0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AQY222R2VY

AQY222R2VY

  • 厂商:

    NAIS(松下)

  • 封装:

    SMD4

  • 描述:

    RELAYOPTO60V0.4ASSOP

  • 数据手册
  • 价格&库存
AQY222R2VY 数据手册
Automation Controls Catalog C✕R type, SSOP package, 60 V, 80 V and 100 V load voltage RF SSOP 1 Form A C×R (AQY22❍❍❍V) FEATURES New 4.45 .175 2.65 .104 1.80 .071 mm inch 1 4 2 3 RoHS compliant 1. Miniature SSOP package (Compared to SOP 4-pin models, volume ratio can be reduced by approximately 53%.) 2. Load voltage: 60 V, 80 V and 100 V 3. Low C×R Low on resistance and low output capacitance available • 60 V load voltage Output capacitance: 27 pF (typical), On resistance: 0.8Ω (typical) • 80 V load voltage Output capacitance: 4.5 pF (typical), On resistance: 10.5Ω (typical) • 100 V load voltage Output capacitance: 5.8 pF (typical), On resistance: 8.8Ω (typical) 4. Turn on time 80 V and 100 V load voltage type: 0.05 ms (typical) TYPICAL APPLICATIONS 1. Measuring and testing equipment Semiconductor testing equipment, Probe cards, Datalogger, Board tester and other testing equipment 2. Telecommunication and broadcasting equipment 3. Medical equipment Ultrasonic wave diagnostic machine 4. Multi-point recorder Warping, Thermo couple, etc. *Does not support automotive applications. TYPES Type Output rating*1 Load voltage Load current New 60 V AC/DC dual use 400 mA Part No. (Tape and reel packing style)*2 Picked from the 1 and 4-pin side Picked from the 2 and 3-pin side AQY222R2VY Packing quantity in the tape and reel AQY222R2VW 80 V 120 mA AQY225R2VY AQY225R2VW New 100 V 120 mA AQY225R3VY AQY225R3VW 3,500 pcs. Notes: *1. Indicate the peak AC and DC values. *2. Only tape and reel package is available. Packing quantity of 1,000 pieces is possible. Please consult us. For space reasons, the three initial letters of the part number “AQY”, the package (SSOP) indication “V”, and the packaging style “Y” or “W” are not marked on the device. 2014.03 industrial.panasonic.com/ac/e/ –1– –1– © Panasonic Corporation 2014 ASCTB34E 201403-T RF SSOP 1 Form A C×R (AQY22❍❍❍V) RATING 1. Absolute maximum ratings (Ambient temperature: 25°C 77°F) Item LED forward current LED reverse voltage Input side Peak forward current Power dissipation Load voltage (peak AC) Continuous load current Output side Peak load current Power dissipation Total power dissipation I/O isolation voltage Operating temperature Storage temperature Symbol IF VR IFP Pin VL IL Ipeak Pout PT Viso Topr Tstg AQY222R2V AQY225R2V 50 mA 5V 1A 75 mW 80 V 60 V 0.4 A 1.2 A AQY225R3V Remarks f = 100 Hz, Duty factor = 0.1% 100 V 0.12 A 0.3 A Peak AC, DC 100 ms (1shot), VL = DC 250 mW 300 mW 1,500 V AC –40°C to +85°C –40°F to +185°F –40°C to +100°C –40°F to +212°F Non-condensing at low temperatures 2. Electrical characteristics (Ambient temperature: 25°C 77°F) Item LED operate current Input LED turn off current LED dropout voltage Symbol Typical Maximum Minimum Typical Typical Maximum AQY222R2V IFon IFoff VF Typical 0.8Ω Output capacitance Off state leakage current Turn on time** Transfer characteristics Turn off time** I/O capacitance Initial I/O isolation resistance 10.5Ω 8.8Ω Ron On resistance Output AQY225R2V AQY225R3V 0.5 mA 3.0 mA 0.1 mA 0.45 mA 1.32 V (1.14 V at IF = 5 mA) 1.5 V Maximum 1.25Ω 15Ω 14Ω Typical Maximum Typical Maximum Typical Maximum Typical Maximum Typical Maximum 27 pF 40 pF — 4.5 pF 6 pF 5.8 pF 8 pF Minimum Cout ILeak 0.01 nA 10 nA* 0.15 ms Ton AQY222R2V: IL = 400 mA AQY225R2V: IL = 80 mA AQY225R3V: IL = 80 mA IF = 50 mA AQY222R2V: IF = 5 mA, IL = 400 mA AQY225R2V: IF = 5 mA, IL = 80 mA AQY225R3V: IF = 5 mA, IL = 80 mA Within 1 s on time IF = 0 mA, VB = 0 V, f = 1 MHz IF = 0 mA, VL = Max. 0.05 ms 0.5 ms 0.08 ms Toff Condition 0.05 ms 0.2 ms 0.8 pF 1.5 pF Ciso Riso AQY222R2V: IF = 5 mA, VL = 10 V, RL = 100Ω AQY225R2V: IF = 5 mA, VL = 10 V, RL = 125Ω AQY225R3V: IF = 5 mA, VL = 10 V, RL = 125Ω f = 1 MHz, VB = 0 V 1,000 MΩ 500 V DC Notes: 1. Please refer to the “Schematic and Wiring Diagrams” for connection method. 2. Variation possible through combinations of output capacitance and on resistance. For more information, please contact our sales office in your area. *Available as custom orders (1 nA or less) **Turn on/Turn off time Input 90% 10% Output Toff Ton RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper this device operation and resetting. Item Input LED forward current Symbol IF Recommended value 5 Unit mA ■ For Dimensions, see Page 5. ■ For Schematic and Wiring Diagrams, see Page 5. ■ These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –2– © Panasonic Corporation 2014 ASCTB34E 201403-T RF SSOP 1 Form A C×R (AQY22❍❍❍V) REFERENCE DATA 1.-(1) Load current vs. ambient temperature characteristics 1.-(2) Load current vs. ambient temperature characteristics 2.-(1) On resistance vs. ambient temperature characteristics Allowable ambient temperature: –40°C to +85°C –40°F to +185°F Allowable ambient temperature: –40°C to +85°C –40°F to +185°F Measured portion: between terminals 3 and 4 LED current: 5 mA; Load voltage: 10V (DC) Continuous load current: Max. (DC) 120 AQY222R2V Load current, mA 0.4 Load current, A 2 140 0.3 0.2 AQY225R2V, AQY225R3V On resistance, Ω 0.5 100 80 60 40 1.5 1 AQY222R2V 0.5 0.1 20 0 -40 -20 0 20 40 60 0 -40 80 85 100 -20 0 20 40 60 0 80 85 100 -40 -20 0 20 40 60 80 85 Ambient temperature, °C Ambient temperature, °C Ambient temperature, °C 3.-(1) Turn on time vs. ambient temperature characteristics 3.-(2) Turn on time vs. ambient temperature characteristics Measured portion: between terminals 3 and 4; LED current: 5 mA; Load voltage: 10V (DC); Continuous load current: 80mA (DC) LED current: 5 mA; Load voltage: 10V (DC); Continuous load current: 100mA (DC) LED current: 5 mA; Load voltage: 10V (DC); Continuous load current: 80mA (DC) 0.5 0.2 40 0.4 0.16 30 20 Turn on time, ms 50 Turn on time, ms On resistance, Ω 2.-(2) On resistance vs. ambient temperature characteristics 0.3 0.2 0.12 0.08 AQY225R2V AQY225R3V AQY222R2V AQY225R2V 10 0.1 0.04 AQY225R3V 0 -40 -20 0 20 40 60 0 80 85 -40 -20 0 20 40 60 0 80 85 -40 -20 Ambient temperature, °C Ambient temperature, °C 0 20 40 60 80 85 Ambient temperature, °C 4.-(2) Turn off time vs. ambient temperature characteristics 5.-(1) LED operate current vs. ambient temperature characteristics LED current: 5 mA; Load voltage: 10V (DC); Continuous load current: 100mA (DC) LED current: 5 mA; Load voltage: 10V (DC); Continuous load current: 80mA (DC) Load voltage: 10V (DC); Continuous load current: 400mA (DC) 0.2 0.4 0.16 0.3 0.2 3 0.12 0.08 AQY225R3V AQY222R2V 0.1 0 0.04 -40 -20 0 20 40 60 Ambient temperature, °C 80 85 0 2.5 2 1.5 1 AQY225R2V AQY222R2V 0.5 -40 -20 0 20 40 60 Ambient temperature, °C Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ LED operate current, mA 0.5 Turn off time, ms Turn off time, ms 4.-(1) Turn off time vs. ambient temperature characteristics –3– 80 85 0 -40 -20 0 20 40 60 80 85 Ambient temperature, °C © Panasonic Corporation 2014 ASCTB34E 201403-T RF SSOP 1 Form A C×R (AQY22❍❍❍V) 5.-(2) LED operate current vs. ambient temperature characteristics 6.-(1) LED turn off current vs. ambient temperature characteristics 6.-(2) LED turn off current vs. ambient temperature characteristics Load voltage: 10V (DC); Continuous load current: 80mA (DC) Load voltage: 10V (DC); Continuous load current: 400mA (DC) Load voltage: 10V (DC); Continuous load current: 80mA (DC) 4 3 2 1 AQY225R2V 2.5 2 1.5 1 -40 -20 AQY222R2V 0.5 AQY225R3V 0 5 LED turn off current, mA 3 LED turn off current, mA LED operate current, mA 5 0 20 40 60 0 80 85 -40 -20 Ambient temperature, °C 0 20 4 3 2 1 40 60 0 80 85 AQY225R2V AQY225R3V -40 -20 Ambient temperature, °C 0 20 40 60 80 85 Ambient temperature, °C 7. LED dropout voltage vs. ambient temperature characteristics 8.-(1) Current vs. voltage characteristics of output at MOS portion 8.-(2) Current vs. voltage characteristics of output at MOS portion LED current: 5 to 50 mA Measured portion: between terminals 3 and 4; Ambient temperature: 25°C 77°F Measured portion: between terminals 3 and 4; Ambient temperature: 25°C 77°F 250 1.4 Current, mA 1.5 Current, A LED dropout voltage, V 1.5 1.0 AQY222R2V 0.5 200 100 AQY225R2V 50 1.3 0.5 1.0 1.5 2.0 -50 Voltage, V 0.1 0.2 0.3 0.4 0.5 Voltage, V 30mA 20mA 1.1 -2.0 -1.5 -1.0 -0.5 -0.5 -0.4 -0.3 -0.2 -0.1 50mA 1.2 -0.5 10mA -100 -150 -1.0 -200 5mA 1.0 AQY225R3V 150 -40 -20 0 20 40 60 -250 -1.5 80 85 100 Ambient temperature, °C 9.-(1) Off state leakage current vs. load voltage characteristics 9.-(2) Off state leakage current vs. load voltage characteristics 10.-(1) Turn on time vs. LED forward current characteristics Measured portion: between terminals 3 and 4; Ambient temperature: 25°C 77°F Measured portion: between terminals 3 and 4; Ambient temperature: 25°C 77°F Measured portion: between terminals 3 and 4; Load voltage: 10V (DC); Continuous load current: 100mA (DC); Ambient temperature: 25°C 77°F 0.5 10-6 10-9 AQY222R2V Turn on time, ms 10-3 Leakage current, A Leakage current, A 10-3 10-6 10-9 0.4 0.3 0.2 AQY225R2V AQY222R2V 0.1 10 -12 0 10 20 40 60 80 -12 AQY225R3V 0 100 20 40 60 80 0 0 100 10 Load voltage, V Load voltage, V 20 30 40 50 60 LED forward current, mA 10.-(2) Turn on time vs. LED forward current characteristics 11.-(1) Turn off time vs. LED forward current characteristics 11.-(2) Turn off time vs. LED forward current characteristics Measured portion: between terminals 3 and 4; Load voltage: 10V (DC); Continuous load current: 80mA (DC); Ambient temperature: 25°C 77°F Measured portion: between terminals 3 and 4; Load voltage: 10V (DC); Continuous load current: 100mA (DC); Ambient temperature: 25°C 77°F Measured portion: between terminals 3 and 4; Load voltage: 10V (DC); Continuous load current: 80mA (DC); Ambient temperature: 25°C 77°F 0.5 0.15 0.1 0.05 0.2 0.4 Turn off time, ms Turn off time, ms Turn on time, ms 0.2 0.3 0.2 AQY225R2V AQY225R3V AQY222R2V 0.15 0.1 AQY225R2V AQY225R3V 0.05 0.1 0 0 10 20 30 40 50 0 0 LED forward current, mA 10 20 Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ 30 40 50 60 0 0 10 –4– 20 30 40 50 60 LED forward current, mA LED forward current, mA © Panasonic Corporation 2014 ASCTB34E 201403-T RF SSOP 1 Form A C×R (AQY22❍❍❍V) 12.-(1) Output capacitance vs. applied voltage characteristics 12.-(2) Output capacitance vs. applied voltage characteristics Measured portion: between terminals 3 and 4; Measurement signal: 1 MHz; Ambient temperature: 25°C 77°F Measured portion: between terminals 3 and 4; Measurement signal: 1 MHz (30m Vrms); Ambient temperature: 25°C 77°F 10 Output capacitance, pF Output capacitance, pF 50 40 30 20 AQY222R2V 10 8 6 4 AQY225R2V 2 AQY225R3V 0 0 20 40 60 80 0 0 100 20 40 Applied voltage, V DIMENSIONS (mm inch) 60 80 100 Applied voltage, V The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions Recommended mounting pad (Top view) 4.45 .175 0.90 .035 0.70 .028 2.65 .104 1.27 .050 4.35 .171 Tolerance: ±0.1 ±.004 CAD Data 1.80 .071 0.20 .008 (4.85) (4.85) 0.20 0.40 .008 .016 0.40 .016 1.27 .050 Terminal thickness = 0.15 .006 General tolerance: ±0.1 ±.004 SCHEMATIC AND WIRING DIAGRAMS E1: Power source at input side; IF: LED forward current; VL: Load voltage; IL: Load current Output configuration Schematic 1 Connection Wiring diagram 4 1a 2 Load AC/DC — E1 1 4 2 3 IF 3 4 IL VL (AC,DC) Load IL VL (AC,DC) 3 Load Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –5– © Panasonic Corporation 2014 ASCTB34E 201403-T
AQY222R2VY 价格&库存

很抱歉,暂时无法提供与“AQY222R2VY”相匹配的价格&库存,您可以联系我们找货

免费人工找货