For detection: Seal Type Switches
Turquoise Stroke
Switches
Product Catalog
2022.4
For detection: Seal Type Switches
Turquoise Stroke Switches
Long Stroke and Sliding Contact Construction Sealed Switches
FEATURES
13.3
Long stroke: over travel (OT) is 2.2 mm or more on
the NO side and 2.5 mm or more on the NC side (for
pin plunger type)
Constructed so that the contact force does not
depend on the operation stroke.
High contact reliability to support low level switching
loads.
Highly effective sealing for resistance against
adverse environments
Silent operation with sliding contact
5.4
10.1
TYPICAL APPLICATIONS
Automobiles (detection of door opening and closing
and shift lever position, etc.)
Electric tool and household appliances (vacuum
cleaners, air conditioners, washing machines, etc.
(Unit: mm)
ORDERING INFORMATION (PART NO.)
ASQ1
Size of mounting hole
0: Mounting hole 3 mm
standard type
1: Mounting hole 3 mm
without boss type
4: Right side pin type
(solder terminal only)
5: Left side pin type
(solder terminal only)
6: Right 2 boss type
(solder terminal only)
7: Left 2 boss type
(solder terminal only)
Terminal
3: Wire leads left side type
2: Wire leads right side type
(SPSTNC and SPSTNO only)
(SPSTNC and SPSTNO only)
4: Solder
terminal
5: P/C board 6: Wire leads
terminal
bottom type
Contact form
1: SPDT
2: SPSTNC
(wire lead type only)
COM
N.O. N.C.
COM
N.C.
3: SPSTNO
(wire lead type only)
COM
Actuator
0: Pin plunger
7: Leaf lever
8: Simulated
leaf lever
N.O.
7: P/C board right angle 8: P/C board left angle
terminal
terminal
Note) Not every combination is available. Please refer to the following table,“PRODUCT TYPES”.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー1ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
TYPES
Terminal type
(Mounting hole 3 mm standard type/Mounting hole 3 mm without boss type/2 boss type/Pin fixed side pin type)
Mounting hole 3mm standard type
Actuator
Operating Force
OF (Max.)
Mounting
hole 3 mm Right 2 boss
without boss
type
type
Left 2 boss
type
Pin fixed
right side
pin
Pin fixed left
side pin
Solder
terminal
P/C board
right angle
terminal
P/C board
left angle
terminal
P/C board
bottom
terminal
Solder
terminal
Solder
terminal
Solder
terminal
Solder
terminal
Pin plunger
1.5 N
ASQ10410
ASQ10710
ASQ10810
ASQ11510
ASQ16410
ASQ17410
ASQ14410
ASQ15410
Leaf lever
1.7 N
ASQ10417
ASQ10717
ASQ10817
ASQ11517
ASQ16417
ASQ17417
ASQ14417
ASQ15417
Simulated leaf lever
1.5 N
ASQ10418
ASQ10718
ASQ10818
ASQ11518
ASQ16418
ASQ17418
ASQ14418
ASQ15418
Wire leads bottom type (Mounting hole 3 mm standard type)
Wire leads bottom type (Mounting hole 3 mm standard type)
Operating Force
OF (Max.)
SPDT
SPST-NC
SPST-NO
Pin plunger
1.5 N
ASQ10610
ASQ10620
ASQ10630
Leaf lever
1.7 N
ASQ10617
ASQ10627
ASQ10637
Simulated leaf lever
1.5 N
ASQ10618
ASQ10628
ASQ10638
Actuator
Wire leads side type (Mounting hole 3 mm standard type)
Actuator
Operating Force
OF (Max.)
Wire leads right side type
(Mounting hole 3 mm standard type)
Wire leads left side type
(Mounting hole 3 mm standard type)
SPST-NC
SPST-NO
SPST-NC
SPST-NO
Pin plunger
1.5 N
ASQ10220
ASQ10230
ASQ10320
ASQ10330
Leaf lever
1.7 N
ASQ10227
ASQ10237
ASQ10327
ASQ10337
Simulated leaf lever
1.5 N
ASQ10228
ASQ10238
ASQ10328
ASQ10338
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー2ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
RATING
Contact rating
1 mA 5 V DC to 100 mA 30 V DC
Note: Please consult us regarding 42 V DC rating.
Operation environment and conditions
Item
Specifications
Ambient and storage temperature
–40 to +85°C (no freezing and condensing)
Allowable operating speed
30 to 500 mm/sec
Max. operating cycle rate
120 cpm
Note: When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly depending
on the load capacity. Please consult us.
Electrical characteristics
Dielectric strength (Initial)
Between non-continuous terminals: 600 Vrms.
Between each terminal and other exposed metal parts: 1,500 Vrms.
Between each terminal and ground: 1,500 Vrms. (at detection current of 1 mA)
Insulation resistance (Initial)
Min. 100 MΩ (at 500 V DC insulation resistance meter) (Locations measured same as dielectric strength.)
Contact resistance (Initial)
Max. 1 Ω (by voltage drop 0.1 A 6 to 8 V DC)
Characteristics
Item
Electrical
switching
life
Specifications
5 V DC 1 mA (Resistive load)
Min. 5 × 105 Note 1)
16 V DC 50 mA (Resistive load)
Min. 5 × 105 Note 2)
30 V DC 100 mA (Resistive load)
Min. 2 × 105 Note 2)
Vibration resistance
(malfunction vibration resistance)
Switching frequency: 20 times/min
Conduction ratio: 1:1
Pushbutton operation speed: 100 mm/s
Pushbutton switching position: free position (FP) to operation limit position (TTP)
Single amplitude: 0.75 mm
Amplitude of vibration: 10 to 55 Hz (4 minutes cycle)
Direction and time: 30 minutes each in X, Y and Z directions
Amplitude of vibration: 5 to 200 Hz (10 minutes cycle)
Acceleration: 43.1 m/s2
Direction and time: 30 minutes each in X, Y and Z directions
Shock resistance
(malfunction shock resistance)
Shock value: 980 m/s2
Direction and time: 5 times each in X, Y and Z directions
Vibration resistance endurance
Frequency of vibration: 33.3 Hz,
Acceleration: 43.1 m/s2
Direction and time: 8 hours each in X, Y and Z directions
Terminal strength
6 N min (each direction) *Terminal deformation possible.
Heat resistance
85°C 500 hours
Cold resistance
–40°C 500 hours
Humidity resistance
40°C 95% RH 500 hours
Thermal shock resistance
30 min at 85°C to 30 min at –40°C for 1,000 cycles
Unit weight
Approx. 0.8 g (terminal type), Approx. 5.4 g (wire leads side type)
Protection grade
IP67 (except exposed terminal part of terminal type)
Note: As long as there are no particular designations, the following conditions apply to the test environment.
• Ambient temperature: 5 to 35°C
• Relative humidity: 25 to 85% RH
• Air pressure: 86 to 106 kPa
Note 1: Switching life for single switching (COM-NC or COM-NO connection) and double switching (COM-NC and COM-NO connection).
Note 2: Switching life is for single switching life. For double switching it is min. 105 times.
Protection grade
1) JIS C0920 (water-resistance experiments for electrical
machines and protection rating against incursion of solid
substances): Immersion protected (Note 1)
2) IEC 60529 (rating for outer shell protection): IP67
(Immersion protected) (Note 1)
3) JIS D0203 (method for testing moisture resistance and
water resistance in automotive components): D2 (Note 2)
Note 1) A concrete testing method is to check for any adverse effect on the structure
after leaving it submerged for 30 minutes under 1 m of water (with temperature
difference between water and switch no larger than 5°C).
Note 2) A concrete testing method is to check for any adverse effect on the structure
after leaving it submerged for 10 minutes under 10 cm water (with temperature
difference between water and switch no larger than 30°C).
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー3ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
Operating characteristics*Note 1
Characteristics
Operating Force (OF) Max. *Note 2
Total travel Force (TF) Max. (reference value)
Free Position (FP) Max.
Pin plunger
Leaf lever
1.5 N
1.7 N
Simulated leaf lever
1.5 N
(2.0 N)
(3.1 N)
(2.8 N)
14.4 mm
From mounting boss and hole center line
9.2 mm
11.5 mm
From standoff
13.4 mm
15.7 mm
18.6 mm
8.7±0.3 mm
9.8±0.5 mm
12.5±0.5 mm
12.9±0.3 mm
Operating Position on N.C. side From mounting boss and hole center line
(OP (N.C.) ) *Note 3, 5
From standoff
14.0±0.5 mm
16.7±0.5 mm
Operating Position on N.O. side From mounting boss and hole center line
(OP (N.O.) ) *Note 4, 5
From standoff
8.4±0.3 mm
9.3±0.5 mm
12.0±0.5 mm
12.6±0.3 mm
13.5±0.5 mm
16.2±0.5 mm
From mounting boss and hole center line
8.8±0.3 mm
10.1±0.5 mm
12.9±0.5 mm
From standoff
13.0±0.3 mm
14.3±0.5 mm
17.1±0.5 mm
From mounting boss and hole center line
8.5±0.3 mm
9.6±0.5 mm
12.4±0.5 mm
From standoff
12.7±0.3 mm
13.8±0.5 mm
16.6±0.5 mm
Over travel on N.C. side (OT (N.C.) ) Min.
2.5 mm
3.1 mm
3.3 mm
Over travel on N.O. side (OT (N.O.) ) Min.
2.2 mm
2.6 mm
2.8 mm
From mounting boss and hole center line
(5.9 mm)
(6.2 mm)
(8.7 mm)
From standoff
(10.1 mm)
(10.4 mm)
(12.9 mm)
Release Position on N.C. side
(RP (N.C.) ) *Note 6
Release Position on N.O. side
(RP (N.O.) ) *Note 7
Total Travel Position (TTP)
(reference value)
Notes: 1. The above indicates the characteristics when operating the pushbutton from the vertical direction.
2. Indicates operation load for N.O. contact to achieve ON status.
3. Indicates position for N.C. contact to achieve OFF status.
4. Indicates position for N.O. contact to achieve ON status.
5. Although there is some overlap in the range of the operating position (OP) on the N.C. and N.O. sides due to the tolerance, in actuality there is always an intermediate OFF
range (the N.C. and N.O. sides will never ON at the same time.)
6. Indicates position for N.C. contact to achieve ON status.
7. Indicates position for N.O. contact to achieve OFF status.
OPERATION CONCEPT DIAGRAM
Standard ( mounting boss and
hole center diameter or standoff )
Contact form: SPDT
Operation load
Operation
load
TF
OF
RF
0
RP (N.C.)
N.C. side
Contact force
OT (N.C.)
OP (N.C.)
0
(OFF)
Stroke
N.O. side
OT (N.O.)
RP (N.O.)
Range of possible use
TTP
OP (N.O.)
FP
N.C. side
N.O. side
DATA
Applicable current range (Reference)
100 mA
Applicable range
1 mA
0
DC 5 V
30 V
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー4ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
DIMENSIONS
Unit: mm
CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website.
Terminal type: Mounting hole 3 mm, standard type Pin plunger
External dimensions
CAD
C0.3
8.4±0.2
5.4±0.15
φ1.9
5.1
5.9
4.2
8.3±0.1
3.7
3.0+0.1
-0
TTP(5.9)
3.2±0.1
TTP(10.1)
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
RP(N.O.)12.7±0.3
OP(N.O.)12.6±0.3
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
FP Max. 9.2
RP(N.C.)13.0±0.3
OP(N.C.)12.9±0.3
FP Max. 13.4
13.3±0.15
5.4
2.7
4.53±0.15
3.0+0.3
-0.2
4.53±0.15
1.5
1.2
2.0
0.4
φ3.0+0
-0.1
0.4
4.1
General tolerance: ±0.25
Operating Force (OF) Max.
1.5 N
Total travel Force (TF) Max.
(reference value)
(2.0 N)
Free Position
(FP) Max.
From mounting boss
and hole center line
9.2 mm
From standoff
13.4 mm
From mounting boss
Operating
Position on N.C. and hole center line
side (OP (N.C.) ) From standoff
From mounting boss
Operating
Position on N.O. and hole center line
side (OP (N.O.) ) From standoff
Release Position From mounting boss
and hole center line
on N.C. side
(RP (N.C.) )
From standoff
Release Position From mounting boss
and hole center line
on N.O. side
(RP (N.O.) )
From standoff
8.4±0.3 mm
12.6±0.3 mm
8.8±0.3 mm
13.0±0.3 mm
8.5±0.3 mm
12.7±0.3 mm
2.5 mm
Over travel on N.O. side (OT (N.O.) ) Min.
2.2 mm
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
ー5ー
12.9±0.3 mm
Over travel on N.C. side (OT (N.C.) ) Min.
From mounting boss
Total Travel
and hole center line
Position (TTP)
(reference value) From standoff
industrial.panasonic.com/ac/e/
8.7±0.3 mm
Panasonic Industry Co., Ltd. 2022
(5.9 mm)
(10.1 mm)
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
Terminal type: Leaf lever
External dimensions
CAD
C0.3
13.3±0.15
5.4
2.7
φ1.9
14.
(1
8.4±0.2
5.4±0.15
3.3
0.5
5.1
5.9
3.7
4.2
3.2±0.1
3.0+0.1
-0
1.2
TTP(6.2)
TTP(10.4)
RP(N.O.)9.6±0.5
OP(N.O.)9.3±0.5
RP(N.O.)13.8±0.5
OP(N.O.)13.5±0.5
RP(N.C.)10.1±0.5
OP(N.C.)9.8±0.5
FP Max. 11.5
RP(N.C.)14.3±0.5
OP(N.C.)14.0±0.5
FP Max. 15.7
0
)
8°
8.3±0.1
4.53±0.15
4.53±0.15
3.0+0.3
-0.2
1.2
2.0
1.5
0.4
φ3.0+0
-0.1
0.4
4.1
General tolerance: ±0.25
Note) When switching at high speed or under shock, lever endurance may drop.
Therefore, please be sure to conduct an endurance evaluation under actual switching conditions.
Operating Force (OF) Max.
1.7 N
Total travel Force (TF) Max.
(reference value)
(3.1 N)
Free Position
(FP) Max.
From mounting boss
and hole center line
11.5 mm
From standoff
15.7 mm
From mounting boss
and hole center line
Operating
Position on N.C.
side (OP (N.C.) ) From standoff
14.0±0.5 mm
From mounting boss
Operating
Position on N.O. and hole center line
side (OP (N.O.) ) From standoff
Release Position From mounting boss
and hole center line
on N.C. side
(RP (N.C.) )
From standoff
Release Position From mounting boss
and hole center line
on N.O. side
(RP (N.O.) )
From standoff
13.5±0.5 mm
10.1±0.5 mm
14.3±0.5 mm
9. 6±0.5 mm
13.8±0.5 mm
3.1 mm
Over travel on N.O. side (OT (N.O.) ) Min.
2.6 mm
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
ー6ー
9.3±0.5 mm
Over travel on N.C. side (OT (N.C.) ) Min.
From mounting boss
Total Travel
and hole center line
Position (TTP)
(reference value) From standoff
industrial.panasonic.com/ac/e/
9.8±0.5 mm
Panasonic Industry Co., Ltd. 2022
(6.2 mm)
(10.4 mm)
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
Terminal type: Simulated leaf lever
External dimensions
CAD
C0.3
13.3±0.15
5.4
2.7
φ1.9
8.4±0.2
5.4±0.15
3.3
0.5
1.2
2.0
4.53±0.15
1.5
0.4
8.3±0.1
4.53±0.15
5.1
5.9
3.0+0.3
-0.2
φ3.0+0
-0.1
3.7
4.2
3.2±0.1
3.0+0.1
-0
TTP(8.7)
1.2
(1
8°
)
0
TTP(12.9)
RP(N.O.)12.4±0.5
OP(N.O.)12.0±0.5
15.
RP(N.O.)16.6±0.5
OP(N.O.)16.2±0.5
RP(N.C.)12.9±0.5
OP(N.C.)12.5±0.5
FP Max. 18.6
FP Max. 14.4
RP(N.C.)17.1±0.5
OP(N.C.)16.7±0.5
2.8
R2.0
0.4
4.1
General tolerance: ±0.25
Note) When switching at high speed or under shock, lever endurance may drop.
Therefore, please be sure to conduct an endurance evaluation under actual switching conditions.
Operating Force (OF) Max.
1.5 N
Total travel Force (TF) Max.
(reference value)
(2.8 N)
Free Position
(FP) Max.
From mounting boss
and hole center line
14.4 mm
From standoff
18.6 mm
From mounting boss
and hole center line
Operating
Position on N.C.
side (OP (N.C.) ) From standoff
16.7±0.5 mm
From mounting boss
Operating
Position on N.O. and hole center line
side (OP (N.O.) ) From standoff
Release Position From mounting boss
and hole center line
on N.C. side
(RP (N.C.) )
From standoff
Release Position From mounting boss
and hole center line
on N.O. side
(RP (N.O.) )
From standoff
16.2±0.5 mm
12.9±0.5 mm
17.1±0.5 mm
12.4±0.5 mm
16.6±0.5 mm
3.3 mm
Over travel on N.O. side (OT (N.O.) ) Min.
2.8 mm
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
ー7ー
12.0±0.5 mm
Over travel on N.C. side (OT (N.C.) ) Min.
From mounting boss
Total Travel
and hole center line
Position (TTP)
(reference value) From standoff
industrial.panasonic.com/ac/e/
12.5±0.5 mm
Panasonic Industry Co., Ltd. 2022
(8.7 mm)
(12.9 mm)
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
P/C board terminal: Mounting hole 3 mm without boss type
C0.2
3.0+0.3
-0.2
P/C board terminal
CAD
0.9
5.08±0.15 5.08±0.15
General tolerance: ±0.25
P/C board pattern
φ1.0+0.1
-0
5.08±0.1 5.08±0.1
Terminal type: Right side pin type
External dimensions
CAD
8.3
2.6±0.05
φ2.2±0.05
C0.2
8.3±0.1
5.9
3.7
4.2
3.0+0.3
-0.2
4.53±0.15
4.53±0.15
2.6±0.05
φ1.9
1.5
0.4
1.2
2.0
5.0
5.4±0.15
5.1
TTP(5.9)
TTP(10.1)
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
RP(N.O.)12.7±0.3
OP(N.O.)12.6±0.3
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
FP Max. 9.2
RP(N.C.)13.0±0.3
OP(N.C.)12.9±0.3
FP Max. 13.4
13.3±0.15
5.4
2.7
4.1
0.4
General tolerance: ±0.25
Terminal type: Left side pin type
External dimensions
CAD
8.3±0.1
φ2.2±0.05
2.6±0.05
C0.2
8.3
5.0
4.2
3.0+0.3
-0.2
4.53±0.15
2.6±0.05
5.9
3.7
4.53±0.15
1.5
0.4
1.2
2.0
5.4±0.15
φ1.9
5.1
TTP(5.9)
TTP(10.1)
RP(N.O.)8.5±0.3
OP(N.O)8.4±0.3
RP(N.O.)12.7±0.3
OP(N.O.)12.6±0.3
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
RP(N.C.)13.0±0.3
OP(N.C.)12.9±0.3
FP Max. 13.4
FP Max. 9.2
13.3±0.15
5.4
2.7
4.1
0.4
General tolerance: ±0.25
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー8ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
Terminal type: Right 2 boss type
External dimensions
CAD
8.3±0.1
C0.3
φ23.0+0
-0.1
13.3±0.15
5.4±0.15
5.1
3.7
4.2
1.5
3.0+0.3
-0.2
4.53 ±0.15
0.4
1.2
2.0
4.53 ±0.15
1.5
5.9
φ1.9
TTP(5.9)
TTP(10.1)
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
RP(N.O.)12.7±0.3
OP(N.O.)12.6±0.3
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
RP(N.C.)13.0±0.3
OP(N.C.)12.9±0.3
FP Max. 13.4
FP Max. 9.2
5.4
2.7
4.1
0.4
General tolerance: ±0.25
Terminal type: Left 2 boss type
External dimensions
CAD
C0.3
1.5
5.9
5.1
φ1.9
3.7
8.3±0.1
5.4±0.15
4.2
TTP(5.9)
TTP(10.1)
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
RP(N.O.)12.7±0.3
OP(N.O.)12.6±0.3
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
RP(N.C.)13.0±0.3
OP(N.C.)12.9±0.3
FP Max. 13.4
FP Max. 9.2
13.3±0.15
5.4
2.7
4.53±0.15
3.0+0.3
-0.2
1.2
2.0
1.5
0.4
φ23.0+0
-0.1
4.53±0.15
4.1
0.4
General tolerance: ±0.25
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー9ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
Angle terminal type: Mounting hole 3 mm, standard type (Right type)
External dimensions
CAD
C0.2
COM
5.08±0.15 5.08±0.15
0.9
N.O.
N.C.
C0.3
8.4±0.2
5.4±0.15
φ1.9
13.3±0.15
6.0±0.3
8.3±0.1
2.0
4.1
3.1±0.4
0.4
3.7
4.2
3.0+0.1
-0
φ3.0+0
-0.1
5.1
5.9
3.2±0.1
TTP(5.9)
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
FP Max. 9.2
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
5.4
2.7
General tolerance: ±0.25
Angle terminal type: Mounting hole 3 mm, standard type (Left type)
External dimensions
CAD
C0.3
COM
C0.2
N.O.
0.9
N.C.
5.08±0.15 5.08±0.15
8.4±0.2
5.4±0.15
φ1.9
3.2±0.1
2.0
6.0±0.3
8.3±0.1
0.4
3.7
4.2
φ3.0+0
-0.1
3.0+0.1
-0
5.1
5.9
TTP(5.9)
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
FP Max. 9.2
13.3±0.15
5.4
2.7
4.1
3.1±0.4
General tolerance: ±0.25
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 10 ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
Wire leads bottom type: Mounting hole 3 mm, standard type
External dimensions
CAD
C0.3
8.4±0.2
5.4±0.15
13.3±0.15
φ1.9
3.0+0.1
-0
5.1
3.7
φ3.0+0
-0.1
5.9
3.2±0.1
TTP(5.9)
4.3
8.3±0.1
3.2
4.2
R0.3
2.2
R0.2
3.6
5.0±2
2.6
φ1.4
300±10
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
FP Max. 9.2
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
5.4
2.7
Wire lead thickness: 0.3 mm2
Wire lead color
: COM…Black
N.O. …White
N.C. …Red
General tolerance: ±0.25
Wire leads right side type: Mounting hole 3 mm, standard type
External dimensions
CAD
R0.5
C0.3
8.4±0.2
5.4±0.15
13.3±0.15
φ1.9
R2.0
5.0±2
R0.5
2.4
300±10
R0.5
4.5
4.3
φ1.4
3.0+0.1
-0
8.3±0.1
3.7
φ3.0+0
-0.1
5.1
5.9
3.2±0.1
TTP(5.9)
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
FP Max. 9.2
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
5.4
2.7
Wire lead thickness: 0.3 mm2
Wire lead color
: COM…Black
N.O. …White
N.C. …Red
General tolerance: ±0.25
5.2
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 11 ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
Wire leads left side type: Mounting hole 3 mm, standard type
External dimensions
CAD
R0.5
C0.3
8.4±0.2
5.4±0.15
5.4
2.7
5.2
5.9
5.1
3.7
φ3.0+0
-0.1
3.0+0.1
-0
TTP(5.9)
RP(N.O.)8.5±0.3
OP(N.O.)8.4±0.3
FP Max. 9.2
3.2±0.1
8.3±0.1
4.3
4.5
φ1.4
R0.5
RP(N.C.)8.8±0.3
OP(N.C.)8.7±0.3
φ1.9
13.3±0.15
5.0±2 R0.5
300±10
2.4
Wire lead thickness: 0.3 mm2
Wire lead color
: COM…Black
N.O. …White
N.C. …Red
General tolerance: ±0.25
R2.0
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 12 ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
GUIDELINES FOR USAGE
Soldering conditions
Cautions regarding the circuit
The application of excessive heat upon the switch when
soldering can cause degradation of switch operation.
Therefore, be sure to keep within the conditions given below.
Manual soldering: use soldering irons (max. 350°C, within 3
seconds at each terminal) capable of temperature adjustment.
This is to prevent deterioration due to soldering heat. Care
should be taken not to apply force to the terminals during
soldering.
(More than one second interval is required to apply heat
at each terminal.) Please consult us if you intend to use a
soldering iron that exceeds 60 W.
1) In order to prevent malfunction in set devices caused by
bounce and chattering during the ON-OFF switch operation,
please verify the validity of the circuit under actual operating
conditions and temperature range.
2) When switching inductive loads (relays, solenoids, buzzers,
etc.), an arc absorbing circuit is recommended to protect
the contacts.
Mounting
Please avoid use in which load would be applied to the sides
(hatch part (both sides) shown below) of the switch in the
direction indicated by the arrows. This could cause erroneous
operation. Also, when using a metal installation board, please
make allowance for burr direction designation and burr
suppressing, etc., so that the burr side will not be on the switch
installation side.
1) To secure the switch, please use an M3 small screw on a
flat surface and tighten using a maximum torque of 0.29
N·m. It is recommended that both flat metal washer and
spring washers be used with the screws and adhesive
be applied to lock the screws to prevent loosening of the
screws. Please make sure not to apply adhesive onto the
moving parts.
2) Be sure to maintain adequate insulating clearance between
each terminal and ground.
3) Although it is possible to directly operate the pin plunger
type from the lateral direction, please consult us if doing so.
4) After mounting please make sure no tensile load will be
applied to the switch terminals.
5) Range of possible use: Please set the operation position
to within the ranges in the following table so that there
is sufficient insulation distance and to maintain contact
reliability.
Plunger/lever free
From
mounting
boss and
hole center
line
From
standoff
Pin plunger
>9.2 mm
Leaf lever
Simulated
leaf lever
Actuator
Plunger/Lever pushed
Please verify under actual conditions.
Please be sure to conduct quality verification under actual
operating conditions in order to increase reliability during
actual use.
Selection of switch
Please make your selection so that there will be no problems
even if the operating characteristics vary up to ±20% from the
standard values.
Oil-proof and chemical-proof characteristics
Do not use alcohol-based solvents.
The rubber cap swells when exposed to oil and chemicals.
The extent of swelling will vary widely depending on the type
and amount of oil and chemicals.
Check with the actual oil or chemicals used. In particular,
be aware that solvents such as freon, chlorine, toluene, and
cannot be used.
Environment
1) Although continuous operation of the switch is possible
within the range of ambient temperature (humidity), as
the humidity range differs depending on the ambient
temperature, the humidity range indicated below should be
used. Continuous use near the limit of the range should be
avoided.
2) This humidity range does not guarantee permanent
performance.
Humidity (% RH)
95
Allowable range
Avoid con
densation when
used at tem
peratures higher
than 0°C
Avoid icing
when used at
temperatures
lower than 0°C
From
mounting
boss and
hole center
line
From
standoff
>13.4 mm
7.8 to 5.9
mm
12.0 to 10.1
mm
>10.7 mm
>14.9 mm
8.4 to 6.2
mm
12.6 to 10.4
mm
>13.5 mm
>17.7 mm
11.1 to 8.7
mm
15.3 to 12.9
mm
5
40
0
40
Ambient temperature (℃)
85
6) P/C board terminal type should be used if the products are
to be soldered on the P/C board. Solder terminal type is not
for soldering on P/C board.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 13 ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Turquoise Stroke Switches (ASQ1)
Other
Be careful when handling the switch to make sure that the
rubber cap for sealing the plunger does not break.
1) Please remember that this switch cannot be used under
water. Also, please be warned that switching and sudden
temperature changes with the presence of water droplets
can cause seepage into the switch.
2) Keep away from environments where silicon based
adhesives, oil or grease are present as faulty contacts
may result from silicon oxide. Do not use in areas where
flammable or explosive gases from gasoline and thinner,
etc., may be present.
3) When using the lever type, please be careful not to apply
unreasonable load from the reverse or lateral directions of
operation.
4) Do not exceed the total travel position (TTP) and press the
actuator. This could cause operation failure. Also, when
switching at high speed or under shock even within the
operation limit, the working life may decrease. Therefore,
please be sure to verify the quality under actual conditions
of use.
5) Please make considerations so that the switch does not
become the stopper for the moving part.
6) On the lead wire routing, do not allow any continuous
pulling load.
Please refer to "the latest product specifications"
when designing your product.
•Requests to customers:
https://industrial.panasonic.com/ac/e/salespolicies/
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 14 ー
Panasonic Industry Co., Ltd. 2022
AECTB6E 202204
Notes for Turquoise Switches (BJ, BS, BV type)
CAUTIONS FOR USE (Common for BJ, BS and BV types)
Fastening of the switch body
1) Fasten the switch body onto a smooth surface using the correct
screw as shown in the chart below and tighten it with the prescribed
torque.
The switch case may deform depending on the type of screw (screw
head diameter, etc.), the size of the washer, and the use or non-use
of a washer. Therefore, please confirm the appropriate torque of
actual conditions. Also, it is recommended that adhesive be applied
to lock the screws to prevent loosening of the screws. When doing
so, please be careful not let any adhesive get inside the switch.
Screws
Tightening torque
M1.2
Not more than 0.098 N·m
ABJ (BJ) switches
M2.3
Not more than 0.29 N·m
M3.0
Not more than 0.29 N·m
ABS (BS) switches
M2.3
Not more than 0.29 N·m
ABV (BV) switches
M3.0
Not more than 0.49 N·m
2) Fixed pin type
To secure the switch unit, thermally crimp or press-fit the mounting
pins. If the pins are to be press-fitted, install a guide on the opposite
surface to the mounting pins to prevent them from slipping out of
position and developing play.
3) Be sure to maintain adequate insulating clearance between each
terminal and ground.
4) The positioning of the switch should be such that direct force is not
applied to the pushbutton or actuator in its free position.
The operating force to the pushbutton should only be applied in a
perpendicular direction.
5) The standard value of overtravel used should be within the range of
70% to 100% of the rated OT value.
6) When soldering the BV type turquoise switch or the immersion
protected type of the BJ and BS type switches, the sealing material
sometimes forms a lump or bulge at the base of the terminal or
lead. Be sure to allow enough space for this when attaching the
switch.
Soldering operations
1) Manual soldering: Perform soldering in less than 3 seconds with
maximum 350 C iron. Care should be taken not to apply force to the
terminals during soldering. We recommend a soldering iron with
temperature adjustment in order to prevent poor quality soldering.
Please consult us if you intend to use a soldering iron of 60 W or
higher.
2) Terminal portions should not be moved within 1 minute after
soldering.
Soldering time
ABJ (BJ) switches
Within 3 seconds
ABS (BS) switches
Within 3 seconds
ABV (BV) switches
Within 5 seconds
Cautions regarding use
1) When switching inductive loads (relays, solenoids, buzzers,
etc.), an arc absorbing circuit is recommended to protect the
contacts.
2) If switching of the contact is synchronized with the phase of the AC
power, reduced electrical life or welded contact may occur.
Therefore, test the switch while it is operating under actual loads for
this condition. If found, you may wish to take corrective action in
your design.
3) In the slow or high speed operating condition, the electrical life
might be greatly reduced depending upon the switching load.
Please consult us before use.
4) Using lever type in do not condition, there is the concern that the
flexible part may be impeded and return movement may not be
possible. In this situation take the following precautions:
• Select a product of higher OF or use a leaf type lever.
• Attach a protective cover to the lever.
5) If the leaf lever type switch is excessively pushed (pushed further
than the operational limit position) or switching is done at high
speed or is accompanied by the impact, the lever will break.
Please be careful. Also, be careful with the short roller lever type
ABV (BV) switch as improper return may result from pressing too
much.
Protection from dust, water and corrosive gas
1) The pin button and the space around the body cap Turquoise
switches are sealed with elastic material, the terminal portion is
integrally molded. This prevents dust entry and protects the switch
against corrosive gases. Wireleaded types are recommended for
applications subject to water or oil splash.
However, avoid soaking these immersion protected types in oil or
water, because those types are not of completely oil tight
construction.
2) Switch operation or rapid temperature change while water droplets
are on the switch may cause the water invasion inside the switch
because of breathing action on condensation.
Especially do not use switch in a bath.
If sources of silicon gas are existing in the vicinity of the switch
(silicon rubber, silicon oil, silicon coating, and silicon filler, etc.),
silicon gas (low molecular siloxane, etc.) will be emitted and it will
get into the product due to the permeability of the plastic.
If the switch is used or stored in such an environment, silicon
compound might generate on the contacts, cause the and faulty
contacting. Therefore, please do not use sources that can emit
silicon gas in the vicinity of the switch.
Do not use in areas where flammable or explosive gases from
gasoline and thinner, etc., may be present.
Selection of the switch
Allow for up to 20% variation of the specified characteristics values
to compensate for long term operational wear of the switch in your
design.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 15 ー
Panasonic Industry Co., Ltd. 2022
AECTB35E 202204
Notes for Turquoise Switches (BJ, BS, BV type)
ㅡ Hydrogen sulfide exposure test
Test conditions: Concentration: 3 ppm, Temperature: 40 °C,
Humidity: 75% RH
1Ω
100 mΩ
10 mΩ
100 Ω
Typical products
10 Ω
1Ω
100 mΩ
Turquoise switches
10 mΩ
0
Standard
value 8 hours
100
200
300
400
500
Elapsed time (h)
Oil-proof and chemical-proof characteristics
2
4
6
The rubber elastomer swells when exposed to oil and chemicals.
The extent of swelling will vary widely depending on the type and
amount of oil and chemicals.
Check with the actual oil or chemicals used.
In particular, be aware that solvents such as freon, chlorine, and
toluene cannot be used.
8 10 12 14 16 18 20 22 24
Elapsed time (h)
ㅡ Waterproof test
Test conditions: Immersion protected IP67 switches ...
Submerge at 1 m below the water surface for 30 minutes.
Insulation resistance (MΩ)
Contact resistance
Contact resistance
ㅡ Dust protection test
Test conditions: The talcum powder used shall be able to pass
through a square- meshed sieve the nominal wire
diameter of 7 μm. The amount of talcum powder to
be used is 2 kg per cubic metre of the test chamber
volume. The duration of the test is 8 hours.
No damage observed after the test.
Washability [ABJ (BJ) and ABS (BS)]
Do not clean the switch. Doing so can cause problems.
Please contact us if cleaning is necessary.
1000
100
10
Standard value
30 minutes
2
4
6
8 10 12 14 16 18 20 22 24
Elapsed time (h)
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 16 ー
Panasonic Industry Co., Ltd. 2022
AECTB35E 202204
Notes for Turquoise Switches (BJ, BS, BV type)
REFERENCE
Dust-protected type
This type of construction prevents dust that is large enough to
have an effect on operation from getting inside the unit. This
construction is stipulated by protective classes against solid matter
in the IEC standards (IEC60529).
The talcum powder used shall be able to pass through a
squaremeshed sieve the nominal wire diameter of 7 μm. The
amount of talcum powder to be used is 2 kg per cubic metre of the
test chamber volume. The duration of the test is 8 hours.
No damage observed after the test.
of protection indicated by the 1st Characteristics number
ㅡLevel
1st
Characteristics
number
Immersion-protected type
This type of construction prevents any harmful effects even after the
device is left underwater at a depth of 1 m for 30 minutes.
This construction is stipulated by protective classes against water in
the IEC standards (IEC60529).
IEC’s IP Codes
0
No protection
1
Protected against solid matter larger than 50 mm
2
Protected against solid matter larger than 12 mm
3
Protected against solid matter larger than 2.5 mm
4
Protected against solid matter larger than 1.0 mm
5
Dust-protected type
Prevents dust that is large enough to have an effect
on operation from getting inside the unit
6
Dust-resistant type
Prevents dust from getting inside the unit
ㅡ Level of protection indicated by the 2nd Characteristics number
The IEC (International Electrotechnical Commission) has defined
the IP characteristic code that represents the levels of protection
described in IEC standard (IEC60529).
The two numbers that follow the IP code (the characteristics
numbers) indicate the suitability of this protection for all
environmental conditions.
1st characteristics number
Protection level (IEC60529/Solid matter)
JIS C 0920
IP
2nd characteristics number
2nd
Characteristics Protection level (IEC60529/Liquid matter)
number
0
No protection
Droplet-protected
type I
1
Protected against water droplets that
fall perpendicular to the unit
Droplet-protected
type II
2
Protected against water droplets that
fall from within 15° of perpendicular
to the unit
Rain-protected
type
3
Protected against water droplets that
fall from within 60° of perpendicular
to the unit
Splash-protected
type
4
Protected against water that
splashes on the unit from any
direction
Spray-protected
type
5
Free from adverse effects even if
sprayed directly with water from any
direction
Water-resistant
type
6
Protected against water sprayed
directly on the unit from any direction
Immersionprotected type
7
Water does not get inside of the unit
when submerged in water according
to the specified conditions
Underwater type
8
Unit can be used underwater
Note: Details of test conditions are the same as NECA C 0920.
Please refer to them.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー 17 ー
Panasonic Industry Co., Ltd. 2022
AECTB35E 202204
Electromechanical Control Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industral.panasonic.com/ac/e/
©Panasonic Industry Co., Ltd. 2022
Specifications are subject to change without notice.
AECTB6E 202204
2022.4