AQ-E
VDE
1A AC and 3A DC
space saving
PC board terminal type
FEATURES
5.0
.197
28.0
1.102
AQ-E RELAYS
1. Conforms to European safety
standards (VDE0110)
dielectric distance between input and
output
• Creepage distance: Min. 3.0 mm
• Clearances distance: Min. 2.5 mm
2. The small-sized vertical type
28 mm (L)×5 mm (W)×15 mm
1.063 inch (L)×.197 inch (W)×.591 inch
permits high density mounting to PC
board
3. High dielectric strength: 2,500V AC
(between input and output)
15.0
.591
mm inch
TYPES
4. Two load types available:
DC output type (3A)
AC output type (1A)
5. Zero-cross type are availale (AC
type)
The zero-cross type generates minimal
noise
6. Snubber circuit integrated (AC type)
The snubber circuit is integrated to
prevent malfunction caused by the rapid
rise of voltage on the output side, such as
inductive load and current.
TYPICAL APPLICATIONS
Type
Load voltage
AC output
Input voltage
Part No.
5 V DC
AQE12105
75 to 250 V AC
DC output
3 to 60 V DC
12 V DC
AQE12112
24 V DC
AQE12124
5 V DC
AQE34205
12 V DC
AQE34212
24 V DC
AQE34224
• Interface relays for programmable controllers
• Industrial equipment
• Timers and counters
• Air conditioners
ORDERING INFORMATION
Ex. AQE
1
2
1
0
5
Load current
Load voltage
Type
Input voltage
1: 1 A
3: 3 A
2: 75 to 250 V AC
4: 3 to 60 V DC
1: AC output (Zero-cross)
2: DC output
05: 5 V DC
12: 12 V DC
24: 24 V DC
(Note) Standard packing: Carton 20 pcs., Case 1,000 pcs.
ds_61610_en_aqe: 060207D
1
AQ-E
SPECIFICATIONS
Ratings (at 20°C 68°F, Input voltage ripple: 1% or less)
Type
Item
Input
side
AC output
DC output
Part No.
AQE12105
AQE12112
AQE12124
AQE34205
AQE34212
AQE34224
Input voltage
4 to 6 V DC
9.6 to 14.4
V DC
21.6 to 26.4
V DC
4 to 6 V DC
9.6 to 14.4
V DC
21.6 to 26.4
V DC
Input impedance
Approx.
0.5k Ω
Approx.
1.3k Ω
Approx.
3k Ω
Approx.
0.5k Ω
Approx.
1.3k Ω
Approx.
3k Ω
Drop-out voltage,
min.
0.5 V DC
1.2 V DC
2.4 V DC
0.5 V DC
1.2 V DC
2.4 V DC
Reverse voltage
3V
Max. load current
1 A AC
3 A DC
75 to 250 V AC
3 to 60 V DC
45 to 65 Hz
—
20 A
15 A
Max. “OFF-state”
leakage current
1.5 mA (applied 200 V)
10μA
Max. “ON-state”
voltage drop
1.6 V
0.3 V
Min. load curent
20 mA
1 mA
OFF state dV/dt
50 V/μs
—
Max. operating
speed
—
0.5cps.
Load voltage
Frequency
Non-repetitive
surge current
Load
side
Remarks
AC: In one cycle at 60 Hz
DC: 10 ms
at Max. carrying current
at rated operating voltage,
rated load voltage and
current
Characteristics (at 20°C 68°F, Input voltage ripple: 1% or less)
AC output
DC output
Operate time max.
Item
(1/2 cycle of voltage sine wave) + 1 ms
2 ms
Release time, max.
(1/2 cycle of voltage sine wave) + 1 ms
0.4 ms
109 Ω between input and output
Insulation resistance, min.
Breakdown voltage
Vibration
resistance
Shock
resistance
Remarks
Using 500 V DC megger
2,500 Vrms between input and output
Initial for 1 min.
Functional
10 to 55 Hz double amplitude of 1.5 mm
Destructive
10 to 55 Hz double amplitude of 1.5 mm
10 min. for X, Y, Z axes
Functional
Min. 490 m/s {50 G}
5 times each for X, Y, Z
axes
Destructive
Min. 490 m/s2 {50 G}
4 times each for X, Y, Z
axes
2
Ambient temperature
–30°C to +80°C –22°F to +176°F
Storage temperature
–30°C to +100°C –22°F to +212°F
Operational method
1 hour for X, Y, Z axes
Zero-cross (Turn-ON and Turn-OFF)
—
DIMENSIONS
mm inch
15.0 max.
0.5 .591 max.
.020
3.78
.149
0.5
.020–.004
1.2 .047
5.0
.197
–0.1
2-0.5+0.2
-0.1
2-.020+.008
-.004
3.78–0.3
.149–.012
2-1.0
2-.039 –.004
21.42
.843
–0.1
–0.3
21.42–.012
.843
28.0 max.
1.102 max.
2-1
2-. .6 dia
06 .
3d
ia.
2-1
.
2-.02 dia.
47
dia
.
Mounting hole location (Bottom view)
3.5–0.5
–.020
5.04 –0.3
.198 –.012 .138
1.9
.075
5.04
.198
1.2
.047
1.9
.075
Tolerance: ±0.1 ±.004
Schematic
AC type
Input
–
+
Output
General tolerance: ±0.5 ±.020
DC type
Input
–
+
2
Output
+
–
ds_61610_en_aqe: 060207D
AQ-E
REFERENCE DATA
1. Load current vs. ambient temperature
2.-(1) Non-repetitive surge current vs. carrying
time (AC output)
2.-(2) Non-repetitive surge current vs. carrying
time (DC output)
20
Load current, A
3.0
2.5
DC type
2.0
1.5
AC type
1.0
Non-repetitive surge current, A
Non-repetitive surge current, A
3.5
30
20
10
15
10
5
0.5
0
0
20
40
60
80
Ambient temperature, °C
2
30
1.2
25
1.0
=15 mm
.591 inch
0.8
=10 mm
.394 inch
0.6
=5 mm
.197 inch
20
15
(5 V type)
(12 V type)
10
(24 V type)
5
0
10
3 4 5 7 10
20 30 4050 70 100
No. of cycles at 60 Hz
4.-(1) Load current vs. ambient temperature
characteristics for adjacent mounting
(AC output)
Load current, A
Input current, mA
3. Input current vs. input voltage characteristics
1
100
Carrying time, ms
3.5
0.4
3.0
=15 mm
.591 inch
=10mm
.394 inch
=5mm
.197 inch
2.5
2.0
1.5
1.0
0.2
0.5
= Adjacent mounting pitch
= Adjacent mounting pitch
0
5
10
15
20
25
Input voltage, V
30
0
1,000
4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting
(DC output)
Load current, A
0
–30
–20
0
20
40
60
80 100
Ambient temperature, °C
0
-20
0
20
40
60
80 100
Ambient temperature, °C