SAFEGUARDED BY MAGNET
BUILT-IN DETECTOR SWITCH
Magnelimit
• Electrical construction possible at 100V power.
• The built-in magnet safeguards checking of the facility
cover and gate.
• Built-in switch with accurate ON/OFF detection.
• Combination of magnet (support) and limit switch
(detection) saves on both construction and space.
• Two types of contact: 1 Form A (ON when gate is closed)
1 Form B (ON when gate is open.)
• The unit case is available in three colors: Yellow,
brown, and gray.
• The product comes with three different types of weight
sustainability: 1kg, 3kg and 5kg.
PRODUCT TYPE
Product name
Contact construction
Case color
1a
(ON when gate is closed)
Magnelimit 1 Form A
Specifications
Sustainable weight sustainability
Yellow
–
AZC11013Y
Brown
–
AZC11013A
–
AZC11013H
–
AZC11113Y
Brown
–
AZC11113A
Gray
–
AZC11113H
Gray
3kg type (29.4N {3kgf})
(Note: 1)
Yellow
Magnelimit 1 Form B
1b
(ON when gate is open)
Options
Metal plate
Part No.
Packaging
Metal plate (13mm 60mm 1.6mm .512inch 2.362inch .063inch)
AZC1801
Notes:1. The unit comes with an metal plate enclosed.
2. The blister pack type comes with 1 metal plate and 4 screws (2 long, 2 short) enclosed.
3. Weight sustainability also comes in 1kg and 5kg types. Specify when ordering by replacing “3” with “1” for the 1kg type, and “5” for the 5kg type at the end of the part No.
OUTPUT CIRCUIT DIAGRAM
SPECIFICATIONS
1 Form A type
1. Ratings
Load type Resistance load
Rated voltage
5A
5A
5A
125V AC
250V AC
30V DC
Lamp load
Guidance load
1.5A
–
–
3A
3A
1.5A
Notes:1. Inductive load is a minimum 0.4 (AC) and time duration is maximum 7ms (DC).
2. Lamp load has 10 times the inrush current.
3. Minute load ratings: 5mA 6V DC, 1mA 24V DC.
DIMENSIONS
3.43 {350} max.
0.49 {50} min.
1.8mm .071inch max.
0.2 to 0.8
4.0mm .157inch max.
3. Capabilities overview
Electrical
capabilities
Life
Magnet
Pretravel (P.T.) 1.8 max.
Release position (R.P.) 4 max.
4.5
.177
2
.079
Voltage
resistance
Contact distance: AC 1000V/1 min. (initial)
Distance between each pin and uncharged metal parts: AC 2100V/1 min.
Distance between each pin and earth: AC 2100V/1 min.
Mechanical life
Min. 100 thousand times (ON/OFF frequency 60 times/min.)
Electrical life
Min. 50 thousand times (resistance load AC 250V 5A)
Min. 30 thousand times (lamp load AC 125V 1.5V)
ON/OFF frequency 20 times/min.
IP40
–20 to +80°C –4 to 176°F (but not in a frozen environment.)
Max. 95% RH
Mechanical: 60 times/min.
Electrical: 20 times/min.
1kg (9.8N {1kgf}), 3kg (29.4N {3kgf}), 5kg (49N {5kgf})
10/2010
11.8
.465
43.8 1.724
15 .591
9.4
.370 3.8 dia.
.150
Insulation
resistance (initial) Min. 100 (measured at 500V DC insulation resistance)
Protective capabilities
Ambient temperature
Usage
Ambient humidity
conditions
Tolerable operating
frequency
Sustainability
(when using the enclosed metal plate)
mm inch
Magnelimit
2. Switch operating features
Operating force (O.F.) (N{gf})
Return force (R.F.) (N{gf})
Pretravel (P.T.)
Movement differential (M.D.)
Release position (R.P.)
1 Form B type
(72.7) (2.862)
60 2.362
52 –0.15
2.047 –.006
11
.433
.1
R2
31
1.220
7.5
.295
+0.2
4.2—0.1
+.008
.165—.004
R2
.1
38.2
1.504
14.4 dia.
.567
12.7
.500
Metal plate
M3.5 terminal screw
60 2.362
50–0.15
1.969 –.006
13
.512
1.6
.063
4.2 dia.
.165
41
Magnelimit
Metal plate
ATTACHMENT
Unit attachment hole processing dimensions
• Attaching the main unit
1. Using an M4 screw, attach firmly
remembering to employ a washer, etc.
The appropriate torque is 1.18 to 1.47N
(12 to 15kg/cm.)
2. 2. When moveable parts such as the
gate are closed, ensure that the yoke
and metal plate are flush with each other.
Metal plate
Yoke
Moveable side
2-4.3 .170 dia.
or M4 tap
Unless the metal plate and the yoke are
flush with each other, adhesive power
will be lost, and there is a risk that the
switch will not operate.
Fixed side
• Attaching the metal plate
1. Using an M3 dish screw, attach to the side opposite from the yoke. Pay particular
attention that the head of the attached screw does not protrude further than the surface of the metal plate (if using wooden screws, a call of 2.7 is optimum.)
2. If the adhesive side is magnetic (metal plate), the adhesion may prove ineffective.
Further, since the sustainability varies depending on the board thickness and the surface processing (paint, etc.), it is best to check beforehand.
Attachment
screw
52±0.15
2.047 ±.006
Adhesion board hole processing dimensions
50±0.15
1.969±.006
Magnet plate
1
C
2-3.2 .126 dia.
or M3 tap
(Fit a C1 panel to the inlet vent)
SUITABLE WIRING
• Maximum external dimensions upon
completion
Circular: 8mm dia. .315 inch dia. max.
Flat: Lengthwise 9.4mm .370inch max.
(VVF 2 cores, conductor radius 1.6 dia.)
• Wiring processing dimensions
Refer to the diagram below for the wiring
processing dimensions
8 dia. max
.315 dia. max
40
75
1.5
9.4 .370 max
(Lengthwise)
40 1.575
8 to 10
.315 to .394
Flat (VVF 2 cores, conductor radius 1.6 .063 dia)
Circular
WIRING
• Terminal uses a M3.5 angle washer
attachment.
• During wiring work, do not connect the
lead wire directly to the terminal, but via
a crimp contact. However, this excludes
single wiring.
• Wiring by solder should be avoided.
1. Wiring method
Insert a flat screwdriver into the indentation of the product side, and remove the
terminal cover.
Flat screwdriver
Indentation
42
2. Slide the rubber cap and the terminal
cover over the wire, as shown in the
illustration then attach a crimp contact to
the terminal. The torque applied to the
terminal screw should be within the
range of 0.39-0.59 Nm (4-6 kg/cm).
Terminal cover
Rubber cap
3. If using a VVF wire, bend the wire
towards the unit, and once it has taken
the proper shape, install the terminal
cover. After installing the terminal cover,
attach the rubber cap.
10/2010
CAUTIONS FOR USE
• Because the magnelimit is not waterproof, avoid using in areas where it may
be splashed with either water or oil. Also,
avoid using in locations where dust may
accumulate.
• Do not use in atmospheres where the
unit may directly come into contact with
any kind of organic solvent, strong acid
or alkaline liquids, or combustible or corrosive gasses.
• Avoid using in silicon environments
such as organic silicon-based rubber,
solvents, sealants, oil, grease, or wiring.
• The moveable parts on the magnelimit
such as the gates are equipped with a
stopper, so avoid attachments that
require them to bear the full load.
• In order to improve reliability under
actual working conditions, check the
quality under as close to actual working
conditions as possible.
• This magnelimit has a built-in electromagnet. For this reason, take care not to
place floppy disks, magnetic cards, or
other magnetic recording mediums near
the unit, as the data may be corrupted or
lost.
很抱歉,暂时无法提供与“AZC11013H”相匹配的价格&库存,您可以联系我们找货