FD-F41

FD-F41

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR REFLECTIVE LIQ LEV 6-26MM

  • 数据手册
  • 价格&库存
FD-F41 数据手册
Pipe-mountable Liquid Level Detection Fiber Other Products FT-Z8Y Chemical-resistant FD-F4/F9 FD-F8Y EX-F1 Liquid Leak / Liquid Level Sensing SENSORS FOR SEMICONDUCTOR INDUSTRY FD-F4/F9 Reliable liquid level detection from outside the pipe Widely applicable FD-F41/F91 released Easily mountable and adjustable Durable up to 100 C 212 F FD-F41/F91 can reliably detect the liquid level inside a pipe made of, not only, PVC, but also, acrylic or glass. The range of applicable pipes has been increased by this addition to FD-F4/F9 (for 1 mm 0.039 in thick PFA pipe). Just attach it on a pipe with the tying bands. The position can be easily changed with the release lever even after mounting, so that there is no need to cut tying bands. FD-F4 /F9 can operate under an ambient temperature of 40 to 100 C 40 to  212  F. Hence, even hot liquids can be safely detected. Release lever Position adjustable Applicable pipe "6 to "26 mm "0.236 to "1.024 in Compact body FD-F4/F9 can be mounted on a wide range of pipe diameters from "6 to "26 mm "0.236 to "1.024 in. The body is just 13 mm 0.512 in thick so that multi-level detection by adjacent mounting at 13 mm 0.512 in pitch is possible. 5 m 16.404 ft fiber cable length type is available FD-F9 is attached with a 5 m 16.404 ft long fiber cable. Hence, even if it is used in an explosive area, the amplifier can be installed outside the explosive area. Principle of detection When the pipe is empty, the beam is reflected from the inner surface of the pipe wall and returns to the beam-receiving part, since the difference in the refractive indexes of the pipe and air is large. When there is liquid in the pipe, the beam enters the liquid through the wall and does not return to the beam-receiving part, since the difference in the refractive indexes of the pipe and the liquid is small. The beam reflected from the inner surface of the pipe wall returns to the beam-receiving part. 612 The beam passes through the wall into the liquid. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com APPLICATIONS Detecting liquid level in a tank SENSORS FOR SEMICONDUCTOR INDUSTRY FD-F4/F9 Liquid Leak / Liquid Level Sensing FD-F4/F9 FD-F8Y EX-F1 FD-F41 ORDER GUIDE Fibers Outer dia "6 to "26 mm "0.236 to "1.024 in transparent pipe PVC, fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in For PFA pipe, wall thickness 1mm 0.039 in Liquid (Note 1) Fiber cable length Allowable bending : radius Free-cut FD-F41 2m 6.562 ft 5m 16.404 ft Model No. Chemical-resistant FT-Z8Y Sensing object Applicable pipe diameter (Note 2) FD-F91 R10 mm R0.394 in Outer dia "6 to "26 mm "0.236 to "1.024 in transparent pipe 2m 6.562 ft FD-F4 PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in 5m 16.404 ft FD-F9 Other Products Appearance Standard Type Notes: 1) Unclear or highly viscous liquid may not be detected stably. Notes: 2) Liquid in an opaque pipe cannot be detected correctly. Amplifiers Appearance Model No. Emitting element Output FX-301 NPN open-collector transistor FX-301P PNP open-collector transistor FX-302 NPN open-collector transistor FX-302P PNP open-collector transistor High-functional digital Digital Type Quick-connection cable is not supplied with the amplifier. Please order it separately. High speed digital NPN open-collector transistor FX-303P PNP open-collector transistor Manually set Red LED FX-303 FX-311 NPN open-collector transistor FX-311P PNP open-collector transistor Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 613 SENSORS FOR SEMICONDUCTOR INDUSTRY FD-F4/F9 ORDER GUIDE Quick-connection cables Quick-connection cable is not supplied with the amplifier. Please order it separately. Main cable Main cable Sub cable Model No. Description CN-73-C1 Length: 1 m 3.281 ft CN-73-C2 Length: 2 m 6.562 ft CN-73-C5 Length: 5 m 16.404 ft CN-71-C1 Length: 1 m 3.281 ft CN-71-C2 Length: 2 m 6.562 ft CN-71-C5 Length: 5 m 16.404 ft End plates • CN-73-C1 • CN-73-C2 • CN-73-C5 0.15 mm2 3-core cabtyre cable, with connector on one end Cable outer diameter: "3.0 mm "0.118 in. Sub cable • CN-71-C1 • CN-71-C2 • CN-71-C5 0.15 mm2 1-core cabtyre cable, with connector on one end Cable outer diameter: "3.0 mm "0.118 in. End plates are not supplied with the amplifier. Please order it separately when the amplifiers are mounted in cascade. Appearance Other Products FT-Z8Y Chemical-resistant FD-F4/F9 FD-F8Y EX-F1 Liquid Leak / Liquid Level Sensing Type Model No. MS-DIN-E Description When cascading multiple amplifiers, or when it moves depending on the way it is installed on a DIN rail, these end plates ensure that all amplifiers are mounted together in a secure and fully connected manner. Two pcs. per set Accessories • FX-CT2 (Fiber cutter) 614 • MS-DIN-2 (Amplifier mounting bracket) • FX-AT4 ("1 mm "0.039 in fiber attachment) Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com SPECIFICATIONS Refer to p.77/p.119/p.138/p.166 for amplifier specifications. Fibers For PFA pipe, wall thickness 1 mm 0.039 in FD-F41 Model No. FD-F91 Applicable amplifiers FD-F4 FD-F9 FX-301(P), FX-302(P), FX-303(P), FX-311(P) Sensing object Liquid (Note 1) Outer dia "6 to "26 mm "0.236 to "1.024 in transparent pipe Outer dia "6 to "26 mm "0.236 to "1.024 in transparent pipe Applicable pipe diameter (Note 2) (PVC, fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in) [PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in] Repeatability 1 mm 0.039 in or less (for water) Allowable bending radius R10 mm R0.394 in or more Fiber cable length 2 m 6.562 ft free-cut 5 m 16.404 ft free-cut 2 m 6.562 ft free-cut 5 m 16.404 ft free-cut 40 to100 C 40 to212 F (No dew condensation or icing allowed), Storage:40 to100 C 40 to212 F Ambient temperature (Note 3) Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Material Fiber head: Polyetherimide, Fiber core: Acrylic, Fiber sheath: Polypropylene, Tying band: Nylon, Anti-slip tube: Silicone Weight 6 g approx. 11 g approx. 6 g approx. 11 g approx. Chemical-resistant FT-Z8Y Tying band: 4 pcs. Anti-slip tube: 2 pcs. FX-CT2 (Fiber cutter): 1 pc. FX-AT4 ("1 mm "0.0.39 in fiber attachment): 1set (Note 4) Accessories Notes: 1) Unclear or highly viscous liquid may not be detected stably. Notes: 2) Liquid in an opaque pipe cannot be detected correctly. Notes: 3) Liquid being detected should also be kept within the rated ambient temperature range. Notes: 4) Fiber attachments provided include FX-AT4, made for the FX-301/302/303/311 series, and conventional amplifier attachments. PRECAUTIONS FOR PROPER USE Refer to p.1135l for general precautions and p.90/p.121/p.141/p.168l for amplifier precautions. This product is not a safety sensor. Its use is not intended or designed to protect life and prevent body injury or property damage from dangerous parts of machinery. It is a normal object detection sensor. Mounting • Mount the fiber on a pipe with the attached tying bands and anti-slip tubes as shown in the figure below. Make sure that the release lever is retracted (position as shown in the figure) before mounting. Fasten two tying bands, as shown, and cut off the excess portions. Position adjustment • In case of mounting on the pipe with tying bands, the fiber position can be easily adjusted. Adjustment Release lever 1 Unlock the release lever (in the direction of the arrow). Loosen 2 Press the movable center holders forward to loosen the tying bands and adjust the position. Position adjustable Press 3 Lock the release lever to its original place. Anti-slip tube Upper side Release lever Tying band Lower side Release lever 2-"3.2 mm 0.126 in mounting holes • If other tying bands are to be used, the dimension @ shown in the figure below should be 2.5 mm 0.098 in or less. Notes: 1) Whenever the mounting position is changed, adjust the sensitivity again. Notes: 2) The lever mechanism must be used only to adjust the position, and not for tightening the tying bands. If tying bands are tightened while the lever is open, and then the lever is locked, the fiber may be damaged. @ • In case of mounting using the two mounting holes, use M3 screws, plain washers, and spring washers. The tightening torque should be 0.5 N m or less. Please arrange the M3 screws, plain washers, and spring washers separately. ( Liquid Leak / Liquid Level Sensing FD-F4/F9 FD-F8Y EX-F1 Item Standard 2 m 6.562 ft fiber cable length 5 m 16.404 ft fiber cable length 2 m 6.562 ft fiber cable length 5 m 16.404 ft fiber cable length ) Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 615 Other Products Type SENSORS FOR SEMICONDUCTOR INDUSTRY FD-F4/F9 SENSORS FOR SEMICONDUCTOR INDUSTRY FD-F4/F9 FD-F8Y EX-F1 Liquid Leak / Liquid Level Sensing FD-F4/F9 PRECAUTIONS FOR PROPER USE Refer to p.1135l for general precautions and p.90/p.121/p.141/p.168l for amplifier precautions. Fiber attachment (FX-AT4) • When the beam-emitting and beam-receiving fibers are inserted into the fiber sensor amplifier (FX-301/302/303/311 series etc.), the enclosed fiber attachment for FX-301/302/303/311 series facilitates insertion of the fibers and reduces the possibility of incorrect fiber insertion. For conventional amplifier 1 Thread the fiber cable through the gland and holder separately, and screw the gland into the holder clockwise. Screw it clockwise Cautions • Take care that fiber attachment for FX-301/302/303/311 series cannot be used with fiber sensor amplifiers having a pitch, between the beam-emitting and the beam-receiving fibers, other than 7 mm 0.276 in. In case of fiber sensor amplifiers having a pitch other than 7 mm 0.276 in, please use attachments for conventional amplifier. 7.0 mm 0.276 in 2 Insert the fiber cables one by one into the holes for "1.0 mm "0.039 in or "1.3 mm "0.051 in fiber cable of the fiber cutter (FX-CT2) from the direction shown in the figure below. ( At this time, insert the attachment to a position at which it stops. The fiber cables will be cut at a position approx. 0.5 mm 0.020 in from the holder. ( Mounting of fiber attachments For FX-301/302/303/311 series Other Products FT-Z8Y Chemical-resistant 1 Mount the holders on the gland lightly Holder For "1.0 mm "0.039 in or "1.3 mm "0.051 in fiber cables Gland Note: If both long holders and short holders are enclosed with the fiber, use the short holders. 2 Insert the fiber cables into the holders, in condition 1. 3 Tighten the holders to fix the fiber cables at the desired length. 4 Insert the fiber cables, in condition 3, into the holes for "1.0 mm "0.039 in or "1.3 mm "0.051 in fiber cables of the fiber cutter (FX-CT2) from direction shown in the figure below. Holder Gland For "1.0 mm "0.039 in or "1.3 mm "0.051 in fiber cables 5 Cut both fiber cables simultaneously. (At this time, insert the attachment to a position at which it stops. The fiber cables will be cut at a position approx. 0.5 mm 0.020 in from the holder.) 6 After cutting, insert the fiber cables to the fiber sensor amplifier immediately. 616 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com Cutting procedure • To cut the fiber cables, insert them from the direction shown below. (Fiber cable insertion direction) Free-cut fiber without FX-AT attachment Free-cut fiber with FX-AT attachment How to use fiber cutter (FX-CT2) 1 Slide part @ of the fiber cutter fully upward till it stops. 2 Insert the fiber cables, mounted in the attachment, till they stop. Take care that there are separate fiber cable insertion holes for "2.2 mm "0.087 in and "1.0 mm "0.039 in or "1.3 mm "0.051 in fiber cables. 3 Slide part @ of the fiber cutter down to cut the fiber cables. Part@ For "1.0 mm "0.039 in or "1.3 mm "0.051 in fiber cables Notes: 1) The fiber cables should be cut in one stroke. 2) Once a fiber cable is cut off at a hole, do not use the hole again, if used, it degrades the cut surface quality and the detectability may deteriorate. 3) The blade cannot be replaced. Please purchase an additional fiber cutter, if required. 4) Note that the sensing range may be reduced by up to 20 % depending on the cut condition. Hence, decide the setting distance by taking sufficient margin. Others • Liquid in a pipe which is not transparent cannot be sensed correctly. • Unclear or highly viscous liquid may not be sensed. • Fit the fiber head to the pipe securely, otherwise the operation may be erroneous. • Take care that no dew condenses on the pipe’s sensing surface or the pipe’s inside wall and that no bubble attaches on the pipe’s inside wall, since it can affect the operation. • If a liquid drop flows down across the sensing point or an air bubble sticks on the wall at the sensing point, the operation may be erroneous. Make sure that no bubble arises in the liquid, and that no dew or liquid drop is present on either surface of the pipe wall. • Neither FD-F4 or FD-F9 is waterproof or chemicalresistant. Installation should be avoided at any place where it could come in direct contact with water or chemicals. • Do not apply excessive tensile force to the fiber cable. • Bending radius of the fiber cable must be R10 mm R0.394 in or more. If the bending radius is smaller than the specified value, the sensing performance may deteriorate. • Do not use the fiber at places having intense vibrations, as this can cause malfunction. • Keep the fiber head surface intact. If it is scratched or spoiled, the detectability will deteriorate. • Do not expose the fiber cable to any organic solvents. • Ensure that any strong extraneous light is not incident on the receiving face of the fiber head. • Take care that the sensor is not directly exposed to fluorescent light from a rapid-starter lamp or a high frequency lighting device as it may affect the sensing performance. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 617 SENSORS FOR SEMICONDUCTOR INDUSTRY Fiber cutter • The fiber cables should be cut off at the ends with the fiber cutter before insertion into the amplifier. Liquid Leak / Liquid Level Sensing FD-F4/F9 FD-F8Y EX-F1 Refer to p.1135l for general precautions and p.90/p.121/p.141/p.168l for amplifier precautions. Chemical-resistant FT-Z8Y PRECAUTIONS FOR PROPER USE Other Products FD-F4/F9 PRECAUTIONS FOR PROPER USE Refer to p.1135l for general precautions and p.90/p.121/p.141/p.168l for amplifier precautions. Teaching When using in combination with the FX-301(P), the FX-302(P) and the FX-303(P) • The threshold values can be set by either 2-level teaching or limit teaching, when the MODE indicator / TEACH (yellow) lights up. • This is the method of setting the threshold value by teaching two levels, corresponding to the liquid present and liquid absent conditions. Normally, setting is done by this method. Step Description • This is the method of setting the threshold value by teaching only the liquid absent condition (stable incident light condition). Step Display Press MODE key to light up MODE indicator / TEACH 1 (yellow). Press jog switch in the liquid absent condition. If the teaching is accepted, the read incident light intensity blinks in the display. Display Press MODE key to light up MODE indicator / TEACH 1 (yellow). Description Liquid absent 2 Fiber Pipe Press jog switch in the liquid absent condition. If the teaching is accepted, the read incident light intensity blinks in the digital display. 3 If jog switch is turned to the ‘  ’ side, ‘ ’ scrolls (twice) the display from left to right, and the threshold level is shifted to a  value approx. 15 % lower (higher sensitivity) than that set at 2. (Note 1) Liquid absent 2 MODE indicator / TEACH (yellow) blinks. Turn jog switch to the ‘  ’ side. Fiber High Pipe OFF 4 Threshold value SENSORS FOR SEMICONDUCTOR INDUSTRY FD-F4/F9 FD-F8Y EX-F1 Liquid Leak / Liquid Level Sensing FT-Z8Y Chemical-resistant Other Products FD-F4/F9 MODE indicator / TEACH (yellow) blinks. Press jog switch in the liquid present condition. 100 % Incident light intensity with liquid absent 15 % Threshold value ON Low Liquid present Turn to ‘’ side 3 5 If the teaching is accepted, the read incident light intensity blinks in the digital display and the threshold value is set at the mid-value between the incident light intensities in the liquid present and the 4 liquid absent conditions. After this, the judgment on the stability of sensing is displayed. • In case stable sensing is possible: ‘ ’ is displayed. Stability indicator (green) blinks. • In case stable sensing is not possible: ‘ ’ is displayed. Stability indicator (green) is off. 5 The threshold value is displayed. 6 ‘ 7 0 ’ blinks in the digital display. The incident light intensity appears in the digital display and the setting is complete. After this, the judgment on whether the setting shift amount can be shifted or not is displayed. • In case shifting is possible: ‘ ’ is displayed. ’ is displayed. • In case shifting is not possible: ‘ 6 The threshold value is displayed. 7 ‘ 8 ’ blinks in the digital display. The incident light intensity appears in the digital display and the setting is complete. Notes: 1) The approx. 15 % amount of shift is the initial value. The amount of shift can be changed in the PRO mode from approx. 5 to 80 % (5 % step). Refer to ‘Fiber Sensor Guide Book’ or ‘SUNX fiber sensor homepage’ (http://www.fiber-sensor.com) for details of the setting method. Notes: 2) Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. Note: Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. 618 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com Step When combining with the FX-311(P) • Adjust the sensitivity, : Lights up : Lights off observing the operation Sensing condition MODE Operation indicator indicator (orange). Light L-ON (ON when liquid absent) However, since the con- ( liquid ) absent D-ON (ON when liquid present) dition for lighting up of L-ON (ON when liquid absent) the indicator depends on Dark liquid the combination of the ( present ) D-ON (ON when liquid present) sensing condition and selected operation for L/D-ON, verify it from the table on the right. • The sensitivity adjuster is a 12-turn Pointer potentiometer. The maximum sensitivity is obtained by turning it fully clockwise. • The pointer shows the present sensitivity level. 4 6 8 Sensing method Make sure that the operation selection switch is set to LON (Light-ON). In case ‘assist Turn the sensitivity adjuster function’ is to be fully counterclockwise. 1 used, switch the (Minimum sensitivity) operation selection switch in the order of L-ON (Light-ON) n D-ON (Dark-ON) n L-ON (Light-ON). Liquid absent Fiber 2 Pipe • This product incorporates an ‘assist function’, which helps to easily search the optimum sensitivity position by blinking of the pointer. • In order to make ‘assist function’ effective, switch the operation selection switch in the order L-ON (Light-ON) n D-ON (Dark-ON) n L-ON (Light-ON). 0 Sensitivity indicator Operation MAX Liquid present 3 Notes: 1) ‘Assist function’ turns off automatically once the sensitivity adjustment has been completed. Notes: 2) In case ‘assist function’ is not to be used, set the operation selection switch to D-ON (Dark-ON) and wait for 2 sec., or more, to make ‘assist function’ ineffective. In the liquid absent condition, slowly turn the adjuster clockwise and find the point @ where the sensor is switched ON. The pointer blinks once at the point @. (Note 1) In the liquid present condition, slowly turn the adjuster further clockwise until the sensor goes into the ON state again. Once it is switched on, turn the adjuster counterclockwise a little and find the point b where it is switched OFF. The pointer blinks twice at the point b. (Note 2) If the sensor does not go into the ON state, MAX is the point b. ( 4 0 MAX ON A 0 MAX OFF B 0 MAX ON ) Turn the adjuster towards the point @ from the point b slowly. The pointer starts blinking when it approaches the optimum sensitivity point and blinks faster at the optimum sensitivity point for 3 sec. This point is the optimum sensitivity point. (Note 2) Optimum point B A 0 MAX 5 Select either L-ON (Light-ON) or D-ON (Dark-ON) according to your application. Notes: 1) When ‘assist function’ is not used, the pointer does not blink. Notes: 2) When ‘assist function’ is not used, the middle point of @ and b is regarded as the optimum sensitivity point. Notes: 3) In order to protect the mechanism, the sensitivity adjuster idles when over turned, which may result in a backlash of 1 to 2 divisions. Notes: 4) Depending upon the sensing conditions, stable sensing may be possible at a position which is slightly shifted from the optimum sensitivity point. Notes: 5) Do not move or bend the fiber cable after the sensitivity adjustment. Detection may become unstable. The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/ Refer to p.102/p.127/p.143/p.170 for amplifier dimensions. DIMENSIONS (Unit: mm in) FD-F41 FD-F91 FD-F4 FD-F9 8 0.315 13.5 25 0.531 0.984 Free-cut With FX-AT4 20 0.787 5 0.197 2-"3.2 "0.126 mounting holes 6 0.236 ("3)("0.118) Model No. tube (PVC) "1 "0.039 2 14 0.551 14 0.551 (20) (0.787) 2,000 78.740 (FD-F9: 5,000 196.850) 10 4 0.157 13 0.512 0.394 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 619 SENSORS FOR SEMICONDUCTOR INDUSTRY Sensitivity adjustment Liquid Leak / Liquid Level Sensing FD-F4/F9 FD-F8Y EX-F1 Refer to p.1135l for general precautions and p.90/p.121/p.141/p.168l for amplifier precautions. Chemical-resistant FT-Z8Y PRECAUTIONS FOR PROPER USE Other Products FD-F4/F9
FD-F41 价格&库存

很抱歉,暂时无法提供与“FD-F41”相匹配的价格&库存,您可以联系我们找货

免费人工找货
FD-F41
  •  国内价格 香港价格
  • 1+1441.799401+186.49680

库存:0