For gas
Digital Pressure Sensor
DP-0 SERIES
Conforming to
EMC Directive
Simpler and
Easier to Use
2015.06
panasonic.net/id/pidsx/global
DP-0
Simple & Easy Operation
Two levels of setting mode for
easy operation of essential
functions
The “RUN mode” is for threshold value setting, zero point
adjustment and key lock setting / release setting, and the
“detailed setting mode” allows for basic settings for sensor
operation. The two-level setting mode configuration enables
easy and immediate use of the product.
Detailed setting mode
Pressure unit
setting mode
RUN mode
Operation
setting mode
NO / NC
setting mode
• Threshold value setting
• Zero point adjustment
• Key lock setting / release
Response time
setting mode
Display color
setting mode
Settings
initializing mode
Main menu for detailed setting mode
Operation setting mode*
NO / NC setting mode
Response time setting mode
Display color setting mode
Select from EASY mode,
hysteresis mode or window
comparator mode.
Set the comparative output
operation to NO or NC.
Select the response time from
2.5 ms, 25 ms or 250 ms.
Select the comparative output ON /
OFF display color and the normal
display color from red or white.
* For details of operation setting mode, see page 4.
Functional Design
Crisp
clicking feel
Black body for enhanced visibility
of LCD display
The unit body is completely black to make the LCD display
easier to see.
Firm and crisp clicking feel
The buttons offer firm and crisp clicking feel for smooth and
reliable setting operations.
2
DP-0
Simp le
DP-0
Redesigned for improvement of pressure
sensor usability from ground up
Eas y Setti ng
High-Quality LCD Display
Pressure / setting display
Simple and highly
visible display
Comparative output
ON / OFF mark
Key lock mark
OVER mark
Pressure unit display
Low pressure type: kPa, kgf/cm2, bar, psi, mmHg
High pressure type: MPa, kgf/cm2, bar, psi
RUN mode
Detailed setting mode
The LCD offers a wide viewing angle
so the display is easy to see even from
an oblique angle. The alphanumeric
display (12-segment display), key lock
mark and OVER mark further enhance
the recognition of display.
Selection of display color from red or white
The display color can be selected from red or white in
accordance with the output operation. Since the detailed
setting mode display is pink (unchangeable), the pressure
sensor status can be easily recognized by color.
Display color
setting
Mode
Red for ON, white for OFF
White for ON, red for OFF
RUN mode
Comparative output ON
Comparative output OFF
Red
White
White
Red
Detailed setting
mode
Red
White
Red in normal status
White in normal status
Pink
Compact & Light Weight Design
Extra-short depth and light weight
The unit body measures only 24.9 mm 0.980 in in depth to
allow installation in a narrow space. The main unit weighs
only about 25 g. The lightweight unit means minimal load
when mounted on a moving part such as a robot arm.
Comparison with Depth
: Approx.
previous model dimension
Main
unit
(DP-100 series standard
: Approx.
pressure port type)
weight
41% shorter!
38% lighter!
Previous model
DP-0 series
Approx.
25 g
24.9 mm
0.980 in
(DP-100 series standard pressure port type)
< Actual size >
Approx.
40 g
42.5 mm 1.673 in
3
DP-0
High pressure type
Low pressure type
Low Pressure Type and High Pressure Type Available
Two types to choose from
according to applications
Applications
The low pressure type can be used with positive or negative
pressure, while the high pressure type is suitable for positive
pressure of up to 1 MPa.
Suction confirmation for
electronic parts
Reference pressure check
Ideal for applications such
as suction. No
misoperations due to
vacuum breakdown occur.
−100 kPa
Low
pressure type
0 kPa
DP-001□
High
pressure type
Ideal for applications such
as checking reference
100 kPa pressure. Can also be
used for simple suction.
1 MPa
DP-002□
Three Output Modes
Equipped with three output modes for use in a wide range of applications
H (Hysteresis)
0
Comparative ON
output
OFF
H: 4 digits (fixed) (10 digits or more when using psi unit)
4
(3) Window comparator mode
This mode is used for setting comparative output
ON and OFF at pressures within the setting
range.
P-2
P-1
0
Comparative ON
output
OFF
H (Hysteresis)
H: 2 digits or more (5 digits or more when using psi unit)
Pressure
Pressure
P-1
(2) Hysteresis mode
This mode is used for setting comparative output
hysteresis to the desired level and for carrying
out ON / OFF control.
Pressure
(1) EASY mode
This mode is used for comparative output ON /
OFF control.
P-2
H (Hysteresis)
H (Hysteresis)
P-1
0
Comparative ON
output
OFF
H: 4 digits or more (10 digits or more when using psi unit)
DP-0
Designed for Easy Installation
Tight installation is
possible
Panel mounting
bracket
An exclusive mounting bracket that is
suitable for 1 to 3 mm 0.039 to 0.118 in
panel thickness is available.
Panel mounting bracket
MS-DP1-8
Neat and
space
saving
Front protection cover
MS-DP1-3
Tight insta
llation is
Exclusive
mounting bracket
possible
A single
mounting hole
Supports tight
installation
MS-DP1-1
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory for MS-DP1-1)
Space savings can also be achieved
even when an L-shaped mounting
bracket is used.
Tight installation
is possible
Ceiling mounting
Floor mounting
MS-DP1-5
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory for MS-DP1-5)
Positioning bosses for easier
mounting bracket installation
Connection
cable
Cable can be connected
with one-touch
Connector attached cable (2 m 6.562 ft),
as an accessory, can be connected
easily with one-touch connection.
Connection cable *
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available.
Rear mounting
Types without connector attached
cable are also available DP-00□- J
Commercially-available connectors can be used for cable
connections. Cables in required length can be used, so this
contributes to reduction in waste of unwanted cables.
Environmentally
friendly
Commercially-available
parts can be used!
Refer to p.6 for recommended commercially-available connectors.
5
DP-0
ORDER GUIDE
Model No.
DP-00 1 - P - J
Rated pressure range
Cable
1 : −100.0 to +100.0 kPa (Low pressure type)
2 : 0.000 to +1.000 MPa (High pressure type)
None : Connector attached cable 2 m 6.562 ft
J : Type without connector attached cable
Comparative output
None : NPN output type
P : PNP output type
Type
Appearance
Rated pressure range
Low pressure
type
High pressure
type
−100.0 to +100.0 kPa
*CN-14A-C2
(Connector attached cable
2 m 6.562 ft ) is attached.
0.000 to +1.000 MPa
Type without connector attached cable
Model No.
Pressure port
DP-001
DP-001-P
DP-002
DP-002-P
Comparative output
NPN open-collector transistor
M5 female thread
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
Accessory
Type without connector attached cable CN-14A-C2 is available. When ordering
this type, suffix “-J” to the end of Model No.
(e.g.) Type without connector attached cable of DP-001-P is “DP-001-P-J”
•• CN-14A-C2 (Connector attached cable 2 m 6.562 ft)
OPTIONS
Designation
Model No.
CN-14A-C1
Connector
attached cable
Connector
attached cable
(Flexible cable)
Description
Length: 1 m 3.281 ft
CN-14A-C2 (Note) Length: 2 m 6.562 ft
CN-14A-C3
Length: 3 m 9.843 ft
CN-14A-C5
Length: 5 m 16.404 ft
CN-14A-R-C1
Length: 1 m 3.281 ft
CN-14A-R-C2
Length: 2 m 6.562 ft
CN-14A-R-C3
Length: 3 m 9.843 ft
0.2 mm2 4-core cabtyre cable with
connector on one end
Cable outer diameter: ø3.7 mm
ø0.146 in
0.2 mm2 4-core flexible cabtyre
cable with connector on one end
Cable outer diameter: ø3.7 mm
ø0.146 in
Length: 5 m 16.404 ft
CN-14A
Set of 10 housings and 40 contacts
MS-DP1-1
Allows sensors to be installed on the flooring or ceiling.
Multiple sensors can also be mounted closely.
MS-DP1-5
Allows sensors to be installed on the wall. Multiple sensors
can also be mounted closely.
Panel mounting
bracket
MS-DP1-8
Allows installation to panels with thickness of 1 to 3 mm 0.039
to 0.118 in. Multiple sensors can also be mounted closely.
Front protection
cover
MS-DP1-3
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket)
Sensor mounting
bracket
Note: The connector attached cable CN-14A-C2 is supplied with the DP-0 series.
6
Contact: SPHD-001T-P0.5,
Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details
of the recommended products.
Recommended crimping tool
CN-14A-R-C5
Connector
Recommended connector
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details
of the recommended products.
DP-0
SPECIFICATIONS
Model No.
Type
Item
Low pressure
High pressure
NPN output
DP-001
DP-002
PNP output
DP-001-P
DP-002-P
Type of pressure
Rated pressure range
Set pressure range
Pressure withstandability
Gauge pressure
−100.0 to +100.0 kPa
0.000 to +1.000 MPa
−101.0 to +101.0 kPa
−1.030 to +1.030 kgf/cm2
−1.010 to + 1.010 bar
−14.65 to +14.65 psi
−756 to +756 mmHg
−0.010 to +1.010 MPa
−0.1 to +10.30 kgf/cm2
−0.1 to + 10.10 bar
−0.1 to +146.5 psi
500 kPa
1.5 MPa
Applicable fluid
Selectable unit
Supply voltage
Air, non-corrosive gas
Low pressure type: kPa, kgf/cm2, bar, psi, mmHg
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption
Comparative output
Output operation
30 mA or less
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less
(between comparative output and 0 V)
• Residual voltage: 2 V or less (at 50 mA sink current)
Response time
Minimum 2 digits (variable)
±0.2 % F.S. (within ±4 digits)
±0.4 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Short-circuit protection
Display
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
Displayable
pressure range
Environmental resistance
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less
(between comparative output and +V)
• Residual voltage: 2 V or less (at 50 mA source current)
Selectable either NO or NC by key operation
Hysteresis
Repeatability
High pressure type: MPa, kgf/cm2, bar, psi
−101.0 to +101.0 kPa
−1.030 to +1.030 kgf/cm2
−1.010 to + 1.010 bar
−14.65 to +14.65 psi
−756 to +756 mmHg
−0.010 to +1.010 MPa
−0.1 to +10.30 kgf/cm2
−0.1 to + 10.10 bar
−0.1 to +146.5 psi
Protection
Ambient temperature
Ambient humidity
Voltage withstandability
IP40 (IEC)
0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: -10 to +60 °C +14 to +140 °F
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
Shock resistance
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each
Pollution degree
2
Overvoltage category
I
Usable altitude
Temperature characteristics
(+20°C standard)
Grounding method
Pressure port
Material
Weight
Accessory
2,000 m 6,562 ft or less
+10 to +40°C +50 to +104°F: Within ±1 % F.S.
0 to +50°C 32 to +122°F: Within ±2.5 % F.S.
+10 to +40°C +50 to +104°F: Within ±2 % F.S.
0 to +50°C 32 to +122°F: Within ±5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated),
Mounting threaded part: Brass, O-ring: Nitrile rubber (NBR), Key section: Polycarbonate
25 g approx.
CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1 pc.
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
7
DP-0
I/O CIRCUIT AND WIRING DIAGRAMS
NPN output type
I/O circuit diagram
Terminal arrangement diagram
Terminal No.
Color code of connector attached cable
(Brown) +V
1
Sensor circuit
D1
3
D2
Tr
2
(White) Not connected (Note) Load
(Black) Comparative output
+
−
50 mA MAX.
ZD
2
3
4
Terminal
No.
(Blue) 0 V
4
Internal circuit
1
12 to 24 V DC
±10 %
Designation
Users’ circuit
+V
Note: Open or, connect to 0 V.
Comparative output
Symbols…D1, D2: Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr: NPN output transistor
Not connected (Note)
0V
Note: Open or, connect to 0 V.
PNP output type
Terminal arrangement diagram
I/O circuit diagram
Terminal No.
Color code of connector attached cable
Sensor circuit
D1
Tr
(Brown) +V
1
ZD
50 mA MAX.
D2
2
3
4
(Black) Comparative output
(White) Not connected (Note) Load
+
−
(Blue) 0 V
Internal circuit
1
12 to 24 V DC
±10 %
2
3
Terminal
No.
Users’ circuit
8
Designation
+V
Note: Open or, connect to 0 V.
Symbols…D1, D2: Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr: PNP output transistor
4
Comparative output
Not connected (Note)
0V
Note: Open or, connect to 0 V.
DP-0
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device for
personnel protection.
• In case of using sensing devices for personnel
protection, use products which meet laws and
standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region or
country.
• This product is used for noncorrosive gas. The
product shall not be used for liquid or corrosive
gas. Never use fluids having inflammability,
toxicity, etc., that affect the human body, either.
Part description
Digital display unit
Connecting
connector
OFF mark
OVER mark
Pressure port
(M5 female thread)
Mode
selection key
How to connect
•• Insert the cable with connector
CN‑14A(‑R)‑C□ into this product’s
connection connector section as shown
in the right figure.
Release lever
How to disconnect
•• Pressing the release lever of the cable
with connector, pull out the connector.
Cable with connector
CN-14A(-R)-C□
Note: Do not pull by holding the cable without pressing the release lever, as
this can cause cable break or connector break.
Factory setting
ON mark
Key lock mark
Connection
Setting value UP key
Setting value DOWN key
Type
Low pressure type
Operation setting
NO / NC setting
NC
NO
Threshold value
−50.0
0.500
Pressure unit
kPa
MPa
Display color
Red when ON, White when OFF
Response speed
Piping
•• When using this product, connect a joint available in the market
to the pressure port. At the time, the tightening torque should be
1.0 N·m or less.
•• Use sensor mounting bracket MS‑DP1‑1 prepared independently.
When mounting this product with sensor mounting bracket, etc.,
the tightening torque should be 0.5 N·m or less.
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory with MS-DP1-1)
Sensor mounting
bracket MS-DP1-1
(Optional)
•• Panel fittings MS‑DP1‑8 (optional) and front cover MS‑DP1‑3
(optional) are available.
•• For the method for mounting panel fittings, refer to the instruction
manual that came with the MS‑DP1‑8.
Wiring
•• Make sure that the power supply is OFF while performing the
wiring operation.
•• Verify that the supply voltage variation is within the rating.
•• If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power supply
is connected to an actual ground.
•• In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the
frame ground (F.G.) terminal of the equipment to an actual
ground.
•• When extending the cable, use a cable whose conductor crosssectional area is 0.3 mm2 or more. The cable can be extended to
up to 10 m 32.808 ft in total length.
•• Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause
malfunction due to induction.
•• Do not apply stress directly to the connection cable leader or to
the connector.
2.5 ms
Error indication
Error indication
Mounting
High pressure type
EASY mode
Description
Remedy
The load is short-circuited
causing an overcurrent to
flow.
Turn OFF the power and
check the load.
Pressure is applied during
zero point adjustment.
Applied pressure at the
pressure port should be
brought to atmospheric
pressure and zero-point
adjustment should be done
again.
The applied pressure
exceeds the upper limit of
the displayed pressure
range.
The applied pressure
exceeds the lower limit
(back pressure) of the
displayed pressure range.
Applied pressure range
should be brought within
the rated pressure range.
When other error massage is displayed, contact us.
Others
•• This product has been developed / produced for industrial use
only.
•• The product shall be used only within the rated pressure range.
•• Do not apply pressure exceeding the pressure resistance.
Otherwise, destruction of diaphragm occurs, preventing the
product to perform normal operation.
•• Do not use during the initial transient time (0.5 sec.) after the
power supply is switched ON.
•• The specification may not be satisfied in a strong magnetic field.
•• This product is suitable for indoor use only.
•• Take care that strong impact such as fall is not given to this
product. Otherwise, it may be destroyed.
•• Avoid dust, dirt, and steam.
•• Take care that the product does not come into contact with
organic solvents such as thinner.
•• Take care that the product does not come into contact with oil or
grease.
•• Take care that the product does not come into contact with
strong acid or alkaline.
•• Do not insert wire into the pressure port. Otherwise, destruction
of diaphragm occurs, preventing the product to perform normal
operation.
9
DP-0
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from the website.
DP-00□
Sensor
24.9 0.980
30 1.181
20 0.787
Connector
20 0.787
4.9 0.193
Display
30
1.181
ø8.35
ø0.329
Setting value DOWN key
Mode selection key
2-ø2.5 0.098, 5 0.197 deep
20
0.787
M5 female thread, 4 0.157 deep
1.3 0.051
2-M3 female thread, 4 0.157 deep
Setting value UP key
MS-DP1-1
Sensor mounting bracket (Optional)
ø2.3
ø0.091
22
0.866
9.5
14.5
0.571 0.374
2-R2.1 R0.083
1
0.039
4.2
0.165
21
0.827
30
1.181
20
0.787
13
0.512
20
R13
0.787 R0.512
t2
t 0.079
Assembly dimensions
14.5
9.5 0.571
0.374
2-R2.1 R0.083
4.2
0.165
2-ø3.5 ø0.138
24.9
0.98
4.9 0.193
5.3
(0.209
)
45
(1.772
)
ø8.35 ø0.329
30
1.181
5.5 44
0.217 1.732
20
0.787
20
0.787
45
1.772
1.3
0.051
15
0.591
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
30
t 2 1.181
t 0.079
30 1.181
MS-DP1-5
Sensor mounting bracket (Optional)
Assembly dimensions
22.75
0.896
4.5
0.177
R6.75
R0.266
29.5
1.161
20
0.787
ø4.5
ø0.177
28
1.102
16
0.630
8.5 0.335
24.9
0.980
4.9
0.193
44.5
30 1.752
1.181
20
0.787
13.5
0.531
20
0.787
2-ø3.5 ø0.138
t 1.5
t 0.059
Material: Stainless steel (SUS304)
Two M3 (length 6 mm 0.236 in) screws with
washers are attached.
10
49.5
(1.949
)
ø4.5
ø0.177
ø8.35 ø0.329
49.5
1.949
20
0.787 28.5
1.122
20
0.787
29.5
1.161
30
1.181
4.5
0.177
1.3
0.051
26.5
1.043
48
1.890
t 1.5
t 0.059
DP-0
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from the website.
MS-DP1-8 MS-DP1-3
Panel mounting bracket (Optional), Front protection cover (Optional)
Mounting drawing with DP-00□
Panel cut-out dimensions
When 1 unit is installed
0
31−0.4
0
1.220 −0.016
0
0
31−0.4 1.220 −0.016
(39.3 1.547)
34.5 1.358
Front protection
cover
11
0.433
7.2 12.8
0.283 0.504
4.9 0.193
ø8.35 ø0.329
( )
34.5 20
1.358 0.787
When “n” units are installed
horizontally in series
When “n” units are installed
vertically in series
31 1.220 × n + 3.5 0.138 × (n-1)
A
0
55 2.165
or more
8.5
0.335
50 1.969
33.4 1.315
33.4
1.315
31−0.4
0
1.220 −0.016
0
31−0.4
0
1.220 −0.016
31 1.220 × n +
3.5 0.138 × (n-1)
Panel thickness
dimension 1 to 3 mm
0.039 to 0.118 in
55 2.165
or more
Connector
Note: The panel thickness should be
1 to 3 mm 0.039 to 0.118 in.
Note: The panel thickness should be
1 to 3 mm 0.039 to 0.118 in.
(52 2.047 max)
View A
Material: Polyacetal (Panel mounting bracket)
Polycarbonate (Front protection cover)
CN-14A(-R)-C□
Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
L
(
35
1.378
(0.3158 )
)
50
(1.969
)
ø3.7 ø0.146 cable
Model No.
(0.3158 )
Cable length L (mm in)
CN-14A(-R)-C1
1,000 39.370
CN-14A(-R)-C2
2,000 78.740
CN-14A(-R)-C3
3,000 118.110
CN-14A(-R)-C5
5,000 196.850
11
Pressure Sensor Lineup
Higher precision, more advanced function
Dual Display Digital Pressure Sensor For gas
Detection of liquid pressure
Head-separated Dual display Digital Pressure Sensor For gas & liquid
DP-100 SERIES Ver.2
Conforming to
EMC Directive
Certification of
Recognition
Certification
[DP-101 (A) / 102 (A) only]
•• Dual-screen 3-color display
(red, green, orange) for added
ease of operation.
•• Wide variation of pressure ports.
•• Provided with 2 outputs
(standard type).
•• Provided with analog output or
external input (multi-function
type).
•• Provided with copy function for
reduced man-hours and
human error.
•• Oil-free type also available for
prevention of entry of oil or
grease in air pipes.
•• Compound pressure types (for
low pressure / for high
pressure) are available.
DPC-L100 SERIES DPH-L100 SERIES
Conforming to
EMC Directive
•• High-precision liquid / air
pressure detection and
excellent operability.
•• Compact stainless steel body
withstands pressure of up to
50 MPa.
•• Oil-less, single diaphragm
structure.
•• Mounted with throttle to
achieve high resistance to
pressure surge.
•• Standalone use of sensor
head is possible.
•• Provided with 2 outputs
(analog voltage and current).
•• Compound pressure type and
positive pressure type are
available.
Installation on a panel or moving part possible
Head-separated Dual Display Digital Pressure Sensor For gas
Multi-unit connection and network communication supported
Head-separated Dual Display Digital Pressure Sensor For gas
DPC-100 SERIES DPH-100 SERIES
Conforming to
EMC Directive
Certification of
Recognition
•• High response speed of
500 μs.
•• Automatic recognition of
sensor head without initial
setting.
•• Sensor head can be installed
easily using an Allen wrench.
•• Standalone use of sensor
head is possible.
•• Provided with 2 outputs
(analog voltage and current).
•• Compound pressure type,
positive pressure type and
negative pressure type are
available.
DPS-400 SERIES DPH-100 SERIES
Conforming to
EMC Directive
•• Ultra-high response speed of
150 μs.
•• Network communication is
possible.
•• Allows connection of up to 16
units and copying of settings.
•• One-touch cable for reduced
wiring work.
•• Sensor head can be installed
easily using an Allen wrench.
•• Standalone use of sensor
head is possible.
•• Provided with 2 outputs
•• Compound pressure type,
positive pressure type and
negative pressure type are
available.
Disclaimer
The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be regarded as
granting of a license to use our products in the described applications. We do NOT warrant that we have obtained some intellectual properties, such as patent
rights, with respect to such applications, or that the described applications may not infringe any intellectual property rights, such as patent rights, of a third party.
Please contact:
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Global Sales Department
■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591
panasonic.net/id/pidsx/global
All Rights Reserved ©
No. CE-DP0-10 June, 2015
Specifications are subject to change without notice.
2015
Printed in Japan