AKW7111B

AKW7111B

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    PANASONIC - AKW7111B - Panel Meter, 200 VAC to 240 VAC, 50/60 Hz, DIN Rail Mount, KW7M Series

  • 数据手册
  • 价格&库存
AKW7111B 数据手册
KW7M Eco-POWER METER DIN Type All functions needed for power measurement now in a DIN type! Dedicated CT 22.5mm 1 Save Space and Install More Easily 3 1 Can be installed in control panels Supports DIN specification (22.5 mm) and is thinnest in industry with a display (Based on our investigation). Installable on DIN rail 2 Can be used with compact dedicated Current Transformer (CT). 2 1 Also supports 5 A CT of secondary current input. * When inputting a 5 A secondary current, use 2-stage configuration by combining with a dedicated CT. 2 Support for 400 V AC * Use with external voltage transformer (VT) 4 Power Measurement Function 1 Instantaneous electrical power display 2 Integrated electrical energy display 3 Each phase voltage and current display Multiple Inputs Supports Networking 1 An RS485 communications port comes standard 2 Comes with MEWTOCOL/Modbus (RTU). * Modbus Protocol is a communications protocol developed for PLCs by Modicon Inc. 3 Pulse output is standard function. KW7M Eco-POWER METER DIN Type ARCT1B281E ’07.6 http://www.mew.co.jp/ac/e/ 06/2007 New Matsushita Electric Works, Ltd. KW7M Eco-POWER METER DIN Type PART NAME AND DIMENSIONS 1 1 2 2 3 A kW 4 KW7M V 3 kWh Lock T/R OUT 4 7 MODE SET ITEM SHIFT Eco-POWER METER 75 2.953 CHARGE 5 6 DIN rail 8 9 5 6 7 8 9 97 3.819 100 3.937 22.5 .886 1 2 3 4 5 Display indicator Lock indicator T/R indicator OUT indicator Value display 6 7 8 9 MODE key SET key ITEM/ key SHIFT/ key Lighting or Blinking according to the display Lighting while in lock mode. Blinking while communication Lighting when pulse output • Displays the instantaneous electrical power, integrated electrical energy, current, voltage and electricity charge. • Displays the all settings. 1234 1 2 3 V A kW Terminal layouts 4 KW7M kWh CHARGE (4) (.157) Lock T/R MODE SET OUT ITEM SHIFT Eco-POWER METER 5 6 7 8 9 CT1 CT2 8.1 .319 11 .433 24.1 .949 56789 No. 1 2 3 4 5 6 7 8 9 Type R S T No connection Pulse output “+” Pulse output “–” RS485 “+” RS485 “–” RS485 “E” PRODUCT TYPES AND SPECIFICATIONS ● Main unit ● Dedicated current transformer (CT) Phase and wire system Rated input Single-phase two-wire system Single-phase three-wire system 100 to 120/200 to 240 V AC Three-phase three-wire system Current transformer Part No. Dedicated CT type (5 A, 50 A (common)/ 100 A/250 A/400 A) AKW7111 Rated primary current 5 A/50 A 100 A 250 A 400 A Part No. AKW4801C AKW4802C AKW4803C AKW4804C ● Measurement items Item Instantaneous electrical power Integrated electrical energy L1 (CT1) phase current Current L2 (CT2) phase current Voltage between 1-2 Voltage Voltage between 2-3 Electricity charge* Unit kW kWh A A V V Data range 0.00 to 999999.99 0.00 to 999999.99 to 1000000.0 to 9999999.9 0.0 to 999.9 to 1000 to 6000 0.0 to 999.9 to 1000 to 6000 0.0 to 999.9 to 1000 to 9999 0.0 to 999.9 to 1000 to 9999 0.00 to 999999.99 to 1000000.0 to 9999999.9 to 10000000 to 99999999 *Eco-POWER METER is designed chiefly for managing energy saving. It is not intended to be used for billing. ● Main unit ● Communication Rated operating voltage Rated frequency Rated power consumption Allowable operating voltage range Allowable power off time Ambient temperature Ambient humidity Display method Power failure memory method 100 to 120/200 to 240V AC 50/60 Hz common 6 VA 85 to 132/170 to 264V AC (85% to 110% of rated operating voltage) 10 ms –10°C to +50°C +14°F to +122°F (Storage temperature: –25°C to +70°C –13°F to +158°F) 30 to 85%RH (at 20°C non-condensing) 7-segment LED EEP-ROM (Over 100,000 overwrites) Interface Protocol Number of connected units Conforming to RS485 MEWTOCOL/Modbus (RTU) Max. 99 units ● Input Rating Input voltage Allowable measuring voltage VT ratio Max. displayed voltage Rating of primary side Input current Accuracy (Not including CT error) (Not including VT error) CT ratio Max. displayed current Basic accuracy Temperature characteristics Frequency characteristics Single-phase two-wire system: 100 to 120/200 to 240 V AC (common use) Single-phase three-wire system: 100 to 120 V AC Three-phase three-wire system: 200 to 240 V AC 85% to 110% of rated operating voltage 1.00 to 99.99 [External voltage transformer (VT) is required.] 9999 V • 5 A/50 A/100 A/250 A/400 A (when using dedicated CT) • 1 to 4000 A (when using secondary 5A CT) 1 to 4000/5 A (Can be set in setting mode.) (Supported when dedicated CT used in 2-step configuration.) 6000 A (When 400 A or higher, use commercial CT with 5 A rated secondary current.) Instantaneous electrical power, Integrated electrical energy, Voltage, Current and Electricity charge ±2.5% F.S. ±1 digit (at 20°C rated input, rated frequency, power factor: 1), Guarantee accuracy range: 10 to 100% of a rated current of each CT ±1.5% F.S./10°C ±1 digit (for –10 to 50°C range, rated input and power factor: 1) ±1.5% F.S. ±1 digit (for ±5% frequency change, rated input and power factor: 1) ● Please read “Installation instruction” before using to ensure correct usage. ● For details, specifications and handling, please read the KW7M Eco-POWER METER user’s manual. ● You can download the user’s manual from http://www.mew.co.jp/ac/e. These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.mew.co.jp/ac/e/ 06/2007 COPYRIGHT © 2007 All Rights Reserved Specifications are subject to change without notice. ARCT1B281E 200706-0YT
AKW7111B 价格&库存

很抱歉,暂时无法提供与“AKW7111B”相匹配的价格&库存,您可以联系我们找货

免费人工找货