ARXP1212

ARXP1212

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
ARXP1212 数据手册
MicrowaveDevices.book Page 53 Wednesday, November 26, 2008 7:50 PM RX (ARX) 3 GHz SMALL MICROWAVE RELAY RX RELAYS (ARX) FEATURES 1. Excellent high frequency characteristics (~2.5GHz, Impedance 50Ω) Frequency V.S.W.R. (Max.) Insertion loss (dB, Max.) Isolation (dB, Min.) to 2.5GHz 1.2 0.2 60 2. Small size • Size: 20.5(L) × 12.4(W) × 9.4(H) mm .807(L) × .488(W) × .370(H) inch 3. High sensitivity • Nominal operating power: 200 mW 4. Infrequent switching type is also available. Please inquire. 0 TYPICAL APPLICATIONS Insertion loss, dB COM-NC 0.1 • Cellular phone base station • Cellular phone-related measurement devices (SP3T/SP4T switches, etc) • Wireless LAN • Wireless Local Loop 0.2 COM-NO 0.3 0.4 0.5 300kHz Compliance with RoHS Directive 1.5GHz 2.5GHz3GHz If you wish to use in applications with low level loads or with high frequency switching, please consult us. Frequency ORDERING INFORMATION ARX 1 RX relays Contact arrangement 1: 1 Form C Operating function 0: Single side stable 1: 1 coil latching 2: 2 coil latching Coil voltage (DC) 03: 3V, 4H: 4.5V, 06: 6V, 09: 9V, 12: 12V, 24: 24V (H=0.5) TYPES Nominal coil voltage 3 V DC 4.5V DC 6 V DC 9 V DC 12 V DC 24 V DC Single side stable ARX1003 ARX104H ARX1006 ARX1009 ARX1012 ARX1024 Part No. 1 coil latching ARX1103 ARX114H ARX1106 ARX1109 ARX1112 ARX1124 Standard packing: 50 pcs. in an inner package; 500 pcs. in an outer package All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 2 coil latching ARX1203 ARX124H ARX1206 ARX1209 ARX1212 ARX1224 MicrowaveDevices.book Page 54 Wednesday, November 26, 2008 7:50 PM RX (ARX) RATING 1. Coil data 1) Single side stable Nominal coil voltage 3 V DC 4.5V DC 6 V DC 9 V DC 12 V DC 24 V DC Pick-up voltage (at 20°C 68°F) 75%V or less of nominal voltage (Initial) Drop-out voltage (at 20°C 68°F) 10%V or more of nominal voltage (Initial) Nominal operating current [±10%] (at 20°C 68°F) 66.7mA 44.4mA 33.3mA 22.2mA 16.7mA 8.3mA Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 60°C 140°F) 200mW 110%V of nominal voltage Nominal operating power Max. applied voltage (at 60°C 140°F) 200mW 110%V of nominal voltage Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 60°C 140°F) 22.5Ω 50.6Ω 90 Ω 202.5Ω 360 Ω 1,440 Ω 400mW 110%V of nominal voltage 45 101 180 405 720 2,880 Ω Ω Ω Ω Ω Ω 2) 1 coil latching type Nominal coil voltage 3 V DC 4.5V DC 6 V DC 9 V DC 12 V DC 24 V DC Set voltage (at 20°C 68°F) 75%V or less of nominal voltage (Initial) Reset voltage (at 20°C 68°F) 75%V or less of nominal voltage (Initial) Nominal operating current [±10%] (at 20°C 68°F) 66.7mA 44.4mA 33.3mA 22.2mA 16.7mA 8.3mA Coil resistance [±10%] (at 20°C 68°F) 45 101 180 405 720 2,880 Ω Ω Ω Ω Ω Ω 3) 2 coil latching type Nominal coil voltage 3 V DC 4.5V DC 6 V DC 9 V DC 12 V DC 24 V DC Set voltage (at 20°C 68°F) 75%V or less of nominal voltage (Initial) Reset voltage (at 20°C 68°F) 75%V or less of nominal voltage (Initial) Nominal operating current [±10%] (at 20°C 68°F) 133.3mA 88.9mA 66.7mA 44.4mA 33.3mA 16.7mA 2. Specifications Characteristics Contact Rating High frequency characteristics (Initial) (~2.5GHz, Impedance 50Ω) Item Arrangement Contact material Initial contact resistance, max. Contact rating Contact carrying power Max. switching voltage Max. switching current Single side stable Nominal operating 1 coil latching power 2 coil latching V.S.W.R. (Return loss) Insertion loss Isolation Input power Insulation resistance (Initial) Electrical characteristics Breakdown voltage (Initial) Between open contacts Between contact and coil Between contact and earth terminal Temperature rise (at 20°C) Operate time [Set time] (at 20°C) Release time [Reset time] (at 20°C) Mechanical characteristics Shock resistance Vibration resistance Functional Destructive Functional Destructive Mechanical Expected life Conditions Unit weight Electrical Conditions for operation, transport and storage* Specifications 1 Form C Stationary: Gold plating, Movable: Gold clad Max. 100mΩ (By voltage drop 10V AC 10mA) 10W (2.5GHz, Impedance 50Ω, V.S.W.R. 1.2) 10mA 24V DC (resistive load) Max. 20W (at 2.5GHz, Impedance 50Ω, V.S.W.R. 1.2, Average) 30V DC 0.5A DC 200mW 200mW 400mW Max. 1.2 (Min. 20.8dB) Max. 0.2dB Min. 60dB Max. 20W (at 40°C, V.S.W.R. 1.2, Average) Min. 100MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. 500 Vrms for 1min. (Detection current: 10mA) 1,000 Vrms for 1min. (Detection current: 10mA) 500 Vrms for 1min. (Detection current: 10mA) Max. 60°C (By resistive method, nominal voltage applied to the coil: Contact carrying power: 20W, at 2.5GHz, Impedance 50Ω, V.S.W.R. 1.2) Max. 10ms (Approx. 6ms) [Max. 10ms (Approx. 5ms)] (Nominal operating voltage applied to the coil, excluding contact bounce time.) Max. 6ms (Approx. 3ms) [Max. 10ms (Approx. 5ms)] (Nominal operating voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 200 m/s2 {20 G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs.) Min. 1,000m/s2 {100 G} (Half-wave pulse of sine wave: 6ms.) 10 to 55 Hz at double amplitude of 3mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 5mm Min. 5×106 (at 180 cpm) Min. 105 (10W 2.5 GHz, Impedance 50Ω, V.S.W.R. 1.2) Min. 3×105 (10mA 24V DC resistive load) Ambient temperature: –40°C to +70°C –40°F to +158°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 5 g .18 oz Note: * The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT in GENERAL APPLICATION GUIDELINES. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. MicrowaveDevices.book Page 55 Wednesday, November 26, 2008 7:50 PM RX (ARX) REFERENCE DATA 1. High frequency characteristics Sample: ARX1012 Measuring method: Measured with HP network analyzer (HP8753C). The details for the high frequency characteristics and the measurement procedures and conditions are listed in the RX relay test report. • V.S.W.R. (Return loss) • Insertion loss • Isolation 0 0 0 COM-NO 20 1.2 1.1 30 0.1 20 Isolation, dB 1.5 Insertion loss, dB COM-NC 2.0 10 V.S.W.R. Return loss, dB 5.0 0.2 COM-NO 40 COM-NC 0.3 60 0.4 80 COM-NC 40 0.5 300kHz 50 1.5GHz 2.5GHz 3GHz 1.5GHz 100 300kHz 2.5GHz3GHz 1.5GHz Frequency Frequency Frequency DIMENSIONS (mm inch) The CAD data of the products with a CAD Data 2.5GHz 3GHz mark can be downloaded from: http://panasonic-electric-works.net/ac PC board pattern (Bottom view) CAD Data 20.5 .807 12.4 .488 0.9 dia hole .035 dia hole 7.62 .300 0.2 .008 2.63 .104 (2 coil latching type only) 2.54 .100 9.2 .362 2.54 .100 3.0 .118 7.62 .300 (2.04) (.080) R (2.74) (.108) 0.90 .035 0. 45 2-0.6×0.3 2-.024×.012 Tolerance: ±0.1 ±.004 General tolerance: ±0.3 ±.012 Solder to the PC board earth. Schematic (Bottom view) 7-0.40 to 0.45 dia. 7-.016 to .018 dia. 1 7 14 13 12 11 10 9 NC COM 8 NO (Deenergized condition) 1 coil latching Direction indication Direction indication Single side stable 1 7 14 13 12 11 10 9 RESET 2 coil latching COM 8 SET (Reset condition) All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Direction indication 300kHz COM-NO 6 7 14 13 12 11 10 9 8 1 RESET COM SET (Reset condition) MicrowaveDevices.book Page 56 Wednesday, November 26, 2008 7:50 PM RX (ARX) NOTES 6. Conditions for operation, transport and storage conditions 1) Ambient temperature, humidity, and atmospheric pressure during usage, transport, and storage of the relay: (1) Temperature: –40 to +70°C –40 to +158°F (2) Humidity: 5 to 85% RH (Avoid freezing and condensation.) The humidity range varies with the temperature. Use within the range indicated in the graph below. (3) Atmospheric pressure: 86 to 106 kPa Temperature and humidity range for usage, transport, and storage: Humidity, %RH ;;;;;;;;; ;;;;;;;;;; ;;;;;;;;;; ;;;;;;;;;; ;;;;;;;;;; ;;;;;;;;;; ;;;;;;;;;; 1. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular. lf it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. The nominal operating voltage should be applied to the coil for more than 30 ms to set/reset the latching type relay. 2. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or malfunction. 3. External magnetic field Since RX relays are highly sensitive polarized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition. 4. Cleaning For automatic cleaning, the boiling method is recommended. Avoid ultrasonic cleaning which subjects the relays to high frequency vibrations, which may cause the contacts to stick. lt is recommended that a fluorinated hydrocarbon or other alcoholic solvents be used. 5. Soldering The manual soldering shall be performed under following condition. Max. 260°C 500°F 10s Max. 350°C 662°F 3s In addition, when soldering the case to the PC board, the plating may swell depending on the soldering conditions. 4) Low temperature, low humidity environments The plastic becomes brittle if the relay is exposed to a low temperature, low humidity environment for long periods of time. 7. Latching relay In order to assure proper operating regardless of changes in the ambient usage temperature and usage conditions, nominal operating voltage should be applied to the coil for more than 30 ms to set/reset the latching type relay. For general cautions for use, please refer to the “General Application Guidelines”. 85 Tolerance range (Avoid freezing when used at temperatures lower than 0°C 32°F 5 –40 –40 (Avoid condensation when used at temperatures higher than 0°C 32°F 0 +32 Temperature, °C °F 70 +158 2) Condensation Condensation forms when there is a sudden change in temperature under high temperature and high humidity conditions. Condensation will cause deterioration of the relay insulation. 3) Freezing Condensation or other moisture may freeze on the relay when the temperature is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
ARXP1212 价格&库存

很抱歉,暂时无法提供与“ARXP1212”相匹配的价格&库存,您可以联系我们找货

免费人工找货
ARXP1212

库存:0