Discontinuedas
asofofAugust
August31,
31,2011
2011
Discontinued
(10A, 15A, 20A type)
10A to 40A
hockey puck type
AQ-R
(30A, 40A type)
AQ-R RELAYS
AQ-R
FEATURES
APPLICATIONS
1. Two types of terminal shape: Plugin terminal and Screw terminal (30 A,
40 A is screw terminal types only)
2. Flat type of SSR possible by
aluminium printed circuit board
3. High dielectric strength of 1,500 V
between input and output. 4,000 V
available for 10A, 15A, 20A devices.
4. Heat sink and DIN mounting rail and
terminal cover are available as
accessories
1. Molding machine (heater control)
2. Temperature controlled bath (heater
control)
3. Printing machine (heater control)
4. Machine tool (motor control)
Product is discontinued.
TYPES
1. Plug-in terminal type
Type
Load voltage
75 to 125V AC
Zero-cross 10 A
75 to 250V AC
75 to 125 V AC
Zero-cross 15 A
75 to 250 V AC
75 to 125 V AC
Zero-cross 20 A
75 to 250 V AC
Input voltage
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
Standard (1,500V AC)
Part No.
AQR10A1-Z4/6VDC
AQR10A1-Z10/18VDC
AQR10A1-Z18/28VDC
AQR10A2-Z4/6VDC
AQR10A2-Z10/18VDC
AQR10A2-Z18/28VDC
AQR15A1-Z4/6VDC
AQR15A1-Z10/18VDC
AQR15A1-Z18/28VDC
AQR15A2-Z4/6VDC
AQR15A2-Z10/18VDC
AQR15A2-Z18/28VDC
AQR20A1-Z4/6VDC
AQR20A1-Z10/18VDC
AQR20A1-Z18/28VDC
AQR20A2-Z4/6VDC
AQR20A2-Z10/18VDC
AQR20A2-Z18/28VDC
Reinforced (4,000V AC)
Part No.
—
—
—
AQR10A2-ZV4/6VDC
AQR10A2-ZV10/18VDC
AQR10A2-ZV18/28VDC
—
—
—
AQR15A2-ZV4/6VDC
AQR15A2-ZV10/18VDC
AQR15A2-ZV18/28VDC
—
—
—
AQR20A2-ZV4/6VDC
AQR20A2-ZV10/18VDC
AQR20A2-ZV18/28VDC
Standard (1,500V AC)
Part No.
AQR10A1-S-Z4/6VDC
AQR10A1-S-Z10/18VDC
AQR10A1-S-Z18/28VDC
AQR10A2-S-Z4/6VDC
AQR10A2-S-Z10/18VDC
AQR10A2-S-Z18/28VDC
AQR15A1-S-Z4/6VDC
AQR15A1-S-Z10/18VDC
AQR15A1-S-Z18/28VDC
AQR15A2-S-Z4/6VDC
AQR15A2-S-Z10/18VDC
AQR15A2-S-Z18/28VDC
AQR20A1-S-Z4/6VDC
AQR20A1-S-Z10/18VDC
AQR20A1-S-Z18/28VDC
AQR20A2-S-Z4/6VDC
AQR20A2-S-Z10/18VDC
AQR20A2-S-Z18/28VDC
AQR30A2-S-Z4/6VDC
AQR30A2-S-Z10/18VDC
AQR30A2-S-Z18/28VDC
AQR40A2-S-Z4/6VDC
AQR40A2-S-Z10/18VDC
AQR40A2-S-Z18/28VDC
Reinforced (4,000V AC)
Part No.
—
—
—
AQR10A2-S-ZV4/6VDC
AQR10A2-S-ZV10/18VDC
AQR10A2-S-ZV18/28VDC
—
—
—
AQR15A2-S-ZV4/6VDC
AQR15A2-S-ZV10/18VDC
AQR15A2-S-ZV18/28VDC
—
—
—
AQR20A2-S-ZV4/6VDC
AQR20A2-S-ZV10/18VDC
AQR20A2-S-ZV18/28VDC
—
—
—
—
—
—
2. Screw-terminal type
Type
Load voltage
75 to 125 V AC
Zero-cross 10 A
75 to 250 V AC
75 to 125 V AC
Zero-cross 15 A
75 to 250 V AC
75 to 125 V AC
Zero-cross 20 A
75 to 250 V AC
Zero-cross 30 A
75 to 250 V AC
Zero-cross 40 A
75 to 250 V AC
ds_61608_en_aqr: 010611D
Input voltage
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
1
AQ-R
Discontinued as of August 31, 2011
ORDERING INFORMATION
Ex. AQR
10A
1
S
Z
4/6VDC
Load current
Load voltage
Terminal shape
Type
Input voltage
10 A, 15 A, 20 A, 30 A, 40 A
1: 75 to 125 V AC
2: 75 to 250 V AC
Nil: Plug-in terminal
S: Screw terminal
Z: Zero-cross type (1,500 V)
ZV: Zero-cross type (4,000 V)
4/6, 10/18, 18/28 V DC
Note: Standard packing: Carton 10 pcs., Case: 100 pcs.
SPECIFICATIONS
1. Ratings (at 20C 68F, Input ripple: 1% or less)
1) 10 A type
Part No.
AQR10A1-Z4/
6VDC
AQR10A1-Z10/
18VDC
AQR10A1-Z18/
28VDC
AQR10A2-Z4/
6VDC
AQR10A2-ZV4/
6VDC
AQR10A2-Z10/
18VDC
AQR10A2-ZV10/
18VDC
AQR10A2-Z18/
28VDC
AQR10A2-ZV18/
28VDC
AQR10A2-S-Z10/
18VDC
AQR10A2-SZV10/18VDC
10 to 18V DC
Approx. 0.86 k
AQR10A2-S-Z18/
28VDC
AQR10A2-SZV18/28VDC
18 to 28V DC
Approx. 1.36 k
AQR10A1-S-Z4/
6VDC
AQR10A1-S-Z10/
18VDC
AQR10A1-S-Z18/
28VDC
AQR10A2-S-Z4/
6VDC
AQR10A2-S-ZV4/
6VDC
4 to 6V DC
Approx. 0.26 k
10 to 18V DC
Approx. 0.86 k
18 to 28V DC
Approx. 1.36 k
4 to 6V DC
Approx. 0.26 k
Items
Input
side
Input voltage
Input impedance
Drop-out voltage,
min.
1V
Max. load current
Load
side
See
“REFERENCE
DATA 1”
10 A
Load voltage
Frequency
Repetitive peak
voltage
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Remarks
75 to 125 V AC
75 to 250 V AC
45 to 65 Hz
400 V
600 V
In one cycle at
60 Hz
100 A
2.5 mA (when 100 V AC applied)
5 mA (when 200 V AC applied)
at max.
carrying current
1.6 V
Min. load current
OFF-state dV/dt
at 60 Hz
100 mA
100 V/s
2) 15 A type
Part No.
AQR15A1-Z4/
6VDC
AQR15A1-Z10/
18VDC
AQR15A1-Z18/
28VDC
AQR15A1-S-Z4/
6VDC
AQR15A1-S-Z10/
18VDC
AQR15A1-S-Z18/
28VDC
4 to 6V DC
Approx. 0.26 k
10 to 18V DC
Approx. 0.86 k
18 to 28V DC
Approx. 1.36 k
Items
Input
side
Input voltage
Input impedance
Drop-out voltage,
min.
Load
side
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
OFF-state dV/dt
2
AQR15A2-Z10/
18VDC
AQR15A2-ZV10/
18VDC
AQR15A2-S-Z10/
18VDC
AQR15A2-SZV10/18VDC
4 to 6V DC
Approx. 0.26 k
10 to 18V DC
Approx. 0.86 k
AQR15A2-Z18/
28VDC
AQR15A2-ZV18/
28VDC
AQR15A2-S-Z18/
28VDC
AQR15A2-SZV18/28VDC
18 to 28V DC
Approx. 1.36 k
Remarks
1V
Max. load current
Load voltage
Frequency
Repetitive peak
voltage
Non-repetitive
surge current
AQR15A2-Z4/
6VDC
AQR15A2-ZV4/
6VDC
AQR15A2-S-Z4/
6VDC
AQR15A2-S-ZV4/
6VDC
See
“REFERENCE
DATA 1”
15 A
75 to 125 V AC
75 to 250 V AC
45 to 65 Hz
400 V
600 V
In one cycle at
60 Hz
150 A
2.5 mA (when 100 V AC applied)
5 mA (when 200 V AC applied)
1.6 V
at 60 Hz
at max.
carrying current
100 mA
100 V/s
ds_61608_en_aqr: 010611D
AQ-R
Discontinued as of August 31, 2011
3) 20 A type
Part No.
AQR20A1-Z4/
6VDC
AQR20A1-Z10/
18VDC
AQR20A1-Z18/
28VDC
AQR20A1-S-Z4/
6VDC
AQR20A1-S-Z10/
18VDC
AQR20A1-S-Z18/
28VDC
4 to 6V DC
Approx. 0.26 k
10 to 18V DC
Approx. 0.86 k
18 to 28V DC
Approx. 1.36 k
Items
Input
side
Input voltage
Input impedance
Drop-out voltage,
min.
AQR20A2-Z10/
18VDC
AQR20A2-ZV10/
18VDC
AQR20A2-S-Z10/
18VDC
AQR20A2-SZV10/18VDC
10 to 18V DC
Approx. 0.86 k
AQR20A2-Z18/
28VDC
AQR20A2-ZV18/
28VDC
AQR20A2-S-Z18/
28VDC
AQR20A2-SZV18/28VDC
18 to 28V DC
Approx. 1.36 k
Remarks
1V
Max. load current
Load
side
AQR20A2-Z4/
6VDC
AQR20A2-ZV4/
6VDC
AQR20A2-S-Z4/
6VDC
AQR20A2-S-ZV4/
6VDC
4 to 6V DC
Approx. 0.26 k
See
“REFERENCE
DATA 1”
20 A
Load voltage
Frequency
Repetitive peak
voltage
Non-repetitive
surge current
75 to 125 V AC
75 to 250 V AC
45 to 65 Hz
400 V
600 V
In one cycle at
60 Hz
200 A
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
2.5 mA (when 100 V AC applied)
5 mA (when 200 V AC applied)
at 60 Hz
at max.
carrying current
1.6 V
Min. load current
OFF-state dV/dt
100 mA
100 V/s
4) 30 A type and 40 A type
Part No.
Items
Input
side
Input voltage
Input impedance
Drop-out voltage,
min.
AQR30A2-S-Z4/
6VDC
4 to 6V DC
Approx. 0.26 k
Max. load current
Load
side
Load voltage
Frequency
Non-repetitive
surge current
AQR30A2-S-Z10/
18VDC
10 to 18V DC
Approx. 0.86 k
AQR30A2-S-Z18/
28VDC
18 to 28V DC
Approx. 1.36 k
AQR40A2-S-Z4/
6VDC
4 to 6V DC
Approx. 0.26 k
AQR40A2-S-Z10/
18VDC
10 to 18V DC
Approx. 0.86 k
AQR40A2-S-Z18/
28VDC
18 to 28V DC
Approx. 1.36 k
Remarks
1V
30 A
40 A
See
“REFERENCE
DATA 1”
400 A
In one cycle at
60 Hz
75 to 250 V AC
45 to 65 Hz
300 A
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
5 mA (when 200 V AC applied)
1.6 V
Min. load current
at 60 Hz
at max.
carrying current
120 mA
2. Characteristics (at 20C 68F, Input ripple: 1% or less)
Type
Item
Operate time, max.
Release time, max.
Insulation resistance, min., Initial
Breakdown voltage
Vibration
resistance
Functional
Destructive
Functional
Destructive
Ambient temperature
Storage temperature
Operational method
Shock
resistance
Zero-cross type
Standard type
Reinforced type
(1/2 cycle of voltage sine wave) + 1 ms
(1/2 cycle of voltage sine wave) + 1 ms
100 M between input, output and case
1,500 V AC between input, output and case
4,000 V AC between input, output and case
10 to 55 Hz at double amplitude of 2 mm*
10 to 55 Hz at double amplitude of 2 mm*
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
–20C to +80C –4F to +176F
–25C to +85C –13F to +185F
Zero-cross (Turn-ON and Turn-OFF)
Remarks
by 500V DC megger
For 1 min.
1 hour for X, Y, Z axes
10 minutes for X, Y, Z axes
5 time each for X, Y, Z axes
4 time each for X, Y, Z axes
Note: * 30 A and 40 A type is 10 to 55 Hz at double amplitude of 1.5 mm.
ds_61608_en_aqr: 010611D
3
AQ-R
Discontinued as of August 31, 2011
DIMENSIONS(mm inch)
CAD Data
Data from our Web site.
Download CAD
1. Plug-in terminal
Schematic
CAD Data
Input power
source
_
+
44.8
26 1.764
1.024
9
.354
Mounting hole
Conform to AMP plug-in terminal
#110 series receptacle
Load power
source
Mounting dimensions
(Bottom view)
2-4.4 dia.
2-.173 dia.
47.6
1.874
59
2.323
Load
47.6 – 0.1
1.874 – .004
2-4.3 dia. or M4
2-.169 dia.
Conform to AMP plug-in terminal
#250 series receptacle
Max. 15
Max. .591
Max. 7.5
Max. .295
Max. 12.5
Max. .492
2. Screw terminal
Schematic
CAD Data
Input power
source
4-M4
screw terminal
_
+
Load
Load power
source
44.8
26 1.764
1.024
9
.354
Mounting hole
Mounting dimensions
(Bottom view)
2-4.4 dia.
2-.173 dia.
45.0
1.772
47.6
1.874
59
2.323
47.6 – 0.1
1.874 – .004
2-4.3 dia. or M4
2-.169 dia.
Max. 17
Max. .669
Max. 7.5
Max. .295
max. 12.5
Max. .492
ACCESSORIES
Heat sink (For 10 A, 15A and 20 A)
Mounting dimensions
(Bottom view)
CAD Data
4.4
.173
50
1.969
4.4
.173
R2.2
.087
2
.079
4-M4 or 4.4 dia
1.5
.059
2-M4
AQP-HS-20A
9.5
33.3 100 +-1.5
1.311 3.937 +.929
-.059
80
3.150
11.1
.437
54
2.126
90
3.543
2
.079
47.6
1.874
100
3.937
24.5
.965
28.5
9
1.122
.354
45
1.772
90 – 0.1
3.543 – .004
1.5
.059
50 – 0.2
1.969 – .008
General tolerance: 0.5
.020
4
ds_61608_en_aqr: 010611D
AQ-R
Discontinued as of August 31, 2011
Heat sink (For 30 A, 40 A)
mm inch
CAD Data
Mounting dimensions
(Bottom view)
50
1.969
4.4
.173
4.4
.173
4-M4 or 4.4 dia
11.1
.437
R 2.2 .087
3-M4
90
3.543
2
.079
80
3.150
33.3
100+0.5
−1.5
1.311 3.937+.020 90 – 0.1
−.0593.543 – .004
54
2.126
47.6
1.874
1.5
.059
AQP-HS-30/40A
2
.079
56
2.205
150
5.906
1.5
.059
50 – 0.2
1.969 – .008
24.5
.965
28.5
1.122
45
1.772
9
.354
General tolerance: 0.5
.020
With terminal cover
CAD Data
59
2.323
1.5
.059
11.5
.453
47
1.850
5.5
.217
1.5
.059
AQP-PC
24.5
.965
General tolerance: 0.5 .020
DIN rail mounting plate
Mounting rail
CAD Data
CAD Data
13.6
.535
M4
M4
56
2.205
47.6
1.874
M4
18.1
.713
44
1.732
AT8-DLA1
AQP-DP
1,000
39.37
70
2.765
86
3.386
5.5
.217
5
.197
15 10 15
.591 .394 .591
2.75R 15 10 15
.108R .591 .394 .591
40-5.5 × 15 slot
40-.217 × .591 slot
35
1.378 24
5
.945 1.5
.059
.197
General tolerance: 0.5 .020
ds_61608_en_aqr: 010611D
27
1.063
7.5
.295
5
AQ-R
Discontinued as of August 31, 2011
Fastening plate
mm inch
CAD Data
50
M4 1.969
12
.472
10
.394
ATA4806
UP
ATA4806
10
.394
REFERENCE DATA
1. Load current vs. ambient temperature
Use load current within range specified in the figure below.
Tested condition:
With external heat sink
1) (1) 10 A, 15A, 20 A type
• A heat sink; optional heat sink (AQP801) or
a 1501503.2 mm aluminum sheet
(painted black)
(2) 30 A, 40 A type
Shown with standard heat sink (AQP804)
2) If attached to a heat sink, use a heatconductive compound or similar coating to
improve cooling.
Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
The graphs show the characteristics when the
relay is mounted as shown in the right figure.
(2) 15 A type
(3) 20 A type
(1) 10 A type
3 mm or
greater
Washers are added
to lift the relay.
Load current, A
Hole for radiation
(40×35 mm)
10
With external
heat sink
8
6
Without external heat sink
4
2
0
-30
0
20
40
60
80
Ambient temperature, °C
(4) 30 A type
50
16
15
12
Without external heat sink
Load current, A
Load current, A
With external
With external
heat sink
16
12
Without external heat sink
8
7
6
4
8
2
0
-30
2
0
-30
40
Load current, A
20
20
20
40
60
80
Ambient temperature, °C
(5) 40 A type
20
Without external heat sink
10
4
0
With external
heat sink
30
0
0
-30
20
40
60
80
Ambient temperature, °C
2-1. Non-repetitive surge current vs. carrying
time (10 A type)
0
20
40
60
80
Ambient temperature, °C
2-2. Non-repetitive surge current vs. carrying
time (15 A type)
Load current, A
30
20
Without external heat sink
10
Non-repetitive surge current, A
With external
heat sink
40
Non-repetitive surge current, A
50
220
200
180
160
140
120
100
80
60
40
6
0
20
40
60
80
Ambient temperature, °C
0
200
180
160
140
120
100
80
60
40
20
0
-30
220
20
1
2
3 4 5 7 10
20 30 40 50 70 100
No. of cycles at 60 Hz
0
1
2
3 4 5 7 10
20 30 40 50 70 100
No. of cycles at 60 Hz
ds_61608_en_aqr: 010611D
AQ-R
Discontinued as of August 31, 2011
2-3. Non-repetitive surge current vs. carrying
time (20 A type)
2-4. Non-repetitive surge current vs. carrying
time (30 A, 40 A type)
3. Input current vs. input voltage
(10 A, 15 A, 20 A, 30 A, 40 A common)
30
200
180
160
140
120
100
80
60
25
400
300
40A type
30A type
200
(4 to 6 V)
20
(10 to 18 V)
15
(18 to 28 V)
10
100
40
Input current, mA
Non-repetitive surge current, A
Non-repetitive surge current, A
500
220
5
20
0
1
2
3 4 5 7 10
20 30 40 50 70 100
No. of cycles at 60 Hz
0
1
2 3 4 5 7 10 20 304050 70 100
No. of cycles at 60 Hz
0
0
5
10
20
15
Input voltage, V
25
30
Cautions for Use
ds_61608_en_aqr: 010611D
7