CP
COMPACT FLAT SIZE
FOR AUTOMOTIVE
CP RELAYS
FEATURES
• Compact flat type
Flat size enables it to be built-in switch
units.
PC board terminal type:
9.5 mm .374 inch
Surface-mount terminal type:
10.5mm .413inch
• High capacity
CP Relay provides low profile
spacesaving advantages while offering
high continuous current of 25A (1 hour).
• Simple footprint pattern enables
ease of PC board layout
Arrangement of coil and contact
terminals designed to withstand large
capacity which ensures leeway and
facilitates PC board design.
RoHS compliant
• Sealed construction
Sealed construction suitable for harsh
environments
• “PC board terminal” and “Surface
mount terminal” types available
SMD automatic mounting is possible for
surface mount terminal types because
tape and reel packaging is used.
• Model available for wiper load.
TYPICAL APPLICATIONS
For automotive system
Power windows, Auto door lock, Power
sunroof, Memory seat, Wiper, Defogger,
etc.
ORDERING INFORMATION
CP
Contact arrangement
1: 1 Form C
1a: 1 Form A
1W: 1 Form C for wiper load
Mounting classification
Nil: PC board terminal/wiper load
SA: Surface-mount terminal*1
Coil voltage (DC)
12 V
Packing style*2
Nil: Tube packing
X: Tape and reel packing (picked from the NC terminal side)
Z: Tape and reel packing (picked from the coil terminal side)
TYPES
1. PC board terminal type
Contact arrangement
1 Form A
1 Form C
1 Form C for wiper load
Coil voltage
12V DC
Part No.
CP1a-12V
CP1-12V
CP1W-12V
Standard packing; Carton (tube): 40 pcs.; Case: 1,000 pcs.
2. Surface mount terminal type
Contact arrangement
Coil voltage
1 Form C
12V DC
Part No.
CP1SA-12V-X
CP1SA-12V-Z
Standard packing; Carton (tape and reel): 300 pcs.; Case: 900 pcs.
Notes: *1. Surface-mount terminal type is available only for 1 form C contact arrangement.
*2. Surface mount terminal type is only supplied in tape and reel packaging. Tube packaging is only available for PC board type.
Tape and reel packing symbol “-z” or “-x” are not marked on the relay.
ASCTB225E 201301-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
CP
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Usable voltage range
(at 85°C 185°F)
12V DC
Max. 7.2V DC
(Initial)
Min. 1.0V DC
(Initial)
53.3 mA
225Ω
640 mW
10 to 16V DC
Note: Other pick-up voltage types are also available. Please contact us for details.
2. Specifications
1) Standard CP relay
Characteristics
Contact
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Specifications
1 Form A
1 Form C
N.O.: Typ6mΩ, N.C.: Typ8mΩ (By voltage drop 6V DC 1A)
Ag alloy (Cadmium free)
20A 14V DC
N.O.: 20A 14V DC, N.C.: 10A 14V DC
N.O.: 40A for 2 minutes, 30A for 1 hour (at 20°C 68°F)
35A for 2 minutes, 25A for 1 hour (at 85°C 185°F)
640 mW
1A 14V DC
Max. carrying current (12V DC initial)*3
Rating
Nominal operating power
Min. switching capacity (resistive load)*1
Insulation resistance (Initial)
Electrical
characteristics
Mechanical
characteristics
Min. 100 MΩ (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
Between open contacts
Between contacts and coil
Operate time (at nominal voltage)
Release time (at nominal voltage)
Functional
Shock resistance
Destructive
Functional
Vibration resistance
Destructive
Breakdown voltage
(Initial)
Mechanical
Expected life
Conditions
Electrical*4
Conditions for operation, transport and storage*2
Max. operating speed
Mass
500 Vrms for 1 min. (Detection current: 10mA)
500 Vrms for 1 min. (Detection current: 10mA)
Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial)
Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial)
Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10µs)
10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G}
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 cpm)
Min. 105 (At nominal switching capacity, operating frequency: 1s ON, 9s OFF)
Min. 2×105 (N.O. side, Inrush 25A, steady 5A at 14V DC)
Min. 105 (N.O. side, 20A 14V DC at motor lock)
Min. 2×105 (N.C. side, 20A 14V DC at brake current) (Operating frequency: 0.5s ON, 9.5s OFF)
Ambient temp: –40°C to +85°C –40°F to +185°F
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
6 cpm (at rated load)
Approx. 4g .14 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Please refer to “Usage ambient
condition” in CAUTIONS FOR USE OF AUTOMOTIVE RELAYS.
Please inquire if you will be using the relay in a high temperature atmosphere (110°C 230°F).
*3. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
*4. Motor load does not apply to wiper load applications.
2) For wiper load (CP1W-12V)
Anything outside of that given below complies with standard CP relays.
Characteristics
Rating
Item
Max. carrying current (12V DC initial)*1
Expected life
Electrical
Specifications
N.O.: 25A for 1 minutes, 15A for 1 hour (at 20°C 68°F)
N.O. side: Min. 5×105 (Inrush 25A, steady 6A at 14V DC)
N.C. side: Min. 5×105 (12A 14V DC at brake current)
(Operating frequency: 1s ON, 9s OFF)
Note: *1. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB225E 201301-T
CP
REFERENCE DATA
1.-(1) Coil temperature rise (at room
temperature)
1.-(2) Coil temperature rise (85°C 185°F)
Sample: CP1-12V, 3pcs
Point measured: Inside the coil
Contact carrying current, 5A, 10A, 15A, 20A
Resistance method, ambient temperature 26°C 79°F
Sample: CP1-12V, 6pcs
Point measured: Inside the coil
Contact carrying current, 5A, 10A, 15A, 20A
Resistance method, ambient temperature 85°C 185°F
2. Max. switching capability
(Resistive load, Initial)
(N.O. side: room temperature)
60
100
120
80
10A
5A
60
40
80
15A
10A
60
5A
40
20
20
0
0
12
12
16
14
3. Ambient temperature and operating voltage
range
30
20
0
14
16
Coil applied voltage, V
0
10
20
30
40
Switching current, A
5. Distribution of operate time
Sample: CP1-12V, 100pcs
Ambient temperature: 20°C 68°F
Sample: CP1-12V, 100pcs
Ambient temperature: 20°C 68°F
Pick-up voltage
Drop-out voltage
60
25
50
100
70
90
Operating voltage range
15
50
Quantity, n
20
Quantity, n
80
40
30
70
60
50
40
10
30
20
20
5
0
−40 −20
10
Pick-up voltage
(cold start)
0
10
0
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
20 40 60 80 100 120
Ambient temperature, °C
Voltage, V
0
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
Time, ms
6. Distribution of release time
7.-(1) Electrical life test (at resistive load)
Sample: CP1-12V, 100pcs
Ambient temperature: 20°C 68°F
Sample: CP1-12V
Quantity: n = 4 (N.C. = 2, N.O. = 2)
Load: Resistive load (N.C. side: 10A 14V DC,
N.O. side: 20A 14V DC)
Operating frequency: ON 1s, OFF 9s
Ambient temperature: Room temperature
* Without diode
100
Pick-up and drop-out voltage, V
10
90
80
Quantity, n
40
4. Distribution of pick-up and drop-out voltage
30
70
60
50
40
30
20
Contact welding: 0 times
Miscontact: 0 times
8
Pick-up voltage
6
Drop-out voltage
Max.
X
Min.
2
0 0.5 1.0 1.5 2 2.5 3 3.5 4 4.5 5.0
0
Time, ms
ASCTB225E 201301-T
Max.
X
Min.
4
10
0
50
10
Coil applied voltage, V
Coil applied voltage, VDC
Switching voltage, VDC
15A
Temperature rise, °C
Temperature rise, °C
20A
20A
100
Panasonic Corporation
0
5
No. of operations, × 104
10
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
CP
7.-(2) Electrical life test for wiper load
(motor free)
Change of pick-up and drop-out voltage
Sample: CP1W-12V
Quantity: n = 5
Load: N.O. side: Inrush 25A, steady 6A 14V DC
Load: N.C. side: Brake current 12A 14V DC
Operating frequency: ON 1s, OFF 9s
Ambient temperature: Room temperature
Circuit
Change of contact resistance
50
M
8
9
7
6
Pick-up voltage
Max.
x
Min.
5
4
3
0
N.C. side
N.O. side
40
30
Max.
x
Max.
x
Min.
Min.
20
Drop-out voltage
2
10
Max.
x
Min.
1
DIMENSIONS (mm inch)
Contact resistance, mΩ
Pick-up and drop-out voltage, V
10
0
10
25
No. of operations, × 104
The CAD data of the products with a
CAD Data
0
50
0
10
25
No. of operations, × 104
50
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. PC board terminal type
External dimensions
CAD Data
14.0
.551
PC board pattern
(Bottom view)
13.0
.512
9.5
.374
1 Form A
2×2.0 +0.1
0 dia.
2×.079 +.004
dia.
0
NO
3.5
.138
COM
A*
1.0
.039
0.4
.016
5.0
.197
0.4
.016
1.5
.059
Pre-soldering
4.5
.177
0.3
.012
COIL
(R)
2×1.3+0.1
0 dia. hole
2×.051+.004
dia. hole
0
1.7
.067
6.0
.236
10.7
.421
1 Form C
5.4
.213
2.0
.079
5.0
.197
1.5
.059 6.0
.236
6.0
.236
10.7
.421
1 Form A
2×0.9 +0.1
0 dia.
dia.
2×.035 +.004
0
Max.
1.0
.039
0.4
.016
Schematic
(Bottom view)
1 Form C
3×0.9 +0.1
0 dia.
3×.035 +.004
dia.
0
3×2.0 +0.1
0 dia.
+.004
3×.079 0 dia.
NC
5.4
.213
NO
COM
2.0
.079
4.5
.177
Dimension:
Max. 1mm .039 inch:
1 to 3mm .039 to .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
COIL
(R)
+0.1
0
+.004
0
2×1.3 dia. hole
2×.051
dia. hole
6.0
.236
10.7
.421
2.0
.079
Tolerance: ±0.1 ±.004
* Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
2. Surface mount terminal type
External dimensions
CAD Data
9.1
.358
10.5
.413 0.4
.016
Recommendable mounting pad
(Top view)
Pre-soldering
0.4
0.4
.016
.016
1.55
1.55
1
.039 1.45
1.45
Sealed by
epoxy resin
5.0
.197
0.3
.012
1.6
.063
1.5
.059
0.1
1.7
.067
1.3
.051
Schematic
(Top view)
6.0
.236
NC
4.2
.165
3.8
.150
NO
2.0 .079
2.5
.098 2.5
.098
4.4
.173
COM
2.0 .079
COIL
4.8
.189
4.8
.189
5.4
.213
4.8
.189
2
.079
Dimension:
Max. 1mm .039 inch:
1 to 3mm .039 to .118 inch:
Min. 3mm .118 inch:
Panasonic Corporation
4.0
.157
Tolerance: ±0.1 ±.004
1.5
.059 6.0
.236
6.0
.236
10.7
.421
4.7
.185
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB225E 201301-T
CP
NOTES
1. Mounting and cleaning conditions
for SMT type relays
1) Recommended reflow condition is:
• Reflow-soldering temperature profile
condition (IRS method)
T3
T2
T1
t1
t2
2. Storage condition after opening a
moisture-prevention package
1) After opening a moisture-prevention
package, use the item as soon as
possible (within 3 days under an
environment of Max. 30°C 86°F, Max.
70% RH).
2) If products are not used within 4 days
after opening a moisture-prevention
package, store them in a humiditycontrolled desiccator or in a storage bag
with silica gel.
T1 = 150 to 180°C 302 to 356°F
T2 = 230°C 446°F or more
T3 = Less than 260°C 500°F
t1 = 60 to 120 sec.
t2 = Less than 40 sec.
*1
• Cautions for mounting operations
Temperature profile indicates the
temperature of the soldered part (*1) of
terminals on the surface of a circuit
board. The exterior temperature of a relay
may be extremely high depending on the
component density on the board or the
heating method of the reflow oven or
circuit board type. Sufficient verification
under actual processing conditions is
required.
2) Avoid cleaning (ultrasonic cleaning,
boiling cleaning, etc.) and coating in
order to prevent negative impacts on
relay characteristics.
For general cautions for use, please refer to the “CAUTIONS FOR USE OF AUTOMOTIVE RELAYS”
ASCTB225E 201301-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/