact
Non-contact voltage (Voltage output for SSR drive)
DC current
Heater burnout alarm: not possible
1 point (1a)
2 points (1a + 1a)
Heating / cooling control output: not possible
Not available
Relay contact
Heater burnout alarm: not possible
Non-contact voltage (Voltage output for SSR drive) Heater burnout alarm: not possible
Not available
Single phase 20 A (Heater burnout alarm not supported when control output is
DC current type / Not supported when heating / cooling control is selected)
Single phase 50 A (Heater burnout alarm not supported when control output is
DC current type / Not supported when heating / cooling control is selected)
Three phase 20 A (Heater burnout alarm not supported when control output is
DC current type / Not supported when heating / cooling control is selected)
Three phase 50 A (Heater burnout alarm not supported when control output is
DC current type / Not supported when heating / cooling control is selected)
Not available
Serial communication RS485
Contact input
Notes: 1) CT1 or CT2 for current transformer is provided as an accessory when heater burnout alarm is added.
2) Under some conditions, option functions (shaded items) may not be available; please check the “Description” of the above table for non-functioning circumstances.
Model No. search method
Example: When the optional functions (heating / cooling: relay contact, communication function: serial communication) are added on to the basic function
• Model No.: AKT4H1111101
n KT4B series (Black)
Base model
Power supply
Sensor input Control output Alarm output Heating / cooling Heater burnout Communication function
1
(1 point)
1
(Relay
contact)
AKT4B
1
(100 to 240 V AC)
Blank
(Not available)
2
1
(Non-contact
(Multi-input)
voltage)
2
(2 points)
AKT4B111100
1
AKT4B1111001
(Serial communication)
Blank
(Not available)
2
(2 points)
1
(1 point)
Model No.
AKT4B111200
1
AKT4B1112001
(Serial communication)
Blank
(Not available)
AKT4B112100
1
AKT4B1121001
(Serial communication)
0
0
(Not available) (Not available)
Blank
AKT4B112200
(Not available)
1
AKT4B1122001
(Serial communication)
Blank
(Not available)
1
(1 point)
AKT4B113100
1
AKT4B1131001
(Serial communication)
3
(DC current)
Blank
(Not available)
2
(2 points)
AKT4B113200
1
AKT4B1132001
(Serial communication)
Notes: 1) Please inquire if you need specifications not included in the model numbers above. On our website, it is easy to find products by model number selection or by searching for specifications.
2) Use RS485 for serial communication.
Options (Common for KT4H and KT4B) Please refer to page 15.
Product name
Model No.
Shunt resistor (for current input)
AKT4810
Terminal cover
AKT4H801
AKT4H820
Tool cable
Installation frame
For KT4R / KT4H / KT4B
AKW4822
Note: When current input is specified, a shunt resistor (sold separately) is required.
6
Setting software
Product name
KT Monitor
Description
Remark
Editing of all types of data
Available for download free
and file saving
of charge from our website.
Monitoring of indicated
value and saving of log files
Note: Please download the user manual from our website.
KT SERIES Temperature Controller
KT Monitor
Available for download free of charge from our website. Use it to collect data from the KT4H / KT4B temperature controller.
n Features
1. Parameters can be set from a PC.
2. Measurement data can be monitored from a PC.
3. Measurement data can be logged to a PC.
All data settings and temperature profile display
When free setting software (KT Monitor) and dedicated
tool cable are used, you can edit data and so on easily.
(Bottom side)
Tool cable
[Option (sold separately): AKT4H820]
Please download the setting software (KT Monitor) from our website.
APPLICATIONS
Contributing to space saving, cost saving, and effort saving of various heater control systems
Injection molding
machine
Sensor
Printing
machine
Temperature
controlled bath
Heater
SSR
KT4H / KT4B Temperature Controller
LCD
curing oven
Kitchen
appliance
7
KT SERIES Temperature Controller
RATING
n Performance outline
Item
Size
Rating power supply
(Must be specified)
Rating frequency
Rating power consumption
Input type
5 VA approx.
−200 to 1,370 °C (−320 to 2,500 °F)
−199.9 to 400.0 °C
(−199.9 to 750.0 °F)
J
−200 to 1,000 °C (−320 to 1,800 °F)
R
0 to 1,760 °C (0 to 3,200 °F)
S
0 to 1,760 °C (0 to 3,200 °F)
B
0 to 1,820 °C (0 to 3,300 °F)
E
−200 to 800 °C (−320 to 1,500 °F)
−199.9 to 400.0 °C
T
(−199.9 to 750.0 °F)
N
−200 to 1,300 °C (−320 to 2,300 °F)
PL−II
0 to 1,390 °C (0 to 2,500 °F)
0 to 2,315 °C
C (W / Re5−26)
(0 to 4,200 °F)
−200 to 850 °C
(−300 to 1,500 °F)
Pt100
−199.9 to 850.0 °C
(−199.9 to 999.9 °F)
−200 to 500 °C (−300 to 900 °F)
JPt100
−199.9 to 500.0 °C
(−199.9 to 900.0 °F)
4 to 20 mA DC
Control output
Multi-input
DC
Voltage
Current
Rating
Rating scale
Thermocouple
K
RTD
0 to 20 mA DC
0 to 1 V DC
0 to 10 V DC
1 to 5 V DC
−200 to 1,000 °C (−328 to 1,832 °F)
0 to 1,760 °C (0 to 3,200 °F)
0 to 1,760 °C (0 to 3,200 °F)
0 to 1,820 °C (32 to 3,308 °F)
−200 to 800 °C (−328 to 1,472 °F)
−200.0 to 400.0 °C (−328.0 to 752.0 °F)
−200 to 1,300 °C (−328 to 2,372 °F)
0 to 1,390 °C (32 to 2,534 °F)
6 VA approx.
−200 to 1,370 °C (−320 to 2,500 °F)
−199.9 to 400.0 °C −200.0 to 400.0 °C
(−199.9 to 750.0 °F) (−320.0 to 750.0 °F)
−200 to 1,000 °C (−320 to 1,800 °F)
0 to 1,760 °C (0 to 3,200 °F)
0 to 1,760 °C (0 to 3,200 °F)
0 to 1,820 °C (0 to 3,300 °F)
−200 to 800 °C (−320 to 1,500 °F)
−199.9 to 400.0 °C −200.0 to 400.0 °C
(−199.9 to 750.0 °F) (−320.0 to 750.0 °F)
−200 to 1,300 °C (−320 to 2,300 °F)
0 to 1,390 °C (0 to 2,500 °F)
0 to 2,315 °C (32 to 4,199 °F)
−200 to 850 °C (−328 to 1,562 °F)
−200.0 to 850.0 °C (−328.0 to 1,562.0 °F)
−200 to 500 °C (−328 to 932 °F)
−200 to 500.0 °C (−328.0 to 932.0 °F)
8 VA approx.
0 to 2,315 °C (0 to 4,200 °F)
−200 to 850 °C
−200 to 850 °C
(−300 to 1,500 °F) (−320 to 1,500 °F)
−199.9 to 850.0 °C
−200.0 to 850.0 °C
(−199.9 to 999.9 °F) (−320.0 to 1,500.0 °F)
−200 to 500 °C (−300 to 900 °F)
−199.9 to 500.0 °C −200.0 to 500.0 °C
(−199.9 to 900.0 °F) (−320.0 to 900.0 °F)
−1,999 to 9,999
−199.9 to 999.9
−19.99 to 99.99
−1.999 to 9.999
−2,000 to 10,000
−2,000 to 10,000
• Scaling and change to the decimal point position is possible for DC current input and DC voltage input.
• DC current input of KT2 / KT7 / KT4H / KT4B is supported with an externally connected 50 Ω shunt resistor (sold separately).
K, J, R, S, B, E, T, N, PL-II, C (W / Re5-26)
Thermocouple
External resistor: Max. 100 Ω (Max. 40 Ω external resistor for B input)
RTD
Pt100, JPt100 3-conductor system (Allowable input conductor resistance for each conductor: Max. 10 Ω)
0 to 20 mA DC
Input impedance: 50 Ω (For KT2 / KT7 / KT4H / KT4B, connect 50 Ω shunt resistor between input terminals.)
DC current
Allowable input current: Max. 50 mA (For KT2 / KT7 / KT4H / KT4B, when 50 Ω shunt resistor is used)
4 to 20 mA DC
0 to 1 V DC
Input impedance: Min. 1 MΩ, Allowable input voltage: Max 5 V, Allowable signal source resistance: Max. 2 kΩ
0 to 5 V DC
DC voltage
Input impedance: Min. 100 kΩ,
1 to 5 V DC
Allowable input voltage: Max 15 V, Allowable signal source resistance: Max. 100 Ω
0 to 10 V DC
1a
Relay contact
3 A 250 V AC (at resistive load), 1 A 250 V AC (at inductive load cos ø = 0.4), Electrical life: 100,000 times
Non-contact
(Must be
12 V DC ±15 %
voltage
specified)
12+20 V DC, Max. load current: 40 mA (with short circuit protection circuit)
Max. load current: 40 mA
voltage output
( for SSR drive )
(with short circuit protection circuit)
DC current
Alarm output 2 (EV2)
Control method
Target temperature setting
Program control function
Indication accuracy
−1,999 to 9,999
−199.9 to 999.9
−19.99 to 99.99
−1.999 to 9.999
−200.0 to 400.0 °C (−328.0 to 752.0 °F)
KT7
KT4H / KT4B
22.5 × 75 mm
48 × 48 mm
0.886 × 2.953 in
1.890 × 1.890 in
100 to 240 V AC
24 V AC / DC
0 to 5 V DC
Alarm output 1 (EV1)
Thermocouple
RTD
4 to 20 mA DC, Load resistance: Max. 550 Ω
Relay contact 1a:
Control capacity:
3 A 250 V AC
(Resistive load),
Electrical life:
100,000 times
Open collector:
Same as Alarm
Same as Alarm output 1
Not available
Not available
0.1 A 24 V DC
output 1
PID action (with auto-tuning function), PI action, PD action (with manual reset function), P action (with manual reset function), ON / OFF action
Primary setting /
Primary setting /
secondary setting /
secondary setting
―
third setting / fourth
(switched by
setting (switched by
external terminal)
external terminal)
1 pattern, 9-step setting is possible (However, make function selection setting of
―
either control with fixed set point or program control.)
Within ± (0.2 % + 1 digit) of each input span or within ±2 °C (4 °F) whichever is greater
However, R or S input; within ±6 °C (12 °F) in the range of 0 to 200 °C (32 to 392 °F)
B input, range of 0 to 300 °C (32 to 572 °F): accuracy is not guaranteed.
K, J, E, T, and N input, less than 0 °C (32 °F): within ± (0.4 % ±1 digit) of input span
Within ± (0.1 % + 1 digit) of each input span or ±1 °C (2 °F) whichever is greater
Relay contact 1a 3 A 250 V AC (Resistive load)
1a 1 A 250 V AC (cosø=0.4)
Electrical life: 100,000 times
DC current and DC voltage
Sampling period
8
Specifications
KT8R
KT9R
48 × 96 mm
96 × 96 mm
1.890 × 3.780 in
3.780 × 3.780 in
100 to 240 V AC
―
50 / 60Hz
8 VA approx.
Input range
−200 to 1,370 °C (−328 to 2,489 °F)
KT2
KT4R
48 × 48 mm
48 × 24 mm
1.890 × 0.945 in
1.890 × 1.890 in
100 to 240 V AC
24 V AC / DC
Open collector
control capacity:
24 V DC 0.1 A
(Max.)
Within ± (0.2 % + 1 digit) of each input span
250 ms
125 ms
250 ms
KT SERIES Temperature Controller
Item
Hysteresis (ON / OFF)
KT2
Thermocouple and RTD:
0.1 to 100.0 °C (°F)
DC current and DC
voltage: 1 to 1,000 (The
decimal point place
follows the selection)
Specifications
KT8R
KT9R
KT4R
Thermocouple and RTD: 0.1 to 1,000.0 °C (°F)
DC current and DC voltage: 1 to 10,000 (The decimal
point place follows the selection)
Proportional band
For sensor input
range, DC current
and DC voltage:
0.0 to 110.0 %
Input without decimal point: 0 to Input span
Input with decimal point: 0.0 to Input span
DC current and DC voltage: 0.0 to 1,000.0 %
Integral time
0 to 1,000 seconds
0 to 3,600 seconds
0 to 300 seconds
0 to 1,800 seconds
Derivative time
Proportional cycle
Allowable voltage fluctuation
Insulated resistance
Breakdown voltage
Malfunction vibration
Breakdown vibration
Malfunction shock
Breakdown shock
Ambient temperature
Ambient humidity
Mass
Waterproof
Accessories
Option functions
Display character height
Heating /
Cooling
control
Relay contact
Non-contact
voltage
KT7
KT4H / KT4B
Thermocouple and RTD: 0.1 to
100.0 °C (°F)
DC current and DC voltage: 1 to
1,000 (The decimal point place
follows the selection)
0 to 1,000 °C (0 to 2,000 °F)
Input with decimal point:
0.0 to 1,000.0 °C (0.0 to
1,000.0 °F)
DC current and DC voltage:
0.0 to 100.0 %
0 to 1,000 seconds
For sensor
input range, DC
current and DC
voltage: 0.0 to
110.0 %
0 to 300 seconds
1 to 120 seconds
When 100 to 240 V AC: 85 to 264 V AC, When 24 V AC / DC: 20 to 28 V AC / DC
500 V DC, Min. 10 MΩ
Between input terminal and power terminal
Between output terminal and power terminal
1.5 kV AC for 1 min.
10 to 55 Hz (1 cycle/min.), single amplitude: 0.35 mm 0.014 in (10 min. on 3 axes)
10 to 55 Hz (1 cycle/min.), single amplitude: 0.75 mm 0.030 in (1 hour on 3 axes)
X, Y and Z each direction for 5 times 98 m/s2
X, Y and Z each direction for 5 times 294 m/s2
0 to 50 °C 32 to 122 °F
−10 to 55 °C 14 to 131 °F
0 to 50 °C 32 to 122 °F
35 to 85 % RH (No condensation)
120 g approx.
110 g approx.
160 g approx.
220 g approx.
150 g approx.
120 g approx.
IP66 (applicable only
to the front panel
IP66 (applicable only to the front panel subject to rubber gasket employed)
None
subject to rubber
gasket employed)
PV: 8.7 mm 0.342 in
SV: 8.7 mm 0.342 in PV: 12.4 mm 0.488 in PV: 14 mm 0.551 in PV: 14 mm 0.551 in PV: 7.4 mm 0.291 in PV: 12 mm 0.472 in
(PV / SV switching SV: 8.8 mm 0.346 in SV: 14 mm 0.551 in SV: 14 mm 0.551 in SV: 7.4 mm 0.291 in SV: 6 mm 0.236 in
display)
1a Control capacity:
Relay contact:
Using EV2 assigned setting, use
3 A 250 V AC
1a 3 A 250 V DC
for heating and cooling control is
None
None
(at resistive load),
(at resistive load)
possible.
Electrical life:
100,000 times
12 V DC ±15 %,
Max. 40 mA
―
(with short circuit
protection circuit)
Heater burnout alarm
output
Communication function
Installation frame /
Mounting bracket
Terminal cover
Rubber gasket
Open collector
control capacity:
24 V DC 0.1 A
(Max.)
―
For KT4H only:
Specify either single phase 20 A, single
phase 50 A, 3 phases 20 A, or 3 phases
50 A for rated heater current.
Setting accuracy: within ±5 % of rated
heater current
Relay contact 1a 3 A 250 V AC (at resistive
load), Electrical life: 100,000 times
Please refer below to “COMMUNICATION PERFORMANCE OUTLINE”. (Not available with KT8R / KT9R)
Included with
Included with controller
―
controller
Sold separately
―
Sold separately
Included with
―
Included with controller
controller
*Tool port: KT4H and KT4B only; cannot be used simultaneously with serial interface C-MOS level serial communication (option). This port can only be used with the tool cable (AKT4H820).
COMMUNICATION PERFORMANCE OUTLINE
Item
Specifications
KT4H / KT4B
KT2 / KT7
Communication method
Communication speed
Select 2400, 4800, 9600 or 19200 bps using key operation.
Synchronous method
Protocol
Coding
Modbus (RTU, ASCII), MEWTOCOL (Slave)
Binary / ASCII
Command resending
Error detection
Parity check and check sum
Interface
Number of nodes
Maximum communication distance
Select 9600, 19200 or 38400
bps using key operation.
Asynchronous
Modbus (RTU, ASCII)
Error correcting
Data structure
KT4R
Half-duplex
Start bit: 1
Data bit: 7
Parity: Even parity
Stop bit: 1
EIA RS485 compliant
Start bit: 1
Data bit: 7, 8 (For Modbus RTU: 8 only)
Parity: Even / Odd / None
Stop bit: 1 or 2
31
1,000 m 3,280.840 ft (cable resistance must be within 50 Ω)
9
KT SERIES Temperature Controller
EXTERNAL CONNECTION DIAGRAM
n KT2 series
YA (–)
7
8
1
9
NO
3A
250 V
AC
2
TC
10
NO
3
SG
EV2
11
12
0.1 A
24 V
DC
3A
250 V
AC
4
5
RELAY
B
RTD
A
YB (+)
D1
EV1 / OUT2
6
100 to 240 V AC
POWER SUPPLY
V/A
OUT1
DC
5
6
24 V AC / DC
POWER SUPPLY
n KT4R series
PWR
1
PWR
2
EV1
EV2
1
13
2
14
3
15
YA ( )
4
NO
5
6
RS485
YB ( )
17
18
SG
NO
16
7
O1
>1V
A
V A
V
B
8
9
10
11
12
B
DC / TC / RTD
O1
NO
7
8
KT2
RS485
B
• TC: Input terminal for thermocouple
• RTD: Input terminal for the resistance temperature detector
• DC: Input terminal for DC current or DC voltage
For DC current input, connect a separately sold reception resistor
(50 Ω) between the input terminals
• OUT1: Output terminal for the control output or heating output (option:
heating / cooling control)
• POWER SUPPLY: Power supply terminal
• EV1 / OUT2: Output terminal for event output 1 or cooling output (option:
heating / cooling control)
• EV2: Output terminal for event output 2
• DI: Input terminal for DI input (There are three types of DI input, SV1 /
SV2 external switching function, OUT / OFF (RUN / STOP) external
switching function, and timer function.)
• RS485: Communication terminal for serial communication.
(EV1, EV2: alarm output)
• POWER SUPPLY: P
ower supply voltage 100 to 240 V AC or 24 V AC / DC
(Ensure correct polarity when using DC in AC / DC 24 V.)
• EV1: Event output 1
• EV2: Event output 2 (option)
• O1: Control output OUT1
• TC: Thermocouple input
• RTD: Resistance temperature detector input
• DC: DC voltage input or DC current input
• RS485: Serial communication RS485 (option: C5W)
n KT8R / KT9R series
1
3
5
7
12
17
19
A
V A
V
NO
18
>1V
9
NO
16
EV2
8
11
15
EV1
6
10
14
O1
4
• POWER SUPPLY: Power supply voltage 100 to 240 V AC
• EV1: Event output 1
• EV2: Event output 2 (option)
• O1: Control output OUT1
• TC: Thermocouple input
• RTD: Resistance temperature detector input
• DC: DC voltage input or DC current input
13
PWR
2
B
B
DC / TC / RTD
NO
20
21
22
23
24
n KT7 series
POWER SUPPLY
24 V AC / DC
1
2
OUT
V/A
RELAY
POWER SUPPLY
100 to 240 V AC
1
2
3
3A
250 V AC
KT7
5
TC
RTD A
DC
4
0.1 A
24 V DC
6
7
B
8
B
9
EVT
No.1 SG
No.2 NC
No.3 YB (+)
No.4 YA (–)
No.5 NC
No.6 SG
n KT4H / KT4B series
10
RS485
No.1
No.6
No.1
No.6
• POWER SUPPLY: Power supply
• OUT: Control output
• RELAY: Relay contact output
• V / A: DC voltage output / DC current output
• EVT: Event output [Outputs when alarm, loop fault alarm or heater
burnout alarm (option) goes ON.]
• TC: Thermocouple
• RTD: Resistance temperature detector
• DC: DC current or DC voltage
• RS485: Serial communication
• CT: CT input
CT
• POWER SUPPLY: Power supply voltage
• EVT1: Alarm 1 output
• EVT2: Alarm 2 output (option) or heater burnout
: Alarm output (option)
• OUT1: Control output or heating output (option)
• OUT2: Cooling output (option)
• TC: Thermocouple input
• RTD: Resistance temperature detector input
• DC: D
C current input (DCA) or DC voltage input (DCV)
(For DC voltage input, + side connection terminal differs depending
on the voltage. Also, for DC current input, connect s shunt resistor
between No. ⑩ and ⑫ terminals.)
• CT1: C
urrent transformer input 1 (option: for single phase and three
phases)
• CT2: Current transformer input 2 (option: for three phases)
• DI: Contact input (option)
• RS485: Serial communication RS485 (option)
KT SERIES Temperature Controller
COMMUNICATION FUNCTION CONNECTION DIAGRAM (PLC Connection Diagram)
n KT2 / KT4R series
n KT7 series
RS485
KT2
KT4R
(–)
⑩ YA (–)
⑯ YA (–)
(+)
⑪ YB (+)
⑰ YB (+)
PLC
⑫ COM
⑱ COM
Shielded cable
No.0
PLC
(–)
④
(+)
③
KT7
No.1
No.30
Communication cable
KT2
KT4R
⑩ YA (–)
⑯ YA (–)
⑪ YB (+)
⑰ YB (+)
⑫ COM
⑱ COM
Terminal No. ③ to YB (+)
Terminal No. ④ to YA (–)
Notes: 1) Terminating resistors (Terminators)
The KT series has a built-in pull-up resistor or pull-down resistor, which serves as the
terminating resistor. For this reason, do not connect the terminating resistor on the
communication line.
2) Please use a RJ-11 6 polarized type modular connector.
Please use a cable that is suitable for a modular connector. (Only KT7 series)
n KT4H / KT4B series
PLC
RS485
KT4H
(−)
⑯ YA (–)
(+)
⑰ YB (+)
⑱ COM
Shielded cable
KT4H
⑯ YA (–)
⑰ YB (+)
Notes: 1) Shielded cable
To prevent current flow along shield sections, ground one end of the shield cable.
(If both ends of the shield section are grounded, a closed circuit with the earth will form
and electricity flowing through the shield cable will cause increased susceptibility to
noise.)
2) Terminating Resistors (Terminators)
The KT4H / KT4B series has a built-in pull-up resistor or pull-down resistor. For this
reason, do not connect the terminating resistor on the communication line.
⑱ COM
INSTALLATION
n KT2 series
Please install vertically in order to satisfy the IP66 specification for
dust and splash proofing.
The possible control panel plate thickness for installation is between
1 to 10 mm 0.394 in.
(1) Insert the unit from the front of the control panel.
(2) Insert the installation frame until that the two edges make contact
with the panel.
(3) Tighten the screw and then turn it 3/4 of a turn after the edge of
the screw reaches the panel.
n KT4R series
Please install to a rigid, irregularity-free flat surface in order to
satisfy the IP66 specification for dust and splash proofing.
Panel thickness for installation: 1 to 5 mm 0.039 to 0.197 in.
(1) Insert the unit from the front of the control panel.
(2) Insert the installation frame until that the edges make contact
with the panel and tighten the screw.
Fix by rotating screws one full turn after contact of screw tip and
panel.
Apply tightening torque of 0.15 N•m.
Rubber gasket
Installation frame
11
KT SERIES Temperature Controller
INSTALLATION
n KT8R / KT9R series
Please install to a rigid, irregularity-free flat surface in order to
satisfy the IP66 specification for dust and splash proofing.
Panel thickness for installation: 1 to 7 mm 0.039 to 0.276 in.
(1) Insert the controller from the front of the control panel.
(2) Attach the screw type mounting brackets by the holes at the top
and bottom of the case and secure the controller in place with the
screws.
Apply tightening torque of 0.1 N•m.
Rubber gasket
Screw type mounting bracket
n KT7 series
• DIN rail mounting
(1) Hook ① of the KT7 series controller on the upper side of the DIN
rail.
(2) Making the ① part of the KT7 series controller as a support, fit
the lower part of the KT7 series controller to the DIN rail. KT7
series controller will be completely fixed to the DIN rail with a
“click” sound.
Recommended DIN rail: Model No. ATA48011
Recommended fastening plate: Model No. ATA4806
①
DIN rail
■■
■■
■■
pv
■■
av
T
G/
T
EV
AT
■■
DE
■■
B
T/
MO
■■
G/
TE
pv VT T KT7
/B
AT
Fastening plate
av
警告
ケースは樹脂製ですので、取付金具
のねじを必要以上に締め過ぎると、
取付金具やケースが変形するおそれ
があります。
0.12N・mぐらいで締めてください。
MO
DE
5
6
7
8
②
9
n KT4H / KT4B series
Please install vertically in order to satisfy the IP66 specification for
dust and splash proofing.
The possible control panel plate thickness for installation is between
1 to 5 mm 0.039 to 0.197 in.
(1) Insert the unit from the front of the control panel.
(2) Push the installation frame fully into contact with the panel and
tighten the screws. (Screw tightening torque: 0.05 N•m to 0.06
N•m)
Rubber gasket
12
KT SERIES Temperature Controller
DIMENSIONS
(Unit: mm in)
n KT2 series
Panel cutout
M3
+0.6
0
45 +0.024
1.772 0
47.6
1.874
Rubber gasket
PV
SV
AT
T/R
OUT
EV1
EV2
MODE
OUT
OFF
48
1.890
22.2 0
+0.012
0.874 0
Installation frame
36.5 1.437
MEMO/STEP
+0.3
44.8
1.764
24
0.945
KT2
10.6
0.417
Min. 40
Min. 1.575
Min. 60
Min. 2.362
21.6
.850
98.5
3.878
Tolerance: ±1 ±0.039
Note: The communications terminal is the screw terminal on the back of the controller.
n KT4R series
Panel cutout
Rubber gasket
Installation frame
Terminal cover (Sold separately)
Min. 75
Min. 2.953
Min. 75
Min. 2.953
45 +0.5
–0
1.772 +0.020
–0
+0.5
45 –0
1.772 +0.020
–0
n × 48-3 +0.5
–0
n × 1.890-3 +0.020
–0
44.5 (47.5) (*) (60)
1.752 (1.870) (2.362)
45 +0.5
–0
1.772 +0.020
–0
48
1.890
8.4
0.331
(*) Dimensions when terminal cover is fitted.
58.8
2.315
(65) (*)
(2.559)
Lateral close mounting
n: Number of controllers mounted
Tolerance: ±1 ±0.039
Note: The communications terminal is the screw terminal on the back of the controller.
13
KT SERIES Temperature Controller
DIMENSIONS
(Unit: mm in)
n KT8R series
External dimension
Panel cutout
Min. 75
Min. 2.953
Screw type
mounting bracket Terminal cover (Sold separately)
Rubber gasket
92 +0.5
–0
3.622 +0.020
–0
Min. 130
Min. 5.118
96
3.780
n × 48-3 +0.5
–0
n × 1.890-3 +0.020
–0
□91 (94) (*) (106)
□3.583 (3.701) (4.173)
92 +0.5
–0
+0.020
3.622–0
Lateral close mounting
n: Number of controllers mounted
45 +0.5
–0
1.772 +0.020
–0
48
1.890
Tolerance: ±1 ±0.039
58.8
2.315
(67) (*)
(2.638)
8.4
0.331
(*) Dimensions when terminal cover is fitted.
n KT9R series
External dimension
Panel cutout
Screw type
mounting bracket Terminal cover (Sold separately)
Rubber gasket
□91 (94) (*) (106)
□3.583 (3.701) (4.173)
Min. 130
Min. 5.118
92 +0.8
–0
+0.031
3.622 –0
n × 96-3 +0.5
–0
n × 3.780-3 +0.020
–0
Min. 130
Min. 5.118
Lateral close mounting
n: Number of controllers mounted
□92 +0.5
–0
+0.020
□3.622 –0
58.8
2.315
(67) (*)
(2.638)
8.4
0.331
□96
□3.780
(*) Dimensions when terminal cover is fitted.
Tolerance: ±1 ±0.039
n KT7 series
M3
1
2
3
4
OUT
EVT
T/R
AT
External dimension
PV
SV
75
2.953
MODE
KT7
5
6
7
8
9
22.5
0.886
97
3.819
100
3.937
M2
Tolerance: ±1 ±0.039
Note: The communications terminal is the modular jack on the bottom side of the controller.
n KT4H / KT4B series
Panel cutout
External dimension
Rubber gasket
1.5
0.059
Installation frame
Terminal cover
(Sold separately)
When installing in series
Min. 75
Min. 2.953
+0.5
45 0
+0.020
1.772 0
M3 screw
+0.5
Min. 75
Min. 2.953
n × 48-3 0
+0.020
n × 1.890-3 0
44.5 47.5 59.2
1.752 1.870 2.331
+0.5
45 0
+0.020
1.772 0
45
1.772
□48
□1.890
14
6
0.236
56.0
2.205
61.0
2.402
Lateral close mounting
n: Number of controllers mounted
+0.5
0
+0.020
0
Tolerance: ±1 ±0.039
Note: If longitudinal or lateral close mounting is used for the controller, IP66 specification
(Dust-proof/Drip-proof) may be compromised, and all warranties will be invalidated.
KT SERIES Temperature Controller
OPTIONS
n Terminal cover
AKT2801 (for KT2)
AKT4H801 (for KT4H / KT4B / KT4R)
AKT8R801 (for KT8R)
AKT9R801 (for KT9R)
47.5
1.870
23.8
0.937
94
3.701
3.5
0.138
44.5
1.752
47.5
1.870
15.5
0.610
>PC<
8
0.315
20
0.787
45.8
1.803
17
0.669
46.5
1.831
12
0.472
2 pieces of terminal cover of AKT8R801
can be used as an AKT9R801.
n Current transformer (CT)
• CT1 (for 5, 10 and 20 A)
l
ø5.8
ø0.228
15 k
0.591
n Tool cable (for KT4H / KT4B)
External dimension
AKT4H820
• CT2 (for 50 A)
l
7.5
0.295
0.5
0.020
2.8
0.110
K
30
1.181
k
n2.5 Plug 3-Pole type
200±20
7.874±0.787
100
3.937
L
50
1.969
25
0.984
10.5
0.413
20
0.787
USB Plug
35
1.378
2000±40
78.74±1.575
n Shunt resistor
21
0.827
40
1.575
3
0.118
40
1.575
10
0.394
ø12
ø0.472
40
1.575
30
1.181
2-ø3.5
2-ø0.138
30
1.181
AKT4810
(for KT2 / KT4H / KT4B)
74 ±6
2.913 ±0.236
15
0.591
2-M3
Note: Current transformer CT1 or CT2 is included (only with KT7 and KT4H) when heater burnout alarm function is added.
AKT4811 (for KT7)
n Installation AKW4822 (for KT4R / KT4H / KT4B)
frame
5 70 2.756
2 × R2 R0.079
0.197
24
0.945
40
1.575 12.2
0.480
4.2
0.165
±0.2
12.2
0.480
30
1.181
R2 9
19 14.2
R2
×
2 .07 0.748 0.559 2 × 79
.0
4.2
R0
R0
0.165
(R
)
9
R2 0.07
R
4.2 0.165
1.6
+0.024
R 2 9 0.063
45 +0.6
-0 1.772 -0
2 × . 07
0
R
45 +0.6
-0
1.772+0.024
-0
92+0.4
125
0
4.921 3.622+0.016
0
R 2 0. 0
R
26 ±1
1.024 ±0.039
110±0.2
4.331±0.008
79
80
3.150
16.5
0.650
+0.016
45 +0.4
0 1.772 0
75 2.953
Product name
For KT2
Model No.
AKT2801
For KT4R
Shunt resistor
(for current input) (Note 1)
1.6
0.063
±0.008
62 2.441
.1)
.1) R2
(R 2 (
80
3.150
Terminal cover
AKW8822 (for KT8R)
For KT8R
For KT9R
For KT4H / KT4B
For KT2 / KT4H / KT4B
For KT7
AKT4H801
AKT8R801
AKT9R801
AKT4H801
AKT4810
AKT4811
Product name
Current transformer CT1 (for 5, 10 and 20 A)
(CT) (Note 2)
CT2 (for 50 A)
Current transformer CT1 or CT2
is included when heater burnout
alarm function is added.
Model No.
Tool cable (for KT4H / KT4B)
For KT4R / KT4H / KT4B
Installation
frame
For KT8R
DIN rail
For KT7
Fastening plate For KT7
AKT4H820
AKW4822
AKW8822
ATA48011
ATA4806
Notes: 1) For KT2, KT4H, KT4B and KT7, when current input is specified, the shunt resistor (sold separately) is required.
2) Current transformer CT1 or CT2 is included (only with KT7 and KT4H) when heater burnout alarm function is added.
EN / IEC STANDARD
Model name
EMC Directive
Low Voltage Directive
KT2 / KT4R / KT4H / KT4B / KT7 / KT8R / KT9R
EN 61000-6-4 / EN 61000-6-2
EN 61010-1 / IEC 61010-1
FOREIGN STANDARD
Model name
KT2 / KT4R / KT4H / KT4B / KT7 / KT8R / KT9R
UL (Recognized)
File No.
Standard No.
E197456
UL873
UL (Listed)
File No.
Standard No.
-
CSA (Certified)
File No.
Standard No.
E197456 (C-UL) C22, 2 No. 24-93
15
KT SERIES Temperature Controller
NOTES FOR USE
n Notes on site selection
This controller is intended to be used in the following
environment (IEC 61010-1)
•O
vervoltage category II and Pollution degree 2
Mount the controller in a place with:
• A minimum of dust, and an absence of corrosive gases
• No flammable, explosive gases
•F
ew mechanical vibrations or shocks
• No exposure to direct sunlight, an ambient temperature of
0 to 50 °C 32 to 122 °F (For KT4R / KT8R / KT9R: -10 to 55 °C
14 to 131 °F) that does not change rapidly. (When installing
inside a panel, make particular allowance for heat dissipation.
Avoid installation in situations such as above equipment that
generates heat.)
•L
ocations in which temperature rapidly changes may cause
condensation.
•L
ocations or atmospheres in which benzine, thinners, alcohol,
or other organic solvents are present, or in which ammonia,
sodium hydroxide, or other strong alkaline substances may
adhere.
• Locations susceptible to direct impact or the transmission of
vibrations, or where splashing with water is possible.
• In the proximity of equipment in which large switching surges
occur or near high-voltage cables, high-voltage equipment,
power lines, power equipment, ham radio transmitters, or
equipment containing these or similar devices.
• An ambient non-condensing humidity of 35 to 85 % RH
• No large capacity electromagnetic switches or cables through
which large current is flowing
• No water, oil or chemicals or where the vapors of these
substances can come into direct contact with the controller
n Notes on wiring
• The terminal block of KT4R / KT8R / KT9R / KT4H / KT4B series
are designed to be wired from the left side (The terminal of
KT2 series are designed to be wired from the upper and lower
direction). The lead wire must be inserted from the left side of
the terminal, and fastened by the terminal screw. Use a wirepressed terminal with insulation sleeve that fits to the M3 screw.
• In the case of 24 V AC / DC power supply, do not confuse the
polarity when it is DC.
•W
ith the relay contact output type, use the relay externally
according to the capacity of the load to protect the built-in relay
contact.
•W
hen wiring, keep input wire (Thermocouple, RTD, etc.) away
from power source wire and load wire.
•T
urn the power supply to the instrument off before wiring or
checking. Working or touching the terminal with the power
switched on may result in electric shock which could cause
severe injury or death.
•D
o not drop wire chips into the holes of vent when wiring.
•T
o prevent the controller from harmful effects of unexpected
high level noise, it is recommended that a surge absorber be
installed between the electromagnetic switch coils.
n Notes on mounting
• Do not use excessive force while screwing in the installation
frame and mounting bracket of KT4R / KT8R / KT9R / KT4H /
KT4B series. For KT8R / KT9R series, recommended torque is
approximately 0.1 N·m. For KT4H / KT4B series, recommended
torque is approximately 0.05 to 0.06 N·m. For KT4R series,
recommended torque is approximately 0.15 N·m.
• When mounting the KT7 series to the DIN rail, mount it in a
lateral direction. Make sure a click is audible when fixed into
place.
nO
ptional heater burnout alarm output
(for KT7 / KT4H series)
• This alarm output is not available for detecting heater current
under phase control.
• Use the current transformer (CT) provided, and pass one lead
wire of the heater circuit into the hole of CT.
• When wiring, keep CT wire away from power source wire and
load wire to avoid external interference.
• In three phase installations for KT4H series, ensure that R, S
and T are each connected to a 2-line CT that connects with CT1
[⑬ - ⑭] and CT2 [⑭ - ⑮] terminals.
CT input terminals
Wire-pressed
terminal
Max. 5.8 mm
Max. 0.228 in
Round type
Type name
NICHIFU Co., Ltd.
1.25Y-3
J.S.T. Mfg. Co., Ltd. VD1.25-B3A
0.6 N•m
Max. 1.0 N•m.
NICHIFU Co., Ltd.
1.25-3
J.S.T. Mfg. Co., Ltd.
V1.25-3
ø3.2 mm
ø0.126 in
Max. 5.8 mm
Max. 0.228 in
Fork type
Company name
Fastening
torque
3.2 mm
0.126 in
• Terminal screw fastening torque is 0.6 N·m to 1.0 N·m (for KT4R
/ KT8R / KT9R / KT4H / KT4B series). For KT7 series by M3 screw
is less than 0.5 N·m and by M2 screw is less than 0.25 N·m
respectively.
• Use a thermocouple and compensating lead wire according to
the sensor input specification of the controller.
• Use a 3-wire system of RTD according to the sensor input
specification of the controller.
• This controller has no built-in power switch, circuit breaker and
fuse. Therefore, it is necessary to install them in the circuit
near the external controller. (Recommended fuse: Time-lag fuse,
rating voltage 250 V AC, rating current 2 A)
2015.07
Power supply
CT
panasonic.net/id/pidsx/global
Heater
nP
lease use rod terminals for the terminal portion of
the KT7 series.
We recommend terminals made by Phoenix Contact.
① to ④ are AI0.25-8YE, AI0.34-8TQ, AI0.5-8WH, AI0.75-8GY, AI1.08RD, and AI1.5-8BK.
⑤ to ⑨ are AI0.25-8YE, AI0.34-8TQ, and AI0.5-8WH. The screw
tightening torque for ① to ④ should be less than 0.5 N·m and for
⑤ to ⑨ it should be less than 0.25 N·m. Make sure no screw is
loose.
Panasonic Industrial Devices SUNX Co., Ltd.
Global Sales Department
No. CE-KT-2-7 July, 2015
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591
All Rights Reserved ©Panasonic Industrial Devices SUNX Co., Ltd. 2015