Partly to Be Discontinued:
Agency standard type
Last time buy: September 30, 2016
Subminiature Size
Connector Integrated Type
AV6 (CS)
SWITCHES
FEATURES
• Easy assembling as this switch is connector integrated.
• High contact reliability by simple dust prevension guard
and Au-clad double layer contacts
• Two types of contact form are available, the SPST-NC and
the SPST-NO.
• The lever position can be changed. the standard lever
position and the backward lever position.
• Protection grade: IP40
29.2
10
TYPICAL APPLICATIONS
• Vending machine
• Copying machine
• Printer
• Also for all types of equipment required for maintenance
and inspections.
(Unit: mm)
RoHS compliant
ORDERING INFORMATION
AV 6
Actuators
Operation load
0: Pin plunger
Actuator
2: Hinge lever
4: Simulated roller lever
5: Roller lever
Contact form
2: SPST-NC (Plunger color: Red)
3: SPST-NO (Plunger color: Yellow)
Pin plunger
Hinge lever
Simulated roller lever
Roller lever
Contact material
64: CuNi alloy + Au-clad contact
6th digit of
part number
2
5
0.50N 1.50N
0.20N 0.50N
0.20N 0.50N
0.20N 0.50N
Agency standard
3: UL/C-UL, TÜV
Lever position
Nil: Standard
12: Backward
CONTACT FORM
1) SPST-NC
64
LEVER POSITION
2) SPST-NO
1) Standard
NC
NO
COM
COM
CURRENT CAPACITY (reference)
2) Backward
APPLICABLE CONNECTOR
Easy assembling as this switch is connector integrated.
• Applicable connector: XA connector produced by JST Mfg. Co.,
Ltd.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
100mA
Applicable range
Connector
1mA
0
DC 5V
30V
–1–
AECTB13E 201509-T
Partly to Be Discontinued: Agency standard type
Last time buy: September 30, 2016
AV6 (CS) Subminiature Switches
PRODUCT TYPES
■ Lever position: Standard
Actuator
Partly to Be Discontinued: Agency standard type
Contact form
Operating Force OF, Max.
Pin plunger
Hinge lever
Simulated roller lever
Roller lever
0.50N
1.50N
SPST-NC
AV6202643
AV6205643
SPST-NO
AV6302643
AV6305643
0.20N
0.50N
0.20N
0.50N
0.20N
0.50N
AV6222643
AV6225643
AV6242643
AV6245643
AV6252643
AV6255643
AV6322643
AV6325643
AV6342643
AV6345643
AV6352643
AV6355643
■ Lever position: Backward
Actuator
Partly to Be Discontinued: Agency standard type
Contact form
Operating Force OF, Max.
SPST-NC
AV622212643
AV622512643
AV624212643
AV624512643
AV625212643
AV625512643
0.35N
1.00N
0.35N
1.00N
0.35N
1.00N
Hinge lever
Simulated roller lever
Roller lever
SPST-NO
AV632212643
AV632512643
AV634212643
AV634512643
AV635212643
AV635512643
SPECIFICATIONS
■ Contact rating
Contact
Contact voltage
Resistive load (cos φ ] 1)
Au-clad double layer contact
30V DC
5V DC
0.1A
1mA Low-level circuit rating
■ Characteristics
Expected life
Item
Mechanical (OT max.)
Electrical (Rated load OT max.)
Insulation resistance
Dielectric strength
Between non-continuous terminals
Between each terminal and other
exposed metal parts
Between each terminal and ground
Contact resistance (initial)
Viblation resistance (malfunction vibration resistance)
Specifications
Min. 5 × 105 (at 60 cpm)
Min. 2 × 105 (at 20 cpm)
Min. 100MΩ
1,000 Vrms for 1 min.
1,500 Vrms for 1 min.
1,500 Vrms for 1 min.
100mΩ max. (by voltage drop 0.1A 6 to 8 VDC)
Value includes the resistance between the connector and the lead (#AWG28, length: 50 mm)
10 to 55 Hz at single amplitude of 0.75mm (Contact opening: max. 1msec.)
Connector insertion force
Connector holding force
Connector removal operating times
Allowable operating speed (No load)
Max. operating cycle rate (No load)
Ambient temperature
Unit weight
Contact specifications
Contact material
Applied shock 1.50N type: Min.300m/s2 (Contact opening: Max. 1msec.)
0.50N type: Min.150m/s2 (Contact opening: Max. 1msec.)
Max. 20N (inserted in removal direction)
Min. 20N (extracted by static load, in removal direction)
Max. 5 times (in removal direction)
0.1 to 1,000 mm/s (at pin plunger)
300 cpm
–25 to +85°C (No freezing and condensing)
Approx. 2.5g (pin plunger type)
CuNi alloy + Au-clad
Protection grade
IP40
Shock resistance (malfunction shock resistance)
■ Operating characteristics
1) Lever position: Standard
Actuator
Pin plunger
Hinge lever
Simulated roller lever
Roller lever
Operating Force OF,
Max.
0.50N
1.50N
0.20N
0.50N
0.20N
0.50N
0.20N
0.50N
Release Force RF,
Min.
0.04N
0.25N
0.02N
0.06N
0.02N
0.06N
0.02N
0.06N
Pretravel PT,
Max.
Movement Differential
MD, Max.
Overtravel OT,
Min.
Operating Position
OP
0.6mm
0.1mm
0.4mm
8.4±0.3mm
2.6mm
0.8mm
1.2mm
10.0±0.8mm
2.6mm
0.8mm
1.2mm
12.2±0.8mm
2.6mm
0.8mm
1.2mm
15.7±0.8mm
–2–
AECTB13E 201509-T
Partly to Be Discontinued: Agency standard type
Last time buy: September 30, 2016
AV6 (CS) Subminiature Switches
2) Lever position: Backward
Actuator
Hinge lever
Simulated roller lever
Roller lever
Operating Force OF,
Max.
0.35N
1.00N
0.35N
1.00N
0.35N
1.00N
Release Force RF,
Min.
0.03N
0.10N
0.03N
0.10N
0.03N
0.10N
Pretravel PT,
Max.
Movement Differential
MD, Max.
Overtravel OT,
Min.
Operating Position
OP
1.4mm
0.6mm
0.7mm
9.2±0.6mm
1.4mm
0.6mm
0.7mm
11.3±0.6mm
1.4mm
0.6mm
0.7mm
14.9±0.6mm
DIMENSIONS
The CAD data of the products with a
(Unit: mm) General tolerance: ±0.25
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
■ Pin plunger
External dimensions
CAD Data
Pin plunger
type PT
0.6 max.
3.85
7.6
Pin plunger
+0.05
type OP 10.0 7.7 2.4 −0.1
8.4±0.3
2.5
Base line
2.5
5.7
9.5
−0.1
2.4 +0.05
±0.1
7
±0.08
29.2
Pretravel PT, Max.
Movement Differential MD, Max.
Overtravel OT, Min.
Operating
Distance from
Position OP
mounting hole
0.6mm
0.1mm
0.4mm
8.4±0.3mm
■ Hinge lever
Lever position: Standard
External dimensions
CAD Data
PT
2.6 max.
18.2
12.9
10.0
4.0
OP
10.0±0.08
+0.05
7.7 2.4 −0.1
2.5
−0.1
2.4 +0.05
2.5±0.1
5.7
9.5
7
±0.08
29.2
Pretravel PT, Max.
Movement Differential MD, Max.
Overtravel OT, Min.
Operating
Distance from
Position OP
mounting hole
2.6mm
0.8mm
1.2mm
10.0±0.8mm
Lever position: Backward
External dimensions
CAD Data
18.2
PT
1.4 max.
4.0
2.4
OP
+0.05
9.2±0.6 10.0 7.7 2.4 −0.1
2.5
2.5
5.7
9.5
−0.1
2.4 +0.05
±0.1
±0.08
29.2
–3–
7
Pretravel PT, Max.
Movement Differential MD, Max.
Overtravel OT, Min.
Operating
Distance from
Position OP
mounting hole
1.4mm
0.6mm
0.7mm
9.2±0.6mm
AECTB13E 201509-T
Partly to Be Discontinued: Agency standard type
Last time buy: September 30, 2016
AV6 (CS) Subminiature Switches
■ Simulated roller lever
Lever position: Standard
External dimensions
CAD Data
10.0
4.0
PT
2.6 max.
19.2
12.9
OP
12.2±0.8
+0.05
7.7 2.4 −0.1
2.5
−0.1
2.4 +0.05
2.5±0.1
5.7
7
9.5±0.08
29.2
Pretravel PT, Max.
Movement Differential MD, Max.
Overtravel OT, Min.
Operating
Distance from
Position OP
mounting hole
2.6mm
0.8mm
1.2mm
12.2±0.8mm
Lever position: Backward
External dimensions
CAD Data
PT
1.4 max.
4.0
19.2
2.4
OP
11.3±0.6
10.0
+0.05
7.7 2.4 −0.1
2.5
2.5
5.7
9.5
−0.1
2.4 +0.05
±0.1
7
±0.08
29.2
Pretravel PT, Max.
Movement Differential MD, Max.
1.4mm
0.6mm
Overtravel OT, Min.
Operating
Distance from
Position OP
mounting hole
0.7mm
11.3±0.6mm
Roller lever
Lever position: Standard
External dimensions
CAD Data
PT
2.6 max.
18
12.9
OP
15.7±0.8
10.0
+0.05
7.7 2.4 −0.1
2.5
2.5
5.7
−0.1
2.4 +0.05
±0.1
7
9.5±0.08
29.2
Pretravel PT, Max.
Movement Differential MD, Max.
Overtravel OT, Min.
Operating
Distance from
Position OP
mounting hole
2.6mm
0.8mm
1.2mm
15.7±0.8mm
Lever position: Backward
External dimensions
CAD Data
PT
1.4 max.
18
2.4
OP
14.9±0.6
10.0
+0.05
7.7 2.4 −0.1
2.5
2.5±0.1
5.7
−0.1
2.4 +0.05
9.5±0.08
29.2
–4–
7
Pretravel PT, Max.
Movement Differential MD, Max.
Overtravel OT, Min.
Operating
Distance from
Position OP
mounting hole
1.4mm
0.6mm
0.7mm
14.9±0.6mm
AECTB13E 201509-T
Partly to Be Discontinued: Agency standard type
Last time buy: September 30, 2016
AV6 (CS) Subminiature Switches
CAUTIONS FOR USE
■ Fastening of the switch body
1) To secure the switch, please use an
M2.3 screw on a flat surface and tighten
using a maximum torque of 0.29 N·m. It
is recommended that both flat metal
washer and spring washers be used with
the screws and adhesive be applied to
lock the screws to prevent loosening of
the screws.
2) Be sure to maintain adequate
insulating clearance between each
terminal and ground.
3) When the operation object is in the
free position, force should not be applied
directly to the actuator or pin plunger.
Also force should be applied to the pin
plunger from vertical direction to the
switch.
4) In setting the movement after
operation, the over-travel should be set
more than 70% as a standard.
With the lever type, do not apply
excessive force in the direction opposite
to the movement, or from the horizontal
direction.
■ About the connector
1) The connector on the AV6 (CS) switch
is designed to fit with the XA connector
produced by JST Mfg. Co., Ltd. Do not
use any connector other than the
specified connector, or solder the
terminals directly.
2) Make sure leads are arranged so that
no constant force is applied to them when
the connectors are mated.
3) Keep the connector straight when
inserting it. If it is inserted at an angle, it
may snag near the entrance, or it may be
inserted too forcefully.
4) Problems thought to be caused by the
XA connector, which is specified as
conforming to the AV6 (CS) switch
connector, are not covered by the
warranty. Please contact JST Mfg., Co.,
Ltd. and request cooperation in resolving
the problem.
■ Selection of switch
Please make your selection so that there
will be no problems even if the operating
characteristics vary up to ±20% from the
standard values.
–5–
■ Environment
Avoid using and storing these switches in
a location where they will be exposed to
corrosive gases, silicon, or high dust
levels, all of which can have an adverse
effect on the contacts.
■ Precautions concerning circuits
The AV6 (CS) switch is designed
specifically for low-voltage, low-current
loads. Avoid using it at loads that exceed
the rating load.
■ Quality check under actual loading
conditions
To assure reliability, check the switch
under actual loading conditions. Avoid
any situation that may adversely affect
switching performance.
AECTB13E 201509-T