AQ2AD1-3/28VDC

AQ2AD1-3/28VDC

  • 厂商:

    NAIS(松下)

  • 封装:

    SIP-4

  • 描述:

    SSR 2A 60VDC 3/28VDC DC OUTPUT

  • 数据手册
  • 价格&库存
AQ2AD1-3/28VDC 数据手册
Please contact us about TÜV certified products. Certified AQ1AD2-3/28VDC and AQ2AD1-3/28VDC Certified AQ1AD2-3/28VDC and AQ2AD1-3/28VDC Certified AQ10A2-ZT4/32VDC, AQ3A2-ZT4/32VDC, and AQ3A2-J-ZT4/32VDC High capacity up to 10A PCB terminal type Certified AQ1AD2-3/28VDC and AQ2AD1-3/28VDC VDE Certified AQ3A2-ZT4/32VDC, AQ3A2-J-ZT4/32VDC and AQ10A2-ZT4/32VDC AQ1 AQ1 RELAYS AQ1 FEATURES mm inch 10 .394 33 1.299 26 1.024 25 .984 33 1.299 12 .472 1. 10A high-capacity realized for PC board terminal (with heat sink) SSR for compact PC boards with 10 A capacity that is two times greater than our previous model. It is suitable for longlife, highly frequent control. 2. VDE (EN60950-1) reinforced insulation compliant Fully satisfies demand for safety by guaranteeing compliance with EN60950-1 safety standard and featuring 3,000 V reinforced insulation (AQ3A2ZT4/32VDC, AQ3A2-J-ZT4/32VDC and AQ10A2-ZT4/32VDC). 3. Superior anti-vibration and antishock characteristics The body is molded as a single unit with flame resistant resin which makes it highly resistant against vibration and shock, and gives it superior protection from environment. The body can also be washed. 4. Vertical types with SIL terminal arrangement and flat types are available. 1) The vertical type is available in thicknesses of 10 mm (2 A and 3 A types) and 12 mm (10 A types). Terminal arrangement is SIL in integral multiples of 2.54 mm (0.1 inch). 2) The height of the flat type is 12 mm. The terminal arrangement is DIL in integral multiples of 2.54 mm. 5. Reduced noise generation The load will operate at close to zero voltage even when the input signal is applied during a cycle. Also, even if an input signal is cancelled during a cycle, the load is cut off at close to zero current. For this reason, hardly any noise is produced and radio frequency interference (RFI) and electromagnetic interference (EMI) are kept to a minimum. 6. Built-in Snubber circuit prevents malfunction. TYPICAL APPLICATIONS • Printing machines • Packing machines • Traffic signal control • Automatic ticket punchers • Terminal equipment of data processing • Computer peripherals • NC machines ORDERING INFORMATION AQ Load current 1 A, 2 A, 3 A, 10 A Load voltage 2: 75 to 250 V AC D1: 3 to 60 V DC D2: 10 to 200 V DC Shape Nil: Vertical type J: Flat type Nil: DC output ZT: Zero-cross AC output (Phototriac coupler) Input voltage 3/28 V DC: 3 to 28 V DC 4/32 V DC: 4 to 32 V DC * Random types are available upon request. ds_61601_en_aq1: 011212D 1 AQ1 TYPES 1. AQ1 Solid State Relays Load Isolation Zero-cross function AC Phototriac coupler Zero-cross*1 DC Optically coupled isolation Type 3 A (Vertical) 3 A (flat) 10 A 1A 2A – Input voltage 4 to 32 V DC 4 to 32 V DC 4 to 32 V DC 3 to 28 V DC 3 to 28 V DC Load current Load voltage 3 A, 75 to 250 V AC 3 A, 75 to 250 V AC 10 A, 75 to 250 V AC 1 A, 10 to 200 V DC 2 A, 3 to 60 V DC Part No. AQ3A2-ZT4/32VDC AQ3A2-J-ZT4/32VDC AQ10A2-ZT4/32VDC AQ1AD2-3/28VDC AQ2AD1-3/28VDC Standard packing: Carton 20 pcs., Case 200 pcs. Note: *1 Non zero-cross type also available. Please inquire. 2. Heat sink for AQ1 solid state relay Product name Heat sink for AQ10A2-ZT4/32VDC Part No. AQ-HS-5A Standard packing: Carton 20 pcs., Case 200 pcs. SPECIFICATIONS 1. Rating (Ambient temperature: 20C 68F, Ripple factor: less than 1%) Type Item Input side Input voltage Input impedance Input current, max. Drop-out voltage, min. Max. load current*2 Load voltage Load side AC output type Zero-cross 3 A type 10 A type DC output type 1 A type 4 to 32 V DC — 20 mA 1.0 V 3A 3 to 28 V DC Approx. 1.6 k — 0.8 V 10 A*5 75 to 250 V AC *1 1A 2A 10 to 200 V DC 3 to 60 V DC Non-repetitive surge current*3 100 A 5A Max. “OFF-state” leakage current 5 mA 1 mA Max. “ON-state” voltage drop Min. load current*4 Remarks 2 A type 1.6 V 1.6 V 50 mA 2.3 V Refer to REFERENCE DATA “1. Load current vs. ambient temperature characteristics”. AC: In one cycle at 60 Hz, DC: 1s AC: at 200 V, 60Hz DC: When maximum load voltage is applied. At Max. carrying current 5 mA Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”. *2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”. *3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”. *4. When load current is below the rating, refer to “Cautions for Use” on page 341. *5. When heat sink (AQ-HS-5A) is installed. The max. load current is 5 A when heat sink is not installed. 2. Characteristics (at 20C 68F, Ripple factor: less than 1%) Type Item Operate time, Max. Release time, Max. Insulation resistance, Min. Breakdown voltage Destructive Vibration resistance Functional Destructive Functional Ambient temperature Storage temperature Operational method Shock resistance 2 AC output Zero-cross 3 A type 10 A type (1/2 cycle of voltage sine wave) + 1 ms (1/2 cycle of voltage sine wave) + 1 ms 100 M  for input, output and case 4,000 Vrms between input and output 2,500 Vrms among input, output and case DC output 0.5 ms 2 ms 100 M  for input, output 3,000 Vrms between input-output 117.6 m/s2 {12G}, 117.6 m/s2 {12G}, 10 to 55 Hz at double 10 to 55 Hz at double amplitude of 2 mm amplitude of 2 mm 117.6 m/s2 {12G}, 117.6 m/s2 {12G}, 10 to 55 Hz at double 10 to 55 Hz at double amplitude of 2 mm amplitude of 2 mm Min. 980 m/s2 {100 G} Min. 980 m/s2 {100 G} Min. 980 m/s2 {100 G} Min. 980 m/s2 {100 G} –30C to +80C –22F to +176F –30C to +100C –22F to +212F Zero-cross (Turn-ON and Turn-OFF) — Remarks at 500 V DC For 1 minute 1 hour for X, Y, Z axis 10 minutes for X, Y, Z axis 5 times each for X, Y, Z axis 4 times each for X, Y, Z axis ds_61601_en_aq1: 011212D AQ1 REFERENCE DATA 1-(1) Load current vs. ambient temperature 1.-(2) Load current vs. ambient temperature 1.-(3) Load current vs. ambient temperature (AC output, 3 A type) Part No.: AQ3A2-ZT4/32VDC and AQ3A2-J-ZT4/32VDC Allowable ambient temperature: –30C to +80C –22F to +176F (AC output, 10 A type) Part No.: AQ10A2-ZT4/32VDC (A) When not using a heat sink (B) When using a standard heat sink AQ-HS-5A (When attached to a heat sink, use a heat conductive compound (Ex. Toshiba silicone YG6111 or TSK5303) of similar coating to improve cooling.) (DC output, 1 A and 2 A types) Part No.: AQ1AD2-3/ 28VDC and AQ2AD1-3/28VDC Allowable ambient temperature: –30C to +80C –22F to +176F 5 10 4 8 2.5 3 2 1 6 (A) 4 2 0 -30 0 20 40 60 80 0 -30 100 Ambient temperature, °C 2A type 2.0 Load current, A Load current, A Load current, A (B) 1.5 1A type 1.0 0.5 0 20 40 60 80 0 100 -30 0 20 Ambient temperature, °C 40 60 80 Ambient temperature, °C 2-(1) Non-repetitive surge current vs. carrying time 2.-(2) Non-repetitive surge current vs. carrying time 3-(1) Input current vs. input voltage characteristics (AC output, 3 A and 10 A types) Part No.: AQ3A2-ZT4/32VDC, AQ3A2-J-ZT4/32VDC and AQ10A2-ZT4/32VDC (DC output) Part No.: AQ1AD2-3/28VDC and AQ2AD1-3/28VDC (AC output, 3 A and 10 A types) Part No.: AQ3A2-ZT4/32VDC, AQ3A2-J-ZT4/32VDC and AQ10A2-ZT4/32VDC 100 75 50 25 25 22 20 Input current, mA Non-repetitive surge current, A Non-repetitive surge current, A 125 18 16 14 12 10 8 20 15 10 6 5 4 2 0 0 1 10 100 1 50 100 0 500 1,000 0 5 10 Carrying time, ms No. of cycles at 60 Hz 15 20 25 30 35 Input voltage, V 4.-(1) Load current vs. ambient temperature characteristics for adjacent mounting 4.-(2) Load current vs. ambient temperature characteristics for adjacent mounting (DC output) Part No.: AQ1AD2-3/28VDC and AQ2AD1-3/28VDC (AC output, 3A vertical type) Part No.: AQ3A2-ZT4/32VDC (AC output, 10A type) Part No.: AQ10A2-ZT4/32VDC (without heat sink) 5 28 26 24 22 20 18 16 14 12 10 8 6 4 2 6 5 3 Load current, A 4 Load current, A Input current, mA 3.-(2) Input current vs. input voltage characteristics =15.24mm .600inch =20.32mm .800inch 4 3 2 2 = Adjacent mounting pitch 1 0 4 8 12 16 20 24 Input voltage, V ds_61601_en_aq1: 011212D 28 30 = Adjacent mounting pitch 0 0 20 -30 -20 40 60 80 Ambient temperature, °C 1 100 0 -30 -20 0 20 40 60 80 Ambient temperature, °C 100 3 AQ1 DIMENSIONS (mm inch) CAD Data Data from our Web site. Download CAD 1. AC output, 3A types (Vertical) Mounting hole location (Copper-side view) CAD Data 33 1.299 25.4 1.000 10 .394 1 Copper foil 2 3 4 4-1.2 dia. 4-.047 dia. 2.54×3 .100×3 OUTPUT 1 INPUT Schematic 1 .039 6 .236 7.62 12.7 .300 .500 2.54×2 .100×2 25 .984 3 4 2 2.54×5 .100×5 SSR 5.08 .200 LOAD 1 2 INPUT 3 4 (25.4) (1.000) + Load Input Load power source power source 5.3 .209 4-0.8 dia. 4-.031 dia. General tolerance: 0.5 .020 Tolerance: 0.1 .004 2. AC output, 3A types (Flat) Mounting hole location (Copper-side view) CAD Data 33 1.299 4-1.2 dia. 4-.047 dia. 25.4 1.000 Copper foil 2 3 25 .984 10.16 .400 12.7 .500 4 11 .433 6 .236 4-0.8 dia. 4-.031 dia. 1 Schematic 1 .039 + 2 INPUT OUTPUT 4 - Load 3 10.16 .400 Input power source + - Load power source 25.4 1.000 12.7 .500 1 2 3 SSR LOAD INPUT 1 4 General tolerance: 0.5 .020 Tolerance: 0.1 .004 3. AC output, 10A types Mounting hole location (Copper-side view) CAD Data 4 .157 25 .984 1 3 2.54×3 .100×3 4 2.54×5 .100×5 9.1 .358 2.54×2 .100×2 2-3.5 dia.* 2-.138 dia. LOAD INPUT 1 .039 15 max. .591 0.8 .031 7.62 .300 12.7 .500 20 .787 20 .787 * There 2 holes are not necessary when not using heat sink (AQ-HS-5A) Schematic 7.62 .300 5.08 .200 0.6 .024 12 max. .472 SSR LOAD 1 2 INPUT 3 4 6.9 .272 2 .079 2 .079 8.8910.16 .350 .400 General tolerance: 0.5 .020 4 2 Copper foil 1 2 + 34 - 2 .079 4-1.2 dia. 4-.047 dia. 25.4 1.000 54 2.126 39 1.535 33 1.299 + Load Input Load power source power source Tolerance: 0.1 .004 ds_61601_en_aq1: 011212D AQ1 4. Heat sink (for AQ10A2-ZT4/32VDC) mm inch CAD Data 58±2 2.283±.079 2-M3 Screw 13.8 .543 27±2 1.063±.079 5.2 .205 47.6 1.874 40 1.575 2.5 .098 9 .354 30±2 1.181±.079 2-M3 Screw depth: min. 10mm 8 8 8 8 8 8 8 .315.315.315.315.315.315.315 Knurl surface Heat sink attached to AQ1 relay General tolerance: 0.5 .020 Note: When using heat sink, please refer to “Thermal Design” 5. DC output, 1A and 2A types Mounting hole location (Copper-side view) CAD Data 33 1.299 10 .394 25.4 1.000 1 2 Copper foil 3 4 4-1.2 dia. 4-.047 dia. 2.54×3 .100×3 OUTPUT 1 25 .984 INPUT 3 4 2 Schematic SSR 5.08 .200 (25.4) (1.000) 4-0.8 dia. 4-.031 dia. 2.54×2 .100×2 1 .039 6 .236 7.62 12.7 .300 .500 2.54×5 .100×5 5.3 .209 General tolerance: 0.5 .020 LOAD 1 2 INPUT 3 4 + + Load Input Load power source power source Tolerance: 0.1 .004 CAUTIONS FOR USE 1. When using bent output terminals To avoid applying mechanical stress on the main unit and molded section of the solid state relay, radio pliers should be used to grasp the terminals between the point of bending and the molded case when making the bends. Solid state relay Terminal bend section Printed circuit board Solder 2. When a heat sink is mounted on the 10 A type The heat sink (AQ-HS-5A) or a radiator which can make good contact should be used. If a heat sink is used in which the contact condition is bad, a heat conducting compound should be used to improve the heat radiation. (Ex. Silicon compound Toshiba silicon YG6111 or TSK5303) The compound should be applied between the heat sink and the AQ1. AQ-HS-5A heat sink 10 A type AQ1 SSR Printed circuit board 4-M3 screws (provided with AQ-HS-5A) Approx. 0.6N·m of torque should be used for tightening the M3 screws. Cautions for Use ds_61601_en_aq1: 011212D 5
AQ2AD1-3/28VDC 价格&库存

很抱歉,暂时无法提供与“AQ2AD1-3/28VDC”相匹配的价格&库存,您可以联系我们找货

免费人工找货