Power Inductors
Power Inductors /
Wire Wound type
Series : G
Type : ELL6GG
ELL6PG
Features
● Magnetic
shielded structure
DC resistance and large current capability
● RoHS compliant
● Low
Recommended Applications
● DSC,
Tablet terminal, Portable game device, DC/DC converter circuit for cellular phone
Standard Packing Quantity
● 1,000
pcs./reel
■ As for Soldering Conditions and Safety Precautions,
Please see Data Files
Explanation of Part Numbers
1
2
3
4
5
6
7
8
9
10
E
L
L
6
P
G
1
0
0
M
Product Code
Inductance
Outer size Height Structure
ELL Choke Coil (Magnetic shielded type )
G
1.6 max.
P
2.0 max.
Dimensions in mm (not to scale)
G
11
Tolerance Design No.
2R2 → 2.2 µH
150 → 15 µH
Series
M → ±20 %
N → ±30 %
1.60 max.
Recommended land patterns in mm (not to scale)
6.0±0.3
Marking
2.9
Date code
1.05
2.7
1.20
6.0±0.3
2.1
0.15
H
0.5
2.1
Type
ELL6GG
ELL6PG
H
1.6 max.
2.0 max.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02
Oct. 2014
Power Inductors
Standard Parts
Series
Series
6GG
Series
6PG
Part No.
ELL6GG1R0N
ELL6GG1R5N
ELL6GG2R2M
ELL6GG2R7M
ELL6GG3R9M
ELL6GG4R7M
ELL6GG6R8M
ELL6GG100M
ELL6GG150M
ELL6GG220M
ELL6GG330M
ELL6GG470M
ELL6GG680M
ELL6GG101M
ELL6PGR08N
ELL6PG1R5N
ELL6PG2R2N
ELL6PG3R3N
ELL6PG3R9N
ELL6PG4R7N
ELL6PG5R6N
ELL6PG6R8N
ELL6PG100M
ELL6PG120M
ELL6PG150M
ELL6PG220M
ELL6PG270M
ELL6PG330M
ELL6PG470M
ELL6PG560M
ELL6PG680M
ELL6PG820M
ELL6PG101M
Inductance
(100 kHz)
(µH)
Tol.
1.0
±30 %
1.5
2.2
2.7
3.9
4.7
6.8
10.0
±20 %
15.0
22.0
33.0
47.0
68.0
100.0
0.8
1.5
2.2
3.3
±30 %
3.9
4.7
5.6
6.8
10.0
12.0
15.0
22.0
27.0
±20 %
33.0
47.0
56.0
68.0
82.0
100.0
RDC
(at 20 °C)
(mΩ)
Tol.
27
36
45
54
60
70
110
±20 %
170
210
300
510
610
860
1480
24
30
37
44
51
58
65
70
110
140
±20 %
150
230
260
300
470
520
700
800
1000
Temperature
Saturation
Rated Current✽1 Rise Current✽2
(mA max.)
(mA max.)
2500
2500
2300
2250
1950
2000
1850
1800
1650
1700
1400
1550
1150
1300
900
1000
800
900
620
850
490
580
400
480
380
410
300
350
3800
2800
2500
2500
2200
2200
1700
2000
1600
1900
1500
1750
1450
1650
1400
1600
1300
1300
1100
1200
1000
1100
800
900
730
800
700
750
550
600
500
550
420
500
400
450
380
400
Marking
1R0
1R5
2R2
2R7
3R9
4R7
6R8
100
150
220
330
470
680
101
R08
1R5
2R2
3R3
3R9
4R7
5R6
6R8
100
120
150
220
270
330
470
560
680
820
101
✽1 Saturation Rated Current : This DC current which causes a 30 % inductance reduction from its nominal value.
✽2 Temperature Rise Current : This indicates the value of current when temperature rise dt/t= 40 °C (at 20 °C).
B-B,Section
R0
.3
ma
x.
B
1.5±0.1
6.4±0.1
B
A,
t
0.4±0.1
4 ° max.
A
7.5±0.1
1.5±0.1
R0
.5
,
0m
ax
.
.1
+00
.50
f1
16.0±0.3
2.0±0.1
4.0±0.1
12.0±0.1
1.75±0.10
Embossed Carrier Tape Dimensions in mm (not to scale)
4 ° max.
6.4±0.1
R0
A-A,Section
.3
ma
x.
Type
ELL6GG
ELL6PG
t
1.8±0.3
2.2±0.3
Tape running direction
Quantity 1,000 pcs./reel
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02
Oct. 2014
Power Inductors
Safety Precautions
(Common precautions for Power Inductors / Wire Wound type)
• When using our products, no matter what sort of equipment they might be used for, be sure to make a written
agreement on the specifications with us in advance. The design and specifications in this catalog are subject
to change without prior notice.
• Do not use the products beyond the specifications described in this catalog.
• This catalog explains the quality and performance of the products as individual components. Before use, check
and evaluate their operations when installed in your products.
• Install the following systems for a failsafe design to ensure safety if these products are to be used in equipment
where a defect in these products may cause the loss of human life or other significant damage, such as damage
to vehicles (automobile, train, vessel), traffic lights, medical equipment, aerospace equipment, electric heating
appliances, combustion/gas equipment, rotating equipment, and disaster/crime prevention equipment.
✽ Systems equipped with a protection circuit and a protection device
✽ Systems equipped with a redundant circuit or other system to prevent an unsafe status in the event of a single fault
Precautions for use
1. Operation range and environments
1 These products are designed and manufactured for general and stan dard use in general elec tron ic
equipment (e.g. AV equipment, home electric appliances, office equipment, information and communication
equipment)
2 These products are not intended for use in the following special conditions. Before using the products, carefully
check the effects on their quality and performance, and determine whether or not they can be used.
• In liquid, such as water, oil, chemicals, or organic solvent
• In direct sunlight, outdoors, or in dust
• In salty air or air with a high concentration of corrosive gas, such as Cl2, H2S, NH3, SO2, or NO2
• In an environment where these products cause dew condensation
2. Handling
1 Do not bring magnets or magnetized materials close to the product. The influence of their magnetic field can
change the inductance value.
2 Do not apply strong mechanical shocks by either dropping or collision with other parts.
Excessive shock can damage the part.
3. Washing of board
Kindly consult the Technical department before washing of the PWB with any cleansing agent, and provide the
washing condition.
4. Resoldering with a soldering iron
The temperature of the tip of the soldering iron should be 360 °C or less, 4 seconds.
And resoldering with a soldering iron should be limited to 1 time, and after that should be cooling these.
5. Mounting side
External force must be less than 5.0 [N] : while mounting.
6. Storage conditions
Normal temperature (–5 to 35 °C), normal humidity (85 % RH max.), shall not be exposed to direct sunlight and
harmful gases and care should be taken so as not to cause dew.
Package markings include the product number, quantity, and country of origin.
In principle, the country of origin should be indicated in English.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02 Sep. 2014