AQN221L

AQN221L

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    Relay SSR 20mA 32V DC-IN 15A 250V AC-OUT 4-Pin

  • 数据手册
  • 价格&库存
AQN221L 数据手册
AQ-N Discontinued DiscontinuedasasofofAugust August31, 31,2011 2011 Five Types are Lined Up for 10A to 40A AQ-N RELAYS AQ-N FEATURES TYPICAL APPLICATIONS 1. Five types available from 10A to 40A 2. Built-in varistor 3. Includes operation LED (red) 4. Dielectric voltage of 4,000V 5. 4 to 32V DC input voltage 6. Both zero-cross and random types available 1. Molding machine (heater control) 2. Temperature controlled bath (heater control) 3. Printing machines (heater control) 4. Wrapping and packing machine (heater control) 5. Machine tools (Motor control) Product is discontinued. ORDERING INFORMATION A Q N AQ-N Solid State Relays Load current 1: 10 A 2: 15 A 3: 20 A 4: 25 A 6: 40 A Load voltage 1: 75 to 250 V AC, Zero-cross 2: 75 to 250 V AC, Random Input voltage 1: 4 to 32 V DC Function Nil: None V: Built-in varistor L: With LED indication VL: Built-in varistor and with LED indication ds_61617_en_aqn: 010611D 1 AQ-N Discontinued as of August 31, 2011 TYPES 1. Standard type Type Zero-cross type Random type Load current 10A 15A 20A 25A 40A 10A 15A 20A 25A 40A Load voltage 75 to 250V AC 75 to 250V AC Part No. AQN111 AQN211 AQN311 AQN411 AQN611 AQN121 AQN221 AQN321 AQN421 AQN621 2. With LED indication type Type Zero-cross type Random type Load current 10A 15A 20A 25A 40A 10A 15A 20A 25A 40A Load voltage 75 to 250V AC 75 to 250V AC Part No. AQN111L AQN211L AQN311L AQN411L AQN611L AQN121L AQN221L AQN321L AQN421L AQN621L 3. With varistor type Type Zero-cross type Random type Load current 10A 15A 20A 25A 40A 10A 15A 20A 25A 40A Load voltage 75 to 250V AC 75 to 250V AC Part No. AQN111V AQN211V AQN311V AQN411V AQN611V AQN121V AQN221V AQN321V AQN421V AQN621V 4. With varistor and LED indication type Type Zero-cross type Random type Load current 10A 15A 20A 25A 40A 10A 15A 20A 25A 40A Load voltage 75 to 250V AC 75 to 250V AC Part No. AQN111VL AQN211VL AQN311VL AQN411VL AQN611VL AQN121VL AQN221VL AQN321VL AQN421VL AQN621VL Standard packing; carton: 2 pcs., case: 100 pcs. 5. Accessories Type Terminal cover Standard heat sink (10A, 15A and 20A) Standard heat sink (25A) Standard heat sink (40A) Slim heat sink (45mm wide) (Mountable on a DIN rail) DIN rail mounting plate 2 Part No. AQP-NPC AQP-HS-J10A AQP-HS-30/40A AQP-HS-J25A AQP-HS-SJ20A AQP-DP Packaged quantity 2 in a carton, 100 in a case 5 in a carton, 20 in a case 5 in a carton, 20 in a case No carton, 5 in a case No carton, 8 in a case 10 in a carton, 100 in a case ds_61617_en_aqn: 010611D AQ-N Discontinued as of August 31, 2011 RATINGS 1. Ratings (Measurement condition: at 20C 68F, Input ripple: 1% or less) 1) Zero-cross type Type Item Input side Output side Part No. Input voltage Input current Drop-out voltage Max. load current Load voltage Frequency Non-repetitive surge current Max. “OFF-state” leakage current Max. “ON-state” voltage drop Min. load current 10A AQN111 AQN111L AQN111V AQN111VL 15A AQN211 AQN211L AQN211V AQN211VL 10A 15A 100A 150A 20A AQN311 AQN311L AQN311V AQN311VL 4 to 32V Max. 20mA Min. 1V 20A 75V to 250V 45Hz to 65Hz 200A Max. 10mA Min. 1.6V 100mA 25A AQN411 AQN411L AQN411V AQN411VL 40A AQN611 AQN611L AQN611V AQN611VL Remarks *1 *1 25A 40A *2 250A 400A In one cycle at 60Hz *3 at 60Hz at Max. carrying current *4 25A AQN421 AQN421L AQN421V AQN421VL 40A AQN621 AQN621L AQN621V AQN621VL Notes: *1. Please refer to REFERENCE DATA, “3. Input current vs. input voltage”. *2. Please refer to REFERENCE DATA, “1. Load current vs. ambient temperature”. *3. Please refer to REFERENCE DATA, “2. Non-repetitive surge current vs. carrying time”. *4. When the load current is less than the rated minimum load current, please refer to Cautions for Use 2) Random type Type Item Input side Output side Part No. Input voltage Input current Drop-out voltage Max. load current Load voltage Frequency Non-repetitive surge current Max. “OFF-state” leakage current Max. “ON-state” voltage drop Min. load current 10A AQN121 AQN121L AQN121V AQN121VL 15A AQN221 AQN221L AQN221V AQN221VL 10A 15A 100A 150A 20A AQN321 AQN321L AQN321V AQN321VL 4 to 32V Max. 20mA Min. 1V 20A 75V to 250V 45Hz to 65Hz 200A Max. 10mA Min. 1.6V 100mA Remarks *1 *1 25A 40A *2 250A 400A In one cycle at 60Hz *3 at 60Hz at Max. carrying current *4 Notes: *1. Please refer to REFERENCE DATA, “3. Input current vs. input voltage”. *2. Please refer to REFERENCE DATA, “1. Load current vs. ambient temperature”. *3. Please refer to REFERENCE DATA, “2. Non-repetitive surge current vs. carrying time”. *4. When the load current is less than the rated minimum load current, please refer to Cautions for Use. 2. Characteristics (Measurement condition: at 20C 68F, Input ripple: 1% or less) 1) Zero-cross type Type Part No. Operate time, max. Release time, max. Insulation resistance, min. Breakdown voltage Vibration resistance (Functional) Shock resistance (Functional) Ambient temperature Storage temperature Operational method 10A AQN111 AQN111L AQN111V AQN111VL 15A 20A 25A 40A AQN211 AQN311 AQN411 AQN611 AQN211L AQN311L AQN411L AQN611L AQN211V AQN311V AQN411V AQN611V AQN211VL AQN311VL AQN411VL AQN611VL (1/2 cycle of voltage sine wave) + 1ms (1/2 cycle of voltage sine wave) + 1ms 100M between input and output 4,000 Vrms between input and output; 2,500 Vrms among input, output and case 10 to 55Hz double amplitude of 1.5mm Min. 980 m/s2 –20C to +80C –4F to +176F*2 –25C to +85C –13F to +185F Zero-cross (Turn-ON and Turn-OFF) Remarks Using 500 V DC megger for 1min. X, Y, Z axes X, Y, Z axes Non-condensing at low temperatures 2) Random type Type Part No. Operate time, max. Release time, max. Insulation resistance, min. Breakdown voltage Vibration resistance (Functional) Shock resistance (Functional) Ambient temperature Storage temperature Operational method ds_61617_en_aqn: 010611D 10A AQN121 AQN121L AQN121V AQN121VL 15A AQN221 AQN221L AQN221V AQN221VL 20A 25A 40A AQN321 AQN421 AQN621 AQN321L AQN421L AQN621L AQN321V AQN421V AQN621V AQN321VL AQN421VL AQN621VL 1ms (1/2 cycle of voltage sine wave) + 1ms 100M between input and output 4,000 Vrms between input and output; 2,500 Vrms among input, output and case 10 to 55Hz double amplitude of 1.5mm Min. 980 m/s2 –20C to +80C –4F to +176F –25C to +85C –13F to +185F Random (Turn-ON), Zero-cross (Turn-OFF) Remarks Using 500 V DC megger for 1min. X, Y, Z axes X, Y, Z axes Non-condensing at low temperatures 3 AQ-N Discontinued as of August 31, 2011 REFERENCE DATA 1. Load current vs. ambient temperature Use load current within range specified in the figure below. Tested condition Without external heat sink If the mounting surface is not metallic and a heat sink is not used, expose the bottom surface and plate surface to improve heat dissipation. (2) 15A type (3) 20A type 25 0 100 (5) 40A type 20 40 60 80 Ambient temperature, °C 35 Load current, A 25 When using a steel plate of 150×150×t1.6 (mm) or greater 20 When using a steel plate of 100×100×t1.6 (mm) or greater 40 A type 25 A type 20 20 A type 15 15 A type 10 15 10 A type 10 0 -20 0 20 40 60 80 Ambient temperature, °C 100 0 -20 0 20 40 60 80 Ambient temperature, °C 100 20A type 15A type 10 A type 400 40A type 25A type 300 200 100 5 When using as stand-alone When using a steel plate of 75×75×t1.6 (mm) or greater 5 (mm) or greater When using as stand-alone 500 25 When using AQP-HS-30/40A 30 (mm) or greater When using a steel 2. Non-repetitive surge current vs. carrying time Non-repetitive surge current, A When using AQP-HS-J25A When using a steel 15 plate of 150×150×t1.6 0 100 30 40 20 5 0 When using AQP-HS-30/40A 10 plate of 100×100×t1.6 (6) Data when mounted on an AQP-HS-SJ20A slim heat sink 45 Load current, A When using a steel plate of 75×75×t1.6 (mm) or greater -20 20 40 60 80 100 Ambient temperature, °C When using AQP-HS-J10A When using as stand-alone 5 20 40 60 80 Ambient temperature, °C Load current, A Load current, A Load current, A When using AQP-HS-J10A When using a steel plate of 150×150×t1.6 (mm) or greater 15 When using a steel plate of 100×100×t1.6 (mm) or greater 10 0 (4) 25A type 30 5 0 6 25 When using as stand-alone -20 8 0 -20 20 10 When using AQP-HS-J10A or a steel plate of 100×100×t0.8 (mm) or greater 10 2 When using AQP-HS-J10A or a steel plate of 150×150×t1.6 (mm) or greater When using a steel plate of 150×150×t1.6 (mm) or greater 0 12 When using as 4 stand-alone 20 15 (1) 10A type Load current, A With external heat sink 1) (1) 10A, 15A, 20A type Shown with standard heat sink (AQP801) (2) Shown with 25A type standard heat sink (AQP804) (3) Shown with 40A type standard heat sink (AQP806) (4) In the case of the AQP812 slim heat-sink types, characteristics data are available for each type. Please refer to (6). 2) If attached to a heat sink, use a heat conductive compound (Ex. Toshiba silicone YG6111 or TSK5303) of similar coating to improve cooling. 0 20 40 60 80 Ambient temperature, °C 100 0 1 10 No. of cycles at 60 Hz 100 3. Input current vs. input voltage 10A, 15A, 20A, 25A, 40A common 16 Input current, mA 14 12 10 8 With LED 6 Without LED 4 2 0 4 5 10 15 20 25 30 Input voltage, V 35 ds_61617_en_aqn: 010611D AQ-N Discontinued as of August 31, 2011 DIMENSIONS (mm inch) CAD Data Data from our Web site. Download CAD External dimensions * The right figure is the LED indication type. The standard type has the same dimensions. Schematic 58.0 2.283 43.2 1.701 2-M3 2-M4 . dia ia. 4.5 77 d .1 CAD Data 45.0 25.4 4.5 1.772 1.000 .177 11.4 .449 Input power source _ + 27.9 1.098 4 1 3 2 Load Load power source Mounting dimensions 47.5 +0.2 −0.1 1.870 +.008 −.004 2-4.3 dia. or M4 2-.069 dia. or M4 47.5 1.870 27.0 max. 1.063 max. 20.0 .787 22.0 .866 ACCESSORIES AQP-HS-SJ20A Slim Heat Sink 100 90 78 40 CAD Data Mounting dimensions 3.937 3.543 3.071 1.575 2-4.6 dia. or M4 2-.181 dia. or M4 5-M4 (Effective screw depth: 6mm .236inch) 6 .236 6 30 .236 1.181 4.6 dia. .181 dia. 30 47.6 1.874 1.181 90±0.2 3.543±.008 4.6×5.6 elliptical hole .181×.220 45 1.772 78 83 3.071 3.268 1.6 .063 AQP812 70707 Note: When using on a DIN rail, please install so that the “A” part is on top. “A” part AQP-HS-J10A Standard Heat Sink 4.4 .173 CAD Data 50 1.969 4.4 .173 R2.2 .087 Mounting dimensions 4-M4 or 4.4 dia. 4-M4 or .173 dia. 2 .079 1.5 .059 2-M4 47.6 1.874 100 3.937 ds_61617_en_aqn: 010611D +0.5 100 −1.5 33.3 +.020 3.937 −.059 1.311 80 3.150 11.1 .437 54 2.126 90 3.543 2 .079 24.5 .965 28.5 9 .354 1.122 45 1.772 90±0.1 3.543±.004 1.5 .059 50±0.2 1.969±.008 5 AQ-N Discontinued as of August 31, 2011 AQP-HS-30/40A Standard Heat Sink CAD Data 50 1.969 4.4 .173 Mounting dimensions 4.4 .173 2 .079 4-M4 or 4.4 dia. 4-M4 or .173 dia. 11.1 .437 R 2.2 .087 3-M4 90 3.543 80 3.150 33.3 100+0.5 −1.5 1.311 3.937+.020 −.059 54 2.126 47.6 1.874 90±0.1 3.543±.004 1.5 .059 2 .079 56 2.205 150 5.906 1.5 .059 24.5 .965 28.5 1.122 45 1.772 9 .354 General tolerance: 0.5.020 50±0.2 1.969±.008 44- R2. R. 5 09 8 AQP-HS-J25A Standard Heat Sink CAD Data Mounting dimensions 4-M4.5 or 5 dia. 4-M4.5 or .197 dia. 3M 4 5 .197 30 1.181 47.5 119 150 1.870 4.685 5.906 119±0.1 4.685±.004 132±0.1 5.197±.004 132 5.197 2 .079 7 .276 52 2.047 3 .118 46 1.811 64 2.520 13 .512 82 3.228 100 3.937 120 4.724 142 5.591 AQP-DP DIN Rail Mounting Plate AT8-DLA1 Mounting Rail CAD Data 13.6 .535 CAD Data M4 M4 56 2.205 47.6 1.874 M4 18.1 .713 44 1.732 1,000 39.37 70 2.765 86 3.386 General tolerance: 0.5 .020 5.5 .217 5 .197 15 10 15 .591 .394 .591 2.75R 15 10 15 .108R .591 .394 .591 40-5.5×15 slot 40-.217×.591 slot 6 35 1.378 24 1.5 5 .945 .059 .197 27 1.063 7.5 .295 ds_61617_en_aqn: 010611D AQ-N Discontinued as of August 31, 2011 ATA4806 Fastening Plate AQP-NPC Terminal Cover CAD Data CAD Data 4-7 dia. 4-.276 dia. 12 .472 44.6 1.756 27.9 1.098 1.5 .059 10 .394 57.5 43.2 2.264 1.701 50 M4 1.969 10 .394 UP ATA4806 25.4 1.000 10 .394 2 .079 24 .945 Cautions for Use ds_61617_en_aqn: 010611D 7
AQN221L 价格&库存

很抱歉,暂时无法提供与“AQN221L”相匹配的价格&库存,您可以联系我们找货

免费人工找货