AQ-A *(AQAD)
VDE
Small Screw Terminal SSR
Ideal for DC Control
AQ-A RELAYS
(DC only)
FEATURES
TYPICAL APPLICATIONS
1. Compact Size
W 40 L 58 H 25.5 mm
W 1.575 L 2.283 H 1.004 inch
2. With terminal cover for safety
(output side only).
• Photovoltaic power generation
system
• Storage battery system
• For control of all types of business
equipment and industrial use DC
heaters/motors, etc.
*
Cover on input side available as option.
3. Mounting pitch 47.5 mm 1.870 inch
4. Internal diode protects element on
output side
5. With LED indication for operation
status verification
* Please visit our website to find out the latest about
international standards compliance.
ORDERING INFORMATION
AQAD
Output current
1: 10A
5: 30A
Load voltage, Type
5: 100 V DC, Screw terminal and DC only
7: 600 V DC, Screw terminal and DC only
Input voltage
1: 4 to 32 V DC
Functions
DL: Internal diode and LED indication
TYPES
1. AQ-A Solid State Relays (DC only)
Type
DC only
Load current
30A
10A
Load voltage
100V DC
600V DC
Input voltage
Part No.
4 to 32V DC
AQAD551DL
AQAD171DL
Standard Packing; carton: 2 pcs., case: 60 pcs.
2. Accessories
Type
Standard heat sink
Slim heat sink (45mm 1.772inch wide)
(Mountable on a DIN rail)
DIN rail mounting plate
Terminal cover
Mounting rail
Fastening plate
ds_61651_en_aqad: 120713J
Part No.
AQP-HS-J25A
AQP-HS-SJ20A
AQP-DPJ
AQA801
AT8-DLA1
ATA4806
Packaged quantity
No carton, 5 in a case
No carton, 8 in a case
No carton, 50 in a case
No carton, 50 in a case
1 in a carton, 100 in a case
1 in a carton, 200 in a case
1
AQ-A (AQAD)
RATING
1. Ratings (Measurement condition: at 20C 68F, Input ripple: 1% or less)
Item
Input side
Output side
Part No.
Input voltage
Input current
Drop-out voltage
Max. load current (DC)
Peak load current
Load voltage (DC)
“OFF-state” leakage current
“ON” resistance
Max. power dissipation
AQAD551DL
AQAD171DL
Remarks
4 to 32V DC
Max. 20mA
Min. 1V
30A
90A (VL = 60V DC)
100V
10A
20A (VL = 600V DC)
600V
Max. 100A
Max. 20m
Max. 200m
100 ms (1 shot)
Absolute maximum rating
VL = Max.
at Max. carrying current
20W
2. Characteristics (Measurement condition: at 20C 68F, Input ripple: 1% or less)
Item
AQAD551DL
AQAD171DL
Max. 10ms
Max. 5ms
Max. 3ms
Max. 1ms
100M between input and output
4,000 Vrms between input and output
2,500 Vrms between input, output and case
10 to 55Hz double amplitude of 1.5mm .059inch
Min. 980 m/s2
–20C to +80C –4F to +176F
–20C to +85C –4F to +185F
0.5 times/s
Operate time
Release time
Insulation resistance
Breakdown voltage
Vibration resistance
Shock resistance
Ambient temperature
Storage temperature
Max. switching frequency
Remarks
Vin = 4 V, IL = 1 A, VL = 10 V Resistance load
Vin = 4 V, IL = 1 A, VL = 10 V Resistance load
at 500V DC
for 1min.
X, Y, Z axes
X, Y, Z axes
Non-condensing at low temperatures
Non-condensing at low temperatures
Vin = 4 V, duty = 50%, IL = Max., VL = Max.
Note: Vin is input voltage, IL is load current, and VL is load voltage.
REFERENCE DATA
1. Load current vs. ambient temperature characteristics
Use load current within range specified in the figure below.
Tested condition
With external heat sink
If the mounting surface is not metallic and a heat sink
is not used, expose the bottom surface and plate
surface to improve heat dissipation.
(2) 10A type (AQAD171DL)
40
15
When using slim heat sink
32 (AQP-HS-SJ20A)
12
24
Load current, A
Without external heat sink
Load current, A
(1) 30A type (AQAD551DL)
When using standard heat sink (AQP-HS-J25A) or
slim heat sink (AQP-HS-SJ20A)
1) If attached to a heat sink, use a heat conductive
compound (Ex. Momentive Performance Materials
Inc. YG6111 or TSK5303) of similar coating to
improve cooling.
When using as stand-alone
16
8
0
+32
0
20
40
60
80
100
+32 +68 +104 +140 +176 +212
Ambient temperature, °C °F
3. Input current vs. input voltage characteristics
6
5
4
3
2
20
9
8
Input current, mA
7
Duty = 50%
10
Max. switching frequency, time/s
Max. switching frequency, time/s
8
1
7
6
5
4
16
12
8
3
2
4
1
750
1500
2250
3000
Load voltage, V × load current, A
2
When using as stand-alone
Ambient temperature: 20C 68F
Duty = 50%
9
0
6
0
-30 -20
-22 -4
20
40
60
80
100
+68 +104 +140 +176 +212
Ambient temperature, °C °F
2. Max. switching frequency vs. load voltage load current characteristics
(1) 30A type (AQAD551DL)
(2) 10A type (AQAD171DL)
10
9 When using slim heat
sink (AQP-HS-SJ20A)
3
0
-20
-4
Ambient temperature: 20C 68F
When using standard heat
sink (AQP-HS-J25A)
0
1500
3000
4500
6000
Load voltage, V × load current, A
0
0
5
10
15
20
25
30
35
Input voltage, V
ds_61651_en_aqad: 120713J
AQ-A (AQAD)
DIMENSIONS (mm inch)
CAD Data
Data from our Web site.
Download CAD
External dimensions
CAD Data
Schematic
40
1.575
−
+
4
.1 .3 d
69 ia.
dia
.
2-M4
Input power
source
4
1
3
2
Load
IL
Load
58
2.283
47.5
1.870
AQAD551DL
MADE IN JAPAN
−
INPUT
4-32VDC
2-M3
−
+
+
2
LOAD
30A 100VDC
4
−
+
Load power
source
IL
−
1
Load power
source
3
+
Mounting dimensions
Lot No.
47.5+0.2
−0.1
1.870+.008
−.004
2-4.3 dia. or M4
2-.069 dia. or M4
4.3
.169
25.5
1.004
(15.5)
(.610)
(3)
(.118)
10.5
.413
(10.5)
(.413)
General tolerance: 1.0.039
ACCESSORIES (mm inch)
CAD Data
Data from our Web site.
Download CAD
AQP-HS-SJ20A Slim Heat Sink
External dimensions
CAD Data
100
90
78
40
Mounting dimensions
2-4.6 dia. or M4
2-.181 dia. or M4
3.937
3.543
3.071
1.575
7-M4
(Effective screw depth: 6mm .236inch)
6
30
.236 1.181
4.6 dia.
.181 dia.
47.6 1.874
30
1.181
6
.236
90±0.2
3.543±.008
4.6x5.6 elliptical hole
.181x.220
45 1.772
78
83
3.071 3.268
1.6
.063
“A” part
General tolerance: 1.0.039
Note: When using on a DIN rail, please install so that the “A” part is on top.
ds_61651_en_aqad: 120713J
3
AQ-A (AQAD)
AQP-HS-J25A Standard Heat Sink
External dimensions
CAD Data
Mounting dimensions
4-M4.5 or 5 dia.
4-M4.5 or .197 dia.
4-R2.5 .098
3-
M
4
5
.197
30
1.181
47.5 119
150
1.870 4.685 5.906
132
5.197
119±0.1
4.685±.004
132±0.1
5.197±.004
2
.079
7
.276
52
2.047
3
.118
46
64
82
100
120
142
1.811
2.520
3.228
3.937
4.724
5.591
AQP-DPJ DIN Rail Mounting Plate
CAD Data
External dimensions
13
.512
General tolerance: 1.0.039
AT8-DLA1 Mounting Rail
CAD Data
4.6 dia.
.181 dia.
1.6
.063
3-M4
47.6
90 1.874
30
3.543
1.181 19
.748
12.1
.476
16.5
.650
4.6x5.6 elliptical hole
.181x.220
15
.591
100
3.937
1,000±0.1
39.37±.004
6
.236
5.5
.217
5
.197
15 10 15
.591 .394 .591
2.75R 15 10 15
.108R .591 .394 .591
40-5.5x15 slot
40-.217x.591 slot
35
1.378 24
1.5
5
.945 .059
.197
27
1.063
7.5
.295
ATA4806 Fastening plate
CAD Data
12
.472
50
M4 1.969
10
.394
10
.394
4
ds_61651_en_aqad: 120713J
AQ-A (AQAD)
CAUTIONS FOR USE
1. Derating design
Derating is essential in any reliable
design and is a significant factor for
product life. Even if the conditions of use
(temperature, current, voltage, etc.) of
the product fall within the absolute
maximum ratings, reliability can be
reduced remarkably when continually
used under high load (high temperature,
high humidity, high current, high voltage,
etc.). Therefore, please derate sufficiently
below the absolute maximum rating and
verify operation of the actual design
before use.
2. Noise and surge protection at the
input side
A high noise surge voltage applied to the
SSR input circuit can cause malfunction
or permanent damage to the device. If
such a high surge is anticipated, use C or
R noise absorber in the input circuit.
R
Input
power
source
3
C
SSR
4
3. If the polarity of the input voltage of
input side is reversed
Reversing the polarity may cause
permanent damage to the device. Take
special care to avoid polarity reversal.
4. In the case of input voltage
containing ripple
If the input voltage contains ripple, the
peak of the ripple should not exceed the
maximum rated control voltage (32V),
and the bottom of the ripple should
exceed the minimum rated control
voltage (4V).
Peak ripple voltage
Valley ripple voltage
0V
5. If the polarity of the load voltage of
output side is reversed
Although the built-in diode for protection
against reverse connection will prevent
damage from occurring if the output
terminals are connected with reverse
polarity, please be aware that the circuit
will short.
6. Spike voltage
If an inductive load generates spike
voltages which exceed the absolute
maximum rating, the spike voltage must
be limited. Typical circuits are shown
below.
2
Add a clamp diode
to the load
SSR
1
Load
2
Add a varistor to
between output
terminals
SSR
1
8. Transportation and storage
1) Extreme vibration during transport will
warp the terminal or damage the relay.
Handle the carton and case with care.
2) Storage under extreme conditions will
cause external appearance defects, and
deterioration of the characteristics. The
following storage conditions are
recommended:
• Temperature: 0 to 45C 32 to 113F
• Humidity: Less than 70% R.H.
• Atmosphere: No harmful gasses such
as sulfurous acid gas, minimal dust.
Load
Even if spike voltages generated at the
load are limited with a clamp diode or
varistor if the circuit wires are long, spike
voltages will occur by inductance. Keep
wires as short as possible to minimize
inductance.
7. Others
1) If an SSR is used in close proximity to
another SSR or heat-generating device,
its ambient temperature may exceed the
allowable level. Carefully plan SSR
layout and ventilation.
2) Terminal connections should be made
by referring to the associated wiring
diagram.
3) When mounting a heat sink, coat it
with a heat conducting compound or
similar in order to improve the heat
dissipation effect.
4) The product is hot during and
immediately after operation. Use caution.
5) When mounting a slim heat sink (AQPHS-SJ20A) on a DIN rail, mount it as per
the instructions in Note of the dimensional drawing. Mounting in the opposite
direction may cause disengagement due
to vibration or impact.
6) For higher reliability, check device
quality under actual operating conditions.
7) As a guide, the tightening torque for
the screw terminals should be approximately 1.0 N·m on the output side and
approximately 0.5 N·m on the input side.
Cautions for Use
ds_61651_en_aqad: 120713J
5