Load for air conditioner
1 Form A 20A power relays
TMP type
PCB type
RoHS compliant
Protective construction: Flux-resistant
type
LF RELAYS (ALF)
FEATURES
TYPICAL APPLICATIONS
1. Ideal for compressor and inverter
loads
1) Compressor load: 20A 250V AC
2) Inverter load: 20A 100V AC,
10A 200V AC
2. Long insulation distance
• Creepage distance and clearances
between contact and coil;
Creepage Min. 9.5mm .374inch/
Clearance Min. 8mm .315inch
• Surge withstand voltage: 10,000V
3. “PCB” and “TMP” types available
4. Conforms to the various safety
standards:
UL/C-UL, TÜV and VDE approved
1. Air conditioner
2. Refrigerators
3. OA equipment
ORDERING INFORMATION
ALF
1
LF relay
Contact arrangement
1: 1 Form A
Terminal shape
T: TMP type
P: PCB type
Nominal coil voltage, V DC
05: 5, 06: 6, 09: 9, 12: 12, 18: 18, 24: 24
Note: Certified by UL/C-UL,VDE and TÜV
TYPES
Contact arrangement
Nominal coil voltage
1 Form A
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
Part No.
TMP type
ALF1T05
ALF1T06
ALF1T09
ALF1T12
ALF1T18
ALF1T24
PCB type
ALF1P05
ALF1P06
ALF1P09
ALF1P12
ALF1P18
ALF1P24
–1–
ASCTB195E 201606-T
Standard packing: Carton 50 pcs., Case 200 pcs.
LF (ALF)
RATING
1. Coil data
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
5V DC
180 mA
27.8Ω
6V DC
9V DC
12V DC
18V DC
24V DC
150 mA
100 mA
75 mA
50 mA
37.5mA
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
40
90
160
360
640
Nominal operating
power
(at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
900mW
110%V of
nominal voltage
Ω
Ω
Ω
Ω
Ω
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (reference value)*1
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts
Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
1,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
Breakdown voltage
(Initial)
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Specifications
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
20A 250V AC
6,250VA
250V AC
25A
900mW
100mA, 5V DC
Functional
Shock resistance
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Electrical (at 20 times/min.)
Conditions for operation, transport and storage*3
Max. operating speed
Unit weight
10,000 V
Max. 20 ms (excluding contact bounce time.)
Max. 15 ms (excluding contact bounce time) (With diode)
100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 2×106
Min. 105 (resistive load)
Ambient temperature: –40°C to +60°C –40°F to +140°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 23 g .81 oz
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Switching capacity
20 A, 250 V AC (cosφ = 1)
Resistive load
25 A, 250 V AC (cosφ = 1)
Electrical Life
Compressor load
Inverter load
Inrush 70 A (cosφ = 0.7), Steady 20 A (cosφ = 0.9)
250 V AC
Inrush 200 A, Steady 20 A
100 V AC
Inrush 100 A, Steady 10 A
200 V AC
–2–
Min. 105
(at 20 times/min.)
Min. 104
(at 20 times/min.)
Min. 105
(at 20 times/min.)
Min. 3×104
(at 10 times/min.)
Min. 3×104
(at 10 times/min.)
ASCTB195E 201606-T
LF (ALF)
REFERENCE DATA
Sample: ALF1T12, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C 77°F, 60°C 140°F
Contact current: 20A
Temperature rise, °C °F
70
158
25°C 77°F
60°C 140°F
60
140
2-(1). 200V AC electrical life test
(200V AC, inverter load)
Sample: ALF1T12, 6 pcs.
Load: Inrush 102A (wave peak value),
Steady 14.4A (wave peak value)
Inverter dummy 200V AC
Switching frequency: ON 1s, OFF 5s
Circuit:
12
Pick-up and drop-out voltage, V
1. Coil temperature rise
50
122
LF relay contact
40
104
30
86
200V AC
2,000μF
1.9Ω
20
68
10
50
80
100
10
Pick-up voltage
Max.
x
Min.
8
6
Drop-out voltage
Max.
x
4
Min.
2
Switch
0
32
Contact welding: 0 times
Miscontact: 0 times
0
120
0
3
6
No. of operations, ×104
Coil applied voltage, %V
2-(2). 100V AC electrical life test
(100V AC, inverter load)
Sample: ALF1T12, 6 pcs.
Load: Inrush 224A (wave peak value),
Steady 30.5A (wave peak value)
Inverter dummy 100V AC
Switching frequency: ON 1s, OFF 5s
Circuit:
LF relay contact
470μF
2,000μF
100V AC
470μF
Pick-up and drop-out voltage, V
12
Contact welding: 0 times
Miscontact: 0 times
10
Pick-up voltage
8
Max.
x
6
Min.
Drop-out voltage
Max.
x
Min.
4
2
0
0
3
6
No. of operations, ×104
2-(3). Inrush 70.7A, Steady 20A, 250V AC
electrical life test (Compressor dummy load)
2-(4). Electrical life test
(20A 250V AC, resistive load)
Sample: ALF1T12, 6 pcs.
Load: Inrush 70.7A, cosφ = 0.7
Steady 20A, cosφ 0.9
250V AC compressor dummy
Switching frequency: ON 1.5s, OFF 1.5s
Circuit:
Sample: ALF1T12, 6 pcs.
Switching frequency: ON 1.5s, OFF 1.5s
Mg
250V AC
(–)
60Hz
12V DC
SW1
(+)
Detection
Circuit
Contact Weld
Min. 0.5s
Miss Contact
after 0.2s
12
Contact welding: 0 times
Miscontact: 0 times
10
8
Pick-up voltage
Max.
x
Min.
6
4
Max.
x
Min.
Drop-out voltage
G
2
0
Pick-up and drop-out voltage, V
NO
Pick-up and drop-out voltage, V
COM
12
Contact welding: 0 times
Miscontact: 0 times
10
Pick-up voltage
8
Max.
x
Min.
6
Drop-out voltage
Max.
x
4
Min.
2
0
5
No. of operations,
–3–
10
×104
0
0
10
No. of operations, ×104
ASCTB195E 201606-T
20
LF (ALF)
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. TMP type
External dimensions
CAD Data
11.25
.443
0.8
.031
PC board pattern (Bottom view)
27.6 ±0.1
1.087 ±.004
6.4
.252
12.8
.504
0.8
.031
#250 terminal
2.0
.079
7.9
10.2 .311
.401
13.8 ±0.1
.543 ±.004
2
.0 dia.
79
dia
.
a.
di ia.
d
9
7
2
.0
12.0 ±0.1
.472 ±.004
23.3
.917
0.5
.020
Lot No.
0.8
.031
1.6
.063
22.0
.866
27.6
1.087
1.6
.063
a.
di ia.
8 d
1. 71
0
.
±0.1
12.0
.472 ±.004
±0.1
10.0
.394 ±.004
Tolerance: ±0.1 ±.004
4.0
.157
0.8
.031
1.6
.063
1
.07 .8 d
1 d ia.
ia.
Schematic (Bottom view)
0.3
.012
12.0
.472
FASTON 250
30.1
1.185
3 NO COM 4
15.7
.618
NO
1
COM
PC board side
2
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
2. PCB type
External dimensions
CAD Data
PC board pattern (Bottom view)
27.6 ±0.1
1.087 ±.004
23.3
.917
2
.0 dia.
79
dia
13.8 ±0.1
.543 ±.004
a.
di ia.
d
79
2
.0
.
0.5
.020
Lot No.
0.8
.031
1.6
.063
22.0
.866
27.6
1.087
1.6
.063
0.8
.031
12.0 ±0.1
.472 ±.004
4.0
.157
1.6
.063
0.3
.012
12.0
.472
a.
di ia.
8 d
1. 71
.0
12.0 ±0.1
.472 ±.004
30.1
1.185
10.0 ±0.1
.394 ±.004
1
.07 .8 d
1 d ia.
ia.
Tolerance: ±0.1 ±.004
3 NO COM 4
Schematic (Bottom view)
15.7
.618
NO
1
COM
2
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
SAFETY STANDARDS
UL/C-UL (Recognized)
VDE (Certified)
File No. Contact rating
Temp.
Cycles File No.
Contact rating
Temp.
Cycles
File No.
E43028 25A 277V AC 40°C 104°F 6 × 103 40009169 20A 250V AC (cosφ =1.0) 60°C 140°F 104 B 12 06 13461 326
20A 277V AC 40°C 104°F 105
—
—
—
—
TÜV (Certified)
Contact rating
Temp.
20A 250V AC (cosφ =1.0) 60°C 140°F
—
—
TV rating (UL)
Cycles File No. Contact rating
104
—
E43028 TV-8
—
—
* CSA standard: Certified by C-UL
–4–
ASCTB195E 201606-T
LF (ALF)
EN/IEC VDE Certified
INSULATION CHARACTERISTIC (IEC61810-1)
Item
Clearance/Creepage distance (IEC61810-1)
Category of protection (IEC61810-1)
Tracking resistance (IEC60112)
Insulation material group
Over voltage category
Rated voltage
Pollution degree
Type of insulation (Between contact and coil)
Type of insulation (Between open contacts)
Characteristic
Min. 5.5mm/5.5mm
RT II
PTI 175
III a
III
250V
2
Reinforced insulation
Micro disconnection
NOTES
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
–5–