Automation Controls Catalog
To Be Discontinued:
Last time buy:March 31, 2015
MINIATURE SWITCHES
WITH HIGH PRECISION
AM5 (QV)
SWITCHES
FEATURES
• High precision as a result of designing ideal spring by
using computer analysis
O.P. 14.7±0.4mm
• Reliable design with shock resistance min. 980 m/s2
• High inrush resistance 160A
• Wide variety of contact ratings and terminal types
• UL/C-UL, ENEC/VDE approved
• Protection grade: IP40
27.8
15.9
10.3
TYPICAL APPLICATION
• Home appliances
• Vending machines
• Amusement and communication equipment
• Copies
• General industrial machines
Standard type contact gap is 1mm. Please consult us if you
need more than 1mm contact gap.
RoHS compliant
CONSTRUCTION
1. Ag alloy contact
2. Au-clad contact
CONTACT ARRANGEMENT
NC
NO
COM
2014.03
industrial.panasonic.com/ac/e/
–1–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
TERMINALS
.187 Quick-connect terminal
.187 Quick-connect/solder terminal
Bottom COM terminal
.250 Quick-connect terminal
Bottom COM terminal
NC
1
2
1
3
2
3
NC
NO
C
NO
C
Side COM terminal
Side COM terminal
NC
NC
2
1
3
1
NO
2
3
NO
C
C
Dimensions
.187 Quick-connect terminal
Dimensions
1.55 dia.
1.65 +0.1
0 dia.
4.75 6.4
6.35 +0.05
–0.07
4.15 ±0.15
3.2
6.35
2
8.05 +0.1
–0.05
Dimensions
.187 Quick-connect/solder terminal
R1.2
1.2
R0.8
4.75 6.4
3.2
6.35
OPERATION FORCE CHART
Actuator
7th digit of Part Number
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
3
0.49N
0.59N
0.29N
0.15N
0.29N
0.59N
0.29N
4
0.98N
1.08N
0.59N
0.29N
0.59N
1.08N
0.59N
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–2–
Operation Force, Max. by actuator
5
1.96N
2.16N
1.18N
0.59N
1.18N
2.16N
1.18N
6
2.94N
3.14N
1.77N
0.88N
1.77N
3.14N
1.77N
© Panasonic Corporation 2014
7
3.92N
4.12N
2.35N
1.18N
2.35N
4.12N
2.35N
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
ORDERING INFORMATION
0.1A type
Ex. AM5
Type of
switch
AM5:
QV switch
0
0
1
Contact rating
Terminals
00: 0.1 A (AgNi alloy
+ Au-clad)
1: Bottom COM, SPDT
2: Bottom COM, SPST-NC
3: Bottom COM, SPST-NO
4: Side COM, SPDT
5: Side COM, SPST-NC
6: Side COM, SPST-NO
0
C
5
3
Actuators
Terminals
0: Pin plunger
A: .187 Quick-connect/solder terminal
1: Short hinge lever
C: .187 Quick-connect terminal
2: Hinge lever
3: Long hinge lever
4: Simulated roller lever
5: Short roller lever
6: Roller lever
Remarks: 1. Not every combination is available. Please refer to the table, “PRODUCT TYPES”.
2. Please refer to the Standard Chart regarding Agency Standard
Operating force by
pin plunger (max.)
3: 0.49 N
4: 0.98 N
5: 1.96 N
Agency
standard
3: UL/C-UL
rated,
ENEC/VDE
approved
Operating force by
pin plunger (max.)
3: 0.49 N
Agency
standard
3: UL/C-UL
rated,
ENEC/VDE
approved
6A type
Ex. AM5
Type of
switch
AM5:
QV switch
0
6
1
Contact rating
Terminals
06: 6 A (AgNi alloy)
1: Bottom COM, SPDT
2: Bottom COM, SPST-NC
3: Bottom COM, SPST-NO
4: Side COM, SPDT
5: Side COM, SPST-NC
6: Side COM, SPST-NO
0
C
5
3
Actuators
Terminals
0: Pin plunger
A: .187 Quick-connect/solder terminal
1: Short hinge lever
C: .187 Quick-connect terminal
2: Hinge lever
3: Long hinge lever
4: Simulated roller lever
5: Short roller lever
6: Roller lever
Remarks: 1. Not every combination is available. Please refer to the table, “PRODUCT TYPES”.
2. Please refer to the Standard Chart regarding Agency Standard
11A type
Ex. AM5
1
1
1
0
C
4
3
N
Operating force
Agency
Contact
by pin plunger
standard
(max.)
AM5:
11: 11 A
1: Bottom COM, SPDT
0: Pin plunger
A: .187 Quick-connect/solder terminal
4: 0.98 N
3: UL/C-UL N: Cadmium
QV switch
(AgSnO2
2: Bottom COM, SPST-NC 1: Short hinge lever
C: .187 Quick-connect terminal
rated,
free
alloy)
3: Bottom COM, SPST-NO 2: Hinge lever
D: .250 Quick-connect terminal
ENEC/
4: Side COM, SPDT
3: Long hinge lever
VDE
5: Side COM, SPST-NC
4: Simulated roller lever
approved
6: Side COM, SPST-NO
5: Short roller lever
6: Roller lever
Remarks: 1. Not every combination is available. Please refer to the table, “PRODUCT TYPES”.
2. Please refer to the Standard Chart regarding Agency Standard
Type of
switch
Contact rating
Terminals
Actuators
Terminals
16A type
Ex. AM5
1
6
1
0
C
5
3
N
Operating force
Agency
Contact
by pin plunger
standard
(max.)
AM5:
16: 16 A
1: Bottom COM, SPDT
0: Pin plunger
A: .187 Quick-connect/solder terminal
5: 1.96 N
3: UL/C-UL N: Cadmium
QV switch
(AgSnO2
2: Bottom COM, SPST-NC 1: Short hinge lever
C: .187 Quick-connect terminal
6: 2.94 N
rated,
free
alloy)
3: Bottom COM, SPST-NO 2: Hinge lever
D: .250 Quick-connect terminal
7: 3.92 N
ENEC/
4: Side COM, SPDT
3: Long hinge lever
VDE
5: Side COM, SPST-NC
4: Simulated roller lever
approved
6: Side COM, SPST-NO
5: Short roller lever
6: Roller lever
Remarks: 1. Not every combination is available. Please refer to the table, “PRODUCT TYPES”.
2. Please refer to the Standard Chart regarding Agency Standard
Type of
switch
Contact rating
Terminals
Actuators
Terminals
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–3–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
PRODUCT TYPES
0.1A type (AgNi alloy + Au-clad contact)
.187 Quick-connect terminal
1) Bottom COM terminal
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
Operating force, Max.
0.49N
0.98N
1.96N
0.59N
1.08N
2.16N
0.29N
0.59N
1.18N
0.15N
0.29N
0.59N
0.29N
0.59N
1.18N
0.59N
1.08N
2.16N
0.29N
0.59N
1.18N
Contact arrangement
SPDT
AM50010C33
AM50010C43
AM50010C53
AM50011C33
AM50011C43
AM50011C53
AM50012C33
AM50012C43
AM50012C53
AM50013C33
AM50013C43
AM50013C53
AM50014C33
AM50014C43
AM50014C53
AM50015C33
AM50015C43
AM50015C53
AM50016C33
AM50016C43
AM50016C53
Contact arrangement
SPST-NC
SPST-NO
AM50020C33
AM50030C33
AM50020C43
AM50030C43
AM50020C53
AM50030C53
AM50021C33
AM50031C33
AM50021C43
AM50031C43
AM50021C53
AM50031C53
AM50022C33
AM50032C33
AM50022C43
AM50032C43
AM50022C53
AM50032C53
AM50023C33
AM50033C33
AM50023C43
AM50033C43
AM50023C53
AM50033C53
AM50024C33
AM50034C33
AM50024C43
AM50034C43
AM50024C53
AM50034C53
AM50025C33
AM50035C33
AM50025C43
AM50035C43
AM50025C53
AM50035C53
AM50026C33
AM50036C33
AM50026C43
AM50036C43
AM50026C53
AM50036C53
Contact arrangement
SPDT
AM50040C33
AM50040C43
AM50040C53
AM50041C33
AM50041C43
AM50041C53
AM50042C33
AM50042C43
AM50042C53
AM50043C33
AM50043C43
AM50043C53
AM50044C33
AM50044C43
AM50044C53
AM50045C33
AM50045C43
AM50045C53
AM50046C33
AM50046C43
AM50046C53
Contact arrangement
SPST-NC
SPST-NO
AM50050C33
AM50060C33
AM50050C43
AM50060C43
AM50050C53
AM50060C53
AM50051C33
AM50061C33
AM50051C43
AM50061C43
AM50051C53
AM50061C53
AM50052C33
AM50062C33
AM50052C43
AM50062C43
AM50052C53
AM50062C53
AM50053C33
AM50063C33
AM50053C43
AM50063C43
AM50053C53
AM50063C53
AM50054C33
AM50064C33
AM50054C43
AM50064C43
AM50054C53
AM50064C53
AM50055C33
AM50065C33
AM50055C43
AM50065C43
AM50055C53
AM50065C53
AM50056C33
AM50066C33
AM50056C43
AM50066C43
AM50056C53
AM50066C53
2) Side COM terminal
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
Operating force, Max.
0.49N
0.98N
1.96N
0.59N
1.08N
2.16N
0.29N
0.59N
1.18N
0.15N
0.29N
0.59N
0.29N
0.59N
1.18N
0.59N
1.08N
2.16N
0.29N
0.59N
1.18N
Remark: Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
.187 Quick-connect terminal .187 Quick-connect/solder terminal
AM50010C33
→
AM50010A33
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–4–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
6A type (AgNi alloy contact)
.187 Quick-connect terminal
1) Bottom COM terminal
Actuator
Operating force, Max.
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
0.49N
0.59N
0.29N
0.15N
0.29N
0.59N
0.29N
Contact arrangement
SPDT
AM50610C33
AM50611C33
AM50612C33
AM50613C33
AM50614C33
AM50615C33
AM50616C33
Contact arrangement
SPST-NC
SPST-NO
AM50620C33
AM50630C33
AM50621C33
AM50631C33
AM50622C33
AM50632C33
AM50623C33
AM50633C33
AM50624C33
AM50634C33
AM50625C33
AM50635C33
AM50626C33
AM50636C33
Contact arrangement
SPDT
AM50640C33
AM50641C33
AM50642C33
AM50643C33
AM50644C33
AM50645C33
AM50646C33
Contact arrangement
SPST-NC
SPST-NO
AM50650C33
AM50660C33
AM50651C33
AM50661C33
AM50652C33
AM50662C33
AM50653C33
AM50663C33
AM50654C33
AM50664C33
AM50655C33
AM50665C33
AM50656C33
AM50666C33
2) Side COM terminal
Actuator
Operating force, Max.
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
0.49N
0.59N
0.29N
0.15N
0.29N
0.59N
0.29N
Remarks: Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
.187 Quick-connect terminal .187 Quick-connect/solder terminal
AM50610C33
→
AM50610A33
11A type (AgSnO2 alloy contact)
.187 Quick-connect terminal
1) Bottom COM terminal
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
Operating force, Max.
0.98N
1.08N
0.59N
0.29N
0.59N
1.08N
0.59N
Contact arrangement
SPDT
AM51110C43N
AM51111C43N
AM51112C43N
AM51113C43N
AM51114C43N
AM51115C43N
AM51116C43N
Contact arrangement
SPST-NC
SPST-NO
AM51120C43N
AM51130C43N
AM51121C43N
AM51131C43N
AM51122C43N
AM51132C43N
AM51123C43N
AM51133C43N
AM51124C43N
AM51134C43N
AM51125C43N
AM51135C43N
AM51126C43N
AM51136C43N
Contact arrangement
SPDT
AM51140C43N
AM51141C43N
AM51142C43N
AM51143C43N
AM51144C43N
AM51145C43N
AM51146C43N
Contact arrangement
SPST-NC
SPST-NO
AM51150C43N
AM51160C43N
AM51151C43N
AM51161C43N
AM51152C43N
AM51162C43N
AM51153C43N
AM51163C43N
AM51154C43N
AM51164C43N
AM51155C43N
AM51165C43N
AM51156C43N
AM51166C43N
2) Side COM terminal
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
Operating force, Max.
0.98N
1.08N
0.59N
0.29N
0.59N
1.08N
0.59N
Remarks: 1. Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
.187 Quick-connect terminal .187 Quick-connect/solder terminal
AM51110C43N
→
AM51110A43N
2. .250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D.
.187 Quick-connect terminal .250 Quick-connect terminal
AM51110C43N
→
AM51110D43N
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–5–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
16A type (AgSnO2 alloy contact)
.187 Quick-connect terminal
1) Bottom COM terminal
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
Operating force, Max.
1.96N
2.94N
3.92N
2.16N
3.14N
4.12N
1.18N
1.77N
2.35N
0.59N
0.88N
1.18N
1.18N
1.77N
2.35N
1.18N
3.14N
4.12N
1.18N
1.77N
2.35N
Contact arrangement
SPDT
AM51610C53N
AM51610C63N
AM51610C73N
AM51611C53N
AM51611C63N
AM51611C73N
AM51612C53N
AM51612C63N
AM51612C73N
AM51613C53N
AM51613C63N
AM51613C73N
AM51614C53N
AM51614C63N
AM51614C73N
AM51615C53N
AM51615C63N
AM51615C73N
AM51616C53N
AM51616C63N
AM51616C73N
Contact arrangement
SPST-NC
SPST-NO
AM51620C53N
AM51630C53N
AM51620C63N
AM51630C63N
AM51620C73N
AM51630C73N
AM51621C53N
AM51631C53N
AM51621C63N
AM51631C63N
AM51621C73N
AM51631C73N
AM51622C53N
AM51632C53N
AM51622C63N
AM51632C63N
AM51622C73N
AM51632C73N
AM51623C53N
AM51633C53N
AM51623C63N
AM51633C63N
AM51623C73N
AM51633C73N
AM51624C53N
AM51634C53N
AM51624C63N
AM51634C63N
AM51624C73N
AM51634C73N
AM51625C53N
AM51635C53N
AM51625C63N
AM51635C63N
AM51625C73N
AM51635C73N
AM51626C53N
AM51636C53N
AM51626C63N
AM51636C63N
AM51626C73N
AM51636C73N
Contact arrangement
SPDT
AM51640C53N
AM51640C63N
AM51640C73N
AM51641C53N
AM51641C63N
AM51641C73N
AM51642C53N
AM51642C63N
AM51642C73N
AM51643C53N
AM51643C63N
AM51643C73N
AM51644C53N
AM51644C63N
AM51644C73N
AM51645C53N
AM51645C63N
AM51645C73N
AM51646C53N
AM51646C63N
AM51646C73N
Contact arrangement
SPST-NC
SPST-NO
AM51650C53N
AM51660C53N
AM51650C63N
AM51660C63N
AM51650C73N
AM51660C73N
AM51651C53N
AM51661C53N
AM51651C63N
AM51661C63N
AM51651C73N
AM51661C73N
AM51652C53N
AM51662C53N
AM51652C63N
AM51662C63N
AM51652C73N
AM51662C73N
AM51653C53N
AM51663C53N
AM51653C63N
AM51663C63N
AM51653C73N
AM51663C73N
AM51654C53N
AM51664C53N
AM51654C63N
AM51664C63N
AM51654C73N
AM51664C73N
AM51655C53N
AM51665C53N
AM51655C63N
AM51665C63N
AM51655C73N
AM51665C73N
AM51656C53N
AM51666C53N
AM51656C63N
AM51666C63N
AM51656C73N
AM51666C73N
2) Side COM terminal
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short roller lever
Roller lever
Operating force, Max.
1.96N
2.94N
3.92N
2.16N
3.14N
4.12N
1.18N
1.77N
2.35N
0.59N
0.88N
1.18N
1.18N
1.77N
2.35N
2.16N
3.14N
4.12N
1.18N
1.77N
2.35N
Remarks: 1. Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
.187 Quick-connect terminal .187 Quick-connect/solder terminal
AM51610C53N
→
AM51610A53N
2. .250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D.
.187 Quick-connect terminal .250 Quick-connect terminal
AM51610C53N
→
AM51610D53N
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–6–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
DATA
Au-clad type
Range of low-level current and voltage (Reference only)
Current (mA)
500
100
50
10
5
2
1
4
8
12
16
20
24
DC voltage (V)
SPECIFICATIONS
1. Contact rating
Type
AgNi alloy + Au-clad
contact
0.1A type
AgNi alloy contact
6A type
11A type
AgSnO2 alloy contact
16A type
AgNi alloy + Au-clad contact for low level
circuit
Voltage
Resistive load
(cos φ = 1)
Inductive load
(cos φ ] 0.6 to 0.7)
250V AC
125V AC
30V DC
250V AC
125V AC
125V DC
250V AC
125V AC
125V DC
250V AC
125V AC
125V DC
6V DC
12V DC
24V DC
0.1A
0.1A
0.1A
6A
6A
0.5A
11A
11A
0.6A
16A
16A
0.6A
5mA
2mA
1mA
0.1A
0.1A
0.1A
3A
3A
0.5A
6A
6A
0.6A
10A
10A
0.6A
—
—
—
Remark: The inductive load for DC should have a time constant of 7 ms or less.
2. Characteristics
Type
Expected life
(min.)
16, 11, 6A type
Electrical
105 operations (at rated load)
2 × 106 operations (at low-level circuit rating)
100MΩ (at 500V DC)
1,000Vrms for 1 min.
105 Operations (at rated load 20 cpm)
Insulation resistance
Between terminals
Dielectric
Between terminals and other
strength
exposed metal parts
Between terminals and ground
Contact resistance (initial)
Vibration resistance (by pin plunger)
Shock resistance (by pin plunger)
(contact opening: max. 1msec.)
Allowable operating speed
Maximum operating cycle rate
Ambient temperature
Weight
Contact material
0.1A type
107 operations (at 60 cpm)
Mechanical
2,000Vrms for 1 min.
2,000Vrms for 1 min.
50mΩ (by voltage drop at 1A 6 to 8V DC)
50mΩ (by voltage drop at 0.1A 6 to 8V DC)
10 to 55Hz at simple amplitude of 0.75mm (Contact opening: max. 1msec.)
O.F. 0.49N max. type Min. 98m/s2
O.F. 0.49N max. type Min. 98m/s2
O.F. 0.98N max. type Min. 196m/s2
O.F. 0.98N max. type Min. 196m/s2
O.F. 1.96N to 3.92N max. type Min. 294m/s2
O.F. 1.96N max. type Min. 294m/s2
0.1 to 1,000mm/sec. (at pin plunger)
600cpm
–25 to +105°C (Not freezing below 0°C)
Approx. 6.3g
6A type: AgNi alloy,
11A and 16A type: AgSnO2 alloy
AgNi alloy + Au-clad
Remarks: 1. Test conditions and judgement are in accordance with NECA C 4505.
2. OF: Value of pin plunger
3. When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly
depending on the load capacity. Please consult us.
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–7–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
3. Operating characteristics
1) Pin plunger
7th digit of part No.
Operating force, max.
Release force, min.
Pretravel, max. mm
Movement differential, max. mm
Overtravel, min. mm
Operating position mm
3
0.49N
0.12N
4
0.98N
0.25N
5
1.96N
0.49N
1.4
0.4
1.0
14.7±0.4
6
2.94N
0.74N
7
3.92N
0.98N
3
0.59N
0.098N
4
1.08N
0.20N
5
2.16N
0.39N
1.6
0.5
0.9
15.3±0.5
6
3.14N
0.59N
7
4.12N
0.78N
3
0.29N
0.049N
4
0.59N
0.098N
5
1.18N
0.20N
3.2
1.0
1.4
15.3±1.0
6
1.77N
0.29N
7
2.35N
0.39N
3
0.15N
0.025N
4
0.29N
0.049N
5
0.59N
0.098N
7.5
2.0
2.2
15.3±2.6
6
0.88N
0.15N
7
1.18N
0.20N
3
0.29N
0.049N
4
0.59N
0.098N
5
1.18N
0.20N
3.2
1.0
1.4
18.5±1.0
6
1.77N
0.29N
7
2.35N
0.39N
3
0.59N
0.098N
4
1.08N
0.20N
5
2.16N
0.39N
1.6
0.5
0.9
20.7±0.5
6
3.14N
0.59N
7
4.12N
0.78N
3
0.29N
0.049N
4
0.59N
0.098N
5
1.18N
0.20N
3.2
1.0
1.4
20.7±1.0
6
1.77N
0.29N
7
2.35N
0.39N
2) Short hinge lever
7th digit of part No.
Operating force, max.
Release force, min.
Pretravel, max. mm
Movement differential, max. mm
Overtravel, min. mm
Operating position mm
3) Hinge lever
7th digit of part No.
Operating force, max.
Release force, min.
Pretravel, max. mm
Movement differential, max. mm
Overtravel, min. mm
Operating position mm
4) Long hinge lever
7th digit of part No.
Operating force, max.
Release force, min.
Pretravel, max. mm
Movement differential, max. mm
Overtravel, min. mm
Operating position mm
5) Simulated roller lever
7th digit of part No.
Operating force, max.
Release force, min.
Pretravel, max. mm
Movement differential, max. mm
Overtravel, min. mm
Operating position mm
6) Short roller lever
7th digit of part No.
Operating force, max.
Release force, min.
Pretravel, max. mm
Movement differential, max. mm
Overtravel, min. mm
Operating position mm
7) Roller lever
7th digit of part No.
Operating force, max.
Release force, min.
Pretravel, max. mm
Movement differential, max. mm
Overtravel, min. mm
Operating position mm
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–8–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
DIMENSIONS
mm General tolerance: ±0.25
1. Pin plunger
Bottom COM terminal
.187 Quick-connect terminal
.250 Quick-connect terminal
1.55 dia.
1.65 +0.1
dia.
0
6.35 +0.05
–0.07
6.4
4.75
3.2
2
6.35
1.8
27.8
20.2
2.8
(P.T.)
1.4 max.
3.95
3.1 +0.25
–0.05 dia.
2.8
4.1 5.65
(O.P.)
14.7 ±0.4 15.9 10.3 ±0.1
NC
0.5
2
1
C
2.8
13.5
+0.25
3.1 –0.05
NC
2.8
10.3
22.2 ±0.1
3
3.4 ±0.15
+0.25
3.1 –0.05
3.95
0.8 9.3 10.6
2
C
6.65
3.4 ±0.15
3.1 +0.25
–0.05 dia.
4.1 3.6
1
NO
3
2.8
(O.P.)
14.7 ±0.4 15.9 10.3 ±0.1
6.5
9.3
1.8
27.8
20.2
2.8
NO
12° ±1
(P.T.)
1.4 max.
4.15 ±0.15
8.05 +0.1
-0.05
9.7
22.2 ±0.1
39.45
10.3
42.7
Side COM terminal
.187 Quick-connect terminal
.250 Quick-connect terminal
1.55 dia.
1.65 +0.1
dia.
0
6.35 +0.05
–0.07
6.4
4.75
3.2
2
6.35
(P.T.)
1.4 max.
3.1 +0.25
–0.05 dia.
2.8
2.8
(O.P.)
14.7 ±0.4 15.9 10.3 ±0.1
NC
0.5
2
1
3
4.1
5.65
9.3
6.5
+0.25
3.1 –0.05
3.95
2.8
3.1 +0.25
–0.05 dia.
NC
2
1
3
NO
0.8 9.3 10.6
C
6
2.8
±0.1
3.4 ±0.15
3.1 +0.25
–0.05
10.3
9.8
22.2 ±0.1
10.3
42.7
39.45
2. Short hinge lever
1.55 dia.
6.4
4.75
3.2
6.35
22.1 ±0.5
27.8
20.2
(P.T.)
1.6 max.
1.8
5.0
4.1 5.65
NC
2
1
3
3.4 ±0.15
+0.25
–0.05
22.2
9.3
6.5
6.65
13.5
±0.1
0.5
NO
C
3.1
3.1 +0.25
–0.05 dia.
2.8
(O.P.)
15.3 ±0.5 15.9 10.3 ±0.1
2.8
10.3
39.45
The dimensions other than drawn above are same as pin plunger type.
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–9–
3.95
4.1 3.6
(O.P.)
14.7 ±0.4 15.9 10.3 ±0.1
3.4 ±0.15
22.2
1.8
27.8
20.2
2.8
NO
C
2.8
(P.T.)
1.4 max.
1.8
27.8
20.2
4.15
8.05 +0.1
-0.05
±0.15
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
mm General tolerance: ±0.25
3. Hinge lever
1.55 dia.
6.4
4.75
3.2
6.35
35.8 ±0.5
27.8
20.2
(P.T.)
3.2 max.
1.8
4.1 5.65
(O.P.)
15.3 ±1.0 15.9 10.3 ±0.1
NC
0.5
2
1
6.5
9.3
NO
3
C
2.8
6.65
3.4 ±0.15
+0.25
3.1 −0.05
5.0
3.1 +0.25
−0.05 dia.
2.8
13.5
10.3
22.2 ±0.1
39.45
The dimensions other than drawn above are same as pin plunger type.
4. Long hinge lever
1.55 dia.
6.4
4.75
3.2
(P.T.)
7.5 max.
6.35
59.5 ±0.5
1.8
27.8
20.2
5.0
3.1 +0.25
–0.05 dia.
2.8
4.1 5.65
(O.P.)
15.3 ±2.6
15.9 10.3 ±0.1
NC
3.1 +0.25
–0.05
0.5
2
1
9.3
2.8
6.5
NO
3
C
6.65
3.4 ±0.15
13.5
10.3
22.2 ±0.1
39.45
The dimensions other than drawn above are same as pin plunger type.
5. Simulated roller lever
1.55 dia.
6.4
4.75
3.2
6.35
(P.T.)
3.2 max.
32.8
R3
(O.P.)
18.5 ±1.0
5.0
±0.5
1.8
27.8
20.2
3.1 +0.25
–0.05 dia.
2.8
4.1 5.65
15.9 10.3 ±0.1
NC
2
1
3
+0.25
3.1 –0.05
3.4 ±0.15
6.5
6.65
13.5
22.2 ±0.1
9.3
NO
C
2.8
0.5
10.3
39.45
The dimensions other than drawn above are same as pin plunger type.
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–10–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
mm General tolerance: ±0.25
6. Short roller lever
1.55 dia.
6.4
4.75
3.2
6.35
20.6 ±0.5
27.8
20.2
(P.T.)
1.6 max.
4.9
1.8
2.8
4.8
3.1 +0.25
–0.05 dia.
(O.P.)
20.7 ±0.5
4.1 5.65
15.9 10.3 ±0.1
NC
0.5
2
1
9.3
2.8
6.65
3.4 ±0.15
+0.25
3.1 –0.05
6.5
NO
3
C
13.5
10.3
22.2 ±0.1
39.45
The dimensions other than drawn above are same as pin plunger type.
7. Hinge Roller lever
1.55 dia.
6.4
3.2
(P.T.)
3.2 max.
4.75
6.35
34.2 ±0.5
4.9
1.8
27.8
20.2
2.8
4.8
3.1 +0.25
–0.05 dia.
(O.P.)
20.7 ±1.0
4.1 5.65
15.9 10.3 ±0.1
NC
2
1
3
2.8
3.4 ±0.15
9.3
6.5
6.65
13.5
22.2 ±0.1
+0.25
3.1 –0.05
0.5
NO
C
10.3
39.45
The dimensions other than drawn above are same as pin plunger type.
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–11–
© Panasonic Corporation 2014
AECTB9E 201403-T
To Be Discontinued
Last time buy: March 31, 2015
AM5
NOTES
1. Fastening of the switch body
1) Use flat filister head M3 screws to
mount switches with less than a 0.49
N·m torque. Use of screws washers or
adhesive lock is recommended to
prevent loosening of the screws.
2) Check insulation distance between
ground and each terminal.
3) When the operation object is in the
free position, force should not be applied
directly to the actuator or pin plunger.
Also force should be applied to the pin
plunger from vertical direction to the
switch.
4) The standard value of overtravel
should be the range of 70% to 100% of
the rated O.T. value.
2. Soldering operations
Manual soldering should be
accomplished within 5 seconds, with
max. 350°C iron. Care should be taken
not to apply force to the terminal during
soldering.
Terminal portions must not be moved in
min.1 minute after soldering.
Also no tensile strength of lead wires
should be applied to terminals.
3. Varience of operating
characteristics
When specifying the switch, allow +20%
to the listed operating and release
forces.
USE OF CONNECTOR
4. Environment
Avoid using the switches in the following
conditions;
• In corrosive gases, such as silicon gas
• In a dusty environment
5. For switching of inductive loads
(relays, solenoids, etc.)
1) In order to prevent damage to
contacts due to the occurrence of arcing,
an arc absorbing circuit should be
applied.
2) Care should be taken that occurrence
in AC load possibly shorten the expected
life.
6. Please assure the quality and
reliability of the switch under the
actual service condition.
7. It is recommended to use Au-clad
contact type in use of low-level circuit
rating.
8. Cover and body are press-fitted.
Once it is taken apart, it may cause
change of characteristics.
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
–12–
The .187 Quick-connect terminal and
.250 Quick-connect terminal accept the
all kinds of 1 polarity connectors and the
“Positive Lock” connectors
Please contact the manufacturers
directly.
• receptacle terminal
.250 series
.187 series
• “Positive Lock” connector. (equipped
with the lock construction of low
insertion type)
.187 type
.187 type
(1 polarity)
(2 polarities)
.250 type
(1 polarity)
© Panasonic Corporation 2014
.187 type
(3 polarities)
AECTB9E 201403-T