Automation Controls Catalog
VDE
Slim (7.2mm .283inch),
1 Form A 5A power relay
LD-P RELAYS (ALDP)
FEATURES
TYPICAL APPLICATIONS
1. Nominal switching capacity:
5A 277V AC
2. Ambient temperature:
–40°C to +85°C –40°F to +185°F
3. Excellent heat resistance and
tracking performance
• Boilers
• Air conditioner
• Refrigerator
• Hot water units
• Microwave ovens
• Fan heaters
EN60695 (GWT2-11, GWFI2-12, GWIT2-13) data
available
(Please consult us for details.)
RoHS compliant
4. Slim type: 20.5 (L) × 7.2 (W) × 15.3
(H) mm .807 (L) × .283 (W) × .602 (H)
inch
Protective construction: Sealed type
ORDERING INFORMATION
ALDP 1
W
LD-P relay
Contact arrangement
1: 1 Form A
Nominal coil voltage (DC)
05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V
Packing style
W: Carton packing
Note: Certified by UL/C-UL and VDE
TYPES
Contact arrangement
1 Form A
Nominal coil voltage
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
Part No.
ALDP105W
ALDP106W
ALDP109W
ALDP112W
ALDP118W
ALDP124W
Packing quantity: Carton 100 pieces, Case 500 pieces
Note: The “W” at the end of the part number only appears on the inner and outer packaging. It does not appear on the relay itself.
Please consult with our sales office on a tube packing type.
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
5V DC
40.0mA
125Ω
6V DC
9V DC
12V DC
18V DC
24V DC
33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
180Ω
405Ω
720Ω
1,620Ω
2,880Ω
2014.02
75%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
industrial.panasonic.com/ac/e/
–1–
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
200mW
130%V of
nominal voltage
© Panasonic Corporation 2014
ASCTB193E 201402-T
LD-P (ALDP1)
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (reference value)*1
Insulation resistance (Initial)
Specifications
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgNi type
5A 277V AC, 3A 30V DC
1,385VA, 90W
277V AC, 30V DC
5A (AC), 3A (DC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts
Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
750 Vrms for 1 min. (Detection current: 10 mA)
4,000 Vrms for 1 min. (Detection current: 10 mA)
Breakdown voltage
(Initial)
Electrical
characteristics
10,000 V
Max. 30°C 86°F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 5A, at 85°C 185°F)
Max. 10 ms (excluding contact bounce time.)
Max. 10 ms (excluding contact bounce time) (With diode)
300 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 5×106
Min. 2×105 (5A 125V AC at rated load), Min. 105 (5A 250V AC, 3A 30V DC)
Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 4 g .14 oz
Temperature rise (coil)
Operate time (at nominal voltage) (at 20°C 68°F)
Release time (at nominal voltage) (at 20°C 68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Electrical (at 20 times/min.) (resistive load)
Shock resistance
Mechanical
characteristics
Expected life
Conditions
Conditions for operation, transport and storage*3
Max. operating speed
Unit weight
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
1. Max. switching power
2. Life curve
3. Coil temperature rise
Sample: ALDP112, 6 pcs.
Point measured: inside the coil
Contact current: 0 A, 5 A
10
50
100
*at room temperature
AC resistive load
Life, ×104
Contact current, A
5
Temperature rise, °C
125V AC resistive load
1
250V AC resistive load
10
5A*
0A*
40
85°C 5A
85°C 0A
30
20
0.1
10
1
0
100
Contact voltage, V
1
2
3
4
5
Contact current, A
10
80
6
100
120
Coil applied voltage, %V
4-(2). Release time (without diode)
4-(3). Release time (with diode)
Sample: ALDP112, 30 pcs.
Sample: ALDP112, 30 pcs.
Sample: ALDP112, 30 pcs.
10
10
8
8
8
6
4
Release time, ms
10
Release time, ms
Operate time, ms
4-(1). Operate time
6
4
6
140
Max.
Min.
4
Max.
Min.
2
0
60
80
100
120
Coil applied voltage, %V
140
2
0
60
Max.
Min.
80
100
120
Coil applied voltage, %V
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–2–
140
2
0
60
80
100
120
Coil applied voltage, %V
© Panasonic Corporation 2014
140
ASCTB193E 201402-T
LD-P (ALDP1)
5. Electrical life test
(5A 250V AC Resistive load)
Change of pick-up and drop-out voltage
Change of contact resistance
100
10
Contact welding
detection and
Mis-contacting
detection circuit
Circuit:
250V AC
12V DC
90
9
8
Pick-up voltage
7
Max.
6
Min.
5
4
3
Drop-out voltage
2
Max.
Min.
1
0
0
10
Contact resistance, mΩ
Pick-up and drop-out voltage, V
Sample: ALDP112, 6 pcs.
Operation frequency: 20 times/min.
(ON:OFF = 1.5s:1.5s)
80
70
60
50
40
30
20
Max.
10
Min.
0
0
10
No. of operations, ×104
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
No. of operations, ×104
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
PC board pattern (Bottom view)
Max. 20.5
Max. .807
Max. 7.2
Max. .283
0.4
.016
Max. 15.3
Max. .602
(1.15)
(.045)
11.5
.453
4.7
.185
(1.05)
(.041)
1.05
.041
0.2
.008
11.5
.453
7.0
.276
4-1.1 dia.
4-.043 dia.
Tolerance: ±0.1 ±.004
3.4
.134
0.4 dia.
.016 dia.
7.0
.276
0.8
.031
0.2
.008
4.7
.185
1.15
.045
Schematic (Bottom view)
COM
NO
COIL
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
SAFETY STANDARDS
Certification authority
UL/C-UL
VDE
5A 277V AC 85°C 185°F, 5A 30V DC
5A 250V AC cosφ = 1.0 85°C 185°F, 5A 30V DC 0ms
NOTES
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES” on page B-1.
2. Usage, transport and storage
conditions
1) Temperature:
–40 to +85°C –40 to +185°F
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage
Humidity, %RH
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
5
–40
–40
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
0
+32
Temperature, °C °F
3. Certification
1) This relay is UL/C-UL certified.
UL/C-UL standards:
5 A 277 V AC 85°C 185°F
5 A 30 V DC
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–3–
85
+185
2) This relay is certified by VDE.
VDE standards:
5 A 250 V AC cosφ = 1.0 85°C 185°F
5 A 30 V DC 0ms
3) UL/C-UL and VDE certified ratings are
displayed on the packaging box.
(On the relay, only the certification marks
are shown and not the certified ratings.
Please refer to the product specification
diagrams to see what is stamped.)
4. Part number display
The “W” at the end of the part number
only appears on the inner and outer
packaging. It does not appear on the
relay itself.
5. Creepage distance and clearances
between contact and coil: Min. 6 mm
.236 inch
© Panasonic Corporation 2014