For small diameter tubes
Optical Bubble Sensor
BE-A SERIES
Fits perfectly with applicable tube sizes!
Detects liquid and air bubbles
without fail!
Tube outer diameter
ø2
mm
ø0.078 in
Tube outer diameter
ø3
mm
ø0.125 in
Tube outer diameter
ø4
mm
ø0.156 in
2019.05
industrial.panasonic.com/ac/e/
Experience its ease of use!
Optical bubble sensor is handy, simple, and precise!
New proposals
for ease of use
One-touch attachment
ø2 mm ø0.078 in
tube type
Simply attach the sensor with your hand!
Hassle-free one-touch attachment without using tools!
In the case of BE-A201(P) / BE-A301(P)
In the case of BE-A401(P)
ø4 tube
Push down
Pull
Pull
Insert
Tube
●Push down the tube into the sensor.
*Tube: Equivalent to PFA
New proposals
for ease of use
●Stretch the tube and insert it into the sensor.
*ø4 tube: Equivalent to flexible PVC
For small diameter tubes
For ø2 mm, ø3 mm, ø4 mm tubes
Perfect fit into applicable tubes without obstructing flow rate.
Compatible with tubes in inch size
ø2 mm tube type
BE-A201(P)
New proposals
for ease of use
ø3 mm tube type
BE-A301(P)
High speed response time
ø4 mm tube type
:
BE-A201 (NPN output type)
BE-A201P (PNP output type)
Applicable tube : Transparent resin tube
(Equivalent to PFA)
Outer diameter : ø2 mm ±0.2 mm
ø0.078 in ±0.008 in
Inner diameter : ø1 mm ±0.2 mm
ø0.039 in ±0.008 in
Output operation: Liquid-absent-ON / Liquid-present-ON
(equipped with two outputs)
BE-A401(P)
New proposals
for ease of use
Model No.
Ultra compact
New proposals
for ease of use
For a wide-range of
power supply voltages
High speed detection
Fingertip size
5 to 24 V DC compliant
0.8 mm 0.032 in air gaps are reliably
detected by optical technology at a
response time of 20 μs*.
Ideal for traceability of the analysis process.
Allows for installation in a narrow space.
Allows for direct power supply from
PC board.
0.8 mm
0.032 in
New proposals
for ease of use
Built-in Amplifier
No requirement of
sensitivity adjustment
Can be used immediately after installation
by built-in amplifier.
Equipped with two outputs,
Liquid-absent-ON and Liquid-present-ON.
*Refer to the specifications for detection conditions,
BE-A201(P) has a response time of 30 μs.
2
Allows for
close proximity
attachment
Staggered pattern
Parallel pattern
(10 mm 0.394 in pitch)
(15.5 mm 0.610 in pitch)
ø3 mm ø0.125 in
ø4 mm ø0.156 in
tube type
Model No.
:
tube type
BE-A301 (NPN output type)
BE-A301P (PNP output type)
Model No.
Applicable tube : Transparent resin tube
(Equivalent to PFA)
Outer diameter: ø3 mm ±0.2 mm
ø1/8 in ±0.008 in
Inner diameter: ø2 mm ±0.2 mm
ø1/16 in ±0.008 in
Output operation: Liquid-absent-ON / Liquid-present-ON
(equipped with two outputs)
:
BE-A401 (NPN output type)
BE-A401P (PNP output type)
Applicable tube : Transparent resin tube
(equivalent to flexible PVC)
Outer diameter: ø4 mm ±0.15 mm
ø5/32 in ±0.006 in
Inner diameter: ø2.4 mm ±0.1 mm
ø3/32 in ±0.004 in
Output operation: Liquid-absent-ON / Liquid-present-ON
(equipped with two outputs)
Applications
Liquid dispensing
instrument
Clinical laboratory
instrument
BE-A series
Empty detection
inside the tank
BE-A series
Air bubble
detection
after pumping
BE-A series
Air bubble detection
before liquid dispensing
Precise liquid
dispensing
Reagent/
cleaning
fluid tank
To
dispensing
nozzle
3
BE-A SERIES
Type
NPN output
PNP output
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C
+73.4 °F.
2) Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note
that this product cannot sense very small air bubbles or water drops. Refer to the figure 1 and 2.
3) Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly.
4) When using a tube out of specifications or it doesn’t have a smooth surface, please test sensing on the actual machine
before use.
5) Actual response time may differ from specification (typical example using applicable tube) due to dimension, light
transmission or surface state of test tube in use.
6) Liquid being detected should also be kept within the rated ambient temperature range.
7) Confirm that the power supply voltage at the end of cable is more than 4.5 V when using an extension of over 20 m 65.167 ft.
Bubble
ø2.5 mm ø0.098 in
cable 1 m 3.280 ft long
4-core × 0.09 mm 2
(AWG28)
insulator diameter:
ø0.66 mm ø0.026 in
2019.05
industrial.panasonic.com/ac/e/
©Panasonic Coporation 2019
Droplet
fig.2
8.3
0.327
Operation
indicator
(Orange)
15.5
0.610
7
0.276
Beam axis
ø2.5 mm ø0.098 in
cable 1 m 3.280 ft long
4-core × 0.09 mm 2
(AWG28)
insulator diameter:
ø0.66 mm ø0.026 in
Right side dimension
(in common)
Tube holder
9
0.354
2 × ø3.5 ø0.138
mounting holes
20
0.787
Beam axis
●If you have any question about Optical Bubble Sensor,
please contact us by E-mail .
No.PCE-BEA-1 May, 2019
14.7
0.579
8.3
0.327
9
0.354
7
0.276
Tube holder
3.5
0.138
15.5
0.610
2
0.079
ø2.5 mm ø0.098 in
cable 1 m 3.280 ft long
4-core × 0.09 mm 2
(AWG28)
insulator diameter:
ø0.66 mm ø0.026 in
20
0.787
Beam axis
Operation
indicator
(Orange)
2 × ø3.5 ø0.138
mounting holes
2
0.079
9
0.354
7
0.276
Bubble
fig.1
BE-A401(P)
14.2
0.559
8.3
0.327
2 × ø3.5 ø0.138
mounting holes
Tube holder
3.5
0.138
15.5
0.610
Air
The CAD data can be downloaded from our website.
BE-A301(P)
Operation
indicator
(Orange)
Liquid
Air gap
Liquid
DIMENSIONS (Unit: mm in)
BE-A201(P)
Tube
16.5
0.650
2.5
0.098
10
0.394
Vibration resistance
Shock resistance
Emitter element
Material
Cable
Cable extension (Note 7)
Clamping torque
Weight
EMC Directive, RoHS Directive
0.8 mm 0.032 in or more
Liquid (Note 3)
ø2 mm ±0.2 mm ø0.078 in ±0.008 in
ø3 mm ±0.2 mm ø1/8 in ±0.008 in
ø4 mm ±0.15 mm ø5/32 in ±0.006 in
ø1 mm ±0.2 mm ø0.039 in ±0.008 in
ø2 mm ±0.2 mm ø1/16 in ±0.008 in
ø2.4 mm ±0.1 mm ø3/32 in ±0.004 in
Transparent resin tube (equivalent to flexible PVC)
Transparent resin tube (equivalent to PFA)
5 to 24 V DC ±10 % Ripple P-P 10 % or less
15 mA or less
NPN open-collector transistor
PNP open-collector transistor
•Maximum sink current: 50 mA
•Maximum source current: 50 mA
•Applied voltage: 30 V DC or less (between output and 0 V)
•Applied voltage: 30 V DC or less (between output and + V)
•Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA)
•Residual voltage: 2 V or less (source current at 50 mA) 1 V or less (source current at 16 mA)
Switchable either Liquid-absent-ON or Liquid-present-ON
Incorporated
30 μs or less
20 μs or less
80 μs or less
Orange LED (lights up with absent liquid)
Power supply reverse polarity protection , Output reverse polarity protection
IP40 (IEC)
-25 to +55 °C -13 to +131 °F (No dew condensation or icing allowed), Storage: -30 to +80 °C -22 to +176 °F
35 to 85 % RH, Storage: 35 to 85 % RH
Fluorescent light: 1,000 ℓx at the light-receiving face
1,000 V AC for between one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or maximum acceleration
49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration in X, Y, and Z directions three times each
Infrared LED(Peak emission wavelength: 855 nm 0.034 mil, non-modulated)
Enclosure: PBT, Tube holder: Polyamide, Indicator: Polycarbonate
0.09 mm2 4-core cabtyre cable 1 m 3.280 ft
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
0.5N•m or less
Net weight: 15 g approx., Gross weight: 25 g approx.
14.8
0.583
Environmental resistance
Output operation
Short-circuit protection
Response time When detecting bubble
(Note 5)
When detecting liquid
Operation indicator
Protection circuits
Protection
Ambient temperature (Note 6)
Ambient humidity
Ambient illuminance
Voltage withstandability
Insulation resistance
for ø4 mm ø0.156 in tube
BE-A401
BE-A401P
20
0.787
Output
(Incorporated with 2 outputs)
for ø3 mm ø0.125 in tube
BE-A301
BE-A301P
2
0.079
Regulatory compliance
Detectable air gap (Note 2)
Sensing object
Applicable tube dia. Outer dia.
(Note 4)
Inner dia.
Applicable tube type (Note 4)
Supply voltage
Current consumption
for ø2 mm ø0.078 in tube
BE-A201
BE-A201P
3.5
0.138
Item
Model No.
SPECIFICATIONS
Operation
indicator ø5.2
(Orange) ø0.205
3
0.118
USA customers
: usa-bmpj@ml.jp.panasonic.com
EURO customers : euro-bmpj@ml.jp.panasonic.com
Panasonic Corporation
Industrial Device Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
Specifications are subject to change without notice.
很抱歉,暂时无法提供与“BE-A201P”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+285.05520
- 200+113.74560
- 500+109.94400
- 1000+108.06480