0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AZC11013H

AZC11013H

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    MAGNELIMIT

  • 数据手册
  • 价格&库存
AZC11013H 数据手册
SAFEGUARDED BY MAGNET BUILT-IN DETECTOR SWITCH Magnelimit • Electrical construction possible at 100V power. • The built-in magnet safeguards checking of the facility cover and gate. • Built-in switch with accurate ON/OFF detection. • Combination of magnet (support) and limit switch (detection) saves on both construction and space. • Two types of contact: 1 Form A (ON when gate is closed) 1 Form B (ON when gate is open.) • The unit case is available in three colors: Yellow, brown, and gray. • The product comes with three different types of weight sustainability: 1kg, 3kg and 5kg. PRODUCT TYPE Product name Contact construction Case color 1a (ON when gate is closed) Magnelimit 1 Form A Specifications Sustainable weight sustainability Yellow – AZC11013Y Brown – AZC11013A – AZC11013H – AZC11113Y Brown – AZC11113A Gray – AZC11113H Gray 3kg type (29.4N {3kgf}) (Note: 1) Yellow Magnelimit 1 Form B 1b (ON when gate is open) Options Metal plate Part No. Packaging Metal plate (13mm  60mm  1.6mm .512inch  2.362inch  .063inch) AZC1801 Notes:1. The unit comes with an metal plate enclosed. 2. The blister pack type comes with 1 metal plate and 4 screws (2 long, 2 short) enclosed. 3. Weight sustainability also comes in 1kg and 5kg types. Specify when ordering by replacing “3” with “1” for the 1kg type, and “5” for the 5kg type at the end of the part No. OUTPUT CIRCUIT DIAGRAM SPECIFICATIONS 1 Form A type 1. Ratings Load type Resistance load Rated voltage 5A 5A 5A 125V AC 250V AC 30V DC Lamp load Guidance load 1.5A – – 3A 3A 1.5A Notes:1. Inductive load is a minimum 0.4 (AC) and time duration is maximum 7ms (DC). 2. Lamp load has 10 times the inrush current. 3. Minute load ratings: 5mA 6V DC, 1mA 24V DC. DIMENSIONS 3.43 {350} max. 0.49 {50} min. 1.8mm .071inch max. 0.2 to 0.8 4.0mm .157inch max. 3. Capabilities overview Electrical capabilities Life Magnet Pretravel (P.T.) 1.8 max. Release position (R.P.) 4 max. 4.5 .177 2 .079 Voltage resistance Contact distance: AC 1000V/1 min. (initial) Distance between each pin and uncharged metal parts: AC 2100V/1 min. Distance between each pin and earth: AC 2100V/1 min. Mechanical life Min. 100 thousand times (ON/OFF frequency 60 times/min.) Electrical life Min. 50 thousand times (resistance load AC 250V 5A) Min. 30 thousand times (lamp load AC 125V 1.5V) ON/OFF frequency 20 times/min. IP40 –20 to +80°C –4 to 176°F (but not in a frozen environment.) Max. 95% RH Mechanical: 60 times/min. Electrical: 20 times/min. 1kg (9.8N {1kgf}), 3kg (29.4N {3kgf}), 5kg (49N {5kgf}) 10/2010 11.8 .465 43.8 1.724 15 .591 9.4 .370 3.8 dia. .150 Insulation resistance (initial) Min. 100 (measured at 500V DC insulation resistance) Protective capabilities Ambient temperature Usage Ambient humidity conditions Tolerable operating frequency Sustainability (when using the enclosed metal plate) mm inch Magnelimit 2. Switch operating features Operating force (O.F.) (N{gf}) Return force (R.F.) (N{gf}) Pretravel (P.T.) Movement differential (M.D.) Release position (R.P.) 1 Form B type (72.7) (2.862) 60 2.362 52 –0.15 2.047 –.006 11 .433 .1 R2 31 1.220 7.5 .295 +0.2 4.2—0.1 +.008 .165—.004 R2 .1 38.2 1.504 14.4 dia. .567 12.7 .500 Metal plate M3.5 terminal screw 60 2.362 50–0.15 1.969 –.006 13 .512 1.6 .063 4.2 dia. .165 41 Magnelimit Metal plate ATTACHMENT Unit attachment hole processing dimensions • Attaching the main unit 1. Using an M4 screw, attach firmly remembering to employ a washer, etc. The appropriate torque is 1.18 to 1.47N (12 to 15kg/cm.) 2. 2. When moveable parts such as the gate are closed, ensure that the yoke and metal plate are flush with each other. Metal plate Yoke Moveable side 2-4.3 .170 dia. or M4 tap Unless the metal plate and the yoke are flush with each other, adhesive power will be lost, and there is a risk that the switch will not operate. Fixed side • Attaching the metal plate 1. Using an M3 dish screw, attach to the side opposite from the yoke. Pay particular attention that the head of the attached screw does not protrude further than the surface of the metal plate (if using wooden screws, a call of 2.7 is optimum.) 2. If the adhesive side is magnetic (metal plate), the adhesion may prove ineffective. Further, since the sustainability varies depending on the board thickness and the surface processing (paint, etc.), it is best to check beforehand. Attachment screw 52±0.15 2.047 ±.006 Adhesion board hole processing dimensions 50±0.15 1.969±.006 Magnet plate 1 C 2-3.2 .126 dia. or M3 tap (Fit a C1 panel to the inlet vent) SUITABLE WIRING • Maximum external dimensions upon completion Circular: 8mm dia. .315 inch dia. max. Flat: Lengthwise 9.4mm .370inch max. (VVF 2 cores, conductor radius 1.6 dia.) • Wiring processing dimensions Refer to the diagram below for the wiring processing dimensions 8 dia. max .315 dia. max 40 75 1.5 9.4 .370 max (Lengthwise) 40 1.575 8 to 10 .315 to .394 Flat (VVF 2 cores, conductor radius 1.6 .063 dia) Circular WIRING • Terminal uses a M3.5 angle washer attachment. • During wiring work, do not connect the lead wire directly to the terminal, but via a crimp contact. However, this excludes single wiring. • Wiring by solder should be avoided. 1. Wiring method Insert a flat screwdriver into the indentation of the product side, and remove the terminal cover. Flat screwdriver Indentation 42 2. Slide the rubber cap and the terminal cover over the wire, as shown in the illustration then attach a crimp contact to the terminal. The torque applied to the terminal screw should be within the range of 0.39-0.59 Nm (4-6 kg/cm). Terminal cover Rubber cap 3. If using a VVF wire, bend the wire towards the unit, and once it has taken the proper shape, install the terminal cover. After installing the terminal cover, attach the rubber cap. 10/2010 CAUTIONS FOR USE • Because the magnelimit is not waterproof, avoid using in areas where it may be splashed with either water or oil. Also, avoid using in locations where dust may accumulate. • Do not use in atmospheres where the unit may directly come into contact with any kind of organic solvent, strong acid or alkaline liquids, or combustible or corrosive gasses. • Avoid using in silicon environments such as organic silicon-based rubber, solvents, sealants, oil, grease, or wiring. • The moveable parts on the magnelimit such as the gates are equipped with a stopper, so avoid attachments that require them to bear the full load. • In order to improve reliability under actual working conditions, check the quality under as close to actual working conditions as possible. • This magnelimit has a built-in electromagnet. For this reason, take care not to place floppy disks, magnetic cards, or other magnetic recording mediums near the unit, as the data may be corrupted or lost.
AZC11013H 价格&库存

很抱歉,暂时无法提供与“AZC11013H”相匹配的价格&库存,您可以联系我们找货

免费人工找货