0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ASEN60512

ASEN60512

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    ACFANMOTOR

  • 数据手册
  • 价格&库存
ASEN60512 数据手册
Fan Motor Selector Chart AC FAN MOTOR ASEN6051∗ 60 sq.×30t ASEN8021∗ NEW 80 sq.×25t NEW ASEN804∗∗∗ 80 sq.×38t NEW Type Rated voltage Frequency Input power (W) +10 −20% Rated current, max. (mA) Locked current (mA) Rotation speed, min. (r/min) Max. air flow, min. (m3/min) Max. static pressure, min. (Pa) Noise, average (dB(A)) Operating voltage range (V) Weight (kg) Page 100 V 115 V 100 V 50/60 Hz 6/5 80/70 85/75 115 V 50/60 Hz 4.5/4 70/60 70/60 6/5 90/80 95/85 2,000/2,600 0.2/0.26 13.7/22.6 28/29 Rated voltage ±10% 0.14 14 ASEN902∗∗∗ 6/5 80/70 85/75 2,400/2,750 0.74/0.85 37.5/43 28/33 Rated voltage ±10% 0.22 15 92 sq.×25t 100 V 115 V 200 V 50/60 Hz 9/7 170/120 140/110 80/65 180/160 160/140 90/80 2,700/3,200 0.75/0.9 44.2/62.8 33/38 Rated voltage ±10% 0.3 16 ASEN102∗∗∗ NEW 230 V 10/8 70/55 80/70 120 sq.×25t NEW Type Rated voltage Frequency Input power (W) +10 −20% Rated current, max. (mA) Locked current (mA) Rotation speed, min. (r/min) Max. air flow, min. (m3/min) Max. static pressure, min. (Pa) Noise, average (dB(A)) Operating voltage range (V) Weight (kg) Page 100 V 190/150 200/170 115 V 200 V 50/60 Hz 13/10 170/130 100/80 180/160 110/100 2,600/3,100 0.80/0.98 43.1/60.8 34/39 Rated voltage ±10% 0.3 17 ASEN104∗∗∗ 230 V 100 V 90/70 100/80 220/180 220/200 120 sq.×38t 115 V 200 V 50/60 Hz 14/11 190/160 110/90 200/180 120/100 2,300/2,700 1.8/2.0 41.2/41.2 34/38 Rated voltage ±10% 0.36 18 ASEN5075∗ NEW 230 V 100/90 110/100 150×172×38t NEW Type Rated voltage Frequency Input power (W) +10 −20% Rated current, max. (mA) Locked current (mA) Rotation speed, min. (r/min) Max. air flow, min. (m3/min) Max. static pressure, min. (Pa) Noise, average (dB(A)) Operating voltage range (V) Weight (kg) Page 100 V 15/14 270/230 370/300 115 V 200 V 50/60 Hz 15.5/14.5 15/13 250/210 140/120 320/270 190/170 2,600/2,900 2.5/2.9 64.7/76.4 37/41 Rated voltage ±10% 0.55 19 02/2006 230 V 100 V 115 V 200 V 230 V 50/60 Hz 15/14 120/100 160/140 37/33 470/400 750/700 35/32 34/33 380/360 230/210 550/530 340/320 2,700/3,200 5.0/6.0 157/215.8 52/56 Rated voltage ±10% 0.8 20 35/35 190/180 280/310 1 Product Types AC FAN MOTOR Size Specifications Rotation speed 60 sq.×30 Lead wire type Standard speed 80 sq.×25 Lead wire type Standard speed Lead wire type Standard speed 2-terminal type Standard speed Lead wire type Standard speed 2-terminal type Standard speed Lead wire type Standard speed 2-terminal type Standard speed Lead wire type Standard speed 2-terminal type Standard speed 2-terminal type Standard speed 80 sq.×38 92 sq.×25 120 sq.×25 120 sq.×38 150×172×38 Voltage 100V AC 115V AC 100V AC 115V AC 100V AC 115V AC 200V AC 230V AC 100V AC 115V AC 200V AC 230V AC 100V AC 115V AC 200V AC 230V AC 100V AC 115V AC 200V AC 230V AC 100V AC 115V AC 200V AC 230V AC 100V AC 115V AC 200V AC 230V AC 100V AC 115V AC 200V AC 230V AC 100V AC 115V AC 200V AC 230V AC 100V AC 115V AC 200V AC 230V AC Part number ASEN60511 ASEN60512 ASEN80211 ASEN80212 ASEN80411 ASEN80412 ASEN80414 ASEN80416 ASEN804519 ASEN804529 ASEN804549 ASEN804569 ASEN90211 ASEN90212 ASEN90214 ASEN90216 ASEN902519 ASEN902529 ASEN902549 ASEN902569 ASEN10211 ASEN10212 ASEN10214 ASEN10216 ASEN102519 ASEN102529 ASEN102549 ASEN102569 ASEN10411 ASEN10412 ASEN10414 ASEN10416 ASEN104519 ASEN104529 ASEN104549 ASEN104569 ASEN50751 ASEN50752 ASEN50754 ASEN50756 Notes: 1. Although “standard speed” is used as the standard fan rotation speed, middle speed and low speed types can be special ordered. 2. 220 V AC and 240 V AC types can be special ordered. ACCESSORIES 1. Plug Cord for AC Fan Motor Product name Plug code for 2-terminal type Specifications For inside of appliance, L = 1,000 mm Compliant with Electrical Appliance and Material Safety Law, L = 1,000 mm UL Standard, L = 1,000 mm Part number ASE51100 ASE51107 ASE51109 2. Fan Guard for DC and AC Fan Motor Product name 40 sq. 60 sq. 80 sq. 92 sq. 80 sq. 92 sq. 120 sq. 150×172 Specifications Recognized by UL/CSA Recognized by UL/CSA Recognized by UL/CSA Recognized by UL/CSA Compliant with Electrical Appliance and Material Safety Law Compliant with Electrical Appliance and Material Safety Law Compliant with Electrical Appliance and Material Safety Law Recognized by UL/CSA Part number ASFN48001 ASFN68001 ASFN88001 ASFN98001 ASEN88001 ASEN98001 ASEN18001 ASEN58001 3. Filter for DC and AC Fan Motor Product name 60 sq. 80 sq. 92 sq. 120 sq. Part number ASEN68002 ASEN88002 ASEN98002 ASEN18002 02/2006 2 Ordering Information AC Type ASEN 1 0 2 5 1 9 Size 1: 120 sq. 5: 150 x 172 6: 60 sq. 8: 80 sq. 9: 92 sq. Speed 0: Standard 2: Middle 4: Low Case thickness 2: 25t 4: 38t 5: 30t 7: 38t (150 x 172 only) Input type 1: Lead wire type 5: 2-terminal type Rated voltage 1: 100 V AC 2: 115 V AC 4: 200 V AC 5: 220 V AC 6: 230 V AC 7: 240 V AC Terminal specification 9: Terminal specification only (150 x 172 type not applicable) • For the AC type, a middle speed type, low speed type, and 220 V and 240V types can be special ordered. *Depending on the combination, not all specifications can be met. For details, please consult us. 02/2006 3 60 sq.×30t (ASEN6) AC Fan Motor DIMENSIONS (mm inch) NEW 300 min 11.811 min Airflow 8- 8-4 .1 .3 69 d diaia. . 60±0.5 50±0.3 2.362±.020 1.969±.012 3.5 .138 RoHS Directive compatibility information http://www.nais-e.com/ 3.5 .138 30±0.5 1.181±.020 50±0.3 1.969±.012 60±0.5 2.362±.020 RATING Lead wire type, Standard speed Part number ASEN60511 ASEN60512 Rated voltage (V) 100 115 Frequency (Hz) 50/60 Input power, +10 −20 % (W) 6/5 4.5/4 Rated current, max. (mA) 80/70 70/60 Locked current, max. (mA) 85/75 70/60 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2000/2600 0.2/0.26 13.7/22.6 28/29 (29/30) ±10 0.14 Notes: 1. Asterisks in the table above indicate minimum values. 2. Values above without designations are averages. 3. Noise level was measured at a distance of 1 m from side of fan. Values in brackets were measured at a distance of 1 m from front of fan. DATA (Airflow - Static pressure Characteristic Curve) 30 Static pressure (Pa) 60 Hz 50 Hz Frame: aluminum alloy die-casting Propeller: plastic Bearings: ball bearings Lead wires: UL3266 and AWG22 Label: 100 V class...black base SPECIFICATIONS 20 10 0 MATERIALS USED 0.2 0.3 0.1 Airflow (m3/min) Ambient temperature Ambient humidity Storage temperature Breakdown voltage Insulation resistance Insulation class Frequency Double amplitude width Vibration resistance Applied direction Applied time Protection Mean life –10°C to +60°C +14°F to +140°F 15 to 85%RH –20°C to +70°C –4°F to +158°F 1,500 V AC for 1 min. (between charging section and frame) Min. 100MΩ (at 500 V DC megger)(between charging section and frame) UL:A class, CSA:B class 10 to 55Hz 0.75mm X, Y and Z directions 10 min. in each direction Impedance protected MTTF: 50,000 hrs. (Time it takes until rotation frequency drops 30% of initial value when run continuously under 25°C 77°F and room humidity at the nominal voltage.) 02/2006 4 80 sq.×25t (ASEN8) AC Fan Motor DIMENSIONS (mm inch) NEW 300 min 11.811 min a. di ia. 3 d 4. 9 8- -.16 8 Airflow 71.5±0.3 80±0.5 2.815±.012 3.150±.020 71.5±0.3 2.815±.012 80±0.5 3.150±.020 25±0.5 .984±.020 RoHS Directive compatibility information http://www.nais-e.com/ RATING Lead wire type, Standard speed Part number ASEN80211 ASEN80212 Rated voltage (V) 100 115 Frequency (Hz) Input power, +10 −20 % (W) 50/60 6/5 Rated current, max. (mA) 90/80 80/70 Locked current, max. (mA) 95/85 85/75 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2400/2750 0.74/0.85 37.5/43 28/33 (29/34) ±10 0.22 Notes: 1. Asterisks in the table above indicate minimum values. 2. Values above without designations are averages. 3. Noise level was measured at a distance of 1 m from side of fan. Values in brackets were measured at a distance of 1 m from front of fan. DATA (Airflow - Static pressure MATERIALS USED Characteristic Curve) Frame: aluminum alloy die-casting Propeller: plastic Bearings: ball bearings Lead wires: UL3266 and AWG22 60 Static pressure (Pa) 60Hz 50Hz Label: 100 V class...black base SPECIFICATIONS 40 20 0 0.2 0.4 0.6 0.8 Airflow (m3/min) 1.0 Ambient temperature Ambient humidity Storage temperature Breakdown voltage Insulation resistance Insulation class Frequency Double amplitude width Vibration resistance Applied direction Applied time Protection Mean life 02/2006 –10°C to +60°C +14°F to +140°F 15 to 85%RH –20°C to +70°C –4°F to +158°F 1,500 V AC for 1 min. (between charging section and frame) Min. 100MΩ (at 500 V DC megger)(between charging section and frame) UL:A class, CSA:B class 10 to 55Hz 0.75mm X, Y and Z directions 10 min. in each direction Impedance protected MTTF: 50,000 hrs. (Time it takes until rotation frequency drops 30% of initial value when run continuously under 25°C 77°F and room humidity at the nominal voltage.) 5 80 sq.×38t (ASEN8) AC Fan Motor DIMENSIONS (mm inch) NEW Earth tap M4 (200V class) 300 min 11.811 min Airflow 300 min 11.811 min Airflow 8- 8-4 .1 .3 69 di dia a. . 71.5±0.2 2.815±.008 80±0.5 3.150±.020 RoHS Directive compatibility information http://www.nais-e.com/ 3.4 .134 RATING 3.4 .134 38+0.8 0 3.4 .134 3.4 .134 38+0.8 0 71.5±0.2 2.815±.008 80±0.5 3.150±.020 1.496 +.031 0 1.496 +.031 0 Lead wire type 2 terminals type 1. Lead wire type, Standard speed Part number ASEN80411 ASEN80412 ASEN80414 ASEN80416 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 9/7 50/60 10/8 Rated current, max. (mA) 170/120 140/110 80/65 70/55 Locked current, max. (mA) 180/160 160/140 90/80 80/70 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2700/3200 0.75/0.9 44.2/62.8 33/38 (36/42) ±10 0.3 Rated current, max. (mA) 170/120 140/110 80/65 70/55 Locked current, max. (mA) 180/160 160/140 90/80 80/70 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2700/3200 0.75/0.9 44.2/62.8 33/38 (36/42) ±10 0.3 2. 2 terminals type, Standard speed Part number ASEN804519 ASEN804529 ASEN804549 ASEN804569 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 9/7 50/60 10/8 Notes: 1. Asterisks in the table above indicate minimum values. 2. Values above without designations are averages. 3. Noise level was measured at a distance of 1 m from side of fan. Values in brackets were measured at a distance of 1 m from front of fan. DATA (Airflow - Static pressure MATERIALS USED Characteristic Curve) Static pressure (Pa) 60 Hz 50 Hz Frame: aluminum alloy die-casting Propeller: plastic Bearings: ball bearings Lead wires: UL3266 and AWG22 Terminal: Equivalent to Faston #110 Label: 100 V class...black base 200 V class...red base 60 SPECIFICATIONS 40 20 0 0.2 0.4 0.6 0.8 Airflow (m3/min) 1.0 Ambient temperature Ambient humidity Storage temperature Breakdown voltage Insulation resistance Insulation class Frequency Double amplitude width Vibration resistance Applied direction Applied time Protection Mean life –10°C to +60°C +14°F to +140°F 15 to 85%RH –20°C to +70°C –4°F to +158°F 1,500 V AC for 1 min. (between charging section and frame) Min. 100MΩ (at 500 V DC megger)(between charging section and frame) UL:A class, CSA:B class 10 to 55Hz 0.75mm X, Y and Z directions 10 min. in each direction Impedance protected MTTF: 50,000 hrs. (Time it takes until rotation frequency drops 30% of initial value when run continuously under 25°C 77°F and room humidity at the nominal voltage.) 02/2006 6 92 sq.×25t (ASEN9) AC Fan Motor DIMENSIONS (mm inch) NEW Earth tap M4 (200V class) 6 6- -4.3 .1 d 69 ia dia . . 300 min 11.811 min 82.5±0.3 3.248±.012 92.5 3.642 3.5 .138 RoHS Directive compatibility information http://www.nais-e.com/ 3.5 .138 25 +1 –0.3 +.039 .984–.012 3.5 .138 3.5 .138 25 +1 –0.3 +.039 .984–.012 82.5±0.3 3.248±.012 92.5 3.642 Airflow Airflow Lead wire type 2 terminals type RATING 1. Lead wire type, Standard speed Part number ASEN90211 ASEN90212 ASEN90214 ASEN90216 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 50/60 13/10 Rated current, max. (mA) 190/150 170/130 100/80 90/70 Locked current, max. (mA) 200/170 180/160 110/100 100/80 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2600/3100 0.80/0.98 43.1/60.8 34/39 (39/44) ±10 0.3 Rated current, max. (mA) 190/150 170/130 100/80 90/70 Locked current, max. (mA) 200/170 180/160 110/100 100/80 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2600/3100 0.80/0.98 43.1/60.8 34/39 (39/44) ±10 0.3 2. 2 terminals type, Standard speed Part number ASEN902519 ASEN902529 ASEN902549 ASEN902569 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 50/60 13/10 Notes: 1. Asterisks in the table above indicate minimum values. 2. Values above without designations are averages. 3. Noise level was measured at a distance of 1 m from side of fan. Values in brackets were measured at a distance of 1 m from front of fan. DATA (Airflow - Static pressure Characteristic Curve) Static pressure (Pa) 60 Hz 50 Hz 60 MATERIALS USED Frame: aluminum alloy die-casting Propeller: plastic Bearings: ball bearings Lead wires: UL3266 and AWG22 Terminal: Equivalent to Faston #110 Label: 100 V class...black base 200 V class...red base SPECIFICATIONS 40 20 0 0.2 0.4 0.6 0.8 1.0 Airflow (m3/min) Ambient temperature Ambient humidity Storage temperature Breakdown voltage Insulation resistance Insulation class Frequency Double amplitude width Vibration resistance Applied direction Applied time Protection Mean life 02/2006 –10°C to +60°C +14°F to +140°F 15 to 85%RH –20°C to +70°C –4°F to +158°F 1,500 V AC for 1 min. (between charging section and frame) Min. 100MΩ (at 500 V DC megger)(between charging section and frame) UL:A class, CSA:B class 10 to 55Hz 0.75mm X, Y and Z directions 10 min. in each direction Impedance protected MTTF: 50,000 hrs. (Time it takes until rotation frequency drops 30% of initial value when run continuously under 25°C 77°F and room humidity at the nominal voltage.) 7 120 sq.×25t (ASEN1) AC Fan Motor DIMENSIONS (mm inch) NEW Earth tap M4 (200V class) 300 min 11.811 min 8 8- -4. .1 3 d 69 ia di . a. 105±0.3 4.134±.012 119 4.685 RoHS Directive compatibility information http://www.nais-e.com/ 3.5 .138 3.5 .138 3.5 .138 25.5±0.5 1.004±.020 Airflow RATING 3.5 .138 105±0.3 4.134±.012 119 4.685 25.5±0.5 1.004±.020 Airflow Lead wire type 2 terminals type 1. Lead wire type, Standard speed Part number ASEN10211 ASEN10212 ASEN10214 ASEN10216 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 50/60 14/11 Rated current, max. (mA) 220/180 190/160 110/90 100/90 Locked current, max. (mA) 220/200 200/180 120/100 110/100 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2300/2700 1.8/2.0 41.2/41.2 34/38 (42/46) ±10 0.36 Rated current, max. (mA) 220/180 190/160 110/90 100/90 Locked current, max. (mA) 220/200 200/180 120/100 110/100 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2300/2700 1.8/2.0 41.2/41.2 34/38 (42/46) ±10 0.36 2. 2 terminals type, Standard speed Part number ASEN102519 ASEN102529 ASEN102549 ASEN102569 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 50/60 14/11 Notes: 1. Asterisks in the table above indicate minimum values. 2. Values above without designations are averages. 3. Noise level was measured at a distance of 1 m from side of fan. Values in brackets were measured at a distance of 1 m from front of fan. DATA (Airflow - Static pressure MATERIALS USED Characteristic Curve) 60 Static pressure (Pa) 60 Hz 50 Hz Frame: aluminum alloy die-casting Propeller: plastic Bearings: ball bearings Lead wires: UL3266 and AWG22 Terminal: Equivalent to Faston #110 Label: 100 V class...black base 200 V class...red base SPECIFICATIONS 40 20 0 0.7 1.5 Airflow (m3/min) 2.25 Ambient temperature Ambient humidity Storage temperature Breakdown voltage Insulation resistance Insulation class Frequency Double amplitude width Vibration resistance Applied direction Applied time Protection Mean life –10°C to +60°C +14°F to +140°F 15 to 85%RH –20°C to +70°C –4°F to +158°F 1,500 V AC for 1 min. (between charging section and frame) Min. 100MΩ (at 500 V DC megger)(between charging section and frame) UL:A class, CSA:B class 10 to 55Hz 0.75mm X, Y and Z directions 10 min. in each direction Impedance protected MTTF: 50,000 hrs. (Time it takes until rotation frequency drops 30% of initial value when run continuously under 25°C 77°F and room humidity at the nominal voltage.) 02/2006 8 120 sq.×38t (ASEN1) AC Fan Motor DIMENSIONS (mm inch) NEW 300 min 11.811 min Earth tap M4 (200V class) . dia ia. 4.3 69 d 8 .1 8- 105±0.3 4.134±.012 119 4.685 AIRFLOW 105±0.3 4.134±.012 119 4.685 38±0.5 1.496±.020 Airflow 38±0.5 1.496±.020 Airflow RoHS Directive compatibility information http://www.nais-e.com/ AIRFLOW 38±0.5 1.496±.020 Airflow Lead wire type 2 terminals type RATING 1. Lead wire type, Standard speed Part number ASEN10411 ASEN10412 ASEN10414 ASEN10416 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 15/14 15.5/14.5 15/13 15/14 50/60 Rated current, max. (mA) 270/230 250/210 140/120 120/100 Locked current, max. (mA) 370/300 320/270 190/170 160/140 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2600/2900 2.5/2.9 64.7/76.4 37/41 (44/48) ±10 0.55 Rated current, max. (mA) 270/230 250/210 140/120 120/100 Locked current, max. (mA) 370/300 320/270 190/170 160/140 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2600/2900 2.5/2.9 64.7/76.4 37/41 (44/48) ±10 0.55 2. 2 terminals type, Standard speed Part number ASEN104519 ASEN104529 ASEN104549 ASEN104569 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 15/14 15.5/14.5 15/13 15/14 50/60 Notes: 1. Asterisks in the table above indicate minimum values. 2. Values above without designations are averages. 3. Noise level was measured at a distance of 1 m from side of fan. Values in brackets were measured at a distance of 1 m from front of fan. DATA (Airflow - Static pressure Characteristic Curve) 300 Static pressure (Pa) 60 Hz 50 Hz Frame: aluminum alloy die-casting Propeller: plastic Bearings: ball bearings Lead wires: UL3266 and AWG22 Terminal: Equivalent to Faston #110 Label: 100 V class...black base 200 V class...red base SPECIFICATIONS 200 100 0 MATERIALS USED 0 2 4 6 Airflow (m3/min) Ambient temperature Ambient humidity Storage temperature Breakdown voltage Insulation resistance Insulation class Frequency Double amplitude width Vibration resistance Applied direction Applied time Protection Mean life 02/2006 –10°C to +60°C +14°F to +140°F 15 to 85%RH –20°C to +70°C –4°F to +158°F 1,500 V AC for 1 min. (between charging section and frame) Min. 100MΩ (at 500 V DC megger)(between charging section and frame) UL:A class, CSA:B class 10 to 55Hz 0.75mm X, Y and Z directions 10 min. in each direction Impedance protected MTTF: 50,000 hrs. (Time it takes until rotation frequency drops 30% of initial value when run continuously under 25°C 77°F and room humidity at the nominal voltage.) 9 150×172×38t (ASEN5) AC Fan Motor DIMENSIONS (mm inch) NEW Equivalent to Faston #110 Earth tap M4 (200V class) Airflow 162±0.2 172±1 6.378±.008 6.772±.039 a. di a. 3 di 4. 69 4 -.1 4 150 RoHS Directive compatibility information http://www.nais-e.com/ 6 .236 38±0.2 1.496±.008 5.906 RATING 2 terminals type, Standard speed Part number ASEN50751 ASEN50752 ASEN50754 ASEN50756 Rated voltage (V) 100 115 200 230 Frequency (Hz) Input power, +10 −20 % (W) 37/33 35/32 34/33 35/35 50/60 Rated current, max. (mA) 470/440 380/360 230/210 190/180 Locked current, max. (mA) 750/700 550/530 340/320 280/310 *Rotation speed (r/min) *Max. air flow (m3/min) *Max. static pressure (Pa) Noise (dB(A)) Operating voltage range (V) (%) Weight (kg) 2700/3200 5.0/6.0 157/215.8 52/56 (57/61) ±10 0.8 Notes: 1. Asterisks in the table above indicate minimum values. 2. Values above without designations are averages. 3. Noise level was measured at a distance of 1 m from side of fan. Values in brackets were measured at a distance of 1 m from front of fan. DATA (Airflow - Static pressure Characteristic Curve) 300 Static pressure (Pa) 60 Hz 50 Hz Frame: aluminum alloy die-casting Propeller: plastic Bearings: ball bearings Terminal: Equivalent to Faston #110 Label: 100 V class...black base 200 V class...red base SPECIFICATIONS 200 100 0 MATERIALS USED 0 2 4 6 Airflow (m3/min) Ambient temperature Ambient humidity Storage temperature Breakdown voltage Insulation resistance Insulation class Frequency Double amplitude width Vibration resistance Applied direction Applied time Protection Mean life –10°C to +60°C +14°F to +140°F 15 to 85%RH –20°C to +70°C –4°F to +158°F 1,500 V AC for 1 min. (between charging section and frame) Min. 100MΩ(at 500 V DC megger)(between charging section and frame) UL:A class, CSA:B class 10 to 55Hz 0.75mm X, Y and Z directions 10 min. in each direction Impedance protected MTTF: 50,000 hrs. (Time it takes until rotation frequency drops 30% of initial value when run continuously under 25°C 77°F and room humidity at the nominal voltage.) 02/2006 10 Accessories DIMENSIONS (mm inch) 1. Plug cord for AC Fan Motor 2 terminals type ASE51100 ASE51109 For inside of appliance Flat type 2-core cord (20/0.18) 9 .354 7.5 .295 23.5 .925 UL Standard: File No. E106219 Thermoplastic, flat type 2-core cord UL SPT-1 AWG18 (41/0.16) CSA POT-64 AWG18 (41/0.16) 1000±30 39.37±1.181 7 .276 9 .354 7.5 .295 10±5 .394±.197 15.5 .610 18 .709 8±0.1 .315±.004 23.5 .925 1000±30 39.37±1.181 7 .276 10±5 .394±.197 15.5 .610 18 .709 8±0.1 .315±.004 ASE51107 Compliant with Electrical Appliance and Material Safety Law Flat type 2-core cord (30/0.18) 9.3 .366 7.5 .295 20 .787 1000±30 39.37±1.181 7 .276 22 .866 10±5 .394±.197 16.7 .657 8±0.1 .315±.004 18.5 .728 ASFN88001 ASFN98001 Recognized for 40 sq. by UL/CSA Material used: Steel, 1.6 dia. Recognized for 80 sq. by UL/CSA Material used: Steel, 1.6 dia. Recognized for 92 sq. by UL/CSA Material used: Steel, 1.6 dia. . 4 dia ia. d .157 ia. d .1 29 dia. 1.146 14.2 .559 dia. dia. 2. Fan guard (You can use this with both DC and AC types.) ASFN48001 ASFN68001 Recognized for 60 sq. by UL/CSA Material used: Steel, 1.6 dia. 5.0 .197 4.8 .189 53.2 dia. 2.094 dia. 32 1.260 1.6 dia. .063 dia. 1.6 dia. .063 dia. 4.6 dia. .181 dia. 50.0 1.969 5.0 .197 5.0 .197 1.6 dia. .063 dia. 76.2 dia. 3.000 dia. 1.8 dia. .071 dia. 4.6 dia. .181 dia. 71.4 2.811 1.6 dia. .063 dia. 89.5 dia. 3.524 dia. 82.4 3.244 1.8 dia. .071 dia. 4.6 dia. .181 dia. ASEN88001 ASEN98001 ASEN18001 ASEN58001 For 80 sq. by Electrical Appliance and Material Safety Law Material used: Steel, 1.6 dia. For 92 sq. by Electrical Appliance and Material Safety Law Material used: Steel, 1.6 dia. For 120 sq. by Electrical Appliance and Material Safety Law Material used: Steel, 1.6 dia. Recognized for 150×172 by UL/CSA Material used: Steel, 2.3 dia. 4.3 .169 4.3 .169 4.3 .169 1.6 dia. .063 dia. 1.6 dia. .063 dia. 105 4.134 5.0 .197 1.6 dia. .063 dia. 121 4.764 80 dia. 3.150 dia. 30 dia. 1.181 dia. 30 dia. 1.181 dia. 90 dia. 3.543 dia. 1.8 dia. .071 dia. 2.3 dia. .091 dia. 60.2 2.370 5.0 .197 4.8 .18 dia. 9d ia. 5.0 .197 152.5 6.004 108 dia. 4.252 dia. 30 dia. 1.181 dia. 154.4 dia. 6.079 dia. 162.05 6.380 3. Fan motor filter (You can use this with both DC and AC types.) ASEN68002 ASEN88002 ASEN98002 ASEN18002 For 60 sq. For 120 sq. For 80 sq. 83.6 3.291 71.5 2.815 . dia . 3.8 0 dia .15 dia. 3.8 0 dia. .15 10 .394 10 .394 02/2006 123.7 4.870 104.8 4.126 96.5 3.799 82.5 3.248 . dia . 4.5 7 dia .17 123.7 4.870 104.8 4.126 96.5 3.799 82.5 3.248 83.6 3.291 71.5 2.815 60 2.362 50 1.969 60 2.362 50 1.969 6.4 .252 For 92 sq. 6.45 .254 . dia ia. 4.577 d 1 . 10.7 .421 11 Mounting Hole Dimensions For DC Fan Motor 1. 30 sq. Series Discharge side/Suction side 2. 40 sq. Series Discharge side/Suction side 4-3.2 dia. 4-.126 dia. 4-4.3 dia. 4-.169 dia. 3 1. 9.0 53 5 .0 5 39 .53 1 38.6 32.0 1.520 1.260 24.0 .945 28.0 1.102 58.0 50.0 2.283 1.969 . dia ia. .0 d 65 .559 2 32.0 1.260 38.6 1.520 4. 80 sq. Series Discharge side/Suction side 5. 92 sq. Series Discharge side/Suction side 6. 120 sq. Series Discharge side/Suction side 115.0 4.528 4-4.3 dia. 4-.169 dia. 4-4.3 dia. 4-.169 dia. 105.0 4.134 . . dia dia 85 .346 3 77.6 71.5 3.055 2.815 58.0 2.283 50.0 1.969 4-3.5 dia. 4-.138 dia. 2 1. 9.0 14 2 28.0 24.0 1.102 .945 3. 60 sq. Series Discharge side/Suction side a. di . 4 ia 6. 9 d 0 8 1 .1 4 89.4 82.5 3.520 3.248 a. di . 0 dia . 6 1 12 .96 4 115.0 4.528 105.0 4.134 71.5 2.815 77.6 3.055 4-4.3 dia. 4-.169 dia. 82.5 3.248 89.4 3.520 For AC Fan Motor 1. 60 sq. Series Discharge side/Suction side 2. 80 sq. Series Discharge side/Suction side 50 1.969 77 71.5 3.031 2.815 50 1.969 . a. dia di 88 .465 3 71.5 2.815 77 3.031 4. 120 sq. Series Discharge side/Suction side 4-4.3 dia. 4-.169 dia. 4-4.3 dia. 4-.169 dia. 4-4.3 dia. 4-.169 dia. dia. 58.5 dia. 3 2.30 3. 92 sq. Series Discharge side/Suction side 89 82.5 3.504 3.248 . . dia dia 6 10 .173 4 82.5 3.248 89 3.504 5. 150×172 Series Discharge side/Suction side 2-4.3 dia. 2-.169 dia. 4-4.3 dia. 4-.169 dia. ia. . 6 d dia 13 354 5. 115 105 4.528 4.134 105 4.134 115 4.528 a. . di dia 2 15 .984 5 162 6.378 146 5.748 02/2006 12 Functions of DC Fan Sensor DC FAN SENSOR If the fan stops as a result of forced external restraint, a signal will be generated to indicate that there is a problem. This signal can be used to control an external warning circuit in order to help prevent the device from overheating. Although there are various detection methods for this sensor, we employ the method that uses a logic circuit. 1. Lock sensor specifications Output waveform Approx. 5 sec. or less 2. Sensor output circuit Vcc Approx. 5 sec. or less Red VOH White Power supply Sensor output Ic R Rating of sensor VOL 0V s Fan rotating Fan stopped (locked) Fan rotating Black * Output may be high for approximately 0.5 seconds when power is turned on. * The continually high output waveform type when fan is stopped (locked) is standard. A high/low output waveform type and output waveform type that corresponds to the rotation frequency during fan rotation are available by special order. Please inquire for details. 02/2006 Power supply • Sensor output: Open collector output Max. 30 V • Vcc: Max. 5 mA • Ic: Notes: 1. Set the resistance value (R) so that the sensor circuit current (Ic) does not exceed 5 mA. 2. When using at TTL level, the sensor circuit current (Ic) should be approximately 2 mA. * Exceeding the values above may lead to IC damage. 13 Cautions For Use DC FAN MOTOR 1. Do not reverse-connect the power supply. Although nothing adverse will occur if the rated voltage is connected in reverse for a short time period, the fan will not operate. 2. If the power is to be pulsed on and off in order to start and stop the fan quickly, be sure to install a switch on the + side of the power supply. Not doing so may damage the circuit. 3. The DC fan motor installation bracket has a rib. As shown in the figure, use the through-bolts when installing. 4. Use a tightening torque of no more than 0.6 Nm. Through-bolt Fan motor Installation surface DC FAN MOTOR and AC FAN MOTOR 1. Since our fan motor employs precision ball bearings, due care should be taken not to apply any shock in handling. 2. Due to the bearing mechanism, the noise level will increase in proportion to the length of time the fan is used. Avoid use where the temperature is high or where there is a lot of dirt. 3. Do not allow substances such as oil and grease to get onto the plastic part of the fan body. Some oils and greases decompose and become altered at high temperatures. These can have an adverse effect if they contact the fan. Therefore, be very careful when handling these substances. 4. Do not apply unnecessary force to the internal parts when handling the product. Also, do not use a fan that has been dropped. 5. Fan life is based on usage at room temperature and a humidity of 15 to 45% RH. Please verify life under actual conditions, since life will depend on the frequency and duration of use, as well as the atmosphere in which it is used. 6. Transport and storage conditions The allowable specifications for environments suitable for transportation and storage are given below. Humidity (%RH) 85 No freezing No condensation 30 15 –20 0 40 70 Temperature (°C) Storage temperature range • No freezing between –20°C to 0°C –4°F to +32°F • No condensation in the range above between 0°C to +70°C +32°F to +158°F 02/2006 1) Condensation If the temperature is high and there is a lot of humidity, condensation will occur when the temperature suddenly changes. This should be avoided because it can cause degradation of the fan insulation. 2) Freezing At temperatures below 0°C +32°F moisture such as that caused by condensation will freeze and lead to problems such as lockage of the moving parts and operation lags. Be careful to prevent this from happening. 3) Low-temperature, low-humidity environments Do not leave the fan for a long period in an environment of low temperature and low humidity. Doing so may cause the plastic to become brittle. 4) When storing, avoid places of high temperature and high humidity or where corrosive gas is present. 5) Do not store the fan any longer than six months. 14 Technical Information MEASUREMENT of AIRFLOW and STATIC PRESSURE It is very difficult to measure airflow and static pressure, and there are cases where measured values vary depending on measuring devices. There are two kinds of measuring methods; double chamber method provided by JIS and AMCA (Air Moving and Conditioning Association) and wind tunnel method. Our company adopted the double chamber method, and therefore we will explain it hereinafter. The auxiliary blower (fan) adjusts an inner pressure by sucking out air. At this moment, as airflow and static pressure are varied by opening or closing the damper, each value is read on the manometer. Maximum airflow: The damper opens, and the auxiliary blower sucks out air so that static pressure becomes zero. At this moment, the pressure differential (airflow differential pressure: Pn) in chambers A and B becomes maximum. The airflow whose Pn is measured and which is determined by using the equation shown at right is called the maximum airflow. Maximum static pressure: When the damper is completely closed, the pressure in chamber A becomes maximum. At this moment, the pressure differential (static pressure: Ps) in chambers A against atmospheric pressure is called the maximum static pressure. Double chamber measuring device Static pressure manometer Ps Pn Auxiliary blower Chamber A Measured fan Airflow adjusting damper Chamber B Nozzle 2. Unit conversion table 1) Airflow 1. Equation Airflow Q = In the above equation, C: Flow coefficient of nozzle D: Nozzle diameter (m) γ: Air density = m3/min. l/s 1 0.06 0.0283 16.678 1 0.472 CFM (ft3/min.) 35.334 2.1186 1 2) Static pressure Pa 1 9.80665 mmH2O (mmAq) 0.10197 1 t: Temperature(°C) P: Atmospheric pressure(Pa) g: 9.8(m/s2) Pn: Airflow differential pressure (Pa) Ps: Static pressure (Pa) NOISE MEASUREMENT Operation noise is measured by hanging the fan in midair. For the DC fan, noise is measured in dB(A) 1 m from the front of the air-intake side. For the AC fan, noise is measured in dB(A) 1 m from the front of the air-intake side and the side of the fan. Airflow manometer The background noise complies with the section in JIS B8346 that states that it should be at least 10 dB lower than the target noise reading. Our measurements were made in an anechoic chamber with a background noise of approximately 15 dB. DC FAN MOTOR 1 m 3.281 ft (AC FAN MOTOR 1 m 3.281 ft) Fan motor Microphone AC FAN MOTOR 1 m 3.281 ft Microphone COUNTERMEASURES AGAINST MOISE Our fan motors are designed placing great importance on low noise. However, take into consideration the following points because noise is influenced depending on the mechanism design used. 1) Leave a space between the rear side of the fan suction opening and the cooled object. 2) When using two or more fan motors, leave a space between the fans. 3) According to the mounting hole dimensions (page 22), design so that the mounting face and blades are not crossed. 4) Grease in the bearings will deteriorate and noise will gradually increase as the fan is used. The replacement period will differ depending on the conditions of use and allowable sound level. We recommend periodic replacement. Fan motor 02/2006 15 Technical Information When selecting a fan motor, for normal use the following method is used. 1) Determine the amount of heat generated inside the equipment. 2) Decide the permissible temperature rise inside the equipment. Equipment Fan motor T2 H T1 Heat generating section 3) Calculate the volume of air necessary from Equation (1). Equation (1) where Q: Air volume (m3/min.) H: Heat generated (kW) T1: Inlet air temperature(°C) T2: Exhaust air temperature(°C) ∆T: Temperature rise(°C) 4) Determine the system impedance of the equipment by means of Equation (2). For the flow of air to the equipment, there is a loss of pressure due to the resistance to the flow of air from the components inside the equipment. This loss varies in accordance with the flow of air. This is referred to as the system impedance. ∆P=KQn.........Equation (2) where ∆P: Pressure drop(Pa{mmH2O}) K: Constant determined for each equipment Q: Air volume (m3/min.) n: Coefficient determined by air flow In this equation, it is generally considered that n = 2. Also, it is difficult to calculate the value of K, since there is no good method other than an actual test measurement with the equipment. Example: When the heat generated is 100 W with ∆T = 10°C 50°F, the following is the result. Static pressure (Pa{mmH2O}) METHOD OF SELECTING FAN MOTOR Air volume/static pressure characteristic curve System impedance curve Operating point ∆P 0.5 Air volume (m3/min.) The intersection of the air volume/static pressure characteristic curve with the system impedance curve is called the operating point. This shows the condition with the fan motor operating. In actuality, the system impedance is approximately assumed, a fan motor is decided from the catalogue, the temperature difference “∆T” and air volume “Q” are measured, and from this data the fan is judged as suitable or not as the ordinary method. If the temperature difference “∆T” is high indicating the air volume “Q” is not satisfactory, because the system impedance is higher than the assumed value, a change should be made to a fan motor with a greater air volume. FAN MOTOR SERIES/PARALLEL OPERATION 2. In case of parallel operation 1. In case of series operation R AI R R AI Rise in pressure Static pressure (Pa) AI Static pressure (Pa) When one fan motor does not satisfy a sufficient cooling capacity; Series operation: Higher pressure characteristic obtained. (Nearly double) Parallel operation: Larger airflow characteristic obtained. (Nearly double) High system impedance In case of one unit When two units are put into series operation Low system impedance Increase in airflow Airflow (m3/min.) • In case of high system impedance, static pressure rises. • In case of low system impedance, airflow slightly increases. 02/2006 Rise in pressure High system impedance When two units are put into parallel operation In case of one unit Increase in airflow Low system impedance Airflow (m3/min.) • In case of low system impedance, airflow increases. • In case of high system impedance, pressure slightly rises. 16
ASEN60512 价格&库存

很抱歉,暂时无法提供与“ASEN60512”相匹配的价格&库存,您可以联系我们找货

免费人工找货