DE (ADE)
VDE
COMPACT
HIGH-INSULATION
POLARIZED POWER RELAY
25.0
.984
DE RELAYS (ADE)
FEATURES
12.5
.492
12.5
.492
mm inch
• Conforms to European safety
standards (VDE0700 and VDE0631)
Insulating distance between coil and
contacts:
Clearance Min. 8mm .315 inch
Creepage distance Min. 8mm .315 inch
• Extensive product line-up
• Surge voltage between contact and
coil 12 kV
• Low operating power
Nominal operating power at 200 mW
(Single side stable, 2 coil latching)
• Compact body saves space
Size: 12.5(W) × 25.0(L) × 12.5(H) mm
.492(W) × .984(L) × .492(H) inch
• UL/CSA, VDE approved
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
Max. operating speed
20 cpm (at rated load)
Min. 1,000 MΩ
(at 500 V DC)
Initial insulation resistance*1
Between open contacts
Initial contact resistance, max. (By voltage
drop 6V DC 1A)
Rating
(resistive
load)
2 Form A
AgSnO2 type
Contact material
Nominal
switching
capacity
1 Form A
1 Form B
Initial
breakdown
voltage*2
30mΩ
10A 250V AC, 8A 250V AC, 8A 250V AC,
10A 30V DC 8A 30V DC
8A 30V DC
Between contact sets
Between contact and coil
Surge voltage between contact and coil*3
1,000 Vrms
4,000 Vrms (2 Form A,
1 Form A 1 Form B)
5,000 Vrms
Min. 12,000 V (initial)
Max.
switching
power
2,500 VA*,
300W
2,000 VA*,
240W
2,000 VA*,
240W
Operate time [Set time]*4
Max. 10ms (typ. 5ms)
[Max. 10ms (typ. 4ms)]
(at 20°C 68°F)
Max.
switching
voltage
440V AC,
230V DC
440V AC,
230V DC
440V AC,
230V DC
Release time (without diode) [Reset time]*4
Max. 5ms (typ. 2ms)
[Max. 10ms (typ. 4ms)]
(at 20°C 68°F)
Max.
switching
current
10A (16A)*
8A (16A)*
Min. switching capacity#1
100 mA, 5 V DC
Mechanical
(at 300cpm)
107
Electrical
Expected
(at 20 cpm)
life (min.
(resistive load)
operations)
Electrical
(16A / 230 V
AC resistive)*
Max. 50°C
Temperature rise (at 70°C)*5
8A (16A)*
Shock resistance
Functional*6
Min. 196 m/s2{20 G}
Destructive*7
Min. 980 m/s2{100 G}
Functional*8
10 to 55 Hz at double
amplitude of 2 mm
Destructive
10 to 55 Hz at double
amplitude of 3 mm
Vibration resistance
105(AC)
5 × 104(DC)
10
5
25000
20000
Conditions for operation,
transport and storage*9
(Not freezing and condensing at low temperature)
Unit weight
Ambient temp.
–40°C to 70°C
–40°F to 158°F
Humidity
5 to 85% R.H.
Approx. 7 g .25 oz
Coil (at 20°C, 68°F)
Nominal operating power
Single side stable
200 mW
1 coil latching
100 mW
2 coil latching
200 mW
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
ds_61A01_0000_en_de: 151209D
Remarks
* 16A possible for one contact set only with max. 4000 VA switching power.
*1 Measurement at same location as “Initial breakdown voltage” section.
*2 Detection current: 10mA
*3 Wave is standard shock voltage of ±1.2 × 50μs according to JEC-212-1981
*4 Nominal operating voltage applied to the coil, excluding contact bounce time.
*5 By resistive method
*6 Half-wave pulse of sine wave: 11ms, detection time: 10ms.
*7 Half-wave pulse of sine wave: 6ms
*8 Detection time: 10ms
*9 Refer to “6. Usage, Storage and Transport Conditions” in AMBIENT
ENVIRONMENT section in Relay Technical Information.
1
DE (ADE)
TYPICAL APPLICATIONS
ORDERING INFORMATION
Ex.
• Temperature controller
• Automatic meter reading
• OA equipment
• FA equipment
Product name
DE
1a
DE
L
Contact arrangement
1a: 1 Form A
1a1b: 1 Form A 1 Form B
2a: 2 Form A
3
Operating function
Nil: Single side stable
L: 1 coil latching
L2: 2 coil latching
Notes: 1) Standard packing; Carton (tube package)
20 pcs. Case 500 pcs.
V
Coil voltage, V DC
1.5, 3, 4.5, 5,
6, 9, 12, 24, 48**
**just for single side stable
2) UL/CSA, VDE approved type is standard.
TYPES AND COIL DATA (at 20°C 68°F)
• Single side stable type
1 Form A, 1 Form A 1 Form B, 2 Form A
Nominal
voltage,
V DC
Pick-up
voltage,
V DC (max.)
(initial)
Drop-out
voltage,
V DC (min.)
(initial)
Coil resistance,
Ω (±10%)
Nominal operating
current,
mA (±10%)
Nominal operating
power,
mW
Max.
allowable
voltage,
V DC
1.5
1.05
0.15
11.3
132.7
200
1.95
3
2.1
0.3
45
66.6
200
3.9
4.5
3.15
0.45
101
44.5
200
5.85
DE-5V
5
3.5
0.5
125
40
200
6.5
DE-6V
6
4.2
0.6
180
33.3
200
7.8
Part No.
DE-1.5V
DE-3V
DE-4.5V
DE-9V
9
6.3
0.9
405
22.2
200
11.7
DE-12V
12
8.4
1.2
720
16.6
200
15.6
DE-24V
24
16.8
2.4
2,880
8.3
200
31.2
DE-48V
48
33.6
4.8
11,520
4.2
200
62.4
Nominal
voltage,
V DC
Set voltage,
V DC (max.)
(initial)
Reset
voltage,
V DC (min.)
(initial)
Coil resistance,
Ω (±10%)
Nominal operating
current,
mA (±10%)
Nominal operating
power,
mW
Max.
allowable
voltage,
V DC
1.5
1.05
1.05
22.5
66.6
100
1.95
3
2.1
2.1
90
33.3
100
3.9
4.5
3.15
3.15
202
22.3
100
5.85
DE-L-5V
5
3.5
3.5
250
20
100
6.5
DE-L-6V
6
4.2
4.2
360
16.7
100
7.8
• 1 coil latching type
1 Form A
Part No.
DE-L-1.5V
DE-L-3V
DE-L-4.5V
DE-L-9V
9
6.3
6.3
812
11.1
100
11.7
DE-L-12V
12
8.4
8.4
1,440
8.3
100
15.6
DE-L-24V
24
16.8
16.8
5,760
4.2
100
31.2
Nominal
voltage,
V DC
Set voltage,
V DC (max.)
(initial)
Reset
voltage,
V DC (min.)
(initial)
Coil resistance,
Ω (±10%)
Nominal operating
current,
mA (±10%)
Nominal operating
power,
mW
Set coil
Reset coil
Set coil
Reset coil
Set coil
Reset coil
Max.
allowable
voltage,
V DC
1.5
1.05
1.05
11.3
11.3
66.6
66.6
200
200
1.95
3
2.1
2.1
45
45
66.6
66.6
200
200
3.9
4.5
3.15
3.15
101
101
44.5
44.5
200
200
5.85
DE-L2-5V
5
3.5
3.5
125
125
40
40
200
200
6.5
DE-L2-6V
6
4.2
4.2
180
180
33.3
33.3
200
200
7.8
• 2 coil latching type
1 Form A
Part No.
DE-L2-1.5V
DE-L2-3V
DE-L2-4.5V
DE-L2-9V
9
6.3
6.3
405
405
22.2
22.2
200
200
11.7
DE-L2-12V
12
8.4
8.4
720
720
16.6
16.6
200
200
15.6
DE-L2-24V
24
16.8
16.8
2,880
2,880
8.3
8.3
200
200
31.2
Note: Insert contact arrangement, e.g.1a, 1a1b, 2a, in for contact form required.
2
ds_61A01_0000_en_de: 151209D
DE (ADE)
DIMENSIONS
mm inch
PC board pattern (Bottom view)
Single side stable
2 coil latching type
1 coil latching type
Single side stable
1 coil latching type
25.0
.984
12.5
.492
15.24
.600
12.0
.472
7.62
.300
12.70
.500
8-1.2 dia
8-.047 dia
7.62
.300
7.62
.300
3.5
.138
0.8
.032
15.24
.600
7.62
.300
0.8
.032
1.0
.039
0.4
.016
7.62
.300
2.44
.096
Tolerance : ±0.1 ±.004
Schematic (Bottom view)
Single side stable
(1 Form A)
2 coil latching type
25.0
.984
1
3
4
8
6
5
(1 Form A 1 Form B)
(2 Form A)
1
3
4
1
3
4
8
6
5
8
6
5
12.5
.492
12.0
.472
2.54
.100
2.54
.100
7.62
.300
0.5
.020
0.5 dia
.020 dia
0.5
.020
0.5 dia
.020 dia
6-1.2 dia
6-.047 dia
(5,6: dummy terminal)
(Deenergized condition)
(1 Form A)
(1 Form A 1 Form B)
1coil latching type
3.5
.138
0.5 dia
.020 dia
12.70
.500
0.8
.032
7.62
.300
0.8
.032
1.0
.039
0.4
.016
7.62
.300
2.44
.096
1
3
4
1
8
6
5
8
(2 Form A)
3
4
1
3
4
6
5
8
6
5
(5,6: dummy terminal)
(Reset condition)
(1 Form A)
(1 Form A 1 Form B)
2coil latching type
Tolerance: ±0.3 ±.012
1
2
3
4
1
8
7
6
5
8
(5,6: dummy terminal)
(2 Form A)
2
3
4
1
2
3
4
7
6
5
8
7
6
5
(Reset condition)
REFERENCE DATA
2. Life curve
Current, A
Contact load, A
1. Max. switching power
Contact voltage
No. of operations
3.-(1) Coil temperature rise (1 Form A)
3.-(2) Coil temperature rise (1 Form A 1 Form B)
3.-(3) Coil temperature rise (2 Form A)
Tested sample: ADE109
Quantity: n=6
Ambient temperature: 25°C to 70°C 77°F to 158°F
Tested sample: ADE309
Quantity: n=6
Ambient temperature: 25°C to 70°C 77°F to 158°F
Tested sample: ADE209
Quantity: n=6
Ambient temperature: 25°C to 70°C 77°F to 158°F
50
10A
0A
10A
0A
30
20
8A
0A
8A
30
0A
20
10
10
0
40
70
80
90
100
110 120
Coil applied voltage, %V
ds_61A01_0000_en_de: 151209D
130
0
Temperature rise, °C
40
50
25°C 77°F
70°C 158°F
25°C 77°F
70°C 158°F
Temperature rise, °C
Temperature rise, °C
50
25°C 77°F
70°C 158°F
8A
40
8A
0A
0A
30
20
10
70
80
90
100
110 120 130
Coil applied voltage, %V
0
70
80
90
100
110 120 130
Coil applied voltage, %V
3
DE (ADE)
4-1. Operate/release time (1 Form A)
4-2. Operate/release time (1 Form A 1 Form B)
4-3. Operate/release time (2 Form A)
Tested sample: DE1a-5V
Quantity: n=5
Tested sample: DE1a1b-5V, Quantity: n=5
Tested sample: DE2a-5V, Quantity: n=5
7
40
10A
0A
10A
0A
30
20
10
6
Max.
x
Min.
5
4
3
70
80
90
100
110 120
Coil applied voltage, %V
130
Max.
x
Min.
Max.
x
Min.
Operate time
2
7
Operate time
6
Max.
x Max.
Min.
x
Min.
5
4
3
Release time
(With diode)
2
Release time
1
0
8
Release time
(With diode)
Operate/release time, ms
25°C 77°F
70°C 158°F
Operate/release time, ms
Temperature rise, °C
50
0
70
80
90
100
Max.
x
Min.
1
110
120
0
130
Release time
70
80
Coil applied voltage, %V
90
100 110
120 130
Coil applied voltage, %V
Tested sample: DE1a-5V, Ambient temperature:
–40°C to 80°C –40°F to 176°F, Quantity: n=6
Tested sample: DE1a1b-5V, Ambient temperature:
–40°C to 80°C –40°F to 176°F, Quantity: n=6
Tested sample: DE2a-5V, Ambient temperature:
–40°C to 80°C –40°F to 176°F, Quantity: n=6
-40
-40
-20
-4
0
32
-10
-20
30
20
Drop-out
voltage
Pick-up
voltage
10
0
20 40
68 104
60
140
80
176
Ambient
temperature,°C °F
-30
-40
-40
-20
-4
0
32
Rate of change, V%
5-3. Ambient temperature characteristics
(2 Form A)
Rate of change, V%
5-2. Ambient temperature characteristics
(1 Form A 1 Form B)
Rate of change, V%
5-1. Ambient temperature characteristics
(1 Form A)
30
Drop-out
20 voltage
10
0
Pick-up
voltage
20 40
60
80
68 104 140 176
-10
Ambient
temperature,°C °F
-20
-30
-40
-40
-20
-4
0
32
-10
-20
30
Drop-out
20 voltage
Pick-up
voltage
10
0
20 40
60
80
68 104 140 176
Ambient
temperature,°C °F
-30
Contact resistance, Ω
6. Change of contact resistance
No. of operations
For Cautions for Use, see Relay Technical Information.
4
ds_61A01_0000_en_de: 151209D