EKMC1604112

EKMC1604112

  • 厂商:

    NAIS(松下)

  • 封装:

    Module

  • 描述:

    SENSOR PIR WALL MNT 170UA BLK LE

  • 数据手册
  • 价格&库存
EKMC1604112 数据手册
motion sensor EKMC(VZ)series Current consumption 170μA Digital output ○Economy type suitable for a wide range of applications Recommended applications Standard detection type Lighting control, lighting equipment, heaters, ventilators or air conditioners, security equipment for IP cameras, intrusion alarms, digital signage, vending machines, multi-function printers, display panels for meeting rooms, PCs Long distance detection type Lensless type available Wall installation type 170μA type: EKMC1600100 Specifications Current consumption Detection performance Model no. Lens color Standard detection type EKMC1601111 White EKMC1601112 Black EKMC1601113 Pearl white EKMC1603111 Long distance detection type 170μA Black EKMC1603113 Pearl white EKMC1604111 White EKMC1604112 Black EKMC1604113 Pearl white ■ Ordering  information Detection area Detection distance Horizontal Vertical Detection zones 5m 94° 82° 64 12m 102° 92° 92 12m(1st step lens) 6m(2nd step lens) 3m(3rd step lens) 40° 105° 68 White EKMC1603112 Wall installation type Output type EKMC16 Digital 1 ●Lens color  0: Lensless / 1: White /  2: Black / 3: Pearl white ●PaPIRs motion sensor ●Detection(Lens)  00: Lensless / 01: 5m distance standard /  03: 12m long distance / 04: Wall installation type Characteristics ● Lens   0: Lensless / 1:with lens Timing chart ■ Maximum rated values ON Items Value Power supply voltage Ambient temperature Storage temperature -0.3 to 7V -20 to +60 ℃ (no frost, no condensation) -20 to +70 ℃ Power supply OFF Present Detecting target ■ Electrical characteristics Items Vdd 6.0V 3.0V Current consumption Ave (in standby mode) Note 1) Iw 170μA Output current Max (during detection) Note 2) Iout Operating voltage Max Min Output voltage Min (during detection period) Vout Circuit stability time Max Twu (when voltage is applied) 7 Absent Symbol EKMC(VZ)type 100μA Vdd‐0.5V 30 sec Conditions ー Ambient temperature: 25℃ Iout=0 Vdd: 5V Ambient temperature: 25℃ Vout≧Vdd-0.5 Ambient temperature: 25℃ Open at no detection Ambient temperature: 25℃ Iout=0 Vdd: 5V Note 1) Current consumption during detection period is the total value of current consumption in standby mode add to output current. Note 2) Please select an output resistors (pull-down concept) in accordance with Vout so that the output current is lower than or equal to 100μA. If the output current is more than 100μA, this may cause false alarms. ON Output voltage OFF Twu 【Explanation of the timing】 Twu: Circuit stability time: max. 30 sec During this stage, the output’ s status is undefined (ON/OFF) and detection is therefore not guaranteed. Lenses for the EKMB/EKMC series Dimension Detection zone (mm) Detection characteristics Y Standard detection type 5m Y Detection distance Field of view Detection zone Detection condition 2.5m φ9.5 CAD data (48.5° ) 41° A A 13 φ0.45 ±0.05 5.6m X 14.4 4.6 φ11 VDD GND 45°±4 6.6m X-Y Cross Section (48.5° )41° P.C.D.φ5. 08 ±0.2 OUT SIDE VIEW ±4 45° Max. 5m ×82 ° 94 ° 64 beams ・The temperature difference between the target and the surroundings must be higher than 4℃. ・Movement speed: 1.0m/s 47° (53° ) ・Target concept: Human 47° (53° ) body with an approx. size of 700×250mm X A-A Cross sectional ・Target moving direction: Crossing the detection beam. TOP VIEW 5m Y 12m Long distance detection type 2.5m (49.5° ) 46.3° Y CAD data Detection distance Field of view Detection zone Detection condition 5m 22 φ20.7 11.6m X 20.2 A A 7.3 φ0.45 ±0.05 P.C 4.6 φ11 .D.φ 5.0 ± 8 0 13.8m X-Y Cross Section VDD .2 2.5 GND 46.3° (49.5° ) 5 OUT 45°± 4° SIDE VIEW ° ±4 45° Max. 12m ×92 ° 102 ° 92 beams ・The temperature difference between the target and the surroundings must be higher than 4℃. ・Movement speed: 1.0m/s 51.3° (54° ) 51.3° (54° ) ・Target concept: Human body with an approx. size of 700×250mm X ・Target moving direction: Crossing the detection beam. TOP VIEW 12m A-A Cross sectional Wall installation type 5m Detection distance Y φ22 φ20.7 CAD data 5.7m 2nd step 18° 25° A 20.2 A φ0.45 ±0.05 4.6 X-Y Cross Section SIDE VIEW φ11 .D.φ 5.0 ± 8 0 3rd step 14.9m 44° 5m (49° ) 12m 7.3 P.C 1st step 4° VDD .2 2.5 GND 52.5° (56° ) 5 OUT 45°± 4° X Field of view Detection zone Detection condition 52.5° (56° ) 5m ° ±4 45° TOP VIEW 12m 1st step lens Max. 12m 2nd step lens Max. 6m 3rd step lens Max. 3m ×105 ° 40 ° 68 beams ・The temperature difference between the target and the surroundings must be higher than 4℃. ・Movement speed: 1.0m/s ・Target concept: Human body with an approx. size of 700×250mm ・Target moving direction: Crossing the detection beam. A-A Cross sectional ■ PIR element Lensless type 3.0 0.6mm 3.0 Average: 5.6μW/c ㎡ Detection sensitivity 0.4mm φ9.1 φ8.3 55° 0.6mm Maximum: 7.6μW/c ㎡ ELEMENT 9.3 8.4 ※Detection sensitivity is measured by following system 0.6mm 0.6mm 0.4mm ■ Test setup φ0.45 ±0.05 5.5 P.C .D.φ 5.08 ±0 Black body 250℃ Aperture φ3.2mm Masking plate PaPIRs VDD DC5V .2 GND OUT 45°± 4° 340mm Chopper (1Hz) ° ±4 45° CAD data CAD data can be downloaded from the PaPIRs WEB site. Panasonic PaPIRs Recorder Search Please refer to the formal specification for the dimension, and the tolerance ※Please note that the horizontal and vertical field of view depends on the position of the metal tab on which the lens is mounted. 8 SATURN LENS – NEW Dual zone 90° 90° 44° 44° Standard motion detection area 2.2m 1.8m Slight motion detection area ø4.4m Standard and slight-motion detection type Choose by the current consumption in standby mode 1μA (1μA type: in sleep mode) 2μA Choose by output 6μA Digital 170μA Digital Analog White EKMB1193111 EKMB1293111 EKMB1393111K EKMC1693111 By request Black EKMB1193112 EKMB1293112 EKMB1393112K EKMC1693112 By request Pearl white EKMB1193113 EKMB1293113 EKMB1393113K EKMC1693113 By request Choose by lens color Saturn lens Dimension Detection zone (mm) Standard and slightmotion detection type Detection characteristics Detection distance Vertical Slight motion detection area CAD data by request 14.9 14.1 17.2 7.9 A (0.018 dia) 4.6 0.45 ±0.05 11 P.C.D 5.08 ±0.2 Max. 2.2m* Slight motion Standard motion Slight motion Standard motion 2 4.5 GND OUT 45 4° °± 44° x 44° 90° x 90° 36 48 • The temperature difference between the target and the surroundings must be higher than 4°C. • Movement speed: 0.5ms • Target concept: Human head with an approx. size of 200x200mm • Target moving direction: Crossing the detection beam, 1 zone Standard motion • The temperature VDD ±4° Field of view Detection zone Detection Slight motion condition ▲ A 45° Standard motion detection area Horizontal difference between the target and the surroundings must be higher than 4°C. • Movement speed: 1.0ms • Target concept: Human body with an approx. size of 400x200mm • Target moving direction: Crossing the detection beam, 2 zones * Under specified detection conditions ▲ Please refer to “Caution for use” (page 13) and “Basic principles”(page 13, point 5), for more details Please contact your local sales representative for detailed specifications.
EKMC1604112 价格&库存

很抱歉,暂时无法提供与“EKMC1604112”相匹配的价格&库存,您可以联系我们找货

免费人工找货
EKMC1604112
  •  国内价格 香港价格
  • 1+82.254051+10.55413
  • 5+74.366975+9.54213
  • 10+71.4458710+9.16732
  • 25+67.9557025+8.71949
  • 50+65.5710150+8.41350
  • 100+63.38482100+8.13299
  • 500+58.98155500+7.56800
  • 1000+57.340461000+7.35743

库存:0

EKMC1604112

    库存:0

    EKMC1604112

      库存:0