0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DPS-401

DPS-401

  • 厂商:

    NAIS(松下)

  • 封装:

    Modular

  • 描述:

    SENSOR POSITIVE PRESSURE

  • 数据手册
  • 价格&库存
DPS-401 数据手册
699 FIBER SENSORS Head-separated Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES DPH-100 SERIES Related Information ■■General terms and conditions............ F-17 ■■Glossary of terms......................... P.1373~ ■■Sensor selection guide.................. P.661~ ■■General precautions....................... P.1405 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated panasonic-electric-works.net/sunx Digital Thin body controller can do cascade connection and communication with upper devices Works like a fiber sensor DPS-400 series accommodates to the requirements for pressure sensors at production site such as miniaturization of sensors for downsizing equipment, convenient shape to fit into machines, and reduction of man-hours when it comes to replacement. Sensor head DPH-100 series Controller DPS-400 series Direct installation using a hexagonal wrench Thin body (t10 mm t0.394 in) and multi-unit connection on a DIN rail helps to downsize equipment for better construction. ● Direct mounting from above ● Installation in narrow spaces ● Extended freedom of layout ● Single axis type free turning structure Install on a DIN rail Flow Other Products DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DP5/DPH Current value and threshold value can be checked simultaneously on the dual display The controller is equipped with a 4-digit dual digital display. Because the threshold value can be adjusted while checking the “current value (current pressure value)”, direct setting and checking of the “threshold value” is made smoothly without having to switch screen modes. Dual display + Direct setting Because direct setting is possible Operation is as easy as analog Thickness 10 mm 0.394 in Threshold value Current value “The current value” and “the threshold value” can be checked simultaneously! Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES Wire-saving, space-saving FIBER SENSORS The quick-connection cables enable reductions in wiring. The connections and man-hours for the relay terminal block setup can be reduced and valuable space is saved. Also, DPS-400 series can be connected side-by-side with fiber sensors FX-300 series or laser sensors LS series. Wire-saving in power supply DPS-400 series Fiber sensor FX-300 series 700 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS DPS-400 series LIGHT CURTAINS Up to 16 sensors allowed in optical communication / setting copying PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Power supply cable Wire-saving in power supply* DPS-400, FX-300, LS-400, etc. SIMPLE WIRE-SAVING UNITS Up to 16 sensors can be connected togetther WIRE-SAVING SYSTEMS Output line 1 Output line 2 Output line 2’ Output line 3 Main cable CN-74-C□ Output line 16 Output line 3’ MEASUREMENT SENSORS Output line 16’ Sub cable CN-72-C□ Only output lines are used, so that wiring can be greatly reduced and space saving can be obtained. * Check the instruction manual of each model for the arrangement order and such when connecting, as communication varies depending on the model. Optical communication / setting copying STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS Network communication Ultra high-speed response time at 150 μs PLC / TERMINALS Connection to CC-Link open network is possible through the communication unit for CC-Link SC-GU2-C. Monitoring or setting changes can be carried out via a PLC, PC, etc. Ultra high-speed response time contributes to even greater productivity. HUMAN MACHINE INTERFACES Object A Response time at 150 μs Object B Object C Threshold value Current pressure value Independent dual outputs and five output modes equipped The sensor is equipped with two independent comparative outputs in which separate sensing modes can be selected. EASY mode This mode is used for comparative output ON / OFF control. Configure sensor settings to each object through communications by remote commands Hysteresis mode This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON / OFF control. Window comparator mode This mode is used for setting comparative output ON or OFF at pressures within the setting range. Forced output ON mode The comparative outputs are forcibly maintained at ON irrespective of the set values. Forced output OFF mode The comparative outputs are forcibly maintained at OFF irrespective of the set values. ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow Other Products DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DP5/DPH 701 FIBER SENSORS LASER SENSORS Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES Hexagonal wrench installation saves man-hours and spaces Using a hexagonal wrench, obstructions can be avoided and installation can be done easily by turning the bolt from above. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Previous problem Spanner is difficult to hold! AREA SENSORS (Obstructed by floor surface) LIGHT CURTAINS DPH-100 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Turns minimally from above! PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Previous problem WIRE-SAVING SYSTEMS Previous problem MEASUREMENT SENSORS Obstac le Large space needed to turn the spanner! STATIC CONTROL DEVICES ENDOSCOPE Spanner cannot be turned! LASER MARKERS PLC / TERMINALS Quick maintenance Mounting shape at 14 mm 0.551 in HUMAN MACHINE INTERFACES During maintenance, the sensor head needed to be removed can be easily removed from directly above. Because the dead zone caused by the nut is eliminated, the narrowed-down thickness after installation contributes to space saving. ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated DPH-100 Remove and install the required sensor head directly. Previous models DPH-10□-M3 DPH-10□-M5 Saved space 14 mm 0.551 in Wasted space 12.5 mm 0.492 in 75 mm 2.953 in Previous models Flow Other Products DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DP5/DPH DPH-100 10 mm 0.394 in 60 mm 2.362 in 20 % DOWN from previous models Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES ORDER GUIDE FIBER SENSORS LASER SENSORS Controllers Model No. Applicable sensor head For compound pressure / vacuum pressure DPS-401 DPH-101□ DPH-103□ For positive pressure DPS-402 DPH-102□ Type Appearance Connection method Output NPN open-collector transistor two outputs Use optional quick-connection cable (4-core) PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS Quick-connection cables Type Quick-connection cable is not supplied with the controller. Please order it separately. Appearance Model No. CN-74-C1 CN-74-C2 CN-74-C5 CN-72-C1 CN-72-C2 CN-72-C5 Main cable (4-core) Sub cable (2-core) PRESSURE / FLOW SENSORS Description Length: 1 m 3.281 ft Length: 2 m 6.562 ft Length: 5 m 16.404 ft Length: 1 m 3.281 ft Length: 2 m 6.562 ft Length: 5 m 16.404 ft INDUCTIVE PROXIMITY SENSORS 0.15 mm2 4-core cabtyre cable, with connector on one end Cable outer diameter: ø3.0 mm ø0.118 in 0.15 mm2 2-core cabtyre cable, with connector on one end Cable outer diameter: ø3.0 mm ø0.118 in End plates are not supplied with the controller. Please order them separately when the controllers are mounted in cascade. End plates Appearance Model No. Description MS-DIN-E When cascading multiple controllers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp controllers into place on both sides. Make sure to use end plates when cascading multiple controllers together. Flexible cable type Appearance Rated pressure range DPH-10□-M3(-R) –100.0 kPa to +100.0 kPa DPH-10□-M5(-R) Positive pressure 0 to +1.000 MPa Flexible cable type Vacuum pressure SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS ENDOSCOPE LASER MARKERS PLC / TERMINALS Type Compound pressure PARTICULAR USE SENSORS STATIC CONTROL DEVICES Sensor heads DPH-10□(-R) 0 to –101.0 kPa Flexible cable type Model No. Applicable fluid Pressure port HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS DPH-101 R1/8 male thread + M5 female thread DPH-101-M3 M3 male thread DPH-101-M5 M5 male thread DPH-101-R R1/8 male thread + M5 female thread DPH-101-M3-R M3 male thread DPH-101-M5-R M5 male thread DPH-102 R1/8 male thread + M5 female thread DPH-102-M5 M5 male thread DPH-102-M5-R M5 male thread DPH-103 R1/8 male thread + M5 female thread DPH-103-M3 M3 male thread DPH-103-M5 M5 male thread DPH-103-R R1/8 male thread + M5 female thread Pressure/ Head-separated DPH-103-M3-R M3 male thread Flow DPH-103-M5-R M5 male thread Other Products FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Air, non-corrosive gas Selection Guide Pressure/ Digital Display 5 m 16.404 ft cable length type 5 m 16.404 ft cable length type (standard: 2 m 6.562 ft) is also available. When ordering this type, suffix“-C5” to the Model No. (e.g.) 5 m 16.404 ft cable length type of DPH-103-M5-R is “DPH-103-M5-R-C5” OPTIONS Designation Model No. Controller mounting bracket MS-DIN-2 Mounting bracket for controller FX-MB1 10 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another controller, as well as, prevents effect on another controller. Connector seal: It prevents contact of any metal, etc., with the pins of the quick-connection cable. Controller protection seal 702 Description Controller mounting Controller bracket protection seal • MS-DIN-2 • FX-MB1 Communication window seal Connector seal DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DP5/ DPH 703 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Head-separated Dual Display Digital Pressure Sensor SPECIFICATIONS Controllers Type For compound pressure / vacuum pressure For positive pressure DPS-401 DPS-402 Compound pressure : DPH-101□ Vacuum pressure : DPH-103□ Positive pressure : DPH-102□ Rated pressure range Compound pressure: –100.0 to +100.0 kPa Vacuum pressure: 0 to –101.0 kPa Positive pressure: 0 to +1.000 MPa Display / set pressure range Compound pressure: –199.9 to +199.9 kPa Vacuum pressure: +101.3 to –101.3 kPa Positive pressure: –1.050 to +1.050 MPa Item Model No. Applicable sensor head Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less Power consumption (Note 2) Normal operation: 650 mW or less (Current consumption 25 mA or less at 24 V supply voltage) ECO mode: 500 mW or less (Current consumption 20 mA or less at 24 V supply voltage) Sensor head supply voltage Input voltage range: 1 to 5 V DC (over rated pressure range) Comparative outputs (Comparative output 1, 2) MEASUREMENT SENSORS Response time NO / NC, selectable by jog switch Minimum 0 digit, variable by hysteresis setting With compound pressure type connected: within ±0.2 % F.S. (±4 digits), With vacuum / positive pressure type connected: within ±0.2 % F.S. (±2 digits) Repeatability 150 μs, 500 μs, 1 ms, 5 ms, 10 ms, 50 ms, 100 ms, 500 ms, selectable by jog switch STATIC CONTROL DEVICES Ambient temperature ENDOSCOPE Temperature characteristics HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS NPN open-collector transistor • Maximum sink current: 50 mA (Note 3) • Applied voltage: 30 V DC or less (between comparative output and 0 V) • Residual voltage: 1.5 V or less (Note 4) [at 50 mA (Note 3) sink current] Output operation Hysteresis PLC / TERMINALS Same as supply voltage Sensor head input WIRE-SAVING SYSTEMS LASER MARKERS –10 to +50 °C +14 to +122 °F (cascading 8 to 16 controllers: –10 to +45 °C +14 to +133 °F) (No dew condensation or icing allowed), Storage: –20 to +70 °C – 4 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Over ambient temperature range –10 to +50 °C +14 to +122 °F: within ±0.5 % F.S. of pressure at +25 °C +77 °F Material Enclosure: Heat-resistant ABS, Protective cover: Polycarbonate, Jog switch: ABS, MODE key: Acrylic Weight 20 g approx. (main body only) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Excluding current consumption of the applicable pressure sensor head. 3) 25 mA max. if 5 or more controllers are connected together. 4) In case of using the quick-connection cable (cable length: 5 m 16.404 ft)(optional) 5) The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below. Main cable (4-core): CN-74-C1 (cable length: 1m 3.281 ft), CN-74-C2 (cable length: 2 m 6.562 ft), CN-74-C5 (cable length: 5 m 16.404 ft) Sub cable (2-core): CN-72-C1 (cable length: 1m 3.281 ft), CN-72-C2 (cable length: 2 m 6.562 ft), CN-72-C5 (cable length: 5 m 16.404 ft) 6) The values specified above are applied only to the controller. Sensor heads UV CURING SYSTEMS Type Item Compound pressure Positive pressure Vacuum pressure ±100 kPa type 1 MPa type –101 kPa type Model No. (Note 3) DPH-101(-R) DPH-101-M3(-R) DPH-101-M5(-R) Type of pressure Selection Guide Rated pressure range Pressure/ Digital Display Pressure withstandability Pressure/ Head-separated Flow Other Products DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DP5/ DPH DPS-400 SERIES DPH-100 SERIES DPH-102 DPH-102-M5(-R) DPH-103(-R) DPH-103-M3(-R) DPH-103-M5(-R) Gauge pressure –100.0 to +100.0 kPa 0 to +1.000 MPa 0 to –101.0 kPa 500 kPa 1.5 MPa 500 kPa Applicable fluid Air, non-corrosive gas Supply voltage 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Current consumption 15 mA or less Ambient temperature 0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –10 to +60 °C +14 to +140 °F Ambient humidity Temperature characteristics Front case: PBT, Rear case: PBT (glass fiber reinforced), Pressure port: Stainless steel (SUS303), O-ring: NBR Pressure element: Silicon diaphragm, PPS Material 0.2 mm2 4-core oil resistant cabtyre cable (Models with “-R” affixed to the Model No. have flexible, oil-resistant cabtyre cable) Cable Cable extension Weight Accessory 35 to 85 % RH, Storage: 35 to 85 % RH Over ambient temperature range 0 to +50 °C +32 to +122 °F: within ±2 % F.S. of detected pressure at +25 °C +77 °F Net weight Gross weight Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable. DPH-10□(-R): Head 10 g approx. / Cable 40 g approx., DPH-10□-M3/M5(-R): Head 6 g approx. / Cable 40 g approx. DPH-10□(-R): 80 g approx., DPH-10□-M3/M5(-R): 70 g approx. Connector (e-CON): 1 pc. (Note 4) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +25 °C +77 °F. 2) The sensor head can be used independently. 3) Model No. having the suffix “-R” is flexible cable type. 4) Connectors (e-CON) are available as spare parts. CN-EP2: 5 pcs. Head-separated Dual Display Digital Pressure Sensor 704 DPS-400 SERIES DPH-100 SERIES I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram ZD3 Analog voltage input 0V Terminal No. (Brown) +V (Note1) D1 (Black) Comparative output 1 (White) Comparative output 2 ZD1 ② Comparative output 1 ③ 0V Load Load 50 mA max.(Note2) 12 to 24 V DC ±10 % ZD2 (Blue) 0 V (Note1) 50 mA max.(Note2) Sensor head Controller internal circuit internal circuit Intermediate cable ① +V ① +V Color code of connector attached cable Controller main circuit Sensor head main circuit 1 kΩ +V Model discrimination signal LASER SENSORS Quick-connection cable side terminal arrangement diagram Terminal No. D2 FIBER SENSORS Terminal No. ④ Comparative output 2 ③ 0V PHOTOELECTRIC SENSORS ② MICRO PHOTOELECTRIC SENSORS Analog voltage input AREA SENSORS ④ Model LIGHT discrimination signal CURTAINS PRESSURE / FLOW SENSORS Users’ circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 25 mA max. if 5 or more controllers are connected together. 3) Do not use the controllers in a series (AND) connection. ① +V ② Symbols … D1, D2 : Reverse supply polarity protection diodeComparative D1 D3 Z to Z : Surge absorption zener diode output 1 ③ 0V PRECAUTIONS FOR PROPER USE • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • The DPH-100 series is designed for use with air and non-corrosive gas. It cannot be used with liquid or corrosive and inflammable gases. Wiring • Make sure to use the optional quick-connection cable for the connection of the controller. Extension up to total 50 m 164.042 ft (cascading 9 to 16 controllers: 20 m 65.617 ft) is possible with 0.3 mm2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. Sensor head side terminal arrangement diagram ① +V Terminal No. ④ Comparative output 2 ③ 0V INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS ② Analog voltage input ④ Model discrimination signal Refer to General precautions. Others • This product has been developed / produced for industrial use only. • Use within the rated pressure range. • Do not use during the initial transient time (controller: 1 sec. approx., sensor head: 50 ms approx.) after the power supply is switched on. • Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. • Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow Other Products DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DP5/ DPH 705 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Head-separated Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) Select 2 indicator (Yellow) Select 1 indicator (Yellow) Comparative output 1 operation indicator (Orange) Comparative output 2 operation indicator (Orange) PRESSURE / FLOW SENSORS 10 0.394 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS 11 0.433 End plate (Optional) 2.75 0.108 M3 (length 18 mm 0.709 in) pan head screws MODE key Decimal point mark (Note1) Digital display (Green / Red) 75 2.953 Communication window 3 0.118 Jog switch 3 0.118 1.6 0.063 32 1.260 4 0.157 Suitable for 35 mm 1.378 in width DIN rail Material: Polycarbonate 36.5 1.437 3.95 0.156 Note: Decimal points for pressure value. Above figure shows the DPS-401 (compound pressure / vacuum pressure). Positions of display and the pressure unit on the name plate for DPS-402 (positive pressure) differ from the above figure. CN-74-C1  CN-74-C2  CN-74-C5 Length L CN-74-C1 1,000 39.370 CN-74-C2 2,000 78.740 CN-74-C5 5,000 196.850 ø3 ø0.118 cable ( ) 14 0.551 2.9 (0.114 ) 2.54 0.100 10 0.394 6 0.236 ( ) 2.54 0.100 2.65 0.104 Length L CN-72-C1 1,000 39.370 CN-72-C2 2,000 78.740 CN-72-C5 5,000 196.850 2.54 0.100 7 0.276 10 0.394 13.6 0.535 DPH-10□(-R) 3 0.118 7.2 0.283 Sensor head 2.65 0.104 2.54 0.100 0.2 0.008 DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DP5/ DPH 4.8 0.189 23.4 0.921 6.6 0.260 ø8.3 ø0.327 5 0.197 ø6.2 ø0.244 10 0.394 7 0.276 10 0.394 13.6 0.535 3 0.118 7.2 0.283 Sensor head 4.8 0.189 ø8.4 ø0.331 5 0.197 ø3.7 ø0.146 cable, (2 m 6.562 ft / 5 m 16.404 ft long) 7.8 0.307 Gasket A R 1/ 8 20.5 0.807 14 0.5 0.551 0.020 7 0.276 14 10 0.5510.394 9 0.354 M5 female thread ( ) Hexagonal hole (bolt width 3 0.118, 3.5 0.138 deep) Hexagonal hole (bolt width 5 0.197, 4 0.157 deep) Pressure/ Digital Display 13.2 0.520 2.9 (0.114 ) 10 0.394 6 0.236 R5 R0.197 Selection Guide Flow 14 (0.551 ) DPH-10□-M3(-R)   DPH-10□-M5(-R) R6.6 R0.260 Pressure/ Head-separated ø3 ø0.118 cable 3 0.118 12 10.5 (0.472 )0.413 0.2 0.008 MACHINE VISION SYSTEMS 50 1.969 L Model No. 12 10.5 (0.472 ) 0.413 FA COMPONENTS Sub cable (Optional) • Length L 50 1.969 L Model No. CN-72-C1  CN-72-C2  CN-72-C5 Main cable (Optional) • Length L ENERGY CONSUMPTION VISUALIZATION COMPONENTS Other Products 5.6 M3 square nut 0.220 24.7 0.972 10.5 0.413 24 3 0.945 0.118 Suitable for 35 mm 1.378 in width DIN rail 15 0.591 60 2.362 3 0.118 7 0.276 27.8 1.094 30 1.181 HUMAN MACHINE INTERFACES UV CURING SYSTEMS MS-DIN-E Controller 12 0.472 58.7 30.85 2.311 1.215 2.7 8.4 0.106 0.331 3 0.118 INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS The CAD data in the dimensions can be downloaded from our website. DPS-401  DPS-402 LIGHT CURTAINS PARTICULAR USE SENSORS DPS-400 SERIES DPH-100 SERIES Model No. A DPH-10□-M3(-R) 3.5 0.118 DPH-10□-M5(-R) 3.5 0.138 6.6 0.260 ø3.7 ø0.146 cable, 2 m 6.562 ft long DPH-10□-M3(-R): M3 male thread DPH-10□-M5(-R): M5 male thread Head-separated Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) MS-DIN-2 The CAD data in the dimensions can be downloaded from our website. Controller mounting bracket (Optional) 21.6 0.850 16 0.630 0.4 0.016 3.2 0.126 10 ø1.8 ø0.071 5.2 0.205 2-ø3.2 ø0.126 holes 5 0.394 0.197 35 1.378 2 0.079 2 0.079 7.5 4.2 0.295 0.165 706 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS 8.5 5.2 0.335 0.205 3.2 0.126 DPS-400 SERIES DPH-100 SERIES MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS t1 t 0.039 27 1.063 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow Other Products DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DP5/ DPH
DPS-401 价格&库存

很抱歉,暂时无法提供与“DPS-401”相匹配的价格&库存,您可以联系我们找货

免费人工找货
DPS-401
  •  国内价格 香港价格
  • 1+1756.567701+218.58639
  • 10+1596.8806010+198.71501

库存:1