FEATURES
nting
mou
1. High density mounting is possible.
Even with mounting right next to another
connector, insertion into and removal
from the socket can be done, providing a
saving in the surface mounting space.
Long lever type
Short lever type
2. Lever with original stopper
construction for great strength
The original stopper construction reduces
the possibility of lever damage even
when excess load is applied to the lever
during socket insertion and removal, and
during transportation.
3. Metal pin-less lever construction
Noise prevention is considered in this
construction by not using metal pins,
which, if present, act as noise absorbing
antennas.
4. Incorrect insertion prevention
mechanism.
Because of the box type construction of
the header and the special key that is
used, incorrect insertion can be
prevented.
Also, by means of the special key that is
used, incorrect insertion into an adjacent
connector is prevented.
Compliance with RoHS Directive
ORDERING INFORMATION
1. Socket
AXM
1
1
5
1: MIL connectors (Socket)
10: 10 contacts 14: 14 contacts
34: 34 contacts 40: 40 contacts
16: 16 contacts
50: 50 contacts
20: 20 contacts
60: 60 contacts
26: 26 contacts
64: 64 contacts
30: 30 contacts
0: Without strain relief/10 contacts: with polarity guide
2: Without strain relief/Min. 14 contacts with polarity guide, 10 contacts without polarity guide
4: With strain relief/14 contacts with polarity guide, 10 contacts without polarity guide
9: With strain relief/10 contacts: with polarity guide
Connectors for industrial equipment
1: 1.27 mm
5: Au plating/Au plating
2. Header
AXM
2
1
2: MIL connectors (Header)
10: 10 contacts 14: 14 contacts
34: 34 contacts 40: 40 contacts
16: 16 contacts
50: 50 contacts
20: 20 contacts
60: 60 contacts
26: 26 contacts
64: 64 contacts
30: 30 contacts
0: Long lever
1: Short lever
2: Without lever
0: Straight (Min. 14 contacts with polarity slot, 10 contacts without polarity slot)
1: Angle (Min. 14 contacts with polarity slot, 10 contacts without polarity slot)
8: Straight (10 contacts with polarity slot)
9: Angle (10 contacts with polarity slot)
1: Au plating/Sn plating
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010
AXM
3. Strain relief
AXM
3
3: MIL connectors (Strain relief)
10: 10 contacts 14: 14 contacts
34: 34 contacts 40: 40 contacts
16: 16 contacts
50: 50 contacts
20: 20 contacts
60: 60 contacts
26: 26 contacts
64: 64 contacts
30: 30 contacts
SPECIFICATIONS
1. Characteristics
Item
Rated current
Electrical
characteristics
Breakdown voltage
Insulation resistance
Specifications
Contact resistance
Unit removal force
Composite insertion force
Post holding force
Mechanical
characteristics
Lifetime
characteristics
Min. 0.785N {80gf}/2 contacts
Max. 2.94N {300gf} × no. of contacts
Min. 19.6N {2kgf}
Lever locking strength
Min. 78.5N {8kgf}
Cover strength
Min. 78.5N {8kgf}
By pulling post until coming off
Sockets are pulled to the derection of shaft in the mated
condition
By pulling protector or strain relief to the direction of shaft
500 times
Ambient temperature
–55° to +105°C
Vibration resistance
10 to 55Hz at the double amplitude of 1.52mm
Shock resistance
Detection current: 1 mA
at 500V DC megger
Measured based on the HP4338B measurement method
of JIS C 5402
Measured by steel-pin-gauge with (0.64±0.01)
× (0.64±0.01)mm2 cross section area.
Max. 20mΩ
Insertion and removal life
Environmental
characteristics
Conditions
1A
When the header is connected to our wire-press socket,
the rated current varies depending on the wire used as
shown below.
(AWG#23/#24: 3 A, AWG#26: 2 A, AWG#28: 1 A)
750 V AC for 1 min.
Min. 1000MΩ
490m/s2 {50G}
No opening more than 1µsec. at max. 100mA carrying
current
No opening more than 1µsec. at max. 100mA carrying
current
2. Materials and surface treatment
Part name
Molded portion
Material
Glass reinforced PBT (UL94V-0)
Contact (Socket)
Copper alloy
Post (Header)
Copper alloy
Surface
—
Contact portion: Ni plating on base, Au plating on surface
Pressured portion: Ni plating on base, Au plating on surface
Contact portion: Ni plating on base, Au plating on surface
Terminal portion: Ni plating on base, Sn plating on surface
3. Applicable cable
AWG28 Pitch 1.27mm
PRODUCT TYPES
1. Socket
No. of contacts
10
14
16
20
26
30
34
40
50
60
64
2. Strain relief
No. of
polarity guide
0
1
1
1
1
1
1
1
1
1
1
1
Without strain relief
With strain relief
No. of contacts
Part No.
AXM110215
AXM110015
AXM114215
AXM116215
AXM120215
AXM126215
AXM130215
AXM134215
AXM140215
AXM150215
AXM160215
AXM164215
AXM110415
AXM110915
AXM114415
AXM116415
AXM120415
AXM126415
AXM130415
AXM134415
AXM140415
AXM150415
AXM160415
AXM164415
10
14
16
20
26
30
34
40
50
60
64
AXM310
AXM314
AXM316
AXM320
AXM326
AXM330
AXM334
AXM340
AXM350
AXM360
AXM364
panasonic-electric-works.net/ac
Connectors for industrial equipment
Standard wire
Discontinued as of September 30, 2010
AXM
3. Header
Long lever type
No. of
polarity slot
No. of contacts
0
1
1
1
1
1
1
1
1
1
1
1
10
14
16
20
26
30
34
40
50
60
64
Short lever type
Angle
Straight
Angle
Straight
AXM210011
AXM210091
AXM214011
AXM216011
AXM220011
AXM226011
AXM230011
AXM234011
AXM240011
AXM250011
AXM260011
AXM264011
AXM210001
AXM210081
AXM214001
AXM216001
AXM220001
AXM226001
AXM230001
AXM234001
AXM240001
AXM250001
AXM260001
AXM264001
AXM210111
AXM210191
AXM214111
AXM216111
AXM220111
AXM226111
AXM230111
AXM234111
AXM240111
AXM250111
AXM260111
AXM264111
AXM210101
AXM210181
AXM214101
AXM216101
AXM220101
AXM226101
AXM230101
AXM234101
AXM240101
AXM250101
AXM260101
AXM264101
Notes) 1. A no-lever type is available. This product will be manufactured after receiving your order. Please inquire about delivery.
When ordering change the fourth digit in the part number to “2”.
2. The tray packing quantity for outer carton is 200 pcs.
3. For the available foreign standard products, refer to “STANDARDS CHART” on the end of the catalog.
4. Keys
Product name
Polarity key
Incorrect insertion
prevention key
Part No.
AXM8001
AXM8002
DIMENSIONS (Unit: mm)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://panasonic-electric-works.net/ac
• Socket
With strain relief
Strain relief
A
Without strain relief
6.0
15.9
14.3
14.0
10.5
A
6.0
Housing
Polarity guide
Connectors for industrial equipment
B
3.7
Protector
10.5
7.0
C
B
3.7
2.54±0.15
C
2.54±0.15
2.54±0.15
Dimension table (mm)
No. of
contacts
10
14
16
20
26
30
34
40
50
60
64
No. of
Polarity slot
0
1
1
1
1
1
1
1
1
1
1
1
A
B
C
17.3
10.16
—
17.3
22.4
24.9
30.0
37.6
42.7
47.8
55.4
68.1
80.8
85.9
10.16
15.24
17.78
22.86
30.48
35.56
40.64
48.26
60.96
73.66
78.74
2.54±0.15
General tolerance: ±0.3
Cross section view
With strain relief
Without strain relief
0.8
1.0
4.35
1.4
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010
AXM
• Header (Long lever type)
Terminal dimensions
Angle terminal
CAD Data
Straight terminal
F
C
2.54±0.15
26.4
6.5
17.3
13.9
3.0
3.59
0.5±0.05
2.85
3.0
0.5±0.05
2.54±0.15
2-2.6 dia.
Recommended PC board pattern
(BOTTOM VIEW)
2.54±0.15
E
B
A
3.95
Angle terminal
8.4
8.7
2-2.6 dia.
D
10
14
16
20
26
30
34
40
50
60
64
(17.3)
(13.9)
0.74
General tolerance: ±0.3
Dimension table (mm)
No. of contacts
0.80+0.1
0 dia.
No. of Polarity slot
0
1
1
1
1
1
1
1
1
1
1
1
A
32.0
32.0
37.1
39.6
44.7
52.3
57.4
62.5
70.1
82.8
95.5
100.6
B
21.84
21.84
26.92
29.46
34.54
42.16
47.24
52.32
59.94
72.64
85.34
90.42
C
17.53
17.53
22.61
25.15
30.23
37.85
42.93
48.01
55.63
68.33
81.03
86.11
D
27.9
27.9
33.0
35.6
40.6
48.3
53.34
58.4
66.0
78.7
91.4
96.5
E
10.16
10.16
15.24
17.78
22.86
30.48
35.56
40.64
48.26
60.96
73.66
78.74
2.54±0.05
F
38.6
38.6
43.7
46.2
51.3
58.9
64.0
69.1
76.7
89.4
102.1
107.2
2.85
2-3.2 dia.
(M3 screws)
2.54±0.05
E±0.1
B±0.1
(A)
Straight terminal
0.80+0.1
0 dia.
1.52
2-3.2 dia.
(M3 screws)
(8.7)
(8.4)
3.95
2.54±0.05
2.54±0.05
E±0.1
D±0.1
(A)
Note) Dimensions of A, B, D and E are the same as the
header dimensions.
• Header [Short lever]
Terminal dimensions
Angle terminal
CAD Data
Straight terminal
F
C
2.54±0.15
6.5
17.3
13.9
2.85
3.0
3.59
0.5±0.05
3.0
0.5±0.05
2.54±0.15
2-2.6 dia.
2.54±0.15
E
B
A
Recommended PC board pattern
(BOTTOM VIEW)
3.95
Angle terminal
8.4
8.7
2-2.6 dia.
D
14
No. of Polarity slot
0
1
1
A
32.0
32.0
37.1
B
21.84
21.84
26.92
C
17.53
17.53
22.61
D
27.9
27.9
33.0
E
10.16
10.16
15.24
F
35.0
35.0
40.1
16
20
26
30
34
40
50
60
64
1
1
1
1
1
1
1
1
1
39.6
44.7
52.3
57.4
62.5
70.1
82.8
95.5
100.6
29.46
34.54
42.16
47.24
52.32
59.94
72.64
85.34
90.42
25.15
30.23
37.85
42.93
48.01
55.63
68.33
81.03
86.11
35.6
40.6
48.3
53.34
58.4
66.0
78.7
91.4
96.5
17.78
22.86
30.48
35.56
40.64
48.26
60.96
73.66
78.74
42.7
47.7
55.4
60.4
65.5
73.1
85.8
98.5
103.6
10
(17.3)
(13.9)
0.74
General tolerance: ±0.3
Dimension table (mm)
No. of contacts
0.80+0.1
0 dia.
2.54±0.05
2.54±0.05
E±0.1
B±0.1
(A)
2.85
2-3.2 dia.
(M3 screws)
Straight terminal
1.52
0.80+0.1
0 dia.
2-3.2 dia.
(M3 screws)
(8.7)
(8.4)
3.95
2.54±0.05
2.54±0.05
E±0.1
D±0.1
(A)
Note) Dimensions of A, B, D and E are the same as the
header dimensions.
panasonic-electric-works.net/ac
Connectors for industrial equipment
22.6
Discontinued as of September 30, 2010
AXM
CABLE NO. AND TERMINAL POSITION CORRELATION DRAWING
Socket
Header (Angle terminal)
Terminal numbers are not indicated on
the connector. Using the triangle mark as
reference, the connection operations and
printed circuit board design should be
carried out.
When the cable numbers are temporarily
assigned from the end as 1, 2, 3, 4 ... n,
the corresponding terminal number
positions for the socket are as shown in
the drawing on the left. The header
terminal positions and corresponding
positions are shown in the drawing on the
left.
Triangle mark
Triangle mark
Triangle mark
n
n-1
1 3
n-1
2
3 1
Header (Straight terminal)
n
2
4
4 2
n
1 23 4
Cable
n
Cable No.
n-1
3 1 Triangle mark
COMBINATION OF HEADER AND SOCKET
With strain relief
Without strain relief
Header
Socket
Strain relief
Without strain
relief
Long lever type
Long lever
type
Good
Short lever
type
Not good
Not good
Good
Short lever type
REGARDING REVERSE AND INCORRECT INSERTION PREVENTION
Connectors for industrial equipment
1. Reverse insertion prevention
mechanism
The header polarity slot and socket
polarity guide of these MIL connectors
make for a construction which prevents
reverse insertion. (However, the 10contact type does not feature this
construction.)
2. Polarity key (AXM8001) for double
prevention of reverse insertion
Reverse insertion is doubly prevented by
inserting the polarity key (AXM8001) into
the header to create a projection and by
aligning this projection with the cutout in
the socket.
Socket
Incorrect insertion
prevention key
Cutout
Projection
Polarity guide
Polarity key
now in place
Polarity slot
Header
3. Incorrect insertion prevention key
(AXM8002) ideal for preventing
incorrect insertion into adjacent
connectors when a miltiple number of
MIL connectors with the same number
of contacts are used
Incorrect insertion is prevented by
plugging the hole in the socket with the
incorrect insertion prevention key
(AXM8002) and then by removing or
cutting off the pin of the corresponding
header.
Plarity key
Hand-held part
(break off after insertion)
Hand-held part
(break off
after insertion)
Remove corresponding pin
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010
AXM
NOTES
4. Regarding soldering of the header
Soldering should be carried out under the
conditions given below.
260°C: Within 10 seconds
300°C: Within 5 seconds
350°C: Within 3 seconds
5. Regarding the handling of header
terminals
Care should be taken with the header
terminals because repeated bending of
the terminals can lead to damage.
6. Regarding the cable pressure
connection tool
The special tool provided by our
company for cutting the cable and
making the pressure connections should
be used.
7. Regarding the selection of header
type
When making the selection of the header,
the following factors should be used for
the selection.
Condition
Header
Long lever
type
Short lever
type
Repeated
vibration
and shock
Occasional
Force used
vibration
on cable
and shock
Very good
Very good
Very good
Good
Good
Not good
Note) Vibration: 9.8 m/s {1G}/10 to 150 Hz
Shock: 49 m/s2 {5G}
The above should be considered as criteria.
2
For other details, please verify with the
product specification sheets.
Connectors for industrial equipment
1. Regarding design of printed circuit
board
The connector terminal numbers are not
indicated. Using the triangle mark as
reference, the printed circuit board
design and the cable connection
operations can be carried out.
2. Regarding insertion into and
removal from the socket
When inserting or removing the
connector, be careful not to pull the
cable. Hold the socket by hand to remove
the connector when the no-lever type is
used. With the lever type header, removal
is easy.
When the socket is unconnected, be
careful not to apply excessive force to the
levers.
3. Regarding external force applied to
the cable
When there is the possibility that external
force may be applied to the cable, or in
the case of vibration being applied to the
connector cable, a strain relief socket
should be used.
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010
AXY
TOOLS FOR
FLAT CABLE CONNECTOR
CABLE CUTTER
FLAT CABLE CONNECTOR
TOOLS (AXY)
FEATURES
NOTES
1. Flat cable (from 10 to 64 contacts) can
be cut.
2. Accurate cutting only by setting cable
to the guide.
3. Cutting knife can be fixed by clamper
from the side and exchanged easily.
4. Safety cover for cutting knife is
equipment.
5. The replacement blade of a
commercially available box cutter can be
used as the cable cutter blade.
1. Setting of flat cable
First, set the guide plate at the correct
width. Then fix the cable and cut it.
2. Exchange of cutting knife
Push to attach the knife to the stopper pin
of cutter holder and then set it.
3. Safety cover
Cutting work should be done with safety
cover set. Please do not put your hand
inside of safety cover set.
4. Do not remodel this product or use
it for other purposes.
(mm)
PRODUCT TYPES
Product name
Cable cutter
Compliance with RoHS Directive
Part No.
AXY80000
Pressing plate
Guid plates
Center locator
Handle
Attachment
AXY10000
Compliance with RoHS Directive
1. Operation without worry of
connecters becoming damaged
When pressure welding, the connector
will not break even if pressed too hard
because the guide plate acts as a
stopper.
2. Easy operation
Designed with the operator in mind,
pressure welding is sure and easy with
minimal force needed when operating the
lever. It is also well suited to repetitive
operation.
3. Using the same unit, all types of
connectors can be pressure welded
by simply replacing center locator and
guide plate.
4. Pressure welding of 10 to 64 strand
cable is easily accomplished by
changing the position of the guide
plate.
5. Positioning of the connector and
cable is easily accomplished with the
guide plate.
6. After pressure welding a flat cable,
the connector can be easily removed
by pressing the handle to pop it out.
7. Even if the connector type changes,
the cover is always face down and
pressure welding is always possible.
Cables will never be displaced during
pressure welding.
PRODUCT TYPES
Products name
Pressure welding unit
Attachment
Center locator
Accessories
Guide plate
Spacer
Part No.
AXY10000
AXY20101
AXY20201
AXY20202
AXY20203
AXY20205
Remarks
MIL and PCB types, Cable pitch 1.27mm
MIL type
PCB Mini-dip type
PCB IC type, Terminal row pitch 7.62mm
PCB IC type, Terminal row pitch 15.24mm
AXY20301
AXY20302
AXY20303
AXY20305
AXY20401
AXY20404
AXY20405
AXY20406
MIL type
PCB Mini-dip type
PCB IC type, Terminal row pitch 7.62mm
PCB IC type, Terminal row pitch 15.24mm
Mini-dip type, Terminal row pitch 2.54mm, 30 to 64 contacts
IC type, Terminal row pitch 15.24mm, 24 to 40 contacts
Mini-dip type, Terminal row pitch 2.54mm, 10 to 26 contacts
IC type, Terminal row pitch 7.62mm, 14 to 20 contacts
Note) The pressure welding unit is not include the accessories.
panasonic-electric-works.net/ac
Connectors for industrial equipment
PRESSURE WELDING UNIT
FEATURES
Discontinued as of September 30, 2010
AXY
COMBINATION OF ACCESSORIES
Applicable socket
MIL type
No. of contacts
Every type
10 to 26
30 to 64
14 to 20
24 to 40
PCB (Mini-dip type)
PCB (IC type)
Attachment
Center locator
AXY20201
Guide plate
AXY20301
AXY20202
AXY20302
AXY20203
AXY20205
AXY20303
AXY20305
AXY20101
Spacer
—
AXY20405
AXY20401
AXY20406
AXY20404
SAFETY NOTES
1. Do not do the following dangerous
actions when using the pressure
welder.
• Insert hand or fingers beneath the
pressure plate when operating the lever.
• Allow your fingers to get close to
moving parts when operating the lever.
• Let go of the lever when in progress
after pressure welding a connector.
(Be sure to keep your hand on the lever
all the way to the end.
Otherwise the lever might snap back
with considerable force.)
2. Secure the pressure welder to the
work bench to prevent it from falling
over. Also, do not apply excessive
force to the lever when pressure
welding (such as by applying the full
weight of your body).
PRESSING PLATE OF PRESSURE WELDING UNIT
1. The pressing plate consists of the
pressing plate main unit and MIL/PCB
type connector plate.
2. Proceed with the pressure connection
of MIL type connectors (AXM1 series)
and PCB type connectors (AXP series)
with the MIL/PCB connector plate
attached to the pressing plate main unit.
Use the hexagonal head bolt to mount
and remove the MIL/PCB type connector
plate.
When pressure-welding MIL/PCB type connectors
Pressing plate main unit
Hexagonal head bolt
Resin panel
MIL/PCB type connector plate
Connectors for industrial equipment
DIMENSIONS (Unit: mm)
• Pressure welding unit
130
Handle
400
Pressing plate
Location for attachment
310
150
• Accessories
18
130
Spacer
130
Attachment
Center locator
Guide plate
Spacer
Center locator
Guide plate
Handle
Attachment
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010
AXY
NOTES
1. Sockets setting
After covers are temporary fixed with
housing (or base), sockets are set at the
gutter of center locator. (See Fig. 1)
2. Method of inserting flat cable
The guide plate is set at the correct figure
of scale, corresponding to the number of
contacts (cable width). Then cable is
inserted along with the guide until it
reaches at the stopper. (See Fig. 2)
3. Pressure connection
After adjusting the lower limit of the
pressing plate, the connectors should be
pressed. Since the guide plate is the
stopper, the connectors should be
pressed until contacting the pressing
plate to the guide plate.
In case of PCB types, however, spacers
should be placed over the base.
(See Fig. 2)
4. Strain relief
Regarding MIL type, strain relief should
be fixed manually after pressure
connection of cables. (See Fig. 3)
5. Be sure to use our pressure welding
unit and its accessories when
conducting pressure welding.
CABLE PRESSURE WELDING
MIL type
Housing (or base)
Guide plate
Pressing plate
Pressing plate
Protector (or cover)
Center locator
MIL type
PCB type
Flat cable
Center locator
PCB type
Pressing
plate
Protector
Center locator
Fig. 3 Set condition of strain relief
Pressing plate
Cover
Fig. 1 Socket set condition
Spacer
Fig. 2 Pressure welding condition
1. Cable Cutter
1) Never remove the safety cover
2) Never insert your finger inside the
safety cover
3) Use on a stable surface
4) Do not alter this product, or use it for
other purposes
2. Pressure Welding Unit
1) Do not place fingers beneath the
pressurized plate or in or near moving
parts, while the lever is being operated.
2) Lock the unit in place on a
workbench or the like.
3) Do not alter this product, or use it for
other purposes
panasonic-electric-works.net/ac
Connectors for industrial equipment
SAFETY NOTES FOR SPECIALIZED TOOLS
Discontinued as of September 30, 2010
AXH
HARNESS FABRICATION FOR FLAT CABLE CONNECTOR
NOTES WHEN FABRICATING HARNESSES
1. Common items
1) Select the appropriate connector and
cable according to the conditions of use.
2) It is recommended that our cable
cutter and pressure welding unit be used.
3) After making the pressure welding, the
condition of the connection should be
confirmed.
4) Because there are standard terminal
layout and reverse terminal layout for
PCB type connectors, the connector
suitable for the use should be selected.
2. Cable cutter
1) The cable should be cut at right angles
to the corresponding length.
2) Use a sharp cutter for making the cut.
3) When setting the cable length, the
pressure welding portion and strain relief
coil should be considered and set
accordingly.
For our product, the following cable length is necessary. (For each side)
MIL type socket
PCB type connector
Without strain relief
With strain relief
Mini-dip type
IC type 14 to 20 contacts
IC type 24 and 40 contacts
6mm
15mm
7mm
10mm
20mm
3. Cable pressure welding
1) Bring the cable end surface in line with
the connector end surface, and set in the
groove of the cable guide of the protector.
2) When making a cable pressure
welding for a PCB type connector, it is
recommended that a spacer be used.
This can prevent breakage of the
terminals.
Example 1: MIL type and MIL type
Cable mark
Cable mark
Example 2: PCB type and PCB type
Connectors for industrial equipment
Standard terminal layout
Reverse terminal layout
Cable mark
Cable mark
Cable mark
Cable mark
Example 3: PCB type and MIL type
Standard terminal layout
Reverse terminal layout
Cable mark
Cable mark
Cable mark
Cable mark
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010
AXH
HARNESS ASSEMBLY ORDERING INFORMATION
Number of
contacts for
connector
cable
Left connector type
Cable type and length
Right connector type
AXH
AXH connector harness designation
Number of contacts for connector or cable
Left connector type (see Note 1)
Connection of connector and cable (see Note 2)
Cable types
Standard type: Stranded AWG 28: 1
Fluted type:
Stranded AWG 28: 2
Cable mark
Front:
1
Rear:
2
Not specified: 3
Cable length (3 digits)
Example: 020 for 20 cm (Only 5 cm and longer available.)
Right connector type (see Note 1)
Connection of connector and cable (see Note 2)
Note 1) Connector type
MIL type connector
PCB type connector
Mini-dip type
IC type
Type
Without strain relief
With strain relief
Srandard terminal layout
Reverse terminal layout
Reverse terminal layout
Order No.
M12
M14
P42
P46
P56
Note 2) Connection of connector and cable
Order No.
1
2
3
4
5
6
7
8
Left connector
Right connector
Cable mounting
Strain relief
Upper side
Lower side
Without strain relief
Upper side
Lower side
With strain relief
We slso accept orders for harnessed products. Call for more information.
panasonic-electric-works.net/ac
Connectors for industrial equipment
Connector