    PANASONIC - AKW264100A - Panel Meter, 100 VAC to 240 VAC, 50/60 Hz, DIN Rail Mount, KW2M Series

  • 数据手册
  • 价格&库存
AKW264100A 数据手册
For Electric Power Monitoring KW2M SERIES Eco-POWER METER Energy saving and electric power quality monitoring with multiple circuits. Main unit KW2M-X AKW264100A Expansion unit AKW272100A 4 units in total ■ One unit can measure two circuits. Up to three expansion units may be connected for the required number of circuits. Main unit Expansion unit Up to 3 units can be added Up to 8 circuits (three-phase four-wire), or up to 24 circuits (single-phase two-wire) ■ Wire-saving and space-saving Reduced man-hours through wire-saving. Easy wiring with push-in connectors. (Ø2.6mm single-core cables) Power supply Measured voltage Power supply Conventional model RS485 KW2M Measured voltage ex) 4 circuits Reduced approx. Electric power monitoring 48% (wiring) 57% (space) CT CT RS485 4units 62 wiring Main unit + 1 expansion unit 32 wiring 486 mm (assuming the space between devices to be 34 mm) 210mm ■ Internal memory(KW2M-X) ■ Ethernet communication ● Equipped with two Ethernet communication ports, so devices can be daisy chained without adding a HUB. ● Connectable to both KW Watcher and Central monitoring system / SCADA at the same time. ● Measured data can be saved in CSV files and visualized by KW Watcher. Central monitoring system SCADA HUB PC Visualization software, KW Watcher can be downloaded for free from our website. * Registry of customer information is required. * For KW2M-A , DLL or ELC is required to use "KW Watcher". Ethernet * Ethernet is a registered trademark of Fuji Xerox Co.,Ltd. and Xerox Corporation. ■ Web server functionality Web server functionality allows operational settings of the device and upgrading the version of the main unit's firmware without conventional dedicated software tools. Also real-time monitoring is possible with KW2M-X. Real-time Monitoring Screen Measurement Screen ※KW2M-X (AKW264100A) only ■ Web Creator (KW2M-X) By uploading screens (content) that are setup as desired by the user with Control Web Creator to KW2M-X, the information in the KW2M-X internal Web server can be monitored on a browser. You, too, are a Web content creator [ Control Web Creator ] This is a graphics creation tool that allows you to easily design Web content that is published by the KW2M-X. You can creatively design content by arranging Web components such as switches, lamps and meters on the screen and then setting the properties. Your content will be linked toinformation in the KW2M-X without any knowledge of HTML. Menu bar AKW264100A Web component property settings Abundant Web component library Tablet Creation area Ethernet Wi-Fi router PC * Wi-Fi is a registered trademark of Wi-Fi Alliance. * Please provide commercially available products. ■ Same style of operation as the program display image creation tool ■ Components can be arranged by dragging and dropping. ■ Detailed component settings are easy using properties. ■ Components don’t lose quality when enlarged or reduced, and you can color them as desired. ■ Images can be pasted in. * Key unit (sold separately) is required to use Control Web Creator. ■ Power quality measurements (THD , harmonics up to the 31st order , and unbalance) ■ Hour meter function ■ IEC61010-1 CAT Ⅲ ■ Type Product name KW2M-A/KW2M-X Eco-POWER METER Phase and wire system KW2M-A(standard type) Single-phase two-wire system Main unit Single-phase three-wire system KW2M-X (memory type) Three-phase three-wire system Three-phase four-wire system Expansion unit Operating power supply Input measured voltage 100 to 240 V AC 50/60 Hz 0 to 690V AC * When UL standard is supported 0 to 300V AC Applicable current sensor *1 CT with secondary side output 1A or 5A Model No. AKW263100A AKW264100A AKW272100A *1 Dedicated current sensor (CT) cannot be used. Please use a general-purpose CT with a secondary side current 1A or 5A. ■ Web screen creation tools *1 Product name Descriptions Control Web Creator Windows version. Downloadable free of charge from our website. Please purchase Key unit separately. AFPSWC Key unit*2 License key for Control Web Creator. 1 license. For USB port. AFPSWCKEY *1 Only for AKW264100A *2 Key unit is required to create Web content. You do not need Key unit to view Web content on a browser. 0RGHO No. Electric power monitoring Tool bar For Electric Power Monitoring ■ Specifications Use safely and correctly after carefully reading the product specification manual, user manual, and operational instruction manual. Measurement items Accuracy Item Data display range Instantaneous power Integral power (import) Integral power for each time zone (4 zone ) (import) Integral power (export) Integral power for each time zone (4 zone) (export) Active Reactive Apparent Active Reactive Apparent Active Reactive Apparent Active Reactive Active Reactive Current Power quality N-phase when 3P4W Voltage (Phase and Line voltage) Power factor Frequency Pulse count value Power conversion value Unbalanced current Each phase Unbalanced voltage Each phase Current THD (total harmonic distortion) Each phase Voltage THD (total harmonic distortion) Each phase Current harmonics (2nd to 31st) Each phase Phase Voltage harmonics (2nd to 31st) Line ON OFF Hour-meter measurement Standby Maintenance Active Reactive Apparent Present demand (Present value (inst. value) / Maximum demand) Active (export) Reactive (export) Current −999.99GW to 0.000kW to 999.99GW 0.000kWh ~ 9999.9PWh 0.000 to 99.999kA 0.00 to 999.99kV −1.000 to 0.000 to 1.000 0.00Hz to 99.99Hz 0.000 to 99999999 0.000kWh to 9999.9PWh 0.00% to 300.00% 0.00% to 300.00% 0.00% to 400.00% 0.00% to 400.00% 0.00% to 400.00% 0.00% to 400.00% 0.00% to 400.00% 0.0h to 99999.9h 0.0h to 99999.9h 0.0h to 99999.9h 0.0h to 99999.9h 0.000 kW to 999.9MW Electric power monitoring Ambient temperature Ambient humidity 50/60Hz 15VA (240V AC) 10ms Operation: -10 to +50℃ 14 to 122°F Storage: -25 to +70℃ −13 to 158°F Insulation resistance(initial) Vibration resistance 0.2% * Single-phase three-wire system 2 (N) phase voltage, three-phase three-wire system between 3-1 voltage, three-phase four-wire system line voltage is 0.5% * The tolerances of CT sensor and VT (instrument voltage transformer) are not included. * 1 IEC62053 is the international standard for electrical power measuring devices. * 2 Current less than 5% of rated value may be outside of accuracy assurance range according to CT setting (maximum tolerance: 0.5%). Demand monitoring and specifications Demand type Demand monitor input type Current transformer input Pulse input *1 (set with setting mode) Demand time span Demand measurement item Demand data update cycle 1 to 60 min. (set with setting mode) Present demand 1 min. Present demand (Active / Reactive / Apparent / Active (export) / Reactive (export) / Current) Display Saved data Web server specifications Simultaneous access number Web browser *1 ● Enclosure - All terminals ● Between primary and secondary insulated circuits (Double insulation is supported) (1) Power supply terminals – other terminals (2) Voltage input terminal – other terminals Between the isolated circuits: 100 MΩ or more 10 to 150 Hz (7.5 minutes/cycle) Single amplitude: 0.75 mm 0.030 in (1 h on 3 axes) Save cycle 5-min. instantaneous value Saved data 500, 1000, 2000, 3000 ms (set with setting mode) Saved data 10 to 55 Hz (1 minute/cycle) Single amplitude: 0.375 mm 0.015 in (1 h on 3 axes) Min. 294 m/s2 (5 times on 3 axes) Internal memory Under 2,000 m 6,562 ft Overvoltage category Ⅲ Pollution degree 2 Range Calendar timer *1 *1 Only AKW264100A 15-min. instantaneous value Main unit: 85×140×65 mm 3.346×5.512×2.559 in Expansion unit: 85×70×65 mm 3.346×2.756×2.559 in Approx. 450 g (Main unit) Approx. 200 g (Expansion unit) Weight Google Chrome Mozilla Firefox Safari Google Chrome Main unit memory specifications (for AKW264100A) Display updating time cycle Dimensions W/H/D iOS *2 Android *2 Google Chrome Black-and-white LCD with backlight (graphic form) Sea level altitude 6 sessions * Windows is the trademark of Microsoft Corporation in USA and other companies. Google Chrome and Android are the trademarks of Google Inc. Firefox is the trademark of Mozilla Foundation in USA and the other companies. Safari and OS X are the trademark or the registered trademark of Apple Inc. of USA. iOS is the trademark or the registered trademark of Cisco in USA ans the other companies. *1 Use OS and browser with the latest version. *2 System Web is not supported. Display method Power failure memory method Max.demand, Monthly max. demand (Latest 13 months)*2 *1 Only CH1 of main unit is available. Only current transformer input is available for CH2 of main unit and expansion unit. *2 Only AKW264100A Write timing Saved data amount Save cycle Shock resistance ・IEC61557-12 Compliant demand 1. Sliding block interval demand 2. Fixed block interval demand 3. Current demand 30 to 85% RH (at 20℃ 68°F) with non-condensing Between the isolated circuits: 2000 V/1 min Breakdown voltage(initial) Voltage 100 to 240V AC 30 A or less (240 V AC at 25℃) Allowable momentary power-off time 0.2% *2 * Single-phase three-wire system 2 (N) phase current, three-phase three-wire system 2 (S) phase current, 0.5% Windows Specifications Inrush current Current 0.000kWh to 9999.9PWh Item Nominal power consumption Electrical power 0.000kWh ~ 9999.9PWh General specifications Rated frequency Specification 0.5% Active electric power Compliant Class 0.5S (IEC 62053-22) *1 Reactive electric power Compliant Class 2 (IEC 62053-23) 0.000kWh to 9999.9PWh * The data display range is the numerical value range which can be displayed by the main unit's display section and is not the allowable measurement range. * If the voltage to be measured is not the rated (commercial) frequency, it may take time for THD (total harmonic distortion) to stabilize. * Please use this demand function as your standard. The demand value calculated with this function is not guaranteed. Supply voltage range Item Demand January 1, 2015 00:00:00 to December 31, 2099 23:59:59 (leap year supported) Time accuracy Monthly accuracy max. 15 sec. (at 25°C) Back up period About 1 month (by secondary battery *When power off after 48-hour or more of power on time, at 23°C) 96 records for 1 file (for one-day) (Max. 60 days) Write timing 15 minutes All items excluding for harmonics and conversion value for integral active power Every hour xx:15:05 (fixed) Saved data amount 2976 records for 1 file (for one-month) (Max. 24 months) Save cycle 1 minute Present demand (active power, reactive power, apparent power, active power(export), reactive power(export)) Pulse conversion value for integral power, Present current demand (1), (2), (3) Every hour xx:25:05 (fixed) Saved data Write timing Saved data amount Saved data Power quality 5 minutes R-current, S-current,T-current, N-current, Average of current R-voltage (L1-N), S-voltage (L2-N), T-voltage (L3-N), Average of phase-voltage, RS-voltage (L1-L2), ST-voltage (L2-L3), TR-voltage (L3-L1) Average of line-voltage Pulse count value Every hour xx:05:05 (fixed) Write timing Saved data amount 1000 records for 1 file (Max. 100 files) Power interruption, Over voltage, Under voltage, Over current, Under current (with time stamp of event occurrence and occurrence period) Every hour xx:35:05 (fixed) 1000 records for 1 file (Max. 100 files) Use safely and correctly after carefully reading the product specification manual, user manual, and operational instruction manual. Communication specifications (for AKW263100A and AKW264100A) 〈RS485〉 Interface Communication method Synchronous system Isolation status Number of connected unit Transmission distance Transmission speed Data length Parity Stop bit 〈Ethernet〉 Number of communication ports Interface Connector type Transmission speed Transmission Transmission method specifications Max. segment length Communication cable Protocol (DNS, DHCP) MEWTOCOL, MODBUS (RTU) (select with setting mode) Protocol Transmission format Conforming to RS485 Half-duplex Synchronous communication method Isolated with the internal circuits 99 units (max.) *1 1,200 m 3,937 ft *2 115200, 57600, 38400, 19200, 9600, 4800, 2400 bps (select with setting mode) Setting, Monitoring measured values, Web customization *2*3 Web server 8bit (fixed) Not available / Odd number / Even number (select with setting mode) 1bit, 2bit (select with setting mode) 2 IEEE802.3u, 100BASE-TX / 10BASE-T RJ45 100 Mbps / 10 Mbps Base band 100m 328ft UTP (category 5) TCP/IP, UDP/IP Auto-negotiation function *1 MDI/MDI-X auto-crossover function Function Dedicated communication MEWTOCOL, MODBUS(TCP) (2 session for each) *1 For RS485 converter on the computer side, we recommend SI-35 and SI-35USB (from LINE EYE Co.,Ltd.). When using SI-35, SI-35USB or PLC from our company (which can be connected up to 99 units), up to 99 can be connected. In case using this system with the other devices, up to 31 can be connected. *2 Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line. *Ethernet is the trademark of Xerox of USA. *This product has the software developed by OpenSSL Project in order to use OpenSSL Toolkit. (http://www.openssl.org/) *1 It changes the transmission speed automatically with auto-negotiation function. *2 Control Web Creator is necessary to customize the webpage. *3 Only AKW264100A Output specifications (for AKW263100A and AKW264100A) Input specifications (for AKW263100A and AKW264100A) Item Specifications Output points Insulation method Output type Output capacity Two channels * Non-insulated between channels PhotoMOS relay 1a 100 mA, 30 V AC/DC Output mode ・Pulse by integral power ・Output by alarm or events (set with setting mode) Pulse Output by integral power Pulse width Pulse output unit Type Alarm output Event output Item Specifications Input points Insulation method 1 channel Input dedicated insulation (insulated with other function terminals) Connection point / non-voltage a contact or open collector (operated by internal power source) Input method Input signal ・Impedance during short-circuit: 1 kΩ or less Non-voltage (short- circuit current, approx. 1 0 m A o r less) input ・Residual voltage during short-circuit: 3 V or less ・Impedance while open: 100 kΩ or more Input mode Pulse input Synchronized with input from outer device *1 Measure maintenance time *1 1 ms to 100 ms (set with setting mode) 0.001 kWh / 0.01 kWh / 0.1 kWh / 1 kWh / 10 kWh / 100 kWh Stand-by alarm/ Under voltage alarm/ Over voltage alarm/ Power interruption alarm/ Under current alarm/ Over current alarm/ Active power alarm/ Reactive power alarm/ Apparent power alarm/ PF alarm/ Over frequency alarm/ Under frequency alarm/ Voltage harmonics alarm/ Current harmonics alarm/ Voltage THD alarm/ Current THD alarm/ Unbalanced voltage alarm/ Unbalanced current alarm/Power demand alarm/ Current demand alarm/ Counter output/ Level output (external control) / Time control *1 Maximum counting speed 2000 Hz / 30 Hz 0.25 ms (2000 Hz selected) / 16.7 ms (30 Hz selected) ON : OFF ratio=1:1 Minimum input signal width Decimal point Range Output mode (during pulse output selection) Protection element Pre-scale setting Alarm reset Self-reset (according to the setting) / Manual-reset Protection element Varistor *2 Display Lighting alarm mark Alarm output Output signal ・Normal: OFF・Alarm: ON Output capacity 100 mA, 30 V AC/DC Pulse input Up to three decimal points can be selected 0.001 to 100.000 (set with setting mode) HOLD Zener diode Pulse input 1,000 to 99,000 pulse/kWh Arbitrary setting (External pulse converter required) Pulse rate 0.001 to 100.000 kWh/pulse Pulse input condition 2000Hz Pulse width Pulse interval 0.25 ms or more 0.5 ms or more (OFF time 0.25 ms or more) 30Hz Pulse width Pulse interval 16.7 ms or more 33.4 ms or more (OFF time 16.7 ms or more) Operation voltage / current 5 V DC 10 mA *1 Only AKW264100A *2 Varistor is mounted internal as a protection element. Install a protective device in case of using at the place where it effects by surge. *1 Only AKW264100A ■ Dimensions (unit: mm in) Tolerance ± 1.0 ± 0.04 AKW272100A Main unit Hook: 2 points Use these hooks when connecting an expansion unit. Connector label Remove when connecting an expansion unit. 140 5.512 Terminal cover 70 2.756 Terminal cover (2.646) 20 0.787 DIN rail (sold separately) 45 1.772 (20 0.787) 35.4 1.394 48.8 1.921 65 2.559 (67.2) (with DIN rail) 85 3.346 20 0.787 DIN hook Use these hooks when connecting an expansion unit. Hook: 2 points Use these hooks when connecting an expansion unit. Connector label Remove when connecting an expansion unit. DIN rail (sold separately) 45 1.772 (20 0.787) 85 3.346 Terminal cover Expansion unit 35.4 1.394 AKW263100A / AKW264100A Terminal cover DIN hook Use these hooks when connecting an expansion unit. 48.8 1.921 65 2.559 (67.2) (with DIN rail) (2.646) Electric power monitoring ■ Specifications
AKW264100A 价格&库存

很抱歉,暂时无法提供与“AKW264100A”相匹配的价格&库存,您可以联系我们找货

免费人工找货