0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AQW454AX

AQW454AX

  • 厂商:

    NAIS(松下)

  • 封装:

    8-SMD(0.300",7.62mm)

  • 描述:

    RELAY OPTO AC/DC 400V 120MA 8SMD

  • 数据手册
  • 价格&库存
AQW454AX 数据手册
HE (High-function Economy) Type [2-Channel (Form B) Type] FEATURES 9.78 .385 6.4 .252 3.9±0.2 .154±.008 9.78 .385 6.4 .252 3.6±0.2 .142±.008 PhotoMOS RELAYS 5. Low-level off state leakage current The SSR has an off state leakage current of several miliamperes, whereas the PhotoMOS relay has only 100 pA even with the rated load voltage of 400 V (AQW454). 6. Low thermal electromotive force (Approx. 1 µV) mm inch 1 2 3 4 8 7 6 5 1. Compact 8-pin DIP size The device comes in a compact (W) 6.4×(L) 9.78×(H) 3.9 mm (W) .252×(L) .385×(H) .154 inch , 8-pin DIP size (through hole terminal type). 2. Applicable for 2 Form B use as well as two independent 1 Form B use. 3. Controls low-level analog signals PhotoMOS relays feature extremely low closed-circuit offset voltage to enable control of low-level analog signals without distortion. 4. High sensitivity, low ON resistance Can control a maximum 0.16 A (AQW454) load current with a 5 mA input current. Low ON resistance of 16 Ω (AQW454). Stable operation because there are no metallic contact parts. TYPICAL APPLICATIONS • Security equipment • High-speed inspection machine • Measuring equipment • Telecommunication equipment • Sensors TYPES Part No. Output rating* Type Load voltage Load current Through hole terminal Tube packing style Surface-mount terminal Tape and reel packing style Picked from the Picked from the 1/2/3/4-pin side 5/6/7/8-pin side AQW454AX AQW454AZ Packing quantity Tube 1 tube contains 40 pcs. 1 batch contains 400 pcs. Tape and reel AC/DC 400 V 120 mA AQW454 AQW454A 1,000 pcs *Indicate the peak AC and DC values. Note: For space reasons, the package type indicator "X" and "Z" are omitted from the seal. RATING 1. Absolute maximum ratings (Ambient temperature: 25°C 77°F) Item LED forward current LED reverse voltage Peak forward current Power dissipation Load voltage (peak AC) Continuous load current Symbol IF VR IFP Pin VL IL Ipeak Pout PT Viso Operating Storage Topr Tstg AQW454(A) 50 mA 3V 1A 75 mW 400 V 0.12 A (0.16 A) 0.36 A 800 mW 850 mW 1,500 V AC –40°C to +85°C –40°F to +185°F –40°C to +100°C –40°F to +212°F Remarks Input f = 100 Hz, Duty factor = 0.1% Output Peak load current Power dissipation Total power dissipation I/O isolation voltage Temperature limits A connection: Peak AC, DC ( ): for one 1b-circuit A connection: 100 ms (1 shot), VL = DC Between input and output/between contact sets Non-condensing at low temperatures 171 AQW454 2. Electrical characteristics (Ambient temperature: 25°C 77°F) Item LED operate (OFF) current Input LED reverse (ON) current LED dropout voltage On resistance Output Off state leakage current Operate (OFF) time* Reverse (ON) time* Maximum Maximum Typical Maximum Typical Maximum Typical Maximum Minimum ILeak Toff Ton Ciso Riso Typical Maximum Minimum Typical Typical Maximum Typical Ron Symbol IFoff IFon VF AQW454(A) 0.9 mA 3 mA 0.4 mA 0.8 mA 1.14 V (1.25 V at IF = 50 mA) 1.5 V 11 Ω 16 Ω 1 µA 1.2 ms 2 ms 0.36 ms 1 ms 0.8 pF 1.5 pF 1,000 MΩ Condition IL = 120 mA IL = 120 mA IF = 5 mA IF = 0 mA IL = 120 mA Within 1 s on time IF = 5 mA VL = 400 V IF = 0 mA ¨ 5 mA IL = 120 mA IF = 5 mA ¨ 0 mA IL = 120 mA f = 1 MHz VB = 0 500 V DC For type of connection, see page 33. Switching speed Transfer characteristics I/O capacitance Initial I/O isolation resistance Note: Recommendable LED forward current IF = 5 mA. *Operate/Reverse time Input Output 10% 90% Toff Ton s For Dimensions, see Page 27. s For Schematic and Wiring Diagrams, see Page 33. s For Cautions for Use, see Page 36. REFERENCE DATA 1. Load current vs. ambient temperature characteristics Allowable ambient temperature: –40°C to +85°C –40°F to +185°F 250 2. On resistance vs. ambient temperature characteristics Measured portion: between terminals 5 and 6, 7 and 8; LED current: 0 mA; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) 16 3. Operate (OFF) time vs. ambient temperature characteristics LED current: 5 mA; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) 5 Operate (OFF) time, ms Load current, mA 150 On resistance, Ω 200 14 4 12 3 100 10 2 50 8 1 0 –40 –20 0 20 40 60 8085 100 Ambient temperature, °C –40 –20 0 20 40 60 8085 Ambient temperature, °C 0 –40 –20 0 20 40 60 8085 Ambient temperature, °C 172 AQW454 4. Reverse (ON) time vs. ambient temperature characteristics LED current: 5 mA; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) 2.5 5. LED operate (OFF) current vs. ambient temperature characteristics Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) LED operate (OFF) current, mA 5 6. LED reverse (ON) current vs. ambient temperature characteristics Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) 5 LED reverse (ON) current, mA Reverse (ON) time, ms 2.0 4 4 1.5 3 3 1.0 2 2 0.5 1 1 0 –40 –20 0 20 40 60 8085 0 –40 –20 0 20 40 60 8085 0 –40 –20 Ambient temperature, °C Ambient temperature, °C 0 20 40 60 8085 Ambient temperature, °C 7. LED dropout voltage vs. ambient temperature characteristics LED current: 5 to 50 mA 1.4 8. Voltage vs. current characteristics of output at MOS portion Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25°C 77°F Current, mA 150 100 50 9. Off state leakage current Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25°C 77°F 1.3 Off state leakage current, A 10 –3 LED dropout voltage, V 10 –6 1.2 50mA 30mA 20mA 10mA 5mA 1.0 0 –40 –20 0 20 40 60 8085 Ambient temperature, °C –3 –2 –1 0 –50 –100 1 2 Voltage, V 3 1.1 10 –9 10 –12 –150 0 20 40 60 80 Load voltage, V 100 10. LED forward current vs. operate (OFF) time characteristics Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC); Ambient temperature: 25°C 77°F 5 11. LED forward current vs. reverse (ON) time characteristics Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC); Ambient temperature: 25°C 77°F 1.0 12. Applied voltage vs. output capacitance characteristics Measured portion: between terminals 5 and 6, 7 and 8; Frequency: 1 MHz; Ambient temperature: 25°C 77°F 200 Output capacitance, pF Operate (OFF) time, ms 4 Reverse (ON) time, ms 0.8 3 0.6 100 2 0.4 1 0.2 0 0 10 20 30 40 50 60 0 0 10 20 30 40 50 60 0 0 10 LED forward current, mA LED forward current, mA 20 30 40 50 Applied voltage, V 60 5/7/2001 All Rights Reserved, © Copyright Matsushita Electric Works, 173 Ltd. Go To Online Catalog
AQW454AX 价格&库存

很抱歉,暂时无法提供与“AQW454AX”相匹配的价格&库存,您可以联系我们找货

免费人工找货
AQW454AX
    •  国内价格 香港价格
    • 1+92.798711+11.21400
    • 10+72.1685010+8.72100
    • 50+62.9333150+7.60500
    • 100+52.58097100+6.35400
    • 500+49.00606500+5.92200
    • 1000+47.963381000+5.79600
    • 2000+46.920702000+5.67000
    • 4000+46.399364000+5.60700

    库存:75