0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DP-001-J

DP-001-J

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    PANASONIC ELECTRIC WORKS - DP-001-J - DIGITAL PRESSURE SENSOR, 100KPA, M5

  • 数据手册
  • 价格&库存
DP-001-J 数据手册
For gas Digital Pressure Sensor DP-0 SERIES Conforming to EMC Directive Simpler and Easier to Use 2015.06 panasonic.net/id/pidsx/global DP-0 Simple & Easy Operation Two levels of setting mode for easy operation of essential functions The “RUN mode” is for threshold value setting, zero point adjustment and key lock setting / release setting, and the “detailed setting mode” allows for basic settings for sensor operation. The two-level setting mode configuration enables easy and immediate use of the product. Detailed setting mode Pressure unit setting mode RUN mode Operation setting mode NO / NC setting mode • Threshold value setting • Zero point adjustment • Key lock setting / release Response time setting mode Display color setting mode Settings initializing mode Main menu for detailed setting mode Operation setting mode* NO / NC setting mode Response time setting mode Display color setting mode Select from EASY mode, hysteresis mode or window comparator mode. Set the comparative output operation to NO or NC. Select the response time from 2.5 ms, 25 ms or 250 ms. Select the comparative output ON / OFF display color and the normal display color from red or white. * For details of operation setting mode, see page 4. Functional Design Crisp clicking feel Black body for enhanced visibility of LCD display The unit body is completely black to make the LCD display easier to see. Firm and crisp clicking feel The buttons offer firm and crisp clicking feel for smooth and reliable setting operations. 2 DP-0 Simp le DP-0 Redesigned for improvement of pressure sensor usability from ground up Eas y Setti ng High-Quality LCD Display Pressure / setting display Simple and highly visible display Comparative output ON / OFF mark Key lock mark OVER mark Pressure unit display Low pressure type: kPa, kgf/cm2, bar, psi, mmHg High pressure type: MPa, kgf/cm2, bar, psi RUN mode Detailed setting mode The LCD offers a wide viewing angle so the display is easy to see even from an oblique angle. The alphanumeric display (12-segment display), key lock mark and OVER mark further enhance the recognition of display. Selection of display color from red or white The display color can be selected from red or white in accordance with the output operation. Since the detailed setting mode display is pink (unchangeable), the pressure sensor status can be easily recognized by color. Display color setting Mode Red for ON, white for OFF White for ON, red for OFF RUN mode Comparative output ON Comparative output OFF Red White White Red Detailed setting mode Red White Red in normal status White in normal status Pink Compact & Light Weight Design Extra-short depth and light weight The unit body measures only 24.9 mm 0.980 in in depth to allow installation in a narrow space. The main unit weighs only about 25 g. The lightweight unit means minimal load when mounted on a moving part such as a robot arm. Comparison with Depth : Approx. previous model dimension Main unit (DP-100 series standard : Approx. pressure port type) weight 41% shorter! 38% lighter! Previous model DP-0 series Approx. 25 g 24.9 mm 0.980 in (DP-100 series standard pressure port type) < Actual size > Approx. 40 g 42.5 mm 1.673 in 3 DP-0 High pressure type Low pressure type Low Pressure Type and High Pressure Type Available Two types to choose from according to applications Applications The low pressure type can be used with positive or negative pressure, while the high pressure type is suitable for positive pressure of up to 1 MPa. Suction confirmation for electronic parts Reference pressure check Ideal for applications such as suction. No misoperations due to vacuum breakdown occur. −100 kPa Low pressure type 0 kPa DP-001□ High pressure type Ideal for applications such as checking reference 100 kPa pressure. Can also be used for simple suction. 1 MPa DP-002□ Three Output Modes Equipped with three output modes for use in a wide range of applications H (Hysteresis) 0 Comparative ON output OFF H: 4 digits (fixed) (10 digits or more when using psi unit) 4 (3) Window comparator mode This mode is used for setting comparative output ON and OFF at pressures within the setting range. P-2 P-1 0 Comparative ON output OFF H (Hysteresis) H: 2 digits or more (5 digits or more when using psi unit) Pressure Pressure P-1 (2) Hysteresis mode This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON / OFF control. Pressure (1) EASY mode This mode is used for comparative output ON / OFF control. P-2 H (Hysteresis) H (Hysteresis) P-1 0 Comparative ON output OFF H: 4 digits or more (10 digits or more when using psi unit) DP-0 Designed for Easy Installation Tight installation is possible Panel mounting bracket An exclusive mounting bracket that is suitable for 1 to 3 mm 0.039 to 0.118 in panel thickness is available. Panel mounting bracket MS-DP1-8 Neat and space saving Front protection cover MS-DP1-3 Tight insta llation is Exclusive mounting bracket possible A single mounting hole Supports tight installation MS-DP1-1 M3 (length 6 mm 0.236 in) screws with washers (Accessory for MS-DP1-1) Space savings can also be achieved even when an L-shaped mounting bracket is used. Tight installation is possible Ceiling mounting Floor mounting MS-DP1-5 M3 (length 6 mm 0.236 in) screws with washers (Accessory for MS-DP1-5) Positioning bosses for easier mounting bracket installation Connection cable Cable can be connected with one-touch Connector attached cable (2 m 6.562 ft), as an accessory, can be connected easily with one-touch connection. Connection cable * * Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available. Rear mounting Types without connector attached cable are also available DP-00□- J Commercially-available connectors can be used for cable connections. Cables in required length can be used, so this contributes to reduction in waste of unwanted cables. Environmentally friendly Commercially-available parts can be used! Refer to p.6 for recommended commercially-available connectors. 5 DP-0 ORDER GUIDE Model No. DP-00 1 - P - J Rated pressure range Cable 1 : −100.0 to +100.0 kPa (Low pressure type) 2 : 0.000 to +1.000 MPa (High pressure type) None : Connector attached cable 2 m 6.562 ft J : Type without connector attached cable Comparative output None : NPN output type P : PNP output type Type Appearance Rated pressure range Low pressure type High pressure type −100.0 to +100.0 kPa *CN-14A-C2 (Connector attached cable 2 m 6.562 ft ) is attached. 0.000 to +1.000 MPa Type without connector attached cable Model No. Pressure port DP-001 DP-001-P DP-002 DP-002-P Comparative output NPN open-collector transistor M5 female thread PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor Accessory Type without connector attached cable CN-14A-C2 is available. When ordering this type, suffix “-J” to the end of Model No. (e.g.) Type without connector attached cable of DP-001-P is “DP-001-P-J” •• CN-14A-C2 (Connector attached cable 2 m 6.562 ft) OPTIONS Designation Model No. CN-14A-C1 Connector attached cable Connector attached cable (Flexible cable) Description Length: 1 m 3.281 ft CN-14A-C2 (Note) Length: 2 m 6.562 ft CN-14A-C3 Length: 3 m 9.843 ft CN-14A-C5 Length: 5 m 16.404 ft CN-14A-R-C1 Length: 1 m 3.281 ft CN-14A-R-C2 Length: 2 m 6.562 ft CN-14A-R-C3 Length: 3 m 9.843 ft 0.2 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in 0.2 mm2 4-core flexible cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in Length: 5 m 16.404 ft CN-14A Set of 10 housings and 40 contacts MS-DP1-1 Allows sensors to be installed on the flooring or ceiling. Multiple sensors can also be mounted closely. MS-DP1-5 Allows sensors to be installed on the wall. Multiple sensors can also be mounted closely. Panel mounting bracket MS-DP1-8 Allows installation to panels with thickness of 1 to 3 mm 0.039 to 0.118 in. Multiple sensors can also be mounted closely. Front protection cover MS-DP1-3 Protects the adjustment surfaces of sensors. (Can be attached when using the panel mounting bracket) Sensor mounting bracket Note: The connector attached cable CN-14A-C2 is supplied with the DP-0 series. 6 Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended crimping tool CN-14A-R-C5 Connector Recommended connector Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. DP-0 SPECIFICATIONS Model No. Type Item Low pressure High pressure NPN output DP-001 DP-002 PNP output DP-001-P DP-002-P Type of pressure Rated pressure range Set pressure range Pressure withstandability Gauge pressure −100.0 to +100.0 kPa 0.000 to +1.000 MPa −101.0 to +101.0 kPa −1.030 to +1.030 kgf/cm2 −1.010 to + 1.010 bar −14.65 to +14.65 psi −756 to +756 mmHg −0.010 to +1.010 MPa −0.1 to +10.30 kgf/cm2 −0.1 to + 10.10 bar −0.1 to +146.5 psi 500 kPa 1.5 MPa Applicable fluid Selectable unit Supply voltage Air, non-corrosive gas Low pressure type: kPa, kgf/cm2, bar, psi, mmHg 12 to 24 V DC ±10 % Ripple P-P 10 % or less Power consumption Comparative output Output operation 30 mA or less NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between comparative output and 0 V) • Residual voltage: 2 V or less (at 50 mA sink current) Response time Minimum 2 digits (variable) ±0.2 % F.S. (within ±4 digits) ±0.4 % F.S. (within ±4 digits) 2.5 ms, 25 ms, 250 ms, selectable by key operation Short-circuit protection Display Incorporated 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) Displayable pressure range Environmental resistance PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between comparative output and +V) • Residual voltage: 2 V or less (at 50 mA source current) Selectable either NO or NC by key operation Hysteresis Repeatability High pressure type: MPa, kgf/cm2, bar, psi −101.0 to +101.0 kPa −1.030 to +1.030 kgf/cm2 −1.010 to + 1.010 bar −14.65 to +14.65 psi −756 to +756 mmHg −0.010 to +1.010 MPa −0.1 to +10.30 kgf/cm2 −0.1 to + 10.10 bar −0.1 to +146.5 psi Protection Ambient temperature Ambient humidity Voltage withstandability IP40 (IEC) 0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: -10 to +60 °C +14 to +140 °F 35 to 85 % RH, Storage: 35 to 85 % RH 500 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each Pollution degree 2 Overvoltage category I Usable altitude Temperature characteristics (+20°C standard) Grounding method Pressure port Material Weight Accessory 2,000 m 6,562 ft or less +10 to +40°C +50 to +104°F: Within ±1 % F.S. 0 to +50°C 32 to +122°F: Within ±2.5 % F.S. +10 to +40°C +50 to +104°F: Within ±2 % F.S. 0 to +50°C 32 to +122°F: Within ±5 % F.S. Floating M5 female thread Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated), Mounting threaded part: Brass, O-ring: Nitrile rubber (NBR), Key section: Polycarbonate 25 g approx. CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1 pc. Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 7 DP-0 I/O CIRCUIT AND WIRING DIAGRAMS NPN output type I/O circuit diagram Terminal arrangement diagram Terminal No. Color code of connector attached cable (Brown) +V 1 Sensor circuit D1 3 D2 Tr 2 (White) Not connected (Note) Load (Black) Comparative output + − 50 mA MAX. ZD 2 3 4 Terminal No. (Blue) 0 V 4 Internal circuit 1 12 to 24 V DC ±10 % Designation Users’ circuit +V Note: Open or, connect to 0 V. Comparative output Symbols…D1, D2: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: NPN output transistor Not connected (Note) 0V Note: Open or, connect to 0 V. PNP output type Terminal arrangement diagram I/O circuit diagram Terminal No. Color code of connector attached cable Sensor circuit D1 Tr (Brown) +V 1 ZD 50 mA MAX. D2 2 3 4 (Black) Comparative output (White) Not connected (Note) Load + − (Blue) 0 V Internal circuit 1 12 to 24 V DC ±10 % 2 3 Terminal No. Users’ circuit 8 Designation +V Note: Open or, connect to 0 V. Symbols…D1, D2: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: PNP output transistor 4 Comparative output Not connected (Note) 0V Note: Open or, connect to 0 V. DP-0 PRECAUTIONS FOR PROPER USE • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • This product is used for noncorrosive gas. The product shall not be used for liquid or corrosive gas. Never use fluids having inflammability, toxicity, etc., that affect the human body, either. Part description Digital display unit Connecting connector OFF mark OVER mark Pressure port (M5 female thread) Mode selection key How to connect •• Insert the cable with connector CN‑14A(‑R)‑C□ into this product’s connection connector section as shown in the right figure. Release lever How to disconnect •• Pressing the release lever of the cable with connector, pull out the connector. Cable with connector CN-14A(-R)-C□ Note: Do not pull by holding the cable without pressing the release lever, as this can cause cable break or connector break. Factory setting ON mark Key lock mark Connection Setting value UP key Setting value DOWN key Type Low pressure type Operation setting NO / NC setting NC NO Threshold value −50.0 0.500 Pressure unit kPa MPa Display color Red when ON, White when OFF Response speed Piping •• When using this product, connect a joint available in the market to the pressure port. At the time, the tightening torque should be 1.0 N·m or less. •• Use sensor mounting bracket MS‑DP1‑1 prepared independently. When mounting this product with sensor mounting bracket, etc., the tightening torque should be 0.5 N·m or less. M3 (length 6 mm 0.236 in) screws with washers (Accessory with MS-DP1-1) Sensor mounting bracket MS-DP1-1 (Optional) •• Panel fittings MS‑DP1‑8 (optional) and front cover MS‑DP1‑3 (optional) are available. •• For the method for mounting panel fittings, refer to the instruction manual that came with the MS‑DP1‑8. Wiring •• Make sure that the power supply is OFF while performing the wiring operation. •• Verify that the supply voltage variation is within the rating. •• If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. •• In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. •• When extending the cable, use a cable whose conductor crosssectional area is 0.3 mm2 or more. The cable can be extended to up to 10 m 32.808 ft in total length. •• Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. •• Do not apply stress directly to the connection cable leader or to the connector. 2.5 ms Error indication Error indication Mounting High pressure type EASY mode Description Remedy The load is short-circuited causing an overcurrent to flow. Turn OFF the power and check the load. Pressure is applied during zero point adjustment. Applied pressure at the pressure port should be brought to atmospheric pressure and zero-point adjustment should be done again. The applied pressure exceeds the upper limit of the displayed pressure range. The applied pressure exceeds the lower limit (back pressure) of the displayed pressure range. Applied pressure range should be brought within the rated pressure range. When other error massage is displayed, contact us. Others •• This product has been developed / produced for industrial use only. •• The product shall be used only within the rated pressure range. •• Do not apply pressure exceeding the pressure resistance. Otherwise, destruction of diaphragm occurs, preventing the product to perform normal operation. •• Do not use during the initial transient time (0.5 sec.) after the power supply is switched ON. •• The specification may not be satisfied in a strong magnetic field. •• This product is suitable for indoor use only. •• Take care that strong impact such as fall is not given to this product. Otherwise, it may be destroyed. •• Avoid dust, dirt, and steam. •• Take care that the product does not come into contact with organic solvents such as thinner. •• Take care that the product does not come into contact with oil or grease. •• Take care that the product does not come into contact with strong acid or alkaline. •• Do not insert wire into the pressure port. Otherwise, destruction of diaphragm occurs, preventing the product to perform normal operation. 9 DP-0 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website. DP-00□ Sensor 24.9 0.980 30 1.181 20 0.787 Connector 20 0.787 4.9 0.193 Display 30 1.181 ø8.35 ø0.329 Setting value DOWN key Mode selection key 2-ø2.5 0.098, 5 0.197 deep 20 0.787 M5 female thread, 4 0.157 deep 1.3 0.051 2-M3 female thread, 4 0.157 deep Setting value UP key MS-DP1-1 Sensor mounting bracket (Optional) ø2.3 ø0.091 22 0.866 9.5 14.5 0.571 0.374 2-R2.1 R0.083 1 0.039 4.2 0.165 21 0.827 30 1.181 20 0.787 13 0.512 20 R13 0.787 R0.512 t2 t 0.079 Assembly dimensions 14.5 9.5 0.571 0.374 2-R2.1 R0.083 4.2 0.165 2-ø3.5 ø0.138 24.9 0.98 4.9 0.193 5.3 (0.209 ) 45 (1.772 ) ø8.35 ø0.329 30 1.181 5.5 44 0.217 1.732 20 0.787 20 0.787 45 1.772 1.3 0.051 15 0.591 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Two M3 (length 6 mm 0.236 in) screws with washers are attached. 30 t 2 1.181 t 0.079 30 1.181 MS-DP1-5 Sensor mounting bracket (Optional) Assembly dimensions 22.75 0.896 4.5 0.177 R6.75 R0.266 29.5 1.161 20 0.787 ø4.5 ø0.177 28 1.102 16 0.630 8.5 0.335 24.9 0.980 4.9 0.193 44.5 30 1.752 1.181 20 0.787 13.5 0.531 20 0.787 2-ø3.5 ø0.138 t 1.5 t 0.059 Material: Stainless steel (SUS304) Two M3 (length 6 mm 0.236 in) screws with washers are attached. 10 49.5 (1.949 ) ø4.5 ø0.177 ø8.35 ø0.329 49.5 1.949 20 0.787 28.5 1.122 20 0.787 29.5 1.161 30 1.181 4.5 0.177 1.3 0.051 26.5 1.043 48 1.890 t 1.5 t 0.059 DP-0 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website. MS-DP1-8  MS-DP1-3 Panel mounting bracket (Optional), Front protection cover (Optional) Mounting drawing with DP-00□ Panel cut-out dimensions When 1 unit is installed 0 31−0.4 0 1.220 −0.016 0 0 31−0.4 1.220 −0.016 (39.3 1.547) 34.5 1.358 Front protection cover 11 0.433 7.2 12.8 0.283 0.504 4.9 0.193 ø8.35 ø0.329 ( ) 34.5 20 1.358 0.787 When “n” units are installed horizontally in series When “n” units are installed vertically in series 31 1.220 × n + 3.5 0.138 × (n-1) A 0 55 2.165 or more 8.5 0.335 50 1.969 33.4 1.315 33.4 1.315 31−0.4 0 1.220 −0.016 0 31−0.4 0 1.220 −0.016 31 1.220 × n + 3.5 0.138 × (n-1) Panel thickness dimension 1 to 3 mm 0.039 to 0.118 in 55 2.165 or more Connector Note: The panel thickness should be 1 to 3 mm 0.039 to 0.118 in. Note: The panel thickness should be 1 to 3 mm 0.039 to 0.118 in. (52 2.047 max) View A Material: Polyacetal (Panel mounting bracket) Polycarbonate (Front protection cover) CN-14A(-R)-C□ Connector attached cable (Optional, CN-14A-C2 is attached to the sensor) L ( 35 1.378 (0.3158 ) ) 50 (1.969 ) ø3.7 ø0.146 cable Model No. (0.3158 ) Cable length L (mm in) CN-14A(-R)-C1 1,000 39.370 CN-14A(-R)-C2 2,000 78.740 CN-14A(-R)-C3 3,000 118.110 CN-14A(-R)-C5 5,000 196.850 11 Pressure Sensor Lineup Higher precision, more advanced function Dual Display Digital Pressure Sensor   For gas Detection of liquid pressure Head-separated Dual display Digital Pressure Sensor  For gas & liquid     DP-100 SERIES Ver.2 Conforming to EMC Directive Certification of Recognition Certification [DP-101 (A) / 102 (A) only] •• Dual-screen 3-color display (red, green, orange) for added ease of operation. •• Wide variation of pressure ports. •• Provided with 2 outputs (standard type). •• Provided with analog output or external input (multi-function type). •• Provided with copy function for reduced man-hours and human error. •• Oil-free type also available for prevention of entry of oil or grease in air pipes. •• Compound pressure types (for low pressure / for high pressure) are available. DPC-L100 SERIES DPH-L100 SERIES Conforming to EMC Directive •• High-precision liquid / air pressure detection and excellent operability. •• Compact stainless steel body withstands pressure of up to 50 MPa. •• Oil-less, single diaphragm structure. •• Mounted with throttle to achieve high resistance to pressure surge. •• Standalone use of sensor head is possible. •• Provided with 2 outputs (analog voltage and current). •• Compound pressure type and positive pressure type are available. Installation on a panel or moving part possible Head-separated Dual Display Digital Pressure Sensor   For gas Multi-unit connection and network communication supported Head-separated Dual Display Digital Pressure Sensor   For gas     DPC-100 SERIES DPH-100 SERIES Conforming to EMC Directive Certification of Recognition •• High response speed of 500 μs. •• Automatic recognition of sensor head without initial setting. •• Sensor head can be installed easily using an Allen wrench. •• Standalone use of sensor head is possible. •• Provided with 2 outputs (analog voltage and current). •• Compound pressure type, positive pressure type and negative pressure type are available. DPS-400 SERIES DPH-100 SERIES Conforming to EMC Directive •• Ultra-high response speed of 150 μs. •• Network communication is possible. •• Allows connection of up to 16 units and copying of settings. •• One-touch cable for reduced wiring work. •• Sensor head can be installed easily using an Allen wrench. •• Standalone use of sensor head is possible. •• Provided with 2 outputs •• Compound pressure type, positive pressure type and negative pressure type are available. Disclaimer The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be regarded as granting of a license to use our products in the described applications. We do NOT warrant that we have obtained some intellectual properties, such as patent rights, with respect to such applications, or that the described applications may not infringe any intellectual property rights, such as patent rights, of a third party. Please contact: 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Global Sales Department ■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global All Rights Reserved © No. CE-DP0-10 June, 2015 Specifications are subject to change without notice. 2015 Printed in Japan
DP-001-J 价格&库存

很抱歉,暂时无法提供与“DP-001-J”相匹配的价格&库存,您可以联系我们找货

免费人工找货