Please contact us
about TÜV certified
products.
AQ8
SIL type SSR with
9mm thickness
controls up to 3A
AQ8 RELAYS
FEATURES
RoHS compliant
1. Slim with 9 mm .354 inch thickness
The thin type (45 mm long × 24 mm high
× 9 mm wide) (1.772×.945×.354 inch)
permits high density mounting.
2. Excellent in noise resistance
Since the input and output are insulated
by the phototriac coupler, the noise on
the output side is not fed back to the input
side.
3. Snubber circuit integrated
The snubber circuit is integrated to
prevent malfunction caused by the rapid
rise of the voltage on the output side,
such as inductive load and noise.
4. Zero-cross and random types are
available.
The zero-cross type generates minimal
noise by suppressing occurrence of radio
frequency interference (RFI) and electromagnetic interference (EMI).
The random type features a short
operation time which permits phase
control.
5. High dielectric strength: 3,000 V AC
(between input and output)
6. Two kinds of terminals distance are
available. (5.08 mm and 7.62 mm) (.200
and .300 inch)
7. High reliability, long life and
maintenance-free
TYPICAL APPLICATIONS
1. Most suitable as drivers for small
size AC motors, solenoids, solenoid
valves and so on.
2. Copying equipment
3. Air conditioners
4. Industrial equipment such as NC
machines, sequencers, robots, etc.
ORDERING INFORMATION
AQ
Load current
2A
3A
Load voltage
1: 75 to 125 V AC
2: 75 to 250 V AC
Input terminal distance
C1: 5.08 mm .200 inch
C2: 7.62 mm .300 inch
Type
ZT: Zero-cross type
T: Random type
Input voltage
5, 12, 24 V DC
ASCTB213E 201201-T1
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
AQ8
TYPES
Types
Load current
Load voltage
Input voltage
5 V DC
12 V DC
24 V DC
5 V DC
12 V DC
24 V DC
5 V DC
12 V DC
24 V DC
5 V DC
12 V DC
24 V DC
5 V DC
12 V DC
24 V DC
5 V DC
12 V DC
24 V DC
5 V DC
12 V DC
24 V DC
5 V DC
12 V DC
24 V DC
75 to 125V AC
2A
75 to 250V AC
Zero-cross type
75 to 125V AC
3A
75 to 250V AC
75 to 125V AC
2A
75 to 250V AC
Random type
75 to 125V AC
3A
75 to 250V AC
Input terminals distance
(5.08 mm .200 inch type)
Part No.
AQ2A1-C1-ZT5V DC
AQ2A1-C1-ZT12V DC
AQ2A1-C1-ZT24V DC
AQ2A2-C1-ZT5V DC
AQ2A2-C1-ZT12V DC
AQ2A2-C1-ZT24V DC
AQ3A1-C1-ZT5V DC
AQ3A1-C1-ZT12V DC
AQ3A1-C1-ZT24V DC
AQ3A2-C1-ZT5V DC
AQ3A2-C1-ZT12V DC
AQ3A2-C1-ZT24V DC
AQ2A1-C1-T5V DC
AQ2A1-C1-T12V DC
AQ2A1-C1-T24V DC
AQ2A2-C1-T5V DC
AQ2A2-C1-T12V DC
AQ2A2-C1-T24V DC
AQ3A1-C1-T5V DC
AQ3A1-C1-T12V DC
AQ3A1-C1-T24V DC
AQ3A2-C1-T5V DC
AQ3A2-C1-T12V DC
AQ3A2-C1-T24V DC
Input terminals distance
(7.62 mm .300 inch type)
Part No.
AQ2A1-C2-ZT5V DC
AQ2A1-C2-ZT12V DC
AQ2A1-C2-ZT24V DC
AQ2A2-C2-ZT5V DC
AQ2A2-C2-ZT12V DC
AQ2A2-C2-ZT24V DC
AQ3A1-C2-ZT5V DC
AQ3A1-C2-ZT12V DC
AQ3A1-C2-ZT24V DC
AQ3A2-C2-ZT5V DC
AQ3A2-C2-ZT12V DC
AQ3A2-C2-ZT24V DC
AQ2A1-C2-T5V DC
AQ2A1-C2-T12V DC
AQ2A1-C2-T24V DC
AQ2A2-C2-T5V DC
AQ2A2-C2-T12V DC
AQ2A2-C2-T24V DC
AQ3A1-C2-T5V DC
AQ3A1-C2-T12V DC
AQ3A1-C2-T24V DC
AQ3A2-C2-T5V DC
AQ3A2-C2-T12V DC
AQ3A2-C2-T24V DC
Standard packing: Carton 20 pcs., Case 200 pcs.
RATING
1. Rating (Ambient temperature: 20°C, 68°F; Voltage ripple on the input side: 1% or less)
1) Zero-cross type
• 2 A type
Part No.
Item
Control voltage
Input
side
Input impedance
Drop-out voltage
AQ2A1-C1ZT5VDC
AQ2A1-C2ZT5VDC
AQ2A1-C1ZT12VDC
AQ2A1-C2ZT12VDC
5 V DC
12 V DC
(4 to 6V)
(9.6 to 14.4V)
Approx. 0.18 kΩ Approx. 0.55 kΩ
Min. 0.5 V
Min. 1.2 V
AQ2A1-C1ZT24VDC
AQ2A1-C2ZT24VDC
24 V DC
(21.6 to 26.4V)
Approx. 1.4 kΩ
Min. 2.4 V
Max. load current
Load
side
Load voltage
Frequency
Repetitive peak
OFF voltage
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
AQ2A2-C1ZT5VDC
AQ2A2-C2ZT5VDC
AQ2A2-C1ZT12VDC
AQ2A2-C2ZT12VDC
5 V DC
12 V DC
(4 to 6V)
(9.6 to 14.4V)
Approx. 0.18 kΩ Approx. 0.55 kΩ
Min. 0.5 V
Min. 1.2 V
AQ2A2-C1ZT24VDC
AQ2A2-C2ZT24VDC
24 V DC
(21.6 to 26.4V)
Approx. 1.4 kΩ
Min. 2.4 V
*1
At ambient temperature of
30°C or less
2 A*2
75 to 125 V AC
Remarks
75 to 250 V AC
45 to 65 Hz
400 V
600 V
In one cycle at 60 Hz
30 A*3
2.5 mA (100 V applied)
OFF state dV/dt
Panasonic Corporation
5 mA (200 V applied)
1.6 V
at 60 Hz
at max. carrying current
50 mA*4
25 mA*4
At ambient temperature of
80°C
50 V/µs
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB213E 201201-T1
AQ8
• 3 A type
Part No.
Item
Control voltage
Input
side
Input impedance
Drop-out voltage
AQ3A1-C1ZT5VDC
AQ3A1-C2ZT5VDC
AQ3A1-C1ZT12VDC
AQ3A1-C2ZT12VDC
5 V DC
12 V DC
(4 to 6V)
(9.6 to 14.4V)
Approx. 0.18 kΩ Approx. 0.55 kΩ
Min. 0.5 V
Min. 1.2 V
AQ3A1-C1ZT24VDC
AQ3A1-C2ZT24VDC
24 V DC
(21.6 to 26.4V)
Approx. 1.4 kΩ
Min. 2.4 V
Max. load current
Load
side
AQ3A2-C1ZT12VDC
AQ3A2-C2ZT12VDC
5 V DC
12 V DC
(4 to 6V)
(9.6 to 14.4V)
Approx. 0.18 kΩ Approx. 0.55 kΩ
Min. 0.5 V
Min. 1.2 V
AQ3A2-C1ZT24VDC
AQ3A2-C2ZT24VDC
24 V DC
(21.6 to 26.4V)
Approx. 1.4 kΩ
Min. 2.4 V
Remarks
*1
At ambient temperature of
30°C or less
3 A*2
Load voltage
Frequency
Repetitive peak
OFF voltage
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
75 to 125 V AC
75 to 250 V AC
45 to 65 Hz
400 V
600 V
In one cycle at 60 Hz
80 A*3
2.5 mA (100 V applied)
5 mA (200 V applied)
at 60 Hz
1.6 V
at max. carrying current
50 mA*
25 mA*
4
4
OFF state dV/dt
Notes: *1.
*2.
*3.
*4.
AQ3A2-C1ZT5VDC
AQ3A2-C2ZT5VDC
At ambient temperature of
80°C
50 V/µs
Refer to REFERENCE DATA “3. Characteristics of input current vs. input voltage”.
Refer to REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
Refer to REFERENCE DATA “2. Characteristics of non-repetitive surge current vs. carrying time”.
When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2) Random type
• 2 A type
Part No.
Item
Control voltage
Input
side
Input impedance
Drop-out voltage
AQ2A1-C1T5VDC
AQ2A1-C2T5VDC
AQ2A1-C1T12VDC
AQ2A1-C2T12VDC
AQ2A1-C1T24VDC
AQ2A1-C2T24VDC
AQ2A2-C1T5VDC
AQ2A2-C2T5VDC
AQ2A2-C1T12VDC
AQ2A2-C2T12VDC
AQ2A2-C1T24VDC
AQ2A2-C2T24VDC
5 V DC
(4 to 6V)
Approx. 0.3 kΩ
Min. 0.5 V
12 V DC
(9.6 to 14.4V)
Approx. 0.8 kΩ
Min. 1.2 V
24 V DC
(21.6 to 26.4V)
Approx. 1.8 kΩ
Min. 2.4 V
5 V DC
(4 to 6V)
Approx. 0.3 kΩ
Min. 0.5 V
12 V DC
(9.6 to 14.4V)
Approx. 0.8 kΩ
Min. 1.2 V
24 V DC
(21.6 to 26.4V)
Approx. 1.8 kΩ
Min. 2.4 V
Max. load current
Load
side
Load voltage
Frequency
Repetitive peak
OFF voltage
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
75 to 250 V AC
45 to 65 Hz
400 V
600 V
In one cycle at 60 Hz
30 A*3
2.5 mA (100 V applied)
5 mA (200 V applied)
1.6 V
at max. carrying current
4
50 V/µs
Panasonic Corporation
at 60 Hz
50 mA*
25 mA*
4
OFF state dV/dt
ASCTB213E 201201-T1
*1
At ambient temperature of
30°C or less
2 A*2
75 to 125 V AC
Remarks
Automation Controls Business Unit
At ambient temperature of
80°C
industrial.panasonic.com/ac/e/
AQ8
• 3 A type
Part No.
AQ3A1-C1T5VDC
AQ3A1-C2T5VDC
AQ3A1-C1T12VDC
AQ3A1-C2T12VDC
AQ3A1-C1T24VDC
AQ3A1-C2T24VDC
AQ3A2-C1T5VDC
AQ3A2-C2T5VDC
AQ3A2-C1T12VDC
AQ3A2-C2T12VDC
AQ3A2-C1T24VDC
AQ3A2-C2T24VDC
5 V DC
(4 to 6V)
Approx. 0.3 kΩ
Min. 0.5 V
12 V DC
(9.6 to 14.4V)
Approx. 0.8 kΩ
Min. 1.2 V
24 V DC
(21.6 to 26.4V)
Approx. 1.8 kΩ
Min. 2.4 V
5 V DC
(4 to 6V)
Approx. 0.3 kΩ
Min. 0.5 V
12 V DC
(9.6 to 14.4V)
Approx. 0.8 kΩ
Min. 1.2 V
24 V DC
(21.6 to 26.4V)
Approx. 1.8 kΩ
Min. 2.4 V
Item
Control voltage
Input
side
Input impedance
Drop-out voltage
Max. load current
Load
side
75 to 125 V AC
75 to 250 V AC
45 to 65 Hz
400 V
600 V
In one cycle at 60 Hz
80 A*3
2.5 mA (100 V applied)
5 mA (200 V applied)
at 60 Hz
1.6 V
at max. carrying current
50 mA*
25 mA*
4
4
OFF state dV/dt
Notes: *1.
*2.
*3.
*4.
*1
At ambient temperature of
30°C or less
3 A*2
Load voltage
Frequency
Repetitive peak
OFF voltage
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
Remarks
At ambient temperature of
80°C
50 V/µs
Refer to REFERENCE DATA “3. Characteristics of input current vs. input voltage”.
Refer to REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
Refer to REFERENCE DATA “2. characteristics of non-repetitive surge current vs. carrying time”.
When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics (Ambient temperature: 20°C 68°F; Input voltage ripple: 1% or less)
Type
Item
Operate time, max.
Release time, max.
Insulation resistance, min.
Breakdown voltage
Vibration
resistance
Destructive
Functional
Destructive
Functional
Ambient temperature
Storage temperature
Operational method
Shock
resistance
Zero-cross type
Random type
1/2 cycle of voltage sine wave + 1 ms
1/2 cycle of voltage sine wave + 1 ms
109Ω between input and output
3,000 V AC between input and output
Remarks
1 ms
at 500 V DC
For 1 minute
10 to 55 Hz at double amplitude of 3 mm
10 to 55 Hz at double amplitude of 3 mm
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
–30°C to +80°C –22°F to +176°F
–30°C to +100°C –22°F to +212°F
Zero-cross (Turn ON and Turn OFF)
Random turn ON, zero-cross turn OFF
1 hour for X, Y, Z axis
10 min. for X, Y, Z axis
5 times each for X, Y, Z axis
4 times each for X, Y, Z axis
1. Characteristics of load current vs. ambient
temperature
2.-(1) Characteristics of non-repetitive surge
current vs. carrying time
2.-(2) Characteristics of non-repetitive surge
current vs. carrying time
Use load current within range specified in the figure
below.
(2 A type)
(3 A type)
Non-repetitive surge current, A
Non-repetitive surge current, A
REFERENCE DATA
3.0
Load current, A
3 A type
2.5
2 A type
2.0
1.5
1.0
80
60
40
20
0.5
0
–30
100
0
20
40
60
80
Ambient temperature, °C
Panasonic Corporation
0
100
80
60
40
20
5
10
50
No. of cycles at 60 Hz
Automation Controls Business Unit
100
0
industrial.panasonic.com/ac/e/
5
10
50
No. of cycles at 60 Hz
100
ASCTB213E 201201-T1
AQ8
3. Characteristics of input current vs. input
voltage
4.-(1) Characteristics of load current vs.
ambient temperature for adjacent mounting
4.-(2) Characteristics of load current vs.
ambient temperature for adjacent mounting
—zero-cross type
---Random type
(2 A type)
Conditions: Natural cooling
(3 A type)
Conditions: Natural cooling
30
2.5
Load current, A
Input current, mA
20
15
10
=20.32 mm
.800 inch
=12.7 mm
.500 inch
=9.0 mm
.354 inch
2.0
(12 V type)
(24 V type)
1.5
1.0
Load current, A
3.0
25
=20.32 mm
.800 inch
=12.7 mm
.500 inch
=9.0 mm
.354 inch
2.0
1.0
(5 V type)
0.5
5
=Adjacent mounting pitch
0
0
10
0
–30
20
30
Input voltage, V
DIMENSIONS (mm inch)
0
The CAD data of the products with a
(Common for zero-cross and random types)
1. Input terminals distance 5.08 mm .200 inch
1) 2 A type
=Adjacent mounting pitch
0
–30
20
40
60
80
Ambient temperature, °C
CAD Data
Mounting hole location (Bottom view)
9 max.
.354
45 max.
1.772
20
40
60
80
Ambient temperature, °C
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
0
27.94
1.100
Terminal 4
3
Copper foil
2
1
4-1.2 dia.
4-.047 dia.
2.54× 2
.100× 2
24 max.
.945
– 4INPUT3 +
5.08
.200
4
5.08
.200
10.16
.400
12.7
.500
3
2
2.54× 4
.100× 4
Tolerance: ±0.1 ±.004
2 LOAD 1
8 min.
.315
2.5
.098
2.54× 5
.100× 5
Schematic
4-0.8 dia.
4-.031
INPUT
4 3
LOAD
2 1
1
General tolerance: ±0.5 ±.020
– +
Load
Input
Load
power source power source
2) 3 A type
External dimensions
CAD Data
Mounting hole location (Bottom view)
9 max.
.354
43 max.
1.693
27.94
1.100
Terminal 4
3
Copper foil
2
1
4-1.2 dia.
4-.047 dia.
2.54× 5
.100× 5
2.54× 2
.100× 2
32 max.
1.259
– 4INPUT3 +
2.54× 4
.100× 4
Tolerance: ±0.1 ±.004
Schematic
2 LOAD 1
8 min.
.315
2.5
.098
5.08
.200
4
12.7
.500
3
5.08
.200
10.16
.400
2
4-0.8 dia.
4-.031
1
General tolerance: ±0.5 ±.020
ASCTB213E 201201-T1
Panasonic Corporation
Automation Controls Business Unit
INPUT
4 3
LOAD
2 1
– +
Load
Input
Load
power source power source
industrial.panasonic.com/ac/e/
AQ8
2. Input terminals distance 7.62 mm .300 inch
1) 2A type
External dimensions
Mounting hole location (Bottom view)
CAD Data
9 max.
.354
45 max.
1.772
30.48
1.200
Terminal 4
3
Copper foil
2
1
4-1.2 dia.
4-.047 dia.
24 max.
.945
– 4INPUT 3+
2.54× 3
.100× 3
7.62
.300
4
5.08
.200
10.16
.400
12.7
.500
3
2
2.54× 4
.100× 4
Tolerance: ±0.1 ±.004
2 LOAD 1
8 min.
.315
2.5
.098
2.54× 5
.100× 5
Schematic
4-0.8 dia.
4-.031
INPUT
4 3
LOAD
2 1
1
General tolerance: ±0.5 ±.020
– +
Load
Input
Load
power source power source
2) 3A type
External dimensions
CAD Data
Mounting hole location (Bottom view)
9 max.
.354
43 max.
1.693
30.48
1.200
Terminal 4
3
Copper foil
2
1
4-1.2 dia.
4-.047 dia.
2.54× 5
.100× 5
2.54× 3
.100× 3
32 max.
1.259
– 4 INPUT3+
2.54× 4
.100× 4
Tolerance: ±0.1 ±.004
Schematic
2 LOAD 1
8 min.
.315
2.5
.098
7.62
.300
4
3
12.7
.500
5.08
.200
10.16
.400
2
4-0.8 dia.
4-.031
1
General tolerance: ±0.5 ±.020
Panasonic Corporation
Automation Controls Business Unit
INPUT
4 3
LOAD
2 1
– +
Load
Input
Load
power source power source
industrial.panasonic.com/ac/e/
ASCTB213E 201201-T1
AQ8
NOTE
1. When used for the load less than
rated
In case of the load current less than
rated, malfunction may result from the
residual voltage across the both ends of
the load even if the solid state relay is
turned off. Use a dummy resistor as a
countermeasure.
The total of the current through the
resistor and the load current must exceed
the min. rated load current.
R0 Dummy resistor
SSR
1
• Characteristics of residual voltage vs.
load impedance
100
80
f = 60Hz
Ve: Residual voltage
V: Power voltage
1
60
Ve
× 100
V
(%)
40
Load
SSR
2
V
Ve
Power factor: 1
(resistor load)
Power factor: 0.4
(induction load)
20
Load
0
Load
power
source
2
In case the dummy resistor is not used,
keep in mind that the residual voltage
becomes as follows:
Example:
For the inductive load by the 20 mA load
current and the 200 V AC load voltage,
the load impedance becomes 10 k Ω and
Ve/V = 14% is estimated from the right
above graph. Accordingly, the 28 V
voltage remains across the both ends of
the load when the solid state relay is
turned off.
10
30
20
40
50
Load impedance (kΩ)
2. when the terminal is bent
Care shall be taken neither to apply
mechanical stresses to the mold area of
the solid state relay nor to bend the
terminal 45 degrees or more.
Max.
45°
Solid
state relay
Printed circuit board
Solder
Recommended Temperature Controllers
Our temperature controller is recommended for use with our Solid State Relays.
48mm
1.890inch
56mm
2.205inch
Features
• Space saving requiring only a depth of 65 mm
• Data collection possible through a PLC using RS485 communication
• Tool port is standard for easy data setting
• Inverted LCD + backlight for good legibility with large characters
• Excellent operability and rich optional control functions
Substitute part numbers
48mm
1.890inch
Power supply
100 to 240 V AC
Control output
Non-contact voltage output
Part No.
AKT4H112100
* For detailed product information about temperature controllers, please refer to our website:
http://industrial.panasonic.com/ac/e/
For Cautions for Use.
ASCTB213E 201201-T1
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
很抱歉,暂时无法提供与“AQ2A2-C1-ZT24VDC”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 20+113.0010620+14.66180