EX-F1-C5

EX-F1-C5

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR LIQUID DETECT 12-24V NPN

  • 数据手册
  • 价格&库存
EX-F1-C5 数据手册
Pipe-mountable Liquid Level Detection Sensor Other Products FT-Z8Y Chemical-resistant FD-F4/F9 FD-F8Y EX-F1 Liquid Leak / Liquid Level Sensing SENSORS FOR SEMICONDUCTOR INDUSTRY EX-F1 SERIES Amplifier Built-in Reliable liquid level detection with amplifier built-in low-priced sensor Conforming to EMC Directive Space-saving amplifier built-in type Low price Easily mountable and adjustable EX-F1 amplifier built-in sensor saves space as there is no need to install a separate amplifier. EX-F1 is very cost-effective. Just attach it on a pipe with the tying bands. The position can be easily changed with the release lever even after mounting, so that there is no need to cut the tying bands. Release lever Position adjustable Easy to check operation Indicator Operation mode switch The operation can be checked at a glance from different directions. Either Light-ON or Dark-ON can be selected by a switch. This is useful to check the operation during installation because it forces the output to be turned ON or OFF even without the liquid being inside the pipe. Operation indicator (Red) Lights up when the output is ON. ( ) 608 Detecting liquid level in a tank Principle of Detection When the pipe is empty, the beam is reflected from the inner surface of the pipe wall and returns to the beamreceiving part, since the difference in the refractive indexes of the pipe and air is large. When there is liquid in the pipe, the beam enters the liquid through the wall and does not return to the beamreceiving part, since the difference in the refractive indexes of the pipe and the liquid is small. EX-F1 The beam passes through the wall into the liquid. Chemical-resistant FT-Z8Y The beam reflected from the inner surface of the pipe wall returns to the beam-receiving part. ORDER GUIDE Appearance Sensing object Applicable pipe diameter Outer dia."6 to "13 mm "0.236 to "0.512 in Liquid (Note 1)   PFA (Fluorine resin) or  equivalently transparent    pipe, wall thickness 1 mm    0.039 in   (Note 2) Model No. Other Products Amplifier Built-in Pipe-mountable 5 m 16.404 ft cable length type Type SENSORS FOR SEMICONDUCTOR INDUSTRY APPLICATIONS Liquid Leak / Liquid Level Sensing FD-F4/F9 FD-F8Y EX-F1 EX-F1 EX-F1 EX-F1-C5 Notes: 1) Unclear or highly viscous liquid may not be detected stably. 2) Do not use the sensor with pipes other than the above specified. 609 SENSORS FOR SEMICONDUCTOR INDUSTRY EX-F1 SPECIFICATIONS Amplifier built-in • Pipe-mountable Type Item Model No. EX-F1 FD-F4/F9 FD-F8Y EX-F1 Liquid Leak / Liquid Level Sensing Sensing object Liquid (Note 1) Outer dia. "6 to "13 mm "0.236 to "0.512 in transparent pipe [PFA (Fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in ] (Note 2) Applicable pipe diameter Repeatability 0.5 mm 0.020 in or less 12 to 24 V DC10 % Ripple P-P 10 % or less Supply voltage Current consumption 30 mA or less NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) Output Utilization category DC-12 or DC-13 Output operation Switchable either Light-ON (Liquid-absent-ON) or Dark-ON (Liquid-present-ON) Short-circuit protection Incorporated Response time 2 ms or less Red LED (lights up when the output is ON) Pollution degree 3 (Industrial environment) Environmental resistance Ambient temperature (Note 3) 10 to55 C 14 to131 F (No dew condensation or icing allowed), Storage:20 to70 C 4 to158 F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Sunlight: 10,000 #x at the light-receiving face, lncandescent light: 3,000 #x at the light-receiving face Ambient illuminance EMC EN 50081-2, EN 50082-2, EN 60947-5-2 Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each Emitting element Infrared LED (modulated) Material Enclosure: Polycarbonate, Tying band: Nylon, Anti-slip tube: Silicone 0.1 mm2 3-core cabtyre cable, 1 m 3.281 ft long Cable Cable extension Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. Weight 15 g approx. Accessories Tying band: 2 pcs., Anti-slip tube: 2 pcs. Notes: 1) Unclear or highly viscous liquid may not be detected stably. 2) Do not use the sensor with pipes other than the above specified. 3) Liquid being detected should also be kept within the rated ambient temperature range. I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Wiring diagram Color code D Sensor circuit Other Products FT-Z8Y Chemical-resistant Operation indicator (Brown) V ZD Brown Load (Black) Output 100 mA max.   Tr (Blue) 0 V Internal circuit Users’ circuit Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor 610 Load 12 to 24 V DC 10 % Black Blue   12 to 24 V DC 10 % Mounting • Mount the sensor on a pipe with the attached tying bands and anti-slip tubes as shown in the figure below. Make sure that the release lever is retracted (position as in the figure) before mounting. Fasten two tying bands, as shown, and cut off the excess portions. Anti-slip tube Upper side Tying band Selecting output operation • Either Light-ON (Liquidabsent-ON) or Dark-ON (Liquid-present-ON) can be selected with the operation mode switch according to your application. Operation indicator (Red) Lights up when the output is ON Operation mode switch L: Light-ON (Liquid-absent-ON) D: Dark-ON (Liquid-present-ON) • The indicator operation and the output operation change with the setting of the operation mode switch as given in the table below. Lower side Release lever • If other tying bands are to be used, the dimension @ shown in the figure below should be 2.5 mm 0.098 in or less. @ Liquid-absent Liquid-present : Lights up Position adjustment • After it is mounted on the pipe with tying bands, the sensor position can be easily adjusted. MODE ( Light-ON Liquid-absentON ( Dark-ON Liquid-presentON Adjustment 1 Unlock the release lever (in the direction of the arrow). Release lever 2 Press the movable center holders forward to loosen the tying bands and adjust the position. Position adjustable Loosen Press 3 Lock the release lever to its original place. Release lever Note: The lever mechanism must be used only to adjust the position, and not for tightening the tying bands. If tying bands are tightened while the lever is open, and then the lever is locked, the sensor may be damaged. DIMENSIONS (Unit: mm in) : Lights off Sensing condition Operation indicator Output operation ) ) Liquid-present OFF Liquid-absent ON Liquid-present ON Liquid-absent OFF Others • Do not use during the initial transient time (50 ms) after the power supply is switched on. • Do not use this sensor with a pipe which is not transparent. • Unclear or highly viscous liquid may not be detected. • Fit the sensor to the pipe securely, otherwise the operation may be erroneous. Outer Inner wall wall • Take care that no dew condenses Liquid drops on the pipe’s sensing surface or the pipe’s inside wall and that no bubble attaches on the pipe’s inside wall, since it can affect the operation. Bubbles • If a liquid drop flows down across the sensing point or an air bubble sticks on the wall at the sensing point, the operation may be erroneous. Make sure that no bubble arises in the liquid, and that no dew or liquid drop is present on either surface of the pipe wall. • EX-F1 is not water-proof or chemical-resistant. Installation should be avoided at any place where it could come in direct contact with water or chemicals. The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/ Beam axis 13 0.512 8 0.315 27 1.063 13 0.512 Beam axis 23 29 0.906 1.142 Operation mode switch Operation indicator (Red) "2.5 "0.098 cable,1 m 3.281 ft long 4 0.157 15 0.591 611 SENSORS FOR SEMICONDUCTOR INDUSTRY This product is not a safety sensor. Its use is not intended or designed to protect life and prevent body injury or property damage from dangerous parts of machinery. It is a normal object detection sensor. Liquid Leak / Liquid Level Sensing FD-F4/F9 FD-F8Y EX-F1 Refer to p.1135l for general precautions. Chemical-resistant FT-Z8Y PRECAUTIONS FOR PROPER USE Other Products EX-F1
EX-F1-C5 价格&库存

很抱歉,暂时无法提供与“EX-F1-C5”相匹配的价格&库存,您可以联系我们找货

免费人工找货
EX-F1-C5
  •  国内价格 香港价格
  • 1+1660.885881+214.66818

库存:6