1433
FIBER
SENSORS
* Refer to our website for details of product.
Compact Size Horizontal Type
HL
RoHS compliance
(AZH) Micro Limit Switch
Related Information
*1
■■General terms and conditions.............. F-3
LASER
SENSORS
*1 AZH10 only
Features
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
• Superior environmental resistance
(Die casting case type)
• Standardized connector type
• Lineup includes bifurcated (twin
contact) type as well as standard load
type
• Economical plastic case type
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
panasonic.net/id/pidsx/global
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
Compact, high-performance limit switch
with superior environmental resistance
PRODUCT TYPE
Body
ENERGY
MANAGEMENT
SOLUTIONS
Type
FA COMPONENTS
Die casting case
Screw terminal type
Standard
Bifurcated
Connector type
Bifurcated
Plastic case
Screw terminal type
Standard
Bifurcated
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Timers
Time Switches
Counters
Hour Meters
Options
Limit Switches
Temperature
Controllers
Solenoids
Fan Motors
Selection
Guide
SL
HL
QL
Magnelimit
Actuator
Model No.
Model No.
Model No.
Model No.
Model No.
Push plunger
Common to panel mount push plunger
AZH1001
AZH1201
Roller plunger
Common to panel mount roller plunger
AZH1002
AZH1202
Common to panel mount cross roller plunger
AZH1003
AZH1203
Panel mount push plunger
AZH2031
AZH2231
AZH2331
AZH1031
AZH1231
Panel mount roller plunger
AZH2032
AZH2232
AZH2332
AZH1032
AZH1232
Panel mount cross roller plunger
AZH2033
AZH2233
AZH2333
AZH1033
AZH1233
Sealed push plunger
AZH2011
AZH2211
AZH2311
AZH1011
AZH1211
Sealed roller plunger
AZH2012
AZH2212
AZH2312
AZH1012
AZH1212
Sealed cross roller plunger
AZH2013
AZH2213
AZH2313
AZH1013
AZH1213
Short roller lever
AZH2041
AZH2241
AZH2341
AZH1041
AZH1241
Roller lever
AZH2021
AZH2221
AZH2321
AZH1021
AZH1221
One-way short roller lever
AZH2044
AZH2244
AZH2344
AZH1044
AZH1244
One-way roller lever
AZH2024
AZH2224
AZH2324
AZH1024
AZH1224
Flexible
―
―
―
AZH1066
AZH1266
Cross roller plunger
HL (AZH) Micro Limit Switch
1434
Options
FIBER
SENSORS
Specifications
Product
Pin arrangement
Cable connector cord
AC
Type
Straight
Angle
Core No.
Color of wire
Conductor
Length of cable
4
Brown, White,
Blue, Black
0.5 mm2 0.75 × 10-3 in2
(Circumference:
ø6.5 ø0.256 approx.)
3m
9.843 ft
Application
All connector type
Model No.
LASER
SENSORS
AZH28113
PHOTOELECTRIC
SENSORS
AZH28133
CAUTIONS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Common for all types
• This limit switch is designed under the premise that it will be used in a standard industrial device. Accordingly, there are
limits as to what can be tolerated if used outdoors or where water and oil, etc., may get on the device.
The following table indicates how much water and oil can be withstood (classification of protective structure).
Plastic case (AZH1*)
Protective
classification
Testing method
Limits on use
MICRO
PHOTOELECTRIC
SENSORS
Die casting case (AZH2*)
IP64
IP67
No harmful effect when sprayed with water for 10 minutes from all
angles.
Water does not enter product after immersion in water 1 m 3.281 ft
deep for 30 minutes.
Cannot be used outdoors or in a place where water and oil, etc., will
continually contact the device.
Cannot be used outdoors where it can be rained on directly and
cannot be used submersed in water or in oil, etc.
Note: Although, initially, the protective classification complies under the testing above, due consideration must be taken because great differences may
result depending on factors such as duration of operation, installation method, and environment.
• The internal mechanism will break if the actuator is moved beyond its Total-travel (T.T.). Always use within the T.T.
Die casting case
• Do not expose HL limit switch to hot water (over 60 °C
+140 °F) and in a water vapor environment.
• Avoid the place where organic solvents, strong acid,
strong alkali liquid and vapor may attach to the products
directly. Prevent using the HL limit switch in place where
inflammable or corrosive gas will be generated.
• Do not change the operating position by bending the
actuator.
• Use within an ambient temperature of –10 to 80 °C. +14
to +176 °F (However, do not allow it to freeze.)
• If O.T. is too big, the life of limit switch will be shortened
by switching friction.
Use it with enough margin of O.T. 70 % of O.T. standard
value will be good.
• Attach the terminal cover securely to the body with the
metal stop latch to the projection of the body.
• Confirmation test in the actual application is highly
recommended.
• Do not use the switch in a silicon atmosphere. Care
should be taken where organic silicon rubber, adhesive,
seling material, oil, grease or lead wire generates silicon.
• This is designed to use inside. When used outdoors (in
places where there is exposure to direct sunlight or rain
such as in multistory car parks) or in environments where
ozone is generated, the influence of these environments
cause deterioration of the rubber material and damage
for the products.
• Avoid use in excessively dusty environments where
actuator operation would be hindered.
Plastic case
• Do not use in water or oil.
Do not place the switch where it is always exposed to
water or dust splash.
• Do not expose HL limit switch to hot water (over 60 °C
+140 °F) and in a water vapor environment.
• Avoid the place where organic solvents, strong acid,
strong alkali liquid and vapor may attach to the products
directly. Prevent using the HL limit switch is place where
inflammable or corrosive gas will be generated.
• Do not change the operating position by bending the
actuator.
• Use within an ambient temperature of –10 to 80 °C. +14
to +176 °F (However, do not allow it to freeze.)
• If O.T. is too big, the life of limit switch will be shortened
switching friction. Use it with enough margin of O.T. 70 %
of O.T. standard value will be good for use.
• Attach the terminal cover securely to the body to the
extent you can identify the clicking or locking sound.
• A confirmation test in the actual application is highly
recommended.
• Do not use the switch in a silicon atmosphere. Case
should be taken where organic silicon rubber, adhesive,
sealing material, oil, grease or lead wire generates
silicon.
• This is designed to use inside. When used outdoors (in
places where there is exposure to direct sunlight or rain
such as in multistory car parks) or in environments where
ozone is generated, the influence of these environments
cause deterioration of the rubber material and damage
for the products.
• Avoid use in excessively dusty environments
where actuator operation would be hindered.
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Timers
Time
Switches
Counters
Hour
Meters
Options
Limit
Switches
Temperature
Controllers
Solenoids
Fan
Motors
Selection
Guide
SL
HL
QL
Magnelimit
很抱歉,暂时无法提供与“AZH2321”相匹配的价格&库存,您可以联系我们找货