0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ASQ10328

ASQ10328

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SWSNAPACTSPST-NC100MA20V

  • 数据手册
  • 价格&库存
ASQ10328 数据手册
TURQUOISE STROKE SWITCHES Long Stroke and Sliding Contact Construction Sealed Switches 13.3 5.4 10.1 (Unit: mm) RoHS compliant FEATURES TYPICAL APPLICATIONS • For pin plunger type, it maintains a long stroke OT (Over Travel) with over 2.2 mm on the NO side and over 2.5 mm on the NC side. • Since contact force does not depend on the operation stroke, the range of possible use over the entire stroke is greatly increased. • High contact reliability to support low level switching loads • Highly effective sealing for resistance against adverse environments • Silent operation with sliding contact • Automobiles (detection of door opening and closing and shift lever position, etc.) • Household appliances (vacuum cleaners, air conditioners, washing machines, etc.) ORDERING INFORMATION ASQ1 Size of mounting hole 0: Mounting hole 3 mm standard type 1: Mounting hole 3 mm without boss type 4: Right side pin type (solder terminal only) 5: Left side pin type (solder terminal only) 6: Right 2 boss type (solder terminal only) 7: Left 2 boss type (solder terminal only) Terminal 2: Wire leads right side type (SPST-NC and SPST-NO only) 3: Wire leads left side type (SPST-NC and SPST-NO only) Contact form 1: SPDT 2: SPST-NC 3: SPST-NO (wire lead type only) (wire lead type only) COM NO 4: Solder terminal 5: PC board terminal 7: PC board right angle terminal NC COM NC COM NO Actuator 0: Pin plunger 7: Leaf lever 8: Simulated leaf lever 6: Wire leads bottom type 8: PC board left angle terminal Note: Not every combination is available. Please refer to the following table, “PRODUCT TYPES”. PRODUCT TYPES ■ Terminal type (Mounting hole 3mm standard type/Mounting hole 3mm without boss type/2 boss type/Side pin type) Actuator Pin plunger Leaf lever Simulated leaf lever Operating Force OF (Max.) 1.5N 1.7N 1.5N Mounting hole 3mm standard type Solder terminal ASQ10410 ASQ10417 ASQ10418 PC right angle terminal ASQ10710 ASQ10717 ASQ10718 PC left angle terminal ASQ10810 ASQ10817 ASQ10818 –1– Mounting hole 3mm without boss type Right 2 boss type Left 2 boss type Right side pin type Left side pin type PC board terminal Solder terminal Solder terminal Solder terminal Solder terminal ASQ11510 ASQ11517 ASQ11518 ASQ16410 ASQ16417 ASQ16418 ASQ17410 ASQ17417 ASQ17418 ASQ14410 ASQ14417 ASQ14418 ASQ15410 ASQ15417 ASQ15418 AECTB6E 201408-T Turquoise Stroke Switches (ASQ1) ■ Wire leads bottom type (Mounting hole 3mm standard type) Actuator Operating Force OF (Max.) Pin plunger Leaf lever Simulated leaf lever 1.5N 1.7N 1.5N SPDT ASQ10610 ASQ10617 ASQ10618 Wire leads bottom type (Mounting hole 3mm standard type) SPST-NC ASQ10620 ASQ10627 ASQ10628 SPST-NO ASQ10630 ASQ10637 ASQ10638 ■ Wire leads side type (Mounting hole 3mm standard type) Actuator Operating Force OF (Max.) Pin plunger Leaf lever Simulated leaf lever 1.5N 1.7N 1.5N Wire leads right side type (Mounting hole 3mm standard type) SPST-NC SPST-NO ASQ10220 ASQ10230 ASQ10227 ASQ10237 ASQ10228 ASQ10238 Wire leads left side type (Mounting hole 3mm standard type) SPST-NC SPST-NO ASQ10320 ASQ10330 ASQ10327 ASQ10337 ASQ10328 ASQ10338 SPECIFICATIONS ■ Contact rating 1 mA 5 V DC to 100 mA 30 V DC Note: Please consult us regarding 42 V DC rating. ■ Operation environment and conditions Item Ambient and storage temperature Allowable operating speed Max. operating cycle rate Specifications –40°C to +85°C (no freezing and condensing) 30 to 500 mm/sec. 120 cpm Note: When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly depending on the load capacity. Please consult us. ■ Electrical characteristics Dielectric strength (Initial) Insulation resistance (Initial) Contact resistance (Initial) Between non-continuous terminals: 600 Vrms, Between each terminal and other exposed metal parts: 1,500 Vrms, Between each terminal and ground: 1,500 Vrms (at detection current of 1 mA) Min. 100 MΩ (at 500 V DC insulation resistance meter) (Locations measured same as dielectric strength.) Max. 1 Ω (by voltage drop 0.1 A 6 to 8 V DC) ■ Characteristics Item Electrical switching life 5 V DC 1 mA (Resistive load) 16 V DC 50 mA (Resistive load) 30 V DC 100 mA (Resistive load) Vibration resistance (malfunction vibration resistance) Shock resistance (malfunction shock resistance) Vibration resistance endurance Terminal strength Heat resistance Cold resistance Humidity resistance Thermal shock resistance Unit weight Protection grade Specifications Switching frequency: 20 times/min. Conduction ratio: 1:1 Min. 5 × 105 Pushbutton operation speed: 100 mm/s 5 Min. 2 × 10 Pushbutton switching position: free position (FP) to operation limit position (TTP) Single amplitude: 0.75 mm Amplitude of vibration: 10 to 55 Hz (4 minutes cycle) Direction and time: 30 minutes each in X, Y and Z directions Amplitude of vibration: 5 to 200 Hz (10 minutes cycle) Acceleration: 43.1 m/s2 Direction and time: 30 minutes each in X, Y and Z directions Shock value: 980 m/s2 Direction and time: 5 times each in X, Y and Z directions Min. 5 × 105 Frequency of vibration: 33.3 Hz, Acceleration: 43.1 m/s2 Direction and time: 8 hours each in X, Y and Z directions 6 N min. (each direction) *Terminal deformation possible. 85°C 500 hours –40°C 500 hours 40°C 95% RH 500 hours 30 min. at 85°C to 30 min at –40°C for 1,000 cycles Approx. 0.8 g (terminal type), Approx. 5.4 g (wire leads side type) IP67 (except exposed terminal part of terminal type) Note: As long as there are no particular designations, the following conditions apply to the test environment. • Ambient temperature: 5 to 35°C • Relative humidity: 25 to 85% RH • Air pressure: 86 to 106 kPa –2– AECTB6E 201408-T Turquoise Stroke Switches (ASQ1) ■ Protection gread 1) JIS C0920: Waterproof type A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes under 1 m of water (with temperature difference between water and switch no larger than 5°C). 2) IEC 60529: IP67 (waterproof type) A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes under 1 m of water (with temperature difference between water and switch no larger than 5°C). 3) JIS D0203: Equivalent of D2 A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes under 10 cm of water (with temperature difference between water and switch no larger than 30°C). ■ Operating characteristics Characteristics Operating Force (max. OF) *Note 2 Total travel Force (max. TF) (reference value) From mounting boss and hole center line Free Position (max. FP) From standoff From mounting boss and hole center line Operating Position on NC side OP (NC) *Note 3 From standoff From mounting boss and hole center line Operating Position on NO side OP (NO) *Note 4 From standoff From mounting boss and hole center line Release Position on NC side RP (NC) *Note 5 From standoff From mounting boss and hole center line Release Position on NO side RP (NO) *Note 6 From standoff Over travel on NC side (min. OT (NC)) Over travel on NO side (min. OT (NO)) From mounting boss and hole center line Total Travel Position (TTP) (reference value) From standoff Unit N N mm mm mm mm mm mm mm mm Pin plunger 1.5 (2.0) 9.2 13.4 8.7±0.3 12.9±0.3 8.4±0.3 12.6±0.3 8.8±0.3 13.0±0.3 8.5±0.3 12.7±0.3 2.5 2.2 (5.9) (10.1) Leaf lever 1.7 (3.1) 11.5 15.7 9.8±0.5 14.0±0.5 9.3±0.5 13.5±0.5 10.1±0.5 14.3±0.5 9.6±0.5 13.8±0.5 3.1 2.6 (6.2) (10.4) Simulated leaf lever 1.5 (2.8) 14.4 18.6 12.5±0.5 16.7±0.5 12.0±0.5 16.2±0.5 12.9±0.5 17.1±0.5 12.4±0.5 16.6±0.5 3.3 2.8 (8.7) (12.9) Notes: 1. The above indicates the characteristics when operating the pushbutton from the vertical direction. 2. Indicates operation load for NO contact to achieve ON status. 3. Indicates position for NC contact to achieve OFF status. 4. Indicates position for NO contact to achieve ON status. 5. Indicates position for NC contact to achieve ON status. 6. Indicates position for NO contact to achieve OFF status. OPERATION CONCEPT DIAGRAM Contact form: terminal type Operation load Operation load Standard (mounting boss and hole center diameter or standoff) TF OF RF 0 RP (NC) OP (NC) NC side Contact force OT (NC) 0 (OFF) Stroke NO side TTP OT (NO) OP (NO) RP (NO) FP Range of possible use NC side NO side DATA Applicable current range (Reference) 100mA Applicable range 1mA 0 DC 5V 30V –3– AECTB6E 201408-T Turquoise Stroke Switches (ASQ1) DIMENSIONS (Unit: mm) General tolerance: ±0.25 The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ ■ Terminal type: Mounting hole 3 mm, standard type Pin plunger External dimensions CAD Data Operating Force (max. OF) Free Position (max. FP) FP 9.2 MAX. RP (NC) 8.8±0.3 OP (NC) 8.7±0.3 RP (NO) 8.5±0.3 OP (NO) 8.4±0.3 TTP (5.9) C0.3 8.4±0.2 13.3±0.15 5.4±0.15 5.4 2.7 1.9 dia. 3.0+0.1 –0 5.1 5.9 TTP (10.1) RP (NO) 12.7±0.3 OP (NO) 12.6±0.3 FP 13.4 MAX. RP (NC) 13.0±0.3 OP (NC) 12.9±0.3 3.2±0.1 3.7 4.2 8.3±0.1 3.0+0.3 –0.2 3.0 +0 –0.1 dia. 1.2 2.0 1.5 0.4 0.4 4.1 1.5N From mounting boss and hole center line 9.2mm From standoff 13.4mm Operating Position on NC side OP (NC) From mounting boss and hole center line 8.7±0.3mm From standoff 12.9±0.3mm Operating Position on NO side OP (NO) From mounting boss and hole center line 8.4±0.3mm From standoff 12.6±0.3mm Release Position on NC side RP (NC) From mounting boss and hole center line 8.8±0.3mm From standoff 13.0±0.3mm Release Position on NO side RP (NO) From mounting boss and hole center line 8.5±0.3mm From standoff 12.7±0.3mm Over travel on NC side (min. OT (NC)) Over travel on NO side (min. OT (NO)) 2.5mm 2.2mm 4.53±0.15 4.53±0.15 ■ Terminal type: Leaf lever External dimensions CAD Data Operating Force (max. OF) FP 11.5 MAX. RP (NC) 10.1±0.5 OP (NC) 9.8±0.5 RP (NO) 9.6±0.5 OP (NO) 9.3±0.5 TTP (6.2) C 0. 3 Free Position (max. FP) 13.3±0.15 5.4 2.7 1.9 dia. (18 °) 0.5 14.0 0.2 FP 15.7 MAX. RP (NC) 14.3±0.5 OP (NC) 14.0±0.5 RP (NO) 13.8±0.5 OP (NO) 13.5±0.5 TTP (10.4) 8.4±0.2 5.4±0.15 3.3 3.2±0.1 R1.2 1.2 3.0+0.1 –0 3.7 4.2 8.3±0.1 +0 –0.1 3.0 5.1 5.9 3.0+0.3 –0.2 dia. 1.2 2.0 1.5 0.4 0.4 4.1 1.7N From mounting boss and hole center line 11.5mm From standoff 15.7mm Operating Position on NC side OP (NC) From mounting boss and hole center line 9.8±0.5mm From standoff 14.0±0.5mm Operating Position on NO side OP (NO) From mounting boss and hole center line 9.3±0.5mm From standoff 13.5±0.5mm Release Position on NC side RP (NC) From mounting boss and hole center line 10.1±0.5mm From standoff 14.3±0.5mm Release Position on NO side RP (NO) From mounting boss and hole center line 9.6±0.5mm From standoff 13.8±0.5mm Over travel on NC side (min. OT (NC)) Over travel on NO side (min. OT (NO)) 3.1mm 2.6mm 4.53±0.15 4.53±0.15 Note: When switching at high speed or under shock, lever endurance may drop. Therefore, please be sure to conduct an endurance evaluation under actual switching conditions. –4– AECTB6E 201408-T Turquoise Stroke Switches (ASQ1) ■ Terminal type: Simulated leaf lever External dimensions CAD Data Operating Force (max. OF) C 0. 3 2.8 13.3±0.15 R2.0 FP 14.4 MAX. RP (NC) 12.9±0.5 OP (NC) 12.5±0.5 RP (NO) 12.4±0.5 OP (NO) 12.0±0.5 TTP (8.7) Free Position (max. FP) 8.4±0.2 5.4±0.15 3.3 5.4 2.7 1.9dia. °) (18 15.0 R0.5 0.5 R1.2 FP 18.6 MAX. RP (NC) 17.1±0.5 OP (NC) 16.7±0.5 RP (NO) 16.6±0.5 OP (NO) 16.2±0.5 TTP (12.9) 0.2 1.2 3.2±0.1 3.0+0.1 –0 5.1 5.9 3.7 4.2 8.3±0.1 3.0+0.3 –0.2 0.4 1.2 2.0 1.5 0.4 From mounting boss and hole center line 14.4mm From standoff 18.6mm Operating Position on NC side OP (NC) From mounting boss and hole center line 12.5±0.5mm From standoff 16.7±0.5mm Operating Position on NO side OP (NO) From mounting boss and hole center line 12.0±0.5mm From standoff 16.2±0.5mm Release Position on NC side RP (NC) From mounting boss and hole center line 12.9±0.5mm From standoff 17.1±0.5mm Release Position on NO side RP (NO) From mounting boss and hole center line 12.4±0.5mm From standoff 16.6±0.5mm Over travel on NC side (min. OT (NC)) Over travel on NO side (min. OT (NO)) 3.0+0 –0.1 dia. 4.1 1.5N 3.3mm 2.8mm 4.53±0.15 4.53±0.15 Note: When switching at high speed or under shock, lever endurance may drop. Therefore, please be sure to conduct an endurance evaluation under actual switching conditions. ■ PC board terminal: Mounting hole 3 mm without boss type PC board terminal CAD Data 3.0+0.3 −0.2 0.9 C0.2 5.08±0.15 5.08±0.15 PC board pattern 1.0+0.1 −0 dia. 5.08±0.1 5.08±0.1 ■ Terminal type: Right side pin type External dimensions CAD Data 8.3 C 0. 2 2.6±0.05 2.2±0.05 dia. 13.3±0.15 5.4 2.7 5.4±0.15 5.0 +0.3 1.2 2.0 4.53±0.15 1.5 0.4 3.0−0.2 3.7 4.2 5.1 5.9 2.6±0.05 1.9 dia. TTP (5.9) FP 9.2 MAX. FP 13.4 MAX. RP (NC) 13.0±0.3 OP (NC) 12.9±0.3 RP (NO) 12.7±0.3 OP (NO) 12.6±0.3 TTP (10.1) RP (NC) 8.8±0.3 OP (NC) 8.7±0.3 RP (NO) 8.5±0.3 OP (NO) 8.4±0.3 8.3±0.1 0.4 4.1 4.53±0.15 –5– AECTB6E 201408-T 2-3 .0 . 5.1 5.9 3 0. C +0.3 3.0−0.2 3.7 4.2 5.1 5.9 4.53±0.15 CAD Data 1.2 2.0 4.53±0.15 8.3±0.1 1.2 2.0 4.53±0.15 1.5 0.4 TTP (5.9) RP (NC) 8.8±0.3 OP (NC) 8.7±0.3 RP (NO) 8.5±0.3 OP (NO) 8.4±0.3 1.5 0.4 1.2 2.0 3.7 4.2 TTP (5.9) FP 9.2 MAX. +0.3 3.0−0.2 3.7 4.2 8.3±0.1 2.6±0.05 5.1 5.9 TTP (5.9) FP 9.2 MAX. FP 13.4 MAX. RP (NC) 13.0±0.3 OP (NC) 12.9±0.3 RP (NO) 12.7±0.3 OP (NO) 12.6±0.3 TTP (10.1) RP (NC) 8.8±0.3 OP (NC) 8.7±0.3 RP (NO) 8.5±0.3 OP (NO) 8.4±0.3 8.3 1.5 0.4 dia RP (NC) 8.8±0.3 OP (NC) 8.7±0.3 RP (NO) 8.5±0.3 OP (NO) 8.4±0.3 CAD Data +0.3 3.0−0.2 + −00 .1 FP 9.2 MAX. FP 13.4 MAX. RP (NC) 13.0±0.3 OP (NC) 12.9±0.3 RP (NO) 12.7±0.3 OP (NO) 12.6±0.3 TTP (10.1) CAD Data 2 0. 2.2±0.05 dia. 2.6±0.05 C 3 0. C FP 13.4 MAX. RP (NC) 13.0±0.3 OP (NC) 12.9±0.3 RP (NO) 12.7±0.3 OP (NO) 12.6±0.3 TTP (10.1) Turquoise Stroke Switches (ASQ1) ■ Terminal type: Left side pin type External dimensions 8.3±0.1 5.4 2.7 13.3±0.15 5.0 5.4 2.7 5.4 2.7 1.5 –6– 5.4±0.15 1.9 dia. 4.1 0.4 4.53±0.15 ■ Terminal type: Right 2 boss type External dimensions 2-3.0 −0.1 dia. +0 13.3±0.15 5.4±0.15 1.5 1.9 dia. 4.1 0.4 4.53±0.15 ■ Terminal type: Left 2 boss type External dimensions 13.3±0.15 5.4±0.15 1.9 dia. 4.1 0.4 4.53±0.15 AECTB6E 201408-T Turquoise Stroke Switches (ASQ1) ■ Angle terminal type: Mounting hole 3 mm, standard type (Right type) External dimensions CAD Data C 5.08±0.15 2 0. 5.08±0.15 0.9 NO NC C RP (NC) 8.8±0.3 OP (NC) 8.7±0.3 RP (NO) 8.5±0.3 OP (NO) 8.4±0.3 0. 3 COM 13.3±0.15 8.4±0.2 5.4 5.4±0.15 2.7 1.9 dia. 3.7 4.2 6.0±0.3 3.0 −0 5.1 5.9 +0.1 TTP (5.9) FP 9.2 MAX. 3.2±0.1 4.1 2.0 3.95±0.15 0.4 3.0 + − 0 0.1 dia . 8.3±0.1 3.1±0.4 ■ Angle terminal type: Mounting hole 3 mm, standard type (Left type) External dimensions CAD Data C 0. 3 COM 0.9 NO .2 C 0 NC 5.08±0.15 RP (NC) 8.8±0.3 OP (NC) 8.7±0.3 RP (NO) 8.5±0.3 OP (NO) 8.4±0.3 5.08±0.15 13.3±0.15 8.4±0.2 5.4 5.4±0.15 2.7 1.9 dia. 5.9 4.2 6.0±0.3 3.0−0 5.1 3.7 +0.1 TTP (5.9) 3.95±0.15 2.0 0.4 + −00 .1 dia . 8.3±0.1 3.0 FP 9.2 MAX. 3.2±0.1 4.1 3.1±0.4 –7– AECTB6E 201408-T Turquoise Stroke Switches (ASQ1) ■ Wire leads bottom type: Mounting hole 3 mm, standard type External dimensions FP 9.2 MAX. OP (NC) 8.7±0.3 OP (NO) 8.4±0.3 TTP (5.9) CAD Data 8.4±0.2 C 0.3 13.3±0.15 5.4±0.15 5.4 2.7 1.9 dia. 3.2±0.1 3.0+0.1 −0 5.1 5.9 3.7 8.3±0.1 3.0+0 −0.1 dia. 4.3 3.2 R 0.2 4.2 R 0.3 2.2 0.3 2.6 0.3 3.6 1.4 dia. 4.53 4.53 ∗ Wire lead thickness : Wire lead color : : : 5.2 300±10 5.0±2 0.3mm2 COM ···· Black NC ······· Red NO ······· White ■ Wire leads right side type: Mounting hole 3 mm, standard type External dimensions FP 9.2 MAX. OP (NC) 8.7±0.3 OP (NO) 8.4±0.3 TTP (5.9) CAD Data R 0.5 C 0.3 8.4±0.2 13.3±0.15 5.4±0.15 5.4 2.7 1.9 dia. 3.2±0.1 +0.1 −0 3.0 5.1 5.9 3.0+0 −0.1 dia. 3.7 8.3±0.1 1.4 dia. R 0.5 R 2.0 R 0.5 0.3 2.4 ∗ Wire lead thickness : Wire lead color : : : 4.5 4.3 1.0 5.0±2 0.3mm2 COM ···· Black NC ······· Red NO ······· White 5.2 300±10 ■ Wire leads left side type: Mounting hole 3 mm, standard type CAD Data External dimensions FP 9.2 MAX. OP (NC) 8.7±0.3 OP (NO) 8.4±0.3 TTP (5.9) R 0.5 8.4±0.2 5.4±0.15 1.9 dia. C 0.3 13.3±0.15 5.4 2.7 3.2±0.1 3.0+0.1 −0 5.1 5.9 R 0.5 1.4 dia. 3.7 8.3±0.1 4.5 1.0 5.0±2 R 2.0 R 0.5 5.2 3.0+0 −0.1 dia. 300±10 2.4 –8– 4.3 ∗ Wire lead thickness : Wire lead color : : : 0.3mm2 COM ···· Black NC ······· Red NO ······· White 0.3 AECTB6E 201408-T Turquoise Stroke Switches (ASQ1) CAUTIONS FOR USE ■ Soldering conditions The application of excessive heat upon the switch when soldering can cause degradation of switch operation. Therefore, be sure to keep within the conditions given below. Manual soldering: use soldering irons (max. 350°C, within 3 seconds at each terminal) capable of temperature adjustment. This is to prevent deterioration due to soldering heat. Care should be taken not to apply force to the terminals during soldering. (More than one second interval is required to apply heat at each terminal.) ■ Mounting Please avoid use in which load would be applied to the sides (hatch part (both sides) shown below) of the switch in the direction indicated by the arrows. This could cause erroneous operation. Also, when using a metal installation board, please make allowance for burr direction designation and burr suppressing, etc., so that the burr side will not be on the switch installation side. 1) To secure the switch, please use an M3 small screw on a flat surface and tighten using a maximum torque of 0.29 N·m. It is recommended that both flat metal washer and spring washers be used with the screws and adhesive be applied to lock the screws to prevent loosening of the screws. Please make sure not to apply adhesive onto the moving parts. 2) Be sure to maintain adequate insulating clearance between each terminal and ground. 3) Although it is possible to directly operate the pin plunger type from the lateral direction, please consult us if doing so. 4) After mounting please make sure no tensile load will be applied to the switch terminals. 5) Range of possible use: Please set the operation position to within the ranges in the following table so that there is sufficient insulation distance and to maintain contact reliability. Actuator Pin plunger Leaf lever Simulated leaf lever Actuator Pin plunger Leaf lever Simulated leaf lever Plunger/lever free From mounting From standoff boss and hole center line >9.2 mm >13.4 mm >10.7 mm >14.9 mm >13.5 mm ■ Environment 1) Although continuous operation of the switch is possible within the range of ambient temperature (humidity), as the humidity range differs depending on the ambient temperature, the humidity range indicated below should be used. Continuous use near the limit of the range should be avoided. 2) This humidity range does not guarantee permanent performance. >17.7 mm Humidity, %R.H. Plunger/Lever pushed From mounting From standoff boss and hole center line 7.8 to 5.9 mm 12.0 to 10.1 mm 8.4 to 6.2 mm 12.6 to 10.4 mm 11.1 to 8.7 mm 15.3 to 12.9 mm 6) PC board terminal type should be used if the products are to be soldered on the PC board. Solder terminal type is not for soldering on PC board. ■ Cautions regarding the circuit 1) In order to prevent malfunction in set devices caused by bounce and chattering during the ON-OFF switch operation, please verify the validity of the circuit under actual operating conditions and temperature range. 2) When switching inductive loads (relays, solenoids, buzzers, etc.), an arc absorbing circuit is recommended to protect the contacts. ■ Please verify under actual conditions. Please be sure to conduct quality verification under actual operating conditions in order to increase reliability during actual use. ■ Selection of switch Please make your selection so that there will be no problems even if the operating characteristics vary up to ±20% from the standard values. ■ Oil-proof and chemical-proof characteristics The rubber cap swells when exposed to oil and chemicals. The extent of swelling will vary widely depending on the type and amount of oil and chemicals. Check with the actual oil or chemicals used. In particular, be aware that solvents such as freon, chlorine, and toluene cannot be used. –9– 95 Acceptable range 50 (Avoid freezing when (Avoid used at temperatures condensation when lower than 0°C) used at temperatures higher than 0°C) 5 –40 0 Temperature, °C +85 ■ Other 1) Please remember that this switch cannot be used under water. Also, please be warned that switching and sudden temperature changes with the presence of water droplets can cause seepage into the switch. 2) Keep away from environments where silicon based adhesives, oil or grease are present as faulty contacts may result from silicon oxide. Do not use in areas where flammable or explosive gases from gasoline and thinner, etc., may be present. 3) When using the lever type, please be careful not to apply unreasonable load from the reverse or lateral directions of operation. 4) Do not exceed the total travel position (TTP) and press the actuator. This could cause operation failure. Also, when switching at high speed or under shock even within the operation limit, the working life may decrease. Therefore, please be sure to verify the quality under actual conditions of use. 5) Please make considerations so that the switch does not become the stopper for the moving part. 6) Please do not pull wire leads constantly. AECTB6E 201408-T
ASQ10328 价格&库存

很抱歉,暂时无法提供与“ASQ10328”相匹配的价格&库存,您可以联系我们找货

免费人工找货