1175
FIBER
SENSORS
Wide-area Ionizer
Steady-state DC Method
ER-TF SERIES
Related Information
■■General terms and conditions.............. F-3
■■Glossary of terms.......................... P.1591
■■Selection guide............................ P.1155~
■■General precautions...................... P.1595
LASER
SENSORS
PHOTOELECTRIC
SENSORS
No compressed air necessary
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
panasonic.net/id/pidsx/global
Slim in shape, Wide in charge removal area,
An evolutionary form in expression
Safe design
Available quiet fan cover (optional)
A monitoring function stops discharge operation if any
foreign material or object is detected in the discharge
unit. This capability provides peace of mind when
working with the unit since you can rest assured that the
high-voltage circuit will stop if your finger approaches the
unit.
An available fan cover reduces fan suction noise without
reducing air volume.
Flexible layout
Thanks to its space-saving design, the ER-TF series
delivers a sufficiently large charge removal area while
allowing you to make effective use of your workspace. It
can be mounted on a shelf or pipe or placed directly on
the working surface. The unit adapts flexibly to the local
working environment.
Selection
Guide
Static
Removers
Pulse Air-gun
Cleaning Box
(Illustration)
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Easy maintenance
Discharge units can be removed with a single touch,
making it easy to clean them or replace them as they
naturally wear down. Units can also be cleaned with a
commercially available ultrasonic cleaner.
Overhead
setup
Desktop
setup
Wide-area Ionizer
ER-TF SERIES
APPLICATIONS
1176
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Overhead
setup
Front
setup
Desktop
setup
PARTICULAR
USE SENSORS
Indicators showing operation conditions
This section will now explain the indicator lights that
indicate such abnormalities as maintenance time of the
discharge needle unit and the decrease in the amount of
ventilation due to filter clogging.
POWER
(Green LED)
FAN
(Yellow LED)
ERROR
(Red LED)
BAR
(Yellow LED)
CHECK
(Orange LED)
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
ERROR indicator:
Lights up when an intrusion of a foreign object into the
discharger is detected by the entry detection function,
or when an abnormal discharge, air intake constraint
caused by clogged filter, or any other abnormality of the
fan is detected.
CHECK indicator:
Lights up when it is time for maintenance of the
discharge needle unit, or when a drop in the fan speed
resulting from filter clogging is detected.
FAN indicator:
Lights up when a fan error or a fan check is detected.
BAR indicator:
Lights up when a discharger error or a discharger check
is detected.
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
Airflow adjustable in 4 levels
Easy filter cleaning
Fan speed can be
adjusted in 4 levels.
By setting the fan speed
to MAX, speedy static
removal of wide area is
possible.
The fan air intake filter
can be easily taken
out by sliding open
the cover. This greatly
reduces the man-hour in
cleaning.
Silent fan cover (option) is available.
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse Air-gun
Cleaning Box
Without decreasing the airflow,
it is possible to reduce noise
during fan suction.
You can easily attach the silent
fan cover to the front of the main
unit fan with a single step.
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Silent fan cover
(optional)
ER-TFSC
1177
FIBER
SENSORS
LASER
SENSORS
Wide-area Ionizer
ER-TF SERIES
ORDER GUIDE
Ionizer main unit
PHOTOELECTRIC
SENSORS
Type
Appearance
MICRO
PHOTOELECTRIC
SENSORS
Charge removal time
(±1,000 V → ±100 V)
Ion balance
AREA
SENSORS
Model No.
ER-TF04-EX
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
Wide-area fan type
1 sec. approx. (Note 1)
±10 V or less (Note 2)
ER-TF06-EX
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
ER-TF08-EX
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Notes: 1) Typical value at 200 mm 7.874 in from directly in front of air outlet at the unit center at maximum fan speed.
2) Typical value at 300 mm 11.811 in from directly in front of air outlet at the unit center at maximum fan speed.
3) Please prepare an AC cable separately as it is needed.
The following cables are available as optionals:
CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)
STATIC
CONTROL
DEVICES
Connector configuration
(IEC 60320 C7)
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
OPTIONS
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Designation
AC cable
Mounting unit
Air filter
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Model No.
CN-ACCN-C2 AC cable (conforming to CCC), Length: 2 m 6.562 ft
CN-ACKR-C2 AC cable (conforming to KTL), Length: 2 m 6.562 ft
ER-TF06MS1
Mounting unit for ER-TF06-EX. Allows easy
attachment or detachment of the main unit.
ER-TFF×10
Air filter for fan air intake part (10 pcs. per set)
Discharge needle unit ER-TFANT
Silent fan cover
Description
ER-TFSC
Unit with tungsten needles (1 pc.)
To be mounted on the front part of the fan unit
as a cover to reduce the fan blowing sound.
Mounting unit
Silent fan cover
•ER-TF06MS1
•ER-TFSC
Air filter
•ER-TFF×10
Discharge needle unit
•ER-TFANT
Wide-area Ionizer
ER-TF SERIES
1178
SPECIFICATIONS
FIBER
SENSORS
Type
Item
Model No.
LASER
SENSORS
Wide-area fan type
ER-TF04-EX
ER-TF06-EX
ER-TF08-EX
PHOTOELECTRIC
SENSORS
CE marking directive compliance
EMC Directive, RoHS Directive
Charge removal time (±1,000 V → ±100 V)
1 sec. approx. (Note 2)
Ion balance
±10 V or less (Note 3)
AREA
SENSORS
0.02 ppm or less (Note 3)
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Ozone generation
Power supply voltage
Accessory AC adapter input: 100-240 V AC ±10 % 50/60 Hz (Note 4)
(Output: 24 V DC)
Power consumption
80 VA or less (at 100 V: 70 VA or less)
Discharge method
Output operation
±6,000 V approx.
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
OFF if abnormal discharge, object inserted into discharge window or fan problem detected; normally ON
Bar
Fan
Indicators
Short-circuit protection
Incorporated
Green LED (Lights up when the power is ON)
ERROR
Red LED (Lights up when discharge part error or fan error is detected)
CHECK
Orange LED (Lights up when discharge part check or fan check is detected)
Fan status
Ambient temperature
Weight
Accessories
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
MEASUREMENT
SENSORS
Yellow LED (Lights up when discharge part error or discharge part check is detected)
STATIC
CONTROL
DEVICES
Yellow LED (Lights up when fan error or fan check is detected)
LASER
MARKERS
0 to +50 °C +32 to +122 °F (No dew condensation), AC adapter: 0 to +40 °C +32 to +104 °F
Ambient humidity
Material
PARTICULAR
USE
SENSORS
WIRE-SAVING
SYSTEMS
POWER
Discharge part
status
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Steady-state DC
Discharge output voltage
Error output
MICRO
PHOTOELECTRIC
SENSORS
35 to 65 % RH (No dew condensation allowed)
Bar unit enclosure: ABS, Fan unit enclosure: ABS, Discharge needles: Tungsten, Mounting bracket: Cold rolled carbon steel (SPCC)
Net weight: 1.0 kg approx.
Net weight: 1.2 kg approx.
Net weight: 1.4 kg approx.
AC adapter (Note 3), F.G. connection cable: 1 pc., Spare replacement filters: 5 pcs., Three-pronged outlet with ground pin: 1 pc., Blindfold seals: 2 sheets
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Typical value at 200 mm 7.874 in from directly in front of air outlet at the unit center at maximum fan speed.
3) Typical value at 300 mm 11.811 in from directly in front of air outlet at the unit center at maximum fan speed.
4) Please prepare an AC cable separately as it is needed.
The following cables are available as optionals:
CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
1179
Wide-area Ionizer
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
I/O circuit diagram
D
PHOTOELECTRIC
SENSORS
6
Tr
2
3
ENERGY
MANAGEMENT
SOLUTIONS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Charge removal time
30
Airflow 1
Airflow 2
Airflow 3
Airflow 4
35
30
25
CPM
Center
20
L
15
10
10
0
–10
–20
CPM
Center
L
0
–30
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
0
Charge removal field
(Horizontal direction)
400
15.748
300
11.811
200
7.874
100
3.937
0
Airflow 1
Airflow 2
Airflow 3
Airflow 4
20
5
0
5
3
2
1
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
-100
-3.937
-200
-7.874
-300
-11.811
-400
-15.748 0
2 sec.(Airflow 2)
5 sec.(Airflow 2)
10 sec.(Airflow 2)
2 sec.(Airflow 4)
5 sec.(Airflow 4)
10 sec.(Airflow 4)
Ion balance (Horizontal direction)
[Airflow 4]
30
20
CPM
Center
10
0
–10
–20
+Direction
L
W
-Direction
Charge removal
distance L (mm in)
L=300 mm 11.811 in
L=500 mm 19.685 in
L=1000 mm 39.370 in
CPM
Center
–30
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
+Direction
L
W
-Direction
-400 -300 -200 -100 0 100 200 300 400
-15.748 -11.811 -7.874 -3.937
3.937 7.874 11.811 15.748
Charge removal width W (mm in)
ER-TF06-EX
Charge removal time
Correlation between charge
removal distance and ion balance
30
40
Airflow 1
Airflow 2
Airflow 3
Airflow 4
35
30
25
CPM
Center
20
L
15
10
Airflow 1
Airflow 2
Airflow 3
Airflow 4
20
10
0
–10
–20
5
0
CPM
Center
L
0
–30
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
0
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
Charge removal field
(Horizontal direction)
400
15.748
300
11.811
200
7.874
100
3.937
0
-100
-3.937
-200
-7.874
-300
-11.811
-400
-15.748 0
2 sec.(Airflow 2)
5 sec.(Airflow 2)
10 sec.(Airflow 2)
2 sec.(Airflow 4)
5 sec.(Airflow 4)
10 sec.(Airflow 4)
Ion balance (Horizontal direction)
[Airflow 4]
30
20
CPM
Center
10
0
–10
–20
+Direction
L
W
-Direction
Charge removal
distance L (mm in)
L=300 mm 11.811 in
L=500 mm 19.685 in
L=1000 mm 39.370 in
CPM
Center
–30
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
+Direction
L
W
-Direction
-400 -300 -200 -100 0 100 200 300 400
-15.748 -11.811 -7.874 -3.937
3.937 7.874 11.811 15.748
Charge removal width W (mm in)
ER-TF08-EX
Charge removal time
ER-VW
Charge removal time (sec.)
Airflow 1
Airflow 2
Airflow 3
Airflow 4
35
30
25
CPM
Center
20
L
15
10
Airflow 1
Airflow 2
Airflow 3
Airflow 4
20
10
0
–10
–20
5
0
Correlation between charge
removal distance and ion balance
30
40
ER-Q
ER-F
Correlation between charge
removal distance and ion balance
40
ER-X
ER-VS02
6
4
ER-TF04-EX
Electrostatic
Sensor
ER-TF
F.G.
Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM)
Charge removal time (sec.)
UV
CURING
SYSTEMS
COM (–)
+V
6
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
0V
5
Ion balance (V)
HUMAN
MACHINE
INTERFACES
COM (–)
4
Ion balance (V)
PLC
Error output
3
CPM
Center
L
0
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
–30
0
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
Charge removal field
(Horizontal direction)
400
15.748
300
11.811
200
7.874
100
3.937
0
-100
-3.937
-200
-7.874
-300
-11.811
-400
-15.748 0
2 sec.(Airflow 2)
5 sec.(Airflow 2)
10 sec.(Airflow 2)
2 sec.(Airflow 4)
5 sec.(Airflow 4)
10 sec.(Airflow 4)
Ion balance (Horizontal direction)
[Airflow 4]
30
20
Ion balance (V)
LASER
MARKERS
2
Symbols … D : Reverse supply polarity protection
diode
ZD : Surge absorption zener diode
Tr : NPN output transistor
Charge removal width W (mm in)
STATIC
CONTROL
DEVICES
N.C. (no connection)
30 V DC or less
Charge removal width W (mm in)
MEASUREMENT
SENSORS
Terminal name
1
Note: Please prepare an AC cable separately as it is needed.
The following cables are available as optionals:
CN-ACCN-C2: AC cable (conforming to CCC)
CN-ACKR-C2: AC cable (conforming to KTL)
Charge removal time (sec.)
WIRE-SAVING
SYSTEMS
+
50 mA max.
Internal circuit
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Load
Charge removal width W (mm in)
PARTICULAR
USE
SENSORS
Error output
Ion balance (V)
INDUCTIVE
PROXIMITY
SENSORS
Terminal No.
AC cable (Note)
F.G. terminal [connected internally to 0 V and COM (–).]
ZD
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
+V
0V
Ion balance (V)
AREA
SENSORS
4
Main circuit
MICRO
PHOTOELECTRIC
SENSORS
5
Terminal position
AC adapter (Accessory)
Ion balance (V)
LASER
SENSORS
ER-TF SERIES
CPM
Center
+Direction
L
W
-Direction
200 400 600 800 1000 1200 1400 1600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
10
Charge removal
distance L (mm in)
L=300 mm 11.811 in
L=500 mm 19.685 in
L=1000 mm 39.370 in
0
–10
–20
–30
CPM
Center
+Direction
L
W
-Direction
-400 -300 -200 -100 0 100 200 300 400
-15.748 -11.811 -7.874 -3.937
3.937 7.874 11.811 15.748
Charge removal width W (mm in)
Wide-area Ionizer
PRECAUTIONS FOR PROPER USE
ER-TF SERIES
1180
Refer to p.1595 for general precautions.
• This product is to remove static electricity for industrial use. Never use this product for medical equipment etc.
relating to maintenance / supervision of human life or body, for prevention of accidents which damage a human
life or properties, or for safety maintenance.
• Do not use this product near or around surroundings containing any dangerous materials, such as combustible
material and flammable material.
• This product emits ozone. In order for this product to be used in an airtight room, be sure to keep the room ventilated.
• Do not place any objects that may obstruct the inflow of air within 10 mm 0.394 in of the front of the fan air intake
part. Doing so may cause accident or product malfunction.
• Be sure to ground the main body of this product via ground terminal to ensure electrical shock prevention and
reliable charge removal.
• Since the charge needle is applied with high voltage, never touch the discharge needle, or an electric shock may result.
• Since the tip of the discharge needle is sharp, take sufficient care in handling the discharge needle, or injuries may result.
• Always be sure to turn off the power before carrying out
any care and maintenance of the product.
• The tip of the discharge needle is sharp, so be careful not
to touch it while cleaning.
• When the product is used for long periods of time, dust
and other foreign particles may accumulate on the
discharge needle, the area around it, and on the fan filter.
Clean regularly (discharge needle: about once a week,
air filter: about once every two months), otherwise their
charge removal performance will drop and operating
problems or accidents may occur.
• The discharge needle is a consumable part. If the charge
removal performance is not restored after cleaning the
discharge needle, the discharge needle unit should be
replaced. All of the discharge needle units should be
replaced at the same time.
• Do not place any objects or any other charge removal
equipment within 100 mm 3.937 in of the ionized air
outlet front (refer to the illustration below), as they may
affect operation and performance of the ionizer.
45°
100 mm
3.937 in
Air outlet
Air outlet
Ionizer
45°
45°
45°
100 mm
3.937 in
Forbidden zone
Forbidden zone
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from our website.
Ionizer
C
D
F
B
5.5
0.217
15.5 0.610
4.5 0.177
12 0.472
(A)
80 3.150
4-M4 (thru-hole)
4-M5 (thru-hole)
61
2.402
(50 1.969)
(4 0.158)
Discharge needle holder
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
MACHINE
VISION
SYSTEMS
Air outlet
143
5.630
E
F
G
351.5
13.839
511.5
20.138
671.5
26.437
290
11.417
450
17.717
610
24.016
190
7.480
350
13.780
510
20.079
255
10.039
400
15.748
560
22.047
120
4.724
280
11.024
440
17.323
Fan speed switch
Pulse
Air-gun
Cleaning
Box
Power connector
Electrostatic
Sensor
ER-X
ER-TF
Air inlet
D
Static
Removers
Mounting bracket
45.3 1.784
Power indicator (Green)
Error indicator (Red)
C
8.3
0.327
Selection
Guide
43.5
1.713
24
0.945
44 1.732
Check Indicator (Orange)
414 240
ER-TF04-EX 16.299
9.449
574 400
ER-TF06-EX 22.598
15.748
734 560
ER-TF08-EX 28.898
22.047
AREA
SENSORS
60
2.362
G
E
B
MICRO
PHOTOELECTRIC
SENSORS
UV
CURING
SYSTEMS
47 48
1.850 1.890
A
PHOTOELECTRIC
SENSORS
FA
COMPONENTS
ER-TF□-EX
Model No.
LASER
SENSORS
PARTICULAR
USE
SENSORS
Maintenance
Mounting
FIBER
SENSORS
Power switch
92.2 3.630
98 3.858
(100 3.937)
Discharger status indicator (Yellow)
Fan status indicator (Yellow)
ER-VS02
ER-VW
ER-Q
ER-F
很抱歉,暂时无法提供与“ER-TFSC”相匹配的价格&库存,您可以联系我们找货
免费人工找货