1011
FIBER
SENSORS
Sensor-PLC Connection System
SC SERIES
Related Information
■■General terms and conditions.............. F-7
■■LS-500 / LS-400 / DPS-400 / GA-311..........P.241~ / P.253~ / P.767~ / P.875~
■■FX-500 / FX-300 / FX-410 / FX-311.....P.73~ / P.139~ / P.167~ / P.183~
■■General precautions...................... P.1501
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
SC-MIL/T1J(-P)
SC-T8J(-P) only
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
• Never use this product in a device for personnel
protection.
• In case of using devices for personnel protection,
use products which meet laws and standards,
such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
panasonic.net/id/pidsx/global
Up to 16 I/O devices can be connected at once using MIL
connectors
ORDER GUIDE
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Designation
Appearance
Model No.
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
Description
Main unit
SC-MIL
The MIL connector allows up to 16 input / output device connections to a PLC or
custom circuit board, in a single step.
Separate unit
SC-MIL-S
Distributed installations are possible through the use of a main unit and MIL
connectors.
1-channel
connector
input extension
unit
SC-T1J
For NPN output devices
SC-T1J-P
For PNP output devices
8-channel
connector
input extension
unit
SC-T8J
For NPN output devices
SC-T8J-P
For PNP output devices
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Upper
Communication Unit
MIL Connector
Plug-in
8-channel
connector
I/O mixed
extension
unit
Allows the connection of input devices, such as
sensors or switches.
Incorporates a power indicator and input signal
indicators (8 ch).
SC-TP8J
Allows the connection of a variety of input and output devices.
This unit does not contain input / output signal indicators.
CN-70
This one-touch connector is used to connect the main unit to the following devices:
The FX-501/502/301/305/311 and FX-411/412 fiber sensor, the LS-401/403 laser
sensor, digital pressure sensor DPS-401/402, the GA-311 compact inductive
proximity sensor, the FX-CH(-P) bank selection unit and the SC-T1J(-P)
1-channel connector input extension unit. (Note 1, 2)
SC
Non-line
connector
Allows the connection of input device, such as sensor
or switch.
Incorporates a power indicator and an input signal
indicator (1 ch).
Notes: 1) The non-line connector now can be used with 4-pin types, such as the FX-305 and LS-401, since its production run starting in August 2004.
2) Only the output 1 (OUT1) for the FX-502/305, LS-401/403 and DPS-401/402 can be output from the SC-MIL.
There is no connection for output 2 (OUT2).
SC SERIES
Sensor-PLC Connection System
1012
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
Designation
Appearance
Model No.
SL-CP1 (White)
10 pcs. per set
4-pin type snap
male
connector
(Note)
SL-CP2 (Black)
10 pcs. per set
Description
For 0.08 to 0.2 mm2
(Conductor cross-section area)
Wire diameter:
ø0.7 to ø1.2 mm ø0.028 to ø0.047 in
For 0.3 mm
(Conductor cross-section area)
Wire diameter:
ø1.1 to ø1.6 mm ø0.043 to ø0.063 in
2
For 0.5 mm
2
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Snap male connectors are utilized to connect input /
output devices to both the 1-channel and the
8-channel connector input units, as well as to the
8-channel connector combined input / output unit.
The 1-channel connector input extension unit
includes one SL-CP1.
SL-CP3 (Greenish blue) (Conductor cross-section area)
10 pcs. per set
MS-DIN-E
End plates
2 pcs. per set
Connector end
caps
PRESSURE /
FLOW
SENSORS
PARTICULAR
USE
SENSORS
After the SC series units have been attached to the DIN rail, all these devices must be
secured firmly together by placing end plates at each of the ends and sandwiching the
devices in between. Ensure that these end plates are used for this purpose.
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
OPTIONS
MEASUREMENT
SENSORS
Model No.
SC-MA1
10 sheets per set
SC-PK
8 pcs. per set
Description
STATIC
ELECTRICITY
PREVENTION
DEVICES
Index seals
• SC-MA1
Numbering plate
An identifier for each connector should be marked on each
seal, then the seals should be applied to the numbering plates
attached to both the 8-channel connector input unit and the 8channel connector input / output unit.
Utilized to protect the unconnected ends of connectors, for
both the 8-channel connector input unit and the 8-channel
connector input / output unit.
LASER
MARKERS
PLC
T
T IT
T IT L
T IT L E/
T IT L E/
T IT L E/
T IT L E/
T IT L E/
T IT L E/
T IT LE E/
IT L
L E/ /
E
/
Index seals
LIGHT
CURTAINS /
SAFETY
COMPONENTS
INDUCTIVE
PROXIMITY
SENSORS
Wire diameter:
ø1.7 to ø2.5 mm ø0.067 to ø0.098 in
Note: Exclusive pliers are also available. Refer to the sensor & wire-saving link system S-LINK pages for details.
Designation
AREA
SENSORS
/
E
ITL
T
SC-T8J(-P)
SC-TP8J
Index seals
SC-MA1
Connector end caps
• SC-PK
Connector end caps
SC-PK
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
SC-T8J(-P)
SC-TP8J
Upper
Communication
Unit
MIL Connector
Plug-in
SC
1013
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
Sensor-PLC Connection System
SPECIFICATIONS
Sensor units
Type
Item
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
Main unit
Separate unit
SC-MIL
SC-MIL-S
12 to 24 V DC ±10 % (Note 2)
In combination with SC-TP8J, the unit can be also
used with a power supply of 5 to 24 V DC ±10 %.
Depends on the supply voltage from SC-MIL
2 A or less
Same as maximum permissible current
consumption of all units connected to SC-MIL.
1 A or less
Same as maximum permissible current
consumption of all units connected to SC-MIL-S.
Model No.
Supply voltage
Allowable through current
(Note 3)
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
SC SERIES
Connectable up to 16 channels
The signal from up to 16th point (counting from unit adjacent to SC-MIL) of all units connected to SC-MIL is transferred.
However, the signal thereafter is not transferred. Note that SC-MIL and SC-MIL-S do not occupy any signal point.
Signal channel No.
Max. distance between units
10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together)
Pollution degree
3 (Industrial environment)
Ambient temperature
–10 to +45 °C +14 to +113 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Material
Enclosure: Heat-resistant ABS
Weight
Dimensions
Net weight: 25 g approx.
Net weight: 20 g approx.
W16 × H39.5 × D85 mm W0.630 × H1.555 × D3.346 in
W20.15 × H39.5 × D85 mm W0.793 × H1.555 × D3.346 in
Accessory
Connector protection seal: 1 pc.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2)
The plug-in sensor main unit SC-MIL incorporates a cable lead-out connector in addition to the MIL connector, which allows to receive the supply voltage
from the separate power supply.
3)
Same as maximum permissible current consumption of all units connected to SC-MIL. When either the permissible current amount of power supply unit or
the permissible current amount of cable to be connected is 2 A or less, adjust the current to the smallest value.
Applicable unit of non-line connector
Non-line connector
Type
CN-70
Designation
Model No.
Description
Item
Applicable unit
Refer to the list of “Applicable unit of non-line connector”
SC-T1J
For NPN output devices
FA
COMPONENTS
Supply voltage
Depends on the supply voltage from SC-MIL
SC-T1J-P
For PNP output devices
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Upper
Communication
Unit
MIL Connector
Plug-in
SC
Model No.
Non-line connector
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
1-channel input
extension units
FX-501/502
For NPN output devices
1 channel
FX-501P/502P
For PNP output devices
Ambient temperature
–10 to +45 °C +14 to +113 °F
(No dew condensation or icing allowed)
Storage: –20 to +70 °C – 4 to +158 °F
FX-301(B/G/H)
FX-301-HS
For NPN output devices
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
FX-301(B/G/H)P
FX-301P-HS
For PNP output devices
FX-305
For NPN output devices
FX-305P
For PNP output devices
FX- 411(B/G)
FX- 412(B/G)
For NPN output devices
FX- 411(B/G)P
For PNP output devices
FX-311(B/G)
For NPN output devices
FX-311(B/G)P
For PNP output devices
FX-301-F
For NPN output devices
FX-301P-F
For PNP output devices
LS- 501
For NPN output devices
LS- 501P
For PNP output devices
LS- 401/403
For NPN output devices
LS- 401P
For PNP output devices
Digital pressure sensor
DPS-401/402
For NPN output devices
Compact inductive
proximity sensor
GA-311
For NPN output devices
FX-CH
For NPN input devices
FX-CH-P
For PNP input devices
Supply current for units
Signal channel No.
100 mA or less
Material
Enclosure: ABS
Weight
Net weight: 4 g approx.
Digital fiber sensors
(Note)
Notes: 1) Where measurement conditions have not been specified precisely,
the conditions used were an ambient temperature of +20 °C +68 °F.
2)
The non-line connector now can be used with 4-pin types, such as the
FX-305 and LS-401, since its production run starting in August 2004.
Manually set
fiber sensors
Digital fiber sensors for
leak detection fiber / liquid
detection fiber
Digital laser sensors
(Note)
Bank selection unit
Note: O
nly the output 1 (OUT1) for the FX-502/305, LS-401/403 and
DPS-401/402 can be output from the SC-MIL. There is no connection
for output 2 (OUT2).
Sensor-PLC Connection System
SC SERIES
1014
SPECIFICATIONS
FIBER
SENSORS
Connector extension units
LASER
SENSORS
Connector input extension unit
Type
Item
Model No.
For NPN output devices
For PNP output devices
1 channel
8 channels
1 channel
8 channels
8 channels
SC-T1J
SC-T8J
SC-T1J-P
SC-T8J-P
SC-TP8J
Supply voltage
Current consumption
(Note 3)
Connector I/O
mixed extension unit
12 to 24 V DC ±10 %
5 to 24 V DC ±10 % (Note 2)
20 mA or less
60 mA or less
20 mA or less
60 mA or less
(when all indicators light up) (when all indicators light up) (when all indicators light up) (when all indicators light up)
7 mA or less
Signal channel No.
1 input
8 inputs (Note 4)
1 input
Connectable device
NPN open-collector, or
DC 2-wire output type
sensor, or switch etc.
NPN open-collector
output sensor or switch
etc. (Note 6)
PNP open-collector, or
DC 2-wire output type
sensor, or switch etc.
PNP open-collector
Commercially available
output sensor or switch I/O device including DC
etc. (Note 6)
2-wire type sensor
100 mA or less
800 mA or less
(At a total of 8 channels)
100 mA or less
800 mA or less
800 mA or less
(At a total of 8 channels) (At a total of 8 channels)
Supply current for units
(Note 7)
Power indicator
Input indicator
Ambient temperature
8 inputs / outputs (Note 5)
Green LED (Lights up when the power is ON)
Green LED [SC-T1J(-P): 1 No., SC-T8J(-P): 8 Nos.] (Lights up when each channel input is ON)
–
–10 to +45 °C +14 to +113 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Material
Net weight
8 inputs (Note 4)
40 g approx.
10 g approx.
40 g approx.
Dimensions
W10 × H27.5 × D64.5 mm W29.15 × H39.65 × D85 mm W10 × H27.5 × D64.5 mm W29.15 × H39.65 × D85 mm W29.15 × H39.65 × D85 mm
W0.394 × H1.083 × D2.539 in W1.148 × H1.561 × D3.347 in W0.394 × H1.083 × D2.539 in W1.148 × H1.561 × D3.347 in W1.148 × H1.561 × D3.347 in
Accessories
SL-CP1 (Snap male connector): 1 pc.
Index seal: 1 pc.
SL-CP1 (Snap male connector): 1 pc.
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Enclosure: Heat-resistant ABS
10 g approx.
PHOTOELECTRIC
SENSORS
Index seal: 1 pc.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) It depends on the power supply from SC-MIL.
3) The current consumption and input current of the input unit connected are not included.
4) The signal for 8 channels is occupied regardless of number of input units connected.
5) The signal for 8 channels is occupied regardless of number of I/O units connected.
6) DC 2-wire type sensor and switch etc. cannot be connected.
7) Set the maximum current passing through input / output line to 50 mA or less.
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Upper
Communication
Unit
MIL Connector
Plug-in
SC
很抱歉,暂时无法提供与“CN-70”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+142.422301+18.39958