Cylindrical Photoelectric Sensor
CY-100 SERIES
Conforming to
EMC Directive
Listing
(2 m cable length type only)
Features
• Wide product range
Shape: Standard type
Side view type
Connector: 2 m cable length type
M12 plug-in connector type
• Diffuse reflective type sensor with
sensitivity adjuster is available.
• M18 thread size for convenient mounting
• Strong resistance IP67
• Convenient universal sensor mounting
stand is available.
ORDER GUIDE
2 m cable length type
Appearance
Sensing range
With
polarizing (Note 2.3)
filters
4m
13.12 ft
2m
6.56 ft
100 mm
0.33 ft
With
sensitivity
adjuster
Retroreflective
15 m
49.21 ft
600 mm
1.97 ft
With
polarizing (Note 2.3)
filters
15 m
49.21 ft
4m
13.12 ft
2m
6.56 ft
100 mm
3.94 in
With
sensitivity
adjuster
Retroreflective
Diffuse reflective
Side view
Thrubeam
Diffuse reflective
Standard
Thrubeam
Type
600 mm
23.62 in
Model No. (Note 1)
NPN output
PNP output
Output
operation
CY-111A
CY-111A-P
Light-ON
CY-111B
CY-111B-P
Dark-ON
CY-192A-Y
CY-192A-P-Y
Light-ON
CY-192B-Y
CY-192B-P-Y
Dark-ON
CY-191A-Y
CY-191A-P-Y
Light-ON
CY-191B-Y
CY-191B-P-Y
Dark-ON
CY-121A
CY-121A-P
Light-ON
CY-121B
CY-121B-P
Dark-ON
CY-122A
CY-122A-P
Light-ON
CY-122B
CY-122B-P
Dark-ON
CY-111VA
CY-111VA-P
Light-ON
CY-111VB
CY-111VB-P
Dark-ON
CY-192VA-Y
CY-192VA-P-Y
Light-ON
CY-192VB-Y
CY-192VB-P-Y
Dark-ON
CY-191VA-Y
CY-191VA-P-Y
Light-ON
CY-191VB-Y
CY-191VB-P-Y
Dark-ON
CY-121VA
CY-121VA-P
Light-ON
CY-121VB
CY-121VB-P
Dark-ON
CY-122VA
CY-122VA-P
Light-ON
CY-122VB
CY-122VB-P
Dark-ON
Notes: 1) The model No. with “E” shown on the label affixed to the thru-beam type sensor is the emitter, “D” shown on the label is the receiver.
(e.g.) Emitter of CY-111A: CY-111E, Receiver of CY-111A: CY-111AD
2) The reflector is sold separately.
3) The sensing range of the retroreflective type sensor is specified for the RF-420 reflector (optional).
M12 plug-in connector type
M12 plug-in connector type is also available.
When ordering this type, “-Z” for the M12 plug-in connector type to the model No.
(e.g.) M12 plug-in connector type of CY-111A-P is “CY-111A-P-Z”.
In case of the retroreflective type, M12 plug-in connector type of
CY-19□-P-Y is “CY-19□-P-Z-Y”.
1
• Standard type
• Side view type
Cylindrical Photoelectric Sensor
CY-100 SERIES
ORDER GUIDE
Mating cable (2 cables are required for the thru-beam type.)
For M12 plug-in
connector type
Type
Straight
Elbow
Model No.
Mating cable
• Straight type
Description
CN-24C-C2
Length: 2 m 6.56 ft
CN-24C-C5
Length: 5 m 16.40 ft
CN-24CL-C2 Length: 2 m 6.56 ft
CN-24CL-C5 Length: 5 m 16.40 ft
• Elbow type
Clamping ring :
ø14mm 0.55 in
Cable outer :
ø5.3mm 0.21 in
OPTIONS
Designation
Sensor mounting
bracket
Universal sensor
mounting stand
Reflector
Reflective tape
Model No.
MS-CY1-1
Material: Stainless steel
MS-CY1-2
Material: Plastic, For beam axis alignment
MS-AJ3
It can adjust the height of the sensor and
reflector RF-420.
(The thru-beam type sensor needs two
brackets.)
RF-420
50 × 50 mm 1.97 × 1.97 in
RF-410
24 × 21 mm 0.94 × 0.83 in
RF-40RL5
22 mm × 5 m 0.87 × 196.85 in,
Thickness: 0.4 mm 0.02 in
Universal sensor
mounting stand
Sensor mounting bracket
Description
• MS-CY1-1
Reflective tape
Reflector
• RF-410
• RF-420
• MS-AJ3
• MS-CY1-2
• RF-40RL5
WIRING DIAGRAMS
Wiring diagram
Emitter of thru-beam type
Receiver of thru-beam / Reflective type
NPN output type
%URZQ9
9LROHW,QSXW
±
WR9'&%
%OXH9
%URZQ9
/RDG
%ODFN2XWSXW
±
WR9'&%
%OXH9
Receiver of thru-beam / Reflective type
Connector pin position
M12 connector
PNP output type
%URZQ9
%ODFN2XWSXW
/RDG
%OXH9
±
WR9'&%
4
3
1
2
1 : +V
2 : Input (Only emitter of thru-beam type)
3:0V
4:O
utput (Only receiver of thru-beam type and reflective type)
2
Cylindrical Photoelectric Sensor
CY-100 SERIES
SPECIFICATIONS
Thru-beam
Retroreflective
Type
With polarizing filters
Model No.
Standard
Item
Diffuse reflective
Side view
Standard
Side view
Standard
Side view
With sensitivity adjuster
Standard
Side view
Standard
Side view
Light-ON
CY-111A□ CY-111VA□ CY-192A□ CY-192VA□ CY-191A□ CY-191VA□ CY-121A□ CY-121VA□ CY-122A□ CY-122VA□
Dark-ON
CY-111B□ CY-111VB□ CY-192B□ CY-192VB□ CY-191B□ CY-191VB□ CY-121B□ CY-121VB□ CY-122B□ CY-122VB□
Sensing range
15 m 49.21 ft
4 m 13.12 ft (Note 2)
Sensing object
ø18 mm ø0.71 in or
more opaque object
(Setting distance
between emitter and
receiver: 15 m 49.21ft)
ø50 mm ø1.97 in or
more opaque,
translucent or
transparent object
(Note 2, 4)
100 mm 3.94 in
(Note 3)
2 m 6.56 ft (Note 2)
ø50 mm ø1.97 in or
more opaque, translucent, transparent or
specular object
(Note 2, 4)
Opaque, translucent or transparent object
(Note 4)
–
Hysteresis
Supply voltage
600 mm 23.62 in
(Note 3)
3 to 15 % of operation distance (Note 3)
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption
Emitter: 35 mA or less
Receiver: 35 mA or less
Output
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 100 mA
• Maximum source current: 100 mA
• Applied voltage: 24 V DC or less (between output and 0 V)
• Applied voltage: 24 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less
• Residual voltage: 1.5 V or less
35 mA or less
Utilization category
DC-12 or DC-13
Short-circuit protection
Incorporated
Response time
Test input (emission halt) function
Operation indicator
Power indicator
1 ms or less
–
Incorporated
Yellow LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Green LED (lights up
when the power is ON)
(incorporated on the
emitter)
–
Environmental resistance
Pollution degree
3 (Industrial environment)
Protection
Ambient temperature
IP67 (IEC)
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –40 to +70 °C –22 to +158 °F
Ambient humidity
50 % RH (at +70 °C +158 °F)
Ambient illuminance
Incandescent light: 5,000 ℓx at the light-receiving face
EMC
EN 60947-5-2
Voltage withstandability
500 V AC for one min. between all supply terminals connected together and enclosure
Vibration resistance
10 to 55 Hz frequency, 0.5 mm 0.02 in amplitude in X, Y and Z directions for 1.5 hours each
294 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Shock resistance
Emitting element
Peak emission wavelength
Infrared LED (modulated)
890 nm 0.04 mil
875 nm 0.03 mil
Material
Cable extension
875 nm 0.03 mil
0.44 mm2 3-core cabtyre cable, 2 m 6.56 ft long
Extension up to total 10 m 32.81 ft is possible with 0.34 mm2, or more, cable (thru-beam type: both emitter and receiver).
Emitter/
Emitter/
Receiver: 65 g Receiver: 70 g
approx.
approx.
65 g
approx.
70 g
approx.
65 g
approx.
70 g
approx.
65 g
approx.
70 g
approx.
75 g
approx.
Emitter/
Emitter/
M12 plug-in connector type Receiver: 15 g Receiver: 20 g
approx.
approx.
15 g
approx.
20 g
approx.
15 g
approx.
20 g
approx.
15 g
approx.
20 g
approx.
25 g
approx.
2 m cable length type
Accessories
Infrared LED (modulated)
665 nm 0.03 mil
Enclosure: PBT, Lens: PMMA
Cable (except for M12 plug-in
connection type)
Net weight
(Note 5)
Red LED (modulated)
Nut: 4 pcs.
Nut: 2 pcs.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-420 reflector (optional).
3) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.87 × 7.87 in) as the
object.
4) Make sure to confirm detection with an actual sensor before use for detection of the transparent object and the translucent object.
5) The weight includes the weight of nuts.
3
CY-100 SERIES
Cylindrical Photoelectric Sensor
DETECTION CURVES
Thru-beam type
in
cm
in cm
0.55 1,4
0.39 1
ø 0.49 in
5.91 15
ø 12 mm
10 15
0.39 0.59
-5.91 -15
49.21 ft
15 m
A
A=Sensing range
Diffuse reflective type with
adjustable sensitivity
Diffuse reflective
m
1.97 5
-0.39 -1
-0.55 -1,4
1,4
1
in
0,59
15
cm
2
3.94 in
A 10 cm
in cm
0.55 1.4
0.39 1
-0.39 -1
-0.55 -1.4
in
2.62
80
cm
23.62 in
A 60 cm
1
Object 10 × 10 cm; 1 White 90%; 2 Grey 18%
Retroreflective type with
polarizing filters
Retroreflective type
ø of beam
in cm
3.94 10
1.57
4
-1.57 -4
-3.94 -10
2
0.79
4
1.57
13.12 ft
A 4m
With reflector RF-420
m
E/R
in cm
2.36 6
1.57 4
0.79 2
-0.79 -2
-1.57 -4
-2.36 -6
0,2
0.79
A
2
1.18
3
0.39
m
6.56 ft
2m
With reflector RF-420
10 cm
-1
-1,4
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device for
personnel protection.
• In case of using sensing devices for personnel
protection, use products which meet laws and
standards, such as OSHA, ANSI or IEC etc.,
for personnel protection applicable in each
region or country.
Mounting
• The tightening torque should be 3 N·m or less.
• Use a cable with connector CN-24C(L)-C□ (optional) for M12
connector type.
Tightening torque for connector part is 2 N·m or less.
%RG\
1XW
0RXQWLQJSODWH
&DEOHZLWKFRQQHFWRU
1XW
Mounting drawing with sensor or reflector RF-420
Wiring
• Make sure that the power supply is off while wiring.
• Verify that the supply voltage variation is within the rating.
• If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
• Ensure that an isolation transformer is utilized for the DC power
supply. If an autotransformer is utilized, the main body or power
supply may be damaged.
• If the used power supply generates a surge, connect a surge
absorber to the power supply to absorb the surge.
• Do not use during the initial transient time (0.5 sec) after the power
supply is switched on.
• In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the
frame ground (F.G.) terminal of the equipment to an actual
ground.
• Do not run the wires together with high-voltage lines or power lines
or put them in the same raceway. This can cause malfunction due
to induction.
• Damage or burnout may result in case of short circuit of load or
miswiring.
• Make a cable length as short as possible to lessen noise pickup.
Others
• Our products have been developed / produced for industrial use
only.
• Take care that the sensor is not directly exposed to fluorescent
lamp from a rapid-starter lamp or a high frequency lighting device,
as it may affect the sensing performance.
• Avoid using a product where there is excessive vapor, dust or
corrosive gas, or in a place where it could be exposed directly to
water or chemicals.
• Take care that the sensor does not come in direct contact with
water, oil, grease or organic solvents, such as, thinner, etc.
• Do not use in an environment containing infammable or explosive
gases.
• Never disassemble or modify the product.
4
Cylindrical Photoelectric Sensor
CY-100 SERIES
DIMENSIONS (Unit: mm in)
CY-1□
Sensor
M18
2 m cable length type (mm in)
b
a
M12 plug-in connector type (mm in)
a
b
a
b
Standard type CY-111□/121□/192□
46 1.81
28 1.10
60 2.36
28 1.10
Standard type CY-191□
48 1.89
28 1.10
62 2.44
28 1.10
Side view type CY-111V□/121V□/191V□/192V□
62 2.44
28 1.10
76 2.99
28 1.10
Standard type CY-122□
62 2.44
44 1.73
76 2.99
44 1.73
Side view type CY-122V□
78 3.07
44 1.73
92 3.62
44 1.73
CN-24C-C2 CN-24C-C5
¡
¡
CN-24CL-C2 CN-24CL-C5
Mating cable
Mating cable
27
1.06
ø14
ø0.55
0×
BK
3
BN
/
¡
¡
MS-CY1-2
Sensing mounting bracket
45
1.77
25
0.98
=
24
0.94
8
0.32
= =
6.5
0.26
27
1.06
=
8
0.32
=
10
0.39
55 2.17
5
0.20
1
0.04
6.5
0.26
15
0.59
20
0.79
19.5
0.77
6.5
0.26
MS-AJ3
Universal sensor mounting stand
53
2.09
ø6.5
ø0.26
36
1.42
12
0.47
19
0.75
M12
19
0.75
132
5.20
19
0.75
40 1.57
126 4.96
55
2.17
40
1.57
1.9
0.07
22.9
0.90
67
2.64
40
1.57
33
1.30
M4
76.5
3.01
5
5.7
0.22
3. Support for M12 rod
50
1.97
36
1.42
2. M12 rod
23
0.91
1. Ball-joint mounted fixing bracket CY-100 series or RF-420
ø18.5
ø0.73
BN
ø18.2
ø0.72
20
0.79
=
16.5
0.65
28
1.10
1
2
Sensing mounting bracket
10
0.39
ø18.2
ø0.72
35
1.38
50
1.97
4
WH
ø10
ø0.39
L = 2 or 5 m
6.56 or 16.40 ft
2.5
0.10
BK
3
1
2
MS-CY1-1
BU
4
WH
L = 2 or 5 m
6.56 or 16.40 ft
Connector pin position
38
1.50
BU
M12 × 1
L
Connector pin position
DIMENSIONS (Unit: mm in)
3.5
8 0.14
0.32
51.5
2.03
8
0.32
ø4.5
ø0.18
Reflector
9
0.35
ø7.5
ø0.30
4
0.16
7.5
0.30
24 0.94
=
=
29
1.14
33
1.30
60 2.36
2 - ø4.5
ø0.18
47 1.85
69 2.72
51 2.01
35 1.38
2 - ø5.5
ø0.22
RF-410
21
0.83
Reflector
4 - R5
R0.20
45
1.77