1197
FIBER
SENSORS
Compact Fan Type Ionizer
ER-Q SERIES
Related Information
High-frequency AC Method
■■General terms and conditions.............. F-7
■■Glossary of terms.......................... P.1497
■■Selection guide............................ P.1157~
■■General precautions...................... P.1501
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
SUNXpanasonic.net/id/pidsx/global
website http://www.sunx.com
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Spot charge removal without compressed air
Miniature, ultralight, fast charge removal
A perfect fit for installation in other devices.
• Dimensions: W65 × H60 × D33 mm
W2.559 × H2.362 × D1.299 in
• Net weight: 110 g approx.
• Charge removal Time (± 1,000 V → ± 100 V):
1.5 sec approx. (typical)
Adjustable
Includes volume adjuster to change fan blowing to meet
your needs.
Selection
Guide
Static
Removers
Cleaning Box
Pulse Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
Safe design
Freely mounted: No air hoses necessary
The LED display and output indicate maintenance timing
and problems with the fan.
Mountable like a sensor in cell workbenches or inside
devices.
Simple maintenance
Assembled and disassembled in a single touch, reducing
steps required to replace parts or clean filters.
ER-VW
ER-Q
ER-F
ER-QMS1
Discharge needle unit
Filter
MS-AJ1-A
Compact Fan Type Ionizer
ER-Q SERIES
1198
APPLICATIONS
FIBER
SENSORS
Removing dust on tape before taping
Prevention of part feeder clogging
Prevention of misalignment at crimping
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
ORDER GUIDE
Type
SENSOR
OPTIONS
Change removal time
(±1,000V→±100V)
Appearance
Ion balance
Model No.
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Compact fan type
1.5 sec. approx. (Note)
±10 V or less (Note)
ER-Q
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
Note: Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed.
PLC
HUMAN
MACHINE
INTERFACES
OPTIONS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Designation
Model No.
Description
FA
COMPONENTS
ER-QMS1
The ER-Q mounting bracket. Adjust the air output direction.
MACHINE
VISION
SYSTEMS
ER-QCC2
Length 2 m 6.562 ft
ER-QCC5
UV
CURING
SYSTEMS
Length 5 m 16.404 ft
AC adapter
ER-VAPS1
• IN: 100 to 240 V AC, 50 / 60 Hz, 40 VA
• OUT: 24 V DC, 750 mA
• Ambient temperature: 0 to +40 °C +32 to +104 °F
Discharge needle unit
ER-QANT
Unit with tungsten needles (1 pc.)
Air filter
ER-QFX5
Fan intake filter (5 pcs. per set)
Mounting bracket
Connector-attached cable
• 0.13 mm2 8-core connector cabtyre cable
• Cable outer diameter: ø3.7 mm ø0.146 in
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
CPM
L
W(Horizontal)
100
200
300
400
3.937
7.874 11.811 15.748
Charge removal distance L (mm in)
Charge removal width H (mm in)
Charge removal width W (mm in)
Charge removal field
Charge removal field
(horizontal direction)
(vertical direction)
(Fan speed MAX., filter is mounted) (Fan speed MAX., filter is mounted)
2 sec.
5 sec.
10 sec.
500
19.685
200
7.874
150
5.906
100
3.937
50
1.969
0
0
-50
-1.969
-100
-3.937
-150
-5.906
-200
-7.874 0
0
CPM
L
H(Vertical)
100
200
300
400
3.937
7.874 11.811 15.748
Charge removal distance L (mm in)
Static
Removers
PRECAUTIONS FOR PROPER USE
Refer to p.1501 for general precautions.
• Measured using a 150 mm × 150 mm 5.906 in × 5.906 in
CPM (charge plate monitor). (At center of CPM)
200
7.874
150
5.906
100
3.937
50
1.969
0
0
-50
-1.969
-100
-3.937
-150
-5.906
-200
-7.874 0
0
Selection
Guide
2 sec.
5 sec.
10 sec.
500
19.685
• Never use this product in a device for
personnel protection.
• In case of using devices for personnel
protection, use products which meet laws
and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in
each region or country.
• Do not use this product in places where
there may be a danger of flammable or
combustible items being present.
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
1199
Compact Fan Type Ionizer
ER-Q SERIES
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Compact fan type
Type
Item
ER-Q
Model No.
1.5 sec. approx. (Note 2)
Charge removal time (±1,000 V → ±100 V)
±10 V or less (Note 2)
Ion balance
Power supply voltage
24 V DC ±10%
Power consumption
200 mA or less
High-frequency AC method
Discharge method
±2 kV approx.
Discharge output voltage
Max. fan speed
6.4 m/s (Note 2)
Max. fan volume
0.2 m3/min.
NPN transistor / open collector
• Max sink current: 50 mA
• Applied voltage: 30 V DC or less (between output terminal and 0 V)
• Residual voltage: 1 V or less (at input current of 50 mA)
Output(CHECK, ALARM)
SIMPLE
WIRE-SAVING
UNITS
Check: On when discharge check (Note 3) detected
Off at all other times
Error: O
ff when discharge error or fan error (Note 3) detected
On at all other times
Output operation
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
Incorporated
Short-circuit protection
Discharge (DSC): Green LED, Alarm (ALARM): Red LED
Indicators
0.02 ppm or less (Note 2)
Ozone generation amount
0 to +50 °C +32 to +122 °F (No dew condensation), Storage: –10 to +65 °C +14 to +149 °F
Ambient temperature
35 to 65% RH (No dew condensation), Storage: 35 to 65% RH
Ambient humidity
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Vibration resistance
C (capacitor) grounding
Grounding method
Material
Enclosure: PBT, Discharge needle: Tungsten
Weight
Net weight: 110 g approx.
Connector for wiring: 1 set
[Manufactured by Molex: Housing (5557-08P), Terminal (5556T)]
Accessory
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed.
3) Discharge check: Drop in discharging status detected. Discharge error: Abnormal discharge detected. Fan error: Fan operating problem detected.
UV
CURING
SYSTEMS
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram
Connector terminal No.
Selection
Guide
Static
Removers
D1
5
Cleaning
Box
Main circuit
ER-X
ER-TF
D2
Tr1
7
8
7
6
5
(+)
4
3
2
1
D3
Tr2
(Orange) Check output
Load
(Front view)
50 mA max.
ZD1
ZD2
ER-VS02
1
2
ER-Q
4
Internal circuit
+
(Black) Error output
8
Load
50 mA max. +
ER-VW
ER-F
Color code
(Brown) +24 V
6 COM
Pulse
Air-gun
Electrostatic
Sensor
Connector terminal arrangement
(Blue) 0 V
−
−
30 V DC max.
COM (−)
(Green) F.G.
User’s circuit
Symbols … D1: Reverse supply polarity protection diode
D2, D3: Input protection diode
ZD1, ZD2, : Surge absorption zener diode
Tr1, Tr2, : NPN output transistor
24V DC
±10 %
Terminal
No.
Description
Color code
1
0V
Blue
2
COM (–)
─
3
N.C. (no connection)
─
4
F.G.
Green
5
+24 V
Brown
6
COM (+)
─
7
Check output
Orange
8
Error output
Black
5
59
8
83
Compact Fan Type Ionizer
DIMENSIONS (Unit: mm in)
1200
The CAD data in the dimensions can be downloaded from our website.
ER-Q
Ionizer main unit
2-ø3.5 ø1.378
mounting hole
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
Discharge indicator
(Green)
60
2.362
PRESSURE /
FLOW
SENSORS
Power switch
INDUCTIVE
PROXIMITY
SENSORS 5.5
Filter cover
ø3.7 ø0.146 cable 0.5 m 1.64 ft
2-ø3.5 ø1.378
mounting hole
Fan speed control
PARTICULAR
USE
SENSORS
29
1.142
33
1.299
Connector 5559-08P
manufactured by Molex
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
2-M3 screws (depth 10 0.394) (Note)
WIRE-SAVING
SYSTEMS
Alarm indicator (Red)
Note: S
crew threads exclusive for mounting
brackets. Do not use them in mounting
with other products.
When mounting this product directly to a
case or such, fix it with M3 screws using
2-ø3.5 ø1.378 mounting holes.
25.4
1.000
Discharge indicator
(Green)
Power switch
19.8
0.780
5.5
0.217
over
29
1.142
33
1.299
ER-QMS1
Mounting bracket (Optional)
Assembly dimensions
60
2.362
25.4
1
2-ø3.3 0.130
5.5
0.217
(
(
83
3.268
60
2.362
19.6
0.772
16.5
0.650
54
2.216
48
1.890
t 1.2
t 0.047
40
50
56
1.575 1.969 2.205
M4×8 0.315
Airflow direction
adjustment screw
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
UV
CURING
SYSTEMS
48
1.890
4-ø4.5 0.177
MEASUREMENT
SENSORS
MACHINE
VISION
SYSTEMS
16.5
0.650
M3×10 0.394
32.5
(1.280
)
50
1.969
60°
Selection
Guide
Static
Removers
8.6
(0.339
)
ø46
40
50
56
1.575 1.969 2.205
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
4.2
0.165
ø46
65
(2.560
)
M4×8 0.315
Airflow direction
adjustment screw
83
(3.268
)
72
2.835
50
1.969
60°
)
)
34.2
(1.346
)
30.2
(1.189)
42
1.654
19
0.748
4-ø4.5 0.177
LASER
SENSORS
MICRO
PHOTOELECTRIC
2-M3 screws (depth 10 0.394)
(Note)
SENSORS
Fan speed control
Alarm indicator (Red)
52
2.047
Discharge needle unit
FIBER
SENSORS
PHOTOELECTRIC
SENSORS
65
2.559
58
2.283
3.5
0.138
3.5
0.138
Ion air outlet
m 1.64 ft
r 5559-08P
ured by Molex
ER-Q SERIES
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
4.2
0.165
ER-F
0.21
很抱歉,暂时无法提供与“ER-QANT”相匹配的价格&库存,您可以联系我们找货
免费人工找货