ALDP109W

ALDP109W

  • 厂商:

    NAIS(松下)

  • 封装:

    DIP4

  • 描述:

  • 详情介绍
  • 数据手册
  • 价格&库存
ALDP109W 数据手册
Automation Controls Catalog VDE Slim (7.2mm .283inch), 1 Form A 5A power relay LD-P RELAYS (ALDP) FEATURES TYPICAL APPLICATIONS 1. Nominal switching capacity: 5A 277V AC 2. Ambient temperature: –40°C to +85°C –40°F to +185°F 3. Excellent heat resistance and tracking performance • Boilers • Air conditioner • Refrigerator • Hot water units • Microwave ovens • Fan heaters EN60695 (GWT2-11, GWFI2-12, GWIT2-13) data available (Please consult us for details.) RoHS compliant 4. Slim type: 20.5 (L) × 7.2 (W) × 15.3 (H) mm .807 (L) × .283 (W) × .602 (H) inch Protective construction: Sealed type ORDERING INFORMATION ALDP 1 W LD-P relay Contact arrangement 1: 1 Form A Nominal coil voltage (DC) 05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V Packing style W: Carton packing Note: Certified by UL/C-UL and VDE TYPES Contact arrangement 1 Form A Nominal coil voltage 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC Part No. ALDP105W ALDP106W ALDP109W ALDP112W ALDP118W ALDP124W Packing quantity: Carton 100 pieces, Case 500 pieces Note: The “W” at the end of the part number only appears on the inner and outer packaging. It does not appear on the relay itself. Please consult with our sales office on a tube packing type. RATING 1. Coil data Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) 5V DC 40.0mA 125Ω 6V DC 9V DC 12V DC 18V DC 24V DC 33.3mA 22.2mA 16.7mA 11.1mA 8.3mA 180Ω 405Ω 720Ω 1,620Ω 2,880Ω 2014.02 75%V or less of nominal voltage (Initial) 5%V or more of nominal voltage (Initial) industrial.panasonic.com/ac/e/ –1– Nominal operating power Max. applied voltage (at 20°C 68°F) 200mW 130%V of nominal voltage © Panasonic Corporation 2014 ASCTB193E 201402-T LD-P (ALDP1) 2. Specifications Characteristics Contact Rating Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Min. switching capacity (reference value)*1 Insulation resistance (Initial) Specifications 1 Form A Max. 100 mΩ (By voltage drop 6 V DC 1A) AgNi type 5A 277V AC, 3A 30V DC 1,385VA, 90W 277V AC, 30V DC 5A (AC), 3A (DC) 100mA 5V DC Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. Between open contacts Between contact and coil Surge breakdown voltage*2 (Between contact and coil) (Initial) 750 Vrms for 1 min. (Detection current: 10 mA) 4,000 Vrms for 1 min. (Detection current: 10 mA) Breakdown voltage (Initial) Electrical characteristics 10,000 V Max. 30°C 86°F (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 5A, at 85°C 185°F) Max. 10 ms (excluding contact bounce time.) Max. 10 ms (excluding contact bounce time) (With diode) 300 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 1.5 mm Min. 5×106 Min. 2×105 (5A 125V AC at rated load), Min. 105 (5A 250V AC, 3A 30V DC) Ambient temperature: –40°C to +85°C –40°F to +185°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Approx. 4 g .14 oz Temperature rise (coil) Operate time (at nominal voltage) (at 20°C 68°F) Release time (at nominal voltage) (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times/min.) Electrical (at 20 times/min.) (resistive load) Shock resistance Mechanical characteristics Expected life Conditions Conditions for operation, transport and storage*3 Max. operating speed Unit weight Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. REFERENCE DATA 1. Max. switching power 2. Life curve 3. Coil temperature rise Sample: ALDP112, 6 pcs. Point measured: inside the coil Contact current: 0 A, 5 A 10 50 100 *at room temperature AC resistive load Life, ×104 Contact current, A 5 Temperature rise, °C 125V AC resistive load 1 250V AC resistive load 10 5A* 0A* 40 85°C 5A 85°C 0A 30 20 0.1 10 1 0 100 Contact voltage, V 1 2 3 4 5 Contact current, A 10 80 6 100 120 Coil applied voltage, %V 4-(2). Release time (without diode) 4-(3). Release time (with diode) Sample: ALDP112, 30 pcs. Sample: ALDP112, 30 pcs. Sample: ALDP112, 30 pcs. 10 10 8 8 8 6 4 Release time, ms 10 Release time, ms Operate time, ms 4-(1). Operate time 6 4 6 140 Max. Min. 4 Max. Min. 2 0 60 80 100 120 Coil applied voltage, %V 140 2 0 60 Max. Min. 80 100 120 Coil applied voltage, %V Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –2– 140 2 0 60 80 100 120 Coil applied voltage, %V © Panasonic Corporation 2014 140 ASCTB193E 201402-T LD-P (ALDP1) 5. Electrical life test (5A 250V AC Resistive load) Change of pick-up and drop-out voltage Change of contact resistance 100 10 Contact welding detection and Mis-contacting detection circuit Circuit: 250V AC 12V DC 90 9 8 Pick-up voltage 7 Max. 6 Min. 5 4 3 Drop-out voltage 2 Max. Min. 1 0 0 10 Contact resistance, mΩ Pick-up and drop-out voltage, V Sample: ALDP112, 6 pcs. Operation frequency: 20 times/min. (ON:OFF = 1.5s:1.5s) 80 70 60 50 40 30 20 Max. 10 Min. 0 0 10 No. of operations, ×104 DIMENSIONS (mm inch) The CAD data of the products with a CAD Data No. of operations, ×104 mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions CAD Data PC board pattern (Bottom view) Max. 20.5 Max. .807 Max. 7.2 Max. .283 0.4 .016 Max. 15.3 Max. .602 (1.15) (.045) 11.5 .453 4.7 .185 (1.05) (.041) 1.05 .041 0.2 .008 11.5 .453 7.0 .276 4-1.1 dia. 4-.043 dia. Tolerance: ±0.1 ±.004 3.4 .134 0.4 dia. .016 dia. 7.0 .276 0.8 .031 0.2 .008 4.7 .185 1.15 .045 Schematic (Bottom view) COM NO COIL Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: General tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 SAFETY STANDARDS Certification authority UL/C-UL VDE 5A 277V AC 85°C 185°F, 5A 30V DC 5A 250V AC cosφ = 1.0 85°C 185°F, 5A 30V DC 0ms NOTES 1. For cautions for use, please read “GENERAL APPLICATION GUIDELINES” on page B-1. 2. Usage, transport and storage conditions 1) Temperature: –40 to +85°C –40 to +185°F 2) Humidity: 5 to 85% RH (Avoid freezing and condensation.) The humidity range varies with the temperature. Use within the range indicated in the graph below. 3) Atmospheric pressure: 86 to 106 kPa Temperature and humidity range for usage, transport, and storage Humidity, %RH 85 Tolerance range (Avoid freezing when used at temperatures lower than 0°C 32°F) 5 –40 –40 (Avoid condensation when used at temperatures higher than 0°C 32°F) 0 +32 Temperature, °C °F 3. Certification 1) This relay is UL/C-UL certified. UL/C-UL standards: 5 A 277 V AC 85°C 185°F 5 A 30 V DC Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –3– 85 +185 2) This relay is certified by VDE. VDE standards: 5 A 250 V AC cosφ = 1.0 85°C 185°F 5 A 30 V DC 0ms 3) UL/C-UL and VDE certified ratings are displayed on the packaging box. (On the relay, only the certification marks are shown and not the certified ratings. Please refer to the product specification diagrams to see what is stamped.) 4. Part number display The “W” at the end of the part number only appears on the inner and outer packaging. It does not appear on the relay itself. 5. Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch © Panasonic Corporation 2014 ASCTB193E 201402-T
ALDP109W
物料型号:ALDP系列,具体型号根据额定线圈电压不同,如ALDP105W(5V DC)、ALDP106W(6V DC)、ALDP109W(9V DC)、ALDP112W(12V DC)、ALDP118W(18V DC)、ALDP124W(24V DC)。

器件简介:这是一种额定切换容量为5A 277V AC的小型(7.2mm宽)1表A型功率继电器,具有优秀的耐热性和耐电痕性能,符合RoHS标准。

引脚分配:1表A型触点配置。

参数特性: - 额定线圈电压有多种选择,从5V DC到24V DC。 - 线圈工作电流在不同电压下有所不同,例如5V DC时为40.0mA,24V DC时为8.3mA。 - 线圈电阻和工作功耗随电压变化。 - 绝缘电阻最小值为1000MΩ,击穿电压介于750Vrms到4000Vrms之间。

功能详解:该继电器适用于多种家电和工业设备,如锅炉、空调、冰箱、热水器、微波炉和风扇加热器等。

应用信息:由于其密封型保护结构,适用于需要密封保护的应用场合。

封装信息:该继电器采用纸板包装,每箱100件,每托盘500件。注意,型号末尾的"W"仅出现在内外包装上,不在继电器本身上。

安全标准:符合UL/C-UL和VDE认证,具有不同的工作温度和电压标准。
ALDP109W 价格&库存

很抱歉,暂时无法提供与“ALDP109W”相匹配的价格&库存,您可以联系我们找货

免费人工找货
ALDP109W

    库存:0