CN-70

CN-70

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    NON-LINE QD CONN FOR FX-300 SER

  • 数据手册
  • 价格&库存
CN-70 数据手册
1011 FIBER SENSORS Sensor-PLC Connection System SC SERIES Related Information ■■General terms and conditions.............. F-7 ■■LS-500 / LS-400 / DPS-400 / GA-311..........P.241~ / P.253~ / P.767~ / P.875~ ■■FX-500 / FX-300 / FX-410 / FX-311.....P.73~ / P.139~ / P.167~ / P.183~ ■■General precautions...................... P.1501 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive SC-MIL/T1J(-P) SC-T8J(-P) only MICRO PHOTOELECTRIC SENSORS AREA SENSORS • Never use this product in a device for personnel protection. • In case of using devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS panasonic.net/id/pidsx/global Up to 16 I/O devices can be connected at once using MIL connectors ORDER GUIDE WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Designation Appearance Model No. STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS Description Main unit SC-MIL The MIL connector allows up to 16 input / output device connections to a PLC or custom circuit board, in a single step. Separate unit SC-MIL-S Distributed installations are possible through the use of a main unit and MIL connectors. 1-channel connector input extension unit SC-T1J For NPN output devices SC-T1J-P For PNP output devices 8-channel connector input extension unit SC-T8J For NPN output devices SC-T8J-P For PNP output devices PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Upper Communication Unit MIL Connector Plug-in 8-channel connector I/O mixed extension unit Allows the connection of input devices, such as sensors or switches. Incorporates a power indicator and input signal indicators (8 ch). SC-TP8J Allows the connection of a variety of input and output devices. This unit does not contain input / output signal indicators. CN-70 This one-touch connector is used to connect the main unit to the following devices: The FX-501/502/301/305/311 and FX-411/412 fiber sensor, the LS-401/403 laser sensor, digital pressure sensor DPS-401/402, the GA-311 compact inductive proximity sensor, the FX-CH(-P) bank selection unit and the SC-T1J(-P) 1-channel connector input extension unit. (Note 1, 2) SC Non-line connector Allows the connection of input device, such as sensor or switch. Incorporates a power indicator and an input signal indicator (1 ch). Notes: 1) The non-line connector now can be used with 4-pin types, such as the FX-305 and LS-401, since its production run starting in August 2004. 2) Only the output 1 (OUT1) for the FX-502/305, LS-401/403 and DPS-401/402 can be output from the SC-MIL. There is no connection for output 2 (OUT2). SC SERIES Sensor-PLC Connection System 1012 ORDER GUIDE FIBER SENSORS LASER SENSORS Designation Appearance Model No. SL-CP1 (White) 10 pcs. per set 4-pin type snap male connector (Note) SL-CP2 (Black) 10 pcs. per set Description For 0.08 to 0.2 mm2 (Conductor cross-section area) Wire diameter: ø0.7 to ø1.2 mm ø0.028 to ø0.047 in For 0.3 mm (Conductor cross-section area) Wire diameter: ø1.1 to ø1.6 mm ø0.043 to ø0.063 in 2 For 0.5 mm 2 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Snap male connectors are utilized to connect input / output devices to both the 1-channel and the 8-channel connector input units, as well as to the 8-channel connector combined input / output unit. The 1-channel connector input extension unit includes one SL-CP1. SL-CP3 (Greenish blue) (Conductor cross-section area) 10 pcs. per set MS-DIN-E End plates 2 pcs. per set Connector end caps PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS After the SC series units have been attached to the DIN rail, all these devices must be secured firmly together by placing end plates at each of the ends and sandwiching the devices in between. Ensure that these end plates are used for this purpose. SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS OPTIONS MEASUREMENT SENSORS Model No. SC-MA1 10 sheets per set SC-PK 8 pcs. per set Description STATIC ELECTRICITY PREVENTION DEVICES Index seals • SC-MA1 Numbering plate An identifier for each connector should be marked on each seal, then the seals should be applied to the numbering plates attached to both the 8-channel connector input unit and the 8channel connector input / output unit. Utilized to protect the unconnected ends of connectors, for both the 8-channel connector input unit and the 8-channel connector input / output unit. LASER MARKERS PLC T T IT T IT L T IT L E/ T IT L E/ T IT L E/ T IT L E/ T IT L E/ T IT L E/ T IT LE E/ IT L L E/ / E / Index seals LIGHT CURTAINS / SAFETY COMPONENTS INDUCTIVE PROXIMITY SENSORS Wire diameter: ø1.7 to ø2.5 mm ø0.067 to ø0.098 in Note: Exclusive pliers are also available. Refer to the sensor & wire-saving link system S-LINK pages for details. Designation AREA SENSORS / E ITL T SC-T8J(-P) SC-TP8J Index seals SC-MA1 Connector end caps • SC-PK Connector end caps SC-PK HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS SC-T8J(-P) SC-TP8J Upper Communication Unit MIL Connector Plug-in SC 1013 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS Sensor-PLC Connection System SPECIFICATIONS Sensor units Type Item PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES Main unit Separate unit SC-MIL SC-MIL-S 12 to 24 V DC ±10 % (Note 2) In combination with SC-TP8J, the unit can be also used with a power supply of 5 to 24 V DC ±10 %. Depends on the supply voltage from SC-MIL 2 A or less Same as maximum permissible current consumption of all units connected to SC-MIL. 1 A or less Same as maximum permissible current consumption of all units connected to SC-MIL-S. Model No. Supply voltage Allowable through current (Note 3) PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS SC SERIES Connectable up to 16 channels The signal from up to 16th point (counting from unit adjacent to SC-MIL) of all units connected to SC-MIL is transferred. However, the signal thereafter is not transferred. Note that SC-MIL and SC-MIL-S do not occupy any signal point. Signal channel No. Max. distance between units 10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together) Pollution degree 3 (Industrial environment) Ambient temperature –10 to +45 °C +14 to +113 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Material Enclosure: Heat-resistant ABS Weight Dimensions Net weight: 25 g approx. Net weight: 20 g approx. W16 × H39.5 × D85 mm W0.630 × H1.555 × D3.346 in W20.15 × H39.5 × D85 mm W0.793 × H1.555 × D3.346 in Accessory Connector protection seal: 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) The plug-in sensor main unit SC-MIL incorporates a cable lead-out connector in addition to the MIL connector, which allows to receive the supply voltage from the separate power supply. 3) Same as maximum permissible current consumption of all units connected to SC-MIL. When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is 2 A or less, adjust the current to the smallest value. Applicable unit of non-line connector Non-line connector Type CN-70 Designation Model No. Description Item Applicable unit Refer to the list of “Applicable unit of non-line connector” SC-T1J For NPN output devices FA COMPONENTS Supply voltage Depends on the supply voltage from SC-MIL SC-T1J-P For PNP output devices MACHINE VISION SYSTEMS UV CURING SYSTEMS Upper Communication Unit MIL Connector Plug-in SC Model No. Non-line connector ENERGY CONSUMPTION VISUALIZATION COMPONENTS 1-channel input extension units FX-501/502 For NPN output devices 1 channel FX-501P/502P For PNP output devices Ambient temperature –10 to +45 °C +14 to +113 °F (No dew condensation or icing allowed) Storage: –20 to +70 °C – 4 to +158 °F FX-301(B/G/H) FX-301-HS For NPN output devices Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH FX-301(B/G/H)P FX-301P-HS For PNP output devices FX-305 For NPN output devices FX-305P For PNP output devices FX- 411(B/G) FX- 412(B/G) For NPN output devices FX- 411(B/G)P For PNP output devices FX-311(B/G) For NPN output devices FX-311(B/G)P For PNP output devices FX-301-F For NPN output devices FX-301P-F For PNP output devices LS- 501 For NPN output devices LS- 501P For PNP output devices LS- 401/403 For NPN output devices LS- 401P For PNP output devices Digital pressure sensor DPS-401/402 For NPN output devices Compact inductive proximity sensor GA-311 For NPN output devices FX-CH For NPN input devices FX-CH-P For PNP input devices Supply current for units Signal channel No. 100 mA or less Material Enclosure: ABS Weight Net weight: 4 g approx. Digital fiber sensors (Note) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) The non-line connector now can be used with 4-pin types, such as the FX-305 and LS-401, since its production run starting in August 2004. Manually set fiber sensors Digital fiber sensors for leak detection fiber / liquid detection fiber Digital laser sensors (Note) Bank selection unit Note: O  nly the output 1 (OUT1) for the FX-502/305, LS-401/403 and DPS-401/402 can be output from the SC-MIL. There is no connection for output 2 (OUT2). Sensor-PLC Connection System SC SERIES 1014 SPECIFICATIONS FIBER SENSORS Connector extension units LASER SENSORS Connector input extension unit Type Item Model No. For NPN output devices For PNP output devices 1 channel 8 channels 1 channel 8 channels 8 channels SC-T1J SC-T8J SC-T1J-P SC-T8J-P SC-TP8J Supply voltage Current consumption (Note 3) Connector I/O mixed extension unit 12 to 24 V DC ±10 % 5 to 24 V DC ±10 % (Note 2) 20 mA or less 60 mA or less 20 mA or less 60 mA or less (when all indicators light up) (when all indicators light up) (when all indicators light up) (when all indicators light up) 7 mA or less Signal channel No. 1 input 8 inputs (Note 4) 1 input Connectable device NPN open-collector, or DC 2-wire output type sensor, or switch etc. NPN open-collector output sensor or switch etc. (Note 6) PNP open-collector, or DC 2-wire output type sensor, or switch etc. PNP open-collector Commercially available output sensor or switch I/O device including DC etc. (Note 6) 2-wire type sensor 100 mA or less 800 mA or less (At a total of 8 channels) 100 mA or less 800 mA or less 800 mA or less (At a total of 8 channels) (At a total of 8 channels) Supply current for units (Note 7) Power indicator Input indicator Ambient temperature 8 inputs / outputs (Note 5) Green LED (Lights up when the power is ON) Green LED [SC-T1J(-P): 1 No., SC-T8J(-P): 8 Nos.] (Lights up when each channel input is ON) – –10 to +45 °C +14 to +113 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Material Net weight 8 inputs (Note 4) 40 g approx. 10 g approx. 40 g approx. Dimensions W10 × H27.5 × D64.5 mm W29.15 × H39.65 × D85 mm W10 × H27.5 × D64.5 mm W29.15 × H39.65 × D85 mm W29.15 × H39.65 × D85 mm W0.394 × H1.083 × D2.539 in W1.148 × H1.561 × D3.347 in W0.394 × H1.083 × D2.539 in W1.148 × H1.561 × D3.347 in W1.148 × H1.561 × D3.347 in Accessories SL-CP1 (Snap male connector): 1 pc. Index seal: 1 pc. SL-CP1 (Snap male connector): 1 pc. MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Enclosure: Heat-resistant ABS 10 g approx. PHOTOELECTRIC SENSORS Index seal: 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) It depends on the power supply from SC-MIL. 3) The current consumption and input current of the input unit connected are not included. 4) The signal for 8 channels is occupied regardless of number of input units connected. 5) The signal for 8 channels is occupied regardless of number of I/O units connected. 6) DC 2-wire type sensor and switch etc. cannot be connected. 7) Set the maximum current passing through input / output line to 50 mA or less. STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Upper Communication Unit MIL Connector Plug-in SC
CN-70 价格&库存

很抱歉,暂时无法提供与“CN-70”相匹配的价格&库存,您可以联系我们找货

免费人工找货
CN-70
  •  国内价格 香港价格
  • 1+142.422301+18.39958

库存:41