0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AXM130415

AXM130415

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    MIL30PINSCONN

  • 数据手册
  • 价格&库存
AXM130415 数据手册
Discontinued as of September 30, 2010 AXM MIL CONNECTORS (AXM) FOR PC BOARD TO FLAT CABLE ity Dens FEATURES nting mou 1. High density mounting is possible. Even with mounting right next to another connector, insertion into and removal from the socket can be done, providing a saving in the surface mounting space. Long lever type Short lever type 2. Lever with original stopper construction for great strength The original stopper construction reduces the possibility of lever damage even when excess load is applied to the lever during socket insertion and removal, and during transportation. 3. Metal pin-less lever construction Noise prevention is considered in this construction by not using metal pins, which, if present, act as noise absorbing antennas. 4. Incorrect insertion prevention mechanism. Because of the box type construction of the header and the special key that is used, incorrect insertion can be prevented. Also, by means of the special key that is used, incorrect insertion into an adjacent connector is prevented. Compliance with RoHS Directive ORDERING INFORMATION 1. Socket AXM 1 1 5 1: MIL connectors (Socket) 10: 10 contacts 14: 14 contacts 34: 34 contacts 40: 40 contacts 16: 16 contacts 50: 50 contacts 20: 20 contacts 60: 60 contacts 26: 26 contacts 64: 64 contacts 30: 30 contacts 0: Without strain relief/10 contacts: with polarity guide 2: Without strain relief/Min. 14 contacts with polarity guide, 10 contacts without polarity guide 4: With strain relief/14 contacts with polarity guide, 10 contacts without polarity guide 9: With strain relief/10 contacts: with polarity guide Connectors for industrial equipment 1: 1.27 mm 5: Au plating/Au plating 2. Header AXM 2 1 2: MIL connectors (Header) 10: 10 contacts 14: 14 contacts 34: 34 contacts 40: 40 contacts 16: 16 contacts 50: 50 contacts 20: 20 contacts 60: 60 contacts 26: 26 contacts 64: 64 contacts 30: 30 contacts 0: Long lever 1: Short lever 2: Without lever 0: Straight (Min. 14 contacts with polarity slot, 10 contacts without polarity slot) 1: Angle (Min. 14 contacts with polarity slot, 10 contacts without polarity slot) 8: Straight (10 contacts with polarity slot) 9: Angle (10 contacts with polarity slot) 1: Au plating/Sn plating panasonic-electric-works.net/ac Discontinued as of September 30, 2010 AXM 3. Strain relief AXM 3 3: MIL connectors (Strain relief) 10: 10 contacts 14: 14 contacts 34: 34 contacts 40: 40 contacts 16: 16 contacts 50: 50 contacts 20: 20 contacts 60: 60 contacts 26: 26 contacts 64: 64 contacts 30: 30 contacts SPECIFICATIONS 1. Characteristics Item Rated current Electrical characteristics Breakdown voltage Insulation resistance Specifications Contact resistance Unit removal force Composite insertion force Post holding force Mechanical characteristics Lifetime characteristics Min. 0.785N {80gf}/2 contacts Max. 2.94N {300gf} × no. of contacts Min. 19.6N {2kgf} Lever locking strength Min. 78.5N {8kgf} Cover strength Min. 78.5N {8kgf} By pulling post until coming off Sockets are pulled to the derection of shaft in the mated condition By pulling protector or strain relief to the direction of shaft 500 times Ambient temperature –55° to +105°C Vibration resistance 10 to 55Hz at the double amplitude of 1.52mm Shock resistance Detection current: 1 mA at 500V DC megger Measured based on the HP4338B measurement method of JIS C 5402 Measured by steel-pin-gauge with (0.64±0.01) × (0.64±0.01)mm2 cross section area. Max. 20mΩ Insertion and removal life Environmental characteristics Conditions 1A When the header is connected to our wire-press socket, the rated current varies depending on the wire used as shown below. (AWG#23/#24: 3 A, AWG#26: 2 A, AWG#28: 1 A) 750 V AC for 1 min. Min. 1000MΩ 490m/s2 {50G} No opening more than 1µsec. at max. 100mA carrying current No opening more than 1µsec. at max. 100mA carrying current 2. Materials and surface treatment Part name Molded portion Material Glass reinforced PBT (UL94V-0) Contact (Socket) Copper alloy Post (Header) Copper alloy Surface — Contact portion: Ni plating on base, Au plating on surface Pressured portion: Ni plating on base, Au plating on surface Contact portion: Ni plating on base, Au plating on surface Terminal portion: Ni plating on base, Sn plating on surface 3. Applicable cable AWG28 Pitch 1.27mm PRODUCT TYPES 1. Socket No. of contacts 10 14 16 20 26 30 34 40 50 60 64 2. Strain relief No. of polarity guide 0 1 1 1 1 1 1 1 1 1 1 1 Without strain relief With strain relief No. of contacts Part No. AXM110215 AXM110015 AXM114215 AXM116215 AXM120215 AXM126215 AXM130215 AXM134215 AXM140215 AXM150215 AXM160215 AXM164215 AXM110415 AXM110915 AXM114415 AXM116415 AXM120415 AXM126415 AXM130415 AXM134415 AXM140415 AXM150415 AXM160415 AXM164415 10 14 16 20 26 30 34 40 50 60 64 AXM310 AXM314 AXM316 AXM320 AXM326 AXM330 AXM334 AXM340 AXM350 AXM360 AXM364 panasonic-electric-works.net/ac Connectors for industrial equipment Standard wire Discontinued as of September 30, 2010 AXM 3. Header Long lever type No. of polarity slot No. of contacts 0 1 1 1 1 1 1 1 1 1 1 1 10 14 16 20 26 30 34 40 50 60 64 Short lever type Angle Straight Angle Straight AXM210011 AXM210091 AXM214011 AXM216011 AXM220011 AXM226011 AXM230011 AXM234011 AXM240011 AXM250011 AXM260011 AXM264011 AXM210001 AXM210081 AXM214001 AXM216001 AXM220001 AXM226001 AXM230001 AXM234001 AXM240001 AXM250001 AXM260001 AXM264001 AXM210111 AXM210191 AXM214111 AXM216111 AXM220111 AXM226111 AXM230111 AXM234111 AXM240111 AXM250111 AXM260111 AXM264111 AXM210101 AXM210181 AXM214101 AXM216101 AXM220101 AXM226101 AXM230101 AXM234101 AXM240101 AXM250101 AXM260101 AXM264101 Notes) 1. A no-lever type is available. This product will be manufactured after receiving your order. Please inquire about delivery. When ordering change the fourth digit in the part number to “2”. 2. The tray packing quantity for outer carton is 200 pcs. 3. For the available foreign standard products, refer to “STANDARDS CHART” on the end of the catalog. 4. Keys Product name Polarity key Incorrect insertion prevention key Part No. AXM8001 AXM8002 DIMENSIONS (Unit: mm) The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac • Socket With strain relief Strain relief A Without strain relief 6.0 15.9 14.3 14.0 10.5 A 6.0 Housing Polarity guide Connectors for industrial equipment B 3.7 Protector 10.5 7.0 C B 3.7 2.54±0.15 C 2.54±0.15 2.54±0.15 Dimension table (mm) No. of contacts 10 14 16 20 26 30 34 40 50 60 64 No. of Polarity slot 0 1 1 1 1 1 1 1 1 1 1 1 A B C 17.3 10.16 — 17.3 22.4 24.9 30.0 37.6 42.7 47.8 55.4 68.1 80.8 85.9 10.16 15.24 17.78 22.86 30.48 35.56 40.64 48.26 60.96 73.66 78.74 2.54±0.15 General tolerance: ±0.3 Cross section view With strain relief Without strain relief 0.8 1.0 4.35 1.4 panasonic-electric-works.net/ac Discontinued as of September 30, 2010 AXM • Header (Long lever type) Terminal dimensions Angle terminal CAD Data Straight terminal F C 2.54±0.15 26.4 6.5 17.3 13.9 3.0 3.59 0.5±0.05 2.85 3.0 0.5±0.05 2.54±0.15 2-2.6 dia. Recommended PC board pattern (BOTTOM VIEW) 2.54±0.15 E B A 3.95 Angle terminal 8.4 8.7 2-2.6 dia. D 10 14 16 20 26 30 34 40 50 60 64 (17.3) (13.9) 0.74 General tolerance: ±0.3 Dimension table (mm) No. of contacts 0.80+0.1 0 dia. No. of Polarity slot 0 1 1 1 1 1 1 1 1 1 1 1 A 32.0 32.0 37.1 39.6 44.7 52.3 57.4 62.5 70.1 82.8 95.5 100.6 B 21.84 21.84 26.92 29.46 34.54 42.16 47.24 52.32 59.94 72.64 85.34 90.42 C 17.53 17.53 22.61 25.15 30.23 37.85 42.93 48.01 55.63 68.33 81.03 86.11 D 27.9 27.9 33.0 35.6 40.6 48.3 53.34 58.4 66.0 78.7 91.4 96.5 E 10.16 10.16 15.24 17.78 22.86 30.48 35.56 40.64 48.26 60.96 73.66 78.74 2.54±0.05 F 38.6 38.6 43.7 46.2 51.3 58.9 64.0 69.1 76.7 89.4 102.1 107.2 2.85 2-3.2 dia. (M3 screws) 2.54±0.05 E±0.1 B±0.1 (A) Straight terminal 0.80+0.1 0 dia. 1.52 2-3.2 dia. (M3 screws) (8.7) (8.4) 3.95 2.54±0.05 2.54±0.05 E±0.1 D±0.1 (A) Note) Dimensions of A, B, D and E are the same as the header dimensions. • Header [Short lever] Terminal dimensions Angle terminal CAD Data Straight terminal F C 2.54±0.15 6.5 17.3 13.9 2.85 3.0 3.59 0.5±0.05 3.0 0.5±0.05 2.54±0.15 2-2.6 dia. 2.54±0.15 E B A Recommended PC board pattern (BOTTOM VIEW) 3.95 Angle terminal 8.4 8.7 2-2.6 dia. D 14 No. of Polarity slot 0 1 1 A 32.0 32.0 37.1 B 21.84 21.84 26.92 C 17.53 17.53 22.61 D 27.9 27.9 33.0 E 10.16 10.16 15.24 F 35.0 35.0 40.1 16 20 26 30 34 40 50 60 64 1 1 1 1 1 1 1 1 1 39.6 44.7 52.3 57.4 62.5 70.1 82.8 95.5 100.6 29.46 34.54 42.16 47.24 52.32 59.94 72.64 85.34 90.42 25.15 30.23 37.85 42.93 48.01 55.63 68.33 81.03 86.11 35.6 40.6 48.3 53.34 58.4 66.0 78.7 91.4 96.5 17.78 22.86 30.48 35.56 40.64 48.26 60.96 73.66 78.74 42.7 47.7 55.4 60.4 65.5 73.1 85.8 98.5 103.6 10 (17.3) (13.9) 0.74 General tolerance: ±0.3 Dimension table (mm) No. of contacts 0.80+0.1 0 dia. 2.54±0.05 2.54±0.05 E±0.1 B±0.1 (A) 2.85 2-3.2 dia. (M3 screws) Straight terminal 1.52 0.80+0.1 0 dia. 2-3.2 dia. (M3 screws) (8.7) (8.4) 3.95 2.54±0.05 2.54±0.05 E±0.1 D±0.1 (A) Note) Dimensions of A, B, D and E are the same as the header dimensions. panasonic-electric-works.net/ac Connectors for industrial equipment 22.6 Discontinued as of September 30, 2010 AXM CABLE NO. AND TERMINAL POSITION CORRELATION DRAWING Socket Header (Angle terminal) Terminal numbers are not indicated on the connector. Using the triangle mark as reference, the connection operations and printed circuit board design should be carried out. When the cable numbers are temporarily assigned from the end as 1, 2, 3, 4 ... n, the corresponding terminal number positions for the socket are as shown in the drawing on the left. The header terminal positions and corresponding positions are shown in the drawing on the left. Triangle mark Triangle mark Triangle mark n n-1 1 3 n-1 2 3 1 Header (Straight terminal) n 2 4 4 2 n 1 23 4 Cable n Cable No. n-1 3 1 Triangle mark COMBINATION OF HEADER AND SOCKET With strain relief Without strain relief Header Socket Strain relief Without strain relief Long lever type Long lever type Good Short lever type Not good Not good Good Short lever type REGARDING REVERSE AND INCORRECT INSERTION PREVENTION Connectors for industrial equipment 1. Reverse insertion prevention mechanism The header polarity slot and socket polarity guide of these MIL connectors make for a construction which prevents reverse insertion. (However, the 10contact type does not feature this construction.) 2. Polarity key (AXM8001) for double prevention of reverse insertion Reverse insertion is doubly prevented by inserting the polarity key (AXM8001) into the header to create a projection and by aligning this projection with the cutout in the socket. Socket Incorrect insertion prevention key Cutout Projection Polarity guide Polarity key now in place Polarity slot Header 3. Incorrect insertion prevention key (AXM8002) ideal for preventing incorrect insertion into adjacent connectors when a miltiple number of MIL connectors with the same number of contacts are used Incorrect insertion is prevented by plugging the hole in the socket with the incorrect insertion prevention key (AXM8002) and then by removing or cutting off the pin of the corresponding header. Plarity key Hand-held part (break off after insertion) Hand-held part (break off after insertion) Remove corresponding pin panasonic-electric-works.net/ac Discontinued as of September 30, 2010 AXM NOTES 4. Regarding soldering of the header Soldering should be carried out under the conditions given below. 260°C: Within 10 seconds 300°C: Within 5 seconds 350°C: Within 3 seconds 5. Regarding the handling of header terminals Care should be taken with the header terminals because repeated bending of the terminals can lead to damage. 6. Regarding the cable pressure connection tool The special tool provided by our company for cutting the cable and making the pressure connections should be used. 7. Regarding the selection of header type When making the selection of the header, the following factors should be used for the selection. Condition Header Long lever type Short lever type Repeated vibration and shock Occasional Force used vibration on cable and shock Very good Very good Very good Good Good Not good Note) Vibration: 9.8 m/s {1G}/10 to 150 Hz Shock: 49 m/s2 {5G} The above should be considered as criteria. 2 For other details, please verify with the product specification sheets. Connectors for industrial equipment 1. Regarding design of printed circuit board The connector terminal numbers are not indicated. Using the triangle mark as reference, the printed circuit board design and the cable connection operations can be carried out. 2. Regarding insertion into and removal from the socket When inserting or removing the connector, be careful not to pull the cable. Hold the socket by hand to remove the connector when the no-lever type is used. With the lever type header, removal is easy. When the socket is unconnected, be careful not to apply excessive force to the levers. 3. Regarding external force applied to the cable When there is the possibility that external force may be applied to the cable, or in the case of vibration being applied to the connector cable, a strain relief socket should be used. panasonic-electric-works.net/ac Discontinued as of September 30, 2010 AXY TOOLS FOR FLAT CABLE CONNECTOR CABLE CUTTER FLAT CABLE CONNECTOR TOOLS (AXY) FEATURES NOTES 1. Flat cable (from 10 to 64 contacts) can be cut. 2. Accurate cutting only by setting cable to the guide. 3. Cutting knife can be fixed by clamper from the side and exchanged easily. 4. Safety cover for cutting knife is equipment. 5. The replacement blade of a commercially available box cutter can be used as the cable cutter blade. 1. Setting of flat cable First, set the guide plate at the correct width. Then fix the cable and cut it. 2. Exchange of cutting knife Push to attach the knife to the stopper pin of cutter holder and then set it. 3. Safety cover Cutting work should be done with safety cover set. Please do not put your hand inside of safety cover set. 4. Do not remodel this product or use it for other purposes. (mm) PRODUCT TYPES Product name Cable cutter Compliance with RoHS Directive Part No. AXY80000 Pressing plate Guid plates Center locator Handle Attachment AXY10000 Compliance with RoHS Directive 1. Operation without worry of connecters becoming damaged When pressure welding, the connector will not break even if pressed too hard because the guide plate acts as a stopper. 2. Easy operation Designed with the operator in mind, pressure welding is sure and easy with minimal force needed when operating the lever. It is also well suited to repetitive operation. 3. Using the same unit, all types of connectors can be pressure welded by simply replacing center locator and guide plate. 4. Pressure welding of 10 to 64 strand cable is easily accomplished by changing the position of the guide plate. 5. Positioning of the connector and cable is easily accomplished with the guide plate. 6. After pressure welding a flat cable, the connector can be easily removed by pressing the handle to pop it out. 7. Even if the connector type changes, the cover is always face down and pressure welding is always possible. Cables will never be displaced during pressure welding. PRODUCT TYPES Products name Pressure welding unit Attachment Center locator Accessories Guide plate Spacer Part No. AXY10000 AXY20101 AXY20201 AXY20202 AXY20203 AXY20205 Remarks MIL and PCB types, Cable pitch 1.27mm MIL type PCB Mini-dip type PCB IC type, Terminal row pitch 7.62mm PCB IC type, Terminal row pitch 15.24mm AXY20301 AXY20302 AXY20303 AXY20305 AXY20401 AXY20404 AXY20405 AXY20406 MIL type PCB Mini-dip type PCB IC type, Terminal row pitch 7.62mm PCB IC type, Terminal row pitch 15.24mm Mini-dip type, Terminal row pitch 2.54mm, 30 to 64 contacts IC type, Terminal row pitch 15.24mm, 24 to 40 contacts Mini-dip type, Terminal row pitch 2.54mm, 10 to 26 contacts IC type, Terminal row pitch 7.62mm, 14 to 20 contacts Note) The pressure welding unit is not include the accessories. panasonic-electric-works.net/ac Connectors for industrial equipment PRESSURE WELDING UNIT FEATURES Discontinued as of September 30, 2010 AXY COMBINATION OF ACCESSORIES Applicable socket MIL type No. of contacts Every type 10 to 26 30 to 64 14 to 20 24 to 40 PCB (Mini-dip type) PCB (IC type) Attachment Center locator AXY20201 Guide plate AXY20301 AXY20202 AXY20302 AXY20203 AXY20205 AXY20303 AXY20305 AXY20101 Spacer — AXY20405 AXY20401 AXY20406 AXY20404 SAFETY NOTES 1. Do not do the following dangerous actions when using the pressure welder. • Insert hand or fingers beneath the pressure plate when operating the lever. • Allow your fingers to get close to moving parts when operating the lever. • Let go of the lever when in progress after pressure welding a connector. (Be sure to keep your hand on the lever all the way to the end. Otherwise the lever might snap back with considerable force.) 2. Secure the pressure welder to the work bench to prevent it from falling over. Also, do not apply excessive force to the lever when pressure welding (such as by applying the full weight of your body). PRESSING PLATE OF PRESSURE WELDING UNIT 1. The pressing plate consists of the pressing plate main unit and MIL/PCB type connector plate. 2. Proceed with the pressure connection of MIL type connectors (AXM1 series) and PCB type connectors (AXP series) with the MIL/PCB connector plate attached to the pressing plate main unit. Use the hexagonal head bolt to mount and remove the MIL/PCB type connector plate. When pressure-welding MIL/PCB type connectors Pressing plate main unit Hexagonal head bolt Resin panel MIL/PCB type connector plate Connectors for industrial equipment DIMENSIONS (Unit: mm) • Pressure welding unit 130 Handle 400 Pressing plate Location for attachment 310 150 • Accessories 18 130 Spacer 130 Attachment Center locator Guide plate Spacer Center locator Guide plate Handle Attachment panasonic-electric-works.net/ac Discontinued as of September 30, 2010 AXY NOTES 1. Sockets setting After covers are temporary fixed with housing (or base), sockets are set at the gutter of center locator. (See Fig. 1) 2. Method of inserting flat cable The guide plate is set at the correct figure of scale, corresponding to the number of contacts (cable width). Then cable is inserted along with the guide until it reaches at the stopper. (See Fig. 2) 3. Pressure connection After adjusting the lower limit of the pressing plate, the connectors should be pressed. Since the guide plate is the stopper, the connectors should be pressed until contacting the pressing plate to the guide plate. In case of PCB types, however, spacers should be placed over the base. (See Fig. 2) 4. Strain relief Regarding MIL type, strain relief should be fixed manually after pressure connection of cables. (See Fig. 3) 5. Be sure to use our pressure welding unit and its accessories when conducting pressure welding. CABLE PRESSURE WELDING MIL type Housing (or base) Guide plate Pressing plate Pressing plate Protector (or cover) Center locator MIL type PCB type Flat cable Center locator PCB type Pressing plate Protector Center locator Fig. 3 Set condition of strain relief Pressing plate Cover Fig. 1 Socket set condition Spacer Fig. 2 Pressure welding condition 1. Cable Cutter 1) Never remove the safety cover 2) Never insert your finger inside the safety cover 3) Use on a stable surface 4) Do not alter this product, or use it for other purposes 2. Pressure Welding Unit 1) Do not place fingers beneath the pressurized plate or in or near moving parts, while the lever is being operated. 2) Lock the unit in place on a workbench or the like. 3) Do not alter this product, or use it for other purposes panasonic-electric-works.net/ac Connectors for industrial equipment SAFETY NOTES FOR SPECIALIZED TOOLS Discontinued as of September 30, 2010 AXH HARNESS FABRICATION FOR FLAT CABLE CONNECTOR NOTES WHEN FABRICATING HARNESSES 1. Common items 1) Select the appropriate connector and cable according to the conditions of use. 2) It is recommended that our cable cutter and pressure welding unit be used. 3) After making the pressure welding, the condition of the connection should be confirmed. 4) Because there are standard terminal layout and reverse terminal layout for PCB type connectors, the connector suitable for the use should be selected. 2. Cable cutter 1) The cable should be cut at right angles to the corresponding length. 2) Use a sharp cutter for making the cut. 3) When setting the cable length, the pressure welding portion and strain relief coil should be considered and set accordingly. For our product, the following cable length is necessary. (For each side) MIL type socket PCB type connector Without strain relief With strain relief Mini-dip type IC type 14 to 20 contacts IC type 24 and 40 contacts 6mm 15mm 7mm 10mm 20mm 3. Cable pressure welding 1) Bring the cable end surface in line with the connector end surface, and set in the groove of the cable guide of the protector. 2) When making a cable pressure welding for a PCB type connector, it is recommended that a spacer be used. This can prevent breakage of the terminals. Example 1: MIL type and MIL type Cable mark Cable mark Example 2: PCB type and PCB type Connectors for industrial equipment Standard terminal layout Reverse terminal layout Cable mark Cable mark Cable mark Cable mark Example 3: PCB type and MIL type Standard terminal layout Reverse terminal layout Cable mark Cable mark Cable mark Cable mark panasonic-electric-works.net/ac Discontinued as of September 30, 2010 AXH HARNESS ASSEMBLY ORDERING INFORMATION Number of contacts for connector cable Left connector type Cable type and length Right connector type AXH AXH connector harness designation Number of contacts for connector or cable Left connector type (see Note 1) Connection of connector and cable (see Note 2) Cable types Standard type: Stranded AWG 28: 1 Fluted type: Stranded AWG 28: 2 Cable mark Front: 1 Rear: 2 Not specified: 3 Cable length (3 digits) Example: 020 for 20 cm (Only 5 cm and longer available.) Right connector type (see Note 1) Connection of connector and cable (see Note 2) Note 1) Connector type MIL type connector PCB type connector Mini-dip type IC type Type Without strain relief With strain relief Srandard terminal layout Reverse terminal layout Reverse terminal layout Order No. M12 M14 P42 P46 P56 Note 2) Connection of connector and cable Order No. 1 2 3 4 5 6 7 8 Left connector Right connector Cable mounting Strain relief Upper side Lower side Without strain relief Upper side Lower side With strain relief We slso accept orders for harnessed products. Call for more information. panasonic-electric-works.net/ac Connectors for industrial equipment Connector
AXM130415 价格&库存

很抱歉,暂时无法提供与“AXM130415”相匹配的价格&库存,您可以联系我们找货

免费人工找货