767
FIBER
SENSORS
Head-separated Dual Display Digital Pressure Sensor
For Gas
DPS-400 SERIES DPH-100 SERIES
Related Information
■■General terms and conditions.............. F-7
■■Glossary of terms......................... P.1469~
■■Sensor selection guide.................. P.731~
■■General precautions....................... P.1472
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
panasonic.net/id/pidsx/global
Digital
Thin body controller can do cascade connection and
communication with upper devices
Works like a fiber sensor
DPS-400 series accommodates to the requirements for pressure sensors at production site such as miniaturization of
sensors for downsizing equipment, convenient shape to fit into machines, and reduction of man-hours when it comes
to replacement.
MACHINE VISION
SYSTEMS
Sensor head DPH-100 series
Controller DPS-400 series
UV CURING
SYSTEMS
Direct installation using a
hexagonal wrench
Thin body (t10 mm t0.394
in) and multi-unit connection
on a DIN rail helps to
downsize equipment for better
construction.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
● Direct mounting from above
● Installation in narrow spaces
● Extended freedom of layout
● Single axis type free turning
structure
Install on a DIN rail
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
Current value and threshold value can be checked simultaneously on the dual display
The controller is equipped with a 4-digit dual digital display. Because the threshold value can be adjusted while
checking the “current value (current pressure value)”, direct setting and checking of the “threshold value” is made
smoothly without having to switch screen modes.
Dual display + Direct setting
Because direct
setting is possible
Operation
is as easy
as analog
Thickness
10 mm 0.394 in
Threshold value Current value
“The current value” and “the threshold value” can be checked simultaneously!
Head-separated Dual Display Digital Pressure Sensor
DPS-400 SERIES DPH-100 SERIES
Wire-saving, space-saving
FIBER
SENSORS
The quick-connection cables enable reductions in wiring. The connections and man-hours for the relay terminal block
setup can be reduced and valuable space is saved. Also, DPS-400 series can be connected side-by-side with fiber
sensors FX-300 series or laser sensors LS-400 series.
Wire-saving in power supply
DPS-400 series
Fiber sensor
FX-300 series
768
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
DPS-400 series
Up to 16 sensors allowed in optical communication / setting copying
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
Power
supply cable
Wire-saving in power supply*
DPS-400, FX-300, LS-400, etc.
SIMPLE
WIRE-SAVING
UNITS
Up to 16 sensors can be connected togetther
WIRE-SAVING
SYSTEMS
Output line 1 Output line 2
Output line 2’
Output line 3
Main cable CN-74-C□
Output line 16
Output line 3’
MEASUREMENT
SENSORS
Output line 16’
Sub cable CN-72-C□
Only output lines are used, so that wiring can be greatly reduced and space saving can be obtained.
* Check the instruction manual of each model for the arrangement order and such when
connecting, as communication varies depending on the model.
Optical communication / setting copying
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
Network communication
Ultra high-speed response time at 150 μs
Connection to CC-Link open network is possible
through the communication unit for CC-Link SC-GU2-C.
Monitoring or setting changes can be carried out via a
PLC, PC, etc.
Ultra high-speed response time contributes to even
greater productivity.
Object A
Response time at 150 μs
Object B Object C
Threshold value Current pressure value
Independent dual outputs and five output modes equipped
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
The sensor is equipped with two independent
comparative outputs in which separate sensing modes
can be selected.
EASY mode
This mode is used for comparative output ON / OFF control.
Configure sensor settings to each object
through communications
by remote commands
Hysteresis mode
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
This mode is used for setting comparative output hysteresis
to the desired level and for carrying out ON / OFF control.
Flow
Window comparator mode
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
This mode is used for setting comparative output ON or OFF
at pressures within the setting range.
Forced output ON mode
The comparative outputs are forcibly maintained at ON
irrespective of the set values.
Forced output OFF mode
The comparative outputs are forcibly maintained at OFF
irrespective of the set values.
769
FIBER
SENSORS
LASER
SENSORS
Head-separated Dual Display Digital Pressure Sensor
DPS-400 SERIES DPH-100 SERIES
Hexagonal wrench installation saves man-hours and spaces
Using a hexagonal wrench, obstructions can be avoided and installation can be done easily by turning the bolt from
above.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Previous problem
Spanner is difficult to hold!
AREA
SENSORS
(Obstructed by floor surface)
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
DPH-100
Turns minimally
from above!
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Previous problem
WIRE-SAVING
SYSTEMS
Previous problem
MEASUREMENT
SENSORS
Obstac
le
Large space
needed to turn
the spanner!
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
Spanner cannot
be turned!
PLC
HUMAN MACHINE
INTERFACES
Quick maintenance
Mounting shape at 14 mm 0.551 in
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
During maintenance, the sensor head needed to be
removed can be easily removed from directly above.
Because the dead zone caused by the nut is eliminated,
the narrowed-down thickness after installation
contributes to space saving.
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
DPH-100
Remove and install the required sensor head
directly.
Previous models
14 mm 0.551 in
Wasted
space
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
DPH-10□-M3
DPH-10□-M5
Saved space
12.5 mm
0.492 in
75 mm
2.953 in
Previous models
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
DPH-100
10 mm
0.394 in
60 mm
2.362 in
20 % DOWN
from previous
models
Head-separated Dual Display Digital Pressure Sensor
DPS-400 SERIES DPH-100 SERIES
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
Controllers
Model No.
Applicable
sensor head
For compound pressure /
vacuum pressure
DPS-401
DPH-101□
DPH-103□
For positive
pressure
DPS-402
DPH-102□
Type
Appearance
Quick-connection cables
Type
Connection
method
Output
NPN open-collector
transistor two outputs
Use optional
quick-connection cable
(4-core)
Appearance
Model No.
CN-74-C1
CN-74-C2
CN-74-C5
CN-72-C1
CN-72-C2
CN-72-C5
Sub cable
(2-core)
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
Appearance
0.2 mm2 4-core cabtyre cable,
with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
0.2 mm2 2-core cabtyre cable,
with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
Model No.
Description
MS-DIN-E
When cascading multiple controllers, or when it moves depending on the way it is
installed on a DIN rail, these end plates clamp controllers into place on both sides. Make
sure to use end plates when cascading multiple controllers together.
Appearance
Rated pressure
range
DPH-10□-M3(-R)
–100.0 kPa to
+100.0 kPa
DPH-10□-M5(-R)
Positive pressure
0 to +1.000 MPa
Flexible cable type
Vacuum pressure
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
Type
Flexible
cable type
PARTICULAR
USE
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
Sensor heads
Compound
pressure
AREA
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
End plates are not supplied with the controller. Please order them separately when the controllers are mounted in cascade.
End plates
MICRO
PHOTOELECTRIC
SENSORS
PRESSURE /
FLOW
SENSORS
Description
Length: 1 m 3.281 ft
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
Quick-connection cable is not supplied with the controller. Please order it separately.
Main cable
(4-core)
DPH-10□(-R)
0 to –101.0 kPa
Flexible
cable type
Model No.
Applicable
fluid
Pressure port
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
DPH-101
R1/8 male thread + M5 female thread
DPH-101-M3
M3 male thread
DPH-101-M5
M5 male thread
DPH-101-R
R1/8 male thread + M5 female thread
DPH-101-M3-R
M3 male thread
DPH-101-M5-R
M5 male thread
DPH-102
R1/8 male thread + M5 female thread
DPH-102-M5
M5 male thread
DPH-102-M5-R
M5 male thread
DPH-103
R1/8 male thread + M5 female thread
DPH-103-M3
M3 male thread
DPH-103-M5
M5 male thread
DPH-103-R
R1/8 male thread + M5 female thread
Pressure/
Head-separated
DPH-103-M3-R
M3 male thread
Flow
DPH-103-M5-R
M5 male thread
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Air,
non-corrosive gas
Selection
Guide
Pressure/
Digital Display
5 m 16.404 ft cable length type
5 m 16.404 ft cable length type (standard: 2 m 6.562 ft) is also available. When ordering this type, suffix“-C5” to the Model No.
(e.g.) 5 m 16.404 ft cable length type of DPH-103-M5-R is “DPH-103-M5-R-C5”
OPTIONS
Designation
Model No.
Controller mounting bracket
MS-DIN-2
Mounting bracket for controller
FX-MB1
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
controller, as well as, prevents effect on another controller.
Connector seal:
It prevents contact of any metal, etc., with the pins of the
quick-connection cable.
Controller
protection seal
770
Description
Controller mounting Controller
bracket
protection seal
• MS-DIN-2
• FX-MB1
Communication
window seal
Connector seal
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
771
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Head-separated Dual Display Digital Pressure Sensor
SPECIFICATIONS
Controllers
Type
For compound pressure / vacuum pressure
For positive pressure
DPS-401
DPS-402
Compound pressure : DPH-101□
Vacuum pressure : DPH-103□
Positive pressure : DPH-102□
Rated pressure range
Compound pressure: –100.0 to +100.0 kPa
Vacuum pressure: 0 to –101.0 kPa
Positive pressure: 0 to +1.000 MPa
Display / set pressure range
Compound pressure: –199.9 to +199.9 kPa
Vacuum pressure: +101.3 to –101.3 kPa
Positive pressure: –1.050 to +1.050 MPa
Item
Model No.
Applicable sensor head
Supply voltage
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption
(Note 2)
Normal operation: 650 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
ECO mode: 500 mW or less (Current consumption 20 mA or less at 24 V supply voltage)
Sensor head supply voltage
Input voltage range: 1 to 5 V DC (over rated pressure range)
Comparative outputs
(Comparative output 1, 2)
NO / NC, selectable by jog switch
Hysteresis
Minimum 0 digit, variable by hysteresis setting
Repeatability
With compound pressure type connected: within ±0.2 % F.S. (±4 digits), With vacuum / positive pressure type connected: within ±0.2 % F.S. (±2 digits)
Response time
150 μs, 500 μs, 1 ms, 5 ms, 10 ms, 50 ms, 100 ms, 500 ms, selectable by jog switch
LASER
MARKERS
Temperature characteristics
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
NPN open-collector transistor
• Maximum sink current: 50 mA (Note 3)
• Applied voltage: 30 V DC or less (between comparative output and 0 V)
• Residual voltage: 1.5 V or less (Note 4) [at 50 mA (Note 3) sink current]
Output operation
Ambient temperature
HUMAN
MACHINE
INTERFACES
Same as supply voltage
Sensor head input
STATIC
ELECTRICITY
PREVENTION
DEVICES
PLC
–10 to +50 °C +14 to +122 °F (cascading 8 to 16 controllers: –10 to +45 °C +14 to +133 °F) (No dew condensation or icing allowed), Storage: –20 to +70 °C – 4 to +158 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Over ambient temperature range –10 to +50 °C +14 to +122 °F: within ±0.5 % F.S. of pressure at +25 °C +77 °F
Material
Enclosure: Heat-resistant ABS, Protective cover: Polycarbonate, Jog switch: ABS, MODE key: Acrylic
Weight
Net weight: 20 g approx.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Excluding current consumption of the applicable pressure sensor head.
3) 25 mA max. if 5 or more controllers are connected together.
4) In case of using the quick-connection cable (cable length: 5 m 16.404 ft)(optional)
5) The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below.
Main cable (4-core): CN-74-C1 (cable length: 1m 3.281 ft), CN-74-C2 (cable length: 2 m 6.562 ft), CN-74-C5 (cable length: 5 m 16.404 ft)
Sub cable (2-core): CN-72-C1 (cable length: 1m 3.281 ft), CN-72-C2 (cable length: 2 m 6.562 ft), CN-72-C5 (cable length: 5 m 16.404 ft)
6) The values specified above are applied only to the controller.
Sensor heads
Type
Item
Compound pressure
Positive pressure
Vacuum pressure
±100 kPa type
1 MPa type
–101 kPa type
Model No. (Note 3) DPH-101(-R) DPH-101-M3(-R) DPH-101-M5(-R)
Type of pressure
Selection
Guide
Rated pressure range
Pressure/
Digital Display
Pressure withstandability
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
DPS-400 SERIES DPH-100 SERIES
DPH-102
DPH-102-M5(-R) DPH-103(-R) DPH-103-M3(-R) DPH-103-M5(-R)
Gauge pressure
–100.0 to +100.0 kPa
0 to +1.000 MPa
0 to –101.0 kPa
500 kPa
1.5 MPa
500 kPa
Applicable fluid
Air, non-corrosive gas
Supply voltage
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption
15 mA or less
Ambient temperature
0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –10 to +60 °C +14 to +140 °F
Ambient humidity
Temperature characteristics
Front case: PBT, Rear case: PBT (glass fiber reinforced), Pressure port: Stainless steel (SUS303), O-ring: NBR
Pressure element: Silicon diaphragm, PPS
Material
0.2 mm2 4-core oil resistant cabtyre cable (Models with “-R” affixed to the Model No. have flexible, oil-resistant cabtyre cable)
Cable
Cable extension
Weight
Accessory
35 to 85 % RH, Storage: 35 to 85 % RH
Over ambient temperature range 0 to +50 °C +32 to +122 °F: within ±2 % F.S. of detected pressure at +25 °C +77 °F
Net weight
Gross weight
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
DPH-10□(-R): Head 10 g approx. / Cable 40 g approx., DPH-10□-M3/M5(-R): Head 6 g approx. / Cable 40 g approx.
DPH-10□(-R): 80 g approx., DPH-10□-M3/M5(-R): 70 g approx.
Connector (e-CON): 1 pc. (Note 4)
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +25 °C +77 °F.
2) The sensor head can be used independently.
3) Model No. having the suffix “-R” is flexible cable type.
4) Connectors (e-CON) are available as spare parts. CN-EP2: 5 pcs.
Head-separated Dual Display Digital Pressure Sensor
DPS-400 SERIES DPH-100 SERIES
772
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram
ZD3
Analog
voltage
input
0V
+V
(Brown) +V (Note1)
D1
(Black)
Comparative output 1
(White)
Comparative output 2
ZD1
Load
Load
50 mA max.(Note2)
MICRO
PHOTOELECTRIC
SENSORS
+V
Color code of connector attached cable
Comparative
output 1
12 to 24 V DC
±10 %
Terminal No.
Comparative output 2
0V
Analog voltage
input AREA
SENSORS
Model LIGHT
CURTAINS /
discrimination
SAFETY signal
0V
ZD2 (Blue) 0 V (Note1) 50 mA max.(Note2)
Sensor head
Controller internal circuit
internal circuit Intermediate cable
COMPONENTS
PRESSURE /
FLOW
SENSORS
Users’ circuit
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 25 mA max. if 5 or more controllers are connected together.
3) Do not use the controllers in a series (AND) connection.
+V
Symbols …
PHOTOELECTRIC
SENSORS
Terminal No.
Controller main circuit
Sensor head main circuit
1 kΩ
+V
Model
discrimination
signal
LASER
SENSORS
Quick-connection cable side terminal
arrangement diagram
Terminal No.
D2
FIBER
SENSORS
D1, D2 : Reverse supply polarity protection
ZD1 to ZD3 : Surge absorption zener diode
diodeComparative
output 1
0V
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
• The DPH-100 series is designed for use
with air and non-corrosive gas. It cannot
be used with liquid or corrosive and
inflammable gases.
Wiring
• Make sure to use the optional quick-connection cable for
the connection of the controller. Extension up to total 50 m
164.042 ft (cascading 9 to 16 controllers: 20 m 65.617 ft) is
possible with 0.3 mm2, or more, cable. However, in order to
reduce noise, make the wiring as short as possible.
Sensor head side terminal arrangement
diagram
PARTICULAR
USE
SENSORS
+V
Terminal No.
Comparative output 2
0V
INDUCTIVE
PROXIMITY
SENSORS
Analog voltage
input
Model
discrimination signal
Refer to p.1472 for general precautions.
Others
• This product has been developed / produced for
industrial use only.
• Use within the rated pressure range.
• Do not use during the initial transient time (controller: 1 sec. approx.,
sensor head: 50 ms approx.) after the power supply is switched on.
• Do not apply pressure exceeding the pressure
withstandability value. The diaphragm will get damaged
and correct operation shall not be maintained.
• Do not insert wires, etc., into the pressure port.
The diaphragm will get damaged and correct operation
shall not be maintained.
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
773
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Head-separated Dual Display Digital Pressure Sensor
DIMENSIONS (Unit: mm in)
Select 2 indicator (Yellow)
Select 1 indicator (Yellow)
Comparative output 1
operation indicator (Orange)
Comparative output 2
operation indicator (Orange)
PRESSURE /
FLOW
SENSORS
10
0.394
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
11
0.433
MS-DIN-E
Controller
12
0.472
58.7
30.85 2.311
1.215
2.7
8.4
0.106
0.331
End plate (Optional)
2.75
0.108
M3 (length 18 mm 0.709 in) pan head screws
MODE key
Decimal point
mark (Note1)
75
2.953
Communication window
3
0.118
Jog switch
Digital display (Green / Red)
3
0.118
INDUCTIVE
PROXIMITY
SENSORS
SENSOR
OPTIONS
The CAD data in the dimensions can be downloaded from our website.
DPS-401 DPS-402
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PARTICULAR
USE
SENSORS
DPS-400 SERIES DPH-100 SERIES
1.6
0.063
32
1.260
4
0.157
Suitable for 35 mm 1.378 in width DIN rail
Material: Polycarbonate
36.5
1.437
3.95
0.156
Note: D
ecimal points for pressure value. Above figure shows the DPS-401
(compound pressure / vacuum pressure). Positions of display and the
pressure unit on the name plate for DPS-402 (positive pressure) differ
from the above figure.
CN-74-C1 CN-74-C2 CN-74-C5
Model No.
Length L
1,000 39.370
CN-74-C2
2,000 78.740
HUMAN
MACHINE
INTERFACES
CN-74-C5
5,000 196.850
ø3.3 ø0.130 cable
( )
14
0.551
2.9
(0.114
)
2.54
0.100
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
10
0.394
6
0.236
( )
MACHINE
VISION
SYSTEMS
2.54
0.100
2.65
0.104
Length L
CN-72-C1
1,000 39.370
CN-72-C2
2,000 78.740
CN-72-C5
5,000 196.850
2.54
0.100
7
0.276
10
0.394
13.6
0.535
DPH-10□(-R)
3
0.118
7.2
0.283
Sensor head
2.65
0.104
2.54
0.100
0.2
0.008
4.8
0.189
23.4
0.921
6.6
0.260
ø8.3
ø0.327
5
0.197
ø6.2
ø0.244
10
0.394
7
0.276
10
0.394
13.6
0.535
3
0.118
7.2
0.283
Sensor head
4.8
0.189
ø8.4
ø0.331
5
0.197
ø3.7 ø0.146 cable,
(2 m 6.562 ft / 5 m 16.404 ft long)
7.8
0.307
Gasket
A
R 1/ 8
20.5
0.807
14 0.5
0.551 0.020
7
0.276
14 10
0.5510.394
9
0.354
M5 female thread
( )
Hexagonal hole
(bolt width 3 0.118, 3.5 0.138 deep)
Hexagonal hole
(bolt width 5 0.197, 4 0.157 deep)
Pressure/
Digital Display
13.2
0.520
2.9
(0.114
)
10
0.394
6
0.236
R5
R0.197
Selection
Guide
Flow
14
(0.551
)
DPH-10□-M3(-R) DPH-10□-M5(-R)
R6.6
R0.260
Pressure/
Head-separated
ø3.3 ø0.130 cable
3
0.118
12 10.5
(0.472
)0.413
0.2
0.008
UV
CURING
SYSTEMS
50
1.969
L
Model No.
12
10.5
(0.472
) 0.413
FA
COMPONENTS
Sub cable (Optional)
• Length L
50
1.969
L
CN-74-C1
CN-72-C1 CN-72-C2 CN-72-C5
Main cable (Optional)
• Length L
PLC
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
5.6 M3 square nut
0.220
24.7
0.972
10.5
0.413
24
3
0.945
0.118
Suitable for 35 mm 1.378 in width DIN rail
3
0.118
3
0.118
7
0.276
27.8
1.094
30
1.181
15
0.591
60
2.362
Model No.
A
DPH-10□-M3(-R)
3.5 0.118
DPH-10□-M5(-R)
3.5 0.138
6.6
0.260
ø3.7 ø0.146 cable,
2 m 6.562 ft long
DPH-10□-M3(-R): M3 male thread
DPH-10□-M5(-R): M5 male thread
Head-separated Dual Display Digital Pressure Sensor
DIMENSIONS (Unit: mm in)
MS-DIN-2
The CAD data in the dimensions can be downloaded from our website.
Controller mounting bracket (Optional)
21.6
0.850
16
0.630
0.4
0.016
3.2
0.126
10
ø1.8
ø0.071
5.2
0.205
2-ø3.2 ø0.126 holes
5 0.394
0.197
35
1.378
2
0.079
2
0.079
7.5
4.2
0.295 0.165
774
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
8.5 5.2
0.335 0.205
3.2
0.126
DPS-400 SERIES DPH-100 SERIES
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
t1
t 0.039
27
1.063
Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100