PRESSURE SENSOR
DIGITAL PRESSURE SENSOR
DP-100
SERIES
Conforming to
EMC Directive
UL
recognition pending
A New Global Standard
Dual display for the digital pressure sensors of the future
m
Industry first. Dual 3-color display makes operation easier!
The dual display means that the ‘current value’ and the ‘threshold value’ can be displayed at the same
time to improve ease of operation and visual checking.
Introducing a new standard in digital pressure sensor technology.
m As of November 2005 and based on research conducted by SUNX for 30 mm 1.181 in square sized digital pressure sensors.
A new global standard
‘Current value’ and ‘threshold value’
can be checked at the same time!
Dual display allows direct
setting of threshold value
Threshold value setting method
Equipped with a 30 mm 1.181 in square
compact-sized dual display. Because the
current value and the threshold value
can be checked at the same time, the
threshold value can be set and checked
smoothly without having to switch screen
modes. ON / OFF operations are still
carried out while the threshold values
are being set, so setting to the same
sensitivity as dial control-type sensors is
possible. And naturally a key lock
function is also equipped.
Previous model with single display
-91.8
Note current value
Adjust threshold value Return to RUN operation
DP-100 with dual display
Simply press a button
during RUN operation
Man-hours reduced by
3/
4
3-color display (Red, Green, Orange)
Readable digital display!
The main display changes color in line with changes in the
status of output ON / OFF operation, and it also changes color
while setting is in progress. The sensor status can therefore be
understood easily, and operating errors can be reduced.
12 segments are used and an alphanumeric display has been
adopted. This improves visual checking of letters and numbers.
OFF: Green (or Red)
ON: Red (or Green)
SET: Orange
Main
Display
During normal operation
1
Operate MODE key
During setting
Dual Display
Direct setting
Current value
Threshold value
Dir
ns
tting m
t se
ea
ec
Works like a dial
control type sensor
Main display
Comparative Output 1 operation indicator
Comparative Output 2 operation indicator
Multi-function type: Analog voltage output
opertaion indicator
Sub display
Mode selection key
Decrement key
Increment key
2
Copy function lets work be carried out accurately and quickly
Copy function reduces man-hours and human error
Sensors can be connected to a master sensor one by one, and a copy of the
setting details for the master sensor can be transmitted as data to the other
sensors. If making the same settings for multiple sensors, this prevents setting
errors from occurring with the other sensors and also reduces the number of
changes required to instruction manuals when equipment designs are
changed.
Setting details can be copied.
Copying via wiring
Details transmitted
Master sensor
Slave sensor
Power supply
V
Details received
Detail
s cop
Advantage
1
V
0V
ied
0V
Comparative output 1
Comparative output 1
Comparative output 2
Comparative output 2
Setting man-hours are reduced and sensor setting time is shortened.
4th equipment:
5 minutes
approx.
3rd equipment:
5 minutes
approx.
2nd equipment:
5 minutes
approx.
1st equipment:
5 minutes
approx.
Number of pressure sensor: For 1 per equipment and 4 per line
The setting details for the master sensor are
retained, so continuous copying is possible!
For 2nd and subsequent lines, only the data
transmission time is needed.
4th equipment:
20 minutes 3rd equipment:
approx. 2nd equipment:
1st equipment:
Sensor setting time:
Master
sensor
5 minutes
approx.
4th equipment:
20 minutes 3rd equipment:
approx. 2nd equipment:
1st equipment:
Sensor setting time:
Sensor setting time:
20 minutes approx. 5 minutes 20 seconds approx. 20 seconds approx.
Previously
Advantage
2
DP-100, 1st line
DP-100, 2nd line
Human operating error is reduced.
Because all details are copied automatically, it prevents problems occurring as a result
of human error.
Instruction manuals can be updated easily when changes occur to equipment design!
3
Setting is smooth and easy
The sensor’s setting operation mode has a 3-level
configuration to suit the frequency of use.
The setting levels are clearly separated into ‘RUN mode’ for operation
settings that are carried out daily, ‘MENU SETTING mode’ for basic settings,
and ‘PRO mode’ for special and detailed setting. These make setting
operations easy to understand and easy to carry out.
RUN mode
Settings such as threshold value
adjustment and key lock operation
can be carried out while the
sensor is operating.
RUN mode
Simple setting
MENU SETTING mode
MENU SETTING mode
Basic settings such as output
mode setting and NO / NC
switching can be carried out.
PRO mode
Special and
detailed setting
PRO mode
High-level function settings such
as hysteresis adjustment and the
copy function can be carried out.
Display is orange while setting is in progress
The display appears in red and green during RUN operation, but it changes to orange while setting is in progress, so that the sensor status
can be viewed at a glance.
RUN operation
RUN mode
While setting
MENU SETTING mode
PRO mode
or
Red or green when output is ON / OFF
Orange while setting is in progress
Default settings that can be used straight away
Buttons with good clicking touch
Easy-to-use default settings are provided for applications that are
used frequently by pressure sensors. The default settings for low
pressure types are ideal for suction checking applications, and those
for high pressure types are ideal for checking reference pressure.
The buttons have a good clicking touch,
allowing smooth setting.
Low pressure type
Comparative output 1
Hysterisys 3digits
ON
High pressure type
Comparative output 1
Ideal for
checking
suction
Hysterisys 3digits
Ideal for
checking
reference
pressure
OFF
100 kPa
The clicking feeling is
transmitted even through gloves.
50 kPa
Reset function
0 kPa
0 MPa
0.5 MPa
1 MPa
If a problem ever occurs with the sensor settings, they can be
returned to the default settings.
4
Full range of performance and functions in a compact body
All models in the line-up are compound
pressure types
No sensor settings are required to switch between positive pressure
and negative pressure, so that the number of registered part
numbers can be decreased.
Realizes high performance
Low pressure type
The low pressure type displays measurements in 0.1 kPa at a
resolution of 1/2000 and has a response time of 2.5 ms (variable up
to 5,000 ms), 0.5 % F.S. temperature characteristics and 0.1 %
F.S. repeatability, giving it high performance.
Ideal for applications such
as suction. No misoperations due to vacuum
breakdown occur.
100 kPa
For low
pressure
For high
pressure
0 kPa
DP-101
Resolution: 1/2,000
Response time: 2.5 ms
Temperature characteristics: 0.5 % F.S.
Repeatability: 0.1 % F.S.
100 kPa
Ideal for applications such
as checking reference
pressure. Can also be used
for simple suction.
1 MPa
Displays measurements in 0.1 kPa
DP-102
Equipped with independent dual output
Standard type
Equipped with two independent comparative outputs, and separate
sensing modes can be selected for each of them. One of the
comparative outputs can even be used for alarm output. In addition,
if an output is not being used, it can be disabled.
Three output modes are suitable for a wide
range of applications
1
EASY mode
This mode is used for comparative output ON / OFF control.
ON
Comparative output 1
EASY mode
OFF
100 kPa
Comparative output
0
ON
OFF
H: Fixed
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) ‘
’ appears in the sub display for comparative output 1,
and ‘
’ appears for comparative output 2.
2
Vacuum breakdown checking
P-1
0 kPa
ON
Comparative output 1
hysteresis mode
OFF
Hysteresis mode
This mode is used for setting comparative output hysteresis to
the desired level and for carrying out ON / OFF control.
P-2
● Reference pressure alarm output is possible during
reference pressure checking!
Reference
pressure
checking
ON
Comparative output 2
EASY mode
OFF
Lo-1
Hi-1
P-2
H (Hysteresis)
H: 1 digit or more
Note: ‘
’ or ‘
output 1, and ‘
’ appears in the sub display for comparative
’ or ‘
’ appears for comparative output 2.
Window comparator mode
This mode is used for setting comparative output ON and OFF
at pressures within the setting range.
Pressure
Alarm output
Hi
Lo
0
ON
Comparative output
OFF
3
0 kPa
H (Hysteresis)
P
Suction checking
Pressure
ON
Comparative output 2
EASY mode
OFF
Pressure
● Vacuum breakdown can also be checked during
suction applications!
H (Hysteresis)
Hi
Lo
0
ON
Comparative output
OFF
H (Hysteresis)
H: Fixed
Notes: 1) Hysteresis can be fixed to one of eight different levels.
’ or ‘
’ appears in the sub display for comparative
2) ‘
output 1, and ‘
’ or ‘
’ appears for comparative output 2.
5
Switching is possible between analog voltage output and external input
Multi-function type
Multi-function type is available that allows selection of analog voltage output or external input (auto-reference / remote zero-adjustment).
This is suitable for multi-specification applications.
Comparative output
Analog voltage output
or
Select
External input
Multi-function type
ANALOG lights up
Low pressure type: 1 to 5 V
High pressure type: 0.6 to 5 V
Auto-reference /
remote zero-adjustment
Equipped with auto-reference / remote zero-adjustment functions Multi-function type
More precise pressure management is possible with a minimum of effort
If the reference pressure of the
device changes, the autoreference function partially shift
the
comparative
output
judgment level by the amount
that the reference pressure
shifts, and the remote zeroadjustment function can reset
the display value to zero via
external input. These functions
are ideal for places where the
reference pressure fluctuates
wildly, or where fine settings are
desired.
Without auto-reference and remote zero-adjustment functions
Comparative output: Window comparator mode
Hi-1 30, Lo-1 25
Fixed set value
40
NG?
30
Leak threshold level
25
20
OK
NG?
15
Variation in the filling pressure
Trial 1
Trial 2
Trial 3
Pressure
0
Time
Because the threshold level is fixed for conventional pressure sensors,
changes in the reference pressure result in wrong decisions.
With auto-reference function applied
With remote zero-adjustment function applied
Comparative output: Window comparator mode
Hi-1 0, Lo-1 5
Comparative output: Window comparator mode
Hi-1 0, Lo-1 5
Sets the absolute threshold level
Sets the absolute threshold level
Auto-reference input
Remote zero-adjustment input
The display is forced to ‘0’, and only the
filling pressure drop range is displayed.
The display remains at ‘30’ and
only the threshold level is changed.
30
30
OK
25
20
Threshold level after applying
auto-reference input
15
0
5
25
20
Threshold level after applying
remote zero-adjustment input
15
Threshold level before applying
remote zero-adjustment input
Threshold level before applying
auto-reference input
Trial 1
Pressure 0
5
Trial 1
Pressure 0
Auto-reference input value
Time
When auto-reference input is applied, the reference pressure ‘30’ is added
to the threshold level. If the reference pressure changes to ‘20’ or ‘40’, the
auto-reference input compensates for this every time by changing the
threshold level, so any variation in the filling pressure can be ignored.
OK
5
Displayed when remote zeroadjustment input is applied
Time
When remote zero-adjustment input is applied, the reference pressure is forced to ‘0’.
If the reference pressure changes to ‘20’ or ‘40’, the remote zero-adjustment input
adjusts the reference pressure to ‘0’ every time the reference pressure changes, so
any variation in the filling pressure can be ignored.
6
Other useful functions
Sub display can be customized
Setting details can be understood at a glance
The sub display can be set to indicate any other desired values or
letters apart from the threshold value. This eliminates the need for
tasks such as affixing a label to the device to indicate the normal
pressure value.
The DP-100 setting details appear in the digital display. Because the
settings are in numeric form that can be easily understood, it is
useful for times such as when receiving technical support by
telephone.
What are the check
codes for the setting?
The code on the main display is 3205.
The sub display reads 7011.
2nd digit: Setting status for
comparative output 2
3rd digit: Threshold value setting
1st digit: Setting status for
comparative output 1
4th digit: Display color setting
Indicates desired values and letters
5th digit: Response time
setting
8th digit: ECO mode setting
6th digit: Display unit setting
7th digit: Display refresh rate setting
Peak hold and Bottom hold functions
Energy-saving design! Equipped with an ECO mode
The peak values and bottom values for fluctuating pressures can be
displayed using the dual display.
This mode lowers the display luminance to cut power consumption
by approximately 30 %. The displays can also be turned off
completely to achieve a power saving of approximately 40 %.
Power consumption
Power consumption
Normal
Approx.
Approx.
ECO-STD 30 % less
ECO-FULL 40 % less
Current consumption for
24 V power supply: 25 mA or less
Current consumption for
24 V power supply: 20 mA or less
Blinks alternately
Current consumption for
24 V power supply: 35 mA or less
Response time can be changed
Display refresh rate can be varied
The response time can be changed in 10 levels from 2.5 ms to
5,000 ms. This prevents chattering and incorrect operation due to
sudden changes in pressure.
The display refresh rate for the digital displays can be changed to
one of three settings: 250 ms, 500 ms or 1,000 ms. Flickering of the
display can be reduced by making the display refresh rate longer.
Pressure
Temporary change due to fluctuation
Threshold value
Incorrect operation prevented
Output
7
ON
OFF
Installation is also easy!
Tight installation to panels is possible
An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039 to
0.236 in panel thickness is available.
Takes up
much
less space
Tight installation is possible
Front protection
cover available
MS-DP1-3
A single mounting hole!
● An exclusive mounting bracket (MS-DP1-1) that supports tight installation is available
Space savings can also be obtained if an L-shaped mounting
bracket is used.
Ceiling mounting
Tight installation is possible
Floor mounting
Positioning bosses for easier
mounting bracket installation
Cable can be connected with one-touch connection
The accessory connector attached cable (2 m 6.562 ft) can be
connected easily with one-touch connection.
● Types without connector attached
cable are also available
DP-10-J
Commercially-available connectors can be used for cable
connections. Only the required length of cable needs to be used,
which contributes to a reduced amount of wastage for unneeded
cable.
Environmentally
friendly
Connection cable m
Commercially-available
parts can be used!
m Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft
types are also available.
8
ORDER GUIDE
Type
Appearance
Rated pressure range
Asian
For high pressure
For high pressure
European
North American
For high pressure
NPN open-collector transistor
M5 female thread
PNP open-collector transistor
For high pressure
100.0 to 100.0 kPa DP-101A-E-P
0.100 to 1.000 MPa DP-102A-E-P
100.0 to 100.0 kPa
DP-101-N
NPN open-collector transistor
For low pressure
DP-101-N-P
PNP open-collector transistor
0.100 to 1.000 MPa
DP-102-N
For low pressure
Multi-function
R (PT) 1/8
male thread
100.0 to 100.0 kPa DP-101-E-P
0.100 to 1.000 MPa DP-102-E-P
For low pressure
Standard
Comparative output
M5 female thread
100.0 to 100.0 kPa DP-101A
0.100 to 1.000 MPa DP-102A
For low pressure
Multi-function
Pressure port
100.0 to 100.0 kPa DP-101
0.100 to 1.000 MPa DP-102
For low pressure
Standard
Model No.
Standard
For high pressure
mCN-14A-C2
Connector attached
cable 2 m 6.562 ft
is attached.
(
For low pressure
)
G 1/8
male thread
NPN open-collector transistor
M5 female thread
DP-102-N-P
NPT 1/8
male thread
PNP open-collector transistor
100.0 to 100.0 kPa
DP-101A-N
DP-101A-N-P
PNP open-collector transistor
0.100 to 1.000 MPa
DP-102A-N
NPN open-collector transistor
DP-102A-N-P
PNP open-collector transistor
NPN open-collector transistor
Multi-function
For high pressure
Types without connector attached cable
Types without connector attached cable are available. When ordering this type, add ‘-J’ at the end of the Model No.
Model No: DP-101-J, DP-101-E-P-J, DP-101-N-J, DP-101-N-P-J
DP-102-J, DP-102-E-P-J, DP-102-N-J, DP-102-N-P-J
Accessory
CN-14A-C2 (Connector attached cable 2 m 6.562 ft)
OPTIONS
Sensor mounting bracket
Designation
Connector
attached cable
Connector
Model No.
CN-14A-C1
CN-14A-C3
CN-14A-C5
CN-14A
On the market soon
Description
1 m 3.281 ft
3 m 9.843 ft
5 m 16.404 ft
• MS-DP1-1
M3 (length 6 mm 0.236 in)
screws with washers
0.2 mm2 4-core cabtyre cable
with connector on one end
Cable outer diameter: "3.7 mm "0.146 in
Set of 10 housings and 40 contacts
Sensor mounting
bracket
MS-DP1-1
Allows sensors to be installed to face in the direction of the
floor or ceiling. Multiple sensors can also be mounted closely.
Panel mounting
bracket
MS-DP1-2
Allows installation to panels with thickness of 1 to 6 mm
0.039 to 0.236 in.
Front protection
cover
MS-DP1-3
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket)
Accessory for
(MS-DP1-1
)
Sensor mounting
bracket
MS-DP1-1
Panel mounting bracket, Front protection cover
• MS-DP1-2
• MS-DP1-3
M3 (length 12 mm 0.472 in) tapping screw
(Accessory for MS-DP1-2)
Front protection cover
MS-DP1-3
Panel mounting bracket
MS-DP1-2
9
DP-100
SPECIFICATIONS
Item
Model No.
Type
Asian
European
North American (Note 2)
Standard
For low pressure
Multi-function
For high pressure
Set pressure range
Pressure withstandability
For high pressure
DP-101
DP-102
DP-101A
DP-102A
DP-101-E-P
DP-102-E-P
DP-101A-E-P
DP-102A-E-P
DP-101-N(-P)
DP-102-N(-P)
DP-101A-N(-P)
DP-102A-N(-P)
Type of pressure
Rated pressure range
For low pressure
Gauge pressure
100.0 to 100.0 kPa
100.0 to 100.0 kPa
1.020 to 1.020 kgf/cm2
1.000 to 1.000 bar
14.50 to 14.50 psi
750 to 750 mmHg
29.5 to 29.5 inHg
0.100 to 1.000 MPa
0.100 to 1.000 MPa
100 to 1,000 kPa
1.02 to 10.20 kgf/cm2
1.00 to 10.00 bar
14.6 to 145.0 psi
100.0 to 100.0 kPa
100.0 to 100.0 kPa
1.020 to 1.020 kgf/cm2
1.000 to 1.000 bar
14.50 to 14.50 psi
750 to 750 mmHg
29.5 to 29.5 inHg
0.100 to 1.000 MPa
0.100 to 1.000 MPa
100 to 1,000 kPa
1.02 to 10.20 kgf/cm2
1.00 to 10.00 bar
14.6 to 145.0 psi
500 kPa
1.5 MPa
500 kPa
1.5 MPa
Applicable fluid
Non-corrosive gas
Selectable unit
For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
12 to 24 V DC 10 % Ripple P-P 10 % or less
Supply voltage
Power consumption
Comparative output
Normal operation: 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less at STD (Current consumption 25 mA or less at 24 V supply voltage)
480 mW or less at FULL (Current consumption 20 mA or less at 24 V supply voltage)
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between comparative output and 0 V)
• Residual voltage: 2 V or less (at 100 mA sink current)
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between comparative output and V)
• Residual voltage: 2 V or less (at 100 mA source current)
NO / NC (selectable by key operation)
Output operation
Output modes
Hysteresis
Repeatability
Response time
EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable) (however, 2 digits when using psi unit)
0.1 % F.S. (within 2 digits) 0.2 % F.S. (within 2 digits) 0.1 % F.S. (within 2 digits) 0.2 % F.S. (within 2 digits)
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated
Short-circuit protection
ON voltage: 0.4 V DC or less ON voltage: 5 V toV DC
External input
Auto-reference function /
Remote zero-adjustment
function
OFF voltage: 5 to 30 V DC, or open OFF voltage: 0.6 V DC or less, or open
Input impedance: 10 kΩ approx. Input impedance: 10 kΩ approx.
Input time: 1 ms or more
Input time: 1 ms or more
Output voltage: 1 to 5 V DC
Zero point: within 3 V 5 % F.S.
Span: within 4 V 5 % F.S.
Linearity: within 1 % F.S.
Output impedance: 1 kΩ approx.
Analog voltage output
Display
Displayable pressure range
4 digits 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
100.0 to 100.0 kPa 2
100.0 to 100.0 kPa
0.100 to 1.000 MPa
0.100 to 1.000 MPa
1.020 to 1.020 kgf/cm2 100 to 1,000 kPa
1.020 to 1.020 kgf/cm
100 to 1,000 kPa
1.000 to 1.000 bar
1.000 to 1.000 bar
1.02 to 10.20 kgf/cm2
1.02 to 10.20 kgf/cm2
14.50 to 14.50 psi
14.50 to 14.50 psi
1.00 to 10.00 bar
1.00 to 10.00 bar
750 to 750 mmHg
750 to 750 mmHg
29.5 to 29.5 inHg
14.6 to 145.0 psi
29.5 to 29.5 inHg
14.6 to 145.0 psi
Orange LED
Environmental resistance
Indicator
Pollution degree
Ambient temperature
Ambient humidity
Voltage withstandability
Output voltage: 0.6 to 5 V
Zero point: within 1 V 5 % F.S.
Span: within 4.4 V 5 % F.S.
Linearity: within 1 % F.S.
Output impedance: 1 kΩ approx.
Orange LED
comparative output 2 operation indicator: Comparative output 1 operation indicator: Lights up when comparative output is ON,
(Comparative output 1 operation indicator,
)
Lights up when each comparative output is ON ) (Analog voltage output operation indicator: Lights up when setting
IP40 (IEC)
10 to 50
C 14 to 122
F, Storage: 10 to 60
C 14 to 140
F
35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 500 Hz frequency, 3 mm 0.118 in amplitude, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude, in X, Y and Z directions for two hours each)
Shock resistance
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each
Temperature characteristics
Within 0.5 % F.S. (at 20
C 68
F) Within 1 % F.S. (at 20
C 68
F) Within 0.5 % F.S. (at 20
C 68
F) Within 1 % F.S. (at 20
C 68
F)
Pressure port
Asian: M5 female thread R (PT) 1/8 male thread, European: M5 female thread G 1/8 male thread, North American: M5 female thread NPT 1/8 male thread
Material
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated), Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method
Cable extension
Weight
Accessories
Connector
Extension up to total 100 m 328.084 ft (less than 10 m 32.808 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable
Net weight: 40 g approx., Gross weight: 135 g approx.
CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were ambient temperature 20
C 68
F.
2) Model Nos. of North American standard type having the suffix ‘-P’
are PNP output type.
10
DP-100
I/O CIRCUIT AND WIRING DIAGRAMS
NPN output type
I/O circuit diagram
Color code of connector attached cable
1
D
Sensor circuit
Terminal arrangement diagram
Terminal No.
Standard type
2
Tr1
ZD1
3
Tr2
(Brown) V
(Black)
Load
Comparative output 1
Load
100 mA max.
(White) Comparative output 2
12 to 24 V DC
10 %
1
2
3
4
100 mA max.
ZD2
4
Internal circuit
(Blue) 0 V
Users’ circuit
Symbols D : Reverse supply polarity protection diode
ZD1, ZD2 : Surge absorption zener diode
Tr1, Tr2 : NPN output transistor
Terminal
Designation
1
2
V
Comparative output 1
3
Standard type: Comparative output 2
Multi-function type: Analog voltage output or External input
4
0V
Terminal No.
Multi-function type
5V
Sensor circuit
Color code of connector attached cable
(Brown) V
1
D1
Tr1
3
D2
1 kΩ
Tr2
2
(White) Analog voltage output
or External input
Load
(Black) Comparative output 1
12 to 24 V DC
10 %
100 mA max.
ZD1
4
Internal circuit
(Blue) 0 V
Users’ circuit
Symbols D1, D2 : Reverse supply polarity protection diode
ZD1 : Surge absorption zener diode
Tr1 : PNP input transistor
Tr2 : NPN output transistor
PNP output type
I/O circuit diagram
Terminal arrangement diagram
Terminal No.
Color code of connector attached cable
Standard type
1
(Brown) V
Sensor circuit
D
ZD1
100 mA max.
Tr1
2
ZD2
Tr2
(Black) Comparative output 1
100 mA max.
Load
3
(White) Comparative output 2
Load
(Blue) 0 V
12 to 24 V DC
10 %
4
Internal circuit
Users’ circuit
Symbols D : Reverse supply polarity protection diode
ZD1, ZD2 : Surge absorption zener diode
Tr1, Tr2 : PNP output transistor
Terminal No.
Color code of connector attached cable
Multi-function type
Sensor circuit
(Brown) V
1
D1
ZD1
Tr1
100 mA max.
2
1 kΩ
Tr2
3
D2
4
Internal circuit
(Black) Comparative output 1
(White) Analog voltage output Load
or External input
12 to 24 V DC
10 %
(Blue) 0 V
Users’ circuit
Symbols D1, D2 : Reverse supply polarity protection diode
ZD1: Surge absorption zener diode
Tr1 : PNP output transistor
Tr2 : NPN input transistor
11
1
2
3
4
Terminal
Designation
1
2
Comparative output 1
3
Standard type: Comparative output 2
Multi-function type: Analog voltage output or External input
4
0V
V
DP-100
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device for
personnel protection.
• In case of using sensing devices for personnel
protection, use products which meet regulations and
standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region or
country.
• The DP-100 series is designed for use with noncorrosive gas. It cannot be used with liquid or
corrosive gas.
Piping
• If connecting a commercially-available
coupling to the pressure port, attach a
12 mm 0.472 in spanner (14 mm 0.551 in
spanner for DP-100-E type) to the hexagonal
section of the pressure port to secure it, and
tighten at a torque of 9.8 Nm or less. If it is
tightened using excessive torque, it may
damage the coupling or the pressure port.
In addition, wrap sealing tape around the
coupling when connecting it to prevent leaks.
12 mm 0.472 in
spanner
Wiring
Others
• Make sure that the power supply is off while wiring.
• Verify that the supply voltage variation is within the rating.
• If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
• In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this sensor, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
• Do not run the wires together with high-voltage lines or power lines
or put them in the same raceway. This can cause malfunction due
to induction.
• Incorrect wiring will cause problems with operation.
• Use within the rated pressure range.
• Do not apply pressure exceeding the pressure withstandability
value. The diaphragm will get damaged and correct operation shall
not be maintained.
• Do not use during the initial transient time (0.5 sec. approx.) after
the power supply is switched on.
• Avoid dust, dirt, and steam.
• Take care that the sensor does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
• Do not insert wires, etc., into the pressure port. The diaphragm will
get damaged and correct operation shall not be maintained.
• Do not operate the keys with pointed or sharp objects.
Connection
RUN mode
Connector
attached cable
(CN-14A-C)
• Do not apply stress directly to the
connection cable leader or to the
connector.
• This is the normal operating mode.
Setting item
Conditions in use for CE conformity
• The DP-100 series is a CE conformity product complying with
EMC Directive. The harmonized standard with regard to immunity
that applies to this product is EN 61000-6-2 and the following
condition must be met to conform to that standard.
Condition
Description
Threshold value
setting
The threshold values for ON / OFF operation can be changed directly
by pressing the increment key (UP) and the decrement key (DOWN).
Zero-adjustment
function
This forces the pressure value display to be reset to zero when
the pressure port is open on the atmospheric pressure side.
Key lock function
Stops key operations from being accepted.
Peak hold /
bottom hold function
Displays the peak value and bottom value for fluctuating
pressure. The peak value appears in the main display,
and the bottom value appears in the sub display.
• The sensor should be connected less than 10 m 32.808 ft from the
power supply.
MENU SETTING mode
Mounting
• The MS-DP1-1 sensor mounting bracket is available separately,
and it should be used for mounting. When tightening the sensor to
the sensor mounting bracket, use a tightening torque of 0.5 Nm or
less.
• If the mode selection key is pressed and held for 2 seconds in
RUN mode, the mode will switch to MENU SETTING mode.
• If the mode selection key is pressed while a setting is being made,
the mode will switch to RUN mode. In this case, the settings that
have been changed will be entered.
Setting item
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory for MS-DP1-1)
Comparative output 1
output mode setting
Description
Sets the output mode for comparative output 1.
Comparative output 2 output mode
Sets the output mode for comparative output 2.
setting (standard type only)
Sensor mounting bracket
MS-DP1-1 (Optional)
• The MS-DP1-2 panel mounting bracket (optional) and the
MS-DP1-3 front protection cover (optional) are also available.
M3 (length 12 mm 0.472 in)
tapping screw
Analog voltage output /
external input switching
(multi-function type only)
Allows switching between analog voltage output
and auto-reference input / remote zero-adjustment input.
NO / NC switching
Sets normally open (NO) or normally closed (NC).
Response time setting
Sets the response time.
The response time can be selected from 2.5 ms,
5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms,
500 ms, 1,000 ms and 5,000 ms.
Display color switching
for main display
Allows the color for the main display to be changed.
The colors can be set to ‘red / green’ or ‘green / red’
to correspond to ON / OFF output, or it can be fixed
at ‘red’ or ‘green’ all the time.
Unit switching
Pressure unit can be changed.
(Accessory for MS-DP1-2)
Front protection cover
MS-DP1-3 (Optional)
Panel mounting bracket
MS-DP1-2 (Optional)
12
DP-100
PRECAUTIONS FOR PROPER USE
PRO mode
Table of codes
2nd digit
Code
• If the mode selection key is pressed and held for 5 seconds in
RUN mode, the mode will switch to PRO mode.
• If the mode selection key is pressed while a setting is being made,
the mode will switch to RUN mode. In this case, the settings that
have been changed will be entered.
1st digit
Sub display switching
Display refresh rate
switching
NC
Changes the information in the sub display
during RUN mode operation to the desired
alphanumeric display.
EASY
Sets the response time for EASY mode and
window comparator mode. (8 steps)
Linked display color
switching
(standard type only)
Allows the display color for the main display to
be switched in line with the output operation for
comparative output 1 or comparative output 2.
ECO mode setting
Allows power consumption to be reduced by
dimming the display or turning it off.
Setting check code
Allows the setting details to be checked via
codes.
Setting copy mode
Allows the setting details for the master sensor
to be copied to slave sensors.
Reset setting
Resets the settings to the factory settings.
NC
Hysteresis
Analog voltage
P-1, Lo-1
output
Red
when ON
Autoreference Hi-1
NO
Hysteresis
5th digit
Response time
2.5 ms
5 ms
10 ms
25 ms
50 ms
100 ms
250 ms
500 ms
1,000 ms
5,000 ms
6th digit
Unit switching
MPa
kPa
kgf/cm2
bar
psi
mmHg
inchHg
Comparative
output 2
Comparative
Always output 1
red
Comparative
output 2
Comparative
Always output 1
green Comparative
output 2
8th digit
ECO mode
OFF
STD
FULL
7th digit
Display reflesh rate
250 ms
500 ms
1,000 ms
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
Sensor
30
1.181
42.5
1.673
25.5
1.004
20
0.787
7.5 9.5
0.295 0.374
20
0.787
30
1.181
R (PT) 1/ 8
male thread
(North American: NPT 1/ 8)
1.5
0.059
Connector
12
0.472
M5 female thread
M3 female thread, 4 0.157 deep
European
European
10
7
0.394 0.276
14
0.551
G 1/ 8
male thread
13
Comparative
output 1
Remote
Comparative
P-2, Lo-2
zero-adjustment
output 1
Green
when ON Comparative
Hi-2
output 2
NO
NC
ADJ.
Window
comparator
NC
NO
Window
comparator
NC
NC
Code
Hysteresis fix value
switching
DP-10
OFF
NO
NO
Changes the display refresh rate for the
pressure value displayed in the main display.
DIMENSIONS (Unit: mm in)
OFF
EASY
Description
4th digit
Standard
type only
Multi-function 3rd digit
type
Comparative output 1 NO / NC Comparative output 2 NO / NC Analog voltage output / Threshold Display color for Display
output mode
switching output mode
switching External input
value display main display color linking
NO
Setting item
Standard type
DP-100
DIMENSIONS (Unit: mm in)
MS-DP1-1
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
Sensor mounting bracket (Optional)
Assembly dimensions
"2.3
"0.091
9.5
14.5
0.571 0.374
4.2
0.165
t2
t 0.079
20
0.787
2-R2.1 R0.083
9.5
0.374
14.5
0.571
1
0.039
4.2
0.165
2-R2.1 R0.083
22
0.866
25.5
1.004
42.5
1.673
30
1.181
20
0.787
13
0.512
R13
20
0.787 R0.512
22
0.866
2-"3.5 "0.138
9.5
0.374
7.5
0.295
45
1.772
(
30
1.181 45
1.772
)
5.3
0.209
44
5.5
1.732
0.217
12
0.472
30
1.181
15
0.591
1.5
0.059
t2
t 0.079
30
1.181
MS-DP1-2
MS-DP1-3
Panel mounting bracket (Optional), Front protection cover (Optional)
Assembly dimensions
Panel cut-out dimensions
When 1 unit is installed
0
310.4
0
1.220 0.016
0
310.4
0
1.220 0.016
39.3
1.547
34.5
1.358
7.2
0.283
11
0.433
18.3 7.5
0.720 0.295
9.5
0.374
When ‘n’ units are installed horizontally in series When ‘n’ units are installed vertically in series
0
310.4
0
1.220 0.016
31 1.220 n 3.5 0.138 (n-1)
34.5
20
1.358 0.787
0
310.4
0
1.220 0.016
50
1.969
33.4
1.315
8.7
0.343
31 1.220 n 3.5 0.138 (n-1)
55 2.165
or more
Panel thickness dimensions
1 to 6 mm 0.039 to 0.236 in
55 2.165
or more
24
33.4
1.315 0.945
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
CN-14A-C Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
L
(
35
1.378
)
50
(1.969
)
( )
8
0.315
(0.3158 )
"3.7 "0.146 cable
Model No.
Cable length (mm, in)
CN-14A-C1
1,000 39.370
CN-14A-C2
2,000 78.740
CN-14A-C3
3,000 118.110
CN-14A-C5
5,000 196.850
14
Compact Size • 2-color Digital Display
DP4 SERIES
New shape makes it most suitable for panel installation
Light-weight, compact
design
Bright, easy to view twocolor digital display
A
compact
form
specifically designed
for mounting on an
equipment panel.
It only uses half the
space of our conventional product and
provides the lightest
weight of just 30 g
(cable excluded).
The digital display is a large, easy-to-view,
and two-color digital display. It is also
functions as an output indicator as it
changes from green to red color when the
output turns ON, enabling you confirm the
output status at a glance.
40mm
60mm
Supplied with a simple-tomount panel mounting bracket
A panel mounting bracket (MS-DP-1) is
enclosed to enable simple mounting of the
sensor onto the panel surface, thus
contributing to the total cost reduction.
Conforming to
EMC Directive
UL Recognition
Rated pressure range: DP4-50/50P 0 to 101.3 kPa
DP4-52/52P 0 to 1.000 MPa
DP4-57/57P 100.0 to 100.0 kPa
Applicable fluid: Non-corrosive gas
10
Supply voltage: 12 to 24 V DC
15 %
Output: DP4-5 NPN open-collector transistor
DP4-5P PNP open-collector transistor
Pressure port: M5 female thread
Dimensions: W40H20D49 mm
Head-separated Type • 2-color Digital Display
DP5 SERIES
Controller
DPH SERIES
Sensor head
1/1,000 second high-speed response!
Response time 1 ms
Mounting the detachable head close to the
detecting section minimizes piping and
enables response time of 1 ms, as well as
greatly decreasing tact time delay. In
addition, the ultra-small and light-weight
design of the head means it can easily be
mounted on moving sections.
Sensor head with operation
indicator
The sensor head is also equipped with
operation indicator. Output
ON / OFF can be checked
on the sensor head, so
that it is suitable for
checking operation at the
suction head.
Independent use of sensor
head possible
Light-weight, compact
design
The controller inherits its lightweight,
compact design from the popular DP4
series of digital pressure sensors. Control
panel setup is low cost and requires
minimal space.
Convenient intermediate
cable with connector
Intermediate cable with connectors for
connecting the sensor head and the
controller makes operation and
maintenance easier.
Note: An intermediate cable is required to connect
the controller and the sensor head. Please
order the intermediate cable with connector
separately.
Conforming to
EMC Directive
UL Recognition
Pressure sensor heads
Rated pressure range: DPH-A0 0 to 101.3 kPa
DPH-A2 0 to 1.000 MPa
DPH-A7 100.0 to 100.0 kPa
Applicable fluid: Non-corrosive gas
10
Supply voltage: 12 to 24 V DC
15 %
Analog voltage output: 1 to 5 V
(over rated pressure range)
Pressure port: DPH-A0 M5 male thread,
DPH-A1 R (PT) 1/8 male thread / M5 female thread
DPH-A2 NPT 1/8 male thread / 10-32UNF female thread
DPH-A30 10-32UNF male thread
Dimensions: DPH-A0/A30 12.52520 mm
DPH-A1/A2 12.52525 mm
Pressure sensor controllers
Applicable pressure sensor head: DPH-A
Rated pressure range: Vacuum pressure 0 to 101.3 kPa
Positive pressure 0 to 1.000 MPa
Compound pressure 100.0 to 100.0 kPa
10
Supply voltage: 12 to 24V DC
15 %
Comparative Output (Comparative output 1, Comparative output 2):
DP5-C NPN open-collector transistor
DP5-C-P PNP open-collector transistor
Analog voltage output: 1 to 5 V DC (over rated pressure range)
Dimensions: W40H20D43 mm
All information is subject to change without prior notice.