1159
FIBER
SENSORS
Area Ionizer
Pulse AC Method
ER-X SERIES
Related Information
■■General terms and conditions.............. F-7
■■Glossary of terms.......................... P.1497
■■Selection guide............................ P.1157~
■■General precautions...................... P.1501
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
panasonic.net/id/pidsx/global
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
High-Speed, Wide Area Charge Removal
"Fast Charge Removal", "Airless", "Low-Pressure". Three charge removal modes for diverse application coverage.
The ER-X series offers an airless charge removal capability to eliminate the need for compressed air in addition to
low pressure and high speed compressed air based modes. Furthermore, it supports dual-head configurations for
expanded application coverage.
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Head 1
Head 2
Selection
Guide
Static
Removers
Cleaning Box
Pulse Air-gun
Electrostatic
Sensor
ER-X
ER-TF
Fast
Charge
Removal
Airless
or LowPressure
ER-VS02
ER-VW
ER-Q
ER-F
Massive ion discharge when using air reduces charge removal time.
Prevents dust dispersion and cleanliness degradation!
By applying a compressed air source, the ion volume
increases providing an improved tact time for substrate
ionization. This makes the ER-X suitable for applications
such as electronic paper and thin film solar cells, where
charge removal time is directly linked to productivity.
The ER-X series can effectively remove surface charges
with an air pressure of less than 0.05 MPa. With the
advantage of minimal dust dispersion, it is suitable
for charge removal in semiconductor, FPD (mobile
panel), and other applications that require high degree
of cleanliness. The presence of air also helps prevent
adhesion of dust to the discharge needles, requiring less
cleaning than in the airless charge removal mode.
Area Ionizer
ER-X SERIES
APPLICATIONS
1160
FIBER
SENSORS
Removal of static charges on laminate film
Prevention of part feeder clogging
High-speed charge removal on FPCs
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Removing dust while separating TAB protective film
PARTICULAR
USE SENSORS
Preventing static damage to module components
SENSOR
OPTIONS
ER-X008
SIMPLE
WIRE-SAVING
UNITS
ER-X008
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
Super-compact slim head
Pulse AC method for faster charge removal
By thoroughly redesigning the discharge needle, we
have created a super-compact slim head that combines
high-speed charge removal*1 with a maintenance-saving
design*2. The ER-X series can be embedded in, or
retrofitted onto, equipment that did not provide enough
space for antistatic measures in the past.
The ER-X series has adopted the pulse AC method
that alternately applies positive and negative voltages
to each discharge needle. This enables generation and
discharge of a large amount of ions, resulting in faster
charge removal. Select from eight pulse frequencies
according to your application, from 100 Hz for charge
removal on nearby or moving workpieces to 1 Hz for
charge removal on far-away workpieces or in a threedimensional space.
*1 Pulse AC method with built-in air tubes (max. pressure 0.5 MPa)
*2 Discharge needle air barrier structure, discharge needle unit for simple
need replacement
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Charge removal time characteristics (TYPICAL)
30 mm
(1.181 in)
22 mm
(0.866 in)
Measured at a charge removal distance of 100 mm 3.937 in using
a 150 × 150 mm 5.906 × 5.906 in CPM (at center of CPM).
1,000
Charge voltage (V)
Angle adjustment screw
360degree
angle
adjustment
− Conventional type, with airflow, 0.05 MPa
− ER-X032, airless
− ER-X032, with airflow, 0.05 MPa
800
Cleaning Box
Pulse Air-gun
600
Electrostatic
Sensor
Conventional type
400
200
Selection
Guide
Static
Removers
ER-X
ER-X
ER-TF
0
1
2
3
Charge removal time (sec.)
4
ER-VS02
ER-VW
ER-Q
ER-F
1161
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Area Ionizer
ER-X SERIES
Automatic ion balance control
Discharge needle air barrier design for reduced contamination
The ER-X series provides an automatic ion balance
control mechanism that senses the amount of ions being
generated (which changes according to environmental
factors) and compensate for this deviation in the
controller, thus maintaining a highly stable ion balance
as an original operator setting.
A barrier of clean air around the discharge needle keeps
foreign matter from adhering to it, preventing degraded
performance. Additionally, by using separate air sources
for the discharge needle barrier and ion transport, the
ER-X series keeps discharge from becoming unstable
due to pressure concentration, allowing the device to
efficiently generate and transport ions.
Example of variable discharge
frequency/ion balance
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
Air barrier
structure
Efficient charge removal
structure using 0.05 MPa airflow
Discharge needle after 1 month
Efficient charge
removal structure
Variable discharge
frequency
Variable ion balance
Carefully designed to prevent contamination in manufacturing processes
In consideration of the manufacturing process (secondary cells etc.), the ER-X series heads neither use copper nor
plate processing. This minimizes the risk of contamination with foreign substances.
Flat discharge surface for easy cleaning
Discharge needle unit for simple needle replacement
The ER-X series heads have a flat discharge face,
allowing effortless cleaning of the discharge needles and
air outlets by simply brushing along the groove provided.
The removable discharge needle unit (including a set
of four needles) substantially simplifies maintenance.
To remove the unit, just slide it toward both ends as
indicated by the arrows.
HUMAN MACHINE
INTERFACES
Discharge needles
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
Air outlets
Discharge needle unit
UV CURING
SYSTEMS
Groove
Selection
Guide
Static
Removers
Commercial brush
Dual Head Configuration for Enhanced Charge Area and Layout Expansion
Cleaning Box
1
Controller
Pulse Air-gun
controller
Electrostatic
Sensor
• Different heads can be combined.
• Charge removal is possible with a layout that places
heads on either side of the workpiece.
• The charge removal efficiency can be increased by
synchronizing the two heads.
High-voltage unit
ER-X
ER-TF
ER-VS02
ER-VW
Head 1
+ 2 heads
High-voltage unit
ER-Q
ER-F
Head 2
Charge removal modes can be selected.
Charge removal in "fast" or "low-pressure" mode requires compressed air, while "airless or low-pressure" mode does
not need compressed air.
Area Ionizer
ER-X SERIES
Multifunction controller to which 2 heads can be connected
FIBER
SENSORS
This all-in-one model controller features a range of functionality that allows it to perform optimal charge removal.
Level meter indicator (green)
Indicates static buildup around
the head or the amount of ion
generated from the head.
Discharge indicator (green)
Lights up during discharge.
CHECK indicator (orange)
Lights up when dirt, wear, etc. of the
discharge needle is detected.
ERROR indicator (red)
Lights up when abnormal discharge is
detected.
Discharge frequency setting switch
Discharge control switch
ON: Discharge allowed
OFF: Discharge halt
SET UP button
Stores the settings for the
amount of ion and the check
threshold in memory.
Discharge control input
Turn ion generation on and off
from an external device.
Alarm output, error output
Report maintenance timing and
malfunctions to an external
device.
1162
Select from eight ion generation
frequencies ranging from 100 Hz to 1
Hz according to your application.
Ion balance setting switch
Adjust the ion balance to any of 15
levels according to the strength of the
charge on the workpieces.
Various setting switch
• Check level changeover switch
Set the maintenance notification level
to “standard” or “high-sensitivity.”
• Ion balance control switch
Enable or disable the ion balance
auto control function.
• Indicator changeover switch
Set the level meter indicator display
mode to “charge strength display” or
“ion generation volume display.”
• 2 heads control switch
Set the ion generation timing for
the two heads to “synchronize” or
“inverse.”
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Static
Removers
Cleaning Box
Pulse Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
1163
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Area Ionizer
ER-X SERIES
ORDER GUIDE
Heads
Head connection cable is not supplied with the head. Please order it separately.
Type
Charge removal time
(±1,000 V→±100 V)
Appearance
Ion balance
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
Bar type
1 sec. approx. (Note 1)
INDUCTIVE
PROXIMITY
SENSORS
±30 V or less
(Note 1, 2)
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
Effective charge
removal width
Model No.
80 mm 3.150 in
approx.
ER-X008
160 mm 6.299 in
approx.
ER-X016
320 mm 12.598 in
approx.
ER-X032
480 mm 18.898 in
approx.
ER-X048
640mm 25.197 in
approx.
ER-X064
Notes: 1) In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.
2) Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than ±10°C ambient temperature change, set
the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.
Controller
Power cable is not supplied with the controller. Please order it separately.
Type
Appearance
Model No.
Number of heads connected
Output
ER-XC02
Max. 2 units
PhotoMOS relay
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
Standard type
Note: When using the ER-X008, use the new controller ER-XC02. The new controller ER-XC02 is compatible with existing heads of the ER-X series.
The new controller can be distinguished as follows:
New ER-XC02 controller
MACHINE
VISION
SYSTEMS
HEAD
1
Head connection cable
Static
Removers
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
ER-XC02
DSC
DSC
CHECK
CHECK
ERROR
UV
CURING
SYSTEMS
Selection
Guide
Old ER-XC02 controller
ER-XC02
Appearance
+
+
0
0
−
−
ERROR
HEAD
HEAD
2
1
The front
panel design
is changed.
+
+
0
0
−
−
HEAD
2
Head connection cable is not supplied with the head. Please order it separately.
Model No.
Description
ER-XCCJ2H
Length: 2 m 6.562 ft, Net weight: 120 g approx.
ER-XCCJ5H
Length: 5 m 16.404 ft, Net weight: 290 g approx.
ER-XCCJ10H
Length: 10 m 32.808 ft, Net weight: 560 g approx.
Cabtyre cable with
both connector
Area Ionizer
ER-X SERIES
1164
OPTIONS
Designation
Power cable
FIBER
SENSORS
Model No.
Description
ER-XCC2
Length: 2 m 6.562 ft,
Net weight: 80 g approx.
ER-XCC5
Length: 5 m 16.404 ft,
Net weight: 190 g approx.
0.15 mm2 10-core cabtyre cable with
connector
Cable outer diameter: ø5.3 mm
ø0.209 in
ER-XAPS-EX IN: 100 to 240 V AC, 50 / 60 Hz
OUT: 24 V DC, 1.5 A
(Note 1)
AC adapter
ER-XAPS
AC cable
Discharge
needle unit
Discharge part
protective cover
Power cable
• ER-XCC□
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AC adapter
• ER-XAPS-EX
Ambient temperature: 0 to +40 °C +32 to +104 °F
Ground wire: 3.7 m 12.139 ft
AC cable: 1 pc., Cable length 1.8 m 5.906 ft, Rating 125 V AC (Note)
Wiring connector terminals: 6 pcs.
LASER
SENSORS
• ER-XAPS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
CN-ACCN-C2 AC cable (conforming to CCC), Length: 2 m 6.562 ft
INDUCTIVE
PROXIMITY
SENSORS
CN-ACKR-C2 AC cable (conforming to KTL), Length: 2 m 6.562 ft
PARTICULAR
USE
SENSORS
ER-XANT
Unit with replacement tungsten needles: 1 pc.
ER-XANT2
For ER-X008 only. Unit with replacement tungsten needles: 1 pc.
ER-XACVR
For ER-X016/X032/X048/X064.
Enables to prevent electric shock by mounting to the heads.
2 pcs per set. (Note 2)
Material: polycarbonate Weight: 20 g approx. (1 set)
* No effect on charge removal capacity of the heads by mounting a
discharge part protection cover
Notes: 1) Rating of the AC cable is 125 V AC. In case using at more than 125 V, prepare a proper cable by yourself or purchase our optional cable CN-ACCN-C2 or CN-ACKR-C2. And, the AC cable is not enclosed
with ER-XAPS-EX.
2) The number of set(s) you need depends on the head model No.
Model No.
No. of set
(2 pcs per set)
ER-X016 ER-X032 ER-X048 ER-X064
1 set
2 set
3 set
4 set
Discharge needle unit
• ER-XANT
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Discharge part protective cover
• ER-XACVR
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
1165
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Area Ionizer
ER-X SERIES
SPECIFICATIONS
Heads
Type
Item
Model No.
Effective charge removal width
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
ER-X032
80 mm 3.150 in approx.
160 mm 6.299 in approx.
Ion balance
±30 V or less (Note 1, 2)
Discharge method
Pulse AC method
Discharge output voltage
±7,000 V approx.
Ozone generation
0.01 ppm or less
Maximum air pressure
ER-X048
ER-X064
320 mm 12.598 in approx. 480 mm 18.898 in approx. 640 mm 25.197 in approx.
1 second or less (Note 1)
0.5 MPa
Applicable fluid
Air (dried clean air) (Note 3)
Ambient temperature
0 to +50 °C +32 to +122 °F (No dew condensation), Storage: –10 to +65 °C +14 to +149 °F
Ambient humidity
35 to 65 % RH, Storage: 35 to 85 % RH
Vibration resistance
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance
100 m/s2 acceleration (10 G approx.), in X, Y and Z directions for three times each
Enclosure grounding method
Floating
Main unit enclosure: PPS, Stainless steal (SUS)
Head mounting bracket: Stainless steal (SUS), Discharge needle: Tungsten
Material
Net weight
330 g approx.
410 g approx.
530 g approx.
650 g approx.
780 g approx.
Notes: 1) In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.
2) Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than ±10 °C ambient temperature change, set
the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.
3) Dried clean air is the air passing through air dryer (dew point –20 °C –4 °F approx.) and air filter (mesh size 0.01 μm 0.0004 mil approx.)
Controller
Type
Item
Model No.
Number of heads connected
Supply voltage
Current consumption
Indictor
DSC (Discharge)
Controller
ER-XC02
Maximum 2 units
24 V DC ±10 %
450 mA or less when connecting 1 heads, 800 mA or less when connecting 2 heads
Displays status of Head 1 and 2
Green LED (lights up when discharging)
CHECK
Orange LED (lights up when dirt, wear, etc. of the discharge needle is detected)
ERROR
Red LED (lights up when abnormal discharge is detected)
Level meter
Static
Removers
ER-X016
Charge removal time
Output
Selection
Guide
Head
ER-X008
ALARM
ERROR
COM (Common)
Output operation
Short-circuit protection
Discharge control input
(DSC OFF)
Ambient temperature
Ambient humidity
Voltage withstandability
Green LED (5 levels, lights up depending on amount of the charge or ion generation)
PhotoMOS relay output
• Maximum load current: 100 mA
• Applied voltage: 30 V DC or less (between output-output common)
• Residual voltage: 1.5 V or less (at load current of 100 mA)
ALARM: ON when dirt or wear of the discharge needle is detected;
OFF when operation is normal.
ERROR: OFF when abnormal discharge is detected;
ON when operation is normal.
Incorporated (automatic reset type)
Discharge allowed: Open,
Discharge halt: 24 V or 0 V shorted
0 to +50 °C +32 to +122 °F (No dew condensation), Storage: –10 to +65 °C +14 to +149 °F
35 to 65 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
20 MΩ, or more, with 250 V megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance
Enclosure grounding method
Material
Weight
Accessories
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each
Floating
Enclosure: ABS
130 g approx.
Power supply / I/O connector: 1 set (Housing 5557-10R, Terminal 5556TL [manufactured by Molex])
Ground wire (3.7 m 12.139 ft approx.): 1 pc.
Area Ionizer
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
1166
ER-X SERIES
Please contact our office for details on data that is not listed here.
LASER
SENSORS
Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM)
Common
PHOTOELECTRIC
SENSORS
Correlation between charge removal
Correlation between charge removal
Correlation between charge removal
distance and charge removal time (50 Hz) distance and charge removal time (10 Hz) distance and charge removal time (1 Hz)
200
100
0
0.1
0.2
0.3
0.4
0.5
─ Airless
─ 0.005 MPa
─ 0.1 MPa
─ 0.3 MPa
─ 0.5 MPa
8
6
CPM
Center
L
4
2
0
10
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
Applied pressure (MPa)
─ Airless
─ 0.005 MPa
─ 0.1 MPa
─ 0.3 MPa
─ 0.5 MPa
8
6
CPM
Center
L
4
2
10
Charge removal time (sec.)
10
− ER-X064
− ER-X048
− ER-X032
− ER-X016
Charge removal time (sec.)
Air flow [ℓ/min. (ANR)]
400
Charge removal time (sec.)
Air flow
300
8
6
PRESSURE /
FLOW
SENSORS
L
4
INDUCTIVE
PROXIMITY
SENSORS
2
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
0
LIGHT
CURTAINS /
SAFETY
COMPONENTS
CPM
Center
0
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
L
−
W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
Center
L
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
CPM
+
−
W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937 Center
0
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
+
L
−
W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
Charge removal field
(vertical direction, 0.005 MPa, 50 Hz)
Charge removal width W (mm in)
Center
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
Charge removal field
(vertical direction, airless, 1 Hz)
Charge removal width W (mm in)
CPM
+
Charge removal field
(vertical direction, airless, 10 Hz)
Charge removal width W (mm in)
Charge removal width W (mm in)
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
CPM
+
Center
−
L
W
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
PLC
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
+
L
−
W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
+
Center
L
−
W
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
Charge removal field
(vertical direction, 0.5 MPa, 10 Hz)
Charge removal width W (mm in)
−
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937 Center
0
Charge removal field
(vertical direction, 0.5 MPa, 50 Hz)
Charge removal width W (mm in)
L
W
Charge removal width W (mm in)
CPM
+
Center
Charge removal field
(vertical direction, 0.005 MPa, 1 Hz)
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
+
Center
L
−
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
−
W
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
Static
Removers
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
ER-X
CPM
Center
+
L
− W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
Center
+
L
− W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
Charge removal width W (mm in)
CPM
+
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
UV
CURING
SYSTEMS
Selection
Guide
Charge removal field
Charge removal field
Charge removal field
(horizontal direction, airless, 50 Hz) (horizontal direction, airless, 10 Hz) (horizontal direction, airless, 1 Hz)
Charge removal width W (mm in)
Charge removal field
(vertical direction, 0.5 MPa, 1 Hz)
MACHINE
VISION
SYSTEMS
W
ER-X032
Common
Charge removal width W (mm in)
Charge removal width W (mm in)
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
Charge removal width W (mm in)
WIRE-SAVING
SYSTEMS
FA
COMPONENTS
Charge removal field
(vertical direction, 0.005 MPa, 10 Hz)
L
SENSOR
OPTIONS
MEASUREMENT
SENSORS
Common
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
PARTICULAR
USE
SENSORS
SIMPLE
WIRE-SAVING
UNITS
Charge removal field
(vertical direction, airless, 50 Hz)
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937 Center
0
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
─ Airless
─ 0.005 MPa
─ 0.1 MPa
─ 0.3 MPa
─ 0.5 MPa
Common
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
FIBER
SENSORS
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
ER-TF
ER-VS02
ER-VW
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
CPM
Center
+
−100
−3.937
L
− W
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
ER-Q
ER-F
1167
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Cleaning
Box
Pulse
Air-gun
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
ER-VS02
ER-VW
ER-Q
ER-F
Charge removal width W (mm in)
Charge removal width W (mm in)
CPM
+
L
− W
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
Charge removal field
(horizontal direction, 0.5 MPa, 1 Hz)
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937 Center
0
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
+
L
− W
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
Charge removal field
(horizontal direction, airless, 50 Hz)
800
31.496
600
23.622
400
15.748
200
7.874
0
Center
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
CPM
+
L
− W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
Charge removal field
(horizontal direction, airless, 10 Hz)
800
31.496
600
23.622
400
15.748
200
7.874
0
Center
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
CPM
+
L
− W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
ER-X064
800
31.496
600
23.622
400
15.748
200
7.874 Center
0
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
CPM
+
L
− W
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
100
200
300
400
500
600
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
Charge removal field
(horizontal direction, 0.005 MPa, 50 Hz)
800
31.496
600
23.622
400
15.748
200
7.874
0
Center
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
CPM
+
L
− W
− 1 sec.
− 2 sec.
− 5 sec.
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
Charge removal field
(horizontal direction, 0.005 MPa, 10 Hz)
800
31.496
600
23.622
400
15.748
200
7.874
0
Center
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
CPM
+
L
− W
− 1 sec.
− 2 sec.
− 5 sec.
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
ER-X064
800
31.496
600
23.622
400
15.748
200
7.874
0
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
Charge removal field
(horizontal direction, 0.005 MPa, 1 Hz)
800
31.496
600
23.622
400
15.748
200
7.874
0
Center
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
CPM
+
L
− W
− 1 sec.
− 2 sec.
− 5 sec.
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
ER-X008
Charge removal field
(horizontal direction, 0.5 MPa, 50 Hz)
Charge removal width W (mm in)
ER-TF
CPM
+
L
− W
Charge removal field
(horizontal direction, airless, 1 Hz)
Electrostatic
Sensor
ER-X
Center
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
Charge removal width W (mm in)
PLC
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
Center
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
Charge removal width W (mm in)
LASER
MARKERS
200
400
600
800
1,000
7.874 15.748 23.622 31.496 39.370
Charge removal distance L (mm in)
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
+
L
− W
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
Center
CPM
+
L
− W
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
Charge removal field
(horizontal direction, 0.5 MPa, 10 Hz)
800
31.496
600
23.622
400
15.748
200
7.874
0
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
Center
CPM
+
L
− W
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
Charge removal field
(horizontal direction, 0.5 MPa, 1 Hz)
800
31.496
600
23.622
400
15.748
200
7.874 Center
0
−200
−7.874
−400
−15.748
−600
−23.622
−800
−31.496 0
Charge removal field
(horizontal direction, 0.005 MPa, 10 Hz)
300
11.811
CPM
+
L
− W
Charge removal width W (mm in)
STATIC
ELECTRICITY
PREVENTION
DEVICES
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937 Center
0
Charge removal field
(horizontal direction, 0.5 MPa, 50 Hz)
ER-X064
Charge removal field
(horizontal direction, 0.5 MPa, 10 Hz)
Charge removal width W (mm in)
MEASUREMENT
SENSORS
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
+
L
− W
ER-X032
Charge removal width W (mm in)
WIRE-SAVING
SYSTEMS
Center
Charge removal width W (mm in)
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
Charge removal width W (mm in)
PARTICULAR
USE
SENSORS
−100
−3.937
−200
−7.874
−300
−11.811
−400
−15.748
−500
−19.685 0
CPM
+
L
− W
Charge removal field
(horizontal direction, 0.005 MPa, 1 Hz)
Charge removal width W (mm in)
INDUCTIVE
PROXIMITY
SENSORS
Center
Charge removal width W (mm in)
PRESSURE /
FLOW
SENSORS
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
Charge removal width W (mm in)
LIGHT
CURTAINS /
SAFETY
COMPONENTS
Charge removal field
Charge removal field
(horizontal direction, 0.005 MPa, 50 Hz) (horizontal direction, 0.005 MPa, 10 Hz)
Charge removal width W (mm in)
AREA
SENSORS
ER-X032
Charge removal width W (mm in)
MICRO
PHOTOELECTRIC
SENSORS
Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM)
Charge removal width W (mm in)
PHOTOELECTRIC
SENSORS
ER-X SERIES
CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Please contact our office for details on data that is not listed here.
FIBER
SENSORS
LASER
SENSORS
Area Ionizer
Center
200
7.874
100
3.937
0
−100
−3.937
− 0.5 sec.
− 1 sec.
− 2 sec.
200 400 600 800 1,000 1,200 1,400 1,600
7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992
Charge removal distance L (mm in)
CPM
+
L
− W
−200
−7.874
−300
−11.811 0
− 1 sec.
− 2 sec.
− 5 sec.
− 10 sec.
300
400
600
100
500
200
3.937 7.874 11.811 15.748 19.685 23.622
Charge removal distance L (mm in)
Area Ionizer
ER-X SERIES
1168
I/O CIRCUIT AND WIRING DIAGRAMS
When connecting the output to negative common
6
2
3
4
5
6
7
8
9
10
(Front view)
Housing: 5569-10A
[Manufactured by Molex]
Terminal
No.
Terminal
name
3
8
1
Color
code
1
0V
Blue
2
–
4
COM(–)
Discharge
control input
COM(OUT)
Violet
5
F.G. terminal
Green/Yellow
6
24 V
Brown
7
COM(+)
–
8
COM(IN)
White
9
Alarm output
Orange
10
Error output
Black
3
10
Pink
Note: C
olor code refers to cable colors
of an optional power supply
cable.
(Brown) +V
6
7 COM(+)
(White) COM (IN)
8
(Pink) Discharge control input
3
(Brown) +V
7 COM(+)
(Violet) COM (OUT)
4
(Orange) Alarm output
Load
9
Main circuit
1
When connecting the output to positive common
*1
(Black) Error output
Load
(Pink) Discharge control input
+
24 V DC
–
±10 %
(White) COM (IN)
Main circuit
Power connector pin arrangement
FIBER
SENSORS
9
10
(Blue) 0 V
4
2 COM(─)
5
Internal circuit
(Green/Yellow) F.G.
PHOTOELECTRIC
SENSORS
*2
(Orange) Alarm output
Load
(Black) Error output
+
–
24 V DC
±10 %
(Blue) 0 V
1
2 COM(–)
Be sure to ground.
5
User’s circuit
(Green/Yellow) F.G.
Internal circuit
*1
Be sure to ground.
SENSOR
OPTIONS
or
or
Contact “closed” or transistor ON: Discharge halt
Contact “open” or transistor OFF: Starting discharge
Contact “closed” or transistor ON: Discharge halt
Contact “open” or transistor OFF: Starting discharge
SIMPLE
WIRE-SAVING
UNITS
Notes: 1) Be sure to ground the F.G. terminal. If F.G. terminal is not connected properly, it may cause electric shock.
2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF
(open) the discharge control input. Discharge will start in 20 ms.
• Never use this product in a device for personnel protection.
• In case of using devices for personnel protection, use
products which meet laws or standards, such as OSHA, ANSI
or IEC etc., for personnel protection applicable in each region
or country.
• Do not use this product in places where there may be a
danger of flammable or combustible items being present.
• To prevent electric shock and to conduct proper discharge, be
sure to ground a frame ground (F.G.) terminal of a controller.
• Do not place hands near the discharge needle. Doing so may
cause electric shock.
• Since the tip of the discharge needle is sharp, take sufficient
care in handling the discharge needle, or injuries may result.
• The high-voltage cable between the head and the highvoltage unit must be fixed and the minimum bend radius is
R30 mm R1.181 in or more. In case of using at the bend
radius R30 mm R1.181 in or less and using at moving part
may cause fire and break down, etc. of the high-voltage
cable.
• Clean the discharge needle regularly (about once a week).
Otherwise, optimum charge removal performance may not be
achieved, and accidents or operating problems may occur.
• If this product is used in a confined space, ozone emitted
from this product may be detrimental. Be sure to provide
ventilation.
• Do not direct ionized air toward the face. Ozone may cause
irritation to places such as the nose and throat.
Mounting
Head installation
• Using 2 M4 screws or 1 M6 screw,
mount the head onto the equipment
housing.
• Loosen the angle adjustment screw,
adjust the head angle, and then
fasten the head with the tightening
torque of 0.5 N∙m or less.
Angle adjustment screw
M4 screw
Angle adjustment screw
M6 screw
PRESSURE /
FLOW
SENSORS
PARTICULAR
USE
SENSORS
Non-voltage contact or
NPN transistor/open collector
PRECAUTIONS FOR PROPER USE
AREA
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
User’s circuit
*2
Non-voltage contact or
PNP transistor/open collector
MICRO
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
Load
(Violet) COM (OUT)
LASER
SENSORS
Refer to p.1501 for general precautions.
Notes: 1) Be sure to ground the equipment housing onto which the head is
mounted.
2) The distance between the head and the charge removing object
should be 30 mm 1.181 in or more.
If the static buildup of the charge removing object is 30 kV or
more, set the distance to 50 mm 1.969 in or more.
3) If there is metal near the head or between the head and the charge
removing object, ion is absorbed, hindering appropriate static
removal. Install the head under the following installation condition.
4) In case using the side mounting, the discharge frequency should
be 10 Hz or more.
• Back-side mounting (All frequencies) • Side mounting (10 Hz or more)
50 mm 1.969 in or more
50 mm 1.969 in or more
Surrounding metal
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
The discharge muzzle
must exceed this line
(surrounding metal.)
5) When installing two or more heads set the same frequency and
keep the distance as below. In face to face or parallel using
different frequency, keep the distance between the heads 400 mm
15.748 in or more.
• Face-to-face installation
• Parallel installation
Selection
Guide
Static
Removers
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
100 mm
3.937 in
or more
ER-X
ER-TF
50 mm 1.969 in or more
ER-VS02
High-voltage unit installation
• Use 2 M4 screws or 2 M6 screws to
fasten the head. The tightening torques
for fastening, are as follows.
When using M4 screws: 1.2 N·m
When using M6 screws: 2.5 N·m
M6 screw
M4 screw
Notes: 1) Do not place any objects on top of the highvoltage unit.
2) When using multiple heads, keep the
distance of at least 10 mm 0.394 in
10 mm
between the high-voltage units.
0.394 in
3) W
hen fastening the high-voltage unit
or more
using M6 screws, fasten
before connecting the head connection cable.
ER-VW
ER-Q
ER-F
1169
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Area Ionizer
ER-X SERIES
PRECAUTIONS FOR PROPER USE
Refer to p.1501 for general precautions.
PIPING
Controller installation
• Air supplied to this product will reduce contamination of
the discharge needle and improve the charge removal
speed.
• The outer diameter of the air tube to fit to the air inlet
portion of this product should be ø6 mm ø0.236 in.
• Make sure that clean air (air containing no water, no oil
and no dust) should be supplied.
• Since the pressure will drop when the air piping from
the main pressure supply is extended or pneumatic
components (e.g., needle valve, speed controller, mini
filter) are added, keep an eye on the pressure supply
to the ionizer making sure it is not in short supply.
For the pneumatic components, select those that can
accommodate the air supply flow rate.
• Mount the controller on a 35 mm 1.378 in wide DIN rail or
using M4 screws.
Lock release
lever
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
2
1
35 mm 1.378 in wide
DIN rail
• Pull the lock release lever to remove this product from the
DIN rail.
M4 screw
SIMPLE
WIRE-SAVING
UNITS
Head section
Air inlet
WIRE-SAVING
SYSTEMS
ø6 mm ø0.236 in tube
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
11.4 mm 0.449 in
Note: After inserting the tube into the joint of this product, always make sure
that the tube is all the way in and securely inserted.
Insufficient tube insertion will cause air leakage.
• The tightening torque should be 1.2 N•m or less.
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from our website.
ER-X008
Head
ø6.9 ø0.272 high-voltage cable 500 mm 19.685 in long
UV
CURING
SYSTEMS
2-ø6.5 ø0.256
mounting holes
6 0.236
180 7.087
17 0.669
160 6.299
28.5
1.122
9.4 0.370
Joint for ø6 ø0.236 air tube
28.5
1.122 9.4
0.370
106 4.173
40
40
1.575
1.575
28 1.102
18 0.709
Selection
Guide
5 0.197
Static
Removers
2-ø4.5 ø0.177
mounting holes
Cleaning
Box
Electrostatic
Sensor
38
1.496
(18)
(0.709)
ER-X
35 1.378
10.5 0.413
170 6.693
ER-Q
ER-F
9.5 0.374
Points of discharge
needle ion air outlet
163 6.417
ø12 ø0.472
150 5.906
138 5.433
162 6.378
22
0.866
4.2 0.165
30
1.181
(25) (0.984)
9.4
0.370
ER-VS02
ER-VW
Clean air outlet
(4 points)
2-ø6.5 ø0.256
Pulse
Air-gun
ER-TF
31 1.220
192 7.559
6.2
0.2441
6
0.236 18 0.709
Head mounting bracket
28.4 1.118
18
0.709
Discharge needle unit
Area Ionizer
DIMENSIONS (Unit: mm in)
ER-X016
ER-X032
35
1.378
ER-X064
2-ø4.5 ø0.177
mounting holes
10.5
0.413
31
1.220
162 6.378
28.4
1.118
40
1.575
6
0.236
192 7.559
4.2
0.165
18
0.709
6.2
0.244
9.4
0.370
A
40
1.575
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
D
C
22
0.866
30 1.181
18
0.709
Head mounting bracket
Discharge needle unit
Model No.
A
B
C
D
(E)
ER-X016
120 4.724
194 7.638
226 8.898
238 9.370
251 9.882
ER-X032
280 11.024
354 13.937
386 15.197
398 15.669
411 16.181
ER-X048
440 17.323
514 20.236
546 21.496
558 21.969
571 22.480
ER-X064
600 23.622
674 26.535
706 27.795
718 28.268
731 28.780
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
Mounting drawing with discharge part protective cover (ER-XACVR)
(18)
(0.709)
Model No.
45.7
1.799
15.7 0.618
159.6 6.283
(160) (6.299)
(F)
LASER
SENSORS
AREA
SENSORS
Head mounting bracket
Discharge part protective cover
FIBER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Clean air outlet (4 points)
4.2
0.165
9.4
0.370
28.5
1.122
B
(E)
2-ø6.5
ø0.256
18
ø12
0.709
ø0.472
170 6.693
Joint for ø6 ø0.236 air tube
9.5 0.374
Points of discharge
needle ion air outlet
Details of a head mounting bracket
ø6.5
ø0.256
28.5
1.122
9.4
0.370
160 6.299
(25)
(0.984)
9.4 0.370
Head
180 7.087
5 0.197
(18)
(0.709)
The CAD data in the dimensions can be downloaded from our website.
ø6.9 ø0.272 high-voltage cable 500 mm
19.685 in long
6
0.236
2-ø6.5 ø0.256 17
mounting holes 0.669
28
1.102 18
0.709
38
1.496
ER-X048
1170
ER-X SERIES
18
0.709
25.4
1.000
(F)
ER-X016
159.6 6.283
ER-X032
319.6 12.583
ER-X048
479.6 18.882
ER-X064
639.6 25.181
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
ER-XC02
Controller
ER-XCCJ□H
(16)
(0.630) (16)
(0.630)
(ø6)
(9.1)
(0.358) (ø0.236)
For head 1
Head connection connector
S12B-PUDSS-1 [Manufactured by JST Mfg.Co., Ltd.]
(9.3)
(0.336)
5.2
0.205
6.5
0.256 7
0.276
7
0.276
L
• Length L
(9.1) (0.358)
(14)
(0.551)
For head 2
44
1.732
Head connection cable
(14)
(0.551)
(8.8)
(0.346)
(8.8)
(0.346)
Model No.
Length L
ER-XCCJ2H
2,000
78.740
ER-XCCJ5H
5,000
196.850
ER-XCCJ10H
10,000
393.701
18
0.709
53 2.087
39 1.535
10
0.394
ER-XCC□
Power cable (Optional)
Suitable for 35 mm 1.378 in width DIN rail
(103.5) (4.075)
76
97 2.992
3.189
(19.6)
(0.772)
Selection
Guide
(140)
(5.512)
(14.4)
(0.567)
ER-XAPS(-EX)
Model No.
Length L
ER-XCC2
2,000
78.740
ER-XCC5
5,000
196.850
AC adapter (Optional)
F.G. wire 3.7 m 12.139 ft
4
0.157
(14.4)
(0.567)
2-ø5 ø0.197 mounting holes
Power supply connection connector
5569-10A [Manufactured by Molex]
(22.2)
(0.874)
Cable
1.8 m
5.910 ft
(19.6) (0.772)
95.9
3.776
28 1.102
43.8
1.724
Note: The AC cable is not enclosed with ER-XAPS-EX.
Cleaning
Box
Pulse
Air-gun
• Length L
L
(ø5.3) (ø0.209)
(22.2)
(0.874)
35.4
1.394 90
3.543
(23.2)
(0.913)
UV
CURING
SYSTEMS
Static
Removers
27.3
1.075
60
2.362
(16.5)
(0.650)
9.2 0.362
MACHINE
VISION
SYSTEMS
AC cable 1.8 m
5.910 ft (Note)
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F