Please contact us about
TÜV certified products.
Certified
AQ1AD2-3/28VDC
and AQ2AD1-3/28VDC
Certified
AQ1AD2-3/28VDC
and AQ2AD1-3/28VDC
Certified
AQ10A2-ZT4/32VDC,
AQ3A2-ZT4/32VDC,
and AQ3A2-J-ZT4/32VDC
High capacity up to 10A
PCB terminal type
Certified
AQ1AD2-3/28VDC and
AQ2AD1-3/28VDC
VDE
Certified
AQ3A2-ZT4/32VDC,
AQ3A2-J-ZT4/32VDC and
AQ10A2-ZT4/32VDC
AQ1
AQ1 RELAYS
AQ1
FEATURES
mm inch
10
.394
33
1.299
26
1.024
25
.984
33
1.299
12
.472
1. 10A high-capacity realized for PC
board terminal (with heat sink)
SSR for compact PC boards with 10 A
capacity that is two times greater than
our previous model. It is suitable for longlife, highly frequent control.
2. VDE (EN60950-1) reinforced
insulation compliant
Fully satisfies demand for safety by
guaranteeing compliance with
EN60950-1 safety standard and featuring
3,000 V reinforced insulation (AQ3A2ZT4/32VDC, AQ3A2-J-ZT4/32VDC and
AQ10A2-ZT4/32VDC).
3. Superior anti-vibration and antishock characteristics
The body is molded as a single unit with
flame resistant resin which makes it
highly resistant against vibration and
shock, and gives it superior protection
from environment. The body can also be
washed.
4. Vertical types with SIL terminal
arrangement and flat types are
available.
1) The vertical type is available in
thicknesses of 10 mm (2 A and 3 A types)
and 12 mm (10 A types). Terminal
arrangement is SIL in integral multiples of
2.54 mm (0.1 inch).
2) The height of the flat type is 12 mm.
The terminal arrangement is DIL in
integral multiples of 2.54 mm.
5. Reduced noise generation
The load will operate at close to zero
voltage even when the input signal is
applied during a cycle. Also, even if an
input signal is cancelled during a cycle,
the load is cut off at close to zero current.
For this reason, hardly any noise is
produced and radio frequency
interference (RFI) and electromagnetic
interference (EMI) are kept to a minimum.
6. Built-in Snubber circuit prevents
malfunction.
TYPICAL APPLICATIONS
• Printing machines
• Packing machines
• Traffic signal control
• Automatic ticket punchers
• Terminal equipment of data processing
• Computer peripherals
• NC machines
ORDERING INFORMATION
AQ
Load current
1 A, 2 A, 3 A, 10 A
Load voltage
2: 75 to 250 V AC
D1: 3 to 60 V DC
D2: 10 to 200 V DC
Shape
Nil: Vertical type
J: Flat type
Nil: DC output
ZT: Zero-cross AC output (Phototriac coupler)
Input voltage
3/28 V DC: 3 to 28 V DC
4/32 V DC: 4 to 32 V DC
* Random types are available upon request.
ds_61601_en_aq1: 011212D
1
AQ1
TYPES
1. AQ1 Solid State Relays
Load
Isolation
Zero-cross
function
AC
Phototriac coupler
Zero-cross*1
DC
Optically
coupled isolation
Type
3 A (Vertical)
3 A (flat)
10 A
1A
2A
–
Input
voltage
4 to 32 V DC
4 to 32 V DC
4 to 32 V DC
3 to 28 V DC
3 to 28 V DC
Load current
Load voltage
3 A, 75 to 250 V AC
3 A, 75 to 250 V AC
10 A, 75 to 250 V AC
1 A, 10 to 200 V DC
2 A, 3 to 60 V DC
Part No.
AQ3A2-ZT4/32VDC
AQ3A2-J-ZT4/32VDC
AQ10A2-ZT4/32VDC
AQ1AD2-3/28VDC
AQ2AD1-3/28VDC
Standard packing: Carton 20 pcs., Case 200 pcs.
Note: *1 Non zero-cross type also available. Please inquire.
2. Heat sink for AQ1 solid state relay
Product name
Heat sink for AQ10A2-ZT4/32VDC
Part No.
AQ-HS-5A
Standard packing: Carton 20 pcs., Case 200 pcs.
SPECIFICATIONS
1. Rating (Ambient temperature: 20C 68F, Ripple factor: less than 1%)
Type
Item
Input
side
Input voltage
Input impedance
Input current, max.
Drop-out voltage, min.
Max. load current*2
Load voltage
Load
side
AC output type
Zero-cross
3 A type
10 A type
DC output type
1 A type
4 to 32 V DC
—
20 mA
1.0 V
3A
3 to 28 V DC
Approx. 1.6 k
—
0.8 V
10 A*5
75 to 250 V AC
*1
1A
2A
10 to 200 V DC
3 to 60 V DC
Non-repetitive surge
current*3
100 A
5A
Max. “OFF-state” leakage
current
5 mA
1 mA
Max. “ON-state” voltage
drop
Min. load current*4
Remarks
2 A type
1.6 V
1.6 V
50 mA
2.3 V
Refer to REFERENCE DATA
“1. Load current vs. ambient
temperature characteristics”.
AC: In one cycle at 60 Hz,
DC: 1s
AC: at 200 V, 60Hz
DC: When maximum load
voltage is applied.
At Max. carrying current
5 mA
Notes:
*1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When load current is below the rating, refer to “Cautions for Use” on page 341.
*5. When heat sink (AQ-HS-5A) is installed. The max. load current is 5 A when heat sink is not installed.
2. Characteristics (at 20C 68F, Ripple factor: less than 1%)
Type
Item
Operate time, Max.
Release time, Max.
Insulation resistance, Min.
Breakdown voltage
Destructive
Vibration resistance
Functional
Destructive
Functional
Ambient temperature
Storage temperature
Operational method
Shock resistance
2
AC output
Zero-cross
3 A type
10 A type
(1/2 cycle of voltage sine wave) + 1 ms
(1/2 cycle of voltage sine wave) + 1 ms
100 M for input, output and case
4,000 Vrms between input and output
2,500 Vrms among input, output and case
DC output
0.5 ms
2 ms
100 M for input, output
3,000 Vrms
between input-output
117.6 m/s2 {12G},
117.6 m/s2 {12G}, 10 to 55 Hz at double
10 to 55 Hz at double
amplitude of 2 mm
amplitude of 2 mm
117.6 m/s2 {12G},
117.6 m/s2 {12G}, 10 to 55 Hz at double
10 to 55 Hz at double
amplitude of 2 mm
amplitude of 2 mm
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
–30C to +80C –22F to +176F
–30C to +100C –22F to +212F
Zero-cross (Turn-ON and Turn-OFF)
—
Remarks
at 500 V DC
For 1 minute
1 hour for
X, Y, Z axis
10 minutes for
X, Y, Z axis
5 times each for X, Y, Z axis
4 times each for X, Y, Z axis
ds_61601_en_aq1: 011212D
AQ1
REFERENCE DATA
1-(1) Load current vs. ambient temperature
1.-(2) Load current vs. ambient temperature
1.-(3) Load current vs. ambient temperature
(AC output, 3 A type) Part No.: AQ3A2-ZT4/32VDC
and AQ3A2-J-ZT4/32VDC
Allowable ambient temperature:
–30C to +80C –22F to +176F
(AC output, 10 A type) Part No.: AQ10A2-ZT4/32VDC
(A) When not using a heat sink
(B) When using a standard heat sink AQ-HS-5A
(When attached to a heat sink, use a heat conductive
compound (Ex. Toshiba silicone YG6111 or TSK5303)
of similar coating to improve cooling.)
(DC output, 1 A and 2 A types) Part No.: AQ1AD2-3/
28VDC and AQ2AD1-3/28VDC
Allowable ambient temperature:
–30C to +80C –22F to +176F
5
10
4
8
2.5
3
2
1
6
(A)
4
2
0
-30
0
20
40
60
80
0
-30
100
Ambient temperature, °C
2A type
2.0
Load current, A
Load current, A
Load current, A
(B)
1.5
1A type
1.0
0.5
0
20
40
60
80
0
100
-30
0
20
Ambient temperature, °C
40
60
80
Ambient temperature, °C
2-(1) Non-repetitive surge current vs.
carrying time
2.-(2) Non-repetitive surge current vs.
carrying time
3-(1) Input current vs. input voltage
characteristics
(AC output, 3 A and 10 A types)
Part No.: AQ3A2-ZT4/32VDC, AQ3A2-J-ZT4/32VDC
and AQ10A2-ZT4/32VDC
(DC output) Part No.: AQ1AD2-3/28VDC and
AQ2AD1-3/28VDC
(AC output, 3 A and 10 A types)
Part No.: AQ3A2-ZT4/32VDC, AQ3A2-J-ZT4/32VDC
and AQ10A2-ZT4/32VDC
100
75
50
25
25
22
20
Input current, mA
Non-repetitive surge current, A
Non-repetitive surge current, A
125
18
16
14
12
10
8
20
15
10
6
5
4
2
0
0
1
10
100
1
50
100
0
500 1,000
0
5
10
Carrying time, ms
No. of cycles at 60 Hz
15
20
25
30
35
Input voltage, V
4.-(1) Load current vs. ambient temperature
characteristics for adjacent mounting
4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting
(DC output)
Part No.: AQ1AD2-3/28VDC and AQ2AD1-3/28VDC
(AC output, 3A vertical type)
Part No.: AQ3A2-ZT4/32VDC
(AC output, 10A type)
Part No.: AQ10A2-ZT4/32VDC (without heat sink)
5
28
26
24
22
20
18
16
14
12
10
8
6
4
2
6
5
3
Load current, A
4
Load current, A
Input current, mA
3.-(2) Input current vs. input voltage
characteristics
=15.24mm
.600inch
=20.32mm
.800inch
4
3
2
2
= Adjacent mounting pitch
1
0
4
8
12
16
20
24
Input voltage, V
ds_61601_en_aq1: 011212D
28 30
= Adjacent mounting pitch
0
0
20
-30 -20
40
60
80
Ambient temperature, °C
1
100
0
-30 -20
0
20
40
60
80
Ambient temperature, °C
100
3
AQ1
DIMENSIONS (mm inch)
CAD Data
Data from our Web site.
Download CAD
1. AC output, 3A types (Vertical)
Mounting hole location
(Copper-side view)
CAD Data
33
1.299
25.4
1.000
10
.394
1
Copper foil
2
3
4
4-1.2 dia.
4-.047 dia.
2.54×3
.100×3
OUTPUT
1
INPUT
Schematic
1
.039
6
.236
7.62 12.7
.300 .500
2.54×2
.100×2
25
.984
3 4
2
2.54×5
.100×5
SSR
5.08
.200
LOAD
1 2
INPUT
3 4
(25.4)
(1.000)
+ Load
Input
Load
power source power source
5.3
.209
4-0.8 dia.
4-.031 dia.
General tolerance: 0.5 .020
Tolerance: 0.1 .004
2. AC output, 3A types (Flat)
Mounting hole location
(Copper-side view)
CAD Data
33
1.299
4-1.2 dia.
4-.047 dia.
25.4
1.000
Copper foil
2
3
25
.984
10.16
.400
12.7
.500
4
11
.433
6
.236
4-0.8 dia.
4-.031 dia.
1
Schematic
1
.039
+
2
INPUT OUTPUT
4
-
Load
3
10.16
.400
Input
power source
+ -
Load
power source
25.4
1.000
12.7
.500
1
2
3
SSR LOAD
INPUT
1
4
General tolerance: 0.5 .020
Tolerance: 0.1 .004
3. AC output, 10A types
Mounting hole location (Copper-side view)
CAD Data
4
.157
25
.984
1
3
2.54×3
.100×3
4
2.54×5
.100×5
9.1
.358
2.54×2
.100×2
2-3.5 dia.*
2-.138 dia.
LOAD INPUT
1
.039
15 max.
.591
0.8
.031
7.62
.300
12.7
.500
20
.787
20
.787
* There 2 holes are not necessary when not using heat sink (AQ-HS-5A)
Schematic
7.62
.300
5.08
.200
0.6
.024
12 max.
.472
SSR
LOAD
1 2
INPUT
3 4
6.9
.272
2
.079
2
.079
8.8910.16
.350 .400
General tolerance: 0.5 .020
4
2
Copper foil
1 2 + 34 -
2
.079
4-1.2 dia.
4-.047 dia.
25.4
1.000
54
2.126
39
1.535
33
1.299
+ Load
Input
Load
power source power source
Tolerance: 0.1 .004
ds_61601_en_aq1: 011212D
AQ1
4. Heat sink (for AQ10A2-ZT4/32VDC)
mm inch
CAD Data
58±2
2.283±.079
2-M3 Screw
13.8
.543
27±2
1.063±.079
5.2
.205
47.6
1.874
40
1.575
2.5
.098
9
.354
30±2
1.181±.079
2-M3 Screw depth: min. 10mm
8 8 8 8 8 8 8
.315.315.315.315.315.315.315
Knurl surface
Heat sink attached to AQ1 relay
General tolerance: 0.5 .020
Note: When using heat sink, please refer to “Thermal Design”
5. DC output, 1A and 2A types
Mounting hole location
(Copper-side view)
CAD Data
33
1.299
10
.394
25.4
1.000
1
2
Copper foil
3
4
4-1.2 dia.
4-.047 dia.
2.54×3
.100×3
OUTPUT
1
25
.984
INPUT
3 4
2
Schematic
SSR
5.08
.200
(25.4)
(1.000)
4-0.8 dia.
4-.031 dia.
2.54×2
.100×2
1
.039
6
.236
7.62 12.7
.300 .500
2.54×5
.100×5
5.3
.209
General tolerance: 0.5 .020
LOAD
1 2
INPUT
3 4
+ + Load
Input
Load
power source power source
Tolerance: 0.1 .004
CAUTIONS FOR USE
1. When using bent output terminals
To avoid applying mechanical stress on
the main unit and molded section of the
solid state relay, radio pliers should be
used to grasp the terminals between the
point of bending and the molded case
when making the bends.
Solid state relay
Terminal bend section
Printed circuit board
Solder
2. When a heat sink is mounted on the
10 A type
The heat sink (AQ-HS-5A) or a radiator
which can make good contact should be
used.
If a heat sink is used in which the contact
condition is bad, a heat conducting
compound should be used to improve the
heat radiation. (Ex. Silicon compound
Toshiba silicon YG6111 or TSK5303) The
compound should be applied between
the heat sink and the AQ1.
AQ-HS-5A heat sink
10 A type AQ1 SSR
Printed circuit board
4-M3 screws
(provided with AQ-HS-5A)
Approx. 0.6N·m of torque should be
used for tightening the M3 screws.
Cautions for Use
ds_61601_en_aq1: 011212D
5