AKW5111

AKW5111

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    POWER MTR 0-4000A/85-264VAC LCD

  • 数据手册
  • 价格&库存
AKW5111 数据手册
KW4M Eco-POWER METER (DIN48) (AKW5) Eco-POWER METER makes energy management easy for all your facilities and machines! KW4M Eco-POWER METER (DIN48) FEATURES Compliance with RoHS Directive • Electrical power measurement function Instantaneous electrical power, integrated electrical energy, each phase voltage and each phase current • Hour meter function installed Measuring the power distribution time of loads possible • Counter function installed Supports pulse output devices including flow meters • Support for 400 V AC power measurement (use with external voltage transformer) • Supports 4 types of dedicated current transformer (CT) to cover wide measuring range • Supports Networking - An RS485 communications port comes standard - Comes with MODBUS (RTU) and easily connects to PLC DIN48 IP66 PRODUCT TYPES  Main unit Phase and wire system Single-phase two-wire system Single-phase three-wire system Three-phase three-wire system Operating power supply Measured voltage input 100 to 240 VAC Terminal type Communication protocol Model number Screw terminal M3.5 “+/−” screw (crimp terminal) MEWTOCOL MODBUS (RTU) MEWTOCOL MODBUS (RTU) AKW5111 AKW5112 AKW5211 AKW5212 100/200 VAC 11-pins  Dedicated current transformer (CT) Rated primary current 5A/50A (common) 100A 250A 400A Model number AKW4801C AKW4802C AKW4803C AKW4804C * When connectors are not necessary for trunk cables, cutting processing by users is necessary. * Please order in accordance with the type of power distribution system you will be measuring. (Even if you will be using a secondary 5A CT, you will need an AKW4801C.)  Tool and Software Product name KW Monitor*1 (Data collection software for Eco-POWER METER) KW Watcher (Electric power monitoring software) Descriptions Remark For parameter settings, editing of measurement values, and monitoring, etc. Please use in situations where Web Datalogger Unit (DLU)/Data Logger Light (DLL) and Eco-POWER METER are used together. For easy “visualization” of data collected in DLU or DLL You can download from our website (free of charge)*2 Notes: *1. KW Monitor only uses MEWTOCOL. You cannot use MODBUS (RTU) type (AKW5112, AKW5212) for communication. *2. Customer registration is required to download data.  Other tool Product name KW4M Eco-POWER METER User’s manual (PDF) Descriptions Detailed explanation of Eco-POWER METER usage Remark You can download from our website (free of charge)*2  Options Product name Installation frame Terminal protective cover Mounting frame Rubber gasket Protective cover DIN rail terminal socket Rear terminal socket 11P cap Mounting rail Descriptions Used for DIN48 size Main unit installation panel (For use when installation on the board is not possible) Used for screw terminal type Cover for shielding terminals of the main unit Supplied with a unit Used for mounting in a panel Supplied with a unit Used for mounting in a panel Used for protecting a front display (common to Timer/Counter) For 11-pin type (surface mounting) For 11-pin type (embedded mounting) For 11-pin type (connectable directly with soldering) DIN rail terminal socket fixing rail All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Model No. AKW4822 AKW4823 ATA4811 ATC18002 AQM4803 ATC180041 AT78051 ATA4861 ATA48011 KW4M Eco-POWER METER (DIN48) (AKW5)  Measurement items Item Unit kW Instantaneous electric power (Active) Integrated electrical energy (Active) Current Voltage Corresponding value Hour meter L1(CT1)-phase current L2(CT2)-phase current Voltage between 1-2 Voltage between 2-3 Yen Dollars Electricity Euros charge* Yuan No currency Carbon dioxide (kg-CO2) ON-time OFF-time Pulse input kWh MWh A A V V JPY $ EUR CNY CHG CO2 h (Hour) h (Hour) Count Data displayed range 0.00 to 9999.99 0.00 to 9999.99kWh to 10.00MWh to 9999.99MWh 9-digit display: 0.00 to 9999999.99 kWh 0.0 to 6000.0 0.0 to 6000.0 0.0 to 9999.9 0.0 to 9999.9 0 to 999999 0.0 to 99999.9 0.0 to 99999.9 0 to 999999 0 to 999999 0.0 to 999999 0.0 to 99999.9 0.0 to 99999.9 0 to 999999 * Eco-POWER METER is designed chiefly to manage saving energy. It is neither intended nor can it be legally used for billing. SPECIFICATIONS  Main unit Item Rated operating voltage Rated frequency Rated power consumption Allowable operating voltage range Allowable momentary power-off time Ambient temperature Ambient humidity Breakdown voltage (initial) Insulation resistance (initial) Vibration resistance Shock resistance Display method Power failure memory method Protection Weight Specifications 100 to 120/200 to 240V AC 50/60Hz common 8VA (240V AC at 25°C) 85 to 132/170 to 264V AC (85% to 110% of rated operating voltage) 10ms –10 to +50°C (–25°C to +70°C at storage) 30 to 85%RH (at 20°C non-condensing) [Use as a Power meter] • Insulated circuit (Between (1)-(2), (2)-(3), (1)-(3)) (1) Power terminal (1 (R), 2 (N, S), 3 (T)) Between the isolated circuits: 2000V for 1min CT input terminal (CT1 (+), CT2 (+), CT1, 2 (–)) (2) RS485 terminal (+, –) (3) Pulse output terminal (+, –) • Outer edge (case)-all terminals [Use as a Pulse counter] • Insulated circuit (Between (1)-(2), (2)-(3), (1)-(3)) (1) Power terminal (1 (R), 2 (N)) Between the isolated circuits: 100MΩ or more Pulse input terminal (CT1 (+), 0V) (measured with 500V DC) (2) RS485 terminal (+, –) (3) Pulse output terminal (+, –) • Outer edge (case)-all terminals 10 to 55Hz (1cycle/min) single amplitude: 0.75mm (1h on 3 axes) Min. 294m/s2 (5 times on 3 axes) LCD with backlight Upper section: Green, 4-digit, 16-segment, Letter height: 6.5 mm Lower section: Amber, 6-digit, 7-segment, Letter height: 7.5 mm EEP-ROM (more than 100,000 overwrite) IEC Standard IP66 (only front panel with rubber gasket) Note: Mounted in a row, waterproofing property will be lost. Approx. 140g (Screw terminal type), Approx. 130g (11-pin type) All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. KW4M Eco-POWER METER (DIN48) (AKW5)  Power input specifications *Will not operate simultaneously with pulse measurement mode. Item Phase and wire system Rating Allowance Input voltage Allowable measurement voltage VT ratio Input current Primary side rating CT ratio Special functions Accuracy (without error in CT and VT) Cut-off current Hour meter threshold current Instantaneous electric power Integrated electric power Voltage Indication Current accuracy Electricity charge Calculated CO2 value Hour meter Specifications Single-phase two-wire system, Single-phase three-wire system, Three-phase three-wire system Single-phase two-wire: 100 to 120/200 to 240V AC (common) Single-phase three-wire: 100 to 120V AC Three-phase three-wire: 200 to 240V AC 85% to 110% of rated input voltage Single-phase two-wire: 85 to 132/170 to 264V AC (common) Single-phase three-wire: 85 to 132V AC Three-phase three-wire: 85 to 264V AC 1.00 to 99.99 (Set with setting mode) *Voltage transformer (VT) is required when you measure a load with voltage over 200V system. *Secondary current rating of commercial VT is 110V. • 5A/50A/100A/250A/400A (Select with setting mode) • 1 to 4000A (Set with setting mode) *Accuracy coverage: 10 to 100% of rated current of CT 1 to 4000 (Set with setting mode) *In case measuring CT of secondary rated current 5A. 1.0 to 50.0%F.S. 1.0 to 100.0%F.S. ±2.5% F.S. ±1 digit (at 20°C, rated input, rated frequency, power factor 1) *Accuracy coverage: 10 to 100% of rated current of CT ±0.01%+1 digit (at 20°C) (In case power on start or current energizing, ±0.01%+1s+1 digit) ±1.5% F.S./10°C+1 digit (Range of –10 to 50°C based on 20°C for rated input power factor 1) ±1.5% F.S.+1 digit (Frequency change ±5% based on rated frequency, for rated input power factor 1) Temperature characteristics Frequency characteristics  Pulse input specifications *Will not operate simultaneously with electrical power measurement mode. Item Specifications Input mode Max. counting speed Addition (Fixed) 2kHz/30Hz (Select with setting mode) Min. input signal width: 0.25ms (When selected 2kHz)/16.7ms (When selected 30Hz) ON : OFF ratio = 1 : 1 Contact/No contact (open collector) • Impedance when shorted: Max. 1kΩ • Residual voltage when shorted: Max. 2V • Impedance when open: Min. 100kΩ HOLD (Over count) 6-digit (0 to 999999) (Selectable with setting mode) Setting possible up to 3 digits after decimal point (Auto-setting) 0.001 to 100.000 (Selectable with setting mode) CNT / l / kl / m3 (Selectable with setting mode) (Count value does not change even if the unit setting is changed during counting.) Pulse input Input signal Output mode Number of digit Pre-scale setting Decimal point Range Unit  Pulse output (transistor output) specifications Item Number of output point Insulation method Output type Output capacity Pulse width ON state voltage drop OFF state leakage current Power measurement Pulse output unit Pulse input measurement Specifications 1 point Optical coupler Open collector 100mA 30V DC Approx. 100ms* 1.5V or less 100µA or less 0.001/0.01/0.1/1/10/100kWh/Alarm (Selectable with setting mode) HOLD (Over count) * We recommend the setting of minimum unit for pulse output for measurement shown as below. Output pulse: 4 pulse or less per 1sec. How to calculate: (Unit for pulse output : PL-P) > (Max. measurement power [kW]) / (3600[s] × 4 [pulse/s]) Notes: 1. Count errors may occur if pulse output unit is set so that 4 or more pulses are output per 1 second. 2. The connected counter or PLC may cause count errors if the OFF time of the pulse output unit is short. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. KW4M Eco-POWER METER (DIN48) (AKW5)  Communication specifications Item Interface Protocol Isolation status Number of connected units Transmission distance Transmission speed Specifications Conforming to RS485 MEWTOCOL/MODBUS (RTU) (different model) Isolated with the internal circuit 99 (max.)*2, *3 1200m*1 38400/19200/9600/4800/2400bps (selectable with setting mode) 8 bit/7 bit (selectable with setting mode) (MEWTOCOL type) 8 bit (fixed) (MODBUS type) Not available/Odd number/Even number (selectable with setting mode) 1 bit (fixed) Half-duplex Synchronous communication method Approx. 120Ω (built-in)*4 Data length Transmission format Parity Stop bit Communication method Synchronous system Ending resistance Notes: *1. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, transmission speed may be different according to using transmission line. *2. For RS485 converter on the computer side, we recommend SI-35 (from LINE EYE Co., Ltd.). *3. When using SI-35 or PLC from our company (which can be connected up to 99 units), up to 99 Eco-POWER METER can be connected. (However, 32 units (max.) using connection with C-NET adapter) In case using this system with the other devices, up to 31 Eco-POWER METER can be connected. *4. Change the sliding switch of main unit as a terminal station. (Factory setting; General side) * MODBUS Protocol is a communications protocol developed for PLCs by Modicon Inc. *For RS485 communication and recommended cable, please refer to “PRECAUTIONS IN USING Eco-POWER METER”. PARTS NAMES 2 3 Panasonic EcoPOWER METER MODE Lock 1 2 OP CT1 3 4 CT2 6 4 5 MODE 7 SET TIME COUNT 1 V CHARGE kW/kWh A Mode indicator (16-segment LCD) Lock indicator Illuminates when locked. Mode indicator Illuminates when setting a mode. Output indicator Illuminates during pulse output. CT direction Illuminates when the CT direction is correct and a notification display current flows that exceeds the set current value. 6 Value display Displays the integrated electrical energy, instantaneous (7-segment) electrical power, current, voltage, electricity charge, 1 2 3 4 5 KW4M 8 9 7 MODE key 8 SET key 9 Select key hour meter time, count, and all settings. Used to move between different modes. Used to make settings. Changes the item displayed. Used to move between modes. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. KW4M Eco-POWER METER (DIN48) (AKW5) DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac Tolerance: ±1.0 ±.039 CAD Data Screw terminal type (AKW5111/AKW5112) Pin type (AKW5211/AKW5212) 87.5 3.445 Panasonic TIME COUNT V CHARGE kW/kWh A MODE Lock 1 2 OP CT1 3 4 CT2 MODE SET TIME COUNT V CHARGE KW4M 48 1.890 KW4M 48 1.890 81.9 3.224 Screw terminal: M3.5 .138 Panel cut-out dimensions Panel mount diagram Min. 80 Min. 3.150 Rubber gasket (supplied) (ATC18002) 45+0.6 0 1.772+.024 0 Mounting frame (supplied) (AT8-DA4) Mounting screw (attached to mounting frame) 73 2.874 Dimensions for flush mounting (with adapter installed) Pin type Rubber gasket ATC18002 (supplied) Mounting frame for flush mounting AT8-DA4 11P cap (supplied) (AT8-DP11 sold separately) Panel 50 1.969 45+0.6 0 1.772+.024 0 45+0.6 0 1.772+.024 0 Min. 80 Min. 3.150 kW/kWh A 66 2.598 SET (44.5) (1.752) MODE Lock 1 2 OP CT1 3 4 CT2 MODE EcoPOWER METER (44.5) (1.752) EcoPOWER METER Panasonic 14.5 .571 5.5 .217 5.5 .217 A Dimension A when ‘u’ products are mounted in a row: A = (48∗n–2.5)+0.6 0 Note: If the products are mounted in a row, they lose their waterproofing properties. Panel (thickness: 1 to 5.0mm) 104.5 4.114 1 .039 Dimensions for front panel installations DIN rail terminal socket 11-pin type AT8-DF11K (sold separately) Device installation rail AT8-DLA1 (sold separately) 112.9 4.445 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. KW4M Eco-POWER METER (DIN48) (AKW5) TERMINAL ARRANGEMENT AND WIRING DIAGRAMS Terminal type Pin type Screw terminal type 1, R, R RS485 − 2, N, S CT1 (k)/IN 3, T, T CT1 (l), CT2 (l) RS485 + CT2 (k) RS485 − 0V Pulse output (+) Pulse output (+) Pulse output (−) Pulse output (−) CT1 (k)/IN 1, R, R CT1 (l), CT2 (l) 2, N, S CT2 (k) 3, T, T 0V RS485 + No. 1 2 3 4 5 6 7 8 9 10 11 Notes: 1. Be sure to wire correctly according to the terminal arrangement and wiring diagrams. 2. A DIN rail terminal socket (AT8-DF11K) should be used for 11-pin type Eco-POWER METER.  Caution for Wiring (1) Terminal fastening torque should be approx. 1.0 N·m. In case of using a crimping terminal, with insulating sleeve applicable to M3.5 screw. (Refer to the below.) 3.7mm 6.6mm or less  Terminal arrangement * Round terminals cannot be used in KW4M. Use Y shape terminals. (2) To protect the device, it is necessary to install power switch and circuit breaker in operating power supply circuit. Therefore it is necessary to install them in the circuit near main unit. (3) We recommend a wire with the cross section of 0.75 to 1.25 mm2 for operating power supply line and measured voltage input line. (4) Use fire resistant electrical wire (UL electrical wire, etc.) Be sure to wire correctly according to the wiring diagram. The input (applied) voltage to each pin (terminal) is as follows. Phase and wire Main unit type Single-phase two-wire Single-phase three-wire Three-phase three-wire Pin type Pin (Terminal) (1)-(2) Screw terminal type (8)-(9) Pin type (1)-(2)-(3) Screw terminal type (8)-(9)-(10) Pin type (1)-(2)-(3) Screw terminal type (8)-(9)-(10) Input (Applied) voltage 100 to 120/200 to 240VAC (100 to 120/200 to 240V~) 100 to 120VAC (100 to 120V~: 3W) 200 to 240VAC (200 to 240V 3~) Note: Please connect a breaker to the voltage input part for safety reasons and to protect the device.  Power measurement • Please connect a breaker to the voltage input part for safety reasons and to protect the device. • After wiring, turn on the power once again (ON → OFF → ON). 1) When measuring load with 100 to 200VAC system 2) When measuring load with 400V or more system • Single-phase two-wire system * VT (Voltage transformer) is needed when you measure a load with voltage over 240VAC. Use commercial VT, those secondary rating is 110V. *One CT is required. K Power supply 1 side 2 CT1 k l L K CT1 k l L Load side • Single-phase two-wire system K Power supply 1 side 2 56 7 6 7 8 9 10 11 1 2 3 4 5 Pin type Screw terminal type 4 3 2 8 9 10 1 11 CT1 k l L K CT1 k l L Load side VT VT • Single-phase three-wire system/Three-phase three-wire system 56 7 4 8 3 9 2 10 1 11 6 7 8 9 10 11 1 2 3 4 5 Pin type Screw terminal type *Two CTs are required. K Power supply side RR 1 NS 2 TT3 L CT1 k l CT2 k l K L CT1 k l CT2 k l Load side • Single-phase three-wire system/Three-phase three-wire system K Power supply side 56 7 4 3 2 8 9 10 1 11 Pin type 6 7 8 9 10 11 1 2 3 4 5 RR 1 NS 2 TT3 K L CT1 k l CT2 k l Load side VT VT Screw terminal type L CT1 k l CT2 k l 56 7 4 8 3 9 2 10 1 11 6 7 8 9 10 11 1 2 3 4 5 Pin type Screw terminal type * Grounding the secondary side of voltage transformer (VT) and current transformer (CT) is not necessary with low voltage circuit. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AKW5111 价格&库存

很抱歉,暂时无法提供与“AKW5111”相匹配的价格&库存,您可以联系我们找货

免费人工找货