Fiber Sensor Guide Book
2014.06
panasonic.net/id/pidsx/global
GENERAL TERMS AND CONDITIONS
Please read this document carefully with respect to our product warranty policy before using our Panasonic Industrial Devices
SUNX products (“Products”). If you have any questions or comments regarding do’s and don’ts of the Products, please consult
your local Panasonic Industrial Devices SUNX authorized dealer for the correct use and application of the Products.
1. PRODUCT MODIFICATION & DISCONTINUANCE:
Panasonic Industrial Devices SUNX expressly reserves the right to modify, including the right to discontinue, any of the
Products, prior to their order, from time to time without notice.
2. WARRANTIES:
(1) Subject to the exclusions stated in 3 (EXCLUSIONS) herein below, Panasonic Industrial Devices SUNX warrants the
Products to be free of defects in material and workmanship for a period of one (1) year from the date of shipment under
normal usage in environments commonly found in manufacturing industry.
(2) Any Products found to be defective must be shipped to Panasonic Industrial Devices SUNX with all shipping costs paid
by Purchaser or offered to Panasonic Industrial Devices SUNX for inspection and examination. Upon examination by
Panasonic Industrial Devices SUNX, Panasonic Industrial Devices SUNX will, at its sole discretion, repair or replace at
no charge, or refund the purchase price of, any Products found to be defective.
3. EXCLUSIONS
(1) This warranty does not apply to defects resulting from any cause:
(i) which was due to abuse, misuse, mishandling, improper installation, improper interfacing, or improper repair by Purchaser;
(ii) which was due to unauthorized modification by Purchaser, in part or in whole, whether in structure, performance or specification;
(iii) which was not discoverable by a person with the state-of-the-art scientific and technical knowledge at the time of manufacture;
(iv) which was due to an operation or use by Purchaser outside of the limits of operation or environment specified by
Panasonic Industrial Devices SUNX;
(v) which was due to Force Majeure; and
(vi) which was due to any use or application expressly discouraged by Panasonic Industrial Devices SUNX in 5 (CAUTIONS
FOR SAFE USE) hereunder.
(2) This warranty extends only to the first purchaser for application, and is not transferable to any person or entity which
purchased from such purchaser for application.
(3) The performance data presented in this catalogue is only for guidance and shall not constitute any performance warranty
by Panasonic Industrial Devices SUNX.
4. DISCLAIMERS
(1) Panasonic Industrial Devices SUNX’s sole obligation and liability under this warranty is limited to the repair or
replacement, or refund of the purchase price, of a defective Product, at Panasonic Industrial Devices SUNX’s option.
(2) THE REPAIR, REPLACEMENT, OR REFUND IS THE EXCLUSIVE REMEDY OF THE PURCHASER, AND ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE HEREBY EXPRESSLY DISCLAIMED. IN NO EVENT SHALL PANASONIC INDUSTRIAL DEVICES
SUNX AND ITS AFFILIATED ENTITIES BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE
PRODUCTS, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR
ANY DAMANGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS
OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN
CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS.
5. CAUTIONS FOR SAFE USE
(1) The applications shown in this catalogue are only suggestions, and it is Purchaser’s sole responsibility to ascertain the
fitness and suitability of the Products for any particular application, as well as to abide by Purchaser’s applicable local
laws and regulations, if any.
(2) Never use the Products NOT rated or designated as “SAFETY SENSOR” in any application involving risk to life or
property. When such a use is made by Purchaser, such Purchaser shall indemnify and hold harmless
Panasonic Industrial Devices SUNX from any liability or damage whatsoever arising out of or in relation to such use.
(3) In incorporating the Products to any equipment, facilities or systems, it is highly recommended to employ fail-safe
designs, including but not limited to a redundant design, flame propagation prevention design, and malfunction
prevention design so as not to cause any risk of bodily injury, fire accident, or social damage due to any failure of such
equipment, facilities or systems.
(4) The Products are each intended for use only in environments commonly found in manufacturing industry, and, unless
expressly allowed in this catalogue, specification or otherwise, shall not be used in, or incorporated into, any equipment,
facilities or systems, such as those:
(a) which are used for the protection of human life or body parts;
(b) which are used outdoors or in environments subject to any likelihood of chemical contamination or electromagnetic
influence;
(c) which are likely to be used beyond the limits of operations or environments specified by
Panasonic Industrial Devices SUNX in this catalogue or otherwise;
(d) which may cause risk to life or property, such as nuclear energy control equipment, transportation equipment
(whether on rail or land, or in air or at sea), and medical equipment;
(e) which are operated continuously each day for 24 hours; and
(f) which otherwise require a high level of safety performance similar to that required in those equipment, facilities or
systems as listed in (a) through (e) above.
6. EXPORT CONTROL LAWS
In some jurisdictions, the Products may be subject to local export laws and regulations. If any diversion or re-export is to be
made, Purchaser is advised to abide by such local export laws and regulations, if any, at its own responsibility.
7. PURCHASER’S TRASFER OBLIGATIONS
If Purchaser resell or deliver the Products to a third party, Purchaser must provide such third party with a copy of this
document, all specifications, manuals, catalogs, leaflets and written information of any kind provided to Purchaser by
Panasonic Industrial Devices SUNX or its authorized local representative from time to time regarding the Products.
INDEX
Fiber Selection Guide Choose by model
Choose by shape/application
3
How to read Model No.
4
Earlier model comparison table
6
New Product Introduction Tough Fiber
Fibers
2
8
Super Quality
10
Threaded Type
12
Square Head Type
14
Cylindrical Type
16
Sleeve
18
Flat Type
20
Small Spot
22
Narrow Beam
24
Wide Beam
25
Convergent Reflective Type
26
Retroreflective Type
27
Chemical / Oil-resistant
28
Heat-resistant
30
Vacuum-resistant
32
Liquid Leak / Liquid Detection
34
Fiber Options
42
Semi-custom Fibers
46
Fiber Dimensions
Amplifiers
INDEX
Thru-beam Type
48
Retroreflective Type
55
Reflective Type
56
Others
66
FX-500 series Ver.2
70
FX-100 series
98
112
2
New product
introduction
Tough
Fiber
Fiber Selection Guide
Choose by model
Thru-beam type
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Retroreflective type
Page
Model No.
FT-140
FT-30
FT-31
FT-31S
FT-31W
FT-40
FT-42
FT-42S
FT-42W
FT-43
FT-45X
FT-A11
FT-A11W
FT-A32
FT-A32W
FT-AL05
FT-E13
FT-E23
FT-F93
FT-H13-FM2
FT-H20-J20-S
FT-H20-J30-S
FT-H20-J50-S
FT-H20-M1
FT-H20-VJ50-S
FT-H20-VJ80-S
FT-H20W-M1
FT-H30-M1V-S
FT-H35-M2
FT-H35-M2S6
FT-HL80Y
FT-KS40
FT-KV26
FT-KV40
FT-KV40W
FT-L80Y
FT-R31
FT-R40
FT-R41W
FT-R42W
FT-R43
FT-R44Y
FT-R60Y
FT-S11
FT-S20
FT-S21
FT-S21W
FT-S30
FT-S31W
FT-S32
FT-V23
FT-V24W
FT-V25
FT-V30
FT-V40
FT-V80Y
FT-Z20HBW
FT-Z20W
Page
Sensing range
Dimensions
Specifications
P.12
P.11
P.12
P.19
P.12
P.11
P.12
P.19
P.48
P.12
Model No.
FT-Z30
FT-Z30E
FT-Z30EW
FT-Z30H
FT-Z30HW
FT-Z30W
FT-Z40HBW
FT-Z40W
FT-Z802Y
Sensing range
Dimensions
Specifications
P.53
P.20
P.35
P.30
P.50
P.32
P.30
P.29
P.24
P.51
P.15
P.15/P.29
P.16
P.11
P.52
P.11
P.16
P.19
P.20
P.24/P.27
P.55
P.29
Page
Model No.
P.16/P.19
P.16
P.29
FR-KZ22E
FR-KZ50E
FR-KZ50H
FR-Z50HW
Sensing range
Dimensions
Specifications
P.54
P.49
P.16
Model No.
Reflective type
P.25
P.29
P.15
P.12
Page
P.53
FD-30
FD-31
FD-31W
FD-32G
FD-32GX
FD-40
FD-41
FD-41S
FD-41SW
FD-41W
FD-42G
FD-42GW
FD-60
FD-61
FD-61G
FD-61S
FD-61W
FD-62
FD-64X
FD-A16
FD-AL11
FD-E13
FD-E23
FD-EG30
FD-EG30S
FD-EG31
FD-F4
FD-F41
FD-F41Y
FD-F71
FD-F8Y
FD-FA93
FD-H13-FM2
FD-H18-L31
FD-H20-21
FD-H20-M1
FD-H25-L43
FD-H25-L45
Page
Sensing range
Dimensions
Specifications
P.11
P.13
P.13/P.23
P.11
P.13
P.56
P.19
P.13
P.13/P.23
P.11
P.13
P.57
P.19
P.13
P.25
P.58
P.17/P.19
P.13/P.23
P.19
P.13/P.23
P.59
P.35
P.31
P.60
Model No.
FD-H30-KZ1V-S
FD-H30-L32
FD-H30-L32V-S
FD-H35-20S
FD-H35-M2
FD-H35-M2S6
FD-HF40Y
FD-L10
FD-L11
FD-L12W
FD-L20H
FD-L21
FD-L21W
FD-L22A
FD-L23
FD-L30A
FD-L31A
FD-L32H
FD-R31G
FD-R32EG
FD-R33EG
FD-R34EG
FD-R41
FD-R60
FD-R61Y
FD-S21
FD-S30
FD-S31
FD-S32
FD-S32W
FD-S33GW
FD-S60Y
FD-V30
FD-V30W
FD-V50
FD-Z20HBW
FD-Z20W
FD-Z40HBW
FD-Z40W
FD-Z50HW
Sensing range
Dimensions
Specifications
P.32
P.31
P.32
P.61
P.31
P.35
P.26
P.62
P.15/P.23
P.63
P.15
P.13
P.15/P.29
P.17
P.11
P.17
P.64
P.29
P.19
P.21
P.24
P.65
3
Fiber Selection Guide
New product
introduction
Choose by shape
Tough
Fiber
Threaded Type
Square Head Type
Cylindrical Type
Sleeve
Flat Type
S
tandard type which
is mounted using
nuts.
Installed cleanly on
the side of a
conveyor belt.
H
as a slender shape
that is mounted
using set screws.
S
uitable for sensing
in narrow locations
and sensing minute
objects.
hin and rectangular
T
shape. Installed directly
in narrow locations
with screws.
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
P.12
P.14
P.16
P.18
P.20
Fibers
Super
Quality
Threaded
Type
Choose by beam shape
Square Head
Type
Small Spot
Narrow Beam
Wide Beam
Convergent
Reflective Type
Retroreflective Type
S
enses minute
objects using a spot
lens.
N
ot easily affected
by surrounding
obstacles.
S
enses in the beam
band without missing
a work.
S
enses in the limited
range only.
I deal for sensing
transparent objects
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
P.22
Choose by quality
P.24
P.25
P.26
P.27
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Choose by environment / performance
Super Quality
Chemical / Oil-resistant
Heat-resistant
Vacuum-resistant
Liquid Leak /
Liquid Detection
The variance of
beam intensity and
beam axis is
extremely small.
V
arious kinds of liquids
can be detected due to
the fluorine contained
resin case
W
ithstands at -60 °C
-76 °F to 350 °C 662 °F
U
sable in hightemperatures of
300 °C 572 °F and
vacuum
C
orresponds to
various liquid
events.
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
P.10
P.28
P.30
P.32
P.34
Fiber sensor amplifiers guidance
Digital fiber sensor
FX-500 series Ver. 2
Amplifiers
S
uper functionality,
yet, economical price
P.70
Reflective
Type
Others
Digital fiber sensor
FX-100 series
A
t the industry's
leading edge
Retroreflective
Type
FX-500
series
FX-100
series
P.98
INDEX
4
New product
introduction
Tough
Fiber
Fiber Selection Guide
How to read Model No.
Applies to the fiber in (P.10~P.35)
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
F
Series Name
-
*1
Type
*1
Shape, etc.
Functions / Features
*1: Excluding liquid leak / liquid detection fiber
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Symbol
Details
T
Thru-beam type
D
Reflective type
R
Retroreflective type
Symbol
None
G
S
H
E
HB
A
Square Head
Type
Cylindrical
Type
Details
General-purpose
Coaxial reflective
Sleeve
Top sensing *
Side sensing *
Top sensing + Bent *
Alignment
* is for Flat type (Z and KZ)
only
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Symbol
None
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
R
S
KS
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
V
KV
E
EG
Z
Reflective
Type
Others
KZ
A
Amplifiers
FX-500
series
FX-100
series
AL
L
F
INDEX
Lead
No.
3
4
Treaded type
6
14
4
Elbow or square head
6
1
2
Cylindrical type
3
Narrow beam
4
2
3
Side-view
4
5
4
Narrow beam / Side-view
2
1
Ultra small diameter
2
Coaxial
3
2
3
Flat type
4
5
2
Narrow beam
5
3
Wide beam
1
1
Array
0
1
2
Convergent reflective type
3
9
Liquid leak / Liquid detection
7
Details
Details
M3
M4
M6
M14
M4
M6
ø1 mm
ø1.5 mm
ø2.5 or ø3 mm
ø3.7 mm
ø2 mm
ø2.5 or ø3 mm
ø4 mm
ø5 mm
ø4 mm
1.5 × 2 mm
Fiber ø0.125 mm
Fiber ø0.25 mm
M3
Thickness 2 mm
Thickness 3 mm
Thickness 3.5 mm
Thickness 5.2 mm
Thickness 2.2 mm
Thickness 5.2 mm
Sensing width 32 mm
Sensing width 10 to 19 mm
Sensing width 11.1 mm
Sensing width 5.5 mm
Sensing range 0 to 10 mm (STD)
Sensing range 11 to 30 mm (STD)
Sensing range 31mm or more (STD)
Mountable on pipe
Liquid leak
Symbol
None
W
X
Y
Details
General-purpose
Sharp bending
Stainless-jacketed
Chemical-resistant
5
6
New product
introduction
Tough
Fiber
Fiber Selection Guide
specification of new fiber may be changed from that
Earlier Models Comparison Table(The
of old one. Please confirm the specification before use. )
Thru-beam type
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Old fiber
New fiber
Model No.
Model No.
FT-A30
FT-A32
FT-A8
FT-A11
FT-AFM2
FT-AFM2E
FT-B8
FT-43
FT-E12
FT-E13
Super
Quality
FT-E22
FT-E23
FT-F902
FT-F93
FT-FM10L
FT-140
FT-FM2
FT-42
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
FT-FM2S
FT-FM2S4
FX-500
series
FX-100
series
INDEX
FT-42S
P.25
P.12
P.16/P.19
P.19
FT-KV8
FT-KV40
FT-NFM2
FT-31
P.12
FT-31S
P.19
FT-S21
FT-P40
FT-31
FT-P60
FT-P80
FT-42
P.49
P.48
FT-KV26
FT-P2
P.48
P.12
FT-KV1
FT-NFM2S4
P.49
P.35
FT-KS40
FT-NFM2S
Old fiber
New fiber
Model No.
Model No.
FT-WKV8
FT-K8
P.24
P.16
P.12
P.51
P.48
P.52
P.48
FT-KV40
FT-KV40W
FT-WR80
FT-R41W
FT-WR80L
FT-R42W
FT-WS3
FT-S31W
FT-WS4
FT-S21W
FT-WS8
FT-S31W
FT-WS8L
FT-S32
FT-WV42
FT-V25
FT-V24W
FT-WZ4
FT-Z20W
FT-WZ4HB
FT-Z20HBW
FT-WZ7
FT-Z40W
FT-WZ7HB
FT-Z40HBW
FT-WZ8
FT-WZ8E
FT-WZ8H
FT-Z30H
FT-R80
FT-R40
P.12
P.51
FT-S32
P.16
P.52
FT-SFM2SV2
FT-V30
P.19
FT-SNFM2
FT-S21
FT-T80
―
FT-30
―
FT-40
―
FT-S20
P.53
―
FT-S30
P.16
P.52
―
FT-R31
FT-42
P.12
P.48
―
FT-R43
FT-V10
FT-V40
P.16
P.53
FT-V22
FT-V23
FT-V41
FT-V25
FT-SFM2
FT-SFM2L
FT-W4
FT-W8
FT-WA8
P.19
FT-42
FT-A11W
P.53
P.54
P.53
P.54
P.20
P.53
P.54
P.53
P.54
P.48
P.11
P.52
P.15
P.51
Retroreflective type
P.12
P.48
FT-A32
FT-A11
P.19
P.52
FT-42W
FT-A32W
P.52
P.53
FT-31
FT-31W
P.16
FT-Z30HW
FT-Z8H
P.52
P.15
FT-Z30EW
FT-Z30E
P.16
P.51
FT-Z30H
FT-Z8E
FT-S11
P.24
FT-Z30W
FT-Z30E
P.49
FT-PS1
Sensing range
Dimensions
Specifications
FT-Z30
FT-Z30
FT-45X
Page
FT-S21
FT-Z8
FT-P81X
FT-WA30
Amplifiers
Sensing range
Dimensions
Specifications
FT-AL05
Fibers
Threaded
Type
Page
P.25
P.49
Old fiber
New fiber
Model No.
Model No.
FR-KV1
FR-KZ22E
FR-KZ21
FR-KZ50H
FR-KZ21E
FR-KZ50E
FR-WKZ11
FR-Z50HW
Page
Sensing range
Dimensions
Specifications
P.24/P.27
P.55
7
Fiber Selection Guide
New product
introduction
Reflective type
Old fiber
Model No.
FD-A15
FD-AFM2
FD-AFM2E
New fiber
Model No.
FD-AL11
FD-62
FD-E12
FD-E13
FD-E22
FD-E23
FD-EG1
FD-EG30
FD-EG3
FD-EN500S1
FD-ENM1S1
FD-EG31
FD-F71
FD-FA90
FD-FA93
FD-FM2S
FD-FM2S4
P.25
P.13
P.17/P.19
FD-61
FD-61G
FD-61S
FD-G4
FD-42G
FD-G6
FD-32G
FD-G6X
FD-32GX
FD-L4
FD-L20H
FD-L41
FD-L21
FD-L43
FD-L22A
FD-L44
FD-L11
FD-L44S
FD-L10
FD-L45
FD-L30A
FD-L45A
FD-L31A
FD-L46
FD-L32H
P.19
P.58
P.19
Model
FD-SNFM2
FD-S31
P.17
P.64
FD-T40
FD-31
Choose
by shape/
application
FD-T80
FD-V41
FD-WL41
FD-WL48
FD-WS8
P.13/P.23
P.56
FD-WSG4
FD-WT4
FD-WT8
P.62
P.26
FD-WV42
FD-WZ4
FD-L23
FD-41
P.13
FD-41S
P.19
FD-P2
FD-S21
P.17
FD-P40
FD-31
P.13
FD-P50
FD-S32
P.17
FD-P60
FD-41
FD-P80
FD-61
FD-P81X
FD-64X
FD-R80
FD-R60
FD-S80
FD-S32
P.13
P.56
P.13
P.57
FD-41
P.56
FD-V30
P.64
FD-41S
P.19
FD-41SW
FD-61
FD-61W
FD-42G
FD-42GW
FD-Z50HW
P.56
FD-L21W
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
P.13
P.57
P.13/P.23
P.24
P.65
P.26
P.62
FD-L21
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
FD-L12W
Small
Spot
FD-S32
Narrow
Beam
FD-S32W
P.17
P.64
FD-S33GW
FD-31W
FD-41
P.13
P.56
FD-V30W
P.19
P.64
FD-Z20HBW
FD-Z40W
P.62
FD-WZ7HB
FD-Z40HBW
―
FD-30
―
FD-40
―
FD-60
P.63
―
FD-S30
P.56
―
FD-R31G
P.64
―
FD-R32EG
P.56
―
FD-R33EG
P.57
―
FD-R34EG
P.58
―
FD-R41
Chemical / Oilresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
FD-Z20W
FD-WZ7
Retroreflective
Type
Heatresistant
FD-41W
FD-V30
Wide
Beam
Convergent
Reflective
Type
FD-31
FD-WZ4HB
P.63
P.17
FD-61
P.63
P.56
Fiber
Selection
Guide
P.65
FD-WKZ1
P.57
Sensing range
Dimensions
Specifications
P.19
P.59
P.13
Page
FD-V50
FD-W44
P.35
New fiber
Model No.
FD-SFM2SV2
FD-WG4
FD-NFM2
FD-NFM2S4
P.57
P.13/P.23
FD-L47
FD-NFM2S
P.58
Old fiber
Model No.
FD-W8
FD-EG30S
FD-F705
FD-FM2
Sensing range
Dimensions
Specifications
FD-A16
FD-B8
FD-EG2
Page
Tough
Fiber
P.21
P.65
P.56
P.11
P.57
P.64
P.15/P.23
P.15
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
P.63
Retroreflective
Type
Reflective
Type
Others
P.64
Amplifiers
FX-500
series
FX-100
series
INDEX
8
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Tough Fiber
Unbreakable ! More flexible ! ECO !
Conventional 3 types rolled into 1 !!
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Flexible fiber
Flexible durability
Fibers
Super
Quality
Threaded
Type
1
million
times
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Sharp bending fiber
Bending radius
R2
~R1
mm
Chemical / Oilresistant
General purpose fiber
Heatresistant
Bending radius
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Unbreakable
Flexible durability
10 million times
(Typical)
Bending conditions Bending radius: R10 mm
Reciprocating bending: 180°
More flexible
~R4
Bending radius R2 mm
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Tough Fiber
R25mm
ed
gs are us
steel fittin
ls.
e
d
o
m
ll
Stainless
head of a
r
e
b
fi
e
for th
s to RoHS
tery
nform
Clearly co d for secondary bat
se
u
th
e
g
b
n
re
an
st
C
mounting
Improved
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
New tough fibers exceed normal optic fibers!
Tough fibers can be used on moving parts, can be bent with precision, and offer high quality for all purposes.
They go beyond what was commonly thought to be possible.
9
Unbreakable
ECO
Bending conditions
Bending radius: R10 mm R0.394 in,
Reciprocating bending: 180°
Stainless steel fittings
are used for the fiber head
of all models.
Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
● Improved
tightening torque
(Typical)
Example: FT-31
Fiber
Selection
Guide
● Can be used for
secondary batteries
10 million times
More flexible
Tough
Fiber
● Clearly conforms
to RoHS
SUS
Flexible durability
New product
introduction
Fibers
Super
Quality
R2 to R4 mm R0.079 to R0.157 in
Threaded
Type
Example: FT-42
Square Head
Type
Cylindrical
Type
R
R2
mm
R0.079 in
M3
M4
R4
mm
R0.157 in
Sleeve
R
Flat
Type
Small
Spot
Narrow
Beam
Ø2.2 mm
Ø0.087 in
Ø1 mm
Ø0.039 in
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Reduced the time in selecting fiber and in registrating part numbers
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
For Designers
High-q
uality
● High-quality
in whichever
tough fiber you choose!
● Easy
selection!
● Reduces
risk of breaking and
bending during installation!
For Buyers
Low P
rice
Fiber
Options
● Cost
savings!
● Reduced registration of part
numbers!
● Reduced maintenance time
in keeping stocks and
replacement!
Reduced variation in detection
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Beams at the fiber aperture are uniform, leading to stable sensing.
Previous
flexible fiber
Previous sharp Generally flexible fibers and
bending fiber sharp bending fibers are
composed of multiple fiber
cores, often resulting in large
variations in light intensity.
New fiber
The new standard fiber is
composed of a single fiber
core, achieving uniform light
intensity.
●Uniform and highly accurate sensing
●Stable sensing even if the fiber is bent
Amplifiers
FX-500
series
FX-100
series
INDEX
10
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
Super Quality
It is a fiber with superior light intensity stability and
simple digital management when combined with the
FX-500 series amplifier.
It offers stable sensing with an extremely small beam
axis curvature and gap.
FT-40
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Digital management is simple due to small differences in body.
When connected with the FX-500 series amplifiers, it has up to
4 times improved stability of incident light intensity compared
with traditional fibers. Management is simple even when
replacing amplifiers because the digital display shows the
approximate value.
Super quality fiber
FX-500 series
“Stabilized incident light intensities”
even in multiple units
Emitter intensity is also stable due to few curvatures and gaps
in the beam axis.
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Stable emission amount within ±10 %
ø2.2 mm ø0.087 in standard fiber
Variation in emission amount of the fiber core is
controlled down to less than ±10 %, achieving a
stable detection.
● Beam axis deviation: Thru-beam type within ±2°,
Reflective type within ±3°
● Beam axis centering precision: within ±150 µm
Single core standard fiber
with high flexibility
Previous
Retroreflective
Type
New material
Convergent
Reflective
Type
Expanded temperature range
Fiber
Options
Semi-custom
fibers
Ambient temperature [–40 to +70 °C –40 to +158 °F in previous model]
–55 to +80 °C 1.2
–67 to +176 °F
times
more than
previous model
More flexible! R4
In general, high-flexibility
types adopt a multi-fiber core,
which may result in large
variation in light emission.
Bending radius [Previous model is R25 mm R0.984 in]
R4 mm
R0.157 in
1/6
of that of
previous model
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Integrated high-precision plug
The centering precision of
the fiber core attached to the
inserting plug is doubled.
As the insertion precision is
increased, the variation among
units can be greatly suppressed.
● Centering precision: within ±40 µm
More bendable!
Bending durability [Previous model is 1,000 times]
10 million times
10,000 times
more than previous model
* Bending conditions
Bending radius: R10 mm R0.394 in,
Reciprocating bending 180°
11
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
LIST OF FIBERS
Earlier models
comparison
table
Thru-beam type (one pair set)
M3
M3
Model No.
7RXJK
FT-30
12
M4
M4
Threaded
Type
Shape of fiber head
(mm)
7RXJK
FT-40
ø1·5
ø1.5
10
ø3
ø3
Cylindrical
15
10
7RXJK
FT-S20
7RXJK
FT-S30
Bending Fiber
radius cable
(mm) length
R2
Bending
durability
R4
Bending
durability
R2
2m
Bending
durability
R4
Bending
durability
Sensing range (mm in)
FX-500 series
STD
400 15.748
HYPR
1,350 53.150
STD
1,200 47.244
HYPR
(Note) 3,600 141.732
STD
400 15.748
HYPR
1,350 53.150
STD
1,200 47.244
HYPR
(Note) 3,600 141.732
U-LG
LONG
FAST
H-SP
810 31.890
650 25.591
210 8.268
75 2.953
2,200 86.614
1,700 66.929
530 20.866
190 7.480
810 31.890
650 25.591
210 8.268
75 2.953
2,200 86.614
1,700 66.929
530 20.866
190 7.480
Beam axis
FX-101 Beam position/ Optical
Ambient
(Upper value) axis dia. Inclination transmission Protection temp. Dimensions
(mm)
of
beam
l
o
ss
FX-102
(Lower value)
axis
135 5.315 ø0.5
400 15.748
P.48
320 12.598
870 34.252
ø1
135 5.315 ø0.5
400 15.748
150 μm
±10 %
/±2°
IP67
–55 to
+80 °C
M3
Model No.
FD-30
M4
7RXJK
FD-40
Bending
durability
14
M6
Threaded
M4
R2
FD-60
17
ø3
2m
7RXJK
M6
ø3
10
7RXJK
FD-S30
R4
Bending
durability
Cylindrical
Type
Small
Spot
Wide
Beam
Convergent
Reflective
Type
Beam axis
position/
Optical
Ambient
Inclination transmission Protection
Dimensions
temp.
of beam
loss
(Lower value) axis
Sensing range (mm in) (Note)
FX-101
U-LG
(Upper value)
LONG
FX-500 series
FX-102
FAST
H-SP
7RXJK
M3
12
Cylindrical
Bending Fiber
radius cable
(mm) length
Square Head
Type
Narrow
Beam
ø1
Reflective type
Shape of fiber head
(mm)
Threaded
Type
Flat
Type
Note: The fiber cable length practically limits the sensing range.
Type
Super
Quality
Sleeve
P.52
320 12.598
870 34.252
Fibers
STD
160 6.299
HYPR
600 23.622
330 12.992
250 9.843
80 3.150
25 0.984
STD
900 35.433
740 29.134
140 5.512
260 10.236 420 16.535
90 3.543
HYPR
520 20.472
1,550 61.024
STD
160 6.299
HYPR
600 23.622
330 12.992
250 9.843
80 3.150
25 0.984
45 1.772
155 6.102
P.56
150 μm
/±3°
±10 %
IP67
Note: The sensing range is specified for white non-glossy paper.
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
–55 to
+80 °C
45 1.772
155 6.102
Retroreflective
Type
P.57
P.64
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
12
New product
introduction
Tough
Fiber
Threaded Type
It is a standard fiber which is mounted using nuts. It
has reasonable pricing while drastically improving
flexing performance.
With the lens installable type, long distance sensing and
microscopic object sensing is possible by installing a lens.
A protective tube and a sturdy stainless jacket type that
prevents disconnection are also prepared.
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Stainless steel fittings are used for the fiber
head of all models.
● Clearly conforms to RoHS
● Can be used for secondary battery
● Improved mounting strength
Thru-beam type (one pair set)
Fiber
Options
Shape of fiber head
(mm)
M3
Model No.
7RXJK
FT-31
12
M3
Semi-custom
fibers
M3
FT-31W
12
Lens mountable
Fiber
Dimensions
M4
FT-43
15
Thru-beam
Type
M4
7RXJK
FT-42
R2
Bending
durability
R1
R4
Bending
durability
15
Lens mountable
M4
M4
Threaded
Lens mountable
Fiber
Bending cable
radius length
:
(mm)
Free-cut
FT-42W
R1
FT-45X
R4
15
Lens mountable, Stainless-jacketed
M4
20
M14
FX-100
series
Long range Elbow
Amplifiers
FX-500
series
INDEX
Improved specularity
High precision polishing is accomplished by
using the PCTC polishing technique.
The specularity of the end face of the fiber is
5 times greater.
● Light intensity is increased, enabling stable sensing.
LIST OF FIBERS
Type
Others
The beam axis deviation of each unit is kept
within ±3º and the beam axis centering accuracy
is kept within ±150 μm.
(Within ±5º and ±90 μm for ultra small diameter fibers)
● Makes beam axis adjustment easier
● Improves mounting hole machining accuracy
● Improves sensing accuracy
SUS
Supports spot
lenses and zoom
lenses!
Heatresistant
Reflective
Type
Improved centering accuracy
It is a coaxial fiber that encloses the circumference of
the emitter fiber at the center with the receiver fiber.
This is suitable for high-precision positioning. It can
perform sensing without affecting the approach
direction of the work.
Chemical / Oilresistant
Retroreflective
Type
More user-friendly, high quality fiber
Coaxial type FD-□G□ in which highprecision positioning can be achieved.
Retroreflective
Type
Liquid Leak /
Liquid Detection
F
T-31/31W/43/42/42W
FT-45X/R40
FD-31/41/62/61/R60
* Some models not included (FT-140)
Convergent
Reflective
Type
Vacuumresistant
FT-42
Lens mountable
7RXJK
15
M4
With expansion lens
FT-R40
M14 7RXJK
FT-140
40
R4
Bending
durability
Beam axis
FX-101 Beam position/
Ambient
(Upper value) axis dia. Inclination Protection temp. Dimensions
FX-102 (mm) of beam
(Lower value)
axis
Sensing range (mm in) (Note 1)
FX-500 series
STD
315 12.402
HYPR
1,350 53.150
STD
260 10.236
HYPR
990 38.976
STD
1,400 55.118
2 m HYPR
(Note 2) 3,600 141.732
STD
1,130 44.488
HYPR
(Note 2) 3,600 141.732
STD
800 31.496
HYPR
3,300 129.921
STD
1,200 47.244
1m
HYPR
(Note 2) 1,600 62.992
STD
930 36.614
2 m HYPR
(Note 2) 3,600 141.732
STD
(Note 2) 19,600 771.654
10 m HYPR
(Note 2) 19,600 771.654
U-LG
LONG
FAST
H-SP
770 30.315
150 μm
–55 to
550 21.654
130 5.118
210 8.268
340 13.386
/±2°
+80 °C
70 2.756
ø0.5
590 23.228
150 μm
–40 to
440 17.323
80 3.150
150 5.906
240 9.449
/±3°
+60 °C
53 2.087
2,800 110.236
2,100 82.677
350 13.780
P.48
770 30.315
970 38.189 ø1.5
240 9.449
150 μm
–55 to
/±2°
+80 °C
2,050 80.709
1,600 62.992
300 11.811
530 20.866
800 31.496
190 7.480
IP67
1,900 74.803
150 μm
–40 to
1,400 55.118
260 10.236
490 19.291
720 28.346
/±3°
+60 °C
160 6.299
ø1
1,600 62.992(Note 2)
1,600 62.992(Note 2)
340 13.386
P.49
630 24.803
920 36.220
200 7.874
150 μm
–55 to
/±2°
+80 °C
1,750 68.898
1,500 59.055
270 10.630
P.51
500 19.685
740 29.134
160 6.299
19,600 771.654(Note 2)
551.181
–40 to
19,600 771.654(Note 2) 14,000
19,600 771.654 ø10
―
P.48
16,000 629.921
+70 °C
(Note 2)
6,300 248.031
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
13
Application
FIBER OPTIONS
Lens
Lens
(For thru-beam type fiber) (For reflective type fiber)
Detecting a presence of a workpiece
FD-32G
P.42
New product
introduction
Tough
Fiber
▲
▲
P.43
Fiber
Selection
Guide
Model
▲
Protective tube P.45
Choose
by shape/
application
·FTP-□
·FDP-□
How to read
Model No.
Earlier models
comparison
table
LIST OF FIBERS
Reflective type
Type
Shape of fiber head
(mm)
12
M3
12
Coaxial, Lens mountable
M3
M3
17
Coaxial, Lens mountable,
Stainless-jacketed
M3
Ultra-small diameter
18
Coaxial, Lens mountable
M3
16
Coaxial, Lens mountable
M3
16
M4
14
M4
Threaded
M4
14
Coaxial, Lens mountable
M4
25
Coaxial, Lens mountable
M4
25
M6
17
M6
17
M6
17
Coaxial
M6
17
Stainless-jacketed
M6
Elbow
22
15
M6
Beam axis
position/
Ambient
Inclination Protection
Dimensions
temp.
of beam
(Lower value) axis
Sensing range (mm in) (Note 1, 2)
FX-101
U-LG
(Upper value)
LONG
FX-500 series
FX-102
FAST
H-SP
290 11.417
220 8.661
80 3.150
25 0.984
STD
125 4.921
35 1.378
FD-31
Bending
140 5.512
HYPR
durability
515 20.276
STD
180 7.087
80 3.150
140 5.512
15 0.591
FD-31W
R1 2 m HYPR
45 1.772
60 2.362
12 0.472
330 12.992
STD
380 14.961
7RXJK
R2
200 7.874
270 10.630
70 2.756
FD-32G
Bending
95 3.740
190 7.480
HYPR
27 1.063
durability
650 25.591
STD
410 16.142
200 7.874
360 14.173
75 2.953
FD-32GX
R2 1 m HYPR
100 3.937
210 8.268
(Note 3)
30 1.181
630 24.803
STD
130 5.118
48 1.890
110 4.331
20 0.787
FD-EG30
30 1.181
70 2.756
HYPR
9 0.354
170 6.693
500
mm
R4
STD
45 1.772
20 0.787
35 1.378
7 0.276
FD-EG31
12 0.472
25 0.984
HYPR
3.5 0.138
85 3.346
290 11.417
STD
7RXJK
R2
125 4.921
220 8.661
35 1.378
FD-41
Bending
80 3.150
140 5.512
HYPR
25 0.984
durability
515 20.276
STD
630 24.803
270 10.630
430 16.929
80 3.150
FD-41W
R1
150 5.906
230 9.055
HYPR
45 1.772
900 35.433
STD
380 14.961
7RXJK
R2
200 7.874
270 10.630
70 2.756
FD-42G
Bending
95 3.740
190 7.480
HYPR
27 1.063
durability
650 25.591
STD
340 13.386
150 5.906
280 11.024
45 1.772
FD-42GW R1
90 3.543
140 5.512
HYPR
25 0.984
670 26.378
2 m STD
1,000 39.370
520 20.472
940 37.008
170 6.693
FD-62
340 13.386 450 17.717
HYPR
R4
110 4.331
1,500 59.055
Bending
STD
840 33.071
7RXJK
durability
450 17.717
670 26.378
120 4.724
FD-61
200 7.874 410 16.142
HYPR
70 2.756
1,400 55.118
STD
630 24.803
270 10.630
430 16.929
80 3.150
FD-61W
R1
150 5.906
230 9.055
HYPR
45 1.772
900 35.433
STD
800 31.496
7RXJK
R4
420 16.535
650 25.591
120 4.724
FD-61G
Bending
200 7.874 350 13.780
HYPR
60 2.362
durability
1,100 43.307
500 19.685
STD
280 11.024
410 16.142
75 2.953
FD-64X
R4 1 m HYPR
160 6.299
220 8.661
50 1.969
670 26.378
STD
600 23.622
7RXJK
R4
290 11.417
550 21.654
110 4.331
FD-R60
Bending 2 m HYPR
190 7.480
240 9.449
65 2.559
durability
1,100 43.307
7RXJK
M3
M6
Model No.
Fiber
Bending cable
radius length
:
(mm)
Free-cut
R2
150 μm
/±3°
–55 to
+80 °C
Sleeve
P.56
―
Flat
Type
Small
Spot
–55 to
+80 °C
Narrow
Beam
―
Wide
Beam
IP40
―
–40 to
+70 °C
P.58
―
–20 to
+60 °C
P.59
IP67
–40 to
+60 °C
―
–55 to
+80 °C
Retroreflective
Type
Chemical / Oilresistant
Vacuumresistant
P.56
―
Convergent
Reflective
Type
Heatresistant
–55 to
+80 °C
Liquid Leak /
Liquid Detection
Fiber
Options
IP40
―
–40 to
+60 °C
150 μm
/±3°
–55 to
+80 °C
Semi-custom
fibers
P.57
IP67
Thru-beam
Type
Reflective
Type
–40 to
+60 °C
―
Fiber
Dimensions
Retroreflective
Type
Others
―
IP40
–55 to
+80 °C
―
150 μm
/±3°
IP67
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper.
3) The allowable cutting range is 700 mm 27.559 in from the end that the amplifier inserted.
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
Threaded
Type
Cylindrical
Type
–40 to
+60 °C
150 μm
/±3°
Super
Quality
Square Head
Type
IP67
―
Fibers
Amplifiers
P.58
P.63
FX-500
series
FX-100
series
INDEX
14
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Square Head Type
Compact, space-saving design brings clean installation
on the side of a conveyor belt.
As for lens compatible type fiber head, sensing range
becomes longer when a lens is attached to the thrubeam type fiber, spot detection is achieved in case of
the reflective type.
A lens equipped type fiber head is also available.
Oil resistant type is also available. Please refer to p.28
Compact, space-saving
Fiber can be installed at a minimum pitch of
M3: 6.5 mm 0.256 in or M4: 8.5 mm 0.335 in using
needle-nose pliers.
Wrench
Cylindrical
Type
M3 Type
Compact installation
Square head fiber heads can be installed cleanly on
the side of a conveyor belt. The design makes it less
likely for tools and other objects to catch on the fiber
cable during installation.
FT-R□ / FD-R□
Standard fiber
Needle-nose pliers
Sleeve
3.5 mm 0.138 in
Flat
Type
Clean installation!
Small
Spot
M4 Type
Tools and other
objects can catch
on the fiber cable.
Space is
required.
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
FT-R41W/R42W
Introducing square R1 mm (R0.039 in) (sharp bending) fiber
We now offer a sharp bending fiber featuring a low level of light fluctuations, even when bent at R1 mm R0.039 in.
It is also available with a lens capable of long-range sensing.
FT-R41W FT-R42W
FT-R42W (With lens)
Vacuumresistant
Liquid Leak /
Liquid Detection
R1 mm
R0.039 in
Lens
Fiber head
• Resistant to dust and particulate matter.
• Tip dimensions can be
shortened.
Fiber
Options
Full-protection type
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
High environmental
resistance
The head, nut, and washer
are made from rust-resistant
SUS304. The unbreakable
tough fiber with high
durability is covered in a
fluorine resin tube. The fiber
head is also covered with a
fluorine resin component,
achieving a high level of
environmental resistance.
FT-R60Y (Square head type M6 / thru-beam type)
Less susceptibility to oil
adhesion thanks to fluorine
resin
Fibers deliver stable
detection, since the sensing
part is sealed with fluorine
resin, which does not allow
oil penetration. Additionally,
the detection part features
a convex design made of
fluorine resin, achieving
lower friction than glass.
Amplifiers
FX-500
series
FX-100
series
INDEX
Resistant to oil and coolant
The fiber head and fiber cable are connected by
the “fastening and caulking” method without using
adhesives. This method eliminates concerns that
adhesives will absorb moisture in high-humidity
environments and damage the fiber. The enclosure
achieves IP68G
protection, so the
fiber can be installed
around metal
processing machines
shrouded in the oil
mist.
Test oil
Lubricating oil
M6
Non-water-soluble cutting oil
Fluorine resin
(PFA)
Stainless
steel
(SUS304)
Water-soluble cutting oil
Alcohol-based neutral detergent
Less susceptible to oil
adhesion than glass
Product
Velocite Oil No. 3
Yushiron Cut Abas KZ201
Yushiron Cut UH75
Syntilo 9954 (10% diluted)
Yushiroken S50N (2% diluted)
Super Teepol
*Yushiron and Yushiroken are registered trademarks of Yushiro
Chemical Industry Co., Ltd.
15
Cable-protection type FT-R44Y / FD-R61Y
FT-R44Y (Square head type M4 /
thru-beam type)
Compatible with
optional lens
Tough
Fiber
it can be used even in harsh environments
Stainless
steel
(SUS304)
M6
M4
New product
introduction
FD-R61Y (Square head type M6 /
cable will not harden or break, even if it is
splashed with oil.
Fiber
Selection
Guide
Model
The head, nut, and washer are made
from rust-resistant SUS304.
Fluorine resin
(PFA)
Choose
by shape/
application
LIST OF FIBERS
How to read
Model No.
Thru-beam type (one pair set)
Type
Model No.
(mm)
M3
M3
FT-R31
W5.5×H8×D16
Lens mountable
M4
FT-R43
M4
M4
Square head
W7×H9×D13.5
W7×H9×D13.9
With expansion lens
M4
Fiber
Bending cable
radius length
:
(mm)
Free-cut
R2
Bending
durability
R4
Bending
durability
FT-R41W
R1
2m
FT-R42W
W7×H9×D14.4
Cable-protection type
Compatible with lens
FT-R44Y
W7×H9.5×D15.5
M6
Full-protection type
W10×H11×D21.2
FT-R60Y
R4
Bending
durability
Sensing range (mm in) (Note 1)
FX-500 series
STD
270 10.630
HYPR
1,000 39.370
STD
720 28.346
HYPR
3,000 118.110
STD
800 31.496
HYPR
3,200 125.984
STD
2,200 86.614
HYPR
(Note2) 3,600 141.732
STD
720 28.346
HYPR
3,000 118.110
STD
2,100 82.677
HYPR
(Note2) 3,600 141.732
Beam axis
FX-101
dia.
Ambient
U-LG
Dimensions
(Upper
value)
(Fiber Core) Protection temp.
LONG
FX-102
(mm)
FAST
(Lower value)
H-SP
580 22.835
100 3.937
440 17.323
ø0.5
160 6.299 340 13.386
55 2.165
−55 to
IP67
+80 °C
1,600 62.992
210 8.268
1,100 43.307
430 16.929 640 25.197
130 5.118
P.51
ø1
1,800 70.866
250 9.843
1,400 55.118
460 18.110 710 27.953
150 5.906
−40 to
IP40
+60 °C
3,600 141.732(Note 2)
3,500 137.795 510 20.079
ø2.2
1,300 51.181 2,000 78.740
460 18.110
1,600 62.992
210 8.268
1,100 43.307
IP67
ø1
(Note 3)
430 16.929 640 25.197
130 5.118
−55 to
P.52
+80 °C
3,600 141.732(Note 2)
3,600 141.732(Note 2) 690 27.165
IP68G
ø3.5
1,260 49.606 1,890 74.409
400 15.748
Notes: 1) Note that the sensing range of t
2)
3)
Type
(mm)
Coaxial, Lens mountable
M3
Square head
M3
W5.5×H8×D16
Coaxial, Lens mountable
M3
W5.5×H8×D16
Coaxial, Lens mountable
M3
W5.5×H8×D16
Coaxial, Lens mountable
M3
Model No.
FD-R31G
FD-R32EG
FD-R34EG
FD-R33EG
W5.5×H8×D16
M4
M4
FD-R41
W7×H9×D13.5
Cable-protection type
M6
FD-R61Y
W10×H11×D15.5
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Type
Type
Chemical / Oilresistant
Fiber
Bending cable
radius length
:
(mm)
Free-cut
Sensing range (mm in) (Note 1, 2)
FX-500 series
R2
STD
170 6.693
2m HYPR
530 20.866
STD
45 1.772
HYPR
170 6.693
STD
38 1.496
R4 500mm HYPR
130 5.118
STD
19 0.748
HYPR
84 3.307
STD
R2
210 8.268
Bending
HYPR
durability
710 27.953
2m STD
R4
280 11.024
Bending
HYPR
durability
990 38.976
Bending
durability
Beam axis
FX-101
dia.
Ambient
U-LG
Dimensions
(Upper
value)
(Fiber Core) Protection temp.
LONG
FX-102
(mm)
FAST
(Lower value)
H-SP
310 12.205
Emitter
−55 to
45 1.772
260 10.236
ø0.5
85 3.346
150 5.906
+80 °C
27 1.063
110 4.331
92 3.622
30 1.181
9 0.354
20 0.787
68 2.677
Emitter
ø0.25
90 3.543
70 2.756
23 0.906
7 0.276
17 0.669
60 2.362
Emitter
ø0.175
44 1.732
33 1.299
11 0.433
3 0.118
Emitter
7 0.276
ø0.125
22 0.866
430 16.929
320 12.598
100 3.937
34 1.339
60 2.362
170 6.693
ø0.75
610 24.016
435 17.126
160 6.299
50 1.969
85 3.346
185 7.283
—
IP40
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
−40 to
+70 °C
Semi-custom
fibers
−20 to
P.63
+60 °C
Fiber
Dimensions
Thru-beam
Type
IP67
IP67
−55 to
+80 °C
(Note 3)
Type
Type
Others
Notes: 1) Note that the sensing range of t
2)
3)
FIBER OPTIONS
Amplifiers
P.42
P.43
FX-500
series
FX-100
series
INDEX
:
R4 mm R0.157 in or less) features.
ius: R10 mm R0.394 in
:
16
New product
introduction
Tough
Fiber
Cylindrical Type
Has a slender shape which can be mounted in narrow
locations using set screws.
Line up that includes ultra-thin fibers with ø0.25 mm tips.
Fiber
Selection
Guide
Model
How to read
Model No
Earlier models
comparison
table
FD-S31
FT-S32
Choose
by shape/
application
FT-S21/S21W/S31W
FD-S32/S31
● User-friendly, high quality fiber
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
● Improved centering accuracy and specularity
Stainless steel fittings are used for the fiber
head of all models.
● Clearly conforms to RoHS
● Can be used for secondary battery
● Improved mounting strength
Small
Spot
LIST OF FIBERS
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Thru-beam type (one pair set)
Type
Shape of fiber head
(mm)
Chemical / Oilresistant
ø1
ø1
Heatresistant
Vacuumresistant
6
Liquid Leak /
Liquid Detection
ø1.5
ø1·5
10
ø1.5
Fiber
Options
ø2·5
Cylindrical
ø2.5
8
ø3
Retroreflective
Type
Reflective
Type
Others
Amplifiers
ø3
ø4
Thru-beam
Type
Side-view Ultra-small diameter
10
Fiber
Dimensions
7RXJK
FT-S11
7RXJK
FT-S21
FT-S21W
With lens, Long sensing range
ø3
Semi-custom
fibers
10
Model No.
Narrow beam ø0.125mm
ø0.25 ø3
Sleeve part
cannot be bent.
5 15
Narrow beam ø0.25mm
Sleeve part
cannot be bent.
ø0.4 ø3
5 15
ø4
FT-S32
FT-S31W
25
R2
500 mm
Bending
durability
R1
R10
2m
Bending
durability
R1
7RXJK
FT-E13
7RXJK
FT-E23
7RXJK
FT-V40
3
Fiber
Bending cable
radius length
:
(mm)
Free-cut
R2
Bending
durability
1m
R4
Bending
durability
2m
Sensing range (mm in) (Note 1)
FX-500 series
STD
90 3.543
HYPR
350 13.780
STD
315 12.402
HYPR
1,350 53.150
STD
260 10.236
HYPR
990 38.976
STD
3,100 122.047
HYPR
(Note 2) 3,600 141.732
STD
800 31.496
HYPR
3,300 129.921
STD
15 0.591
HYPR
52 2.047
STD
75 2.953
HYPR
270 10.630
STD
3,500 137.795
HYPR
(Note 2) 3,600 141.732
U-LG
LONG
FAST
H-SP
210 8.268
160 6.299
60 2.362
19 0.748
770 30.315
550 21.654
210 8.268
70 2.756
590 23.228
440 17.323
150 5.906
53 2.087
3,600 141.732(Note 2)
3,600 141.732(Note 2)
1,800 70.866
600 23.622
1,900 74.803
1,400 55.118
490 19.291
160 6.299
30 1.181
24 0.945
8 0.315
2 0.079
160 6.299
125 4.921
42 1.654
13 0.512
3,600 141.732(Note 2)
3,600 141.732(Note 2)
2,400 94.488
850 33.465
FX-101 Beam axis
(Upper value) dia.
FX-102 (mm)
(Lower value)
40 1.575
90 3.543 ø0.25
Beam axis
position/
Ambient
Inclination Protection
Dimensions
temp.
of beam
axis
―
150 μm
/±2°
130 5.118
340 13.386
–55 to
+80 °C
IP67
ø0.5
150 μm
/±3°
80 3.150
240 9.449
1,100 43.307
3,000 118.110
ø2
―
260 10.236
720 28.346
ø1
150 μm
/±3°
6 0.236
19 0.748 ø0.125
―
22 0.866 ø0.25
80 3.150
―
1,000 39.370
3,100 122.047
ø2.5
–40 to
P.52
+60 °C
IP40
–40 to
+70 °C
–40 to
+60 °C
IP67
–40 to
P.49
+70 °C
―
IP50
–40 to
P.53
+60 °C
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
FX-500
series
FX-100
series
INDEX
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
17
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Reflective type
ø1·5
Type
Shape of fiber head
(mm)
Model No.
7RXJK
ø1.5
FD-S21
10
7RXJK
ø3
FD-S32
15
ø3
Cylindrical
ø3
FD-S32W
15
7RXJK
ø3
FD-S31
10
Coaxial
ø3
FD-S33GW
ø3
ø1·5
Ultra-small diameter
15
ø1.5 ø0.48
15 3
ø0.63
15
5
Sleeve part cannot be bent.
FD-E23
Beam axis
position/
Ambient
Inclination Protection
Dimensions
temp.
of beam
(Lower value) axis
Sensing range (mm in) (Note 1, 2)
FX-101
U-LG
(Upper value)
LONG
FX-500 series
FX-102
FAST
H-SP
130 5.118
110 4.331
37 1.457
11 0.433
STD
80 3.150
HYPR
190 7.480
STD
420 16.535
HYPR
1,200 47.244
STD
270 10.630
HYPR
900 35.433
790 31.102
660 25.984
120 4.724
220 8.661 345 13.583
75 2.953
630 24.803
430 16.929
150 5.906
45 1.772
80 3.150
230 9.055
―
STD
125 4.921
HYPR
515 20.276
290 11.417
220 8.661
80 3.150
25 0.984
35 1.378
140 5.512
150 μm
/±3°
R1
STD
150 5.906
HYPR
670 26.378
340 13.386
280 11.024
90 3.543
25 0.984
45 1.772
140 5.512
―
29 1.142
25 0.984
7 0.276
2 0.079
5 0.197
15 0.591
R4
STD
12 0.472
HYPR
50 1.969
STD
55 2.165
HYPR
170 6.693
R2
Bending
durability
1m
R4
Bending
durability
R1
R2
2m
Bending
durability
FD-E13
Sleeve part cannot be bent.
ø3
Fiber
Bending cable
radius length
:
(mm)
Free-cut
1m
120 4.724
80 3.150
30 1.181
9 0.354
25 0.984
70 2.756
―
IP40
P.63
IP67
–40 to
+60 °C
–55 to
+80 °C
–40 to
+60 °C
―
Heatresistant
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
IP40
P.58
20 0.787
70 2.756
Chemical / Oilresistant
Liquid Leak /
Liquid Detection
P.64
―
Retroreflective
Type
Vacuumresistant
–55 to
+80 °C
150 μm
/±3°
Convergent
Reflective
Type
–40 to
+70 °C
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper.
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
18
New product
introduction
Tough
Fiber
Sleeve
It is suitable for sensing in narrow locations and sensing
minute objects because the fiber tip is a thin sleeve.
The 40 mm sleeve type can be bent in any direction.
Fiber
Selection
Guide
Model
FD-41S
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
FT-42S
FT-E13 / FT-E23 Ultra-small diameter fiber
Centering accuracy of 1/10 mm or less
Ultra-small diameter fibers with a compact head ensure precision centering accuracy* to stably detect minute parts.
A
B
C
Threaded
Type
Square Head
Type
Dimensions UNCLEAR
Cylindrical
Type
Sleeve
Flat
Type
* Tolerance of A + Tolerance of B + Tolerance of C = ±0.09 mm
Dimensions unclear
Screw
Dimensions CLEAR
Example: FT-E13
Dimensions unclear
ø3 mm+0.05 +0.002
ø0.118 in 0
Previous
general
fiber
New
standard
fiber
Extra clearance needs to be added when
designing and machining the mounting hole
due to unclear dimensions.
As a result, mounting variation increases
and the beam axis deviates, resulting in a
decrease in sensing accuracy or causing the
sleeve to bend or break.
Highly accurate design and machining are
possible due to clear mounting hole dimensions.
As a result, mounting variation is minimal,
improving sensing accuracy. In addition to this, as
the beam axis alignment is not affected when the
fiber is changed, readjustment is not necessary.
ø0.5 mm+0.05 +0.002
ø0.020 in 0
Screw
Dimensions clear
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Minute sensing only possible with ultra small fiber
Detection of fine-pitch connector pins
Fiber
Options
FT-E13
Detection of tiny chips
Ultra-small diameter fiber
with ø0.125 mm ø0.005 in
beam axis is able to detect
the insertion or bending of
fine-pitch connector pins.
Fiber can be installed with
only the ø0.25 mm ø0.010
in sleeve close to the minute
section.
FT-E13
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Stainless steel fittings are used for the fiber
head of all models.
● Clearly conforms to RoHS
● Can be used for secondary battery
● Improved mounting strength
Application
FIBER OPTION
Fiber bender
Amplifiers
FX-500
series
FX-100
series
·FB-1
The fiber bender bends the
sleeve part of the fiber head
at the proper radius.
Note: Do not bend the sleeve part of any side-view type fiber or ultrasmall diameter head type fiber.
INDEX
19
LIST OF FIBERS
New product
introduction
Thru-beam type (one pair set)
Shape of fiber head
(mm)
Type
7RXJK
M3
FT-31S
10
Sleeve 40mm
M4
Narrow beam ø0.125mm
ø0.25
Sleeve part
cannot be bent.
FT-42S
12
FT-E13
7RXJK
ø0.4 ø3
Sleeve part
cannot be bent.
FT-E23
5 15
ø1
ø2
Cylindrical
Side-view
ø2
FT-V23
20 15
ø1 ø2
FT-V25
15 15
ø1 ø2
ø2·5
R4
Bending
durability
R2
Bending
durability
R1
FT-V24W
15 15
ø1.5 ø2.5
7RXJK
1.3
FT-V30
Sleeve part
cannot be bent.
1m
2m
1
Sleeve part
cannot be bent.
Bending
durability
7RXJK
1
Sleeve part
cannot be bent.
2m
R2
7RXJK
1.1
Sleeve part
cannot be bent.
R4
Bending
durability
(Note 3)
7RXJK
ø3
5 15
Narrow beam ø0.25mm
R2
Bending
durability
(Note 3)
7RXJK
M4
ø1.48
ø3
Model No.
M3
ø0.88
Ultra-small diameter
Threaded
Sleeve 40mm
Sensing range (mm in) (Note 1, 2)
Beam
FX-101
Ambient
U-LG
Dimensions
axis dia. Protection
(Upper
value)
temp.
LONG
FX-500 series
(mm)
FX-102
FAST
(Lower value)
H-SP
Fiber
Bending cable
radius length
:
(mm)
Free-cut
20 15
R4
Bending
durability
STD
315 12.402
HYPR
1,220 48.031
STD
1,130 44.488
HYPR
(Note 2) 3,600 141.732
STD
15 0.591
HYPR
52 2.047
STD
75 2.953
HYPR
270 10.630
STD
450 17.717
HYPR
1,800 70.866
STD
240 9.449
HYPR
900 35.433
STD
110 4.331
HYPR
380 14.961
STD
680 26.772
HYPR
2,200 86.614
740 29.134
550 21.654
195 7.677
63 2.480
2,050 80.709
1,600 62.992
530 20.866
190 7.480
30 1.181
24 0.945
8 0.315
2 0.079
160 6.299
125 4.921
42 1.654
13 0.512
1,000 39.370
880 34.646
280 11.024
90 3.543
550 21.654
480 18.898
140 5.512
45 1.772
230 9.055
200 7.874
60 2.362
20 0.787
1,200 47.244
1,000 39.370
340 13.386
100 3.937
130 5.118
340 13.386
–55 to
+80 °C
P.48
ø1
–40 to
+70 °C
ø0.25
160 6.299
400 15.748
ø0.75
P.49
P.52
–55 to
+80 °C
95 3.740
260 10.236
–40 to
+60 °C
35 1.378
90 3.543
P.53
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
M3
Ultra-small
diameter
Shape of fiber head
(mm)
M3
ø0.8
FD-EG30S
15
Sleeve 40 mm
7RXJK
M4
Threaded
M4
FD-41S
ø1.48
Sleeve 40 mm
M4
FD-41SW
ø1.48
12
M6
Sleeve 40 mm
ø1·5
FD-61S
ø2.5
ø1.5 ø0.48
R4
1m
ø3
R1
(Note 3)
2m
1m
Sleeve part cannot be bent.
ø3
Small diameter
15
15
ø3 ø1.5
7RXJK
FD-V30
2
Sleeve part cannot be bent.
15
ø3
15
ø1.5
FD-V30W
2
R2
Bending
durability
R1
Sleeve part cannot be bent.
ø5
15
ø5
7RXJK
20
ø2
Sleeve part cannot be bent.
2.3
FD-V50
R4
Bending
durability
STD
50 1.969
HYPR
170 6.693
STD
125 4.921
HYPR
515 20.276
STD
80 3.150
HYPR
330 12.992
HYPR
FD-E23
5
Sensing range (mm in) (Note 1, 2)
FX-101
U-LG
(Upper value) Protection
LONG
FX-500 series
FX-102
STD
R4
Bending
durability
(Note 3)
R4
ø0.63
15
R2
Bending
durability
(Note 3)
FD-E13
15 3
Sleeve part cannot be bent.
ø3
Ultra-small diameter
Cylindrical
7RXJK
M6
15
Side-view
Model No.
Fiber
Bending cable
radius length
:
(mm)
Free-cut
Sleeve part cannot be bent.
12
Flat
Type
Small
Spot
–55 to
+80 °C
ø1.0
Square Head
Type
Sleeve
IP30
ø0.5
Threaded
Type
Cylindrical
Type
Reflective type
Sleeve 15 mm
Fibers
Super
Quality
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
3) Bending radius of sleeve part is R10 mm R0.394 in or more.
Type
How to read
Model No.
ø0.125
22 0.866
80 3.150
180 7.087
480 18.898
Choose
by shape/
application
Earlier models
comparison
table
IP67
6 0.236
19 0.748
Fiber
Selection
Guide
Model
ø0.5
300 11.811
800 31.496
Tough
Fiber
2m
420 16.535
1,200 47.244
STD
12 0.472
HYPR
50 1.969
STD
55 2.165
HYPR
170 6.693
STD
65 2.559
HYPR
240 9.449
STD
20 0.787
HYPR
80 3.150
STD
120 4.724
HYPR
370 14.567
FAST
(Lower value)
H-SP
110 4.331
80 3.150
20 0.787
30 1.181
70 2.756
9 0.354
IP40
Chemical / Oilresistant
Ambient
temp.
Dimensions
–40 to
+70 °C
P.59
290 11.417
220 8.661
80 3.150
25 0.984
35 1.378
140 5.512
–55 to
+80 °C
180 7.087
140 5.512
45 1.772
12 0.472
15 0.591
60 2.362
–40 to
+60 °C
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
P.56
IP67
790 31.102
660 25.984
130 5.118
220 8.661 360 14.173
75 2.953
–55 to
+80 °C
29 1.142
25 0.984
7 0.276
2 0.079
5 0.197
15 0.591
120 4.724
80 3.150
30 1.181
9 0.354
20 0.787
70 2.756
–40 to
+70 °C
130 5.118
120 4.724
35 1.378
14 0.551
25 0.984
75 2.953
–55 to
+80 °C
40 1.575
30 1.181
10 0.394
2 0.079
6 0.236
20 0.787
–40 to
+60 °C
220 8.661
210 8.268
75 2.953
25 0.984
40 1.575
100 3.937
Semi-custom
fibers
P.57
Fiber
Dimensions
Thru-beam
Type
–40 to
+60 °C
IP40
P.58
Retroreflective
Type
Reflective
Type
Others
P.64
IP30
–55 to
+80 °C
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper.
3) Bending radius of sleeve part is R10 mm R0.394 in or more.
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
Amplifiers
FX-500
series
P.65
FX-100
series
INDEX
20
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Flat Type
Since it has a thin, rectangular shape, it can be installed
in narrow locations. It is also a fiber with good workability
and can be mounted directly with screws.
FT-Z30H
FT-Z30E
FT-Z30
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
1 point mounting
The sensor can be mounted on 1 point with either M2
screw or M3 screw. Metal sleeve in the enclosure helps to
be tightened firmly even with a single screw.
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Space-saving
installation
Fiber guide system contributes to
space-saving
FT-Z□HBW and FD-Z□HBW is equipped with a fiber guide
feature. This enables to mount either way of top sensing
and side sensing.
M2 screw
Top Sensing
Side Sensing
FD-Z20HBW
10 mm
0.394 in
2 mm
0.079 in
Boss
Equipped with metal sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
LIST OF FIBERS
Thru-beam type (one pair set)
Type
Vacuumresistant
Shape of fiber head
(mm)
Top sensing W3 × H8 × D12
Model No.
7RXJK
FT-Z30H
Liquid Leak /
Liquid Detection
Side sensing W3 × H12 × D8
FX-500 series
R1
7RXJK
R2
STD
(Note 2)
STD
Bending
durability
HYPR
(Note 2)
2m
Side sensing W3 × H12 × D8
FT-Z30EW
R1
STD
HYPR
(Note 2)
Front sensing
Thru-beam
Type
W8.5 × H12 × D3 7RXJK
FT-Z30
Flat
Fiber
Dimensions
Front sensing
Retroreflective
Type
W8.5 × H12 × D3
Front sensing
W10 × H7 × D2
Others
Bending
durability
FX-100
series
INDEX
With boss
FX-500
series
HYPR
(Note 2)
STD
FT-Z30W
HYPR
FT-Z20W
1m
Fiber bending type
Amplifiers
STD
R2
(Note 2)
Reflective
Type
W2 × H10 × D10
Front sensing
W14 × H7 × D3.5
FT-Z20HBW
W3.5 × H14 × D11
R1
FT-Z40W
2m
Fiber bending type
FT-Z40HBW
U-LG
LONG
FAST
H-SP
Beam
FX-101
Ambient
(Upper value) axis dia. Protection temp. Dimensions
(mm)
FX-102
(Lower value)
R2
Bending
durability
FT-Z30HW
FT-Z30E
Semi-custom
fibers
Sensing range (mm in) (Note 1)
HYPR
Top sensing W3 × H8 × D12
Fiber
Options
Fiber
Bending cable
radius length
:
(mm)
Free-cut
3,500 137.795
3,600 141.732
3,500 137.795
3,600 141.732
3,400 133.858
3,600 141.732
2,100 82.677
3,600 141.732
1,500 59.055
3,600 141.732
STD
620 24.409
HYPR
(Note 2) 1,600 62.992
STD
260 10.236
HYPR
1,100 43.307
STD
1,500 59.055
HYPR
(Note 2) 3,600 141.732
STD
800 31.496
HYPR
3,300 129.921
3,600 141.732(Note 2)
3,600 141.732(Note 2) 1,400 55.118
2,600 102.362 3,200 125.984
810 31.890
2×3
3,600 141.732(Note 2)
3,600 141.732(Note 2) 1,200 47.244
2,400 94.488 3,200 125.984
740 29.134
3,600 141.732(Note 2)
3,600 141.732(Note 2) 1,400 55.118
2,000 78.740 2,600 102.362
630 24.803
3,600 141.732(Note 2)
710 27.953
3,600 141.732(Note 2)
1,200 47.244 2,300 90.551
410 16.142
ø2
3,300 129.921
3,200 125.984
540 21.260
1,000 39.370 1,800 70.866
280 11.024
1,500 59.055
1,100 43.307
280 11.024
420 16.535
730 28.740 ø1.5
130 5.118
670 26.378
570 22.441
100 3.937
180 7.087
320 12.598 ø0.5
55 2.165
3,300 129.921
2,300 90.551
410 16.142
900 35.433 1,200 47.244 ø1.5
290 11.417
1,900 74.803
1,400 55.118
260 10.236
ø1
490 19.291
720 28.346
160 6.299
P.54
P.53
P.54
IP40
P.53
–40 to
+60 °C
P.54
P.53
IP67
IP40
P.54
IP67
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
21
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Reflective type
Type
Shape of fiber head
(mm)
Model No.
Bending
radius
(mm)
Fiber
cable
length
:
Free-cut
Front sensing
FD-Z20W
W10 × H7 × D2
1m
With boss
Flat
Fiber bending type
FD-Z20HBW
W2 × H10 × D10
R1
Front sensing
FD-Z40W
W14 × H7 × D3.5
2m
Fiber bending type
FD-Z40HBW
W3.5 × H14 × D11
Retroreflective
Type
Sensing range (mm in) (Note 1, 2)
FX-101
Ambient
U-LG
(Upper value) Protection temp. Dimensions
LONG
FX-500 series
FX-102
FAST
(Lower value)
H-SP
150 5.906
STD
2 to 32
1 to 65 0.039 to 2.559
130 5.118 0.079 to 1.260
IP40
2 to 45 0.079 to 1.772
1 to 80
HYPR
5 to 13 0.197 to 0.512 0.039 to 3.150
260 10.236
1 to 210 0.039 to 8.268
STD
2 to 30
2 to 85 0.079 to 3.346 1 to 180 0.039 to 7.087 0.079 to 1.181
2
to
55
0.079
to
2.165
1 to 90 IP67
HYPR
3 to 15 0.118 to 0.591 0.039 to 3.543
1 to 340 0.039 to 13.386
–40 to
P.65
+60 °C
440 17.323
STD
1 to 74
190 7.480
390 15.354 0.039 to 2.913
1 to 120 0.039 to 4.724
200 IP40
HYPR
2 to 35 0.079 to 1.378
790 31.102
7.874
540 21.260
STD
1 to 90
260 10.236
470 18.504 0.039 to 3.543
1
to
160
0.039
to
6.299
0.5 to 240 IP67
HYPR
2 to 50 0.079 to 1.969 0.020 to 9.449
760 29.921
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper.
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
22
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Small Spot
Sensing of minute objects can be performed by
combining the fiber and spot lens. The spot diameter
can also be changed.
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Applications
Packing detection
Number of IC pins checking
FD-42G/42GW
FD-EG31
Fibers
Super
Quality
Discrimination of 0603 chip direction
FX-MR6 (lens)
+
FD-EG31 (fiber)
IC
FX-MR5
FX-MR3
Threaded
Type
Square Head
Type
Cylindrical
Type
Because it’s a side-view type, it can
be mounted even in narrow spaces.
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Three optional lenses for reflective type fiber are available.
Perfect for chip component detection applications.
Finest spot lens FX-MR7
Parallel light lens FX-MR9
About 3 times more light received (compared to previous models)
Long-range parallel light
Since there is a large difference
in the amount of light received
in applications such as direction
detection, it is easy to set a threshold
that will allow stable detection.
Additionally, these products offer an
S/N ratio that is 1.3 times better than
previous models.
Depending on the fiber with which it
is used, this lens creates parallel light
with a spot diameter of approximately
ø4 mm ø0.157 in at a sensing range
of 0 to 30 mm 0 to 1.181 in.
Typical FX-501 erformance (STD mode)
Fiber
Options
Semi-custom
fibers
FX-MR7 / MR8 / MR9
White
Black
FX-MR7 + FD-R33EG
3,200 digits
1,030 digits
FX-MR6 (compared to previous models)
+ FD-R33EG
1,000 digits
435 digits
Zoom lens FX-MR8
All models
Tightening torque 5 times (compared to previous models)
The standard aluminum body has been changed to
stainless steel (SUS 303) to reduce the likelihood of
damage from over-tightening.
Fiber
Dimensions
Variable spot diameter
Standard lens outer diameter of ø4.3 mm (ø0.169 in)
Thru-beam
Type
Spot diameters ranging from ø0.4 to
ø3.5 mm ø0.016 to ø0.138 in can be
achieved by combining the lens with a
variety of fibers.
Use of the same mounting hardware across the
product line means less inventory and lower costs.
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
23
LIST OF FIBERS
New product
introduction
High precision fiber & spot lens
Shape of head
(mm)
Dimensions
Designation
Spot diameter
(mm in) (Note)
16
P.68
ø4
P.68
Lens
Distance to
focal point
Ambient
(mm in) (Note) Model No. temp.
Applicable fibers
Fiber cable Bending
Ambient
Model No.
length
radius Protection
Dimensions
temp.
: Free-cut (mm)
ø0.1 ø0.004
FD-EG31
ø0.2 ø0.008
FD-EG30
500 mm
7RXJK
7±0.5
0.276±0.020
FX-MR6
–20 to
+60 °C
ø0.4 ø0.016
P.68
ø4
P.68
FD-42GW
ø0.15 ø0.006
FD-EG31
ø0.3 ø0.012
FD-EG30
Bending
durability
1m
500 mm
7RXJK
FX-MR3
ø0.5 ø0.020
7RXJK
20.2
Pinpoint spot
lens
ø4
ø0.5 ø0.020
Zoom lens
(Side-view type)
ø7.1
P.67
W6.3 × H20.3
× D10.3
FX-MR1
–40 to
+70 °C
P.68
ø0.7 to ø2.0
ø0.028 to
ø0.079
Approx.18.5 to 43
Approx. 0.728 to
1.693
ø0.5 to ø3.0
ø0.020 to
ø0.118
Approx.13 to 30
Approx. 0.512 to
1.181
1m
7RXJK
Bending
durability
FD-42GW
7RXJK
FX-MR2
–40 to
+70 °C
FD-42G
2m
FD-42GW
–40 to
+70 °C
–40 to
+60 °C
P.57
FD-42G
R2
–55 to
+80 °C
R1
–40 to
+60 °C
R2
–55 to
+80 °C
R1
FD-42GW
Type
Spot diameter
(mm in) (Note)
Lens
Shape (mm in)
Model No.
Dimensions
Shape
ø0.1 ø0.004
approx.
ø0.15 ø0.006
approx.
Finest spot
lens
ø0.2 ø0.008
approx.
7 ± 0.5
0.276 ± 0.020 ø5 ø0.197
15.3
0.602
FX-MR7
ø0.4 ø0.016
approx.
Type
Spot diameter
(mm in) (Note)
P.68
Lens
Sensing
range
(mm in) (Note)
Shape
(mm in)
ø0.4 to ø2.0 ø0.016 to ø0.079 approx.
Zoom lens
ø0.4 to ø2.2 ø0.016 to ø0.087 approx.
10 to 30
ø5 ø0.197
ø0.5 to ø2.5 ø0.020 to ø0.098 approx. 0.394 to1.181
ø0.8 to ø3.5 ø0.031 to ø0.138 approx.
Parallel light
lens
ø4.0 ø0.157 approx.
Model No.
15
0.591
FX-MR8
P.68
10
0.394
0 to 30
0 to 1.181
FX-MR9
ø5 ø0.197
P.68
Emitting fiber
core (mm in)
Fiber
Emitting fiber
core (mm in)
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Flat
Type
Narrow
Beam
Wide
Beam
P.57
–40 to
+60 °C
Square head type M3, Reflective type fiber & spot lens
Distance to
focal point
(mm in) (Note)
How to read
Model No.
Small
Spot
–55 to
+80 °C
–40 to
+60 °C
Bending
durability
Choose
by shape/
application
Sleeve
–55 to
P.56
+80 °C
R1
Bending
durability
7RXJK
FX-MR5
R2
R2
FD-42G
P.67
27.1
Zoom lens
6±1
0.236±0.039
IP40
–55 to
+80 °C
R2
Bending
durability
FD-32GX
P.68
R4
R1
2m
Model
Earlier models
comparison
table
–20 to
P.59
+60 °C
–40 to
P.58
+70 °C
R2
FD-42GW
Fiber
Selection
Guide
–55 to
P.56
+80 °C
R2
Bending
durability
FD-42G
FD-32G
P.57
R2
FD-32GX
–40 to
+70 °C
–40 to
+60 °C
R1
2m
7RXJK
7.5±0.5
0.295±0.020
–55 to
+80 °C
Bending
durability
FD-42G
P.68
15
R4
R2
FD-32G
Finest spot
lens
–20 to
P.59
+60 °C
–40 to
P.58
+70 °C
Tough
Fiber
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Model No.
ø0.125 ø0.005
FD-R33EG
ø0.125 ø0.005
FD-EG31
ø0.175 ø0.007
FD-R34EG
ø0.25 ø0.010
FD-R32EG
ø0.25 ø0.010
FD-EG30
ø0.5 ø0.020
FD-R31G
ø0.5 ø0.020
FD-32G
ø0.5 ø0.020
FD-32GX
ø0.5 ø0.020
FD-42G
ø0.5 ø0.020
FD-42GW
Applicable fibers
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Model No.
ø0.125 ø0.005
FD-R33EG, FD-EG31
ø0.175 ø0.007
FD-R34EG
ø0.25 ø0.010
FD-R32EG, FD-EG30
ø0.5 ø0.020
FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW
ø0.125 ø0.005
FD-R33EG, FD-EG31
ø0.175 ø0.007
FD-R34EG
ø0.25 ø0.010
FD-R32EG, FD-EG30
ø0.5 ø0.020
FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW
Note: Spot diameter, distance to focal point and sensing range are specified for FX-500/FX-100 series.
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
Amplifiers
FX-500
series
FX-100
series
INDEX
24
New product
introduction
Tough
Fiber
Narrow Beam
Since the beam is narrow, it has a feature by which it is
not easily affected by surrounding obstacles even in
long distances.
Fiber
Selection
Guide
Model
Choose
by shape/
application
Applications
How to read
Model No
Detection of a transparent tube
Aperture angle 3°
Mapping of a wafer
Detection of a wafer
Earlier models
comparison
table
FR-KZ50H
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Thru-beam type (one pair set)
Type
Shape of fiber head
(mm)
Aperture angle 2°
ø3.5 ø3.7
Flat
Type
Convergent
Reflective
Type
Narrow beam
Wide
Beam
Aperture angle 2° ø4
3
Retroreflective
Type
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
filter
With
Wafer mapping polarizing
Narrow beam
Semi-custom
fibers
Type
Side sensing Top sensing
Fiber
Options
INDEX
Long
range
Amplifiers
FX-100
series
7RXJK
FT-KV40
STD
Bending
durability
STD
2m
R1
STD
3,600 141.732
(Note 2)
3,600 141.732
(Note 2)
3,600 141.732
(Note 2)
3,600 141.732
HYPR
(Note 2)
7RXJK
FT-KV26
20
STD
R2
3,600 141.732
(Note 2)
HYPR
25
Aperture angle 3° 1.5 × 2
(Note 2)
HYPR
R2
25
FT-KV40W
FX-500 series
3,600 141.732
710 27.953
HYPR
2,500 98.425
Bending
durability
Beam
FX-101 axis
(Upper value) dia.
FX-102 (mm)
(Lower value)
U-LG
LONG
FAST
H-SP
3,600 141.732(Note 2) 2,200 86.614
3,600 141.732(Note 2) 3,600 141.732
ø2.2
3,600 141.732(Note 2)
(Note 2)
1,200 47.244
3,600 141.732(Note 2)
3,600 141.732(Note 2)
3,600 141.732(Note 2)
1,200 47.244 2,200 86.614
3,600 141.732 ø2.5
3,600 141.732(Note 2)
(Note 2)
(Note
2)
3,600 141.732
3,100 122.047
940 37.008
1,600 62.992
1,200 47.244
135 5.315
440 17.323 560 22.047 ø1
160 6.299
Beam axis
position/
Ambient
Inclination Protection
Dimensions
temp.
of beam
axis
―
IP40
–40 to
P.51
+60 °C
±0.8°
IP30
X±1°
Z±0.5°
Shape of fiber head
(mm)
Model No.
W5.2 × H9.5 × D16
FR-Z50HW
Fiber
Bending cable
radius length
:
(mm)
Free-cut
R1
W30 × H30 × D0.5
Sensing range (mm in) (Note 1, 3)
U-LG
LONG
FAST
H-SP
STD
100 to 1,400 3.937 to 55.118
100 to 990 3.937 to 38.976 100 to 1,200 3.937 to 47.244
100 to 780 3.937 to 30.709
HYPR
100 to 1,900 3.937 to 74.803 100 to 490 3.937 to 19.291
FX-500 series
FX-101
Ambient
(Upper value) Protection temp. Dimensions
FX-102
(Lower value)
100 to 550
–25 to
3.937 to 21.654
100 to 830 IP40 +55 °C
3.937 to 32.677
W7.5 × H2.2 × D11.2
Aperture
angle 3°
(emitter)
7RXJK
FR-KZ50H
W10.6 × H28 × D10.1
W9.5 × H25 × D5.2
15 to 310 0.591 to 12.205
HYPR
15 to 570 0.591 to 22.441
FR-KZ22E
W4 × H2 × D21.5
W5.2 × H9.5 × D21
STD
7RXJK
R2
15 to 460 0.591 to 18.110
15 to 410 0.591 to 16.142
15 to 220 0.591 to 8.661
15 to 100 0.591 to 3.937
15 to 200
0.591 to 7.874
15 to 360
0.591 to 14.173
2m
Bending
durability
STD
20 to 300 0.787 to 11.811
HYPR
20 to 1,000 0.787 to 39.370
7RXJK
FR-KZ50E
P.55
–40 to
IP30
+60 °C
20 to 800 0.787 to 31.496
20 to 400 0.787 to 15.748
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200
0.787 to 7.874
20 to 350
0.787 to 13.780
W28 × H10.6 × D10.1
Reflective type
Type
FX-500
series
FT-KS40
Sensing range (mm in) (Note 1)
Retroreflective type
Vacuumresistant
Liquid Leak /
Liquid Detection
3
Fiber
Bending cable
radius length
:
(mm)
Free-cut
7RXJK
Aperture angle 2° ø4
2
Chemical / Oilresistant
Heatresistant
Model No.
20
Side-view
Narrow
Beam
FR-KZ22E
LIST OF FIBERS
Sleeve
Small
Spot
FT-KV40
Shape of fiber head
(mm)
Model No.
Fiber
Bending cable
radius length
:
(mm)
Free-cut
Sensing range (mm in) (Note1)
FX-500 series
STD
W5.2 × H9.5 × D16
FD-Z50HW
R1
2m
HYPR
10 to 650 0.394 to 25.591
10 to 2,500 0.394 to 98.425
U-LG
LONG
FAST
H-SP
10 to 1,100 0.394 to 43.307
10 to 1,000 0.394 to 39.370
10 to 410 0.394 to 16.142
15 to 130 0.591 to 5.118
FX-101
Ambient
(Upper value) Protection temp. Dimensions
FX-102
(Lower value)
10 to 200
–40 to
0.394 to 7.874
10 to 530 IP40 +60 °C P.65
0.394 to 20.866
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
3) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.
Refer to P.27 or 38 for the sensing range when FR-Z50HW is used in combination with a reflector (optional).
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
25
Wide Beam
New product
introduction
Tough
Fiber
Senses a workpiece with indefinite shape or position in
the wide beam without missing. It can also be used to
discriminate shape.
Fiber
Selection
Guide
FT-A11
Model
Choose
by shape/
application
How to read
Model No.
Applications
Sensing tiny moving objects
Inspecting screw height Control the amount of meandering Confirming presence of slit mask
FD-A16
Spot size
2 × 15mm
(by a distance of 15mm)
FT-A11
FT-A32
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Type :
With slit mask
Type :
Without slit mask
Small
Spot
Thru-beam type (one pair set)
Type
Sensing width
32mm
Model No.
7RXJK
FT-A32
W5 × H69 × D20
Fiber
Bending cable
radius length
:
(mm)
Free-cut
R2
Bending
durability
Wide beam
W4.2 × H31 × D13.5
Allows flexible wiring
Sensing width
11mm
R1
Array
W5 × H15 × D15
(Note 2)
HYPR
(Note 2)
7RXJK
FT-A11
FT-A11W
R2
2m
Bending
durability
R1
W4.2 × H31 × D13.5
Sensing width
5.5mm
(Note 2)
(Note 2)
STD
FT-A32W
7RXJK
FT-AL05
R2
Bending
durability
U-LG
LONG
FAST
H-SP
FX-500 series
HYPR
W5 × H69 × D20
Sensing width
11mm
Sensing range (mm in) (Note 1)
STD
Allows flexible wiring
Sensing width
32mm
STD
3,600 141.732
3,600 141.732
3,600 141.732
3,600 141.732
3,600
3,600
3,600
3,600 141.732
Beam
axis
dia.
(mm)
Protection
Ambient
Dimensions
temp.
Chemical / Oilresistant
–40 to
+60 °C
2,100 82.677 3,600 141.732
Heatresistant
(Note 2)
3,600 141.732(Note 2)
3,600 141.732(Note 2)
3,600 141.732(Note 2)
3,000 118.110
3,600 141.732 3.2 × 32
(Note 2)
Vacuumresistant
–40 to
+55 °C
IP40
1,900 74.803
3,600 141.732
Liquid Leak /
Liquid Detection
P.49
–40 to
+70 °C
(Note 2)
Fiber
Options
2.2 × 11
1,700 66.929
3,400 133.858
250 9.843
660 25.984 0.25 × 5.5
–40 to
+55 °C
Semi-custom
fibers
–55 to
+80 °C
Fiber
Dimensions
Thru-beam
Type
Reflective type
Array
Wide
beam
Type
Model No.
7RXJK
FD-A16
W7 × H15 × D30
7RXJK
FD-AL11
W5 × H20 × D20
Fiber
Bending cable
radius length
:
(mm)
Free-cut
R4
Bending
durability
R2
Bending
durability
2m
Retroreflective
Type
Sensing range (mm in) (Note 1, 2)
FX-101
FX-500 series
STD
200 7.874
HYPR
Cannot use
STD
320 12.598
HYPR
670 26.378
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
141.732(Note 2)
141.732(Note 2)
141.732(Note 2)
3,600 141.732(Note 2)
3,600 141.732(Note 2)
3,600 141.732(Note 2)
HYPR
(Note 2) 3,600 141.732
1,100 43.307
STD
3,600 141.732(Note 2)
(Note 2) 3,600 141.732
3,600 141.732(Note 2)
3,600 141.732(Note 2)
HYPR
(Note 2) 3,600 141.732
1,300 51.181
STD
1,550 61.024
860 33.858
1,500 59.055
500 19.685
HYPR
170 6.693
2,300 90.551
(Note 2)
FX-101
(Upper value)
FX-102
(Lower value)
Narrow
Beam
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
Shape of fiber head
(mm)
Sleeve
Flat
Type
LIST OF FIBERS
Shape of fiber head
(mm)
Cylindrical
Type
Ambient
U-LG
(Upper value) Protection temp.
LONG
FX-102
FAST
(Lower value)
H-SP
200 7.874
–40 to
200 7.874
120 4.724
140 5.512
240 9.449
+60 °C
75 2.953
IP40
530 20.866
–55 to
510 20.079
100 3.937
180 7.087
285 11.220
+80 °C
50 1.969
Dimensions
P.58
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper.
INDEX
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
26
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Convergent Reflective Type
It is a fiber in which the sensing distance is limited to a
specific range so it is not easily affected by the
background. It is effective when a workpiece is accumulated or when the background is near.
Applications
Detecting a passing glass
LCD transportation
Mounting in handling arms
Mapping fiber
FD-L32H
Seating
Fibers
Super
Quality
confirmation fiber
FD-L11
FD-L30A
Threaded
Type
FD-L12W
Square Head
Type
Cylindrical
Type
Alignment fiber
FD-L22A/L30A/L31A
Sleeve
Flat
Type
Small
Spot
LIST OF FIBERS
Reflective type
Narrow
Beam
Wide
Beam
Type
Convergent
Reflective
Type
Shape of fiber head
(mm)
Model No.
Mapping
Retroreflective
Type
FD-L32H
Chemical / Oilresistant
W25 × H7.3 × D30
7RXJK
Alignment
Heatresistant
FD-L30A
Vacuumresistant
W20 × H29 × D3.8
Alignment
Liquid Leak /
Liquid Detection
7RXJK
FD-L31A
Fiber
Options
Semi-custom
fibers
Glass substrate detection
W23.5 × H29 × D4.5
Fiber
Dimensions
Alignment
FD-L22A
W17 × H29 × D3.8
Seating confirmation
7RXJK
FD-L23
W12 × H19 × D3
7RXJK
FD-L10
7RXJK
FD-L21
Reflective
Type
W24 × H21 × D4
Others
FD-L21W
FX-500
series
FX-100
series
INDEX
Ultlasmall
Amplifiers
General
purpose
W24 × H21 × D4
7RXJK
0 to 43 0 to 1.693
0 to 40
0 to 1.575
0 to 50
0 to 1.969
Bending
durability
4 to 33 0.157 to 1.299
HYPR
3 to 35 0.118 to 1.378
4 to 33 0.157 to 1.299
4 to 33 0.157 to 1.299
4 to 32 0.157 to 1.260
5 to 25 0.197 to 0.984
5 to 30
0.197 to 1.181
4 to 33
0.157 to 1.299
R2
STD
0 to 24 0 to 0.945
HYPR
0 to 31 0 to 1.220
0 to 28 0 to 1.102
0 to 27 0 to 1.063
0 to 24 0 to 0.945
0 to 18 0 to 0.709
0 to 19
0 to 0.748
0 to 25
0 to 0.984
0 to 30 0 to 1.181
0 to 30 0 to 1.181
0 to 28 0 to 1.102
1.5 to 24 0.059 to 0.945
0 to 28
0 to 1.102
0 to 30
0 to 1.181
0 to 10.5 0 to 0.413
0 to 10 0 to 0.394
0 to 9 0 to 0.354
0 to 8 0 to 0.315
0 to 8
0 to 0.315
0 to 9
0 to 0.354
0 to 5.5 0 to 0.217
0 to 5.5 0 to 0.217
0 to 4.5 0 to 0.177
0 to 4 0 to 0.157
0 to 4.5
0 to 0.177
0 to 5.5
0 to 0.217
STD
1.5 to 16 0.059 to 0.630
HYPR
1 to 19 0.039 to 0.748
1 to 18 0.039 to 0.709
1 to 18 0.039 to 0.709
2 to 15 0.079 to 0.591
3 to 12 0.118 to 0.472
3 to 15
0.118 to 0.591
1.5 to 16
0.059 to 0.630
STD
3 to 14 0.118 to 0.551
HYPR
1.5 to 15 0.059 to 0.591
STD
23 0.906
HYPR
45 1.772
STD
8 0.315
HYPR
14 0.551
2 to 15 0.079 to 0.591
2 to 15 0.079 to 0.591
4 to 14 0.157 to 0.551
6.5 to 10 0.256 to 0.394
7 to 12
0.276 to 0.472
3 to 14
0.118 to 0.551
35 1.378
32 1.260
2 to 15 0.079 to 0.591
5 to 9 0.197 to 0.354
5 to 15
0.197 to 0.591
1 to 30
0.039 to 1.181
12.5 0.492
12 0.472
0.5 to 7 0.020 to 0.276
0.5 to 4 0.020 to 0.157
1 to 4.5
–40 to
0.039 to 0.177
0.5 to 7 IP30 +60 °C
0.020 to 0.276
4m
R2
R4
HYPR
3m
2m
Bending
durability
R4
W7.2 × H7.5 × D2
R2
2m
R1
R2
FD-L12W
R1
0 to 110 0 to 4.331
0 to 43 0 to 1.693
STD
0 to 29 0 to 1.142
HYPR
0 to 30 0 to 1.181
STD
0 to 9.5 0 to 0.374
HYPR
0 to 11.5 0 to 0.453
STD
0 to 5 0 to 0.197
HYPR
0 to 6 0 to 0.236
Bending
durability
Bending
durability
0 to 56 0 to 2.205
STD
3m
Bending
durability
HYPR
STD
Bending
durability
FD-L20H
W6 × H18 × D14
FX-101
Ambient
(Upper value) Protection temp. Dimensions
FX-102
(Lower value)
0 to 43 0 to 1.693
0 to 43 0 to 1.693
0 to 42 0 to 1.654
0 to 29 0 to 1.142
Bending
durability
W12 × H19 × D3
Retroreflective
Type
U-LG
LONG
FAST
H-SP
16 to 30
0.630 to 1.181
0 to 50
0 to 1.969
7RXJK
FD-L11
FX-500 series
0 to 87 0 to 3.425
0 to 74 0 to 2.913
1 to 38 0.039 to 1.496
Cannot use
W18 × H29 × D3.8
Seating confirmation
Sensing range (mm in) (Note 1, 2)
STD
R4
7RXJK
Seating confirmation
Thru-beam
Type
Fiber
Bending cable
radius length
:
(mm)
Free-cut
1m
–40 to
P.63
+60 °C
0 to
+70 °C
–20 to
+70 °C
IP40
P.62
–40 to
+60 °C
–40 to
+70 °C
Notes: 1) The sensing range is specified for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm
t0.079 in) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 × 100 mm 3.937 × 3.937 in).
2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
27
Retroreflective Type
New product
introduction
Tough
Fiber
Compared with the thru-beam type, it is easier to
arrange the fibers since one side is a reflector. Sensing
transparent objects is also its advantage.
Fiber
Selection
Guide
Model
Choose
by shape/
application
Applications
Detecting transparent film
Detecting wafers
Detecting transparent seals on
transparent sheet
How to read
Model No.
Earlier models
comparison
table
FR-KZ50E
FR-Z50HW
Fibers
Super
Quality
FR-KZ22E
Threaded
Type
Reflector
RF-003
(Accessory for
FR-KZ50E)
Square Head
Type
Cylindrical
Type
Sleeve
LIST OF FIBERS
Flat
Type
Retroreflective type
Side sensing Top sensing
Narrow beam
With
filters
Wafer mapping polarizing
Type
Shape of fiber head
(mm)
Model No.
Fiber
Bending cable
radius length
:
(mm)
Free-cut
W5.2 × H9.5 × D16
R1
FR-Z50HW
W30 × H30 × D0.5
Small
Spot
Sensing range (mm in) (Note 1, 2)
U-LG
LONG
FX-500 series
FAST
H-SP
STD
100 to 1,400 3.937 to 55.118
100 to 990 3.937 to 38.976 100 to 1,200 3.937 to 47.244
100 to 780 3.937 to 30.709
HYPR
100 to 1,900 3.937 to 74.803 100 to 490 3.937 to 19.291
FX-101
(Upper value)
FX-102
(Lower value)
Protection
Ambient
Dimensions
temp.
STD
15 to 310 0.591 to 12.205
HYPR
15 to 570 0.591 to 22.441
FR-KZ22E
W4 × H2 × D21.5
W5.2 × H9.5 × D21
100 to 550
3.937 to 21.654 IP40 –25 to
100 to 830
+55 °C
3.937 to 32.677
FR-KZ50H
W10.6 × H28 × D10.1
W9.5 × H25 × D5.2
Bending
durability
Retroreflective
Type
Chemical / Oilresistant
FR-KZ50E
Heatresistant
P.55
IP30
STD
20 to 300 0.787 to 11.811
HYPR
20 to 1,000 0.787 to 39.370
7RXJK
15 to 200
0.591 to 7.874
15 to 360
0.591 to 14.173
2m
R2
7RXJK
15 to 460 0.591 to 18.110
15 to 410 0.591 to 16.142
15 to 220 0.591 to 8.661
15 to 100 0.591 to 3.937
20 to 800 0.787 to 31.496
20 to 400 0.787 to 15.748
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
–40 to
+60 °C
20 to 200
0.787 to 7.874
20 to 350
0.787 to 13.780
RF-220
RF-210
Liquid Leak /
Liquid Detection
W28 × H10.6 × D10.1
Sensing range when FR-Z50HW is used in combination with a reflector (optional)
RF-230
Vacuumresistant
Fiber
Options
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.
Reflector
model No.
Wide
Beam
Convergent
Reflective
Type
W7.5 × H2.2 × D11.2
7RXJK
Narrow
Beam
HYPR
U-LG
100 to 19,000
3.937 to 748.030
100 to 8,000
3.937 to 314.960
100 to 5,500
3.937 to 216.535
100 to 8,000
3.937 to 314.960
100 to 4,700
3.937 to 185.039
100 to 2,700
3.937 to 106.299
Sensing range (mm in)
FX-500 series
LONG
STD
FAST
100 to 5,000
3.937 to 196.850
100 to 3,500
3.937 to 137.795
100 to 2,400
3.937 to 94.488
100 to 3,600
3.937 to 141.732
100 to 3,000
3.937 to 118.110
100 to 1,500
3.937 to 59.055
100 to 2,900
3.937 to 114.173
100 to 1,800
3.937 to 70.866
100 to 1,200
3.937 to 47.244
H-SP
100 to 1,400
3.937 to 55.118
100 to 830
3.937 to 32.677
100 to 530
3.937 to 20.866
FX-101
100 to 2,400
3.937 to 94.488
100 to 1,300
3.937 to 51.181
100 to 980
3.937 to 38.583
FX-102
100 to 5,000
3.937 to 196.850
100 to 2,600
3.937 to 102.362
100 to 1,300
3.937 to 51.181
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Note: The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than 100 mm 3.937 in.
However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs,
adjust the threshold value of the amplifier unit before use.
Amplifiers
FIBER OPTION
▲
Reflectors (for FR-Z50HW) P.45
FX-500
series
FX-100
series
INDEX
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
28
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Chemical / Oil-resistant
With the case and fiber sheath made of PFA, the fiber can be used
with various types of chemical liquids.
The fiber core will not harden or break, even in environments where
oil is present.
Full-protection type
FT-R60Y (Square head type M6 / thru-beam type)
High environmental
resistance
The head, nut, and washer
are made from rust-resistant
SUS304. The unbreakable
tough fiber with high durability is
covered in a fluorine resin tube.
The fiber head is also covered
with a fluorine resin component,
achieving a high level of
environmental resistance.
Less susceptibility to oil
adhesion thanks to fluorine
resin
Fibers deliver stable detection,
since the sensing part is sealed
with fluorine resin, which
does not allow oil penetration.
Additionally, the detection part
features a convex design made
of fluorine resin, achieving lower
friction than glass.
Sleeve
Flat
Type
M6
Test oil
Lubricating oil
Small
Spot
Non-water-soluble cutting oil
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Resistant to oil and coolant
The fiber head and fiber cable are connected by
the “fastening and caulking” method without using
adhesives. This method eliminates concerns that
adhesives will absorb moisture in high-humidity
environments and
damage the fiber. The
enclosure achieves
IP68G protection,
so the fiber can be
installed around metal
processing machines
shrouded in the oil mist.
Stainless
steel
(SUS304)
Fluorine resin
(PFA)
Water-soluble cutting oil
Less susceptible to oil
adhesion than glass
Retroreflective
Type
Alcohol-based neutral detergent
Product
Velocite Oil No. 3
Yushiron Cut Abas KZ201
Yushiron Cut UH75
Syntilo 9954 (10% diluted)
Yushiroken S50N (2% diluted)
Super Teepol
*Yushiron and Yushiroken are registered trademarks of Yushiro
Chemical Industry Co., Ltd.
Chemical / Oilresistant
Heatresistant
Cable-protection type
Vacuumresistant
FT-R44Y (Square head type M4 / thru-beam type)
Liquid Leak /
Liquid Detection
Compatible with
optional lens
Stainless
steel
(SUS304)
Fiber
Options
M4
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
FT-R44Y / FD-R61Y
Fluorine resin
(PFA)
Full-protection type
Metal-free design
Since no metal components are used,
there is no need to worry about metal
contamination, even if the protective
tube is damaged. It is ideal for use in
applications such as semiconductor
front-end equipment where a clean
environment is required.
FD-R61Y (Square head type M6 / reflective type)
Stainless
steel
(SUS304)
M6
Fluorine resin
(PFA)
FD-S60Y (Cylindrical type / reflective type) Metal-free
Detection in long range and narrow
view
A built-in lens achieves narrow-view
detection with an aperture angle of 30
degrees.
Improved tip flexibility
The protective tube features a bending radius
of R30 mm R1.181 in, which improved the
cable arrangement compared to previous
(R40 mm R1.575 in) designs.
R30 mm
R1.181 in
Metal-free design
ø4 mm ø0.157 in
ø5.5 mm ø0.217 in
29
LIST OF FIBERS
New product
introduction
Thru-beam type (one pair set)
Shape of fiber head
(mm)
Model No.
FT-R44Y
W7×H9.5×D15.5
Full-protection type
7RXJK
FT-R60Y
R4
Bending
durability
2m
W10×H11×D21.2
Easy mounting • Rectangular head
SEMI S2 compliant
W7 × H15 × D13
Metal-free
Sensing range (mm in) (Note 1)
FX-500 series
STD
7RXJK
Cable-protection type
Compatible with lens
720 28.346
HYPR
3,000 118.110
STD
2,100 82.677
HYPR
(Note 2) 3,600 141.732
FT-Z802Y
STD
R4
Bending
durability
2m
HYPR
(Note 2)
STD
ø5.5
FT-HL80Y
(Note 2)
HYPR
(Note 2)
(25)
Metal-free
STD
ø5.5
FT-L80Y
R30
(25)
(Note 2)
2m
HYPR
(Note 3)
(Note 2)
Side-view
STD
Metal-free
ø5.5
(25)
U-LG
LONG
FAST
H-SP
1,600 62.992
1,100 43.307
430 16.929
130 5.118
3,600 141.732(Note 2)
3,600 141.732(Note 2)
1,260 49.606
400 15.748
Beam
FX-101
axis
Ambient
(Upper value) dia. Protection temp. Dimensions
FX-102
(mm)
(Lower value)
210 8.268
640 25.197
ø1
IP67
(Note 4)
P.52
FT-V80Y
HYPR
3,600 141.732(Note 2)
3,100 122.047 3,600 141.732(Note 2)
520 20.472
1,900 74.803 3,100 122.047
470 18.504
3,600 141.732
3,600 141.732(Note 2)
3,600 141.732 3,600 141.732(Note 2)
2,300 90.551
740 29.134
3,600 141.732
3,600 141.732
Choose
by shape/
application
Earlier models
comparison
table
P.54
Fibers
Super
Quality
990 38.976 ø3.7 IP68G –40 to P.50
2,340 92.126
+115 °C
3,600 141.732(Note 2)
3,600 141.732 3,600 141.732(Note 2) 1,100 43.307
2,800 110.236 2,600 102.362
920 36.220
3,600 141.732
1,300 51.181
(Note 2)
0 to
+60 °C
Fiber
Selection
Guide
How to read
Model No.
–55 to
+80 °C
690 27.165
1,890 74.409 ø3.5
Tough
Fiber
Model
–55 to
+80 °C
7RXJK
Heat-resistant 115 °C
Metal-free
Cylindrical type
Chemical-resistant
Flat type
Oil-resistant
Square head type
M6
M4
Type
Fiber
Bending cable
radius length
:
(mm)
Free-cut
2,800 110.236
2,200 86.614
800 31.496
240 9.449
P.51
–40 to
+70 °C
340 13.386
800 31.496 ø2.8
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
P.53
Small
Spot
Narrow
Beam
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
3) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted.
4) The fiber part is oil-resistant.
Convergent
Reflective
Type
Reflective type
Retroreflective
Type
Chemical-resistant Oil-resistant
Square head type
Cylindrical type
M6
Type
Shape of fiber head
(mm)
Cable-protection type
W10×H11×D15.5
Metal-free
Model No.
7RXJK
FD-R61Y
16
R4
Bending
durability
Protective tube
R30 mm Fiber
7RXJK
ø5.5
Fiber
Bending cable
radius length
:
(mm)
Free-cut
FD-S60Y
2m
Sensing range (mm in) (Note 1, 2)
FX-101
U-LG
(Upper value)
LONG
FX-500 series
FX-102
FAST
(Lower value)
H-SP
STD
280 11.024
HYPR
990 38.976
STD
320 12.598
2m
Bending (Note 4) HYPR
600 23.622
durability
R4
Wide
Beam
Beam
axis
Ambient
Protection
Dimensions
dia.
temp.
(mm)
610 24.016
435 17.126
160 6.299
50 1.969
85 3.346
185 7.283
—
(Note 3)
590 23.228
420 16.535
200 7.874
75 2.953
140 5.512
300 11.811
—
IP68G
IP67
Applications
–40 to
+70 °C
Fiber
Options
P.64
Semi-custom
fibers
Sensing a wafer in corrosive environment
FT-HL80Y
FT-L80Y
FT-Z802Y
Vacuumresistant
Liquid Leak /
Liquid Detection
Cleaning tank
Wafer
cassette
Heatresistant
–55 to
P.63
+80 °C
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.
2) The sensing range is specified for white, non-glossy paper.
3) The fiber part is oil-resistant.
4) The allowable cutting range is 500 mm 19.685 in from the end that is inserted to the amplifier.
Detecting wafer cassette in cleaning tank
Chemical / Oilresistant
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Wafer
Detecting a container at a chemical Piller
Amplifiers
FX-500
series
FT-Z802Y
FX-100
series
INDEX
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
30
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Heat-resistant
It can be used under environments of -60 to +350 °C
-76 to +662 °F.
A joint type for wider workability is also available.
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Applications
IC detection within a high
temperature handler
Detecting glass substrates
FT-H20W-M1
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
LIST OF FIBERS
Thru-beam type (one pair set)
HeatShape of fiber head
Type resistant
(mm)
temp.
Lens mountable
(FX-LE1/LE2/SV1)
Chemical / Oilresistant
Heatresistant
M4
ø2.1
Heat-resistant
Fiber
Options
27
Allows flexible wiring
Lens mountable
(FX-LE1/LE2/SV1)
200 °C
Semi-custom
fibers
130 °C
FT-H35-M2
30
350 °C Sleeve
Sleeve 60
60 mm
mm
Vacuumresistant
Liquid Leak /
Liquid Detection
M4
Model No.
M4
FT-H35-M2S6
Bending Fiber cable
radius length
(mm)
: Free-cut
R25
Fiber
R25
Sleeve
FT-H20W-M1
R10
1m
M4
23
Lens mountable (FX-LE2 only)
M4
FT-H20-M1
R25
FT-H13-FM2
2m
16
Lens mountable
(FX-LE1/LE2/SV1)
Fiber
Dimensions
FT-H20-J20-S
(Note 5)
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Heat-resistant (joint)
Thru-beam
Type
M4
23
FT-H20-J30-S
(Note 5)
FT-H20-J50-S
(Note 5)
200 °C
Side-view
ø3.8
24
ø4
STD
430 16.929
HYPR
1,200 47.244
880 34.646
670 26.378
170 6.693
250 9.843 490 19.291
80 3.150
ø1.2
–60 to
+350 °C
R10
23
Lens mountable
(FX-LE1/LE2/SV1)
2m
Sensing range (mm in) (Note 1)
Beam
FX-101 axis
Ambient
U-LG
Dimensions
(Upper value) dia.
temp.
LONG
FX-500 series
FX-102
FAST
(mm)
(Lower value)
H-SP
FT-H20-VJ50-S
(Note 5)
FT-H20-VJ80-S
(Note 5)
STD
1,000 39.370
470 18.504
840 33.071
300 11.811
HYPR
(Note 2) 1,600 62.992
90 3.543
P.50
100 3.937
300 11.811
STD
1,300 51.181
540 21.260
960 37.795
210 8.268
330 12.992 540 21.260
HYPR
(Note 2) 1,600 62.992
110 4.331
STD
1,900 74.803
700 27.559
1,300 51.181
250 9.843
410 16.142 700 27.559
HYPR
140 5.512
3,300 129.921
ø0.8
–60 to
+200 °C
ø1.2
ø1.5
–60 to
P.49
+130 °C
ø1.2
–60 to
P.50
+200 °C
200 mm
(Note 3)
Heatresistant
side
R18
(Note 4)
300 mm
(Note 3)
STD
1,000 39.370
470 18.504
790 31.102
135 5.315
300 11.811 420 16.535
HYPR
90 3.543
1,600 62.992
500 mm
(Note 3)
STD
800 mm
(Note 3)
600 23.622
HYPR
2,100 82.677
1,300 51.181
980 38.583
150 5.906
390 15.354 500 19.685
120 4.724
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
3) Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut).
4) Bending durable fiber R4 mm R0.157 in or more for ordinary temperature side.
5) Heat-resistant joint fibers and ordinary-temperature fibers (FT-42) are sold as a set.
31
Heat-resistant joint fiber set contents
New product
introduction
Heat-resistant side (–60 to +200 °C –76 to +392 °F)
Ordinary temperature
(–40 to +70 °C –40 to +158 °F)
Tough
Fiber
Ordinary temperature side
100 mm 3.937 in
approx.
Amplifiers
Fiber
Selection
Guide
Model
Heat-resistant
side fiber
Choose
by shape/
application
Ordinary temperature side fiber [FT-42
(Fiber cable length 2m, Free-cut)]
Nut (resin)
How to read
Model No.
Nut (metal), Use when securing to a mounting bracket.
Earlier models
comparison
table
Model No. when ordering individually as spare parts
• Heat-resistant side fiber one pair set
FT-H20-J20, FT-H20-J30, FT-H20-J50, FT-H20-VJ50, FT-H20-VJ80
Fibers
Super
Quality
• Ordinary temperature side fiber one pair set
FT-42
Threaded
Type
Square Head
Type
LIST OF FIBERS
Cylindrical
Type
Reflective type
HeatShape of fiber head
Type resistant
(mm)
temp.
Model No.
Bending Fiber cable
radius length
(mm)
: Free-cut
Sensing range (mm in) (Note 1, 2)
FX-101 Ambient
U-LG
Dimensions
(Upper value) temp.
LONG
FX-500 series
FX-102
FAST
H-SP
(Lower value)
Coaxial
M6
FD-H35-M2
25
2m
ø2.8
M6
350 °C
FD-H35-M2S6
22
Sleeve 90 mm
Threaded
M4
27
FD-H35-20S
Fiber
R25
Sleeve
R10
Coaxial
M6
200 °C
Heat-resistant
ø2.1
1m
FD-H20-M1
28
Coaxial
M4
FD-H20-21
27
130 °C
FD-H13-FM2
Glass substrate detection convergent reflective
21
FD-H30-L32
300 °C
R25
250 °C
540 21.260
460 18.110
150 5.906
45 1.772
STD
260 10.236
HYPR
840 33.071
550 21.654
440 17.323
140 5.512
45 1.772
85 3.346
200 7.874
STD
550 21.654
500 19.685
200 7.874
55 2.165
120 4.724
300 11.811
500 19.685
380 14.961
130 5.118
45 1.772
90 3.543
280 11.024
640 25.197
600 23.622
200 7.874
65 2.559
100 3.937 –60 to
280 11.024 +130 °C
330 12.992
HYPR
840 33.071
STD
230 9.055
HYPR
770 30.315
2m
350 13.780
HYPR
880 34.646
2m
STD
17 0.669
HYPR
40 1.575
W19 × H27 × D5
W21 × H33.2 × D5
W21 × H34.5 × D5
FD-H25-L43
3m
FD-H25-L45
FD-H18-L31
180 °C
W19 × H27 × D5
2m
STD
1.5 to 26 0.059 to 1.024
HYPR
1 to 31 0.039 to 1.220
STD
5 to 42 0.197 to 1.654
HYPR
4 to 43.5 0.157 to 1.713
STD
16 0.630
HYPR
60 2.362
75 2.953
280 11.024
–60 to
+350 °C
P.61
Retroreflective
Type
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
–60 to
+200 °C
30 1.181
2 to 9
25 0.984 0.079 to 0.354 –60 to
12 0.472
0 to 17 +300 °C
1.5 to 6 0.059 to 0.236
0 to 0.669
1 to 30 0.039 to 1.181
4 to 16
1 to 28 0.039 to 1.102 0.157 to 0.630 –20 to
1.5 to 24 0.059 to 0.945
4 to 23 +250 °C
2 to 18 0.079 to 0.709 0.157 to 0.906 Ordinary
4 to 43 0.157 to 1.693
7 to 35 temp. side:
4.5 to 43 0.177 to 1.693 0.276 to 1.378 –20 to
5 to 40 0.197 to 1.575
7 to 38 +70 °C
6.5 to 34 0.256 to 1.339 0.276 to 1.496
32 1.260
24 0.945
13 0.512
2 to 6.5 0.079 to 0.256
Convergent
Reflective
Type
Chemical / Oilresistant
0 to 10
0 to 0.394 –60 to
0 to 25 +180 °C
0 to 0.984
Notes: 1) The sensing range of reflective type is the value for white non-glossy paper (50 × 50 mm 1.969 × 1.969 in glass substrate for FD-H30-L32,
FD-H18-L31, transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in for FD-H25-L43 and FD-H25-L45).
2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
FIBER OPTION
Small
Spot
Wide
Beam
STD
260 10.236
HYPR
720 28.346
STD
M6
Flat
Type
Narrow
Beam
R25
Sleeve 60 mm
Sleeve
P.60
Fiber
Options
Semi-custom
fibers
P.61
Fiber
Dimensions
Thru-beam
Type
P.60
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
▲
Lens (For thru-beam type fiber) P.42
INDEX
32
New product
introduction
Tough
Fiber
Vacuum-resistant
Usable in high-temperatures of 300 °C 572 °F vacuum
The leakage of FV-BR1 is still less than a very slight
1.33 × 10–10 Pa · m3/s [He], so that it can be used in
vacuums with confidence.
Fiber
Selection
Guide
Model
Choose
by shape/
application
Applications
Highly resistant to repeated bending
Detecting an FPD in vacuum chamber
Vacuum resistant
long range reflective fiber
Vacuum resistant convergent
reflective fiber
Fibers
FD-H30-KZ1V-S
FD-H30-L32V-S
How to read
Model No
Earlier models
comparison
table
FT-H30-M1V-S
Because it has a bending durability of over 100,000
times (R20 mm R0.787 in), it is highly resistant to
repeated bending and is optimal for mounting on
moving robot hand.
FD-H30-KZ1V-S
FD-H30-L32V-S
Vacuum resistant
expansion lens
Super
Quality
FV-LE1
Threaded
Type
Vacuum resistant
thru-beam fiber
Square Head
Type
FT-H30-M1V-S
Cylindrical
Type
Sleeve
Flat
Type
Vacuum resistant
thru-beam fiber
Small
Spot
FT-H30-M1V-S
Narrow
Beam
Vacuum resistant side-view lens
FV-SV2
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Thru-beam type (one pair set)
Type
Thru-beam
Vacuumresistant
LIST OF FIBERS
Vacuumresistant
Heatresistant
Shape of fiber head
(mm)
300 °C
Lens mountable (FV-LE1/SV2) M4
30
Model No.
FT-H30-M1V-S
(Note)
Bending Fiber
radius cable
length
(mm)
R18
1m
Sensing range (mm in)
FX-500 series
STD
270 10.630
HYPR
1,000 39.370
FX-101
(Upper value)
FX-102
(Lower value)
U-LG
LONG
FAST
H-SP
590 23.228
470 18.504
160 6.299
55 2.165
110 4.331
280 11.024
Beam
axis dia.
(mm)
Ambient
temp.
Dimensions
ø1.2
–30 to
+300 °C
P.50
Note: Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
Reflective type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Type
Convergent
Reflective
reflective
Thru-beam
Type
Vacuum-resistant
Fiber
Dimensions
Shape of fiber head
(mm)
Model No.
Bending Fiber
radius cable
length
(mm)
300 °C, Rectangular head
W9.5 × H5.2 × D15
W19 × H5 × D27
U-LG
LONG
FAST
H-SP
FX-101
Ambient
Dimensions
(Upper value) temp.
FX-102
(Lower value)
1m
10 to 340 0.394 to 13.386
25 to 80
20 to 200 0.787 to 7.874 15 to 270 0.591 to 10.630 0.984 to 3.150
20
to
120
0.787
to
4.724
10
to 220
HYPR
20 to 45 0.787 to 1.772 0.394 to 8.661
5 to 500 0.197 to 19.685
3m
STD
8 0.315
HYPR
18 0.709
R18
FD-H30-L32V-S
(Note 1)
FX-500 series
STD
FD-H30-KZ1V-S
(Note 1)
300 °C, Glass substrate detection
Sensing range (mm in)(Note 2)
–30 to
12 0.472
2.5 to 6.5 +300 °C
10 0.394 0.098 to 0.256
5.5 0.217
0 to 11
1.5 to 3 0.059 to 0.118
0 to 0.433
Notes: 1) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
2) The sensing range of reflective type is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in.
P.61
33
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Vacuum-resistant fiber set contents
Vacuum side
Atmospheric side
Earlier models
comparison
table
Digital fiber sensor
Fibers
Vacuum
resistant fibers
Super
Quality
Atmospheric side fiber (FT-J8)
Chamber wall or flange
Threaded
Type
Photo-terminals (FV-BR1)
Square Head
Type
(Recommended thickness: 3.0 to 20 mm 0.118 to 0.787 in)
Cylindrical
Type
Model No. when ordering individually as spare parts
●
Vacuum resistant fiber
FT-H30-M1V (one pair set)
FD-H30-KZ1V
FD-H30-L32V
●
●
Photo-terminal
FV-BR1 (one pair set)
Atmospheric side fiber
FT-J8 (one pair set)
Sleeve
●
ounting bracket for FD-H30-KZ1V(-S)
M
MS-FD-2
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
FIBER OPTIONS
Retroreflective
Type
Lens (For thru-beam fiber)
For thru-beam type fiber
Designation
Vacuum
resistant
expansion lens
(Note 1)
Model No.
Chemical / Oilresistant
Description
Heatresistant
Fiber
Mode
Liquid Leak /
Liquid Detection
FX-500 series
Amplifier
FV-LE1
HYPR
U-LG
LONG
STD
3,600
3,600
3,400
1,500
FT-H30-M1V-S 141.732 141.732 133.858 59.055
(Note 2)
Vacuum
resistant
side-view lens
(Note 1)
Vacuumresistant
Increases the sensing range 4 times or more.
• Ambient temperature: –60 to +350 °C –76 to +662 °F (Note 3)
• Beam axis dia: ø3.6 mm ø0.142 in
Sensing range (mm in) [Lens on both sides] (Note 4)
(Note 2)
FX-100 series
FAST
H-SP
FX-101
FX-102
900
35.433
370
14.567
450
17.717
1,600
62.992
Beam axis is bent by 90°.
• Ambient temperature: –60 to +300 °C –76 to +572 °F (Note 3)
• Beam axis dia: ø3.7 mm ø0.146 in
Sensing range (mm in) [Lens on both sides] (Note 4)
Fiber
Mode
Semi-custom
fibers
FX-500 series
Amplifier
FV-SV2
HYPR
U-LG
LONG
STD
3,600
3,600
3,400
1,500
FT-H30-M1V-S 141.732 141.732 133.858 59.055
(Note 2)
(Note 2)
Fiber
Options
FX-100 series
FAST
H-SP
FX-101
FX-102
900
35.433
370
14.567
450
17.717
1,600
62.992
Notes: 1) Be careful when installing the thru-beam type fiber equipped with the lens, as the beam envelope becomes narrow and alignment is difficult.
2) The fiber cable length practically limits the sensing range.
3) Refer to previous page for the ambient temperature of fibers to be used in combination.
4) The fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series, in FX-102 take into
account the length of the FT-J8 atmospheric side fiber.
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
34
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Liquid Leak / Liquid Detection
It corresponds to various liquid events, from the contact (wetted) type to the pipe
mounting type, and up to leak detection.
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
For detecting the upper limit of liquid
surface level, sensor that receives beam
when “liquid is absent” is recommended.
For detecting the lower limit of liquid
surface level, sensor that receives beam
when “liquid is present” is recommended.
The sensor will turn OFF during abnormal conditions
(excess fluid, fiber disconnection, etc.)!
Liquid absent: Beam received (Output ON)
Liquid present / fiber is cutoff: Beam not received (Output OFF)
The sensor will turn OFF during abnormal conditions (insufficient liquid, fiber disconnection, etc.) !
Liquid present: Beam received (Output ON)
Liquid absent / fiber is cutoff: Beam not receired (Output OFF)
FD-FA93
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
FD-F41
FD-F41
FD-F4
Standard type
FT-F93
FD-F4
For 1 mm 0.039 in thick pipes
manufactured by PFA
Full-protection type
FD-HF40Y / FD-F41Y (Liquid level sensing) Metal-free
FD-HF40Y
Small
diameter
type
R10 mm R0.394 in
R10 mm R0.394 in
Primary sheath: Polyethylene
Secondary sheath: Fluorine resin
2,000 mm
78.740 in
2,000 mm
78.740 in
(ø4 mm ø0.157 in)
Bends easily with
its small bending
radius, protective
tube is cuttable
and extendable
FD-F41Y
Sheath: Polyethylene
R20 mm R0.787 in
R20 mm R0.787 in
ø4 mm ø0.157 in protective
tube (fluorine resin)
ø4 mm ø0.157 in protective
tube (fluorine resin)
500 mm
19.685 in
(Cuttable*)
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
(When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in)
Chemical / Oilresistant
Heatresistant
FT-F93
Strong against air bubbles
Applicable pipe: Transparent pipe, Outer diameter ø8 mm
ø0.315 in or more
500 mm
19.685 in
(Cuttable*)
Heat-resistant
+105 °C +221 °F
Heat-resistant
+70 °C +158 °F
Thru-beam
Type
Retroreflective
Type
* The range of 50 mm 1.969 in from the fiber tip cannot be cut. Also, fiber length can be extended using MS-FX-02Y (optional).
Reflective
Type
Others
Full-protection type
FD-F71 (Liquid level sensing) SEMI S2 compliant
Detect chemical leaks in semiconductor and LCD manufacturing processes.
Amplifiers
Compact, space-saving
FX-500
series
Side-mountable fiber head as slim as 10 mm 0.394 in is good to use in
confined spaces.
FX-100
series
INDEX
Ideal for use with chemicals and volatile materials
This fiber type sensor is safer to use with volatile materials (SEMI S2
compliant). The fluorine resin fiber head makes it ideal for use with
chemicals.
35
LIST OF FIBERS
New product
introduction
Reflective type / Thru-beam type
Liquid level sensing
leak
Liquid level sensing Liquid
detection
Contact type
Type
Shape of fiber head
(mm)
Heat resistant 125 °C
Fluorine resin coating
ø6
Heat resistant 105 °C
Fluorine resin coating
Metal-free
ø4
Heat resistant 70 °C
Fluorine resin coating throughout the fiber
Metal-free
ø4
SEMI S2 compliant
W20 × H30 × D10
Bending
radius
(mm)
Model No.
Protective tube
R40
Fiber
R15
FD-F8Y
ø4 mm ø0.157 in
Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received,
Liquid surface contacted: Beam not received
–40 to
P.61
+105 °C
R20
Fiber
2m
R10
(Note 2)
7RXJK
R4
FD-F71
FX-101
FX-102
–40 to
IP68
P.59
+125 °C
Protective tube
FD-F41Y
FX-500 series
(STD mode)
Ambient
Protection
Dimensions
temp.
ø6 mm ø0.236 in
Protective tube: Fluorine resin, length 1,000 mm 39.370 in (not cuttable)
2m
Liquid surface not contacted: Beam received,
(Note 1) Liquid surface contacted: Beam not received
FD-HF40Y
(Note 2)
Description
Fiber cable
length
: Free-cut
5m
Bending durability
ø4 mm ø0.157 in
Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received,
Liquid surface contacted: Beam not received
IP68G
–40 to
+70 °C
Liquid leak detection
–20 to
Leak absent: Beam received, Leak present: Beam interrupted IP67
+60 °C
Compatible amplifire: FX500 series only
Liquid sensing
Pipe-mountable type
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in
P.59
transparent pipe [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic,
W25 × H13 × D20
FD-F41
glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
Liquid absent: Beam received, Liquid present: Beam not received
–40 to
―
R10
For 1 mm thick PFA pipe
+100 °C
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to
ø1.024 in transparent pipe [PFA (fluorine resin) or equivalently
FD-F4
W25 × H13 × D20
transparent pipe, wall thickness 1 mm 0.039 in]
Liquid absent: Beam received, Liquid present: Beam not received
Mountable on pipe·array fiber 7RXJK
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more
2m
–40 to
transparent pipe (When used with the tying bands: ø8 to ø80 mm
R4
W6.5 × H28.3 × D17 FD-FA93
ø0.315 to ø3.150 in) [PFA (fluorine resin), including translucent]
+70 °C
Bending durability
Liquid absent: Beam received, Liquid present: Beam not received
SEMI S2 compliant
Applicable pipe diameter: Outer dia. ø3 to ø10 mm ø0.118 to IP40
Protective tube R20
7RXJK
ø0.394 in transparent pipe [PFA (fluorine resin) or equivalently
Fiber
–40 to
transparent pipe, wall thickness 0.3 to 1 mm 0.012 to 0.039 in]
P.49
FT-F93
+60 °C
R2
Liquid absent: Beam not received, Liquid present: Beam received
W23 × H20 × D17
Bending durability
Compatible amplifire: FX500 series only
Notes: 1) The allowable cutting range is 1,000 mm 39.370 in from the end that the amplifier inserted.
2) Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint is available.
Standard
Accessories for additional supply
●
MS-FD-F7-1
(SUS mounting bracket for FD-F71)
●
MS-FD-F7-2
(PVC mounting bracket for FD-F71)
FIBER OPTIONS
Model No.
MS-FX-01Y
Protective tube
extension joint
(Note)
Fiber mounting
joint
(Note)
MS-FX-02Y
MS-FX-03Y
MS-FX-01Y
• MS-FX-01Y
MS-FX-01Y
This joint suppresses false operations due to
liquid slip-in from the top of the protective tube.
FD-HF40Y
FD-F41Y
The protective tube can be extended.
Ferrule
(MS-FX-YF)
Body
Applications
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
MS-FX-02Y
• MS-FX-02Y
MS-FX-02Y
Union nut
Semi-custom
fibers
Fiber
mounting
MS-FX-03Y
MS-FX-03Y
• MS-FX-03Y
MS-FX-03Y
joint
Union nut
Union nut
Ferrule (MS-FX-YF)
Union nut
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Detecting liquid level in a tank
Fiber
Options
The joint is used for mounting fibers on a tank.
Protective
tube extension joint
MS-FX-02Y
Body
Body
Ferrule
Union
nut(MS-FX-YF)
Ferrule (MS-FX-YF)
Union nut
Union nut
Model
Description
Note: The joint internal ferrule (MS-FX-YF) is available as a spare part. A distorted ferrule may result in leakage.
Liquid
inflow prevention joint
MS-FX-01Y
Fiber
Selection
Guide
Liquid Leak /
Liquid Detection
Applicable fibers
Designation
Liquid inflow
prevention joint
(Note)
Tough
Fiber
Body
Ferrule
(MS-FX-YF)
Body
Body
Ferrule
Union
nut(MS-FX-YF)
Ferrule (MS-FX-YF)
Union nut
Union nut
Union
nut
Ferrule
(MS-FX-YF)
Union nut
Ferrule (MS-FX-YF)
Body
Ferrule (MS-FX-YF)
Body
Body
Leak detection for use in semiconductor
device manufacturing
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
FD-F71
INDEX
7RXJK : Refers
to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
36
New product
introduction
Tough
Fiber
Fibers are listed in alphabetic order.
Refer to p. 2~ for details of each fiber.
SENSING RANGE
Thru-beam type (one pair set)
Sensing range (mm in) (Note 1)
Fiber
Selection
Guide
HYPR
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
FX-500 series
Model No.
U-LG
LONG
STD
FX-100 series
FAST
H-SP
FX-101
FX-102
19,600
19,600
19,600
19,600
16,000
6,300
14,000
19,600
FT-140
771.652 (Note 2) 771.652 (Note 2) 771.652 (Note 2) 771.652 (Note 2)
629.920
248.031
551.180 771.652 (Note 2)
1,350
810
650
400
210
75
135
400
FT-30
53.150
31.890
25.591
15.748
8.268
2.953
5.315
15.748
1,350
770
550
315
210
70
130
340
FT-31
53.150
30.315
21.654
12.402
8.268
2.756
5.118
13.386
1,220
740
550
315
195
63
130
340
FT-31S
48.031
29.134
21.654
12.402
7.677
2.480
5.118
13.386
990
590
440
260
150
53
80
240
FT-31W
38.976
23.228
17.323
10.236
5.906
2.087
3.150
9.449
3,600
2,200
1,700
1,200
530
190
320
870
FT-40
141.732 (Note 2)
86.614
66.929
47.244
20.866
7.480
12.598
34.252
3,600
2,050
1,600
1,130
530
190
300
800
FT-42
141.732 (Note 2)
80.709
62.992
44.488
20.866
7.480
11.811
31.496
3,600
2,050
1,600
1,130
530
190
300
800
FT-42S
141.732 (Note 2)
80.709
62.992
44.488
20.866
7.480
11.811
31.496
3,300
1,900
1,400
800
490
160
260
720
FT-42W
129.921
74.803
55.118
31.496
19.291
6.299
10.236
28.346
3,600
2,800
2,100
1,400
770
240
350
970
FT-43
141.732 (Note 2)
110.236
82.677
55.118
30.315
9.449
13.780
38.189
1,600
1,600
1,600
1,200
630
200
340
920
FT-45X
62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2)
47.244
24.803
7.874
13.386
36.220
3,600
3,600
3,600
3,600
3,600
1,100
1,900
3,600
FT-A11
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
43.307
74.803 141.732 (Note 2)
3,600
3,600
3,600
3,600
3,600
1,300
1,700
3,400
FT-A11W
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
51.181
66.929
133.858
3,600
3,600
3,600
3,600
3,600
2,100
3,600
3,600
FT-A32
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
82.677 141.732 (Note 2) 141.732 (Note 2)
3,600
3,600
3,600
3,600
3,600
3,000
3,600
3,600
FT-A32W
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
118.110 141.732 (Note 2) 141.732 (Note 2)
2,300
1,550
1,500
860
500
170
250
660
FT-AL05
90.551
61.024
59.055
33.858
19.685
6.693
9.843
25.984
52
30
24
15
8
2
6
19
FT-E13
2.047
1.181
0.945
0.591
0.315
0.079
0.236
0.748
270
160
125
75
42
13
22
80
FT-E23
10.630
6.299
4.921
2.953
1.654
0.512
0.866
3.150
Applicable pipe diameter: Outer dia. ø3 to ø10 mm ø0.118 to ø0.394 in transparent pipe
[PFA (fluorine resin) or equivalently transparent pipe, wall thickness 0.3 to 1 mm 0.012 to 0.039 in]
FT-F93
Liquid absent: Beam interrupted, Liquid present: Beam received
Compatible amplifier: FX-500 series only
3,300
1,900
1,300
700
410
140
250
700
FT-H13-FM2
129.921
74.803
51.181
27.559
16.142
5.512
9.843
27.559
1,600
1,000
790
470
300
90
135
420
FT-H20-J20-S (Note 3)
62.992
39.370
31.102
18.504
11.811
3.543
5.315
16.535
1,600
1,000
790
470
300
90
135
420
FT-H20-J30-S (Note 3)
62.992
39.370
31.102
18.504
11.811
3.543
5.315
16.535
1,600
1,000
790
470
300
90
135
420
FT-H20-J50-S (Note 3)
62.992
39.370
31.102
18.504
11.811
3.543
5.315
16.535
1,600
1,300
960
540
330
110
210
540
FT-H20-M1
62.992 (Note 2)
51.181
37.795
21.260
12.992
4.331
8.268
21.260
2,100
1,300
980
600
390
120
150
500
FT-H20-VJ50-S (Note 3)
82.677
51.181
38.583
23.622
15.354
4.724
5.906
19.685
2,100
1,300
980
600
390
120
150
500
FT-H20-VJ80-S (Note 3)
82.677
51.181
38.583
23.622
15.354
4.724
5.906
19.685
1,600
1,000
840
470
300
90
100
300
FT-H20W-M1
62.992 (Note 2)
39.370
33.071
18.504
11.811
3.543
3.937
11.811
1,000
590
470
270
160
55
110
280
FT-H30-M1V-S (Note 4)
39.370
23.228
18.504
10.630
6.299
2.165
4.331
11.024
1,200
880
670
430
250
80
170
490
FT-H35-M2
47.244
34.646
26.378
16.929
9.843
3.150
6.693
19.291
1,200
880
670
430
250
80
170
490
FT-H35-M2S6
47.244
34.646
26.378
16.929
9.843
3.150
6.693
19.291
3,600
3,600
3,600
3,600
2,300
740
990
2,340
FT-HL80Y
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
90.551
29.134
38.976
92.126
3,600
3,600
3,600
3,600
3,600
1,200
2,200
3,600
FT-KS40
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
47.244
86.614 141.732 (Note 2)
2,500
1,600
1,200
710
440
160
135
560
FT-KV26
98.425
62.992
47.244
27.953
17.323
6.299
5.315
22.047
3,600
3,600
3,600
3,600
3,600
1,200
2,200
3,600
FT-KV40
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
47.244
86.614 141.732 (Note 2)
3,600
3,600
3,600
3,600
3,100
940
2,200
3,600
FT-KV40W
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
122.047
37.008
86.614 141.732 (Note 2)
3,600
3,600
3,600
3,600
2,800
920
1,100
2,600
FT-L80Y
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
110.236
36.220
43.307
102.362
1,000
580
440
270
160
55
100
340
FT-R31
39.370
22.835
17.323
10.630
6.299
2.165
3.937
13.386
3,600
1,750
1,500
930
500
160
270
740
FT-R40
141.732 (Note 2)
68.898
59.055
36.614
19.685
6.299
10.630
29.134
3,200
1,800
1,400
800
460
150
250
710
FT-R41W
125.984
70.866
55.118
31.496
18.110
5.906
9.843
27.953
3,600
3,600
3,500
2,200
1,300
460
510
2,000
FT-R42W
141.732 (Note 2) 141.732 (Note 2)
137.795
86.614
51.181
18.110
20.079
78.740
Notes: 1)
2)
3)
4)
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
The fiber cable length practically limits the sensing range.
Heat-resistant joint fibers and ordinary-temperature fibers (FT-42) are sold as a set.
Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
Dimensions
P.48
P.48
P.48
P.48
P.48
P.48
P.48
P.48
P.48
P.48
P.49
P.49
P.49
P.49
P.49
P.49
P.49
P.49
P.49
P.49
P.50
P.50
P.50
P.50
P.50
P.50
P.50
P.50
P.50
P.50
P.50
P.51
P.51
P.51
P.51
P.51
P.51
P.51
P.51
P.51
37
Fibers are listed in alphabetic order.
Refer to p. 2~ for details of each fiber.
SENSING RANGE
New product
introduction
Tough
Fiber
Thru-beam type (one pair set)
Sensing range (mm in) (Note 1)
FX-500 series
Model No.
FT-R43
FT-R44Y
FT-R60Y
FT-S11
FT-S20
FT-S21
FT-S21W
FT-S30
FT-S31W
FT-S32
FT-V23
FT-V24W
FT-V25
FT-V30
FT-V40
FT-V80Y
FT-Z20HBW
FT-Z20W
FT-Z30
FT-Z30E
FT-Z30EW
FT-Z30H
FT-Z30HW
FT-Z30W
FT-Z40HBW
FT-Z40W
FT-Z802Y
HYPR
U-LG
LONG
3,000
118.110
3,000
118.110
3,600
141.732 (Note 2)
350
13.780
1,350
53.150
1,350
53.150
990
38.976
3,600
141.732 (Note 2)
3,300
129.921
3,600
141.732 (Note 2)
1,800
70.866
380
14.961
900
35.433
2,200
86.614
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,100
43.307
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,300
129.921
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992
1,600
62.992
3,600
141.732 (Note 2)
210
8.268
810
31.890
770
30.315
590
23.228
2,200
86.614
1,900
74.803
3,600
141.732 (Note 2)
1,000
39.370
230
9.055
550
21.654
1,200
47.244
3,600
141.732 (Note 2)
2,800
110.236
670
26.378
1,500
59.055
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,300
129.921
1,900
74.803
3,300
129.921
3,600
141.732 (Note 2)
1,100
43.307
1,100
43.307
3,600
141.732 (Note 2)
160
6.299
650
25.591
550
21.654
440
17.323
1,700
66.929
1,400
55.118
3,600
141.732 (Note 2)
880
34.646
200
7.874
480
18.898
1,000
39.370
3,600
141.732 (Note 2)
2,200
86.614
570
22.441
1,100
43.307
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,200
125.984
1,400
55.118
2,300
90.551
3,600
141.732 (Note 2)
FX-100 series
STD
720
28.346
720
28.346
2,100
82.677
90
3.543
400
15.748
315
12.402
260
10.236
1,200
47.244
800
31.496
3,100
122.047
450
17.717
110
4.331
240
9.449
680
26.772
3,500
137.795
1,300
51.181
260
10.236
620
24.409
2,100
82.677
3,500
137.795
3,400
133.858
3,500
137.795
3,500
137.795
1,500
59.055
800
31.496
1,500
59.055
3,100
122.047
FAST
430
16.929
430
16.929
1,260
49.606
60
2.362
210
8.268
210
8.268
150
5.906
530
20.866
490
19.291
1,800
70.866
280
11.024
60
2.362
140
5.512
340
13.386
2,400
94.488
800
31.496
180
7.087
420
16.535
1,200
47.244
2,400
94.488
2,000
78.740
2,600
102.362
2,600
102.362
1,000
39.370
490
19.291
900
35.433
1,900
74.803
H-SP
130
5.118
130
5.118
400
15.748
19
0.748
75
2.953
70
2.756
53
2.087
190
7.480
160
6.299
600
23.622
90
3.543
20
0.787
45
1.772
100
3.937
850
33.465
240
9.449
55
2.165
130
5.118
410
16.142
740
29.134
630
24.803
810
31.890
810
31.890
280
11.024
160
6.299
290
11.417
470
18.504
FX-101
210
8.268
210
8.268
690
27.165
40
1.575
135
5.315
130
5.118
80
3.150
320
12.598
260
10.236
1,100
43.307
160
6.299
35
1.378
95
3.740
180
7.087
1,000
39.370
340
13.386
100
3.937
280
11.024
710
27.953
1,200
47.244
1,400
55.118
1,400
55.118
1,400
55.118
540
21.260
260
10.236
410
16.142
520
20.472
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
Dimensions
FX-102
640
25.197
640
25.197
1,890
74.409
90
3.543
400
15.748
340
13.386
240
9.449
870
34.252
720
28.346
3,000
118.110
400
15.748
90
3.543
260
10.236
480
18.898
3,100
122.047
800
31.496
320
12.598
730
28.740
2,300
90.551
3,200
125.984
2,600
102.362
3,200
125.984
3,200
125.984
1,800
70.866
720
28.346
1,200
47.244
3,100
122.047
Fiber
Selection
Guide
Model
P.51
P.52
P.52
P.52
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
P.52
P.52
P.52
P.52
P.52
Fibers
Super
Quality
Threaded
Type
P.52
Square Head
Type
P.52
Cylindrical
Type
P.53
Sleeve
P.53
Flat
Type
P.53
P.53
P.53
P.53
Small
Spot
Narrow
Beam
Wide
Beam
P.53
Convergent
Reflective
Type
P.53
Retroreflective
Type
P.53
Chemical / Oilresistant
P.54
P.54
P.54
P.54
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
P.54
P.54
P.54
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
38
New product
introduction
Tough
Fiber
Fibers are listed in alphabetic order.
Refer to p. 2~ for details of each fiber.
SENSING RANGE
Retroreflective type
Sensing range (mm in) (Note 1, 2)
Fiber
Selection
Guide
FX-500 series
Model No.
HYPR
U-LG
LONG
STD
FAST
H-SP
FX-101
FX-102
15 to 570
0.591 to 22.441
20 to 1,000
0.787 to 39.370
20 to 1,000
0.787 to 39.370
100 to 1,900
3.937 to 74.803
15 to 460
0.591 to 18.110
20 to 800
0.787 to 31.496
20 to 800
0.787 to 31.496
100 to 1,400
3.937 to 55.118
15 to 410
0.591 to 16.142
20 to 400
0.787 to 15.748
20 to 400
0.787 to 15.748
100 to 1,200
3.937 to 47.244
15 to 310
0.591 to 12.205
20 to 300
0.787 to 11.811
20 to 300
0.787 to 11.811
100 to 990
3.937 to 38.976
15 to 220
0.591 to 8.661
20 to 200
0.787 to 7.874
20 to 200
0.787 to 7.874
100 to 780
3.937 to 30.709
15 to 100
0.591 to 3.937
20 to 200
0.787 to 7.874
20 to 200
0.787 to 7.874
100 to 490
3.937 to 19.291
15 to 200
0.591 to 7.874
20 to 200
0.787 to 7.874
20 to 200
0.787 to 7.874
100 to 550
3.937 to 21.654
15 to 360
0.591 to 14.173
20 to 350
0.787 to 13.780
20 to 350
0.787 to 13.780
100 to 830
3.937 to 32.677
Model
Choose
by shape/
application
FR-KZ22E
How to read
Model No
FR-KZ50E
Earlier models
comparison
table
FR-KZ50H
FR-Z50HW
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Small
Spot
RF-230
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
P.55
P.55
P.55
P.55
Sensing range when FR-Z50HW is used in combination with a reflector (optional)
Reflector
Model No.
Wide
Beam
Dimensions
Notes: 1) Note
that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
The sensing range of FR-Z50HW is specified for the RF-13. The sensing range of FR-KZ50H and FR-KZ50E is specified for the
attached reflector RF-003. The sensing range of FR-KZ22E is specified for the attached reflector.
2) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range
for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber
head. If this occurs, adjust the threshold value of the amplifier unit before use.
Flat
Type
Narrow
Beam
FX-100 series
RF-220
RF-210
HYPR
U-LG
Sensing range (mm in)
FX-500 series
LONG
STD
FAST
H-SP
100 to 19,000
100 to 8,000
100 to 5,000
100 to 3,600
100 to 2,900
100 to 1,400
3.937 to 748.03 3.937 to 314.960 3.937 to 196.850 3.937 to 141.732 3.937 to 114.173 3.937 to 55.118
100 to 8,000
100 to 4,700
100 to 3,500
100 to 3,000
100 to 1,800
100 to 830
3.937 to 314.960 3.937 to 185.039 3.937 to 137.795 3.937 to 118.110 3.937 to 70.866 3.937 to 32.677
100 to 5,500
100 to 2,700
100 to 2,400
100 to 1,500
100 to 1,200
100 to 530
3.937 to 216.535 3.937 to 106.299 3.937 to 94.488 3.937 to 59.055 3.937 to 47.244 3.937 to 20.866
FX-100 series
FX-101
FX-102
100 to 2,400
100 to 5,000
3.937 to 94.488 3.937 to 196.850
100 to 1,300
100 to 2,600
3.937 to 51.181 3.937 to 102.362
100 to 980
100 to 1,300
3.937 to 38.583 3.937 to 51.181
Note: 1) The
sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than 100 mm 3.937
in. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use.
39
Fibers are listed in alphabetic order.
Refer to p. 2~ for details of each fiber.
SENSING RANGE
New product
introduction
Tough
Fiber
Reflective type
Sensing range (mm in) (Note 1, 2)
FX-500 series
Model No.
HYPR
FD-30
FD-31
FD-31W
FD-32G
FD-32GX
FD-40
FD-41
FD-41S
FD-41SW
FD-41W
FD-42G
FD-42GW
FD-60
FD-61
FD-61G
FD-61S
FD-61W
FD-62
FD-64X
600
23.622
515
20.276
330
12.992
650
25.591
630
24.803
600
23.622
515
20.276
515
20.276
330
12.992
900
35.433
650
25.591
670
26.378
1,550
61.024
1,400
55.118
1,100
43.307
1,200
47.244
900
35.433
1,500
59.055
670
26.378
FD-A16
FD-AL11
FD-E13
FD-E23
FD-EG30
FD-EG30S
FD-EG31
FD-F4
670
26.378
50
1.969
170
6.693
170
6.693
170
6.693
85
3.346
U-LG
LONG
STD
FX-100 series
FAST
H-SP
FX-101
330
250
160
80
25
45
12.992
9.843
6.299
3.150
0.984
1.772
290
220
125
80
25
35
11.417
8.661
4.921
3.150
0.984
1.378
180
140
80
45
12
15
7.087
5.512
3.150
1.772
0.472
0.591
380
270
200
95
27
70
14.961
10.630
7.874
3.740
1.063
2.756
410
360
200
100
30
75
16.142
14.173
7.874
3.937
1.181
2.953
330
250
160
80
25
45
12.992
9.843
6.299
3.150
0.984
1.772
290
220
125
80
25
35
11.417
8.661
4.921
3.150
0.984
1.378
290
220
125
80
25
35
11.417
8.661
4.921
3.150
0.984
1.378
180
140
80
45
12
15
7.087
5.512
3.150
1.772
0.472
0.591
630
430
270
150
45
80
24.803
16.929
10.630
5.906
1.772
3.150
380
270
200
95
27
70
14.961
10.630
7.874
3.740
1.063
2.756
340
280
150
90
25
45
13.386
11.024
5.906
3.543
0.984
1.772
900
740
520
260
90
140
35.433
29.134
20.472
10.236
3.543
5.512
840
670
450
200
70
120
33.071
26.378
17.717
7.874
2.756
4.724
800
650
420
200
60
120
31.496
25.591
16.535
7.874
2.362
4.724
790
660
420
220
75
130
31.102
25.984
16.535
8.661
2.953
5.118
630
430
270
150
45
80
24.803
16.929
10.630
5.906
1.772
3.150
1,000
940
520
340
110
170
39.370
37.008
20.472
13.386
4.331
6.693
500
410
280
160
50
75
19.685
16.142
11.024
6.299
1.969
2.953
200
200
200
140
75
120
7.874
7.874
7.874
5.512
2.953
4.724
530
510
320
180
50
100
20.866
20.079
12.598
7.087
1.969
3.937
29
25
12
7
2
5
1.142
0.984
0.472
0.276
0.079
0.197
120
80
55
30
9
20
4.724
3.150
2.165
1.181
0.354
0.787
130
110
48
30
9
20
5.118
4.331
1.890
1.181
0.354
0.787
110
80
50
30
9
20
4.331
3.150
1.969
1.181
0.354
0.787
45
35
20
12
3.5
7
1.772
1.378
0.787
0.472
0.138
0.276
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]
Liquid absent: Beam received, Liquid present: Beam interrupted
Dimensions
FX-102
155
6.102
140
5.512
60
2.362
190
7.480
210
8.268
155
6.102
140
5.512
140
5.512
60
2.362
230
9.055
190
7.480
140
5.512
420
16.535
410
16.142
350
13.780
360
14.173
230
9.055
450
17.717
220
8.661
240
9.449
285
11.220
15
0.591
70
2.756
70
2.756
70
2.756
25
0.984
Model
P.56
P.56
P.56
P.56
P.56
P.56
P.56
P.56
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
P.57
Cylindrical
Type
P.57
Sleeve
P.57
Flat
Type
P.57
P.57
P.57
P.57
Small
Spot
Narrow
Beam
Wide
Beam
P.57
Convergent
Reflective
Type
P.58
Retroreflective
Type
P.58
Chemical / Oilresistant
P.58
Heatresistant
P.58
P.58
P.58
Vacuumresistant
Liquid Leak /
Liquid Detection
P.59
P.59
Fiber
Options
P.59
ø4 mm ø0.157 in
Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
P.59
FD-F71
Liquid leak detection
Leak absent: Beam received, Leak present: Beam interrupted
Compatible amplifier: FX-500 series only
P.59
FD-F8Y
ø6 mm ø0.236 in
Protective tube: Fluorine resin, length 1,000 mm 39.370 in (not cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
P.59
FD-FA93
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe
(When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in)
[PFA (fluorine resin), including translucent]
Liquid absent: Beam received, Liquid present: Beam interrupted
P.59
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper.
3) Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint are available. Please refer to page 35 for details.
How to read
Model No.
P.56
P.59
FD-F41Y (Note 3)
Choose
by shape/
application
P.56
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
Liquid absent: Beam received, Liquid present: Beam interrupted
FD-F41
Fiber
Selection
Guide
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
40
New product
introduction
Tough
Fiber
Fibers are listed in alphabetic order.
Refer to p. 2~ for details of each fiber.
SENSING RANGE
Reflective type
Sensing range (mm in) (Note 1, 2)
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
HYPR
FD-HF40Y (Note 5)
FD-L10 (Note 3)
FD-L11 (Note 3)
FD-L12W (Note 3)
FD-L20H
Retroreflective
Type
FD-L21 (Note 3)
Chemical / Oilresistant
FD-L21W (Note 3)
Vacuumresistant
Liquid Leak /
Liquid Detection
FD-L22A (Note 3)
FD-L23 (Note 3)
FD-L30A (Note 3)
FD-L31A (Note 3)
FD-L32H (Note 3)
Fiber
Options
FD-R31G
FD-R32EG
FD-R33EG
Semi-custom
fibers
FD-R34EG
FD-R41
FD-R60
Fiber
Dimensions
FD-R61Y
Thru-beam
Type
FD-S21
Retroreflective
Type
FD-S30
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
U-LG
LONG
STD
FX-100 series
FAST
880
640
600
350
200
FD-H13-FM2
25.197
23.622
13.780
7.874
34.646
60
32
24
16
13
FD-H18-L31
2.362
1.260
0.945
0.630
0.512
770
500
380
230
130
FD-H20-21
30.315
19.685
14.961
9.055
5.118
840
550
500
330
200
FD-H20-M1
33.071
21.654
19.685
12.992
7.874
1 to 31
1 to 30
1 to 28
1.5 to 26
1.5 to 24
FD-H25-L43 (Note 3)
0.039 to 1.220 0.039 to 1.181 0.039 to 1.102 0.059 to 1.024 0.059 to 0.945
4
to
43.5
4
to
43
4.5
to
43
5
to
42
5 to 40
FD-H25-L45 (Note 3)
0.157 to 1.713 0.157 to 1.693 0.177 to 1.693 0.197 to 1.654 0.197 to 1.575
to 500
10 to 340
15 to 270
20 to 200
20 to120
FD-H30-KZ1V-S (Note 3, 4) 0.197 to519.685
0.394 to 13.386 0.591 to 10.630 0.787 to 7.874 0.787 to 4.724
40
30
25
17
12
FD-H30-L32
1.575
1.181
0.984
0.669
0.472
18
12
10
8
5.5
FD-H30-L32V-S (Note 3, 4)
0.709
0.472
0.394
0.315
0.217
840
550
440
260
140
FD-H35-20S
33.071
21.654
17.323
10.236
5.512
720
540
460
260
150
FD-H35-M2
28.346
21.260
18.110
10.236
5.906
720
540
460
260
150
FD-H35-M2S6
28.346
21.260
18.110
10.236
5.906
Convergent
Reflective
Type
Heatresistant
FX-500 series
Model No.
FD-S31
FD-S32
FX-101
H-SP
65
2.559
2 to 6.5
0.079 to 0.256
45
1.772
55
2.165
2 to 18
0.079 to 0.709
6.5 to 34
0.256 to 1.339
20 to 45
0.787 to 1.772
1.5 to 6
0.059 to 0.236
1.5 to 3
0.059 to 0.118
45
1.772
45
1.772
45
1.772
FX-102
100
280
3.937
11.024
0 to 10
0 to 25
0 to 0.394
0 to 0.984
90
280
3.543
11.024
120
300
4.724
11.811
4 to 16
4 to 23
0.157 to 0.630 0.157 to 0.906
7 to 35
7 to 38
0.276 to 1.378 0.276 to 1.496
25 to 80
10 to 220
0.984 to 3.150 0.394 to 8.661
2 to 9
0 to 17
0.079 to 0.354
0 to 0.669
2.5 to 6.5
0 to11
0.098 to 0.256
0 to 0.433
85
200
3.346
7.874
75
280
2.953
11.024
75
280
2.953
11.024
ø4 mm ø0.157 in
Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam not received
0 to 6
0 to 5.5
0 to 5.5
0 to 5
0 to 4.5
0 to 0.236
0 to 0.217
0 to 0.217
0 to 0.197
0 to 0.177
0 to 11.5
0 to 10.5
0 to 10
0 to 9.5
0 to 9
0 to 0.453
0 to 0.413
0 to 0.394
0 to 0.374
0 to 0.354
14
12.5
12
8
0.5 to 7
0.551
0.492
0.472
0.315 0.020 to 0.276
45
35
32
23
2 to 15
1.772
1.378
1.260
0.906 0.079 to 0.591
1 to 19
1 to 18
1 to 18
1.5 to 16
2 to 15
0.039 to 0.748 0.039 to 0.709 0.039 to 0.709 0.059 to 0.630 0.079 to 0.591
1.5 to 15
2 to 15
2 to 15
3 to 14
4 to 14
0.059 to 0.591 0.079 to 0.591 0.079 to 0.591 0.118 to 0.551 0.158 to 0.551
0 to 31
0 to 28
0 to 27
0 to 24
0 to 24
0 to 1.220
0 to 1.102
0 to 1.063
0 to 0.945
0 to 0.945
0 to 30
0 to 30
0 to 30
0 to 29
0 to 28
0 to 1.181
0 to 1.181
0 to 1.181
0 to 1.142
0 to 1.102
0 to 43
0 to 43
0 to 43
0 to 43
0 to 42
0 to 1.693
0 to 1.693
0 to 1.693
0 to 1.693
0 to 1.654
3 to 35
4 to 33
4 to 33
4 to 33
4 to 32
0.118 to 1.378 0.157 to 1.299 0.157 to 1.299 0.157 to 1.299 0.157 to 1.260
0 to 110
0 to 87
0 to 74
0 to 56
1 to 38
0 to 4.331
0 to 3.425
0 to 2.913
0 to 2.205 0.039 to 1.496
530
310
260
170
85
20.866
12.205
10.236
6.693
3.346
170
110
92
45
30
6.693
4.331
3.622
1.772
1.181
84
44
33
19
11
3.307
1.732
1.299
0.748
0.433
130
90
70
38
23
5.118
3.543
2.756
1.496
0.906
710
430
320
210
100
27.953
16.929
12.598
8.268
3.937
1,100
600
550
290
190
43.307
23.622
21.654
11.417
7.480
160
990
610
435
280
11.024
6.299
38.976
24.016
17.126
190
130
110
80
37
7.480
5.118
4.331
3.150
1.457
600
330
250
160
80
23.622
12.992
9.843
6.299
3.15
515
290
220
125
80
20.276
11.417
8.661
4.921
3.15
1,200
790
660
420
220
47.244
31.102
25.984
16.535
8.661
0 to 4
0 to 0.157
0 to 8
0 to 0.315
0.5 to 4
0.020 to 0.157
5 to 9
0.197 to 0.354
3 to 12
0.118 to 0.472
6.5 to 10
0.256 to 0.394
0 to 18
0 to 0.709
1.5 to 24
0.059 to 0.945
0 to 29
0 to 1.142
5 to 25
0.197 to 0.984
27
1.063
9
0.354
3
0.118
7
0.276
34
1.339
65
2.559
50
1.969
11
0.433
25
0.984
25
0.984
75
2.953
0 to 4.5
0 to 0.177
0 to 8
0 to 0.315
1 to 4.5
0.039 to 0.177
5 to 15
0.197 to 0.591
3 to 15
0.118 to 0.591
7 to 12
0.276 to 0.472
0 to 19
0 to 0.748
0 to 28
0 to 1.102
0 to 40
0 to 1.575
5 to 30
0.197 to 1.181
16 to 30
0.630 to 1.181
45
1.772
20
0.787
7
0.276
17
0.669
60
2.362
110
4.331
85
3.346
25
0.984
45
1.772
35
1.378
120
4.724
Dimensions
P.60
P.60
P.60
P.60
P.60
P.60
P.61
P.61
P.61
P.61
P.61
P.61
P.61
0 to 5.5
0 to 0.217
0 to 9
0 to 0.354
0.5 to 7
0.020 to 0.276
1 to 30
0.039 to 1.181
1.5 to 16
0.059 to 0.630
3 to 14
0.118 to 0.551
0 to 25
0 to 0.984
0 to 30
0 to 1.181
0 to 50
0 to 1.969
4 to 33
0.157 to 1.299
0 to 50
0 to 1.969
150
5.906
68
2.677
22
0.866
60
2.362
170
6.693
240
9.449
185
7.283
70
2.756
155
6.102
140
5.512
345
13.583
P.62
P.62
P.62
P.62
P.62
P.62
P.62
P.62
P.62
P.62
P.63
P.63
P.63
P.63
P.63
P.63
P.63
P.63
P.63
P.64
P.64
P.64
Notes: 1) N
ote that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range of reflective type is the value for white non-glossy paper (as for FD-H30-L32 and FD-H18-L31 50 × 50 mm 1.969 × 1.969 in glass
substrate).
3) The sensing range is specified for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm
t0.079 in) [FD-L10: silicon wafers 100 × 100 mm 3.937 × 3.937 in].
4) Sold
as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
5) Liquid
inflow prevention joint, protective tube extension joint, fiber mounting joint are available. Please refer to page 35 for details.
41
Fibers are listed in alphabetic order.
Refer to p. 2~ for details of each fiber.
SENSING RANGE
New product
introduction
Tough
Fiber
Reflective type
Sensing range (mm in) (Note 1, 2)
FX-500 series
Model No.
HYPR
FD-S32W
FD-S33GW
FD-S60Y
FD-V30
FD-V30W
FD-V50
FD-Z20HBW
FD-Z20W
FD-Z40HBW
FD-Z40W
FD-Z50HW (Note 3)
U-LG
LONG
STD
FX-100 series
FAST
H-SP
900
630
430
270
150
45
35.433
24.803
16.929
10.630
5.906
1.772
670
340
280
150
90
25
26.378
13.386
11.024
5.906
3.543
0.984
600
590
420
320
200
75
23.622
23.228
16.535
12.598
7.874
2.953
240
130
120
65
35
14
9.449
5.118
4.724
2.559
1.378
0.551
80
40
30
20
10
2
3.150
1.575
1.181
0.787
0.394
0.079
370
220
210
120
75
25
14.567
8.661
8.268
4.724
2.953
0.984
1 to 340
1 to 210
1 to 180
2 to 85
2 to 55
3 to 15
0.039 to 13.386 0.039 t 8.268 0.039 to 7.087 0.079 to 3.346 0.079 to 2.165 0.118 to 0.591
260
150
130
1 to 65
2 to 45
5 to 13
10.236
5.906
5.118 0.039 to 2.559 0.079 to 1.772 0.197 to 0.512
760
540
470
260
1 to 160
2 to 50
29.921
21.260
18.504
10.236 0.039 to 6.299 0.079 to 1.969
790
440
390
190
1 to 120
2 to 35
31.102
17.323
15.354
7.480 0.039 to 4.724 0.079 to 1.378
10 to 2,500
10 to 1,100
10 to 1,000
10 to 650
10 to 410
15 to 130
0.394 to 98.425 0.394 to 43.307 0.394 to 39.370 0.394 to 25.591 0.394 to 16.142 0.591 to 5.118
FX-101
FX-102
80
3.150
45
1.772
140
5.512
25
0.984
6
0.236
40
1.575
2 to 30
0.079 to 1.181
2 to 32
0.079 to 1.260
1 to 90
0.039 to 3.543
1 to 74
0.039 to 2.913
10 to 200
0.394 to 7.874
230
9.055
140
5.512
300
11.811
75
2.953
20
0.787
100
3.937
1 to 90
0.039 to 3.543
1 to 80
0.039 to 3.150
0.5 to 240
0.020 to 9.449
200
7.874
10 to 530
0.394 to 20.866
Dimensions
Fiber
Selection
Guide
Model
P.64
P.64
P.64
P.64
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
P.64
P.65
P.65
P.65
P.65
Fibers
Super
Quality
Threaded
Type
P.65
Square Head
Type
P.65
Cylindrical
Type
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper (except for FD-Z50HW).
3) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.
Refer to P.38 for the sensing range when FR-Z50HW is used in combination with a reflector (optional).
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
42
New product
introduction
Tough
Fiber
FIBER OPTIONS
Refer to p.66~ for details of lens dimensions.
Lens (For thru-beam type fiber)
Designation Model No.
Description
Increases the sensing range by 5 times or more. • Ambient temperature: -60 to +350 °C -76 to +662 °F (Note 4) • Beam dia: ø3.6 mm ø0.142 in
Sensing range (mm in) [Lens on both sides]
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
FT-43
FX-500 series
HYPR
U-LG
LONG
STD
FAST
3,600
3,600
3,600
3,600
3,600
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
H-SP
1,600
62.992
FX-100 series
FX-101
FX-102
2,400
3,600
94.488 141.732 (Note 2)
FT-42
FT-42W
3,600
3,600
3,600
3,600
3,600
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
2,200
86.614
3,400
3,600
133.858 141.732 (Note 2)
FT-45X
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
1,600
62.992 (Note 2)
1,500
1,600
1,600
59.055 62.992 (Note 2) 62.992 (Note 2)
1,900
3,100
3,600
74.803
122.047 141.732 (Note 2)
2,200
3,400
3,600
86.614
133.858 141.732 (Note 2)
670
1,300
3,600
26.378
51.181 141.732 (Note 2)
1,400
2,000
3,500
55.118
78.740 137.795 (Note 2)
850
1,300
1,600
33.465
51.181 62.992 (Note 2)
1,200
1,600
1,600
47.244 62.992 (Note 2) 62.992 (Note 2)
Fiber
Expansion
lens
(Note 1)
FX-LE1
Amplifier
Mode
FT-R40
FT-R42W
FT-R43
FT-H35-M2
Fibers
FT-H20W-M1
Super
Quality
FT-H20-M1
FT-H20-J50-S
FT-H20-J30-S
FT-H20-J20-S
Threaded
Type
Square Head
Type
Sleeve
Flat
Type
Narrow
Beam
Wide
Beam
Superexpansion
lens
(Note 1)
FX-LE2
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Side-view
lens
Fiber
Dimensions
Thru-beam
Type
FX-500
series
FX-100
series
INDEX
3,500
137.795
2,000
78.740
1,600
62.992
500
19.685
1,000
3,500
39.370 137.795 (Note 2)
Expansion
lens for
vacuum
fiber
(Note 1)
Vacuumresistant
side-view
lens
(Note 1)
Amplifier
Mode
HYPR
Fiber
FT-43
3,600
FT-42
141.732 (Note 2)
FT-42W
1,600
FT-45X
62.992 (Note 2)
3,600
FT-R40
141.732 (Note 2)
3,600
FT-R42W
141.732 (Note 2)
3,600
FT-R43
141.732 (Note 2)
3,600
FT-H35-M2
141.732 (Note 2)
FT-H20W-M1
1,600
62.992 (Note 2)
FT-H20-M1
U-LG
FX-500 series
LONG
STD
FAST
H-SP
FX-100 series
FX-101
FX-102
3,600
3,600
3,600
3,600
3,600
3,600
3,600
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,500
137.795 (Note 2)
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,500
137.795 (Note 2)
1,600
1,600
1,600
1,600
1,600
1,600
1,600
62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2)
FT-H13-FM2
3,600
3,600
3,600
3,600
3,600
3,600
3,500
3,500
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 (Note 2) 137.795 (Note 2)
FT-H20-J50-S
FT-H20-J30-S
FT-H20-J20-S
3,600
3,600
3,600
3,600
3,600
3,600
3,500
3,500
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 (Note 2) 137.795 (Note 2)
FV-LE1
Semi-custom
fibers
Amplifiers
3,600
3,600
141.732 (Note 2) 141.732 (Note 2)
Sensing range increases by 4 times or more. • Ambient temperature: -60 to +350 °C -76 to +662 °F (Note 4) • Beam dia: ø3.6 mm ø0.142 in
Sensing range (mm in) [Lens on both sides] (Note 3)
FX-500 series
FX-100 series
Amplifier
Mode
HYPR
U-LG
LONG
STD
FAST
H-SP
FX-101
FX-102
Fiber
3,600
3,600
3,400
1,500
900
370
450
1,600
FT-H30-M1V-S
141.732 (Note 2) 141.732 (Note 2)
133.858
59.055
35.433
14.567
17.717
62.992
Fiber
Options
Others
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,900
74.803
3,300
129.921
1,600
62.992 (Note 2)
1,600
62.992 (Note 2)
FX-SV1
Liquid Leak /
Liquid Detection
Reflective
Type
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
1,600
62.992 (Note 2)
Beam axis is bent by 90°. • Ambient temperature: -60 to +300 °C -76 to +572 °F (Note 4) • Beam dia: ø2.8 mm ø0.110 in
Sensing range (mm in) [Lens on both sides]
FX-500 series
FX-100 series
Amplifier
Mode
HYPR
U-LG
LONG
STD
FAST
H-SP
FX-101
FX-102
Fiber
3,600
3,400
2,600
1,700
970
310
510
1,400
FT-43
141.732 (Note 2)
133.858
102.362
66.929
38.189
12.205
20.079
55.118
3,600
3,600
3,600
2,100
1,150
370
500
1,700
FT-42
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
82.677
45.276
14.567
19.685
66.929
3,600
3,500
2,700
1,800
990
320
480
1,300
FT-42W
141.732 (Note 2)
137.795
106.299
70.866
38.976
12.598
18.898
51.181
1,600
1,600
1,600
1,400
800
210
540
1,600
FT-45X
62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2)
55.118
31.496
8.268
21.260 62.992 (Note 2)
3,600
3,500
2,700
1,800
990
320
1,400
1,000
FT-R42W
141.732 (Note 2)
137.795
106.299
70.866
38.976
12.598
55.118
39.370
3,200
1,800
1,300
950
510
160
310
930
FT-R43
125.984
70.866
51.181
37.402
20.079
6.299
12.205
36.614
3,500
1,600
1,200
780
500
150
280
800
FT-H35-M2
137.795
62.992
47.244
30.709
19.685
5.906
11.024
31.496
1,600
1,600
1,500
950
560
190
140
400
FT-H20W-M1
62.992 (Note 2) 62.992 (Note 2)
59.055
37.402
22.047
7.480
5.512
15.748
1,600
1,600
1,300
780
500
150
280
840
FT-H20-M1
62.992 (Note 2) 62.992 (Note 2)
51.181
30.709
19.685
5.906
11.024
33.071
FT-H20-J50-S
1,600
960
740
450
290
80
150
410
FT-H20-J30-S
62.992 (Note 2)
37.795
29.134
17.717
11.417
3.150
5.906
16.142
FT-H20-J20-S
Vacuumresistant
Retroreflective
Type
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
1,600
62.992 (Note 2)
Tremendously increases the sensing range with large diameter lenses. • Ambient temperature: -60 to +350 °C -76 to +662 °F (Note 4) • Beam dia: ø9.8 mm ø0.386 in
Sensing range (mm in) [Lens on both sides]
Cylindrical
Type
Small
Spot
1,600
62.992 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
3,600
141.732 (Note 2)
1,600
62.992 (Note 2)
1,600
62.992 (Note 2)
Beam axis is bent by 90°. • Ambient temperature: -60 to +300 °C -76 to +572 °F (Note 4) • Beam dia: ø3.7 mm ø0.146 in
Sensing range (mm in) [Lens on both sides] (Note 3)
FV-SV2
Amplifier
Mode
HYPR
U-LG
3,600
3,600
FT-H30-M1V-S
141.732 (Note 2) 141.732 (Note 2)
Fiber
FX-500 series
LONG
STD
3,400
1,500
133.858
59.055
FAST
900
35.433
H-SP
370
14.567
FX-100 series
FX-101
FX-102
450
1,600
17.717
62.992
Notes: 1) Be careful sure to use it only after you have adjusted it sufficiently when installing the thru-beam type fiber equipped with the expansion lens, as the
beam envelope becomes narrow and alignment is difficult.
2) The fiber cable length practically limits the sensing range.
3) The fiber cable length for the FT-H30-M1V-S is 1 m 3.28 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series and in FX-102 are specified considering the length of the FT-J8 atmospheric side fiber.
4) Refer to p.12, p.15, p.30 and p.32 for the ambient temperature of fibers to be used in combination.
43
FIBER OPTIONS
Refer to p.66~ for details of lens dimensions.
Tough
Fiber
Lens (For reflective type fiber)
Designation
Model No.
Description
Pinpoint spot of ø0.5 mm ø0.020 in. Enables detection of minute objects or small marks.
Pinpoint
spot lens
FX-MR1
• Distance to focal point: 6 ± 1 mm 0.236 ± 0.039 in
• Applicable fibers: FD-42G, FD-42GW
• Ambient temperature: -40 to +70 °C -40 to +158 °F (Note)
The spot diameter is adjustable from ø0.7 to ø2 Sensing range for FX-500/FX-100 series
mm ø0.028 to ø0.079 in according to how much
Screw-in depth Distance to focal point Spot diameter
the fiber is screwed in.
• Applicable fibers: FD-42G, FD-42GW
7 mm
18.5 mm approx. ø0.7 mm
• Ambient temperature:-40 to +70 °C
27 mm approx.
ø1.2 mm
12 mm
-40 to +158 °F (Note)
Spot
• Accessory: MS-EX3 (mounting bracket)
43
mm
approx.
ø2.0
mm
14
mm
diameter
Screw-in
depth
FX-MR2
For reflective type fiber
Zoom lens
Finest spot
lens
Distance to
focal point
FX-MR3
Distance to
focal point
Spot diameter
Finest spot
lens
FX-MR6
Extremely fine spot of ø0.15 mm ø0.006 in
approx. achieved.
• Applicable fibers:
FD-EG31, FD-EG30, FD-42G, FD-42GW,
FD-32G, FD-32GX
• Ambient temperature: -40 to +70 °C
-40 to +158 °F (Note)
Sensing range for FX-500/FX-100 series
Extremely fine spot of ø0.1 mm ø0.004 in
approx. achieved.
• Applicable fibers:
FD-EG31, FD-EG30, FD-42G, FD-42GW,
FD-32G, FD-32GX
• Ambient temperature: -20 to +60 °C
-4 to +140 °F (Note)
Sensing range for FX-500/FX-100 series
Screw-in FX-MR2 is converted into a side-view type and
depth
can be mounted in a very small space.
• Applicable fibers: FD-42G, FD-42GW
• Ambient temperature: -40 to +70 °C
-40 to +158 °F (Note)
Zoom lens
side-view
type
FX-MR5
Distance to
focal point
Spot diameter
Fiber model No. Distance to focal point Spot diameter
For Square head M3 reflective fiber
Lens
Shape
(mm in)
Model No.
Shape
7 ± 0.5
0.276 ± 0.020 ø5 ø0.197
15.3
0.602
FX-MR7
ø0.4 ø0.016
approx.
Parallel
light lens
Zoom lens
Type
For Square head M3
reflective fiber
Distance to
focal point
(mm in)
ø0.15 ø0.006
approx.
Finest spot
lens
Spot diameter
(mm in)
Sensing
range
(mm in)
Lens
Shape
(mm in)
ø0.4 to ø2.0 ø0.016 to ø0.079 approx.
ø0.4 to ø2.2 ø0.016 to ø0.087 approx.
10 to 30
ø5 ø0.197
ø0.5 to ø2.5 ø0.020 to ø0.098 approx. 0.394 to1.181
ø4.0 ø0.157 approx.
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
7.5 ± 0.5 mm ø0.15 mm approx.
FD-EG30
7.5 ± 0.5 mm ø0.3 mm approx.
Threaded
Type
FD-42G/42GW
7.5 ± 0.5 mm ø0.5 mm approx.
FD-32G/32GX
Square Head
Type
Cylindrical
Type
Fiber model No. Distance to focal point Spot diameter
Sleeve
FD-EG31
7 ± 0.5 mm
ø0.1 mm approx.
FD-EG30
7 ± 0.5 mm
ø0.2 mm approx.
Flat
Type
FD-42G/42GW
FD-32G/32GX
7 ± 0.5 mm
ø0.4 mm approx.
Sensing range for FX-500/FX-100 series
Screw-in depth Distance to focal point Spot diameter
8 mm
13 mm approx.
ø0.5 mm
10 mm
15 mm approx.
ø0.8 mm
14 mm
30 mm approx.
ø3.0 mm
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Liquid Leak /
Liquid Detection
Model No.
ø0.125 ø0.005
FD-R33EG
ø0.125 ø0.005
FD-EG31
ø0.175 ø0.007
FD-R34EG
ø0.25 ø0.010
FD-R32EG
ø0.25 ø0.010
FD-EG30
ø0.5 ø0.020
FD-R31G
ø0.5 ø0.020
FD-32G
ø0.5 ø0.020
FD-32GX
ø0.5 ø0.020
FD-42G
ø0.5 ø0.020
FD-42GW
fiber
Model No. Emitting
core (mm in)
15
0.591
FX-MR8
10
0.394
ø5 ø0.197
Fiber
Emitting fiber
core (mm in)
Applicable fibers
ø0.8 to ø3.5 ø0.031 to ø0.138 approx.
0 to 30
0 to 1.181
Choose
by shape/
application
Heatresistant
ø0.1 ø0.004
approx.
ø0.2 ø0.008
approx.
Model
Vacuumresistant
Lens (For square head M3 reflective fiber)
Spot diameter
(mm in)
Fiber
Selection
Guide
FD-EG31
Note: Refer to p.13 or p.23 for the ambient temperature of fibers to be used in combination.
Type
New product
introduction
FX-MR9
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Model No.
ø0.125 ø0.005
FD-R33EG, FD-EG31
ø0.175 ø0.007
FD-R34EG
ø0.25 ø0.010
FD-R32EG, FD-EG30
ø0.5 ø0.020
FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW
ø0.125 ø0.005
FD-R33EG, FD-EG31
ø0.175 ø0.007
FD-R34EG
ø0.25 ø0.010
FD-R32EG, FD-EG30
ø0.5 ø0.020
FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW
Amplifiers
FX-500
series
FX-100
series
INDEX
44
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
FIBER OPTIONS
Model No. when ordering heat-resistant fibers individually as replacement parts
• FT-H20-J20 (one pair set)
• FT-H20-J30 (one pair set)
• FT-H20-VJ50 (one pair set)
• FT-H20-VJ80 (one pair set)
Model No. when ordering vacuum-resistant fibers individually as replacement parts
• Vacuum-resistant fiber
FT-H30-M1V (one pair set)
FD-H30-KZ1V
FD-H30-L32V
Earlier models
comparison
table
• Photo-terminal
FV-BR1 (one pair set)
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
• RF-003 (FR-KZ50E/KZ50H exclusive reflector)
• RF-13 (FR-Z50HW reflective tape)
• FX-CT2 (Fiber cutter)
• FX-CT3 (FD-H40Y/F41Y fiber cutter)
• FX-AT2 (Attachment for fixed-length fiber, Orange)
• FX-AT3 (Attachment for ø2.2 mm ø0.087 in fiber, Clear orange)
• FX-AT4 (Attachment for ø1 mm ø0.039 in fiber, Black)
• FX-AT5 (Attachment for ø1.3 mm ø0.051 in fiber, Gray)
• FX-AT6 Attachment for ø1 mm ø0.039 in / ø1.3 mm ø0.051 in
( mixed fiber, Black / Gray
• MS-FD-2 (Fiber mounting bracket)
• Mouting bracket for FD-H30-KZ1V(-S)
MS-FD-2
• Fiber at atmospheric side
FT-J8 (one pair set)
Model No. when ordering accessories additionally
Fibers
• FT-H20-J50 (one pair set)
)
• RF-003
• RF-13
• FX-AT2
• FX-AT3
• MS-FD-2
• FX-CT2
• FX-AT4
• FX-AT5
• FX-CT3
• FX-AT6
45
FIBER OPTIONS
New product
introduction
Others
Designation
Model No.
FTP-1000 (1 m 3.281 ft)
For M4
thread
FTP-1500 (1.5 m 4.921 ft)
FTP-N500 (0.5 m 1.640 ft)
FTP-N1000 (1 m 3.281 ft)
For M3
thread
Applicable fibers
Protective tube
for thru-beam
type fiber
FTP-N1500 (1.5 m 4.921 ft)
FDP-500 (0.5 m 1.640 ft)
FDP-1000 (1 m 3.281 ft)
Protective tube
for reflective
type fiber
• FTP-□
• FDP-□
Description
FTP-500 (0.5 m 1.640 ft)
For M6
thread
FDP-1500 (1.5 m 4.921 ft)
FDP-N500 (0.5 m 1.640 ft)
FDP-N1000 (1 m 3.281 ft)
FT-42
FT-42S
FT-42W
FT-43
FT-H13-FM2
FT-31
FT-31S
FT-31W
FD-31
FD-31W
Model
FD-41S
FD-41SW
• MS-AJ1-F
Universal sensor
mounting stand
(Note 2)
MS-AJ1-F
Horizontal mounting type
MS-AJ2-F
Vertical mounting type
Single core
holder
Applicable fibers
Fiber
mounting joint
(Note 2)
MS-FX-02Y
Mounting stand assembly for fiber (For M3,
M4 or M6 threaded head fiber)
This joint suppresses false operations
due to liquid slip-in from the top of the
protective tube.
The joint is used for mounting fibers on a
tank.
The incident light intensity may vary when using a multi-core fiber or a
thin type sharp bending fiber. This holder suppresses the variation in
the incident light intensity. (Brown)
FX-AT15A
Used with FR-Z50HW.
Refer to p.27 or p.38 for the sensing range of FR-Z50HW to be used
in combination.
RF-220
RF-230
Notes: 1) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter head type fiber.
2) The joint internal ferrule (MS-FX-YF) is available as a spare part. A distorted ferrule may result in leakage.
Liquid inflow prevention joint
MS-FX-01Y
• MS-FX-01Y
MS-FX-01Y
MS-FX-01Y
Protective tube extension joint
MS-FX-02Y
• MS-FX-02Y
MS-FX-02Y
MS-FX-02Y
Union nut
Body
Ferrule (MS-FX-YF)
Body
Body
Union
nut
Ferrule
(MS-FX-YF)
Ferrule (MS-FX-YF)
Union nut
MS-FX-03Y
• MS-FX-03Y
MS-FX-03Y
MS-FX-03Y
Body
Ferrule (MS-FX-YF)
Body
Body
Union
nut
Ferrule
(MS-FX-YF)
Union nut
11 mm
360°
rotation
20°
20°
Angle adjustment: ±20°
• RF-220
33.3 mm
Square Head
Type
Cylindrical
Type
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Forward / back
adjustment:
130 mm
5.118 in approx.
Height
adjustment:
150 mm 5.906 in
approx.
20°
20°
Angle adjustment: ±20°
Mounting hole
for M6 screw
Single core holder
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Union nut
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Ferrule (MS-FX-YF)
Union nut
8.3 mm
Threaded
Type
Convergent
Reflective
Type
360° rotation
Ferrule
(MS-FX-YF)
Union nut
Union nut
Ferrule
Body(MS-FX-YF)
Ferrule (MS-FX-YF)
Body
Height
adjustment:
150 mm 5.906 in
approx.
Mounting hole
for M6 screw
• MS-AJ2-F
• FX-AT15A
Super
Quality
Sleeve
Forward / back
adjustment:
130 mm
5.118 in approx.
Fiber mounting joint
Ferrule (MS-FX-YF)
Union nut
Union nut
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Body
Reflector
• RF-210
360° rotation
360°
rotation
RF-210
Reflector
The protective tube can be extended.
MS-FX-03Y
Fibers
Using the arm which enables adjustment in
the horizontal direction, sensing can also be
done from above an assembly line.
The fiber bender bends the sleeve part of the fiber head at the proper
radius. (Note 1)
FD-HF40Y
FD-F41Y
Earlier models
comparison
table
Universal sensor mounting stand
FB-1
Protective tube
extension joint
(Note 2)
How to read
Model No.
The protective
tube, made of noncorrosive stainless
steel, protects the
FD-62
inner fiber cable from
FD-H13-FM2 any external forces.
FD-61
FD-61G
FD-61S
FD-61W
MS-FX-01Y
Choose
by shape/
application
• FB-1
Fiber bender
Liquid inflow
prevention
joint
(Note 2)
Fiber
Selection
Guide
Fiber bender
FD-41
FD-41W
For M4
thread
FDP-N1500 (1.5 m 4.921 ft)
Union nut
Tough
Fiber
Protective tube
Others
• RF-230
50.3 mm
35.3 mm
12.8
mm
8.3 mm
Amplifiers
FX-500
series
42.3
mm
FX-100
series
59.3
mm
INDEX
46
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Semi-custom fibers that flexibly meet diverse needs
Guide to interchanging fiber length and sleeve length
Custom-ordered products are available with different fiber lengths and sleeve lengths in order to respond quickly to different
requirements.
Contact us more in formation.
Fiber length change
Sleeve length change
It is possible to extend up to 30 m 98.425 ft
in units of 1 m 3.281 ft, varying depending on
the model. Refer to the table on the next page
for applicable models.
Extension is possible up to 120 mm 4.724 in
in units of 10 mm 0.394 in. Applicable models
are sleeve extension-type models indicated by
in the table on the next page.
Fibers
Fiber cable length L
Super
Quality
Threaded
Type
Sleeve length ℓ
Square Head
Type
Note that the model number differs from
previous models with changed lengths.
Cylindrical
Type
Note that the model number differs from
previous models with changed lengths.
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
• Attenuation ratio characteristics for fiber cable length and sensing range
Note that the longer the fiber cable length, the shorter the sensing range.
Typical example: Bending radius R4 mm/R2 mm
(Tough fiber)
Typical example: Bending radius R1 mm
(Sharp bending fiber FT- □W/FD- □W)
1.0
1.0
Retroreflective
Type
0.9
0.9
Chemical / Oilresistant
0.8
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Bending radius R4 mm R0.157 in
Beam axis diameterφ1 mm φ0.039 in
Sensing range coefficient
Heatresistant
Sensing range coefficient
Convergent
Reflective
Type
0.7
0.6
0.5
0.4
Bending radius R2 mm R0.079 in
Beam axis diameterφ0.5 mm φ0.020 in
0.3
0.8
0.7
0.6
Bending radius R1 mm 0.0395 in
Beam axis diameterφ1 mm φ0.039 in
0.5
0.4
0.3
0.2
0.2
0.1
0.1 Bending radius R1 mm 0.0395 in
Beam axis diameterφ0.5 mm φ0.020 in
0
2
10
0
2
6.562
10
32.808
20
65.617
Fiber cable length L (m ft)
30
98.425
6.562
32.808
20
65.617
30
98.425
Fiber cable length L (m ft)
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Note: Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an
environment with varying humidity.
Extended protective tube
The chemical-resistant cover and stainless jacket can be extended in accordance with the fiber cable length.
Applicable models are indicated in the table as follows.
: Models which can have extended protective tube (fluorine resin)
: Models which can have extended stainless jacket sheath
Amplifiers
FX-500
series
FX-100
series
INDEX
Protective tube
Fiber
47
New product
introduction
Tough
Fiber
Applicable models
Thru-beam type
Reflective type
Applicable
fiber length
Basic specifications
Fiber cable
length
:
Free-cut
FT-140
10 m
FT-31
2m
FT-31S
2m
FT-31W
2m
FT-42
2m
FT-42S
2m
FT-42W
2m
FT-43
2m
FT-45X
1m
FT-A11
2m
FT-A11W
2m
FT-A32
2m
FT-A32W
2m
FT-AL05
2m
FT-E13
1m
FT-E23
1m
FT-F93
2m
FT-H13-FM2
2m
FT-H20-J50-S 500 mm
(Note 5)
FT-H20-M1
1m
FT-H20-VJ80-S 800 mm
(Note 5)
1m
FT-H20W-M1
FT-H30-M1V-S
1m
2m
FT-H35-M2
FT-H35-M2S6
2m
FT-HL80Y
2m
(Note 6)
2m
FT-KS40
FT-KV26
2m
FT-KV40
2m
FT-KV40W
2m
FT-L80Y
2m
(Note 6)
FT-R31
2m
2m
FT-R43
FT-R40
2m
FT-R41W
2m
2m
FT-R42W
FT-R44Y
2m
FT-R60Y
2m
FT-S11
500 mm
FT-S21
2m
2m
FT-S21W
FT-S31W
2m
FT-S32
2m
FT-V23
2m
2m
FT-V24W
FT-V25
2m
2m
FT-V30
FT-V40
2m
FT-V80Y
2m
(Note 6)
1m
FT-Z20HBW
FT-Z20W
1m
FT-Z30
2m
FT-Z30E
2m
FT-Z30EW
2m
FT-Z30H
2m
FT-Z30HW
2m
2m
FT-Z30W
FT-Z40HBW
2m
FT-Z40W
2m
FT-Z802Y
2m
Model No.
Protective
tube
extension
length
1 m (Note 4)
Sensing range
(mm)
FX-500 series
(STD)(Note 1)
19,600 (Note 2)
315
40 (Note 3)
315
260
1,130
40 (Note 3) 1,130
800
1,400
1,200
3,600 (Note 2)
3,600 (Note 2)
3,600 (Note 2)
3,600 (Note 2)
860
5
15
5
75
Sleeve
length
(mm)
1.5 m (Note 4)
1.5 m (Note 4)
20
15
15
20
1.5 m (Note 4)
700
470
540
600
470
270
430
430
3,600 (Note 2)
3,600 (Note 2)
710
3,600 (Note 2)
3,600 (Note 2)
3,600 (Note 2)
270
720
930
800
2,200
720
2,100
90
315
260
800
3,100
450
110
240
680
3,500
3,600 (Note 2)
260
620
2,100
3,500
3,400
3,500
3,500
1,500
800
1,500
3,100
Max. Unit
(m) (m)
30
30
30
20
30
30
30
30
10
10
10
10
10
20
10
10
30
30
6.5
6.5
6.5
6.5
6.5
6.5
6.5
30
10
10
10
10
30
30
30
30
30
30
30
30
30
30
20
30
30
30
10
30
30
30
30
20
20
30
30
20
30
20
20
20
20
30
1
1
1
1
1
1
1
1
0.5
1
1
1
1
1
0.5
0.5
1
1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Retroreflective type
Applicable
fiber length
Basic specifications
Model No.
FR-KZ22E
FR-KZ50E
FR-KZ50H
FR-Z50HW
Fiber cable
length
:
Free-cut
2m
2m
2m
2m
Protective
tube
extension
length
Sleeve
length
(mm)
Sensing range
(mm)
FX-500 series
(STD)(Note 1)
15 to 310
20 to 300
20 to 300
100 to 990
Max. Unit
(m) (m)
10
10
10
30
1
1
1
1
Applicable
fiber length
Basic specifications
Fiber cable
length
:
Free-cut
FD-31
2m
FD-31W
2m
2m
FD-32G
FD-32GX
1m
2m
FD-41
FD-41S
2m
FD-41SW
2m
2m
FD-41W
2m
FD-42G
FD-42GW
2m
FD-61
2m
FD-61G
2m
FD-61S
2m
2m
FD-61W
FD-62
2m
1m
FD-64X
FD-A16
2m
2m
FD-AL11
FD-E13
1m
FD-E23
1m
FD-EG30
500 mm
FD-EG30S
1m
FD-EG31
500 mm
FD-F4
2m
FD-F41
2m
FD-F71
5m
2m
FD-FA93
FD-H13-FM2
2m
FD-H18-L31
2m
FD-H20-21
1m
FD-H20-M1
1m
FD-H25-L43
3m
FD-H25-L45
3m
FD-H30-KZ1V-S
1m
FD-H30-L32
2m
FD-H30-L32V-S
3m
FD-H35-20S
1m
FD-H35-M2
2m
FD-H35-M2S6
2m
FD-L10
2m
FD-L11
2m
FD-L12W
1m
FD-L20H
2m
FD-L21
2m
FD-L21W
2m
FD-L22A
2m
FD-L23
3m
FD-L30A
3m
FD-L31A
3m
FD-L32H
4m
FD-R31G
2m
FD-R32EG
500 mm
500 mm
FD-R33EG
FD-R34EG
500 mm
FD-R41
2m
FD-R60
2m
FD-R61Y
2m
FD-S21
1m
FD-S31
2m
FD-S32
2m
FD-S32W
2m
FD-S33GW
2m
FD-S60Y
2m
(Note 6)
FD-V30
2m
2m
FD-V30W
2m
FD-V50
FD-Z20HBW
1m
FD-Z20W
1m
FD-Z40HBW
2m
FD-Z40W
2m
FD-Z50HW
2m
Model No.
Protective
tube
extension
length
Sensing range
Max. Unit
(mm)
FX-500 series (m) (m)
(STD)(Note 1)
125
30 1
80
20 1
200
30 1
300 mm (Note 4)
200
30 1
125
30 1
40 (Note 3)
125
30 1
40 (Note 3)
80
20 1
270
20 1
200
30 1
150
20 1
450
30 1
420
30 1
40 (Note 3)
420
30 1
270
30 1
520
30 1
280
10 0.5
200
30 1
320
20 1
3
12
3 0.1
5
55
3 0.1
48
3 0.1
15
50
3 0.1
20
3 0.1
10 1
10 1
3 m (Note 4)
20 1
10 1
350
30 1
16
5
1
230
6.5 0.1
330
6.5 0.1
1.5 to 26 6.5 0.1
5 to 42 6.5 0.1
20 to 200 6.5 0.1
17
5
1
8
6.5 0.1
260
6.5 0.1
260
6.5 0.1
260
6.5 0.1
0 to 5
5
1
0 to 9.5
5
1
8
5
1
30
5
1
1.5 to 16 5
1
3 to 14
5
1
0 to 24
5
1
0 to 29
5
1
0 to 43
5
1
4 to 33
5
1
0 to 56
5
1
170
30 1
45
3 0.1
19
3 0.1
38
3 0.1
210
30 1
290
30 1
280
30 1
80
20 1
125
30 1
420
30 1
270
20 1
150
20 1
1.5 m (Note 4)
320
30 1
15
65
30 1
15
20
10 1
20
120
30 1
2 to 85 20 1
1 to 65 20 1
260
20 1
190
20 1
10 to 650 30 1
Sleeve
length
(mm)
: Models which can have extended sleeve
: Models which can have extended protective tube (fluorine resin)
: Models which can have extended stainless jacket sheath
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
3) Applicable sleeve lengh is from 10 to 120 mm 0.394 to 4.724 in and in units of 10 mm 0.394 in.
4) Applicable protective lengh is up to 10 m 32.808 ft and in units of 0.5 m 1.640 ft. (however, FD-32GX is in units of 0.1 m 0.328 ft.)
5) Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut).
6) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted.
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
48
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
DIMENSIONS (Unit: mm in)
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Thru-beam type fibers
FT-140
Free-cut
ø23 ø0.906
19 0.748
ø10
ø0.394
ø10 ø0.394 Lens (PMMA)
17
23 0.906
0.669
8 8
3.5
0.315 0.315
0.138
Holder (ABS)
Toothed lock washer M14
[Iron (Chromed)]
Free-cut
2
0.079
ø6.5
ø0.256
10
0.394
Narrow
Beam
Wide
Beam
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
ø1
ø0.039
Retroreflective
Type
Reflective
Type
(ø2) (ø0.079) Model No. tube (m-PPE)
ø6.5
ø0.256
2.7
0.106
10
0.394
2
5.5 0.079
0.217
2,000 78.740
1.8 0.071
(30)(1.181)
Hexagon nut M3
[Stainless steel(SUS304)]
1.8 0.071
(30)
(1.181)
FT-42
Free-cut
FT-140
3
0.118
1 0.039
ø2
3.5 0.138
ø0.079
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Hexagon nut M3
[Stainless steel (SUS304)]
M3 × 0.5 0.020
FT-40
ø8.5
ø0.335
3.5
0.138
3 0.118
2.4 0.094
ø2
ø0.079
2,000
78.740
Resin plug (ABS)
(ø4.33)
(20) ø2.2 (ø0.170)
(0.787) ø0.087
12
0.472
1
0.039
ø4 ø0.157 -0.10 -0.004
-0.13 -0.005
Mounting reference surface (Screw periphery)
End bracket [Brass (Nickel plated)]
FT-31S
(19.7)
(0.776) 10.2
0.402
(0.3)
(0.012)
ø2.2 ø1.8
(ø3.2) (ø0.126) Model No. tube (m-PPE) ø0.087 ø0.071
Toothed lock washer M4 [Brass (Nickel plated)]
Opposing faces 7 0.276 thickness 2.4 0.094 [Brass (Nickel plated)]
M4 × 0.7 0.028
FT-42S
Free-cut
12
0.472
2.4 0.094
2,000
78.740
ø2.2
ø0.087
(30)
(1.181)
ø1 ø0.039 fiber core × 1 (Acrylic)
Sheath ø2.2 ø0.087 (Polyethylene)
ø4 ø0.157 -0.1 0.004
-0.13 0.005
Mounting reference surface (Screw periphery)
End bracket [Stainless steel(SUS303)]
(ø3.2) (ø0.126) Model No. tube (m-PPE)
Toothed lock washer M4 [Stainless steel(SUS304)]
Opposing faces 7 0.276 thickness 2.4 0.094 [Stainless steel(SUS304)]
M2.6 × 0.45 0.018
M4 × 0.7 0.028
FT-42W
Free-cut
ø8.5
ø0.335
7
0.276
3.5
0.138
12
0.472
40 1.575
Allowable
10 bending 10
0.394 range 0.394
5
0.197
2,000 78.740
2.4
0.094
ø2.5 ø0.098
ø1.48 ø0.058
Sleeve [Stainless steel (SUS304)] M4 × 0.7 0.028
Toothed lock washer M4 [Stainless steel (SUS304)]
Hexagon nut M4
[Stainless steel (SUS304)]
(30)
(1.181)
12
0.472
2,000 78.740
2.4
0.094
(30)
(1.181)
ø2.2 ø0.087
ø2
-0.1 -0.004
ø4 ø0.157 -0.13 -0.005 ø0.079
Mounting reference surface
(Screw periphery) M2.6 × 0.45FT-31W
0.018
M4 × 0.75 0.030
Toothed lock washer M4 [Stainless steel (SUS304)]
(ø3.2)(ø0.126) Model No. tube (m-PPE)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
End bracket [Stainless steel (SUS303)]
Hexagon nut M4
[Stainless steel (SUS304)]
ø2.2
ø0.087
(ø3.2)(ø0.126) Model No. tube (m-PPE)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
End bracket [Stainless steel (SUS303)]
FT-43
Free-cut
3
7 0.276 0.118
3.5 0.138 1
0.039
ø1 ø0.039
(ø2)(ø0.079) Model No. tube (m-PPE)
ø2 ø0.079
M2.6 × 0.45 0.018
Amplifiers
INDEX
2,000 78.740
End bracket [Stainless steel (SUS303)]
ø1
ø0.039
(ø2)(ø0.079)Model No. tube(m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
End bracket [Stainless steel(SUS303)]
-0.1 -0.004
ø3 ø0.118 -0.13 -0.005
Mounting reference surface
(Screw periphery)
ø2 ø0.079
M3 × 0.5 0.020
Toothed lock washer M3
[Stainless steel(SUS304)]
ø8.5
ø0.335
FX-100
series
5
0.197
Toothed lock washer M3 [Stainless steel (SUS304)]
Opposing faces 5.5 0.217 thickness 1.8 0.071 [Stainless steel (SUS304)]
Free-cut
Allowable
10 bending 10
0.394 range 0.394
ø0.88
ø0.035
Sleeve
[Stainless steel (SUS304)]
Toothed lock washer M3 [Stainless steel (SUS304)]
Others
FX-500
series
2.7
0.106
10
0.394
40 1.575
5.5
0.217
Semi-custom
fibers
Thru-beam
Type
Free-cut
ø6.5
ø0.256
FT-31W
ø8.5
ø0.335
Fiber
Dimensions
Opposing faces 5.5 0.217 thickness 1.8 0.071 [Brass (Nickel plated)]
FT-31S
ø0.5 ø0.020 fiber core × 1 (Acrylic)
Sheath ø1 ø0.039 (Polyethylene)
ø3 ø0.118 -0.10 -0.004
-0.13 -0.005
Mounting reference surface (Screw periphery)
End bracket [Stainless steel (SUS303)]
M3 × 0.5 0.020
Convergent
Reflective
Type
Retroreflective
Type
0.402
(0.3)
(0.012)
ø2.2 ø1.8
(ø2) (ø0.079) Model No. tube (m-PPE) ø0.087 ø0.071
Toothed lock washer M3 [Brass (Nickel plated)]
ø3 ø0.118 -0.10 -0.004
-0.13 -0.005
Mounting reference surface (Screw periphery)
End bracket [Brass (Nickel plated)]
2,000
78.740
1.8
0.071
(30)
(1.181)
Sleeve
Small
Spot
(19.7)
(0.776) 10.2
ø2
ø0.079
2.7
0.106
2,000
78.740
1.8 Resin plug(ABS)
0.071
ø1 (ø4.33)(ø0.170)
(20)
(0.787) ø0.039
10
0.394
M3 × 0.5 0.020
FT-31
Cylindrical
Type
Flat
Type
ø2.2 ø0.087
(30)
(1.181)
Hexagon nut M14
[Brass (Nickel plated)]
Threaded
Type
Square Head
Type
2
ø6.5
ø0.256 0.079
2.7
0.106 ø2
ø0.079
10,000 393.701
(ø3.2)(ø0.126) Model No. tube (m-PPE)
ø4.5
ø0.177
ø1 ø0.039 fiber core × 1 (PMMA)
ø7 ø0.276 Sheath ø2.2 ø0.087 (Polyethylene)
Protector (PVC)
M14 × 1 0.039
Fibers
Super
Quality
FT-30
How to read
Model No
Earlier models
comparison
table
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
ø8.5
ø0.335
7 0.276
3.5 0.138
3
0.118
1
0.039
2,000 78.740
12
0.472
ø2
-0.1 -0.004
ø4 ø0.157 -0.13 -0.005
ø0.079
Mounting reference surface
(Screw periphery)
M4 ×
M2.6 × 0.45 0.018
0.7 0.028
Toothed lock washer M4 [Stainless steel (SUS304)]
2.4
0.094
(30)
(1.181)
ø2.2
ø0.087
(ø3.2)(ø0.126) Model No. tube (m-PPE)
ø1.5 ø0.059 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
End bracket [Stainless steel (SUS303)]
Hexagon nut M4
[Stainless steel (SUS304)]
49
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Thru-beam type fibers
FT-45X
FT-A11
4.2
0.165
(13.5) 9.5 0.374
(0.531)
FT-A11W
Free-cut
Lens (Norbornene resin)
Sensing face (2.2 × 11) (0.087 × 0.433)
57
FT-A32
Free-cut
Center of beam axis
27 1.063
Beam axis
(8)(0.315)
2,000 78.740
4 0.157
5.2 0.205
ø1.3 ø0.051
(13.5) 9.5
(0.531) 0.374
4R
0.1
57
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
2-ø3.2 ø0.126 ø6.0 ø0.236
countersinking (on both sides)
Enclosure (PC)
4 19 0.748
0.157
2-R
5
0.197
16
(20) 0.630
(0.787)
4
FT-A32W
Free-cut
12
0.472
2-ø3.2 ø0.126 ø6 ø0.236
countersinking (on both sides)
45 1.772
FT-AL05
Free-cut
FT-45X
Center of beam axis
19 0.748
5
0.197
Sensing face (3.2 × 32) (0.126 × 1.260)
Lens (Norbornene resin)
4 0.157
65 2.559
2,000 78.740
Beam Enclosure (PC)
5.2
axis
0.205
ø1.3
ø0.051
7.3 0.287
(19)
(0.748)
16
(20) 0.630
(0.787)
.157
12
0.472
FT-E13
Free-cut
1,000
39.370
15
0.591
2-M3 × 0.5 0.020
15 10 0.394
0.591
FT-E23
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Free-cut
Fiber
Options
15
0.591
5±0.5
0.197±0.020
(ø2) (ø0.079) Model No. tube (m-PPE)
End bracket [Stainless steel (SUS303)]
1,000
39.370
(30)
(1.181)
ø1
ø0.039
ø0.25 ø0.010 fiber core ×1 (PMMA)
Semi-custom
fibers
Free-cut
Beam-emitting side
(Gray)
3
0.118
7.2 0.283
6 0.236
Enclosure
(ABS)
6 0.236
Beam-receiving side
(Black)
ø0.25 ø0.010 × 4 fiber core (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
ø3.1 ø0.122 Protective tube [PFA(Fluorine resin)]
ø3.1 ø0.122
ø1.5 ø0.059
fiber core × 1
Retroreflective
Type
Free-cut
3.5
0.138
Thru-beam
Type
Others
FT-H13-FM2
2,000 78.740
2-ø1 ø0.039
Fiber
Dimensions
Reflective
Type
0 0
ø0.4 ø0.016 -0.1 -0.004
FT-F93
1,000
39.370
ø0.5 ø0.020 × 1 fiber core (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
0 0
Details of
(ø2) (ø0.079) Model No. tube (m-PPE)
ø3 ø0.118 -0.1 -0.004
sensing part Mounting reference surface (Periphery)
ø0.25 ø0.010 0 0
-0.1 -0.004
FT-A32W
17 9 0.354
0.669
Square Head
Type
FT-A11
Sensing part (ø0.25 fiber core ø0.010 × 16)
ø0.125 ø0.005 fiber core × 1 (PMMA)
5.5 0.217
Threaded
Type
Sleeve [StainlessFT-A32
steel (SUS304)]
Details of
ø3 ø0.118 0 0
-0.1 -0.004
sensing part Mounting reference surface (Periphery)
10.3 0.406
Super
Quality
Liquid Leak /
Liquid Detection
ø0.5 ø0.020
fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
End bracket [Stainless steel (SUS303)]
23
0.906
ø0.25 ø0.010 fiber core × 16 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
5.25 0.207
Sleeve [Stainless steel (SUS304)]
20 0.787
12
0.472
ø2.2
ø0.087
4.5 0.177
Enclosure (PPS)
ø1
(30) ø0.039
(1.181)
5±0.5
0.197±0.020
Earlier models
comparison
table
Retroreflective
Type
2.5 0.098
2.5 0.098 4.5
Details of
0.177
sensing part 1 0.039
2-ø3.2 ø0.126 ø6 ø0.236
countersinking (on both sides)
45 1.772
FT-A11W
2,000 78.740
15 0.591
8
0.315
5 0.197
Head block
(LCP)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
4 R0
157
R0.
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Sensing face (3.2 × 32)(0.126 × 1.260) Lens (Norbornene resin)
4 0.157
65 2.559
2,000 78.740
Beam axis Enclosure (PC)
5.2 0.205
ø1.3
ø0.051
7.3 0.287
(19)
(0.748)
2-R
2-R
Center of beam axis
19 0.748
4 0.157
4.2 0.165
How to read
Model No.
Fibers
8
0.315
Choose
by shape/
application
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
2-ø3.2 ø0.126 ø6.0 ø0.236 countersinking (on both sides)
Enclosure (PC)
19
4
0.157 0.748
Fiber
Selection
Guide
Model
4 0.157
27 1.063
2,000 78.740
Beam axis
4 0.157
ø1.3
5.2 0.205
ø0.051
(8)
(0.315)
2R4
ø2.2 ø0.087
(ø4)(ø0.157)
Model No. tube (m-PPE) Resin plug (ABS)
Protective tube
Polyolefin tube included
SUS304 spiral tube
Crimping part
Lens (Norbornene resin)
Sensing face (2.2 × 11) (0.087 × 0.433)
8
0.315
.1
ø2 ø0.079
M4 × 0.7 0.028
Toothed lock washer M4
Details of
sensing part [Stainless steel (SUS304)]
3.5 0.138
Hexagon nut M4
[Stainless steel (SUS304)] End bracket
[Stainless steel
(SUS303)]
ø1 ø0.039 fiber core × 1 (PMMA)
ø8.5
ø0.335
Center of beam axis
R0
3 0.118
1 0.039
2.4 0.094
M2.6 × 0.45 0.018
7
0.276
1,000 39.370
19.7 0.776
(2.5)(0.098)
ø2.6 ø0.102
(ø4.33)(ø0.170)
(30)
10.2
(1.181)
0.402
Tough
Fiber
Free-cut
20 0.787
12
0.472
New product
introduction
13
0.512
12
0.472
ø3
ø0.118
M4 × 0.7 0.028
Screw tightening face
2,000
78.740
Amplifiers
FX-500
series
FX-100
series
ø2.2 ø0.087
(Fluorine resin)
Opposing faces 7 0.276, thickness 2.4 0.094
Toothed lock washer ø8.5 ø0.335
INDEX
50
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Thru-beam type fibers
FT-H20-J20-S FT-H20-J30-S FT-H20-J50-S
Free-cut (Note)
Heat-resistant side unit diagram (side view)
3 0.118
2.5 0.098
M2.6 × 0.45 0.018
M4 × 0.7 0.028
End bracket
[Brass (nickel plated)]
B
(25.8) (1.016)
17
0.669
6 0.236
Threaded
Type
30
1.181
ø2.2
ø0.087
(ø3.2) (ø0.126)
Model No. tube (m-PPE)
M4 × 0.7 0.028
Opposing faces 7 0.276,
ø1 ø0.039 fiber core × 1 (Acrylic)
thickness 3.2 0.126
Outer sheath ø2.2 ø0.087 (Polyethylene)
(Polypropylene)
Sleeve
Model No.
A
B
185 +30
0
Small
Spot
FT-H20-J20-S
200 +25
0
Narrow
Beam
FT-H20-J30-S
300 +25
11.811 +0.984
0
0
285 +30
11.221 +1.181
0
0
FT-H20-J50-S
500 +25
19.685 +0.984
0
0
+1.181
485 +30
0 19.095 0
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
7.284 +1.181
0
Note: Ordinary temperature side fiber (FT-42) only.
FT-H20-M1
20
0.787
3 0.118
3.5
0.138
9.3
0.366
ø3.5 ø0.138
5.4
0.213 Lock nut (polycarbonate)
Ordinary temperature side fiber (FT-42) connection diagram (front view)
8 0.315
2.2 0.087
2,000 78.740
(25.8) (1.016)
30
17
1.181
0.669
6 0.236 M4 × 0.7 0.028
B
24 0.945
12
0.472
Set screw
tightening range
ø2.2
ø0.087
Head [Brass (Nickel plated)]
(ø3.2) (ø0.126)
Model No. tube (m-PPE)
Spring washer [Stainless steel (SUS)]
Opposing faces 7 0.276,
ø1 ø0.039 fiber core × 1 (Acrylic)
thickness 3.2 0.126
Holder
Outer sheath ø2.2 ø0.087 (Polyethylene)
(Polypropylene)
[Brass (Nickel plated)]
Prism (BK7)
Model No.
A
B
FT-H20-VJ50-S
500 +25
19.685 +0.984
0
0
+1.969
800 +50
31.496
0
0
485 +30
19.095 +1.181
0
0
+55
785 0 30.906 +2.165
0
FT-H20-VJ80-S
Note: Ordinary temperature side fiber (FT-42) only.
1,000 39.370
Heat & cold-resistant Ordinary temperature
specifications
specifications
150
5.906
12
0.472
16.7
0.657
ø5 ø0.197 Fixing bracket [Brass (nickel plated)]
Screw tightening face
M2.6 × 0.45 0.018
M4 × 0.7 0.028
3
0.118
18.3
0.720
3.5
0.138
Fixing plug (PA)
Opposing faces 7 0.276, thickness 2.4 0.094
Toothed lock washer ø8.5 ø0.335
FT-H30-M1V-S
ø4
ø0.157
30 1.181
11
0.433
ø1.6
ø0.063
150
5.906
19.5
0.768
10
0.394
ø2.2
ø0.087
ø4.33 ø0.170 (PA)
Protective tube (PTFE)
Opposing faces 7 0.276, thickness 2.4 0.094
Toothed lock
washer ø8.5 ø0.335
ø3.6
ø0.142
Mounting cap nut opposing faces
8 0.315 [Stainless steel (SUS)]
Joint [Stainless steel (SUS)]
Liner+braid tube [Stainless steel (SUS)]
FT-H35-M2S6
2,000 78.740
Heat & cold-resistant Ordinary temperature
specifications
specifications
17
0.669
ø4 ø0.157
M2.6 × 0.45
0.018
M4 × 0.7
0.028
ø1.2 ø0.047 fiber
core bundle × 1
Note: The FT-H30-M1V-S is a set with the FT-H30-M1V, photo-terminal,
and atmospheric side fiber. Refer to p.66 for dimensions of the
atmospheric side fiber and photo-terminals.
150
5.906
27
1.063
17
0.669
2,000 78.740
16.7
0.657
18.3
0.720
ø2.2
ø5 ø0.197 Fixing bracket
ø0.087
[Brass (nickel plated)]
ø2.9 ø0.114 [Stainless steel (SUS)] Fixing plug (PA)
ø4 ø0.157 [Stainless steel (SUS)]
Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)]
Toothed lock washer ø8.5 ø0.335 [Stainless steel (SUS)]
18.3
0.720
Free-cut
Heat & cold-resistant Ordinary temperature
specifications
specifications
150
5.906
16.7
0.657
ø2.2
ø2.9 ø0.114
ø0.087
[Stainless steel (SUS)]
Fixing plug (PA)
ø4 ø0.157 [Stainless steel (SUS)] ø5 ø0.197 Fixing bracket
[Brass (Nickel plated)]
Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)]
Toothed lock washer ø8.5 ø0.335 [Stainless steel (SUS)]
FT-HL80Y
60
2.362
M4 × 0.7 0.028
[Stainless steel (SUS)]
27
1.063
4 0.157
End bracket
[Stainless steel (SUS)]
Toothed lock washer ø7.6 ø0.299
[Stainless steel (SUS)]
ø2.1 ø0.083 [Stainless steel (SUS)]
M4 × 0.7 0.028
3
0.118
1,000 39.370
Opposing faces 7 0.276,
thickness 3.2 0.126
[Stainless steel (SUS)]
ø1.2 ø0.047 fiber
5
core bundle × 1 0.197
Heat & cold-resistant Ordinary temperature
specifications
specifications
ø2.5
ø0.098
M2.6 × 0.45 0.018
ø0.8 ø0.031 fiber
core bundle × 1
1,000 39.370
FT-H35-M2
30 1.181
17
0.669
M2.6 × 0.45 0.018
M4 × 0.7 0.028
Screw tightening face
20
0.787
ø2.2
ø0.087
ø2.9 ø0.114 (Silicone)
ø4 ø0.157 [Brass (Nickel plated)]
ø1.1 ø0.043 fiber
core bundle × 1
3 0.118
2.5 0.098
ø2.7 ø0.106 Liner + braid tube
[stainless steel (SUS304)]
Joint bracket
[Brass (nickel plated)]
FT-H20W-M1
ø3 ø0.118 [Stainless steel (SUS)]
INDEX
7.874 +0.984
0
(100) (3.937)
ø3.8 ø0.150
2,000 78.740
Spring washer [Stainless steel (SUS)]
Cylindrical
Type
Heat-resistant side unit diagram (side view)
Beam axis ø4
ø0.157
Opposing faces7 0.276, 5.4
ø3.5 ø0.138
thickness 2.4 0.094
0.213 Lock nut (polycarbonate)
Toothed lock washer
ø2.7 ø0.106 Liner + braid tube [Stainless steel (SUS)]
ø8.5 ø0.335
Free-cut (Note)
24
A
0.945
Heat & cold-resistant Ordinary temperature
specifications
specifications
Ordinary temperature side fiber (FT-42) connection diagram (front view)
Square Head
Type
FT-H20-VJ50-S FT-H20-VJ80-S
23 0.906
A
12
Joint bracket
0.472
[Brass (nickel plated)]
Heat & cold-resistant Ordinary temperature
specifications
specifications
9.3
ø4 ø0.157 (100) (3.937) 0.366
Super
Quality
Flat
Type
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
(25)
(0.984)
ø5.5
ø0.217
1,500
59.055
2,000
78.740
500
19.685
(Allowable cutting range)
ø2.2
ø0.087
(ø4) (ø0.157) protective tube
(Fluorine resin)
51
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Thru-beam type fibers
FT-KS40
Free-cut
FT-KV26
2,000 78.740
(Set screw tightening range)
(30)
ø1 ø0.039
(1.181)
8
0.315
Beam axis
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
ø3.5 ø0.138
ø3.7
ø0.146
Holder (PC)
End bracket
[Stainless steel (SUS303)]
Free-cut
ø
ø0 4
.15
7
ø2.5
ø0.098
Holder (PC)
Assembly dimensions with MS-FD-3 (attached mounting bracket)
3
0.118
3.2 0.126
3.2 0.126
(30)
3.3
(1.181)
0.130
3.3 0.130
FT-KS40
R0.
2.5
2-R
C1 C0.039
Enclosure (LCP)
5 0.197
5 0.197
ø1
ø0.039
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Free-cut
2,000
78.740
1,500
59.055
(25)
(0.984)
500
19.685
(Allowable cutting range)
FT-R31
2,000 78.740
1.7 0.067
Enclosure [ZDC2 (Nickel plated)]
11.3 0.445
Toothed lock washer M3 [Stainless steel (SUS304)]
Hexagon nut M3 [Stainless steel (SUS304)]
1.8 0.071
ø2.3 ø0.091
(ø2) (ø0.079) Model No. tube (m-PPE)
3.8
0.150
(30)
(1.181)
ø6.5 5.5
ø0.256 0.217
ø1 ø0.039
FT-R40
Free-cut
Super
Quality
Threaded
Type
Square Head
Type
Flat
Type
Small
Spot
Sheath ø1 ø0.039 (Polyethylene)
FT-R41W
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
FT-KV25
2.1 0.083
Fibers
Wide
Beam
3.5 0.138
M3 × 0.5 0.020
Earlier models
comparison
table
Narrow
Beam
Cap [Stainless steel (SUS304-CSP)]
8
0.315
How to read
Model No.
Sleeve
Free-cut
Complete thread 10.8 0.425 or more
5.5
0.217
3.7
0.146
Choose
by shape/
application
Cylindrical
Type
ø2.2
ø0.087
(ø4) (ø0.157) protective tube
(Fluorine resin)
ø5.5
ø0.217
12.5 0.492
098
Mounting bracket
[Stainless steel (SUS304)]
ø1 ø0.039
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
R
6.5
0.256
4.7 0.185 ø2.5
ø0.098
6.5
0.256 Holder (PC)
4.1
0.161
2,000 78.740
25 0.984
10 0.394
(30)
(1.181)
FT-L80Y
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Enclosure
(LCP)
2,000 78.740
End bracket
[Stainless steel
(SUS303)]
2 0.079
ø1
ø0.039
(30)
(1.181)
3 0.118
Prism (PC)
4-C0.15 C0.006
2,000 78.740
25 0.984
Prism (PC)
(0.5) (0.020)
Prism (PC)
Fiber
Selection
Guide
Model
Mounting reference surface
20 0.787
18 0.709
39
ø1 0.0
ø
Beam axis
1.7
0.067
FT-KV40, FT-KV40W
3.7
0.146
1.5 1.3
0.059 0.051
Tough
Fiber
Free-cut
20 0.787
New product
introduction
Free-cut
Vacuumresistant
Liquid Leak /
Liquid Detection
2,000 78.740
ø1.2 ø0.047 Stainless pipe
[Stainless steel (SUS304)]
2.4
0.094
25
0.984
20
0.787
ø2.7 ø0.106
(30)
(1.181)
5°
90
°±
97
.1 9
R0 .03
R5 1 ±0
±
1 0.039
3 0.118
9
0.354
Enclosure
[Zinc die-cast (ZDC2)]
7 0.276
5 0.197
12 0.472
ø2.2
ø0.087
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
(ø3.2) (ø0.126) Model No. tube (m-PPE)
Fixing bracket [Stainless steel (SUS303)]
Toothed lock washer M4 [Stainless steel (SUS304)]
Hexagon nut M4
[Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
ø2 ø0.079
-0.004
ø4 ø0.157 -0.1
-0.13 -0.005
Mounting reference surface
(Screw periphery)
4.4 0.173
1 0.039
9.5 0.374
8 0.315
2.4 0.094
M4 × 0.7 0.028
7 0.276
ø8.5 ø0.335
3.2 0.126
Fiber
Options
2,000 78.740
6 0.236
(30)
(1.181)
(ø3.2) (ø0.126) Model No. tube (m-PPE)
Toothed lock washer M4 [Stainless steel (SUS304)]
Hexagon nut M4
[Stainless steel (SUS304)]
ø2.2 ø0.087
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
M4 × 0.7 0.028
Retroreflective
Type
7 0.276
Reflective
Type
3.2 0.126
FT-R42W
Free-cut
FT-R43
Free-cut
8 0.315
2.4 0.094
M4 × 0.7 0.028
Enclosure
FT-KV40W
[Zinc die-cast
(ZDC2)]
6
0.236
4.4 0.173
1 0.039
10 0.394
0.5 0.020
Lens
(PMMA)
ø8.5 ø0.335
3.2 0.126
9
0.354
Complete thread 6.5 0.256 or more
7
0.276
5.2
0.205
2.4 0.094
3.5 0.138
2,000 78.740
(30)
(1.181)
Cap [Stainless steel (SUS304-CSP)]
9
0.354
2
0.079
2,000 78.740
(ø3.2) (ø0.126) Model No. tube (m-PPE)
7 0.276
ø2.2 ø0.087
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
Enclosure [ZDC2 (Nickel plated)]
M4 × 0.7 0.028
3 0.118
M2.6 × 0.45 0.018
ø8.5 ø0.335
Toothed lock washer M4 [Stainless steel (SUS304)]
1 0.039
ø2 ø0.079
1.8 ± 0.1
0.071 ± 0.004
Amplifiers
(30)
(1.181)
7 0.276
(ø3.2) (ø0.126) Model No. tube (m-PPE)
Toothed lock washer M4 [Stainless steel (SUS304)]
Hexagon nut M4
[Stainless steel (SUS304)]
Others
7
0.276
Fiber
Dimensions
Thru-beam
Type
M2.6 × 0.45 0.018
ø8.5 ø0.335
Semi-custom
fibers
FX-500
series
FX-100
series
Hexagon nut M4 [Stainless steel (SUS304)]
FT-R41W
4.2 0.165
ø2.2 ø0.087
INDEX
7 0.276
3
0.118
ø1 ø0.039 fiber core × 1 (Acrylic)
Sheath ø2.2 ø0.087 (Polyethylene)
52
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Thru-beam type fibers
FT-R44Y
Free-cut
FT-R60Y
Free-cut
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Cap [stainless steel (SUS304-CSP)]
6 mm 0.236 in or more
(complete thread)
9.5
0.374
3.5
0.138
7
0.276
Toothed lock washer M4
[stainless steel (SUS304)]
3 0.118
Fibers
M4 × 0.7 0.028
M2.6 × 0.45 0.018
7
ø8.5 ø0.335 0.276
Sleeve
Flat
Type
Wide
Beam
Chemical / Oilresistant
3
Set screw
tightening range 0.118
19.5 0.768
(30)
(1.181)
Resin plug (PA)
(ø1.5) (ø0.059) Model No. tube (m-PPE)
FT-S21
Free-cut
ø1
ø0.039
(19.7)
(0.776)
10.2
0.402
(0.3)
(0.012)
ø1
(ø4.33)(ø0.170)
ø2.2 ø1.8
ø0.039
ø0.087 ø0.071
(ø2) (ø0.079) Model No. tube (m-PPE)
ø1.5 ø0.059 -0.07 -0.003
-0.10 -0.004
Mounting reference surface (Periphery)
End bracket [Stainless steel (SUS303)]
FT-S21W
Free-cut
2
0.079
8
0.315
8
0.315
2 0.079
2,000
78.740
3 0.118 (Set screw tightening range) ø1
ø0.039
(30)
3 0.118
2,000 78.740
(Set screw tightening range)
(30) (1.181)
ø1 ø0.039
(1.181)
ø1 ø0.039
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 Fiber core × 1 (Acrylic)
Sheath ø1.0 ø0.039 (Polyethylene)
End bracket [Stainless steel (SUS303)]
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
End bracket [Stainless steel (SUS303)]
-0.003
ø1.5 ø0.059 -0.07
-0.1 -0.004
Mounting reference surface
(Screw periphery)
FT-S31W
FT-S30
Free-cut
2
0.079
Set screw
5
tightening range 0.197
8
0.315
ø2
ø0.079
Thru-beam
Type
Reflective
Type
2,000
78.740
Resin plug (ABS)
(20)
(0.787)
ø1.5 ø0.591 -0.07 -0.003
-0.1 -0.004
Mounting reference surface (Periphery)
Retroreflective
Type
8
0.315
ø1
ø0.039
ø2.2 ø0.087
(ø4.33) (ø0.170)
ø1 ø0.039
Liquid Leak /
Liquid Detection
Fiber
Dimensions
2
0.079
Set screw
3
tightening range 0.118
10
0.394
End bracket [Stainless steel(SUS303)]
ø0.25 ø0.010 fiber core × 1 (PMMA)
Sheath ø0.7 ø0.028 (Polyethylene)
Vacuumresistant
Semi-custom
fibers
ø11 ø0.433 10
0.394
500 19.685
6
0.236
Heatresistant
Fiber
Options
Hexagon nut M6 [stainless steel (SUS304)]
Cover [PFA (Fluorine resin)]
Convergent
Reflective
Type
Retroreflective
Type
M6 × P0.75
FT-S20
FT-S11
Small
Spot
Narrow
Beam
Hexagon nut M4 [stainless steel (SUS304)]
ø1.0 ø0.039 fiber core × 1 (PMMA)
Outer sheath ø2.2 ø0.087 [PFA (Fluorine resin)]
Inner sheath ø1.8 ø0.071 (Polyethylene)
Threaded
Type
Cylindrical
Type
ø2.2 ø0.087
Head [stainless steel (SUS304)]
Toothed lock washer M6
[stainless steel (SUS304)]
14
0.551
(1.7 0.067)
Super
Quality
Square Head
Type
2,000 78.740
5.5
0.217
ø2.2 ø0.087
Head [stainless steel (SUS304)]
7 0.276
1 0.039
1.8±0.1
0.071±0.004
ø2 ø0.079
Cap [stainless steel (SUS304-CSP)]
11
0.433
5
0.197
10
0.394
5.5
0.217
2.4 0.094
12.5 mm 0.492 in or more
(complete thread)
2,000 78.740
2,000
78.740
Resin plug (ABS)
(20)
(0.787)
2 0.079
(19.7)
(0.776)
10.2
0.402
(0.3)
(0.012)
(ø4.33)(ø0.170) ø2.2 ø1.8
ø2.2
ø0.087
ø0.087 ø0.071
(ø3.2) (ø0.126) Model No. tube (m-PPE)
ø3 ø0.118 -0.07 -0.003
-0.10 -0.004
Mounting reference surface (Periphery)
End bracket [Stainless steel (SUS303)]
8
2,000 78.740
0.315
(Set screw tightening range)
5
ø2.2 ø0.087
0.197
(30)(1.181)
(ø3.2) (ø0.126) Model No. tube (m-PPE)
-0.003
ø3 ø0.118 -0.07
-0.1 -0.004
Mounting reference surface
(Periphery)
ø2 ø0.079
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
End bracket [Stainless steel (SUS303)]
Others
FT-S32
Free-cut
FT-V23
Free-cut
FX-500
series
FX-100
series
INDEX
FT-S11
Screw tightening range
(excluding crimping part)
ø2 ø0.079
Lens (PMMA)
ø2.5 ø0.098
End bracket [Stainless steel (SUS303)]
Crimping part
8
0.315
1.8 0.071
2,000 78.740
2 0.079
(30)
(1.181)
ø2.2
ø0.087
(ø3.2)(ø0.126) Model No. tube (m-PPE)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
View A
1.1 0.043
ø
ø0 0.8
.0
31
Amplifiers
10
0.394
Set screw tightening range
Beam axis
20 0.787
ø1
ø0.039
A
15 0.591
ø2 ø0.079
Sleeve [Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
2,000 78.740
(30)
ø1.3 ø0.051
(1.181)
(ø2.5) (ø0.098) Model No. tube (m-PPE)
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
53
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Thru-beam type fibers
FT-V24W
Free-cut
FT-V25
Set screw tightening range
10
0.394
1.8 0.071
1
0.039 2
0.02
55 ø
ø0.
10
0.394
1.8 0.071
1 0.039
(30)
(1.181)
ø2 ø0.079
15 0.591
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
ø1
ø0.039
Sleeve
[Stainless steel (SUS304)]
Fiber
Selection
Guide
Model
2,000 78.740
(30)
ø1 ø0.039
(1.181)
15 0.591
ø2 ø0.079
A
ø1 ø0.039
(ø2) (ø0.079) Model No. tube (m-PPE)
Sleeve [Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
Set screw tightening range
Beam axis
ø
ø0 0.5
.0 5
22
2,000 78.740
15 0.591
15 0.591
ø1
A ø0.039
View A
Beam axis
Tough
Fiber
Free-cut
View A
New product
introduction
(ø2) (ø0.079) Model No. tube (m-PPE)
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
End bracket [Stainless steel (SUS303)]
Fibers
FT-V30
Free-cut
FT-V40
Free-cut
10 Set screw tightening range
0.394
2.3 0.091
43
.0
.1
ø0
57
View A
ø
ø0 4
.1
1.3
0.051
2,000 78.740
15 0.591
20 0.787
FT-V24W
ø1.5
ø0.059
A
(30)
(1.181)
ø2.5
ø0.098
End bracket [Stainless steel (SUS303)]
Prism
(PC)
ø2.2 ø0.087
(ø3.2) (ø0.126) Model No. tube(m-PPE)
Sleeve [Stainless steel (SUS304)]
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
FT-V80Y
25 0.984
3.7 0.146
3 0.118
(8) (0.315)
Beam axis
ø1
Free-cut
12
0.472
ø2.5
ø0.098
FT-V25
2,000 78.740
(Set screw tightening range)
(30)
(1.181)
(ø3.2) (ø0.126) Model No. tube (m-PPE)
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
End bracket [Stainless steel (SUS303)]
Window name plate (Polyester)
Holder (PC)
1,500
59.055
(25)
(0.984)
4.5
0.177
500
19.685
(Allowable cutting range)
FT-Z20HBW
Free-cut
2 0.079
1.05 0.041
ø5.5
ø0.217
Sensing part
Beam axis mark
ø1.5
ø0.059
(30)
(1.181)
Beam axis
FT-Z20W
Free-cut
0.5
0.020
5 0.197
10 0.394
7
0.276
ø1.5 Prism
ø0.059 (PMMA)
Beam axis
FT-Z30
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Enclosure (PC)
Beam axis
0.5
3 0.118 0.020
1.75
0.069
8.5
3.9 0.154
0.335
(ø2.5) (ø0.098) Model No. tube (m-PPE)
FT-Z20HBW
11 0.433
0.5 0.020
7.5
2-ø2.2 ø0.087 hole
0.295
ø1.3
(30)
ø0.051
(1.181)
5.5
0.217
2.2 0.087
12
Reflector (PC)
0.472
(ø2.5) (ø0.098)
4.3 0.169
2,000 78.740
Center of beam axis
FT-Z30E
Free-cut
12
0.472
3.4
11
0.433 0.134
3 0.118
8 0.315
3.5 0.138
Beam
axis 2 0.079
Reflector (PMMA) 1.75 0.069
Lens (PMMA)
2,000 78.740
(30) (1.181)
ø1.3
ø0.051
(ø2.5)
(ø0.098)
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
2-ø2.2 ø0.087 hole
5.5
0.217
7.5
0.295
Small
Spot
Wide
Beam
Convergent
Reflective
Type
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Free-cut
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Flat
Type
Fiber
Options
ø2.2 ø0.087 hole, ø3.6 ø0.142
spot facing, 1.4 0.055 deep
4-R1 R0.039
ø1 ø0.039
(30) (1.181)
(ø2) (ø0.079)
Model No. tube (m-PPE)
Inner pipe [Stainless steel (SUS304)]
Enclosure (PC)
1.05 0.041
Sleeve
Chemical / Oilresistant
ø1
ø0.039
1,000 39.370
Cylindrical
Type
0.6 0.024
3.5 0.138
FT-V30
1.2
0.047
2 2.5
0.079 0.098
Square Head
Type
Retroreflective
Type
1,000 39.370
4-R1 R0.039
Enclosure (PC)
10 0.394 2.5
(ø2.0) (ø0.079) Model No. tube (m-PPE)
0.098
Inner pipe [Stainless
steel (SUS304)]
1
ø0.5 ø0.020 fiber core × 1 (PMMA)
7 0.039 2.1 Sheath ø1 ø0.039 (Polyethylene)
0.083
0.276
5 0.197
ø2.2
ø0.087
(ø4) (ø0.157) protective tube
(Fluorine resin)
10
0.394 3.5
0.138
ø2.2 ø0.087 hole, ø3.6 ø0.142
spot facing, 1.4 0.055 deep
0.5
0.020
Threaded
Type
Narrow
Beam
2,000
78.740
ø2.2
ø0.087
Super
Quality
12
Reflector (PC) 0.472
5.5
2.2 0.087 0.217
8.5
0.335
3.9 0.154
1.75
3
0.069
0.118 0.5
0.020
7.5
0.295
2,000 78.740
2-ø2.2 ø0.087 hole
ø1.3
(30)
ø0.051
(1.181)
(ø2.5) (ø0.098)
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
0.5 0.020
4.3
0.169
11
0.433
Beam axis Enclosure (PC)
(ø2.5) (ø0.098) Model No. tube (m-PPE)
(ø2.5) (ø0.098) Model No. tube (m-PPE)
FT-V40
Enclosure (PC)
FT-Z30
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
54
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
DIMENSIONS (Unit: mm in)
Earlier models
comparison
table
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Thru-beam type fibers
FT-Z30EW
Free-cut
FT-Z30H
Free-cut
3 0.118
Choose
by shape/
application
How to read
Model No
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
12
2-ø2.2 ø0.087 0.472 3.4
11
hole
0.433 0.134
8 0.315 3.5 0.138
2,000 78.740
(30) (1.181)
ø1.3
ø0.051
3 0.118
Reflector
(PMMA) 1.75 0.069
8 0.315
2,000 78.740
(30) (1.181)
ø1.3
ø0.051
(ø2.5)
(ø0.098)
3.5 0.138
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
5.5
2 0.079 0.217
7.5
1.75
0.295
0.069
Lens (PMMA)
2-ø2.2 ø0.087 hole
Enclosure (PC)
Enclosure (PC)
Lens (PMMA)
12
0.472
3.4
11
0.433 0.134
Beam
axis
(ø2.5)
(ø0.098)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Beam axis
5.5 0.217
7.5 0.295 (ø2.5) (ø0.098) Model No. tube (m-PPE)
2 0.079
(ø2.5) (ø0.098) Model No. tube (m-PPE)
Fibers
Super
Quality
FT-Z30HW
Free-cut
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
12
0.472
2,000 78.740
(30)
3.4
(1.181)
11
0.134
0.433
(ø2.5)(ø0.098) ø1.3 ø0.051
3 0.118
8 0.315 Beam 3.5 0.138
axis
Lens
(PMMA)
2 0.079 5.5
0.217
1.75 0.069
Semi-custom
fibers
ø3.2 ø0.126 hole, ø5.6 ø0.220
11
2,000 78.740
spot facing, 2.2 0.087 deep
0.433 3.5
0.138 4-R1 R0.039
1 0.039
3.5 0.138
Enclosure (PC)
1.05 0.041
(30)
ø1.3 ø0.051
3.5 0.138
(1.181)
7
14
0.276
0.551
(ø2.5) (ø0.098) Model No. tube (m-PPE)
1.6
Inner pipe [Stainless steel(SUS304)]
0.063
7
2.7 0.106
ø2.4 ø0.094
0.276
Beam
axis
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
3 0.118
7
0.276
Free-cut
7 0.276
ø2.4
ø0.094
14
0.551
Prism
(PMMA)
Beam axis
0.5
0.020 (30) (1.181)
4.3
0.169 (ø2.5)
(ø0.098)
ø1.3
ø0.051
3.9 0.154
2-ø2.2 ø0.087 hole
Reflector (PC) 2.2 0.087
FT-Z30H
Center of
beam axis
Reflector (PC)
2.2 0.087
8.5 0.335
5.5
0.217
12
0.472
12
0.472
5.5
0.217
2,000 78.740
2,000 78.740
2-ø2.2 ø0.087 hole
(30)
(1.181)
3.9 0.154
(ø2.5) (ø0.098)
4.3
0.169
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
0.5 0.020
7.5
0.295
11
0.433
Enclosure (PC) Beam axis
1.75 0.069
0.5 0.020
3 0.118
ø1.3
ø0.051
(ø2.5) (ø0.098) Model No. tube (m-PPE)
ø1 ø0.039 fiber core × 1 (PMMA)
0.6 Sheath ø1.3 ø0.051 (Polyethylene)
0.024
FT-Z40W
1
0.039
(ø2.5) (ø0.098) Model No. tube (m-PPE)
Beam axis
11
0.433
0.5 0.020
7.5
1.75 0.069
0.295
(ø2.5) (ø0.098) Model No. tube (m-PPE)
Free-cut
3.5 0.138
1.2 0.047
3.5
0.138
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Enclosure (PC)
2-ø2.2 ø0.087 hole
7.5 0.295
FT-Z40HBW
3.5 0.138
Fiber
Dimensions
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Enclosure (PC)
Liquid Leak /
Liquid Detection
Fiber
Options
Free-cut
8.5 0.335
Small
Spot
Narrow
Beam
FT-Z30W
2,000 78.740
ø3.2 ø0.126 hole, ø5.6 ø0.220
spot facing, 2.2 0.078 deep
4-R1 R0.039
(30) (1.181)
ø1.3
ø0.051
(ø2.5) (ø0.098) Model No. tube (m-PPE)
Inner pipe [Stainless steel (SUS304)]
Enclosure (PC)
1.05 0.041
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
FT-Z802Y
Free-cut
4
0.157
3
0.118 2-ø3.2 ø0.126
(7.3) (0.287)
13 0.512
FT-Z30W
(1)
(0.039)
2,000
78.740
(5.8)
(0.228)
15
0.591
7.5
0.295
6
0.236
7 0.276
Beam axis
ø2.2
ø0.087
55
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Retroreflective type fibers
FR-KZ22E
Free-cut
Reflector
15.8 0.622
14.7 0.579
0.7 0.028
1.45 0.057
FR-KZ50E
Fiber
2-M1.4 × 0.3 0.012
5.2 0.205
Prism
(PC)
Base (ABS)
Enclosure (ABS)
Reflector (PMMA)
11.2
0.441
2,000 78.740
(30)
2-ø1 ø0.039
(1.181)
(3.7)
(0.146)
(ø2) (ø0.079) Model No. tube (m-PPE)
Mounting bracket [Stainless steel (SUS303)]
11 9
7.5
0.433 0.354
0.295
2.2 0.087
25 0.984
3 0.118
3.7 0.146
9.5 0.374
Tough
Fiber
Free-cut
1.95 0.077
5
0.197
New product
introduction
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Beam axis
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fiber
Beam axis
1
0.039
2 0.079
(30)
(1.181)
Prism (PC) 1.5
0.059
2 0.079
5
0.197
9
4
0.157 0.354
Assembly dimensions with MS-FD-2 (attached mounting bracket)
9.5
0.374
21 0.827
3.7 0.146
2,000 78.740
(30)
2-ø1 ø0.039
(1.181)
(3.7)
(0.146)
Beam axis
10.2
0.402 4 0.157
5 0.197
3.3
0.130
1.2 0.047
4
0.157
14 0.551
7
0.276
Beam
axis
9.5
0.374
12.2 3.7 0.146
0.480
Sleeve
Cylindrical
Type
Flat
Type
(Accessory for FR-KZ50E)
10.1
0.398
19
28
1.102 0.748
10 0.394
(Effective reflector width)
10 0.394
(Effective reflector width)
(2-R)
Reflector
(Norbornene resin)
1 0.039
Cover [Stainless steel
(SUS304)]
3.2
0.126
10.2
0.402
3.3
0.130
Beam
axis
4
0.157
14
0.551
7
0.276
2-M3 × 0.5 0.020
MS-FD-2 Mounting bracket
[Stainless steel (SUS304)]
FR-Z50HW
Fiber
1 0.039
15
0.591
2,000 78.740
Enclosure(ABS)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Enclosure(PC)
(Accessory for FR-KZ50H)
5 0.197
1.1 0.043
5.2
0.205
Beam axis
FR-KZ50E
10.6
0.417
10 0.394
(Effective reflector width)
10 0.394
(Effective reflector width)
(2-R)
Reflector
(Norbornene resin)
Cover [Stainless steel
(SUS304)]
3.2
0.126
1
0.039
4.3
0.169
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
1 0.039
2,000 78.740
15 0.591
2-M3 × 0.5 0.020
Lens (BK7)
9.5
0.374
12.2
0.480
5 0.197
10.2
0.402 4 0.157
Heatresistant
Vacuumresistant
Fiber
Options
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
3.3 0.130
MS-FD-2 Mounting bracket
[Stainless steel (SUS304)]
3.3 0.130
1.2 0.047
6
0.236
Beam axis
14 0.551
7 0.276
4 0.157
2-ø2.2
ø0.087
Enclosure (PC)
5.2
0.205
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
Reflective tape RF-13
(Accessory for FR-Z50HW)
0.5 0.020
FR-Z50W
Rear surface
(pressure-sensitive adhesive)
Amplifiers
FX-500
series
FX-100
series
30 1.181
30
1.181
Reflective surface (Acrylic)
FR-KZ50H
Chemical / Oilresistant
2-ø2.2 ø0.087
Assembly dimensions with MS-FD-2 (attached mounting bracket)
4.6 0.181
28
19
1.102 0.748
Retroreflective
Type
Semi-custom
fibers
4.6 0.181 9.5 0.374
10.1
0.398
(2-R)
Free-cut
Lens (BK7)
5.2
0.205
Reflector RF-003
Convergent
Reflective
Type
3.3 0.130
4 0.157
1.2 0.047
6FR-KZ22E
0.236
Narrow
Beam
Liquid Leak /
Liquid Detection
4.3 0.169
(ø2) (ø0.079) Model No. tube (m-PPE)
5 0.197
Small
Spot
Wide
Beam
10.6
0.417
5 0.197
1.1 0.043
Assembly dimensions with MS-FD-2 (attached mounting bracket)
(3.7)
(0.146)
2-M3 × 0.5 0.020
MS-FD-2 Mounting bracket
[Stainless steel (SUS304)]
Enclosure(ABS)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
2,000 78.740
(30)
2-ø1 ø0.039
(1.181)
Threaded
Type
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Reflector RF-003
Super
Quality
Square Head
Type
Prism (PC)
(2-R)
21 0.827
2-ø1 ø0.039
Fibers
3.3 0.130
5.2
0.205
(ø2) (ø0.079) Model No. tube (m-PPE)
Enclosure (ABS)
(30)
(1.181)
(ø2) (ø0.079) Model No. tube (m-PPE)
5.2 0.205
(3.7)
(0.146)
12.2 3.7 0.146
0.480
Free-cut
Fiber
2,000 78.740
25 0.984
3 0.118
6
0.236
FR-KZ50H
9.5
0.374
2-ø1
ø0.039
Beam-receiving
side (Black)
Beam-emitting
2 0.079 4
side (Gray)
0.157
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Head block [Stainless steel (SUS303)]
2-M1.4 × 0.3 0.012
4 0.157
1.9
0.075
0.7 0.028
2
0.079
2,000 78.740
21.5 0.846
7.5
.039
0.295
) ø0
1.5 (2-ø1
0.059
2 0.079
INDEX
56
Tough
Fiber
Fiber
Selection
Guide
FD-30
Fibers
Super
Quality
FD-31
2
ø6.5 0.079
ø0.256 2.7
0.106 ø2
ø0.079
Choose
by shape/
application
Earlier models
comparison
table
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
Model
How to read
Model No
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
New product
introduction
10
0.394
ø3 ø0.118 -0.10 -0.004
-0.13 -0.005
Mounting reference surface (Screw periphery)
End bracket [Stainless steel (SUS303)]
Opposing faces 5.5 0.217
thickness 1.8 0.071 [Stainless steel (SUS)]
Free-cut
2,000
78.740
Resin plug(ABS)
1.8
0.071
(20)
(0.787)
ø6.5
ø0.256
(19.7)
(0.776) 10.2
0.402
ø1
M3 × 0.5
ø0.039 (ø4.33)
0.020
(ø0.170)
Toothed lock washer M3
[Stainless steel (SUS)]
(0.3)
(0.012)
ø2.2 ø1.8
ø0.087 ø0.071
(ø2) (ø0.079) Model No. tube (m-PPE)
2
0.079
2.7
0.106
Free-cut
Square Head
Type
2 0.079
10
0.394
2.7
0.106
Cylindrical
Type
1.8 0.071
ø2
End bracket ø0.079
[Stainless steel (SUS303)]
Flat
Type
(ø2) (ø0.079)
Model No. tube (m-PPE)
M3 × 0.5
0.020
17 0.669
12 0.472
1.2
0.047
2,000 78.740
30
1.181
1.8
0.071
ø1
ø0.039 Beam-emitting
side
(ø2) (ø0.079) Model No. tube(m-PPE) Beam-receiving
side
ø2.3
ø0.091
Details of
M3 × 0.5
sensing part 0.020
2.8 0.110
ø3 ø0.118
Sheath ø1.3 ø0.051 ø1.3 ø0.051
(Polyethylene)
End bracket
[Stainless steel (SUS303)] Sheath ø1 ø0.039 (Polyethylene)
Hexagon nut M3
[Stainless steel (SUS304)]
Toothed lock washer M3 [Stainless steel (SUS304)]
Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)
Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA)
FD-32GX
Free-cut
FD-40
Convergent
Reflective
Type
18 0.709
12 0.472
1.2
0.047
ø4.5
ø0.177
ø2.3 ø0.091
Retroreflective
Type
Liquid Leak /
Liquid Detection
Free-cut
Narrow
Beam
Vacuumresistant
M3 × 0.5 0.020
Toothed lock washer M3 [Stainless steel (SUS304)]
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
Toothed lock washer M3 [Stainless steel (SUS304)]
Hexagon nut M3
[Stainless steel (SUS304)]
Small
Spot
Heatresistant
ø0.5 ø0.020 Fiber core × 1 (Acrylic)
Sheath ø1 ø0.039 (Polyethylene)
FD-32G
ø6.5
ø0.256
5.5
0.217
2,000 78.740
(30)
(1.181)
2-ø1 ø0.039
Sleeve
Chemical / Oilresistant
(ø2) (ø0.079) Model No. tube (m-PPE)
ø3 ø0.118 -0.1 -0.004
-0.13 -0.005
Mounting reference surface (Screw periphery)
End bracket [Stainless steel (SUS303)]
ø6.5
ø0.256
5.5
0.217
ø1
ø0.039
(30)
(1.181)
1.8
0.071
ø2
ø0.079
Opposing faces 5.5 0.217
thickness 1.8 0.071 [Stainless steel (SUS304)]
FD-31W
Threaded
Type
Wide
Beam
2,000
78.740
10
0.394
ø6.5
ø0.256
5.5
0.217
(2.5)
(0.098)
ø3.8
ø0.150
1,000 39.370
300 11.811
6
0.236
(2.5)
(0.098)
(30)
(1.181)
700 27.559
(Allowable cutting range)
ø4.5 ø1
Beam-emitting
ø0.177 ø0.039
side
ø1.3
ø0.051
M3 × 0.5 0.020
End bracket
[Stainless steel
(SUS303)]
Toothed lock washer
M3[Stainless steel
(SUS304)]
Crimping
part
FD-31W
(ø5.1) (ø0.201)
Model No. tube (m-PPE)
Crimping
part
Beam-receiving
side
Sheath ø1 ø0.039
(Polyethylene)
Sheath ø1.3 ø0.051
(Polyethylene)
Intermediate fixing bracket
[Stainless steel (SUS303)]
Hexagon nut M3
[Stainless steel (SUS304)]
2
2,000
78.740
Resin plug(ABS)
2.4
(20)
0.094
(0.787)
12
0.472
ø8.5 0.079
ø0.335 3.5
0.138
ø2.5
ø0.098
ø4 ø0.157 -0.10 -0.004
-0.13 -0.005
Mounting reference surface (Screw periphery)
End bracket [Brass (Nickel plated)]
Opposing faces 7 0.276
thickness 2.4 0.094 [Brass (Nickel plated)]
M4 × 0.7
0.028
(19.7)
(0.776) 10.2
0.402
(0.3)
(0.012)
ø2.2 ø1.8
ø1
ø0.087 ø0.071
ø0.039 (ø4.33)
(ø0.170) (ø2) (ø0.079) Model No. tube (m-PPE)
Toothed lock washer M4 [Brass (Nickel plated)]
Protective tube
(Polyolefin tube included SUS304 spiral tube)
Details of sensing part
Fiber
Options
Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)
Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA)
Semi-custom
fibers
FD-41
ø8.5
ø0.335
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
INDEX
2
0.079
3.5
0.138
12
0.472
ø2.5
ø0.098
2,000
78.740
2.4
0.094
(30)
(1.181)
ø1
ø0.039
(ø2) (ø0.079) Model No. tube (m-PPE)
-0.1 -0.004
ø4 ø0.157-0.13
-0.005
Mounting reference surface (Screw periphery)
End backet [Stainless steel (SUS303)]
Opposing faces 7 0.276
thickness 2.4 0.094 [Stainless steel (SUS304)]
Toothed lock washer M4
[Stainless steel (SUS304)]
FD-32GX
ø0.5 ø0.020 Fiber core × 1 (Acrylic)
Sheath ø1 ø0.039 (Polyethylene)
M4 × 0.7 0.028
FD-41SW
FD-41S
Free-cut
Free-cut
ø8.5
ø0.335
7 0.276
3.5
10
0.138 0.394
40 1.575
12 0.472
5
Allowable
10 0.197
bending
0.394
range
ø2.5
ø0.098
M4 × 0.7
0.028
Toothed lock washer M4 [Stainless steel (SUS304)]
Hexagon nut M4 [Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
FD-32G
ø1.48
ø0.058 Sleeve [Stainless
steel (SUS304)]
2,000 78.740
2-ø1
(30)
ø0.039
2.4
0.094 (1.181)
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
FD-41W
Free-cut
FX-500
series
FX-100
series
Free-cut
3.5
0.138
ø8.5
ø0.335
7
0.276
40 1.575
10
0.394
Allowable
bending
range
5
0.197
12 0.472
10
0.394
ø1.48
ø2.5 ø0.098
ø0.058
Sleeve [Stainless steel
M4 × 0.7 0.028
(SUS304)]
Toothed lock washer M4 [Stainless steel (SUS304)]
Hexagon nut M4 [Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
2.4
0.094
2,000 78.740
2-ø1
(30)
ø0.039
(1.181)
(ø2) (ø0.079)
Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
ø8.5
ø0.335
2 0.079
7 0.276
3.5 0.138
12 0.472
2.4 0.094
2,000 78.740
(30)
(1.181)
2-ø1.3 ø0.051
ø3 ø0.118
End bracket [Stainless steel (SUS303)]
Toothed lock washer M4 [Stainless steel (SUS304)]
Hexagon nut M4
[Stainless steel (SUS304)]
M4 × 0.7
0.028
(ø2.5) (ø0.098) Model No. tube (m-PPE)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
57
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
FD-42G
Free-cut
FD-42GW
25 0.984
5 12 0.472
0.197
1.2
0.047
2,000 78.740
(30)
(1.181)
2.4
0.094
ø8.5
ø0.335
7
0.276
ø1
ø0.039
ø1.3 ø0.051
ø2.3
ø0.091
Beam-receiving
side
(ø2) (ø0.079 ) Model No. tube (m-PPE)
ø4
ø0.157
M3 × 0.5 0.020
M4 × 0.7 0.028
Beam-emitting
side
Sheath ø1 ø0.039 (Polyethylene)
Toothed lock washer M4
[Stainless steel (SUS304)]
1.2
0.047
25 0.984
5
0.197 12 0.472 2.4
0.094
ø2.3
ø0.091
M3 × 0.5 0.020
M4 × 0.7 0.028
(30)
(1.181)
3.5
0.138
Details of
sensing part
Details of
sensing part
Fiber
Selection
Guide
Model
ø1
ø0.039
Hexagon nut M4
[Stainless steel (SUS304)]
Toothed lock washer M4 [Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
Hexagon nut M4
[Stainless steel (SUS304)]
2,000 78.740
Beam-emitting
side
ø1.3 ø0.051
Beam-receiving
side
ø4
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.157
Sheath ø1 ø0.039 (Polyethylene)
Sheath ø1.3 ø0.051 (Polyethylene)
End bracket [Stainless steel (SUS303)]
Sheath ø1.3 ø0.051 (Polyethylene)
3.5
0.138
Tough
Fiber
Free-cut
ø8.5
ø0.335
7
0.276
New product
introduction
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)
Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)
Square Head
Type
Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA)
Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA)
Cylindrical
Type
Sleeve
FD-60
FD-61
Free-cut
ø11
ø0.433
15
0.591
2
0.079
5.5
0.217
2
0.079
ø4.5
ø0.177
ø6 ø0.236 -0.10 -0.004
-0.13 -0.005
Mounting reference surface (Screw periphery)
End bracket [Brass (Nickel plated)]
2,000
78.740
Resin plug (ABS)
(20)
(0.787)
ø11
ø0.433
(19.7)
(0.776)
10.2
0.402
(0.3)
(0.012)
ø2.2 ø1.8
ø2.2
(ø4.33)
ø0.087 ø0.071
M6 × 0.75 ø0.087 (ø0.170)
(ø3.2)
(ø0.126)
Model
No. tube (m-PPE)
0.030
Toothed lock washer M6 [Brass (Nickel plated)]
Opposing faces 10 0.394
thickness 2 0.079 [Brass (Nickel plated)]
FD-61G
2
0.079
Free-cut
5.5
0.217
ø4.5
ø0.177
15
0.591
2 0.079
2,000
78.740
(30)
(1.181)
ø11 ø0.433
10 0.394
15
0.591
2
0.079
(30)
(1.181)
-0.1 -0.004
ø6 ø0.236-0.13
-0.005
(ø3.2) (ø0.126) Model No. tube (m-PPE)
ø1 ø0.039 Fiber core × 1 (Acrylic)
Sheath ø2.2 ø0.087 (Polyethylene)
Mounting reference surface (Screw periphery)
End bracket [Stainless steel (SUS303)]
Opposing faces 10 0.394
thickness 2 0.079 [Stainless steel (SUS304)]
Toothed lock washer M6
[Stainless steel (SUS304)]
M6 × 0.75 0.030
2-ø2.2 ø0.087
Details of
sensing part
Sheath ø2.2 ø0.087
(Polyethylene)
Toothed lock washer M6 [Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
M6 × 0.75 0.030
5.5
0.217
Free-cut
ø11 ø0.433
10 0.394
5.5
10
0.217 0.394
Allowable 5 0.197
bending
10
0.394
range
ø2.5 ø0.098
Sleeve [Stainless steel (SUS304)]
2
0.079
ø3.5
ø0.138
M6 × 0.75 0.030
Toothed lock washer M6 [Stainless steel (SUS304)]
Hexagon nut M6 [Stainless steel (SUS304)]
2,000 78.740
2-ø2.2 ø0.087
(30)
(1.181)
(ø3.2) (ø0.126)
Model No. tube (m-PPE)
End bracket
[Stainless steel (SUS303)]
ø4.5
ø0.177
Hexagon nut M6
[Stainless steel (SUS304)]
Toothed lock washer M6
[Stainless steel (SUS304)]
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Retroreflective
Type
Reflective
Type
Free-cut
15
0.591
2
0.079
Liquid Leak /
Liquid Detection
Thru-beam
Type
FD-62
Free-cut
2
0.079
5.5 0.217
Chemical / Oilresistant
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
Beam-emitting ø1 ø0.039 fiber core × 1 (PMMA)
ø11 ø0.433
10 0.394
Retroreflective
Type
15
0.591
Beam-receiving ø0.25 ø0.010 fiber core × 16 (PMMA)
FD-61W
Wide
Beam
Vacuumresistant
FD-61S
(ø3.2) (ø0.126) Model No. tube (m-PPE)
Hexagon nut M6 [Stainless steel (SUS304)]
Narrow
Beam
Heatresistant
40 1.575
2,000 78.740
Small
Spot
Convergent
Reflective
Type
2
0.079
ø4.5
ø0.177
ø2.2
ø0.087
Flat
Type
2,000 78.740
2-ø2.2 ø0.087
(30) (1.181)
ø11 ø0.433
10 0.394
5.5 0.217
(ø3.2) (ø0.126)
Model No. tube (m-PPE)
M6 × 0.75 0.030
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
End bracket
[Stainless steel (SUS303)]
Others
-0.1 -0.004
ø6 ø0.236-0.13
-0.005
2
0.079
15
0.591
2
0.079
ø4.5
ø0.177
Hexagon nut M6
[Stainless steel (SUS304)]
Mounting reference
surface (Screw periphery) Toothed lock washer
M6 [Stainless steel (SUS304)]
2,000 78.740
2-ø2.2 ø0.087
(30) (1.181)
(ø3.2) (ø0.126) Model No. tube (m-PPE)
ø1.5 ø0.059 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
End bracket [Stainless steel (SUS303)]
M6 × 0.75 0.030
Amplifiers
FX-500
series
FX-100
series
INDEX
58
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
FD-64X
FD-A16
Protective tube
Polyolefin tube included
SUS304 spiral tube
22
0.866
2
15
0.079
10
0.591
0.394
Earlier models
comparison
table
Details of
sensing part
Square Head
Type
Cylindrical
Type
5.5
0.217
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
2-ø2.2 ø0.087
4.5 0.177 5.1 0.201
(30)
(1.181)
(ø5.1)
(ø0.201)
Resin plug (ABS)
FD-AL11
Free-cut
B
Beam-receiving side
A
Beam-emitting side
Enclosure (PC)
7 0.276
Sheath ø2.2 ø0.087 (Polyethylene)
View A
View B
Beam-emitting ø1 ø0.039 fiber core
× 1 (PMMA)
Beam-receiving ø0.25 ø0.010 fiber core
× 16 (PMMA)
FD-E13
20
0.787
13
0.512
5 0.197
2.5 0.098
Details of
sensing part
2.5
0.098
1 0.039
ø0.48 ø0.019
2-ø2.2
ø0.087
15
0.591
3
0.118
5 0.197
ø0.25 ø0.010 × 16 fiber core (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
5
0.197
2-ø2.2 ø0.087
4.5 0.177 5.1 0.201
4 0.157 (Set screw tightening range)
(30)
ø1.5 ø0.059 ø0.9 ø0.035
(1.181)
2,000 78.740
2-M3 × 0.5 0.020
20 15
0.787 0.591
Head block
(LCP)
(ø2.5) (ø0.098)
1,000 39.370
6 0.236
(1) (0.039)
10.7
0.421
(3.1) (0.122)
Enclosure (PPS)
7 11 11.6
0.276 0.433 0.457
10.85 0.427
Sleeve [Stainless steel
(SUS304)]
Details of
sensing part
Sensing part ø0.25 ø0.010 fiber core × 32
(emitter / receiver alternating line)
Resin plug (ABS)
(ø2.5) (ø0.098) Model No. tube (m-PPE)
(ø0.9) (ø0.035) Protective tube (Polyolefin)
End bracket
[Stainless steel (SUS303)]
ø0.125 ø0.005 fiber core × 2 (PMMA)
(each beam-emitting part and beam-receiving part)
FD-EG30
FD-E23
ø3 ø0.118
Semi-custom
fibers
(30)
(1.181)
2-ø2.2 ø0.087
4.5 0.177 5.1 0.201
(30)
(1.181)
Resin plug (ABS)
(ø1.6) (ø0.063) Protective tube (Polyolefin)
5 0.197
15
0.591
1,000 39.370
6 0.236
(1) (0.039)
(3.4) (0.134)
Retroreflective
Type
End bracket
[Stainless steel (SUS303)]
Reflective
Type
5.5 1.2
0.217 0.047
10.7
0.421
Beam-receiving
7 11 11.6 side
0.276 0.433 0.457 Beam-emitting
side
(ø3) (ø0.118) Model No. tube (m-PPE)
Details of
sensing part
Sleeve [Stainless steel (SUS304)]
2-ø2.2 ø0.087
4.5 0.177
5.1 0.201
(ø3)
(ø0.118) Resin plug (ABS)
(ø1.6) (ø0.063) Protective tube (Polyolefin)
(ø3)
(ø0.118)
ø0.63 ø0.025
Thru-beam
Type
Others
2,000 78.740
2-ø2.2 ø0.087
8 0.315
9 0.354
Beam axis
10.7 0.421
Liquid Leak /
Liquid Detection
Fiber
Dimensions
15
0.591
2 0.079
28 1.102
3.6 0.142
2-ø3.3 ø0.130
1,000 39.370
6 0.236
(2.5)
(0.098)
(5.8) (0.228)
2
0.079
Vacuumresistant
Fiber
Options
Lens
(Norbornene resin)
11
11.6
7
0.276 0.433 0.457
Crimping part
ø11 ø0.433
End bracket
M6 × 0.75 0.030 (ø5.1) (ø0.201) Model No. tube (m-PPE)
[Stainless steel (SUS303)]
Hexagon nut M6 [Stainless steel (SUS304)]
Toothed lock washer M6
[Stainless steel (SUS304)]
ø0.25 ø0.010 fiber core × 9 (PMMA)
(each beam-emitting part and beam-receiving part)
Sleeve
Flat
Type
ø3.8
ø0.150
ø4.5
ø4.5
ø0.177 ø0.177
How to read
Model No
Threaded
Type
Free-cut
Choose
by shape/
application
Super
Quality
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
Model
Fibers
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
16
0.630
ø6.5 ø2.3
ø0.256 ø0.091
Details of sensing part
2.8
0.110
500 19.685
6 0.236
FD-E13
10.7
(1) (0.039)
0.421
1.8 (3.6) (0.142)
0.071
Beam-receiving
7 11 11.6 side
0.276 0.433 0.457 Beam-emitting
side
(ø3) (ø0.118) Model No. tube (m-PPE)
M3 × 0.5 0.020
End bracket
[Stainless steel (SUS303)]
Hexagon nut M3
[Stainless steel (SUS304)]
Toothed lock washer M3 [Stainless steel (SUS304)]
Beam-emitting ø0.25 ø0.010 fiber core × 1 (PMMA)
Beam-receiving ø0.125 ø0.005 fiber core × 9 (PMMA)
Amplifiers
FX-500
series
FX-100
series
INDEX
Beam-receiving ø0.125 ø0.005 fiber core × 9 (PMMA)
Beam-emitting ø0.25 ø0.010 fiber core × 1 (PMMA)
59
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
FD-EG30S
FD-EG31
2-ø2.2 ø0.087
Sleeve
[Stainless steel (SUS304)]
15
0.591
15
0.591
5.5
0.217
1.8
0.071
1,000 39.370
6 0.236 10.7
(1) (0.039)
0.421
(3.6) (0.142)
Beam-receiving
7 11 11.6 side
0.433
0.457 Beam-emitting
0.276
M3 × 0.5 0.020
side
(ø3) (ø0.118) Model No. tube (m-PPE)
Hexagon nut M3
[Stainless steel (SUS304)]
Toothed lock washer M3 [Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
ø6.5
ø0.256
Details of sensing part
2.7 0.106
(ø2.5)
(ø0.098) Resin plug (ABS)
(ø1.2) (ø0.047) Protective tube (Polyolefin)
16
500 19.685
0.630
6 0.236
5.5
(1) (0.039)
1.3 0.051 1.8
10.7
0.217
0.421
0.071 (3.1) (0.122)
Beam-receiving
7 11 11.6 side
0.276 0.433 0.457 Beam-emitting
M3 × 0.5 0.020
side
ø6.5 ø0.256
(ø2.5) (ø0.098) Model No. tube (m-PPE)
End bracket [Stainless steel (SUS303)]
Details of sensing part
2.8 0.110
Hexagon nut M3
[Stainless steel (SUS304)]
Toothed lock washer M3[Stainless steel (SUS304)]
Beam-receiving ø0.125 ø0.005 fiber core × 6 (PMMA)
Beam-receiving ø0.125 ø0.005 fiber core × 9 (PMMA)
FD-F4, FD-F41
Free-cut
500
19.685
2-ø3.2 ø0.126 mounting holes
5
0.197
(ø3) (ø0.118)
Model No. tube (m-PPE)
14
0.551
ø1 ø0.039 × 2
(20)
(0.787)
14
0.551
2,000
78.740
4
0.157
(4.44)
(0.175)
(1.0)
(0.039)
(ø1.15)
(ø0.045)
13
0.512
2,000
78.740
(50)
(1.969) Protective tube
Range where cutting is not possible
(17) Bending prohibited range
(0.8)
(0.669)
(0.031)
(10) Crimping part
(0.039)
ø1 ø0.039 × 2
Primary sheath: Polyethylene
Secondary sheath: [PFA (fluorine resin)]
Free-cut
5,000 196.850
3,000 118.110
30 1.181
7.8 0.307
Emission indicator
10
20 0.394
0.787
[PFA(Fluorine resin)]
Sleeve
Flat
Type
Narrow
Beam
Wide
Beam
Heatresistant
Free-cut
1,000
39.370
Vacuumresistant
Liquid Leak /
Liquid Detection
1,000
39.370
(Allowable cutting range)
(26) (1.024)
(Bending prohibited range)
16
8
0.315 0.630
Beam-emitting side
(Gray)
Beam-receiving side
(Black)
ø0.25 ø0.010 fiber core × 4 (PMMA)
Outer sheath ø1 ø0.039 (Polyethylene)
(ø3.1) (ø0.122) Protective tube
[PFA(Fluorine resin)]
Threaded
Type
Chemical / Oilresistant
FD-F8Y
2-ø1
ø0.039
Super
Quality
Retroreflective
Type
Fiber
Fibers
Convergent
Reflective
Type
FD-EG31
FD-F71
Earlier models
comparison
table
Small
Spot
(ø4) (ø0.157) Protective tube
[PFA (fluorine resin)]
10
0.394
How to read
Model No.
Cylindrical
Type
Free-cut
20
0.787
6 0.236
13.5
25 0.531
0.984
FD-F41Y
Choose
by shape/
application
Square Head
Type
Beam-emitting ø0.125 ø0.005 fiber core × 1 (PMMA)
Beam-emitting ø0.25 ø0.010 fiber core × 1 (PMMA)
8
0.315
Model
5.1 0.201
(ø3)
(ø0.118)
Resin plug (ABS)
(ø1.6) (ø0.063) Protective tube (Polyolefin)
Tough
Fiber
Fiber
Selection
Guide
2-ø2.2 ø0.087
4.5 0.177
(30)
(1.181)
ø2.3 ø0.091
4.5 0.177 5.1 0.201
(30)
(1.181)
ø0.8 ø0.031
New product
introduction
Fiber
Options
ø2.2 ø0.087 × 2
(ø6) (ø0.236) protective tube (Fluorine resin)
10
0.394
Semi-custom
fibers
22 0.866
SUS mounting bracket
17
0.669
10
0.394
17.7 12.2 0.480
0.697
SUS mounting bracket (FD-71)
mounting diagram
6.2 0.244
Details of sensing part
15.5 10.5 0.413
0.610
17
0.669
FD-F71
Mounting holes (for tying band)
SUS mounting bracket
(9.4)
(0.370)
0.3 0.012
12
0.472
10
0.394
10
15 0.394
0.591
11.5
ø4.2 ø0.165 thru-holes
0.453
Material: [PFA(Fluorine resin)]
Material: Stainless steel (SUS316)
10.3 0.406
PVC mounting bracket
Free-cut
30 1.181
0.3
0.012
5.5 0.217
11 0.433
FD-FA93
7.8 0.307
20.3
28.3 0.799
1.114
PVC mounting bracket
(FD-71) mounting diagram
6.5 3 0.118
0.256 0.9 0.035
2.5
0.098
5.2 0.205
22.2
0.874
4 0.157
11
Welding part
0.433
Material: PVC
5.2 0.205
ø0.25 ø0.010 fiber core × 9 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
2,000
78.740
10
0.394
25
0.984
FD-F71
11.5
0.453
10 0.394
Sensing part
(emitter / receiver
alternating line)
17.1
0.673 (ø0.25 ø0.010 fiber core × 18)
Enclosure (ABS)
30 1.181
5.7
0.224
8.75
0.344
Fiber
Dimensions
PVC mounting bracket
2-ø1.3
ø0.051
3 0.118
2.5
0.098
INDEX
60
DIMENSIONS (Unit: mm in)
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
FD-H13-FM2
Free-cut
FD-H18-L31
Free-cut
Details of
sensing part
16
0.630
15
0.591
5
0.197
5.5
0.217
ø1.5 ø0.059
fiber core × 2
7
0.276
10.75
0.423
2,000
78.740
How to read
Model No
2,000
78.740
20
0.787
6.5
0.256
2.7
0.106
A
19
0.748
Screw tightening
face
Earlier models
comparison
table
ø5
ø0.197
M6 × 0.75 0.030
ø2.2 ø0.087 × 2
(Fluorine resin)
Opposing faces 10 0.394, thickness 2 0.079
Toothed lock washer ø11 ø0.433
8
0.315
4
0.157
5
0.197
Fibers
Super
Quality
2-M3 × 0.5 0.020
Head [Stainless steel (SUS)]
Holder [Stainless steel (SUS)]
View A
ø4.6
ø0.181
Threaded
Type
A
ø2.2 ø0.087 × 2
(Fluorine resin)
End bracket (Brass)
Emitter / Receiver fiber
ø1.5 ø0.059 × 1
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
FD-H20-21
FD-H20-M1
Details of
sensing part
Beam-receiving part:
ø50 µm ø1.969 mil × 440
Beam-emitting part:
ø50 µm ø1.969 mil × 440
1,000
39.370 60
35
30
2.362
1.378
ø3.1
1.181
16.7 18.3
ø10
ø0.122
0.657 0.720
ø0.394
5
0.197
ø5 ø0.197
Emitter mark
ø4
ø5
ø0.197
ø0.157
ø2.9 ø0.114
M4 × 0.7 Liner + braid tube
Joint
0.028 [Stainless steel (SUS)]
27
1.063
20
0.787
5
0.197
ø2.2
ø0.087
Beamemitting
side
Beam3.5
receiving
0.138
side
ø3 ø0.118
Toothed lock washer ø8.5 ø0.335
[Stainless steel (SUS)]
Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)]
Heatresistant
Heat & cold-resistant
Details of
specifications
sensing part
Ordinary temperature
specifications
Joint [Brass (Nickel plated)]
Beam-receiving part:
28
1,000
inside diameter ø1.1 ø0.043
1.102
39.370
25
150
60 ± 5
outside diameter ø1.6 ø0.063
18.3
16.7
5.906 0.984
2.362 ± 0.197 0.657 0.720 Beamfiber core bundle × 1
15
5
0.591
0.197
receiving
5.5
D
side
0.217
ø2.2 ø0.087
BeamP
ø9 ø0.354
Screw
emitting
ø6
ø4.2 ø0.165 (Silicone)
tightening face
side
ø0.236
Fixing
plug
(PA)
ø5
End bracket
Beam-emitting part: ø3.5
ø0.197
Fixing
bracket
ø0.138
[Brass
(Nickel
plated)]
ø1.1 ø0.043 fiber
[Brass
(Nickel
plated)]
core bundle × 1
M6 × 0.75
Opposing faces 10 0.394,
ø2.9 ø0.114 (Silicone)
0.030
thickness 2 0.079
Toothed lock washer ø11 ø0.433
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
FD-H25-L43
FD-H25-L45
33.2
1.307
21.7
0.854
5
0.197
4.5
0.177
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
3,000
118.110
34.5
1.358
23
0.906
19.5
0.768
Ordinary
temperature
specifications
(150)
(5.906)
10
0.394
BeamA emitting side
(ø4.33) (ø0.170) BeamA receiving side
ø2.2 ø0.087 × 2
21
0.827
2 0.079
ø3.8 ø0.150
Thru-beam
Type
Retroreflective
Type
6.5
0.256
Heat-resistant
specifications
ø2.9
ø0.114
5
0.197
4.5
0.177
6.5
0.256
Heat-resistant
specifications
ø2.9
ø0.114
2
0.079
Slit mask [Stainless steel (SUS)]
Beam axis
Enclosure (Heat-resistant resin)
ø5
ø0.197
(24.2)
(0.953)
View A
ø1.2 ø0.047 (Beam-receiving fiber
ø1.5 ø0.059) fiber core × 1
19.5
0.768
10
0.394
BeamA emitting side
(ø4.33) (ø0.170) BeamA receiving side
ø2.2 ø0.087 × 2
ø3.8 ø0.150
Tube [Stainless steel (SUS)]
2-mounting holes for M3 countersunk head screw
Fiber holder (Heat-resistant resin)
Ordinary
temperature
specifications
(150)
(5.906)
21
0.827
Tube [Stainless steel (SUS)]
Prism (BK7)
3,000
118.110
2-mounting holes for M3 countersunk head screw
Prism (BK7)
Slit mask [Stainless steel (SUS)]
Beam axis
Fiber holder (Heat-resistant resin)
Enclosure (Heat-resistant resin)
ø5
ø0.197
(24.2)
(0.953)
View A
ø1.2 ø0.047 (Beam-receiving fiber
ø1.5 ø0.059) fiber core × 1
Resin plug (PA)
Resin plug (PA)
Fixing bracket [Brass (Nickel plated)]
Fixing bracket [Brass (Nickel plated)]
61
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
FD-H30-KZ1V-S
FD-H30-L32
21.7
(0.854
)
15
0.591
1,000 39.370
30 1.181
11
0.433
ø4
ø0.157
Glass lens (BK7)
ø3.6
ø0.142
9.5
0.374
End bracket
[Stainless steel (SUS)]
Enclosure [Stainless steel (SUS)]
4.6 0.181
2-ø1 ø0.039 vent holes
10.75
0.423
Mounting cap nut opposing faces
8 0.315 [Stainless steel (SUS)]
Joint [Stainless steel (SUS)]
Liner + braid tube
[Stainless steel (SUS)]
12.2
0.480
10.2
0.402
9.5
0.374
4.6
0.181
t 1.2 t 0.047
6 0.236
Holder [Stainless steel (SUS)]
View A
ø4.6
ø0.181
Emitter / Receiver fiber
ø1.2 ø0.047 fiber core × 1
FD-H30-L32V-S
6.5
0.256
ø4
ø0.157
10.75
0.423
(1.2 0.047)
19
0.748
8
0.315
ø3.6
ø0.142
30 1.181
11
0.433
Details of
sensing part
4 0.157
ø4 ø0.157
4 0.157
ø4.6
ø0.181
3.4
(0.134
)
Mounting cap nut opposing faces
8 0.315 [Stainless steel (SUS)]
Wide
Beam
90
3.543
Allowable
bending range
5
0.197
27
1.063
20
0.787
10
0.394
ø4
ø0.157
ø2.1 ø0.083 [Stainless steel (SUS)]
ø3 ø0.118
1,000
39.370
35
60
1.378
30
2.362
16.7 18.3
1.181
0.657 0.720 ø2.2
5
ø0.087
0.197
ø5 ø0.197
ø2.9 ø0.114 Resin plug (PA)
ø10 ø0.394
Joint
ø3.1
ø5 ø0.197
ø0.122
M4 × 0.7 0.028 Liner + braid tube [Stainless steel (SUS)]
Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)]
Toothed lock washer ø8.5 ø0.335 [Stainless steel (SUS)]
Beam-emitting part:
ø50 µm ø1.969 mil × 380
ø2.7 ø0.106
Details of
sensing part
Heat & cold-resistant
Ordinary temperature
specifications
specifications
3
22
2,000
Beam-receiving part: 0.118
0.866
78.740
inside diameter ø1.8 ø0.071
150
30
60 ± 5
outside diameter ø2.2 ø0.087
5.906
1.181
2.362 ± 0.197
17
fiber core bundle × 1
5
0.669
0.197
ø4 ø0.157
[Stainless steel (SUS)]
M6 × 0.75 0.030
[Stainless steel (SUS)]
FD-H35-M2S6
ø1.8 ø0.071 fiber
core bundle × 1
emitting and
receiving
Beam-emitting part:
ø1.3 ø0.051 fiber
core bundle × 1
16.7
0.657
ø4 ø0.157
[Stainless steel (SUS)]
M6 × 0.75 0.030 [Stainless steel (SUS)]
Toothed lock washer
ø11 ø0.433 [Stainless steel (SUS)]
ø5
ø0.197
ø10 ø0.394
Joint [Brass
ø3 ø0.118
(Nickel plated)] (Silicone)
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Semi-custom
fibers
16.7
0.657
Beamreceiving
side
ø2.2 ø0.087
Beamemitting
side
Fixing plug (PA)
Fixing bracket
[Brass (Nickel plated)]
Opposing faces 10 0.394, thickness 2 0.079 [Stainless steel (SUS)]
Toothed lock washer ø11 ø0.433 [Stainless steel (SUS)]
ø5 ø0.197
[Stainless
steel (SUS)]
ø10
ø0.394 ø3 ø0.118
ø5 ø0.197 (Silicone)
ø3.8 ø0.150
[Stainless steel (SUS)]
FD-HF40Y
18.3
0.720
18.3
0.720
P
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Free-cut
Amplifiers
ø5 ø0.197
ø2.8 ø0.110
[Stainless steel (SUS)]
Chemical / Oilresistant
FD-H35-M2
D
ø5 ø0.197
Heat & cold-resistant Ordinary temperature
specifications
specifications
2,000
22
60
78.740
0.866
2.362
60 ± 5
30
150
2.362 ± 0.197
1.181
5.906
5
17
5
0.197
0.669
0.197
Retroreflective
Type
Fiber
Options
Note: The FD-H30-L32V-S is a set with the FD-H30-L32V, photo-terminal,
and atmospheric side fiber. Refer to p.66 for dimensions of the
atmospheric side fiber and photo-terminals.
Details of
sensing part
Cylindrical
Type
Convergent
Reflective
Type
10
Beam-receiving part: 0.394
ø50 µm ø1.969 mil × 380
End bracket
[Stainless steel (SUS)]
Liner + braid tube
2-M3 × 0.5 0.020
Enclosure [Stainless steel (SUS)] [Stainless steel (SUS)]
Holder [Stainless steel (SUS)]
Square Head
Type
Narrow
Beam
Joint [Stainless steel (SUS)]
Rod prism (BK7)
5
0.197
3,000 118.110
Super
Quality
Small
Spot
FD-H35-20S
16.7
(0.657
)
Fibers
Flat
Type
Note: The FD-H30-KZ1V-S is a set with the FD-H30-KZ1V, photo-terminal,
and atmospheric side fiber. Refer to p.66 for dimensions of the
atmospheric side fiber and photo-terminals.
20
0.787
Earlier models
comparison
table
Sleeve
Mounting bracket (MS-FD-2)
7 0.276 [Stainless steel (SUS)]
5.2
0.205
7
0.276
How to read
Model No.
Tube [Stainless steel (SUS)]
End bracket [Stainless steel (SUS)]
2-M3 × 0.5 0.020
Head [Stainless steel (SUS)]
4 0.157
3.3 0.130
14
0.551
Choose
by shape/
application
Threaded
Type
3.3 0.130
4
0.157
Model
18.3
0.720
A
ø2.2 ø0.087 × 2
Fixing plug (PA)
Fixing bracket
[Brass (Nickel plated)]
5
0.197
2-M3 × 0.5 0.020
ø4 ø0.157
Tough
Fiber
Fiber
Selection
Guide
A
4
0.157
Assembly dimensions with MS-FD-2 (attached mounting bracket)
15
0.591
2,000
78.740
16.7
0.657
16.7
6.5
0.657
0.256
ø5
ø4
ø2.9
ø0.197
ø0.157 ø0.114
8
0.315
19
0.748
ø2.7 ø0.106
5.2
0.205
20
0.787
7
0.276
4 0.157
ø4 ø0.157
New product
introduction
500
ø2.2
ø0.087
ø3.8 ø0.150
Fixing plug (PA)
[Stainless steel (SUS)]
ø5 ø0.197
Fixing bracket
[Stainless steel (SUS)]
[Brass (Nickel plated)]
Opposing faces 10 0.394,
thickness 2 0.079 [Stainless steel (SUS)]
19.685
(50)
(1.969) Protective tube
Range where cutting is not possible
(4.44)
(0.175)
(1.0)
(0.039)
(0.8)
(0.031)
(ø1.15)
(ø0.045)
2,000
78.740
(17) Bending prohibited range
(0.669)
(10) Crimping part
(0.394)
(ø4) (ø0.157) Protective tube
[PFA (fluorine resin)]
FX-500
series
ø1 ø0.039 × 2
(Polyethylene)
FX-100
series
INDEX
62
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
DIMENSIONS (Unit: mm in)
FD-L10
Free-cut
19 0.748
7 0.276
2 0.079
Lens (PMMA)
12
0.472
4.5 0.177
Slit mask [Stainless steel
(SUS304-CSP-H)]
2.5
0.8 0.031
0.098
3 0.118
12
0.472
Free-cut
7.2
0.283
7 0.276
8
0.315
FD-L20H
Free-cut
FD-L21
Free-cut
21 0.827
6.5 7
0.256 0.276
3 0.118
24
0.945
16
0.630
Heatresistant
Enclosure (ABS)
Liquid Leak /
Liquid Detection
4 0.157
2,000 78.740
2-mounting holes for M3
countersunk head screw
Enclosure (ABS)
FD-L21W
Free-cut
3 0.118
21 0.827
6.5 7
0.256 0.276
2,000 78.740
2-mounting holes for M3
countersunk head screw
16
0.630
24
0.945
Front film (Polyester)
4 0.157
Beam axis (2) (0.079)
(19) (0.748) 0.5 ø0.020 × 1 fiber øcore (Acrylic)
Sheath ø1 ø0.039 (Polyethylene)
Beam axis
Front film (Polyester)
(2) (0.079)
Free-cut
FD-L23
Free-cut
29 1.142
6.5
18 0.709
2.5 0.098 0.256
17
0.669
2,000 78.740
2-ø1.3 ø0.051
(15.3)
10 0.394 (0.602)
12
0.472
2 0.079
Enclosure (ABS)
2-mounting holes for M3
countersunk head screw
3.8 0.150
Beam axis
Thru-beam
Type
2.5
0.098
Beam-emitting
side (Gray)
29 1.142
6.5
18 0.709
0.256
18
0.709
Beam-receiving
side (Black)
2-mounting holes for M3
countersunk head screw
3.8 0.150
Beam axis
(4.88) (0.192)
ø0.25 ø0.010 fiber core × 9 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Enclosure (PC)
FD-L30A
Free-cut
2-mounting holes for M3
countersunk head screw
3.8 0.150
Beam axis
FD-L21
Enclosure (ABS)
ø0.25 ø0.010 fiber core × 9 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
3
0.118
2-ø1.3 ø0.051
ø0.25 ø0.010 fiber core × 9 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
(1.95) (0.077)
(1.8) (0.071)
Free-cut
FD-L20H
3,000 118.110
Beam-emitting
side (Gray)
(17.3) (0.681)
Beam-receiving
side (Black)
(5.3) (0.209)
20
0.787
Beam-emitting
side (Gray)
(16.3) (0.642)
Beam-receiving
(4.8) (0.189)
side (Black)
FD-L31A
29 1.142
18 0.709
6.5
2.5 0.098 0.256
3,000 118.110
2-ø1.3 ø0.051
(1.8) (0.071)
Retroreflective
Type
Amplifiers
2-ø1 ø0.039
Enclosure (ABS)
FD-L22A
Fiber
Dimensions
INDEX
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
6 0.236
2-ø1 ø0.039
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
(19) (0.748)
FD-L10
Vacuumresistant
FX-100
series
2-ø1 ø0.039
Retroreflective
Type
FX-500
series
13 0.512
Lens (PMMA)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
1.5 0.059
ø1.6 ø0.063
0.5
0.020
Convergent
Reflective
Type
Others
2,000 78.740
2.5 0.098
3 8
2-ø 0.11
ø
(ø2) (ø0.079) Model No. tube (m-PPE)
Mounting holes for M2 countersunk head screw
2-ø1 ø0.039
Beam axis
2 0.079
Small
Spot
14 0.551
1,000 39.370
2.5 0.098 (30)
(5) (0.197) (1.181)
18
0.709
Enclosure
(PC)
Prism
(PC)
Flat
Type
Reflective
Type
ø0.75 ø0.030 fiber core × 1 (PMMA)
2,000 78.740
3.5
Sheath ø1.3 ø0.051 (Polyethylene)
0.138
ø1.3 ø0.051 ø1 ø0.039
Beam-receiving side
(7) (0.276)
Beam-emitting side
ø0.5 ø0.020 × 1 fiber core (Acrylic)
Sheath ø1 ø0.039 (Polyethylene)
0.6
2.9
0.024
0.114
2-mounting holes for M3 countersunk head screw
Enclosure (PC)
3 0.118
Beam (1.15) (0.045)
axis
2-mounting holes for M3 countersunk head screw
1.5 0.059
Sleeve
Semi-custom
fibers
19
0.748
7 0.276
2 0.079
Lens (PMMA)
(1.15) (0.045)
0.5 0.020
Cylindrical
Type
Fiber
Options
Free-cut
Square Head
Type
Chemical / Oilresistant
ø0.75 ø0.030 fiber core × 1 (PMMA)
2,000 78.740
Sheath ø1.3 ø0.051 (Polyethylene)
3.5 0.138
ø1.3 ø0.051 ø1 ø0.039
Beam-receiving side
(7) (0.276)
Beam-emitting side
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
FD-L12W
Threaded
Type
Wide
Beam
FD-L11
Enclosure (PC)
Narrow
Beam
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
Fibers
Super
Quality
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
29 1.142
6.5
18 0.709
0.256
3,000 118.110
(2.1) (0.083)
Beam-emitting
side
FD-L11
23.5
0.925
2-ø2.2 ø0.087
(19.4) (0.764)
FD-L21W
2-mounting holes for M3
countersunk head screw
4.5 0.177
Beam axis
Enclosure (ABS)
Beam-receiving
side
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
ø0.25 ø0.010 fiber core × 16 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
(2.3) (0.091)
63
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
FD-L32H
Free-cut
25
0.984
(8) (0.315)
Lens (Norbornene resin)
15
0.591
15 0.591
Cap [Stainless steel (SUS304-CSP)] (ø2) (ø0.079) Model No. tube (m-PPE)
8
0.315
M3 × 0.5 0.020
2,000 78.740
Beam-emitting side
Beam-receiving side
ø1.3 ø0.051
3.5 0.138
Sheath
ø1.3 ø0.051
(Polyethylene)
11.3 0.445
12.5 0.492
Sheath
ø1 ø0.039
(Polyethylene)
Hexagon nut M3 [Stainless steel (SUS304)]
Threaded
Type
2.1 0.083
FD-R33EG
FD-R33EG outline drawing
Cap [Stainless steel
(SUS304-CSP)]
500 19.685
1.7 0.067
(ø3) (ø0.118)
Model No. tube (m-PPE)
(30)
(1.181)
(1) (0.039)
6
10.7
0.236 0.421
Protective tube
ø1.6 ø0.063 (Polyolefin)
Enclosure [ZDC2 (Nickel plated)]
Toothed lock washer M3
[Stainless steel (SUS304)]
Hexagon nut M3
[Stainless steel (SUS304)]
1.8 0.071
ø2.3
ø0.091
4.5 5.1
0.177 0.201
ø2.2
ø0.087
ø6.5 5.5
ø0.256 0.217
11.6 0.457
Cap [Stainless steel
(SUS304-CSP)]
500 19.685
1.7 0.067
(ø3) (ø0.118)
Model No. tube (m-PPE)
(1) (0.039)
6
(30)
0.236
(1.181)
7
11 0.433 0.276
FD-R41
Toothed lock washer M3 [Stainless steel (SUS304)]
Hexagon nut M3
Resin plug (ABS)
[Stainless steel (SUS304)]
Beam3.8 0.150
receiving
side
ø6.5 5.5
Beamø0.256 0.217
emitting
side
7
2.1 0.083
11.6 0.457
11 0.433 0.276
Beamreceiving
side
Beamemitting
side
Free-cut
FD-R60
Free-cut
FD-L32H
Complete thread 6.5 0.256 or more
7
9
0.276
0.354
2
5.2
0.079
0.205
2.4 0.094
3.5 0.138
25 0.984
20 0.787
2,000 78.740
2,000 78.740
(ø2.5) (ø0.098)
Model No. tube (m-PPE)
Enclosure [ZDC2 (Nickel plated)]
ø3 ø0.118
Toothed lock washer M4
[Stainless steel (SUS304)]
Hexagon nut M4
[Stainless steel (SUS304)]
ø1.3 ø0.051
4.2 0.165
ø8.5 ø0.335 7 0.276
ø0.75 ø0.030 fiber core × 1 (Acrylic)
Sheath ø1.3 ø0.051 (Polyethylene)
FD-R61Y
Free-cut
M6 × 0.75 0.030
2
0.079
ø4.5
ø0.177
Hexagon nut M6
[Stainless steel
(SUS304)]
ø1.2
ø0.047
(30)
Fixing bracket
(1.181)
[Stainless steel (SUS303)] (ø3.2) (ø0.126) Model No. tube (m-PPE)
R5±1
ø5 ø0.197
R0.197±0.039
-0.1 -0.004 2 0.079
ø6 ø0.236-0.13
-0.005
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
ø1.2 ø0.047 Stainless steel pipe
90°±5
[Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
5 0.197
Mounting reference
surface
(Screw periphery)
ø11 ø0.433
10
0.394
11
0.433
5
0.197
2,000 78.740
2-ø2.2 ø0.087
5.5
0.217
8 0.315
Hexagon nut M6 [stainless steel (SUS304)]
2 0.079
M6 × 0.75 0.030
10
ø11 ø0.433 0.394
(Set screw tightening range)
Details of
sensing part
2-ø2.2 ø0.087
(30)
(1.181)
8
0.315
Chemical / Oilresistant
Heatresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Reflective
Type
5.1 0.201
Others
ø1
ø0.039
(ø2.5) (ø0.098)
4.5 0.177
1,000 39.370
6
10.7
(1) (0.039)
0.236 0.421
(3.1) (0.122)
Head [stainless steel (SUS304)]
Toothed lock washer M6 [stainless steel (SUS304)]
Retroreflective
Type
Retroreflective
Type
ø1
ø0.039 ø1.5 ø0.059
2
0.079
Wide
Beam
Convergent
Reflective
Type
Thru-beam
Type
FD-S21
Cap [stainless steel (SUS304-CSP)]
Narrow
Beam
Fiber
Dimensions
10 0.394
7 mm 0.276 in or more
(complete thread)
Small
Spot
5 0.197
Toothed lock
13
washer M6
0.512
[Stainless steel
(SUS304)]
4 0.157
Flat
Type
Vacuumresistant
2-ø2.2 ø0.087
(30)
(1.181)
M4 × 0.7 0.028
3
0.118
Cap [Stainless steel (SUS304-CSP)]
7 0.276
10 0.394
4.5 5.1
0.177 0.201
ø2.2
ø0.087
Protective tube
ø1.2 ø0.047 (Polyolefin)
Enclosure [ZDC2 (Nickel plated)]
11.3 0.445
1.8
0.071 12.5 0.492
Cylindrical
Type
Sleeve
10.7
0.421
ø2.3 ø0.091
3.8 0.150
2.1 0.083
Square Head
Type
Complete thread
10.8 0.425 or more
5.5
8
0.217
0.315
3.7
0.146
M3 ×
0.5 0.020 3.5 0.138
Resin plug (ABS)
Fibers
Super
Quality
ø6.5 5.5
ø0.256 0.217
3-ø3.2 ø0.126 (0.5 0.020 deep, on both sides)
Complete thread
10.8 0.425 or more
5.5
8
0.217
0.315
3.7
0.146
M3 ×
3.5 0.138
0.5 0.020
11.3 0.445
12.5 0.492
How to read
Model No.
Toothed lock washer M3 [Stainless steel (SUS304)]
3.8 0.150
FD-R32EG,
FD-R32EG outlineFD-R34EG
drawing
Choose
by shape/
application
Earlier models
comparison
table
Enclosure [ZDC2 (Nickel plated)]
2-ø3.2 ø0.126 mounting holes, ø5.7 ø0.224
spot facing, 2.6 0.102 deep
Fiber
Selection
Guide
Model
ø1
ø0.039
(30)
(1.181)
1.7
0.067
1.8 0.071
ø2.3 ø0.091
ø1.5 ø0.059 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
Enclosure (ABS)
7.5
0.295
7.3
0.287
5.5
0.217
3.7
0.146
2-ø2.2 ø0.087
(16.7)
(0.657)
Tough
Fiber
Free-cut
FD-R31G outline drawing
Complete thread 10.8 0.425 or more
4,000 157.480
4.5 0.177
30 1.181
6.5 0.256
FD-R31G
New product
introduction
Sheath
ø1 ø0.039
(Polyethylene)
End bracket
[Stainless steel (SUS303)]
7
11 11.6
0.276 0.433 0.457
Resin plug (ABS)
(ø2.5) (ø0.098) Model No. tube (m-PPE)
Amplifiers
FX-500
series
FX-100
series
INDEX
ø1.0 ø0.039 fiber core × 1 (PMMA)
Outer sheath ø2.2 ø0.087 [PFA (Fluorine resin)]
Inner sheath ø1.8 ø0.071 (Polyethylene)
ø0.25 ø0.010 fiber core × 2 (PMMA)
(each beam-emitting part and beam-receiving part)
64
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
FD-S30
FD-S31
2
0.079
2,000
78.740
Resin plug (ABS)
(20)
(0.787)
8
0.315
4
Set screw
tightening range 0.157
ø2
ø0.079
2
0.079
8
0.315
(19.7) (0.776)
10.2 0.402
(0.3) (0.012)
ø2.2
ø0.087
How to read
Model No
Earlier models
comparison
table
ø3 ø0.118 -0.07 -0.003
-0.10 -0.004
Mounting reference surface
(Periphery)
(ø4.33) (ø0.170)
ø1
ø0.039 (ø2) (ø0.079) Model No. tube (m-PPE)
ø1.8
ø0.071
Super
Quality
Threaded
Type
Square Head
Type
ø2
ø0.079
ø3 ø0.118 -0.07 -0.003
-0.1 -0.004
Mounting reference surface (Periphery)
FD-S32
Free-cut
2,000
78.740
ø1
4 0.157 (Set screw tightening range)
ø0.039
(30)
(1.181)
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 Fiber core × 1 (Acryic)
Sheath ø1 ø0.039 (Polyethylene)
End bracket [Stainless steel (SUS303)]
End bracket [Stainless steel (SUS303)]
Fibers
Free-cut
FD-S32W
Free-cut
2.7
0.106
2,000 78.740
(30)
(1.181)
15 0.591
7
0.276
Cylindrical
Type
2.7
0.106
15 0.591
2,000 78.740
(30) (1.181)
7
0.276
2-ø1.3 ø0.051
2-ø1.3 ø0.051
ø3 ø0.118
Sleeve
ø3 ø0.118
End bracket
[Stainless steel
(SUS303)]
Flat
Type
End bracket
[Stainless steel
(SUS303)]
(ø2.5) (ø0.098) Model No. tube (m-PPE)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
(ø2.5) (ø0.098) Model No. tube (m-PPE)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Small
Spot
Narrow
Beam
Wide
Beam
FD-S33GW
Free-cut
Convergent
Reflective
Type
(30) (1.181)
16
0.630
Beam-emitting
side
ø3 ø0.118
End bracket
[Stainless steel
(SUS303)]
Details of
sensing part
Beam-receiving
side
(ø2) (ø0.079) Model No. tube (m-PPE)
Protective tube
[PFA (Fluorine resin)]
Semi-custom
fibers
2-ø1.3 ø0.051
FD-S32W
Cover [PFA (Fluorine resin)]
Sheath ø1 ø0.039 (Polyethylene)
Sheath ø1.3 ø0.051 (Polyethylene)
ø1.0 ø0.039 fiber core × 1 (PMMA)
Outer sheath ø1.3 ø0.051 (Polyethylene)
2.7
0.106
Fiber
Options
2,000 78.740
1,500 59.055
ø4 ø0.157
ø5.5
ø0.217
ø1.3 ø0.051
Heatresistant
Liquid Leak /
Liquid Detection
ø1 ø0.039
Chemical / Oilresistant
Vacuumresistant
Free-cut
2,000 78.740
15 0.591
7
0.276
Retroreflective
Type
FD-S60Y
Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)
FD-S32
Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA)
FD-V30
Free-cut
FD-V30W
Free-cut
Fiber
Dimensions
2.8 0.110
Thru-beam
Type
Beam
axis
15 0.591
Retroreflective
Type
A
Reflective
Type
Others
Amplifiers
FX-500
series
ø1.5
ø0.059
10
0.394
Set screw tightening range
15 0.591
ø3 ø0.118
Sleeve [Stainless
steel (SUS303)]
End bracket
[Stainless steel
(SUS303)]
View A
2.8 0.110
Beam
axis
15 0.591
2,000 78.740
2-ø1 ø0.039
(30) (1.181)
A
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
End bracket
[Stainless steel
(SUS303)]
2 0.079
2.5 0.098
1.3 0.051
1.3 0.051
Shielding plate (Polyester)
FX-100
series
INDEX
FD-S33GW
2,000 78.740
2-ø1 ø0.039
(30) (1.181)
ø3 ø0.118
View A
2 0.079
2.5 0.098
Set screw tightening range
15 0.591
ø1.5
ø0.059
Sleeve [Stainless
steel (SUS304)]
10
0.394
Shielding plate (Polyester)
(ø2) (ø0.079) Model No. tube (m-PPE)
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
65
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Dimensions are listed in the order of thru-beam type, retroreflective type,
and reflective type, and in alphabetic order of the Model No.
Reflective type fibers
FD-V50
Free-cut
FD-Z20HBW
10 0.394
0.5 0.020
1.05 0.041
Beam
axis
15 0.591
20 0.787
A
2,000 78.740
2-ø2.2 ø0.087
(30) (1.181)
5 0.197
End bracket
[Stainless steel
(SUS303)]
View A
2
0.079 3.5 0.138
2.5 0.098
2.2
0.087
10 4 0.157
0.394
1,000 39.370
ø2.2 ø0.087 hole, ø3.6 ø0.142
spot facing, 1.4 0.055 deep
2-ø1
4-R1 R0.039 (30)
ø0.039
(1.181)
Beam axis
(ø3.2) (ø0.126) Model No. tube (m-PPE)
Choose
by shape/
application
Super
Quality
Threaded
Type
Square Head
Type
Shielding plate
(Polyester)
Cylindrical
Type
FD-Z20W
Free-cut
FD-Z40HBW
Free-cut
7
0.276
3.5 0.138
1.2 0.047
2.5 0.098
10
0.394 4 0.157
5 0.197
ø3.2 ø0.126 hole, ø5.6 ø0.220
spot facing, 2.2 0.087 deep
1
3.5 0.138
0.039
1.05 0.041
1,000 39.370
ø2.2 ø0.087 hole, ø3.6 ø0.142
spot facing, 1.4 0.055 deep
4-R1 R0.039
2-ø1
(30) (1.181)
ø0.039
Beam axis
11 0.433
2.2 0.087
14 6.5 0.256
0.551
(ø2) (ø0.079) Model No. tube (m-PPE)
Inner pipe [Stainless steel (SUS304)]
Enclosure (PC)
1.05 0.041
FD-Z20HBW
ø2.4 ø0.094
Inner pipe
[Stainless steel (SUS304)]
Beam axis
0.9
0.035
ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
FD-Z40W
Free-cut
1
0.039
7
0.276
7
0.276
2.2
ø2.4 ø0.094 0.087
Prism (PMMA)
Beam axis
FD-Z50HW
Free-cut
15
0.591
Lens (BK7)
1 0.039
Retroreflective
Type
Chemical / Oilresistant
Enclosure (PC)
5.2 0.205
Beam axis
Vacuumresistant
Liquid Leak /
Liquid Detection
2,000 78.740
4.6 0.181 9.5 0.374
2-ø2.2
ø0.087
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
Fiber
Options
Semi-custom
fibers
Assembly dimensions with MS-FD-2 (attached mounting bracket)
Lens (BK7)
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
9.5
0.374 4.6 0.181
12.2 0.480
5 0.197
10.2
0.402
1.2 0.047
1 0.039
15
2,000 78.740
0.591
2-M3 × 0.5 0.020
6
0.236
Beam axis
14 0.551
Retroreflective
Type
3.3 0.130
4 0.157
7 0.276
5.2 0.205
Fiber
Dimensions
Thru-beam
Type
4 0.157
3.3 0.130
FD-V50
Convergent
Reflective
Type
Heatresistant
2,000 78.740
ø3.2 ø0.126 hole, ø5.8 ø0.228
spot facing, 2.2 0.078 deep
4-R1 R0.039
2-ø1.3
(30) (1.181)
ø0.051
(ø2.5) (ø0.098) Model No. tube (m-PPE)
Inner pipe [Stainless steel (SUS304)]
Enclosure (PC)
1.05 0.041
Wide
Beam
ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
3.5 0.138
1.2 0.047
3.5
0.138
3.5 0.138
14 6.5
0.051 0.256
Flat
Type
Narrow
Beam
2-ø1.3
ø0.051
(ø2.5) (ø0.098) Model
2.7
0.106 No. tube (m-PPE)
1.6 0.063
7
0.276
Sleeve
Small
Spot
2,000 78.740
3.5 4-R1 R0.039
0.138
Enclosure (PC)
(30)
(2.2)
(0.087) (1.181)
3.5 0.138
7
0.276
2.2 0.087
Prism
(PMMA)
ø1.5
ø0.059
Earlier models
comparison
table
Fibers
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
1.7 0.067
2 0.079
How to read
Model No.
ø0.5 ø0.020 fiber core × 1 (PMMA)
0.6 0.024 Sheath ø1 ø0.039 (Polyethylene)
2.3 0.091
3 0.118
0.5
0.020
Fiber
Selection
Guide
Model
(2.2) (0.087) (ø2) (ø0.079) Model No. tube (m-PPE)
Inner pipe
ø1.5 [Stainless steel (SUS304)]
Enclosure (PC)
ø0.059
7 1 0.039
2.1 0.083
0.276
ø5 ø0.197
ø2 ø0.079
Sleeve [Stainless
steel (SUS304)]
Set screw tightening range
10
0.394
Tough
Fiber
Free-cut
4.5 0.177
New product
introduction
MS-FD-2 Mounting bracket
[Stainless steel(SUS304)]
Enclosure (PC)
2-ø2.2
ø0.087
Reflective
Type
Others
FD-Z40HBW ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)
Amplifiers
FR-Z50W
FX-500
series
FX-100
series
INDEX
66
DIMENSIONS (Unit: mm in)
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Vacuum-resistant Atmospheric side fiber
FT-J8
Free-cut
(Accessory for vacuum-resistant fiber)
Photo-terminal side
Model
Choose
by shape/
application
4 0.157
How to read
Model No
10
0.394 ø3.6
ø0.142
ø2.2
ø0.087
11
0.433
Mounting cap nut opposing faces 8 0.315
[Stainless steel (SUS)]
ø4
ø0.157
Earlier models
comparison
table
Amplifier side
2,000 78.740
Joint [Brass (C3604) (Nickel plated)]
Fibers
Super
Quality
Threaded
Type
Square Head
Type
FB-1
Fiber bender (Optional)
Cylindrical
Type
Flat
Type
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
ø4.5 ø0.177 spiral tube
[Stainless steel (SUS)]
Material: PP (Containing steel blade)
36
1.417
6
0.236
2
0.079
Mounting hole
Chamber wall or flange
ø5.5 to ø6.0
ø0.217 to ø0.236
M5 × 0.8 0.031 thread
[Stainless steel (SUS)]
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
14
0.551
3.7
0.146
M2.6 × 0.45 0.018 internal
thread, 3 0.118 deep
FDP-□
Vacuum-resistant side-view lens (Optional)
10.5
0.413
L
15
0.591
3
0.118
15
0.591
ø7 ø0.276 spiral tube
[Stainless steel (SUS)]
ø8 ø0.315 [Brass (Nickel plated)]
M6 × 0.75 0.030 internal thread, 5 0.197 deep
Heat resistant adhesive
9.5 0.374
7.3 0.287
3.6
0.142
4.5
0.177
2-ø3.1 ø0.122
2.8 0.110
6.6
0.260
ø1 ø0.039 vent hole
5.5
0.217
3.6
0.142
ø18
ø0.709
M2.6 × 0.45 0.018,
3.2 0.126 deep
M10 × 1 0.039 thread
[Brass (Nickel plated)]
• Length L
FTP-500, FTP-N500, FDP-N500, FDP-500
Enclosure
[Stainless steel (SUS)]
ø11
ø0.433
M6 × 0.75 0.030 thread
[Stainless steel (SUS)]
Model No.
Material: Enclosure........Aluminum alloy
(A6061-T6)
Lens...............BK-7
4.7
0.185
15
0.591
3.7
0.146
ø4
ø0.157
Lens (BK7)
2
0.079
M3 × 0.5 0.020 internal thread, 5 0.197 deep
Vacuum-resistant expansion lens (Optional)
9.2
0.362
6
0.236
4
0.157
L
15
0.591
ø3.8 ø0.150 spiral tube
[Stainless steel (SUS)]
ø5 ø0.197 [Brass (Nickel plated)]
M5 × 0.8 0.031 thread
O-ring
Spring washer ø10 ø0.394
Opposing faces 8 0.315, thickness 3 0.118
ø3.6 ø0.142 lens
ø1 ø0.039 vent hole
Reflective
Type
5
0.197
M4 × 0.7 0.028 internal thread, 5 0.197 deep
FTP-N□
Hole
FV-SV2
M8 × 1 0.039 thread
[Brass (Nickel plated)]
ø6 ø0.236 [Brass (Nickel plated)]
FV-BR1 Photo-terminal (for vacuum-resistant) (with vacuum-resistant fiber)
Semi-custom
fibers
Retroreflective
Type
ø15
ø0.591
8.6
0.341
Fiber
Options
Thru-beam
Type
15
0.591
3
0.118
20
0.787
FV-LE1
Fiber
Dimensions
L
15
0.591
Small
Spot
Narrow
Beam
Protective tube (Optional)
FTP-□, FDP-N□
52
2.047
40
1.575
Sleeve
FTP-□ FDP-□
Length L
500 +100 19.685 +0.394
0
FTP-1000, FTP-N1000, FDP-N1000, FDP-1000
1,000 +100 39.370 +0.394
0
FTP-1500, FTP-N1500, FDP-N1500, FDP-1500
1,500 +100 59.055 +0.394
0
67
DIMENSIONS (Unit: mm in)
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
FX-AT2 Attachment for fixed-length fiber (Accessory for fixed-length fiber)
Attachment for ø2.2 mm ø0.087 in fiber
9.1
0.358
7.5
0.295
2-ø2.3
ø0.091
8.2
0.323
Fiber
Selection
Guide
Model
Choose
by shape/
application
11.2 16
0.441 0.630
7
0.276
7
0.276
5
0.197
4
0.157
14
0.551
7
13
0.276 0.512
Tough
Fiber
(Accessory for ø2.2 mm ø0.087 in fiber)
8
0.315
6
0.236
Material: POM
FX-AT3
New product
introduction
How to read
Model No.
Material: Polycarbonate
Earlier models
comparison
table
FX-AT4
Attachment for ø1 mm ø0.039 in fiber
FX-AT5
Attachment for ø1.3 mm ø0.051 in fiber
(Accessory for ø1 mm ø0.039 in fiber)
20.5
0.807
3
0.118
4
0.157
3.5
0.138
6.5
2 0.256
0.079
ø2.2
ø0.087
(Accessory for ø1 mm ø0.039 in / ø1.3 mm ø0.051 in mixed fiber)
3
0.118
4
0.157
3.5
0.138
2
0.079
ø2.2
ø0.087
6.5
0.256
5 0.197
15
7
0.591 0.276
5 0.197
1.7
0.067
ø2.2
ø0.087
Material: H
older..............PA (Nylon 66)
Ground.............POM
3.5
0.138
2
0.079
ø2.2
ø0.087
FX-CT2
ø4
ø0.157
9.2
0.362
ø4.3
ø0.169
Material: Enclosure............ Brass
(Nickel plated)
Lens.................... Glass
15
7
0.591 0.276
5 0.197
1.7
0.067
ø2.2
ø0.087
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Fiber cutter (Accessory for free-cut type fiber)
ø1.4
ø0.055
Small
Spot
Narrow
Beam
Wide
Beam
8
0.315
45
1.772
ø1.1
ø0.043
Super
Quality
Flat
Type
Convergent
Reflective
Type
Retroreflective
Type
25
0.984
Chemical / Oilresistant
Heatresistant
Material: ABS
FX-LE2
Super-expansion lens (Optional)
22.2
0.874
17
0.669
8
5 0.315
0.197
Lens
Knurled surface
ø9
ø0.354
6
0.236
ø7
ø0.276
ø12 ø10.2
ø0.472 ø0.402
M2.6 × 0.45 0.018 internal
thread, 3 0.118 deep
FX-MR1
Pinpoint spot lens (Optional)
Lens
Lens Effective dia.:
ø3.3 ø0.130
Semi-custom
fibers
M4 × 0.7 0.028 internal
thread, 6 0.236 deep
ℓ = 36 to 37
1.417 to 1.457
Note: In order to obtain a ø0.5 mm
ø0.02 in spot, it is necessary to keep
M4 × 0.7 0.028 internal
“ ℓ ”, in the above figure, within the
thread, 6 0.236 deep
specified range.
Material: Enclosure............ Aluminum (Black ALMITE)
Lens.................... Glass
Fiber
Dimensions
FX-MR2
Zoom lens (Optional)
27.1
1.067
20
0.787
Mounting drawing
with FD-42G
Liquid Leak /
Liquid Detection
Fiber
Options
Material: Enclosure............ Stainless steel (SUS303)
Lens.................... Glass
ø6
ø0.236
ø1.4
ø0.055
14.6
0.575
Expansion lens (Optional)
20.2
0.795
11
0.433
ø1.4
ø0.055
Fibers
Vacuumresistant
FX-LE1
ø4
ø0.157
6.5
0.256
5 0.197
Material: Holder..............PA (Nylon 66)
Ground.............POM
FX-AT6 Attachment for ø1 mm ø0.039 in / ø1.3 mm ø0.051 in mixed fiber
20.5
0.807
3
0.118
4
0.157
ø1.1
ø0.043
ø1.1
ø0.043
5 0.197
7
15
0.591 0.276
5 0.197
1.7
0.067
ø2.2
ø0.087
Material:
Holder.....PA (Nylon 66)
Ground...POM
(Accessory for ø1.3 mm ø0.051 in fiber)
20.5
0.807
4.5
0.177
Thru-beam
Type
Retroreflective
Type
Reflective
Type
7
0.276
Others
ø8
ø0.315
ø7.1
ø0.280
M4 × 0.7 0.028 internal
thread, 6 0.236 deep
Material: Enclosure............ Aluminum (Black ALMITE)
Lens.................... Glass
Amplifiers
FX-500
series
FX-100
series
INDEX
68
New product
introduction
Tough
Fiber
DIMENSIONS (Unit: mm in)
FX-MR3
Finest spot lens (Optional)
FX-MR5
Model
15
0.591
Choose
by shape/
application
ø4 ø0.157
10.3
0.406
20.3
0.799
8 0.315
3 0.118
2.5
0.098
4.5 0.177
M3 × 0.5 0.020
internal thread
Earlier models
comparison
table
ø5 ø0.197
lens
3.3
0.130
ℓ = 27.5 1.083
4
0.157
5
0.197
Zoom lens (Optional)
6.3
0.248
Mounting drawing with FD-EG30
Fiber
Selection
Guide
How to read
Model No
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
Knurled
Material: E
nclosure............ Aluminum (Black ALMITE)
Lens.................... Glass
Note: When inserting the fiber, insert fully till it stops.
Material: Enclosure............ PBT (Black)
Lens.................... Glass
Fibers
2-M3 × 0.5 0.020
thru-hole threads
7
0.276
M4 × 0.7 0.028 internal
thread, 11 0.433 deep
3.15
0.124
NT-FX-MR5 (exclusive nut) is attached.
Super
Quality
Threaded
Type
FX-MR6
Finest spot lens (Optional)
Square Head
Type
Mounting drawing with FD-EG31
Cylindrical
Type
Caulking part
15.3
0.602
Lens
Flat knurl
M3 × 0.5 0.020
ø4
ø0.157
16
0.630
Wide
Beam
Holder [Stainless steel
Lens (Acrylic) (SUS303)]
ø5 ø0.197
Narrow
Beam
M3×0.5 0.020
ø5
ø0.197
ø4.3
ø0.169
ℓ = 28.5 1.122
Small
Spot
Convergent
Reflective
Type
Finest spot lens (Optional)
5
0.197
Sleeve
Flat
Type
FX-MR7
5
0.197
Laurette of straight pattern
Mounting drawing with FD-R31G/R32EG/R33EG/R34EG
ℓ=27.8 1.094
Material: Enclosure............ Aluminum (Black ALMITE)
Lens.................... Acrylic
Note: When inserting the fiber, insert fully till it stops.
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
FX-MR8
Vacuumresistant
Zoom lens (Optional)
Caulking part
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Lens (BK7)
Holder [Stainless steel
(SUS303)]
M3×0.5 0.020
ø4.3
ø0.169
ø5
ø0.197
Laurette of straight pattern
Mounting drawing with FD-R31G/R32EG/R33EG/R34EG
ℓ=22.8 to 27.5
0.898 to 1.083
Parallel light lens (Optional)
Caulking part
15
0.591
5
0.197
ø4.3
ø0.169
FX-MR9
Lens (BK7)
Holder [Stainless steel
(SUS303)]
10
0.394
5
0.197
M3×0.5 0.020
ø5
ø0.197
Laurette of straight pattern
Mounting drawing with FD-R31G/R32EG/R33EG/R34EG
ℓ=22.5 0.886
69
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
FX-SV1 Side-view lens (Optional)
MS-EX3
0.5
0.020
ø4
ø0.157
Rod prism
12.2
0.480
10.2
0.402
4.9
0.193
Anti-slip rubber sheet (8 × 9.5 × 1)
(0.315 × 0.374 × 0.039)
5
0.197
6
0.236
t1.2
10
0.394
M2.6 × 0.45 0.018 internal
thread, 3 0.118 deep
16
0.630
23
0.906
Material: Enclosure............ Brass (Nickel plated)
Lens.................... Glass
MS-FD-3
Fiber mounting bracket
3.3 0.130
C1 C0.039
RF-003
R2.5 R0.098
(2-R)
7
0.276
Cover
[Stainless steel (SUS304)]
(88°)
(90°)
6.9
0.272
How to read
Model No.
Earlier models
comparison
table
14
0.551
10 0.394
19 28
(Effective reflector width) 0.748 1.102
1 0.039
3.2
0.126
4.3
0.169
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Flat
Type
Reflector
(Norbornene resin)
Small
Spot
Narrow
Beam
3.5 0.138
0.4
0.016
Choose
by shape/
application
Sleeve
3.9 0.154
(88°)
(90°)
3.3
0.130
10 0.394
(Effective reflector width)
(2-R)
1.1
0.043
19
0.748
3.2 0.126
R1.6
R0.063
10.6
0.417
Fiber
Selection
Guide
Model
4
0.157
Reflector for FR-KZ50E/KZ50H
10.1
5 0.398
0.197
5
0.197 10
0.394
3.3
0.130
Accessory for FR-KZ50E/KZ50H
3.3 0.130
3-R0.5 R0.020
5 0.197
4
0.157
Material: Stainless steel (SUS304)
Material: Brass (Nickel plated)
Accessory for FT-KV40/FT-KV40W
(11)
(0.433)
3.2
0.126
Tough
Fiber
2-M3 × 0.5 0.020
9.8
0.386
0.8
8.5
0.031
0.335
2-ø3.5 ø0.138 mounting holes
Fiber mounting bracket
Accessory for FD-Z50HW, FR-KZ50E/KZ50H/Z50HW, FD-H30-KZ1V-S
4
0.157
8.7 0.343
Knurled surface
8
0.315 2.5
0.098
MS-FD-2
Mounting bracket for FX-MR2 (Accessory for FX-MR2)
New product
introduction
6.9
0.272
Wide
Beam
Convergent
Reflective
Type
Material: Stainless steel (SUS304)
Retroreflective
Type
RF-13
Reflective tape for FR-Z50HW
RF-210
Reflector (Optional)
Accessory for FR-Z50HW
Vacuumresistant
12.8
0.504
30
1.181
Rear surface
(Pressure-sensitive
adhesive)
Heatresistant
33.3
1.311
30
1.181
0.5
0.020
11
0.433
Reflective surface (Acrylic)
Material : Acrylic (Reflective surface)
Liquid Leak /
Liquid Detection
M3 nut mounting holes
(for mounting at the back)
Reflector
Base
3.2
0.126
25
0.984
10
0.394
2-ø3.4 ø0.134 thru-holes
(for mounting at the side)
2-ø3.4 ø0.134 holes,
6 0.236 deep
(for mounting at the back)
2-M3 nut mounting holes
(for mounting at the side)
Material: A
crylic (Reflector)
ABS (Base)
Two M3 (length 8 mm 0.315 in) screws with washers and two nuts are attached.
RF-220
Reflector (Optional)
RF-230
35.3
1.390
34.3
42.3 1.350
1.665
8 0.315
Reflector (Optional)
50.3
1.980
25
0.984
Material: Acrylic (Reflector)
ABS (Base)
2-ø3.6 ø0.142
mounting holes
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
FX-500
series
(30)
(1.181)
8.3
0.327
Semi-custom
fibers
Amplifiers
4 0.157
3.3
0.130
Fiber
Options
Others
49.3
59.3 1.941
2.335
(21)
(0.827)
Chemical / Oilresistant
10
0.394
FX-100
series
5 0.197
40
1.575
Material: Acrylic (Reflector)
ABS (Base)
3.3
0.130
2-ø4.6 ø0.181
mounting holes
8.3
0.327
INDEX
70
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Digital Fiber Sensor
FX-500 SERIES Ver.2
At the industry’s leading edge
Model
Choose
by shape/
application
How to read
Model No
Conforming to
EMC Directive
Ver.2
Listing
Earlier models
comparison
table
Certified
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
PNP output
type available
Timer
Automatic
sensitivity setting
Test input
Interference Light intensity
monitor
prevention
* There is no change in Model No. and price due to version upgrade.
* Cover opened state is shown.
Improved the operability and visibility of the operation keys
External sync.
Operation keys (setting switch and MODE key) have been renewed to be easy to operate. Also, the color of the keys
has been changed from black to light gray to achieve good visibility in dim light.
Upgraded (Ver. 2)
Retroreflective
Type
Previous
Chemical / Oilresistant
Setting switch MODE key
Setting switch
MODE key
Heatresistant
Clicking touch!
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
High stability!
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
When the FX-500 series is used together with our super quality fiber, the incident light intensity variation among units
is decreased to only 1/4 of that of conventional models.
By being close to absolute values instead of modified digital values, changes in detection that could not be found in
the past can now be monitored.
Super quality fiber
FX-500 series
Retroreflective
Type
Incident light
intensities are
stable.
Threshold Incident light
value
intensity
Reflective
Type
Others
Incident light intensity
1/4
Unify the threshold value
Can control by
using just one
threshold value.
incident light
intensity variation
[from previous]
Amplifiers
FX-500
series
FX-100
series
Previous amplifier
Variation in the threshold value
Threshold Incident light
value
intensity
Incident light intensity
L
D
MODE
L
D
MODE
L
INDEX
D
MODE
L
MODE
D
Large variation in
incident
light intensity.
Requires setting
different
threshold values
for each sensor.
71
A quality that surpassed that of standard fibers!
New fibers developed using a new manufacturing method adopted by our own factory along with a persistent quality
control system.
The basic performance of a standard fiber is greatly enhanced!
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Variation in emission amount of the fiber core
is controlled down to less than ±10 %,
achieving a stable detection.
• Beam axis deviation: Thru-beam type within ±2 °,
Reflective type within ±3 °
• Beam axis centering precison: within ± 150 μm
Expanded temperature range
Ambient temperature [–40 to +70 °C –40 to +158 °F in previous model]
– 55 to +80 °C
– 67 to +176 °F
1.2
times
more than
previous model
Choose
by shape/
application
ø2.2 mm ø0.087 in standard fiber
How to read
Model No.
Previous
Stable emission amount
New material
± 10
Single core standard fiber
with high flexibility
Earlier models
comparison
table
In general, high-flexibility
types adopt a multi-fiber core,
which may result in large
variation in light emission.
Fibers
R4
More flexible!
Super
Quality
Threaded
Type
Bending radius [Previous model is R25 mm R0.984 in]
R4 mm
R0.157in
Square Head
Type
1/6
of that of
previous model
Cylindrical
Type
Sleeve
Integrated high-precision plug
The centering precision of
the fiber core attached to the
inserting plug is doubled.
As the insertion precision is
increased, the variation among
units can be greatly suppressed.
• Centering precision: within ± 40 μm
More bendable!
Flat
Type
Small
Spot
Bending durability [Previous model is 1,000 times]
10 million
times
Narrow
Beam
10,000 times
more than previous model
Wide
Beam
* Bending conditons
Bending radius: R10 mm R 0.394 in,
Reciprocating bending 180°
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
H y p e r
Max. 25 μs response time
HYPR mode incorporated
FX-500 with its high response time contributes to
improve productivity.
FX-500 in combination with small diameter fibers which
can handle challenging detections, allows long sensing
range.
7RXJK
FX-500
FD-41
Previous
FD-NFM2
Max.
Vacuumresistant
5.7
times! (Note)
longer than the previous model
Liquid Leak /
Liquid Detection
Fiber
Options
HYPR mode
FX-301 (LONG mode)
Performing minute object detection when using a small
diameter fiber is now possible with a high response time
and longer sensing range.
Semi-custom
fibers
Note: When using FD-NFM2.
Fiber
Dimensions
Thru-beam
Type
So accurate! Sharp detection with suppressed hysteresis
FX-500 with its
accurate detection
catches fractional
differences in
light intensity, achieving
high precision and
solving low-hysteresis
applications.
• Long range detection of small objects with small
difference in light intensity H-02 mode
Retroreflective
Type
• Highly accurate detection while
avoiding saturation H-01 mode
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
Retroreflective
FR-Z50HW
type fiber
FT-A11
Reflector
INDEX
72
New product
introduction
Tough
Fiber
Flat display with wide viewing angle
The large and high-contrast 7-segment display of high
luminance provides clear visibility from a wide angle of
view.
Pr
ev
i ou
s
sp
ac
e
re
qu
Fiber
Selection
Guide
i re
1/3
nt
Reduced to
Choose
by shape/
application
me
Compact cover does not get in the way
Model
of the previous model’s size
Clearly visible even
from sideways
How to read
Model No
Earlier models
comparison
table
R23 mm
R0.906 in
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Resolves variation in displayed incident light
intensity
Display adjustment setting
The variation in display can be adjusted to random
values. This helps to define proper instruction in a work
order.
Current incident light intensity
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Display
adjustment
setting
Unify incident light intensity into any value
Stable detection over long and short periods
Saves maintenance time
The “four-chemical emitting element”, which we are the
first to incorporate to maintain a stable level of light emission, has now become an industry standard. FX-500
series continues to adopt the same emitting element as
well as the “APC (Auto Power Control) circuit” which improves stability in short periods such as when the power
is turned on.
This function performs automatic setting to threshold
value by checking the incident light intensity at desired
intervals in order to follow the changes in the light
amount resulting from changes in the environment over
long periods (such as dust). This contributes to reduction
in maintenance hours.
Suitable for preventative maintenance FX-502(P)
FX-505(P)-C2
Self-diagnosis output
■ Detect deterioration in light intensity
(e.g. Useful in dusty environment)
Stabilized emission amount
FX-502(P) / 505(P)-C2 can set Output 2 as a selfdiagnosis output. When the teaching of Output
1’s threshold value is carried out, Output 2 is set
concurrently with the setting randomly shifted by the
amount of surplus of threshold value. Light intensity
deterioration due to fiber breakage or dust accumulation
can be notified as an alarm output.
Threshold tracking function
Self-diagnosis can be used with the threshold
tracking function for added effectiveness.
Stable detection while being eco-friendly
Emission power & gain setting
In cases when the incident
light intensity is saturated,
the light emitting amount
can be adjusted to the optimal level by AUTO without
changing the response time.
This allows stable detection
with an optimal S/N ratio
and saves energy by controlling the emitting electric
current.
Detecting a transparent sheet
AUTO
Normal
Object present
Object absent
Saturated
Auto mode (AUTO) and 3-level manual mode (H / M / L [fine-adjustable]) are incorporated.
73
Built-in logic functions
New product
introduction
No PLC necessary, saving material and programming costs
Logical calculation functions
3 logical calculations (AND, OR,
XOR) are available with fiber
sensor only. 3 logical operations
can be selected against Output 1.
Additional controller is not
required so both wire-saving and
cost reduction can be achieved.
Calculation of two neighboring amplifiers
Lower side Output 1 Calculation result
output
Upper side Output 1 Normal operation
Equipped with 5 timer types
A wide variety of timer control
operations can be carried out by
fiber sensors only.
Time chart
Communication direction (Up to 12 units)
Calculation of two outputs in one amplifier
Set to L-ON
Sensing
condition
FX-502(P) / 505(P)-C2
T1
ON-delay
Detection fiber
Output 1 Calculation result output
One-shot
FX-502(P) / 505(P)-C2
External input
(sensor, contact, PLC, etc.)
Synchronization fiber
Output 1 Calculation result output
T1
OFF-delay
Output 2 Normal output operation
Calculation of one amplifier and external input
Beamreceived
Beaminterrupted
ON
OFF
T1
T1
ON
OFF
T1
ON/OFF
-delay
T1
ON-delay/
One-shot
T1
ON
OFF
T2
T2
ON
OFF
ON
OFF
Timer period: 0.05 ms to 32 s
Output 1 has ON / OFF-delay and ON-delay / One-shot timers are available.
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Analog output cable type
FX-505(P)-C2
To monitor the sensing of objects, a 4 to 20 mA analog
current is output in respond to the digital value of the
incident light intensity.
Edge tracking of film or sheet
20
Output current (mA)
Actual position
Drift position
Incident light intensity (digit)
Cylindrical
Type
The number of data banks used for saving the setup
conditions of the amplifirer is increased to eight. Setup
conditions can be saved and loaded to make setup
changes easy at a worksite where multiple models are
manufactured.
Sleeve
Remote control improves work FX-502(P)
FX-505(P)-C2
efficiency by external input
Work efficiency can be improved by operating via PLC
output or other external signal.
(FX-502(P) can operate via external signal when
switching from Output 2 to external input.)
4
0
Smooth setup changes by 8 data banks
4,000/8,000
The drifting path can be monitored as
the light intensity changes.
Functions operable by external input
Full-auto / Limit / 2-point teaching
Display adjustment setting
Data bank load / save
Logical calculation (self-unit only)
Emission halt
Copying function lock (self-unit only)
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
An optical communication function allows
sensors to be adjusted simultaneously
The data that is currently set can be copied and saved
all at once for all amplifiers connected together from the
right side thanks to the optical communication function.
This greatly reduces troublesome setup tasks and
makes setup much smoother.
No need to specify a main unit or sub unit
All FX-500 amplifiers can be used as either a main unit
or a sub unit. Just use a main cable or a sub cable to
distinguish the two. This reduces the costs of inventory
management.
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
The same part number
can be used as either
a main unit or sub unit!
Single copy & save operation
for all amplifiers
Retroreflective
Type
Reflective
Type
Others
Sub cable
Optical communication
window
Amplifiers
FX-501□
FX-502□
FX-500
series
Main cable (3-core)
CN-73-C□
Sub cable (1-core)
CN-71-C□
Main cable (4-core)
CN-74-C□
Sub cable (2-core)
CN-72-C□
FX-100
series
Main cable
Disconnection is possible without
moving the amplifier sideways
INDEX
74
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Type
Appearance
Emitting
element
Model No.
Standard
type
Fiber
Selection
Guide
Amplifiers Quick-connection cable is not supplied with FX-501(P) and FX-502(P). Please order it separately.
2-output type
Tough
Fiber
ORDER GUIDE
Output
FX-501
NPN open-collector transistor
FX-501P
PNP open-collector transistor
NPN open-collector transistor 2 outputs
Red LED
FX-502P
PNP open-collector transistor 2 outputs
FX-505-C2
NPN open-collector transistor 2 outputs,
analog output
FX-505P-C2
PNP open-collector transistor 2 outputs,
analog output
Threaded
Type
Square Head
Type
Quick-connection cables
Cylindrical
Type
For FX-501(P) Quick-connection cable is not supplied with the amplifier. Please order it separately.
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Type
Main cable
(3-core)
Sub cable
(1-core)
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
CN-73-C1
Description
Incorporated
(Switchable with Output 2)
Incorporated
Main cable
• CN-73-C□
Length: 1 m 3.281 ft
CN-73-C5
0.2 mm2 3-core cabtyre cable, with connector
Length: 2 m 6.562 ft on one end
Cable outer diameter: ø3.3 mm ø0.130 in
Length: 5 m 16.404 ft
CN-71-C1
Length: 1 m 3.281 ft
CN-71-C2
Length: 2 m 6.562 ft
CN-73-C2
CN-71-C5
Retroreflective
Type
Chemical / Oilresistant
Model No.
External input
–
FX-502
Cable type
New product
introduction
0.2 mm 1-core cabtyre cable, with connector
on one end
Cable outer diameter: ø3.3 mm ø0.130 in
Length: 5 m 16.404 ft Connectable to a main cable up to 15 cables.
2
Sub cable
• CN-71-C□
For FX-502(P) Quick-connection cable is not supplied with the amplifier. Please order it separately.
Type
Main cable
(4-core)
Model No.
CN-74-C1
CN-74-C2
CN-74-C5
Sub cable
(2-core)
CN-72-C1
CN-72-C2
CN-72-C5
Description
Main cable
• CN-74-C□
Length: 1 m 3.281 ft
0.2 mm2 4-core cabtyre cable, with connector
Length: 2 m 6.562 ft on one end
Cable outer diameter: ø3.3 mm ø0.130 in
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft 0.2 mm2 2-core cabtyre cable, with connector
on one end
Length: 2 m 6.562 ft
Cable outer diameter: ø3.3 mm ø0.130 in
Length: 5 m 16.404 ft Connectable to a main cable up to 15 cables.
Sub cable
• CN-72-C□
End plates End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade.
Fiber
Dimensions
Appearance
Model No.
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
MS-DIN-E
Description
When amplifiers are mounted in cascade, or when
an amplifier moves depending on the way it is
installed on a DIN rail, these end plates clamp
amplifiers into place on both sides. Make sure to
use end plates when cascading multiple amplifiers
together.
Two pcs. per set
75
OPTIONS
New product
introduction
Designation
Model No.
Amplifier
mounting bracket
MS-DIN-2
Description
Mounting bracket for amplifier
Amplifier mounting bracket
Tough
Fiber
• MS-DIN-2
Fiber
Selection
Guide
Model
Accessory
• FX-MB1 (Amplifier protection seal)
10 sets of 2 communication window
seals and 1 connector seal
Choose
by shape/
application
Communication
window seal
How to read
Model No.
Earlier models
comparison
table
Connector seal
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
76
New product
introduction
SPECIFICATIONS
Tough
Fiber
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Model No.
Fiber
Selection
Guide
Type
Item
Standard type
2-output type
Cable type (Analog output type)
NPN output
FX-501
FX-502
FX-505-C2
PNP output
FX-501P
FX-502P
FX-505P-C2
+10
12 to 24 V DC-15 % Ripple P-P 10 % or less
Supply voltage
Power consumption
Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage, excluding analog output of cable type)
ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage, excluding analog output of cable type)
Output
(2-output type and cable type:
Output 1, Output 2)
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 100 mA
• Maximum source current: 100 mA
(2-output type and cable type are 50 mA) (Note 2)
(2-output type and cable type are 50 mA) (Note 2)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (Note 3) (at maximum sink current)
• Residual voltage: 2 V or less (Note 3) (at maximum source current)
Output points
Fibers
Super
Quality
1 point
2 points
Output operation
Switchable either Light-ON or Dark-ON by L/D mode
Short-circuit protection
Incorporated
Threaded
Type
Response time
H-SP: 25 μs or less, FAST: 60 μs or less, STD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable
Square Head
Type
Analog output (Cable type only)
Output current: 4 to 20 mA approx. [H-SP, FAST, STD: At 0 to 4,000 digits, LONG: At 0 to 8,000 digits (Note 4)], Response time: 2 ms or
less, Zero point: Within 4 mA ±1 % F.S., Span: Within 16 mA ±5 % F.S., Linearity: Within ±3 % F.S., Load resistance: 0 to 250 Ω
External input
(2-output type only, switchable
with Output 2)
–
NPN non-contact input
• Signal condition
High: +8 V to +V DC or Open
Low: 0 to +1.2 V DC
(at 0.5 mA source current)
• Input impedance: 10 kΩ approx.
Possible external input function
–
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Incident light intensity display range
Timer function
Vacuumresistant
H-SP / FAST / STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999
Incorporated with variable OFF-delay /
ON-delay /One-shot / ON OFF-delay /
ON-delay • One-shot timer, switchable
either effective or ineffective
Heatresistant
Incorporated with variable OFF-delay / ON-delay /One-shot / ON OFF-delay /
ON-delay • One-shot timer, switchable either effective or ineffective
Incorporated with variable OFF-delay / ON-delay /One-shot timer, switchable either
effective or ineffective
Timer range “ms”: 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx.,
Timer range “sec.”: 0.5 s approx., 1 to 32 s approx., 1 s approx.,
Timer range “1/10 ms”: 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx., each output is set individually
Timer period
Liquid Leak /
Liquid Detection
Fiber
Options
Emission halt / Teaching (Full-auto, Limit, 2-point) / Logic operation setting / Copy
lock / Display adjustment / Data bank load / Data bank save, selectable
Sensitivity setting
Retroreflective
Type
Chemical / Oilresistant
Light emitting amount selection function
Incorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode]
Interference prevention function
Incorporated (Note 5), selectable either automatic interference prevention or different frequency
Hysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading
saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold tracking setting, etc.
Various settings
Protection
Semi-custom
fibers
IP40 (IEC)
-10 to +55 °C +14 to +131 °F [If 4 to 7 units are mounted in cascade: -10 to +50 °C +14 to +122 °F or if 8 to 16 units (cable type: 8 to 12 units)
are mounted in cascade: -10 to +45 °C +14 to +113 °F] (No dew condensation or icing allowed), Storage: -20 to +70 °C -4 to +158 °F
Ambient temperature
Emitting element (modulated)
Fiber
Dimensions
PNP non-contact input
• Signal condition
High: +4 V to +V DC
(at 3 mA sink current)
Low: 0 to +0.6 V DC or Open
• Input impedance: 10 kΩ approx.
Red LED (Peak emission wavelength: 643 nm 0.025 mil)
Material
Enclosure, Case cover: Polycarbonate, Switch: TPEE
Cable
–
0.2 mm2 6-core cabtyre cable, 2 m 6.562 ft long
Retroreflective
Type
Cable extension
–
Reflective
Type
Extension up to total 100 m 328.084 ft is
possible with 0.3 mm2, or more, cable.
(however, supply voltage 12 V DC)
Weight
Net weight: 15 g approx., Gross weight: 70 g approx.
Net weight: 60 g approx., Gross weight: 100 g approx.
Thru-beam
Type
Others
Amplifiers
FX-500
series
FX-100
series
FX-MB1 (Amplifier protection seal): 1 set
Accessory
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)
3) In case of using the quick-connection cable (cable length 5 m 16.404 ft) (optional).
4) If display adjustment was conducted, it is not in this range.
5) Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below.
Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units.
● Number
of sensor heads mountable closely (Unit: set)
Response time H-SP FAST STD LONG U-LG HYPR
IP-1
INDEX
0
2
4
8
8
12
77
I/O CIRCUIT AND WIRING DIAGRAMS
New product
introduction
FX-501
NPN output type
I/O circuit diagram
Load
(Black) Output
2
+
Fiber
Selection
Guide
+
12 to 24 V DC
+10
%
–
-15
-15
Blue (Note 1)
Note: The quick-connection sub cable does not have a brown and a blue
lead wire.
(Blue) 0 V (Note 1)
Internal circuit
Load
Black
12 to 24 V DC
+10
%
–
100 mA max. (Note 2)
3
Color code of quick-connection cable
Brown (Note 1)
(Brown) +V (Note 1)
1
Sensor circuit
Wiring diagram
Terminal No.
Color code of quick-connection cable
User’s circuit
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 50 mA max., if five amplifiers or more, are connected together.
Terminal arrangement diagram
Sensor circuit
100 mA max. (Note 2)
2
3
+
Fibers
3
0V
Super
Quality
–
(Black) Output
12 to 24 V DC
+10
%
–
-15
Note: The quick-connection sub cable does not have a brown and a blue
lead wire.
User’s circuit
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 50 mA max., if five amplifiers or more, are connected together.
Terminal arrangement diagram
1
+V
2
Output
3
0V
Sensor circuit
1
4
2
Color code of quick-connection cable
(Brown) +V (Note 1)
(White) Output 2 / External input
50 mA max. (Note 2)
(Black) Output 1
+
–
External
input
-15
Blue (Note 1)
+
User’s circuit
+V
2
Output 1
3
0V
4
Sensor circuit
1
2
4
3
Internal circuit
Brown (Note 1)
(Brown) +V (Note 1)
50 mA max. (Note 2)
(Black) Output 1
50 mA max. (Note 2)
(White) Output 2 / External input
External
input
+
–
Black
12 to 24 V DC
+10
%
-15
Load Load
(Blue) 0 V (Note 1)
User’s circuit
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 25 mA max., if five amplifiers or more, are connected together.
White
Blue Load Load
(Note 1)
External
input
+
12 to 24 V DC
+10
–
%
-15
Note: The quick-connection sub cable does not have a brown and a blue
lead wire.
Terminal arrangement diagram
1
+V
2
Output 1
3
0V
Fiber
Options
Fiber
Dimensions
Color code of quick-connection cable
Wiring diagram
Color code of quick-connection cable
Vacuumresistant
Output 2 / External input
PNP output type
Terminal No.
Heatresistant
Semi-custom
fibers
FX-502P
I/O circuit diagram
Chemical / Oilresistant
-15
External
input
Terminal arrangement diagram
1
Narrow
Beam
12 to 24 V DC
+10
%
–
Note: The quick-connection sub cable does not have a brown and a blue
lead wire.
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 25 mA max., if five amplifiers or more, are connected together.
Small
Spot
Liquid Leak /
Liquid Detection
Load Load
Black
12 to 24 V DC
+10
%
(Blue) 0 V (Note 1)
Internal circuit
Color code of quick-connection cable
White
Load Load
Flat
Type
Retroreflective
Type
Brown (Note 1)
50 mA max. (Note 2)
3
Wiring diagram
Sleeve
Wide
Beam
NPN output type
Terminal No.
Square Head
Type
Convergent
Reflective
Type
FX-502
I/O circuit diagram
Threaded
Type
Cylindrical
Type
+
Load
Blue (Note 1)
-15
Load
(Blue) 0 V (Note 1)
Internal circuit
Color code of quick-connection cable
Black
12 to 24 V DC
+10
%
Earlier models
comparison
table
Output
Brown (Note 1)
(Brown) +V (Note 1)
1
How to read
Model No.
2
Wiring diagram
Color code of quick-connection cable
Choose
by shape/
application
+V
PNP output type
Terminal No.
Model
1
FX-501P
I/O circuit diagram
Tough
Fiber
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
4
Output 2 / External input
INDEX
78
I/O CIRCUIT AND WIRING DIAGRAMS
New product
introduction
Tough
Fiber
FX-505-C2
NPN output type
I/O circuit diagram
Fiber
Selection
Guide
Choose
by shape/
application
How to read
Model No
(Pink) External input
Sensor circuit
Model
Wiring diagram
Color code
(Brown) +V
Brown
Load
Load
(Black) Output 1
+
–
(White) Output 2
Black
12 to 24 V DC
10
%
15
+
Pink
(Gray) Analog output (4 to 20 mA)
Internal circuit
Load
White
(Blue) 0 V
Earlier models
comparison
table
Load
–
12 to 24 V DC
10
%
15
Blue
Load (0 to 250 Ω)
Load (0 to 250 Ω)
Gray
User’s circuit
Fibers
Super
Quality
Threaded
Type
Square Head
Type
FX-505P-C2
I/O circuit diagram
Cylindrical
Type
Wide
Beam
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
+
(White) Output 2
Load
(Pink) External input
(Blue) 0 V
Narrow
Beam
Convergent
Reflective
Type
Color code
Brown
(Black) Output 1
Sensor circuit
Small
Spot
Wiring diagram
(Brown) +V
Sleeve
Flat
Type
PNP output type
User’s circuit
12 to 24 V DC
10
%
15
Pink
Black
+
White
Load
(Gray) Analog output (4 to 20 mA)
Internal circuit
–
Load (0 to 250 Ω)
Blue
Gray
Load
Load
–
12 to 24 V DC
10
%
15
Load (0 to 250 Ω)
79
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Tough
Fiber
Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Left
Center
Right
Operating point ℓ (mm in)
L
Fiber
head
H-SP
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
FT-42W
300
11.811
3,000
118.110
2,000
78.740
Fiber
head
STD
ℓ
1,000
39.370
L
Fiber
head
H-SP
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Left
Center
Right
Operating point ℓ (mm in)
1,000
0
1,000
39.370
39.370
Left
Center
Right
Operating point ℓ (mm in)
1,500
59.055
1,000
39.370
Fiber
head
H-SP
ℓ
L
Fiber
head
500
19.685
1,000
0
1,000
39.370
39.370
Left
Center
Right
Operating point ℓ (mm in)
4,000
157.480
2,000
78.740
STD
Fiber
head
H-SP
ℓ
1,000
39.370
L
Fiber
head
0
400 300 200 100 0 100 200 300 400
15.748 11.811 7.874 3.937
3.937 7.874 11.811 15.748
Left
Center
Right
Operating point ℓ (mm in)
FTA162
3,000
118.110
2,000
78.740
1,000
39.370
500
19.685
Fiber
head
H-SP
8mm ℓ
0.315in
L
Fiber
head
0
400 300 200 100
0 100 200 300 400
15.748 11.811 7.874 3.937
3.937 7.874 11.811 15.748
Down
Center
Up
Operating point ℓ (mm in)
L
Fiber
head
H-SP
1,000
0
1,000
39.370
39.370
Left
Center
Right
Operating point ℓ (mm in)
FT-45X
Choose
by shape/
application
How to read
Model No.
STD
Fiber
head
ℓ
H-SP
400
200
0
200
400
15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
600
23.622
Fibers
Super
Quality
Thru-beam type
FTA186
Threaded
Type
Square Head
Type
Cylindrical
Type
HYPR
2,500
98.425
Sleeve
2,000
78.740
Flat
Type
1,500
59.055
STD
1,000
39.370
H-SP
Fiber
head
ℓ
L
Fiber
head
500
19.685
0
2,000
78.740
Small
Spot
Narrow
Beam
Wide
Beam
2,000 Convergent
78.740 Reflective
Type
1,000
0
1,000
39.370
39.370
Left
Center
Right
Operating point ℓ (mm in)
Retroreflective
Type
Chemical / Oilresistant
Thru-beam type
FTA221
Heatresistant
FTA185
500
19.685
Earlier models
comparison
table
L
Fiber
head
FT-42S
2,000
78.740
Model
HYPR
Vacuumresistant
STD
Liquid Leak /
Liquid Detection
1,000
39.370
Fiber
head
ℓ
H-SP
Fiber
Options
L
Fiber
head
0
1,500
59.055
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Left
Center
Right
Operating point ℓ (mm in)
Semi-custom
fibers
1,500
59.055
FT-A11W
Thru-beam type
FTA192
Horizontal direction
4,000
157.480
STD
Setting distance L (mm in)
ℓ
2,000
78.740
HYPR
1,000
39.370
Fiber
head
Fiber
Selection
Guide
HYPR
500
19.685
3,000
118.110
STD
Thru-beam type
1,000
39.370
0
600
23.622
HYPR
0
2,000
78.740
4,000
157.480
3,000
118.110
3,500
137.795
3,000
118.110
2,500
98.425
2,000
78.740
1,500
59.055
HYPR
STD
L
Fiber
head
Thru-beam type
FTA219
1,500
59.055
Horizontal direction
FTA179
HYPR
FT-42
Thru-beam type
FTA224
2,000
78.740
ℓ
0
800 600 400 200 0 200 400 600 800
31.496 23.622 15.748 7.874
7.874 15.748 23.622 31.496
Left
Center
Right
Operating point ℓ (mm in)
2,000
78.740
Thru-beam type
FTA183
Vertical direction
Setting distance L (mm in)
Setting distance L (mm in)
FT-A11
L
Fiber
head
H-SP
0
2,000
78.740
1,500
59.055
ℓ
1,000
39.370
2,500
98.425
HYPR
Fiber
head
STD
STD
Fiber
head
H-SP
HYPR
2,000
78.740
FT-43
500
19.685
600
23.622
3,000
118.110
0
2,000
78.740
Thru-beam type
FTA180
4,000
157.480
0
1,500
59.055
Setting distance L (mm in)
Setting distance L (mm in)
Fiber
head
ℓ
STD
400
15.748
1,000
39.370
Thru-beam type
FTA225
4,000
157.480
800
31.496
L
Fiber
head
400
200
0
200
400
15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
FT-40
HYPR
1,000
39.370
0
300
11.811
0
600
23.622
1,500
59.055
FTA187
600
23.622
ℓ
H-SP
Thru-beam type
1,200
47.244
200
7.874
STD
500
19.685
HYPR
Setting distance L (mm in)
L
Fiber
head
FT-31W
Setting distance L (mm in)
Fiber
head
ℓ
5,000
196.850
Fiber
head
1,500
59.055
3,000
118.110
Vertical direction
4,000
157.480
HYPR
STD
H-SP
2,000
78.740
Fiber
head
ℓ
1,000
39.370
0
600
23.622
L
Fiber
head
400
200
0
200
400
15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
600
23.622
Setting distance L (mm in)
H-SP
Setting distance L (mm in)
10,000
393.700
1,000
39.370
Setting distance L (mm in)
STD
HYPR
FT-31S
Thru-beam type
1,500
59.055
Setting distance L (mm in)
15,000
590.550
Setting distance L (mm in)
HYPR
FT-31
Thru-beam type
1,500
59.055
Setting distance L (mm in)
Setting distance L (mm in)
20,000
787.400
0
1,500
59.055
FT-30
Thru-beam type
Setting distance L (mm in)
FT-140
3,000
118.110
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
HYPR
Reflective
Type
STD
Others
H-SP
2,000
78.740
Fiber
head
8mm ℓ
0.315in
1,000
39.370
0
600
23.622
L
Amplifiers
Fiber
head
FX-500
series
400
200
0
200
400
15.748 7.874
7.874 15.748
Down
Center
Up
Operating point ℓ (mm in)
600 FX-100
23.622 series
INDEX
FTA162
FTA217
FTA217
80
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
Tough
Fiber
(Models with same sensing characteristics are grouped together.)
FT-A32
Fiber
Selection
Guide
Vertical direction
Horizontal direction
Vertical direction
4,000
157.480
4,000
157.480
4,000
157.480
4,000
157.480
L
Fiber
head
Square Head
Type
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
2,500
98.425
Setting distance L (mm in)
Retroreflective
Type
Heatresistant
L
Fiber
head
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Left
Center
Right
Operating point ℓ (mm in)
4,000
157.480
Setting distance L (mm in)
ℓ
L
2,000
78.940
HYPR
Fiber
head
STD
1,000
39.370
Fiber
Dimensions
Thru-beam
Type
H-SP
1,500
59.055
STD
500
19.685
H-SP
0
1,500
59.055
ℓ
L
Fiber
head
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Down
Center
Up
Operating point ℓ (mm in)
STD
Fiber
head
ℓ
L
Fiber
head
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
400
15.748
20
0.787
ℓ
Fiber
head
20
10
0
10
20
0.787 0.394
0.394 0.787
Left
Center
Right
Operating point ℓ (mm in)
2,000
78.740
STD
H-SP
ℓ
STD
150
5.906
100
3.937
50
1.969
150
5.906
Fiber
head
ℓ
L
Fiber
head
H-SP
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
150
5.906
FTA223
STD
1,000
39.370
Fiber
head
500
19.685
ℓ
H-SP
L
Fiber
head
1,000
0
1,000
39.370
39.370
Left
Center
Right
Operating point ℓ (mm in)
FT-H20W-M1
2,000
78.740
FT-H30-M1V-S Thru-beam type
Thru-beam type
Vertical direction
HYPR
L
STD
H-SP
1,500
59.055
400
15.748
HYPR
1,000
39.370
500
19.685
0
200
0
200
7.874
7.874
Down
Center
Up
Operating point ℓ (mm in)
200
7.874
2,000
78.740
Fiber head
0
400
15.748
HYPR
250
9.843
0
Horizontal direction
HYPR
1,000
39.370
Thru-beam type
FTA218
1,500
59.055
0
2,000
78.740
800
31.496
Thru-beam type
2,000
78.740
300
11.811
HYPR
L
Fiber
head
400
0
400
15.748
15.748
Left
Center
Right
Operating point ℓ (mm in)
200
100
0
100
200
7.874 3.937
3.937 7.874
Down
Center
Up
Operating point ℓ (mm in)
FT-E23
30
1.181
L
Fiber
head
Thru-beam type
FTA222
Fiber
head
800
31.496
Fiber
head
L
H-SP
2,000
78.740
500
19.685
19mm ℓ
0.748in
300
11.811
STD
FT-H20-M1
HYPR
300
11.811
HYPR
30
1.181
30
1.181
Fiber
head
1,000
39.370
Thru-beam type
FTA218
FT-H20-J20-S FT-H20-J30-S Thru-beam
FTA215
type
FT-H20-J50-S
1,000
39.370
2,000
78.740
300
11.811
40
1.575
0
1,500
59.055
Vertical direction
HYPR
H-SP
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
50
1.969
10
0.394
H-SP
0
FT-E13
Fiber head
0
400
15.748
INDEX
36mm
1.417in
ℓ
Setting distance L (mm in)
FX-100
series
Fiber
head
1,500
59.055
1,000
39.370
Horizontal direction
1,000
39.370
Fiber
head
60
2.362
1,000
39.370
FT-H20-VJ50-S FT-H20-VJ80-S
Setting distance L (mm in)
FX-500
series
300
11.811
HYPR
Others
Amplifiers
1,000
39.370
3,000
118.110
0
0
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
2,000
78.740
L
300
11.811
2,000
78.740
1,500
59.055
Fiber
head
3,000
118.110
0
1,000
39.370
Reflective
Type
ℓ
H-SP
500
19.685
Fiber
head
Thru-beam type
FTA215
Liquid Leak /
Liquid Detection
Retroreflective
Type
2,500
98.425
STD
1,000
39.370
ℓ
Vertical direction
FT-H13-FM2
Vacuumresistant
Semi-custom
fibers
200
100
0
100
200
7.874 3.937
3.937 7.874
Down
Center
Up
Operating point ℓ (mm in)
H-SP
2,000
78.740
Thru-beam type
FTA216
2,000
78.740
1,500
59.055
L
Fiber
head
300
11.811
300
11.811
HYPR
0
1,500
59.055
Chemical / Oilresistant
Fiber
Options
19mm ℓ
0.748in
1,000
39.370
Setting distance L (mm in)
Convergent
Reflective
Type
Fiber
head
0
FTA216
Horizontal direction
Sleeve
Wide
Beam
2,000
78.740
FT-AL05
Cylindrical
Type
Narrow
Beam
HYPR
STD
Fiber
head
Setting distance L (mm in)
300
11.811
H-SP
3,000
118.110
Setting distance L (mm in)
0
STD
Setting distance L (mm in)
ℓ
1,000
39.370
3,000
118.110
Setting distance L (mm in)
Fiber
head
Threaded
Type
Small
Spot
HYPR
800
31.496
Setting distance L (mm in)
2,000
78.740
Super
Quality
Flat
Type
HYPR
Setting distance L (mm in)
H-SP
Setting distance L (mm in)
STD
Setting distance L (mm in)
Fibers
3,000
118.110
Setting distance L (mm in)
Earlier models
comparison
table
HYPR
STD
Setting distance L (mm in)
How to read
Model No
Thru-beam type
Horizontal direction
Model
Choose
by shape/
application
FT-A32W
Thru-beam type
STD
H-SP
ℓ
Fiber
head
L
Fiber
head
400
0
400
15.748
15.748
Left
Center
Right
Operating point ℓ (mm in)
800
31.496
1,000
39.370
STD
500
19.685
H-SP
0
800
31.496
Fiber
head
ℓ
L
Fiber
head
400
0
400
15.748
15.748
Left
Center
Right
Operating point ℓ (mm in)
800
31.496
81
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
Tough
Fiber
(Models with same sensing characteristics are grouped together.)
FT-H35-M2
FT-H35-M2S6
FT-HL80Y
Thru-beam type
4,000
157.480
4,000
157.480
Thru-beam type
Fiber
Selection
Guide
HYPR
Model
1,500
59.055
HYPR
1,000
39.370
STD
500
19.685
0
1,000
39.370
Fiber
head
ℓ
H-SP
L
Fiber
head
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
3,000
118.110
2,000
78.740
STD
H-SP
1,000
39.370
0
800
31.496
1,000
39.370
Setting distance L (mm in)
HYPR
Setting distance L (mm in)
Setting distance L (mm in)
2,000
78.740
FT-KS40
Thru-beam type
Fiber
head
ℓ
L
Fiber
head
400
0
400
15.748
15.748
Left
Center
Right
Operating point ℓ (mm in)
FT-KV26
3,000
118.110
Choose
by shape/
application
STD
2,000
78.740
How to read
Model No.
Fiber
head
H-SP
Earlier models
comparison
table
ℓ
1,000
39.370
L
Fiber
head
0
800
31.496
100
3.937
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
FT-KV40
Thru-beam type
Fibers
100
3.937
Super
Quality
FTA208
Thru-beam type
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
3,000
118.110
3,000
118.110
4,000
157.480
4,000
157.480
1,500
59.055
STD
1,000
39.370
ℓ
H-SP
Fiber
head
L
Fiber
head
500
19.685
2,000
78.740
1,500
59.055
1,000
39.370
STD
Fiber
head
H-SP
ℓ
500
19.685
L
Fiber
head
3,000
118.110
STD
2,000
78.740
H-SP
0
100
3.937
80 60 40 20
0
20 40 60 80
3.150 2.362 1.575 0.787
0.787 1.575 2.362 3.150
Down
Center
Up
Operating point ℓ (mm in)
80 60 40 20
0
20 40 60 80
3.150 2.362 1.575 0.787
0.787 1.575 2.362 3.150
Left
Center
Right
Operating point ℓ (mm in)
FT-KV40W FTA209
Vertical direction
4,000
157.480
4,000
157.480
HYPR
Fiber
head
L
Fiber
head
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
FT-L80Y
Thru-beam type
FTA209
Horizontal direction
ℓ
1,000
39.370
0
0
HYPR
Setting distance L (mm in)
Setting distance L (mm in)
Setting distance L (mm in)
2,000
78.740
HYPR
2,500
98.425
Setting distance L (mm in)
HYPR
2,500
98.425
STD
2,000
78.740
H-SP
Flat
Type
Small
Spot
ℓ
L
Fiber
head
50
0
50
1.969
1.969
Down
Center
Up
Operating point ℓ (mm in)
FT-R40
Thru-beam type
FTA205
Narrow
Beam
Fiber
head
0
4,000
157.480
HYPR
Sleeve
HYPR
3,000
118.110
100
3.937
4,000
157.480
Square Head
Type
Cylindrical
Type
1,000
39.370
100
3.937
Threaded
Type
100
3.937
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Thru-beam type
FTA205
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
HYPR
1,000
39.370
0
100
3.937
Fiber
head
L
Fiber
head
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
FT-R41W
H-SP
Fiber
head
1,000
39.370
0
100
3.937
100
3.937
ℓ
L
Fiber
head
50
0
50
1.969
1.969
Down
Center
Up
Operating point ℓ (mm in)
3,500
137.795
3,000
118.110
2,500
98.425
2,000
78.740
1,500
59.055
3,500
137.795
3,000
118.110
2,500
98.425
2,000
78.740
1,500
59.055
1,000
39.370
500
19.685
0 1,500
59.055
FTA206
HYPR
Fiber
head
STD
ℓ
H-SP
L
Fiber
head
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Left
Center
Right
Operating point ℓ (mm in)
FTA193
1,500
59.055
Setting distance L (mm in)
Setting distance L (mm in)
Horizontal direction
Thru-beam type
FTA206
Vertical direction
1,000
39.370
500
19.685
0 1,500
59.055
0
800
31.496
ℓ
H-SP
L
Fiber
head
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Down
Center
Up
Operating point ℓ (mm in)
FTA193
1,500
59.055
Fiber
head
ℓ
L
Fiber
head
400
0
400
15.748
15.748
Left
Center
Right
Operating point ℓ (mm in)
3,000
118.110
STD
1,000
39.370
2,000
78.740
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Left
Center
Right
Operating point ℓ (mm in)
4,000
157.480
STD
Fiber
head
H-SP
ℓ
L
Fiber
head
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
FTA194
1,000
39.370
3,000
118.110
2,000
78.740
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
HYPR
Others
STD
Fiber
head
H-SP
ℓ
1,000
39.370
0
1,000
39.370
Semi-custom
fibers
1,500
59.055
FTA184
Vertical direction
HYPR
1,000
39.370
0
1,000
39.370
L
Fiber
head
Thru-beam type
Horizontal direction
3,000
118.110
Fiber
head
ℓ
H-SP
0
1,500
59.055
800
31.496
Fiber
Options
2,000
78.740
FT-R42W
HYPR
STD
H-SP
1,000
39.370
4,000
157.480
Fiber
head
STD
2,000
78.740
100
3.937
Setting distance L (mm in)
ℓ
2,000
78.740
3,000
118.110
Setting distance L (mm in)
H-SP
STD
Setting distance L (mm in)
2,000
78.740
3,000
118.110
Setting distance L (mm in)
STD
Setting distance L (mm in)
Setting distance L (mm in)
HYPR
3,000
118.110
500
0
500
19.685
19.685
Down
Center
Up
Operating point ℓ (mm in)
FTA194
L
Fiber
head
Amplifiers
FX-500
series
FX-100
series
1,000
39.370
INDEX
82
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
3,000
118.110
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Setting distance L (mm in)
Small
Spot
Chemical / Oilresistant
Heatresistant
4,000
157.480
Semi-custom
fibers
Setting distance L (mm in)
Liquid Leak /
Liquid Detection
Fiber
Options
ℓ
L
H-SP
Fiber
head
1,000
0
1,000
39.370
39.370
Left
Center
Right
Operating point ℓ (mm in)
2,000
78.740
FX-500
series
FX-100
series
Setting distance L (mm in)
Reflective
Type
500
19.685
Setting distance L (mm in)
Fiber
head
400
200
0
200
400
15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
STD
ℓ
H-SP
Fiber
head
L
Fiber
head
STD
1,000
39.370
Fiber
head
ℓ
L
Fiber
head
H-SP
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Left
Center
Right
Operating point ℓ (mm in)
0
800 600 400 200 0 200 400 600 800
31.496 23.622 15.748 7.874
7.874 15.748 23.622 31.496
Left
Center
Right
Operating point ℓ (mm in)
H-SP
Fiber
head
FT-S32
STD
Fiber
head
ℓ
L
H-SP
Fiber
head
0
800 600 400 200 0 200 400 600 800
31.496 23.622 15.748 7.874
7.874 15.748 23.622 31.496
Down
Center
Up
Operating point ℓ (mm in)
FTA226
Thru-beam type
HYPR
800
31.496
600
23.622
Fiber
head
400
15.748
200
7.874
0
300
11.811
STD
Fiber
head
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
FTA182
STD
H-SP
Fiber
head
ℓ
L
Fiber
head
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
1,000
39.370
FT-V24W
Thru-beam type
FTA177
Horizontal direction
Vertical direction
400
15.748
HYPR
HYPR
300
11.811
STD
200
7.874
ℓ
H-SP
Fiber
head
L
Fiber
head
0
200
7.874
100
0
100
3.937
3.937
Left
Center
Right
Operating point ℓ (mm in)
200
7.874
200
7.874
100
3.937
STD
L
H-SP
Fiber
head
0
200
7.874
FTA190
FTA188
Fiber
head
ℓ
100
0
100
3.937
3.937
Down
Center
Up
Operating point ℓ (mm in)
INDEX
FTA190
300
11.811
HYPR
1,000
39.370
100
3.937
ℓ
L
H-SP
Thru-beam type
300
11.811
1,000
39.370
1,000
39.370
1,000
39.370
FTA220
2,000
78.740
0
1,000
39.370
L
Fiber
head
500
0
500
19.685
19.685
Down
Center
Up
Operating point ℓ (mm in)
FT-S21W
0
800 600 400 200 0 200 400 600 800
31.496 23.622 15.748 7.874
7.874 15.748 23.622 31.496
Left
Center
Right
Operating point ℓ (mm in)
400
15.748
HYPR
ℓ
L
1,500
59.055
1,500
59.055
500
19.685
STD
3,000
118.110
2,000
78.740
HYPR
500
19.685
ℓ
H-SP
1,200
47.244
Fiber
head
Fiber
head
STD
1,000
39.370
HYPR
4,000
157.480
2,000
78.740
2,000
78.740
0
1,000
39.370
FTA226
Thru-beam type
HYPR
3,000
118.110
1,000
39.370
1,000
39.370
Thru-beam type
FTA227
HYPR
L
Fiber
head
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
FT-S21
600
23.622
Thru-beam type
FTA181
Vertical direction
1,500
59.055
1,000
39.370
L
0
1,500
59.055
2,000
78.740
FT-V23
FTA226
Horizontal direction
Amplifiers
Fiber
head
STD
Retroreflective
Type
Others
ℓ
4,000
157.480
1,000
39.370
0
2,000
78.740
Fiber
head
3,000
118.110
2,000
78.740
0
1,000
39.370
1,500
59.055
500
19.685
H-SP
ℓ
H-SP
FTA227
Thru-beam type
STD
Fiber
head
STD
1,000
39.370
HYPR
FT-S31W
Thru-beam type
FTA178
2,000
78.740
1,200
47.244
1,000
39.370
0
600
23.622
HYPR
L
Fiber
head
800
400
0
400
800
31.496 15.748
15.748 31.496
Down
Center
Up
Operating point ℓ (mm in)
FT-S20
150
5.906
3,000
118.110
Fiber
Dimensions
Thru-beam
Type
Fiber
head
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
FT-S30
Vacuumresistant
Fiber
head
L
H-SP
ℓ
1,500
59.055
ℓ
0
150
5.906
0
1,200
47.244
FTA227
Thru-beam type
STD
Fiber
head
H-SP
HYPR
200
7.874
Retroreflective
Type
1,000
39.370
1,200
47.244
300
11.811
100
3.937
STD
4,000
157.480
HYPR
3,000
118.110
Setting distance L (mm in)
400
15.748
Sleeve
Flat
Type
800
400
0
400
800
31.496 15.748
15.748 31.496
Left
Center
Right
Operating point ℓ (mm in)
FT-S11
Cylindrical
Type
L
Fiber
head
HYPR
Setting distance L (mm in)
Threaded
Type
Square Head
Type
ℓ
H-SP
0
1,200
47.244
Super
Quality
Setting distance L (mm in)
1,000
39.370
Fiber
head
Setting distance L (mm in)
Fibers
STD
4,000
157.480
2,000
78.740
Setting distance L (mm in)
Earlier models
comparison
table
2,000
78.740
Setting distance L (mm in)
How to read
Model No
Setting distance L (mm in)
Choose
by shape/
application
HYPR
Vertical direction
Horizontal direction
Setting distance L (mm in)
Vertical direction
3,000
118.110
Thru-beam type
Setting distance L (mm in)
Horizontal direction
Model
FT-R60Y
Thru-beam type
Setting distance L (mm in)
FT-R44Y
Fiber
Selection
Guide
Setting distance L (mm in)
Tough
Fiber
FTA188
200
7.874
83
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Tough
Fiber
Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
1,000
39.370
400
15.748
ℓ
L
Fiber
head
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
FT-V40
Setting distance L (mm in)
Setting distance L (mm in)
300
11.811
Fiber
head
ℓ
L
Fiber
head
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
300
11.811
ℓ
Fiber
head
400
200
0
200
400
15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
FT-Z30
Setting distance L (mm in)
2,000
78.740
Fiber
head
200
100
0
100
200
7.874 3.937
3.937 7.874
Down
Center
Up
Operating point ℓ (mm in)
HYPR
3,000
118.110
H-SP
ℓ
2.2mm
0.087in
Fiber
head
L
Fiber
head
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
FTA198
1,000
39.370
2,000
78.740
STD
2,000
78.740
Fiber head
ℓ
H-SP
L
Fiber head
400
0
400
15.748
15.748
Left
Center
Right
Operating point ℓ (mm in)
0
1,000
39.370
Fibers
1,000
39.370
3,000
118.110
2,000
78.740
Threaded
Type
500
19.685
L
H-SP
Fiber
head
Flat
Type
Small
Spot
STD
Narrow
Beam
Wide
Beam
H-SP
Fiber head
ℓ
Convergent
Reflective
Type
L
Fiber head
400
0
400
15.748
15.748
Down
Center
Up
Operating point ℓ (mm in)
800
31.496
STD
FTA198
Chemical / Oilresistant
Vacuumresistant
STD
Fiber
head
1.2mm
0.047in
H-SP
ℓ
Fiber
head
L
Fiber
head
Fiber
head
Fiber
Dimensions
Thru-beam
Type
FT-Z30E FTA294
Thru-beam type
Vertical direction
3,000
118.110
2,000
78.740
STD
Fiber
head
H-SP
ℓ
1,000
39.370
300
11.811
4,000
157.480
HYPR
L
Fiber
head
0
1,000
39.370
Semi-custom
fibers
L
400 300 200 100 0 100 200 300 400
15.748 11.811 7.874 3.937
3.937 7.874 11.811 15.748
Down
Center
Up
Operating point ℓ (mm in)
4,000
157.480
500
0
500
19.685
19.685
Down
Center
Up
Operating point ℓ (mm in)
Retroreflective
Type
Fiber
Options
0
HYPR
5.5mm
0.217in
Cylindrical
Type
Liquid Leak /
Liquid Detection
Horizontal direction
H-SP
Square Head
Type
Sleeve
HYPR
1,000
39.370
0
800
31.496
800
31.496
Super
Quality
HYPR
1,000
39.370
Fiber
head
ℓ
ℓ
1,000
39.370
500
0
500
19.685
19.685
Down
Center
Up
Operating point ℓ (mm in)
1,500
59.055
Vertical direction
STD
L
Fiber
head
Thru-beam type
400 300 200 100 0 100 200 300 400
15.748 11.811 7.874 3.937
3.937 7.874 11.811 15.748
Left
Center
Right
Operating point ℓ (mm in)
4,000
157.480
4,000
157.480
Earlier models
comparison
table
Heatresistant
FTA294
Thru-beam type
HYPR
ℓ
H-SP
Vertical direction
STD
0
800
31.496
300
11.811
Fiber
head
FTA191
Thru-beam type
HYPR
FTA207
0
FTA203
1,000
39.370
0
1,000
39.370
L
0
1,000
39.370
1,000
39.370
3,000
118.110
1,000
39.370
500
19.685
FTA191
2,000
78.740
600
23.622
Horizontal direction
3,000
118.110
FT-V80Y
2,000
78.740
500
19.685
L
200
7.874
4,000
157.480
ℓ
1,000
39.370
Fiber
head
STD
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
Vertical direction
Setting distance L (mm in)
600
23.622
600
23.622
Fiber
head
1,500
59.055
800
31.496
L
Fiber
head
Horizontal direction
Setting distance L (mm in)
Setting distance L (mm in)
1,000
39.370
H-SP
FT-Z20W
ℓ
STD
1,000
39.370
Fiber
head
H-SP
4,000
157.480
1,000
39.370
0
STD
Horizontal direction
STD
2,000
78.740
300
11.811
HYPR
H-SP
0
1,000
39.370
Choose
by shape/
application
How to read
Model No.
1,500
59.055
1,000
39.370
500
19.685
Model
HYPR
2,000
78.740
1,500
59.055
300
11.811
HYPR
3,000
118.110
Thru-beam type
FT-Z20HBWFTA207
0
200
100
0
100
200
7.874 3.937
3.937 7.874
Down
Center
Up
Operating point ℓ (mm in)
4,000
157.480
0
400
15.748
Fiber
head
Vertical direction
H-SP
1,200
47.244
L
FTA189
Thru-beam type
1,000
39.370
300
11.811
ℓ
H-SP
FTA189
STD
2,000
78.740
Fiber
head
0
HYPR
3,000
118.110
200
7.874
300
11.811
Horizontal direction
4,000
157.480
400
15.748
Setting distance L (mm in)
300
11.811
H-SP
STD
2,500
98.425
HYPR
2,000
78.740
Setting distance L (mm in)
200
7.874
0
Fiber
head
600
23.622
Setting distance L (mm in)
STD
Setting distance L (mm in)
600
23.622
800
31.496
Setting distance L (mm in)
Setting distance L (mm in)
800
31.496
2,500
98.425
HYPR
Fiber
Selection
Guide
Vertical direction
Horizontal direction
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
FTA163
300
11.811
Setting distance L (mm in)
HYPR
Thru-beam type
Setting distance L (mm in)
Vertical direction
Horizontal direction
1,000
39.370
FT-V30
Thru-beam type
Setting distance L (mm in)
FT-V25
3,000
118.110
2,000
78.740
Reflective
Type
Others
HYPR
STD
Amplifiers
FX-500
series
Fiber
ℓ head
H-SP
1,000
39.370
FX-100
series
L
5.5mm
0.217in
Fiber
head
0
300
11.811
Retroreflective
Type
200
100
0
100
200
7.874 3.937
3.937 7.874
Down
Center
Up
Operating point ℓ (mm in)
FTA163
300
11.811
INDEX
84
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
INDEX
L
Fiber
head
200
0
200
7.874
7.874
Down
Center
Up
Operating point ℓ (mm in)
3,000
118.110
STD
Fiber
head
ℓ
L
H-SP
Fiber
head
STD
Fiber
head
1.2mm
0.047in
ℓ
H-SP
L
Fiber
head
Setting distance L (mm in)
STD
Fiber
head
H-SP
400
15.748
ℓ
L
5.5mm
0.217in
Fiber
head
200
0
200
7.874
7.874
Down
Center
Up
Operating point ℓ (mm in)
400
15.748
Thru-beam type
FTA201
Vertical direction
4,000
157.480
3,000
118.110
H-SP
ℓ
2.2mm
0.087in
Fiber
head
L
Fiber
head
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
2,000
78.740
HYPR
STD
Fiber
head
H-SP
ℓ
1,000
39.370
0
1,000
39.370
1,000
39.370
L
5.5mm
0.217in
Fiber
head
500
0
500
19.685
19.685
Down
Center
Up
Operating point ℓ (mm in)
1,000
39.370
Thru-beam type
FT-Z40HBWFTA199
Thru-beam type
FT-Z802Y FTA199
4,000
157.480
4,000
157.480
HYPR
HYPR
3,000
118.110
3,000
118.110
2,000
78.740
1,000
39.370
0
STD
1,000
39.370
HYPR
1,000
39.370
400
15.748
HYPR
2,000
78.740
0
1,000
39.370
400
15.748
HYPR
2,000
78.740
FT-Z30W FTA201
Thru-beam type
FTA202
HYPR
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
3,000
118.110
Setting distance L (mm in)
ℓ
5.5mm
0.217in
FTA202
0
800 600 400 200 0 200 400 600 800
31.496 23.622 15.748 7.874
7.874 15.748 23.622 31.496
Left
Center
Right
Operating point ℓ (mm in)
2,000
78.740
STD
1,000
39.370
0
1,500
59.055
0
800 600 400 200 0 200 400 600 800
31.496 23.622 15.748 7.874
7.874 15.748 23.622 31.496
Down
Center
Up
Operating point ℓ (mm in)
Fiber
head
ℓ
H-SP
L
Fiber
head
1,000
500
0
500
1,000
39.370 19.685
19.685 39.370
Left
Center
Right
Operating point ℓ (mm in)
2,000
78.740
H-SP
Fiber
head
ℓ
1,000
39.370
0
800
31.496
1,500
59.055
STD
L
Fiber
head
400
0
400
15.748
15.748
Left
Center
Right
Operating point ℓ (mm in)
800
31.496
Retroreflective type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
FR-KZ22E
FTA295
Retroreflective type
FTA295
Vertical direction
Horizontal direction
Setting distance L (mm in)
FX-100
series
0
400
15.748
400
15.748
3,000
118.110
600
23.622
FX-500
series
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
1,000
39.370
4,000
157.480
Reflective
Type
Amplifiers
L
Fiber
head
Vertical direction
1,000
39.370
400
15.748
3,000
118.110
H-SP
4,000
157.480
Thru-beam
Type
Others
ℓ
1,000
39.370
2,000
78.740
0
L
Fiber
head
4,000
157.480
Fiber
head
2,000
78.740
ℓ
Horizontal direction
STD
Horizontal direction
Fiber
Dimensions
Retroreflective
Type
Fiber
head
H-SP
Fiber
head
H-SP
1,000
39.370
400
15.748
HYPR
3,000
118.110
STD
FT-Z40W
Setting distance L (mm in)
Semi-custom
fibers
200
0
200
7.874
7.874
Down
Center
Up
Operating point ℓ (mm in)
STD
2,000
78.740
FTA200
Thru-beam type
HYPR
2,000
78.740
0
400
15.748
Heatresistant
Fiber
Options
400
15.748
4,000
157.480
Chemical / Oilresistant
Liquid Leak /
Liquid Detection
0
400
15.748
Vertical direction
Retroreflective
Type
Vacuumresistant
Fiber
head
4,000
157.480
3,000
118.110
L
5.5mm
0.217in
4,000
157.480
600
23.622
HYPR
500
19.685
400
15.748
STD
300
11.811
200
7.874
Reflector
H-SP
ℓ
L
100
3.937
0
20
0.787
Fiber
head
10
0
10
0.394
0.394
Left
Center
Right
Operating point ℓ (mm in)
FRA014
20
0.787
STD
300
11.811
200
7.874
Reflector
H-SP
ℓ
L
100
3.937
0
20
0.787
Fiber
head
10
0
10
0.394
0.394
Down
Center
Up
Operating point ℓ (mm in)
20
0.787
FTA204
Retroreflective type
Horizontal direction
Vertical direction
1,200
47.244
1,200
47.244
HYPR
500
19.685
400
15.748
FR-KZ50E
HYPR
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
0
10
0.394
STD
Reflector
RF-003
ℓ
H-SP
L
Fiber
head
5
0
5
0.197
0.197
Left
Center
Right
Operating point ℓ (mm in)
10
0.394
Setting distance L (mm in)
Convergent
Reflective
Type
1,000
39.370
Horizontal direction
Setting distance L (mm in)
Wide
Beam
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
Fiber
ℓ head
H-SP
FT-Z30HW FTA200
Sleeve
Narrow
Beam
L
Fiber
head
2,000
78.740
Setting distance L (mm in)
400
15.748
Square Head
Type
Small
Spot
ℓ
1,000
39.370
Threaded
Type
Flat
Type
Fiber
head
H-SP
Vertical direction
HYPR
3,000
118.110
STD
Setting distance L (mm in)
2,000
78.740
HYPR
3,000
118.110
STD
0
Super
Quality
Setting distance L (mm in)
3,000
118.110
Fibers
Cylindrical
Type
HYPR
Setting distance L (mm in)
Earlier models
comparison
table
4,000
157.480
Setting distance L (mm in)
How to read
Model No
Horizontal direction
4,000
157.480
Setting distance L (mm in)
Choose
by shape/
application
Setting distance L (mm in)
Model
Thru-beam type
Vertical direction
Setting distance L (mm in)
Horizontal direction
4,000
157.480
FT-Z30H
Thru-beam type
Setting distance L (mm in)
FT-Z30EW
Fiber
Selection
Guide
Setting distance L (mm in)
Tough
Fiber
HYPR
1,000
39.370
800
31.496
600
23.622
STD
400
15.748
H-SP
Reflector
RF-003
ℓ
3mm
0.118in
L
200
7.874
0
10
0.394
Fiber
head
5
0
5
0.197
0.197
Down
Center
Up
Operating point ℓ (mm in)
10
0.394
85
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Tough
Fiber
Retroreflective type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
FR-KZ50H
Retroreflective type
Vertical direction
Fiber
Selection
Guide
1,200
47.244
1,200
47.244
Model
HYPR
1,000
39.370
800
31.496
600
23.622
STD
400
15.748
H-SP
Reflector
RF-003
ℓ
L
200
7.874
Fiber
head
0
20
0.787
10
0
10
0.394
0.394
Left
Center
Right
Operating point ℓ (mm in)
Setting distance L (mm in)
Setting distance L (mm in)
Horizontal direction
Choose
by shape/
application
800
31.496
How to read
Model No.
600
23.622
STD
400
15.748
H-SP
20
0.787
Earlier models
comparison
table
Reflector
RF-003
ℓ
L
200
7.874
0
20
0.787
HYPR
1,000
39.370
Fiber
head
10
0
10
0.394
0.394
Down
Center
Up
Operating point ℓ (mm in)
Fibers
20
0.787
Super
Quality
FR-Z50HW
Retroreflective type
2,000
78.740
1,500
59.055
STD
1,000
39.370
H-SP
Reflective tape
RF-13
ℓ
500
19.685
L
Fiber
head
1,500
59.055
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
STD
1,000
39.370
Reflective tape
RF-13
ℓ
H-SP
500
19.685
0
150
5.906
HYPR
0
150
5.906
150
5.906
L
Fiber
head
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
Setting distance L (mm in)
HYPR
Setting distance L (mm in)
Setting distance L (mm in)
2,000
78.740
With reflector RF-230 (optional)
Horizontal direction
Vertical direction
4,000
157.480
4,000
157.480
HYPR
3,000
118.110
STD
2,000
78.740
H-SP
HYPR
3,000
118.110
STD
2,000
78.740
H-SP
Reflector
RF-230
ℓ
1,000
39.370
L
Fiber
head
Setting distance L (mm in)
FRA013
With Reflective tape RF-13 (attached)
FRA013
Horizontal direction
Vertical direction
Cylindrical
Type
Flat
Type
Small
Spot
Narrow
Beam
Reflector
RF-230
ℓ
Wide
Beam
L
Fiber
head
0
400 300 200 100 0 100 200 300 400
15.748 11.811 7.874 3.937
3.937 7.874 11.811 15.748
Down
Center
Up
Operating point ℓ (mm in)
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No.
FRA010
Reflective type
FD-30
Vertical direction
800
31.496
HYPR
600
23.622
STD
400
15.748
0
150
5.906
L
Fiber
head
H-SP
Left
HYPR
0
150
5.906
150
5.906
STD
White
non-glossy paper
ℓ
L
Fiber
head
H-SP
Up
Down
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
FDA262
Vertical direction
400
15.748
400
15.748
Setting distance L (mm in)
Setting distance L (mm in)
Horizontal direction
FDA262
100
3.937
0
60
2.362
200
7.874
100
3.937
0
150
5.906
150
5.906
HYPR
STD
H-SP
White
non-glossy paper
ℓ
L
Fiber
head
Left
Right
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
60
2.362
0
60
2.362
H-SP
Left
Right
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
FD-32G
150
5.906
Reflective type
FDA256
STD
H-SP
L
Fiber
head
Up
Down
40
20
0
20
40
1.575 0.787
0.787 1.575
Down
Center
Up
Operating point ℓ (mm in)
60
2.362
STD
H-SP
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
HYPR
500
19.685
400
15.748
STD
300
11.811
200
7.874
100
3.937
0
150
5.906
Semi-custom
fibers
White
non-glossy paper
ℓ
L
Fiber
head
H-SP
Up
Down
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
FDA256
150
5.906
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
FX-500
series
White
non-glossy paper
ℓ
FX-100
series
L
Fiber
head
200
7.874
0
200
7.874
Retroreflective
Type
Amplifiers
400
15.748
White
non-glossy paper
ℓ
Convergent
Reflective
Type
HYPR
600
23.622
200
7.874
100
3.937
White
non-glossy paper
ℓ
L
Fiber
head
800
31.496
300
11.811
200
7.874
STD
300
11.811
Reflective type
300
11.811
600
23.622
HYPR
400
15.748
FD-31W
HYPR
Vertical direction
500
19.685
400
15.748
Right
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
600
23.622
600
23.622
200
7.874
FRA011
Horizontal direction
Setting distance L (mm in)
200
7.874
White
non-glossy paper
ℓ
Setting distance L (mm in)
Setting distance L (mm in)
800
31.496
Setting distance L (mm in)
Horizontal direction
FD-31
FRA011
Reflective type
Setting distance L (mm in)
FRA010
Square Head
Type
Sleeve
1,000
39.370
0
400 300 200 100 0 100 200 300 400
15.748 11.811 7.874 3.937
3.937 7.874 11.811 15.748
Left
Center
Right
Operating point ℓ (mm in)
150
5.906
Threaded
Type
Left
Right
100
0
100
3.937
3.937
Left
Center
Right
Operating point ℓ (mm in)
FDA233
200
7.874
INDEX
86
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No.
600
23.622
Heatresistant
Semi-custom
fibers
H-SP
Left
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
400
15.748
100
3.937
White non-glossy paper
ℓ
L
Fiber
head
H-SP
Left
Reflective
Type
Up
Down
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
Setting distance L (mm in)
600
23.622
STD
H-SP
White
non-glossy paper
ℓ
L
Fiber
head
200
7.874
0
200
7.874
L
Fiber
head
H-SP
Up
Down
20
0
20
0.787
0.787
Down
Center
Up
Operating point ℓ (mm in)
Left
Right
100
0
100
3.937
3.937
Left
Center
Right
Operating point ℓ (mm in)
200
7.874
STD
H-SP
White
non-glossy paper
ℓ
L
Fiber
head
200
7.874
100
3.937
300
11.811
200
7.874
White
non-glossy paper
ℓ
L
Fiber
head
H-SP
100
3.937
Left
Right
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
Left
Right
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
100
3.937
White
non-glossy paper
ℓ
400
15.748
L
Fiber
head
H-SP
Left
Right
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
STD
White
non-glossy paper
ℓ
L
Fiber
head
H-SP
400
15.748
H-SP
100
3.937
50
0
50
1.969
1.969
Down
Center
Up
Operating point ℓ (mm in)
HYPR
600
23.622
STD
400
15.748
200
7.874
Left
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
FDA260
White
non-glossy paper
ℓ
L
Fiber
head
H-SP
Up
Down
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
150
5.906
Right
400
15.748
HYPR
1,500
59.055
STD
1,000
39.370
500
19.685
White
non-glossy paper
ℓ
L
Fiber
head
H-SP
Up
Down
0
0.000
400
15.748
200
0
200
7.874
0.000
7.874
Down
Center
Up
Operating point ℓ (mm in)
Setting distance L (mm in)
Setting distance L (mm in)
FDA203
FDA235
100
3.937
800
31.496
2,000
78.740
HYPR
1,500
59.055
0
200
7.874
Reflective type
FDA218
Vertical direction
FDA218
Horizontal direction
500
19.685
Up
Down
STD
300
11.811
0
150
5.906
150
5.906
FD-60
1,000
39.370
400
15.748
1,000
39.370
STD
200
7.874
L
Fiber
head
Reflective type
FDA223
Vertical direction
800
31.496
600
23.622
White non-glossy paper
ℓ
HYPR
500
19.685
0
100
3.937
100
3.937
HYPR
2,000
78.740
600
23.622
0
STD
0
150
5.906
HYPR
400
15.748
400
15.748
FD-41W
40
1.575
Reflective type
FDA224
800
31.496
600
23.622
500
19.685
1,000
39.370
White non-glossy paper
ℓ
FD-42GW
Vertical direction
FDA223
Horizontal direction
STD
40
1.575
40
1.575
HYPR
400
15.748
100
3.937
Reflective type
HYPR
0
100
3.937
150
5.906
300
11.811
200
7.874
150
5.906
Horizontal direction
FDA261
600
HYPR
0
Reflective type
FDA224
800
31.496
Others
Right
20
0
20
0.787
0.787
Left
Center
Right
Operating point ℓ (mm in)
FD-42G
Retroreflective
Type
INDEX
H-SP
400
15.748
STD
200
7.874
40
1.575
Thru-beam
Type
FX-100
series
L
Fiber
head
Vertical direction
HYPR
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
FD-41S
Reflective type
FDA258
300
11.811
Fiber
Dimensions
FX-500
series
100
3.937
0
150
5.906
150
5.906
Horizontal direction
0
Amplifiers
Right
White
non-glossy paper
ℓ
200
7.874
FD-41SW FDA258
Setting distance L (mm in)
Fiber
Options
L
Fiber
head
Up
Down
23.622
STD
300
11.811
White
non-glossy paper
ℓ
L
Fiber
head
H-SP
150
5.906
HYPR
400
15.748
STD
200
7.874
White
non-glossy paper
ℓ
0
150
5.906
500
19.685
200
7.874
0
150
5.906
Right
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
600
23.622
HYPR
300
11.811
100
3.937
Left
Reflective type
FDA261
Vertical direction
400
15.748
Chemical / Oilresistant
Liquid Leak /
Liquid Detection
200
7.874
500
19.685
Retroreflective
Type
Vacuumresistant
100
0
100
3.937
3.937
Left
Center
Right
Operating point ℓ (mm in)
H-SP
0
150
5.906
STD
400
15.748
Setting distance L (mm in)
Convergent
Reflective
Type
Right
Fiber
head
600
23.622
Setting distance L (mm in)
Wide
Beam
Left
L
200
7.874
HYPR
Setting distance L (mm in)
Narrow
Beam
L
Fiber
head
ℓ
Setting distance L (mm in)
Small
Spot
H-SP
200
7.874
White
non-glossy paper
STD
400
15.748
White
non-glossy paper
ℓ
FDA234
Horizontal direction
Setting distance L (mm in)
Flat
Type
STD
400
15.748
FD-41
Sleeve
800
31.496
HYPR
Setting distance L (mm in)
Threaded
Type
Cylindrical
Type
Vertical direction
600
23.622
600
23.622
0
200
7.874
Super
Quality
Square Head
Type
HYPR
Setting distance L (mm in)
Fibers
800
31.496
Setting distance L (mm in)
Earlier models
comparison
table
Setting distance L (mm in)
How to read
Model No
Reflective type
Horizontal direction
800
31.496
Model
Choose
by shape/
application
FD-40
Reflective type
Setting distance L (mm in)
FD-32GX
Fiber
Selection
Guide
Setting distance L (mm in)
Tough
Fiber
FDA260
400
15.748
87
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Tough
Fiber
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No.
Vertical direction
1,500
59.055
1,500
59.055
White
non-glossy
paper
ℓ
STD
500
19.685
L
Fiber
head
H-SP
Left
0
Right
400
200
0
200
400
15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
1,000
39.370
White
non-glossy
paper
STD
ℓ
500
19.685
L
Fiber
head
H-SP
0
600
23.622
600
23.622
1,200
47.244
HYPR
Up
Down
400
200
0
200
400
15.748 7.874
7.874 15.748
Down
Center
Up
Operating point ℓ (mm in)
FD-61S
1,500
59.055
HYPR
1,000
39.370
STD White
non-glossy paper
ℓ
500
19.685
L
Fiber
head
H-SP
Left
0
400
15.748
Setting distance L (mm in)
Setting distance L (mm in)
FDA259
Vertical direction
1,500
59.055
Right
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
STD
500
19.685
L
Fiber
head
H-SP
Up
Down
0
400
15.748
400
15.748
400
15.748
200
0
200
7.874
7.874
Down
Center
Up
Operating point ℓ (mm in)
FD-62
H-SP
600
23.622
Left
Fibers
Right
400
200
0
200
400
15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
600
23.622
Super
Quality
FD-61W
Reflective type
FDA200
Horizontal direction
Vertical direction
1,000
39.370
HYPR
800
31.496
STD
600
23.622
White
non-glossy paper
ℓ
400
15.748
200
7.874
0
150
5.906
400
15.748
L
Fiber
head
H-SP
Left
Right
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
FD-64X
Flat
Type
600
23.622
STD
400
15.748
0
150
5.906
150
5.906
Small
Spot
White
non-glossy paper
ℓ
Narrow
Beam
L
Fiber
head
H-SP
Up
Down
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
150
5.906
Vertical direction
FDA216
Horizontal direction
2,000
78.740
2,000
78.740
800
31.496
800
31.496
600
23.622
Left
Right
400
200
0
200
400
15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
600
23.622
250
9.843
STD
150
5.906
White
non-glossy paper
200mm
7.874in
ℓ
H-SP
50
1.969
L
Fiber
head
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
FDA225
200
7.874
0
600
23.622
300
11.811
60
2.362
150
5.906
100
3.937
H-SP
50
1.969
0
60
2.362
White
non-glossy
paper
200mm
7.874in
ℓ
L
Fiber
head
40
20
0
20
40
1.575 0.787
0.787 1.575
Down
Center
Up
Operating point ℓ (mm in)
FDA225
60
2.362
L
Fiber
head
Left
L
Fiber
head
H-SP
Up
Down
200
100
0
100
200
7.874 3.937
3.937 7.874
Down
Center
Up
Operating point ℓ (mm in)
300
11.811
Reflective type
FDA248
Vertical direction
Horizontal direction
800
31.496
HYPR
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
HYPR
600
23.622
600
23.622
400
15.748
0
300
11.811
300
11.811
Retroreflective
Type
ℓ
0
300
11.811
FD-AL11 FDA248
200
7.874
200
7.874
White
non-glossy
paper
STD
400
15.748
Right
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
800
31.496
200
7.874
White
non-glossy paper
ℓ
H-SP
STD
Setting distance L (mm in)
Setting distance L (mm in)
400
200
0
200
400
15.748 7.874
7.874 15.748
Down
Center
Up
Operating point ℓ (mm in)
250
9.843
200
7.874
0
60
2.362
Up
Down
Reflective type
FDA220
Vertical direction
FDA220
Horizontal direction
100
3.937
H-SP
0
600
23.622
FD-A16
L
Fiber
head
STD
400
15.748
Setting distance L (mm in)
H-SP
500
19.685
White
non-glossy paper
ℓ
HYPR
600
23.622
STD
ℓ
H-SP
400
15.748
White
non-glossy
paper
L
Fiber
head
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
FDA252
Setting distance L (mm in)
0
L
Fiber
head
STD
1,000
39.370
HYPR
600
23.622
Setting distance L (mm in)
500
19.685
White
non-glossy paper
ℓ
1,500
59.055
Setting distance L (mm in)
STD
1,000
39.370
Setting distance L (mm in)
1,500
59.055
HYPR
Wide
Beam
Convergent
Reflective
Type
Chemical / Oilresistant
FDA222
Horizontal direction
HYPR
Square Head
Type
Sleeve
HYPR
800
31.496
200
7.874
Threaded
Type
Cylindrical
Type
Reflective type
FDA216
Vertical direction
Setting distance L (mm in)
Reflective type
FDA222
L
Fiber
head
200
7.874
0
Earlier models
comparison
table
ℓ
1,000
39.370
White
non-glossy
paper
ℓ
How to read
Model No.
White
non-glossy
paper
STD
600
23.622
HYPR
1,000
39.370
Choose
by shape/
application
800
31.496
600
23.622
Reflective type
FDA259
Horizontal direction
Model
HYPR
1,000
39.370
Setting distance L (mm in)
1,000
39.370
Reflective type
Fiber
Selection
Guide
Setting distance L (mm in)
HYPR
Setting distance L (mm in)
Setting distance L (mm in)
Horizontal direction
600
23.622
FD-61G
Reflective type
Setting distance L (mm in)
FD-61
300
11.811
STD
Amplifiers
White
non-glossy
paper
FX-500
series
ℓ
200 H-SP
7.874
0
300
11.811
3.6mm
0.142in L
Fiber
head
200
100
0
100
200
7.874 3.937
3.937 7.874
Down
Center
Up
Operating point ℓ (mm in)
FDA252
FX-100
series
300
11.811
INDEX
88
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Tough
Fiber
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No.
FD-E13
10
0.394
Left
0
15
0.591
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Small
Spot
Narrow
Beam
Wide
Beam
Setting distance L (mm in)
Sleeve
Flat
Type
L
Fiber
head
Convergent
Reflective
Type
150
5.906
STD
100
3.937
H-SP
ℓ
50
1.969
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
80
3.150
Setting distance L (mm in)
Horizontal direction
ℓ
L
STD
20
0.787
H-SP
Fiber
Dimensions
STD
H-SP
2
0
2
0.079
0.079
Left
Center
Right
Operating point ℓ (mm in)
20
10
0
10
20
0.787 0.394
0.394 0.787
Left
Center
Right
Operating point ℓ (mm in)
80
3.150
Setting distance L (mm in)
Others
HYPR
40
1.575
STD
0
4
0.157
Transparent glass
Emitter
L
H-SP
2
0
2
0.079
0.079
Down
Center
Up
Operating point ℓ (mm in)
4.5mm
0.177in
40
1.575
100mm, (t=0.7mm)
3.937in, (t=0.028in)
ℓ
L
STD
20
0.787
H-SP
0
4
0.157
ℓ
4
0.157
Vertical direction
HYPR
10
0.394
H-SP
ℓ
50
1.969
L
Fiber
head
20
0
20
0.787
0.787
Left
Center
Right
Operating point ℓ (mm in)
60
2.362
40
1.575
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
FD-H13-FM2
Reflective type
FDA243
60
2.362
FDA246
ℓ
1,000
39.370
L
Fiber
head
HYPR
500
19.685
STD
H-SP
0
400
15.748
30
1.181
Reflective type
30
1.181
40
1.575
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
FD-H20-21
Transparent glass
100mm,(t=0.7mm)
3.937in,(t=0.028in)
60
2.362
20
0.787
4
0.157
Horizontal direction
40
1.575
ℓ
White
non-glossy
paper
200mm
7.874in
L
Fiber
head
FD-H25-L43
Reflective
Type
White
non-glossy
paper
200mm
7.874in
STD
100
3.937
400
15.748
FD-H20-M1
Reflective type
Reflective type
Vertical direction
4mm
0.157in
40
1.575
150
5.906
0
0
15
0.591
HYPR
White non-glossy paper
20
0.787
30
1.181
White
non-glossy
paper
200mm
7.874in
ℓ
L
Fiber
head
HYPR
60
2.362
40
1.575
H-SP
50
1.969
Reflective type
HYPR
4
0.157
INDEX
10
5
0
5
10
0.394 0.197
0.197 0.394
Down
Center
Up
Operating point ℓ (mm in)
80
3.150
0
60
2.362
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
60
2.362
0
FX-100
series
White
non-glossy
paper
200mm
7.874in
L
Fiber
head
Liquid Leak /
Liquid Detection
FX-500
series
Up
Down
100
3.937
Vacuumresistant
Amplifiers
0
15
0.591
15
0.591
HYPR
FD-H18-L31
Retroreflective
Type
L
Fiber
head
200
7.874
60
2.362
Thru-beam
Type
H-SP
10
0.394
Right
10
5
0
5
10
0.394 0.197
0.197 0.394
Left
Center
Right
Operating point ℓ (mm in)
Heatresistant
Semi-custom
fibers
20
0.787
STD
100
3.937
Reflective type
FD-EG31 FDA242
Chemical / Oilresistant
Fiber
Options
STD
30
1.181
150
5.906
White
non-glossy
paper
200mm
7.874in
ℓ
Reflective type
FD-EG30S FDA242
0
Retroreflective
Type
40
1.575
Setting distance L (mm in)
H-SP
50
1.969
HYPR
30
1.181
20
0.787
STD
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
Emitter
ℓ
L
H-SP
10
0.394
0
2
0
2
0.079
0.079
Left
Center
Right
Operating point ℓ (mm in)
4
0.157
4
0.157
2
0
2
0.079
0.079
Down
Center
Up
Operating point ℓ (mm in)
4
0.157
White non-glossy paper
ℓ
L
Fiber
head
HYPR
1,000
39.370
500
19.685
STD
H-SP
0
200
7.874
100
0
100
3.937
3.937
Left
Center
Right
Operating point ℓ (mm in)
200
7.874
Setting distance L (mm in)
20
0.787
Reflective type
200
7.874
HYPR
Setting distance L (mm in)
STD
30
1.181
Setting distance L (mm in)
Fibers
White
non-glossy
paper
200mm
7.874in
ℓ
Setting distance L (mm in)
Earlier models
comparison
table
40
1.575
Setting distance L (mm in)
How to read
Model No
200
7.874
HYPR
Setting distance L (mm in)
50
1.969
60
2.362
HYPR
Setting distance L (mm in)
Choose
by shape/
application
Setting distance L (mm in)
Model
FD-EG30
Reflective type
Vertical direction
Horizontal direction
60
2.362
FD-E23
Reflective type
Setting distance L (mm in)
Fiber
Selection
Guide
HYPR
1,000
39.370
STD
500
19.685
White
non-glossy paper
H-SP
0
200
7.874
ℓ
L
Fiber
head
100
0
100
3.937
3.937
Left
Center
Right
Operating point ℓ (mm in)
200
7.874
89
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No.
Tough
Fiber
(Models with same sensing characteristics are grouped together.)
Vertical direction
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
4.5mm
0.177in
ℓ
L
STD
H-SP
Emitter ℓ
STD
H-SP
20
0.787
2
0
2
0.079
0.079
Left
Center
Right
Operating point ℓ (mm in)
4
0.157
4
0.157
1
0
1
0.039
0.039
Left
Center
Right
Operating point ℓ (mm in)
H-SP
2
0.079
2
0.079
1
0
1
0.039
0.039
Down
Center
Up
Operating point ℓ (mm in)
Transparent
glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
2
0.079
L
6
0.236
HYPR
STD
2
0.079
FD-H35-M2
FD-H35-M2S6
4
0.157
2
0.079
Vertical direction
L
H-SP
0
0.5
0
0.5
0.020
0.020
Left
Center
Right
Operating point ℓ (mm in)
FDA251
1
0.039
10
0.394
5
0.197
0
1
0.039
STD
H-SP
0.5
0
0.5
0.020
0.020
Down
Center
Up
Operating point ℓ (mm in)
FDA251
1
0.039
200
7.874
200
7.874
Small
Spot
Fiber head
Narrow
Beam
STD
Wide
Beam
Convergent
Reflective
Type
H-SP
100
0
100
3.937
3.937
Left
Center
Right
Operating point ℓ (mm in)
HYPR
H-SP
L
15
0.591
2
0
2
0.079
0.079
Left
Center
Right
Operating point ℓ (mm in)
4
0.157
HYPR
STD
10
0.394
200
7.874
H-SP
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Transparent glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
2mm
L
0.079in
Fiber
Options
5
0.197
4
0.157
Semi-custom
fibers
2
0
2
0.079
0.079
Down
Center
Up
Operating point ℓ (mm in)
50
1.969
HYPR
40
1.575
STD
30
1.181
20
0.787
H-SP
10
0.394
0
15
0.591
White
non-glossy paper
200mm
7.874in
ℓ
L
Fiber
head
10
5
0
5
10
0.394 0.197
0.197 0.394
Left
Center
Right
Operating point ℓ (mm in)
FDA226
4
0.157
15
0.591
Fiber
Dimensions
Thru-beam
Type
FDA231
Reflective type
FD-L20H FDA231
Horizontal direction
Transparent glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
1.5mm
L
0.059in
HYPR
Flat
Type
L
0
4
0.157
Setting distance L (mm in)
STD
15
0.591
Setting distance L (mm in)
Transparent glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
HYPR
Sleeve
Vertical direction
Transparent glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
5
0.197
3
0.118
Cylindrical
Type
HYPR
400
15.748
0
2
1
0
1
2
0.079 0.039
0.039 0.079
Down
Center
Up
Operating point ℓ (mm in)
Square Head
Type
Reflective
type
ℓ
400
15.748
Super
Quality
Threaded
Type
Reflective type
STD
10
0.394
2
0.079
White non-glossy paper
600
23.622
0
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
15
0.591
FDA232
Reflective type
FDA232
Horizontal direction
STD
H-SP
Horizontal direction
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
ℓ
2mm
L
0.079in
H-SP
3
0.118
3
0.118
500
19.685
1
0
1
0.039
0.039
Down
Center
Up
Operating point ℓ (mm in)
FD-L11
0
2
1
0
1
2
0.079 0.039
0.039 0.079
Left
Center
Right
Operating point ℓ (mm in)
HYPR
Earlier models
comparison
table
Fibers
2
0.079
800
31.496
Fiber head
How to read
Model No.
L
H-SP
0
2
0.079
White non-glossy paper
ℓ
L
1,000
39.370
0
400
15.748
Setting distance L (mm in)
STD
Setting distance L (mm in)
Setting distance L (mm in)
HYPR
FD-L12W
Setting distance L (mm in)
L
Reflective type
4
0.157
1
0.039
1
0
1
0.039
0.039
Left
Center
Right
Operating point ℓ (mm in)
ℓ
Choose
by shape/
application
STD
20
0.787
FD-H35-20S Reflective type
0
H-SP
5
0.197
ℓ
STD
8
0.315
10
0.394
2
0.079
4
0.157
10
0.394
Vertical direction
15
0.591
H-SP
Emitter
HYPR
40
1.575
Setting distance L (mm in)
H-SP
Emitter
8
0.315
3
0.118
L
Setting distance L (mm in)
L
HYPR
Horizontal direction
0
ℓ
STD
20
0.787
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
FD-L10
6
0.236
40
1.575
Setting distance L (mm in)
ℓ
20
0.787
Setting distance L (mm in)
Setting distance L (mm in)
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
0
2
0.079
HYPR
Model
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
60
2.362
Vertical direction
STD
10
0.394
60
2.362
Reflective type
Horizontal direction
HYPR
80
3.150
Transparent glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
0
2
0
2
0.079
0.079
Down
Center
Up
Operating point ℓ (mm in)
FD-H30-L32V-S
20
0.787
L
80
3.150
0
0
4
0.157
40
1.575
Fiber
Selection
Guide
Vertical direction
Setting distance L (mm in)
40
1.575
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
HYPR
Setting distance L (mm in)
Setting distance L (mm in)
HYPR
Reflective type
Horizontal direction
Setting distance L (mm in)
Horizontal direction
20
0.787
FD-H30-L32
Reflective type
Setting distance L (mm in)
FD-H25-L45
Retroreflective
Type
Vertical direction
Reflective
Type
50
1.969
Others
HYPR
40
1.575
STD
Amplifiers
30
1.181
White non-glossy paper
200mm
7.874in
ℓ
20
0.787
H-SP
10
0.394
0
15
0.591
L
Fiber
head
10
5
0
5
10
0.394 0.197
0.197 0.394
Down
Center
Up
Operating point ℓ (mm in)
FDA226
15
0.591
FX-500
series
FX-100
series
INDEX
90
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Tough
Fiber
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No.
20
0.787
Threaded
Type
Square Head
Type
L
2
0
2
0.079
0.079
Left
Center
Right
Operating point ℓ (mm in)
Transparent
glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
2.5mm
L
0.098in
04
0.157
4
0.157
2
0
2
0.079
0.079
Down
Center
Up
Operating point ℓ (mm in)
Setting distance L (mm in)
Setting distance L (mm in)
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
ℓ
H-SP
H-SP
6
0.236
Transparent
glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
20
0.787
10
0.394
L
4
2
0
2
4
0.157 0.079
0.079 0.157
Left
Center
Right
Operating point ℓ (mm in)
H-SP
30
1.181
Transparent glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
2.5mm
L
0.098in
20
0.787
10
0.394
0
6
0.236
6
0.236
FDA202
Horizontal direction
Setting distance L (mm in)
120
4.724
HYPR
100
3.937
80
3.150
STD
60
2.362
Transparent glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
R edge(R0.35 R0.014)
ℓ
L
40
1.575
20
0.787
0
10
0.394
5
0
5
0.197
0.197
Left
Center
Right
Operating point ℓ (mm in)
FDA230
10
0.394
120
4.724
80
3.150
STD
60
2.362
Transparent
glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
R edge
(R0.35
R0.014)
ℓ
0
10
0.394
5
0
5
0.197
0.197
Down
Center
Up
Operating point ℓ (mm in)
FDA230
L
10
0.394
06
0.236
HYPR
STD
H-SP
Transparent
glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
2.5mm
L
0.098in
4
2
0
2
4
0.157 0.079
0.079 0.157
Down
Center
Up
Operating point ℓ (mm in)
H-SP
20
0.787
10
0.394
4
2
0
2
4
0.157 0.079
0.079 0.157
Left
Center
Right
Operating point ℓ (mm in)
40
1.575
HYPR
STD
30
1.181
H-SP
Transparent
glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
3mm
L
0.118in
20
0.787
10
0.394
0
6
0.236
6
0.236
4
2
0
2
4
0.157 0.079
0.079 0.157
Down
Center
Up
Operating point ℓ (mm in)
Vertical direction
1,200
47.244
HYPR
1,000
39.370
800
31.496
STD
400
15.748
200
7.874
0
300
11.811
6
0.236
FDA229
Reflective type
FD-R60
600
23.622
6
0.236
Vertical direction
L
1,200
47.244
40
1.575
20
0.787
30
1.181
6
0.236
HYPR
100
3.937
STD
2
0.079
Reflective type
FDA205
FDA229
Horizontal direction
Vertical direction
35
1.378
30
1.181
25
0.984
20
0.787
15
0.591
10
0.394
5
0.197
6
0.236
Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in)
ℓ
HYPR
0
6
0.236
FDA202
Reflective type
FD-L32H
Others
4
2
0
2
4
0.157 0.079
0.079 0.157
Down
Center
Up
Operating point ℓ (mm in)
Setting distance L (mm in)
6
0.236
STD
Setting distance L (mm in)
H-SP
40
1.575
Setting distance L (mm in)
Setting distance L (mm in)
30
1.181
STD
HYPR
L
1
0
1
0.039
0.039
Down
Center
Up
Operating point ℓ (mm in)
FD-L31A
40
1.575
40
1.575
3mm
0.118in
Vertical direction
4
2
0
2
4
0.157 0.079
0.079 0.157
Left
Center
Right
Operating point ℓ (mm in)
50
1.969
HYPR
5
0.197
Transparent
glass
200mm
7.874in
(t=2.0mm)
(t=0.079in)
ℓ
Reflective type
FDA228
L
0
4
0.157
Reflective type
FDA201
STD
Vertical direction
Retroreflective
Type
INDEX
H-SP
STD
H-SP
10
0.394
2
0.079
4
0.157
Transparent
glass
100mm
3.937in
(t=0.7mm)
(t=0.028in)
ℓ
HYPR
50
1.969
Thru-beam
Type
FX-100
series
STD
HYPR
FDA205
Horizontal direction
Fiber
Dimensions
FX-500
series
HYPR
STD
15
0.591
FDA228
FDA201
Horizontal direction
0
Amplifiers
FD-L23
Reflective type
FDA227
FD-L30A
Liquid Leak /
Liquid Detection
2
0
2
0.079
0.079
Left
Center
Right
Operating point ℓ (mm in)
35
1.378
30
1.181
25
0.984
20
0.787
15
0.591
10
0.394
5
0.197
04
0.157
Vacuumresistant
4
0.157
3
0.118
Horizontal direction
Heatresistant
Reflective
Type
2
1
0
1
2
0.079 0.039
0.039 0.079
Down
Center
Up
Operating point ℓ (mm in)
HYPR
0
0
35
1.378
30
1.181
25
0.984
20
0.787
15
0.591
10
0.394
5
0.197
Chemical / Oilresistant
Semi-custom
fibers
3
0.118
5
0.197
Vertical direction
Retroreflective
Type
Fiber
Options
Fiber
head
0
6
0.236
L
H-SP
10
0.394
35
1.378
30
1.181
25
0.984
20
0.787
15
0.591
10
0.394
5
0.197
Setting distance L (mm in)
Wide
Beam
3mm
0.118in
Transparent
glass
200mm
7.874in
(t=2.0mm)
(t=0.079in)
ℓ
L
FDA227
Horizontal direction
Sleeve
Convergent
Reflective
Type
5
0.197
FD-L22A
Cylindrical
Type
Narrow
Beam
4
2
0
2
4
0.157 0.079
0.079 0.157
Left
Center
Right
Operating point ℓ (mm in)
H-SP
10
0.394
STD
15
0.591
20
0.787
Setting distance L (mm in)
6
0.236
STD
15
0.591
Transparent glass
200mm, (t=2.0mm)
7.874in, (t=0.079in)
ℓ
HYPR
Setting distance L (mm in)
0
Super
Quality
Small
Spot
Emitter
H-SP
5
0.197
Fibers
Flat
Type
L
HYPR
Setting distance L (mm in)
10
0.394
STD
Setting distance L (mm in)
Earlier models
comparison
table
15
0.591
Transparent glass
200mm, (t=2.0mm)
7.874in, (t=0.079in)
ℓ
HYPR
Vertical direction
Setting distance L (mm in)
Horizontal direction
20
0.787
Setting distance L (mm in)
Vertical direction
20
0.787
Setting distance L (mm in)
How to read
Model No
Reflective type
Horizontal direction
Model
Choose
by shape/
application
FD-L21W
Reflective type
Setting distance L (mm in)
FD-L21
Fiber
Selection
Guide
White
non-glossy
paper
ℓ
L
Fiber
head
H-SP
Left
Right
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
FDA240
300
11.811
HYPR
1,000
39.370
800
31.496
STD
600
23.622
400
15.748
200
7.874
0
300
11.811
White
non-glossy
paper
ℓ
L
Fiber
head
H-SP
Up
Down
200
100
0
100
200
7.874 3.937
3.937 7.874
Down
Center
Up
Operating point ℓ (mm in)
FDA240
300
11.811
91
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Tough
Fiber
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No.
Vertical direction
H-SP
Left
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
STD
L
Fiber
head
H-SP
0
150
5.906
Left
Right
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
FD-S32
Setting distance L (mm in)
HYPR
White
non-glossy paper
ℓ
500
19.685
L
Fiber head
H-SP
Left
Right
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
FD-S33GW
400
15.748
FDA221
Setting distance L (mm in)
L
STD
400
15.748
Left
Right
H-SP
200
7.874
100
3.937
150
5.906
FDA236
100
3.937
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
1,000
39.370
non-glossy paper
ℓ
500
19.685
L
Fiber head
H-SP
Up
Down
200
0
200
7.874
7.874
Down
Center
Up
Operating point ℓ (mm in)
STD
400
15.748
150
5.906
400
15.748
Fiber head
Left
STD
200
7.874
White
non-glossy paper
ℓ
L
Fiber head
H-SP
Left
50
1.969
Right
25
0
25
0.984
0.984
Left
Center
Right
Operating point ℓ (mm in)
FDA221
50
1.969
White non-glossy paper
ℓ
200
7.874
100
3.937
L
Fiber
head
H-SP
Up
Down
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
150
5.906
STD
400
15.748
White
non-glossy paper
ℓ
L
0
150
5.906
150
5.906
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
600
23.622
200
7.874
Narrow
Beam
HYPR
800
31.496
Fiber head
H-SP
Semi-custom
fibers
Up
Down
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
FDA219
150
5.906
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
HYPR
400
15.748
Amplifiers
STD White
FX-500
series
non-glossy paper
ℓ
200
7.874
L
Fiber head
H-SP
FX-100
series
Up
Down
0
50
1.969
STD
Others
600
23.622
400
15.748
Cylindrical
Type
Sleeve
300
11.811
FDA219
Vertical direction
HYPR
Square Head
Type
Small
Spot
Reflective type
FDA221
Super
Quality
400
15.748
Right
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
FD-S60Y
600
23.622
White
non-glossy paper
ℓ
Fibers
Threaded
Type
HYPR
1,000
39.370
H-SP
0
60
2.362
Reflective type
FDA257
Vertical direction
L
200
7.874
40
20
0
20
40
1.575 0.787
0.787 1.575
Down
Center
Up
Operating point ℓ (mm in)
Flat
Type
150
5.906
HYPR
600
23.622
Up
Down
0
150
5.906
800
31.496
Earlier models
comparison
table
500
19.685
Right
Horizontal direction
0
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
H-SP
FD-S32W FDA257
STD White
White non-glossy paper
ℓ
Fiber head
L
Fiber
head
Left
1,000
39.370
0
400
15.748
White
non-glossy
paper
ℓ
How to read
Model No.
L
Fiber
head
50
1.969
600
23.622
200
7.874
Horizontal direction
600
23.622
0
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
H-SP
White
non-glossy
paper
200mm
7.874in
Reflective type
FDA245
Vertical direction
STD
0
150
5.906
ℓ
60
2.362
FDA245
400
15.748
100
3.937
STD
100
3.937
60
2.362
HYPR
300
11.811
Choose
by shape/
application
0
500
19.685
HYPR
Reflective type
HYPR
Up
Down
Vertical direction
STD
800
31.496
L
1,500
59.055
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
Model
HYPR
150
5.906
Right
Horizontal direction
Fiber
head
150
5.906
Fiber head
FD-S31
White
non-glossy
paper
ℓ
H-SP
White
non-glossy
paper
200mm
7.874in
L
Left
60
2.362
Reflective type
FDA263
1,000
39.370
H-SP
600
23.622
STD
ℓ
50
1.969
150
5.906
600
23.622
200
7.874
STD
100
3.937
0
HYPR
400
15.748
150
5.906
0
150
5.906
Horizontal direction
0
400
15.748
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
FDA263
1,500
59.055
Up
Down
Setting distance L (mm in)
White
non-glossy
paper
ℓ
Setting distance L (mm in)
Setting distance L (mm in)
600
23.622
200
7.874
L
Fiber
head
H-SP
800
31.496
HYPR
400
15.748
White
non-glossy paper
ℓ
Reflective type
FDA216
Vertical direction
FDA216
Horizontal direction
800
31.496
200
7.874
0
150
5.906
150
5.906
FD-S30
STD
400
15.748
Setting distance L (mm in)
0
150
5.906
Right
600
23.622
Setting distance L (mm in)
L
Fiber
head
800
31.496
200
7.874
HYPR
Setting distance L (mm in)
White
non-glossy paper
ℓ
400
15.748
Setting distance L (mm in)
STD
600
23.622
Setting distance L (mm in)
Setting distance L (mm in)
800
31.496
200
7.874
HYPR
Fiber
Selection
Guide
Vertical direction
Setting distance L (mm in)
1,000
39.370
HYPR
Setting distance L (mm in)
1,000
39.370
Reflective type
Horizontal direction
Setting distance L (mm in)
Horizontal direction
200
7.874
FD-S21
Reflective type
Setting distance L (mm in)
FD-R61Y
25
0
25
0.984
0.984
Down
Center
Up
Operating point ℓ (mm in)
FDA221
50
1.969
INDEX
92
SENSING CHARACTERISTICS (TYPICAL)
New product
introduction
Tough
Fiber
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No.
STD
100
3.937
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
250
9.843
200
7.874
STD
150
5.906
100
3.937
50
1.969
Thru-beam
Type
White
non-glossy
paper
ℓ
3.5mm L
0.138in
Fiber
head
H-SP
20
10
0
10
20
0.787 0.394
0.394 0.787
Left
Center
Right
Operating point ℓ (mm in)
Setting distance L (mm in)
HYPR
200
7.874
50
1.969
0
30
1.181
STD
White
non-glossy paper
30
1.181
1.2mm
0.047in
H-SP
Fiber
head
H-SP
100
3.937
200
7.874
H-SP
0
80 60 40 20
0
20 40 60 80
3.150 2.362 1.575 0.787
0.787 1.575 2.362 3.150
Left
Center
Right
Operating point ℓ (mm in)
FDA347
HYPR
STD
200
7.874
H-SP
White
non-glossy
paper
ℓ
1.2mm L
0.047in
Fiber head
0
80 60 40 20
0
20 40 60 80
3.150 2.362 1.575 0.787
0.787 1.575 2.362 3.150
Down
Center
Up
Operating point ℓ (mm in)
FDA347
L
Fiber
head
STD
200
7.874
H-SP
100
3.937
40
20
0
20
40
1.575 0.787
0.787 1.575
Down
Center
Up
Operating point ℓ (mm in)
800
31.496
400
15.748
STD
200
7.874
H-SP
White
non-glossy
paper
ℓ
L
Fiber
head
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
HYPR
2,500
98.425
600
23.622
400
15.748
STD
200
7.874
H-SP
1,000
39.370
60
2.362
4mm
0.158in L
Fiber
head
0
150
5.906
150
5.906
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
150
5.906
FDA250
Reflective type
White non-glossy paper
ℓ
L
Fiber
head
STD
H-SP
500
19.685
0
ℓ
White
non-glossy
paper
Vertical direction
2,000
78.740
1,500
59.055
60
2.362
HYPR
FD-Z50HWFDA250
Reflective type
FDA346
400
15.748
300
11.811
Vertical direction
HYPR
3,000
118.110
STD
3.5mm
0.138in
FDA249
Reflective type
600
23.622
150
5.906
30
1.181
20
0.787
White non-glossy paper
ℓ
HYPR
60
2.362
FDA249
Horizontal direction
Horizontal direction
HYPR
400
15.748
60
2.362
0
600
23.622
10
0
10
0.394
0.394
Down
Center
Up
Operating point ℓ (mm in)
0
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
800
31.496
400
15.748
Setting distance L (mm in)
STD
200
7.874
Vertical direction
Fiber head
Fiber head
20
0.787
White non-glossy paper
ℓ
L
800
31.496
600
23.622
H-SP
20
0.787
Vertical direction
Fiber
head
FDA436
Horizontal direction
White non-glossy paper
ℓ
4.0mm L
0.158in
40
1.575
0
20
0.787
White
non-glossy
paper
200mm
7.874in
ℓ
L
STD
FD-Z40HBW
Setting distance L (mm in)
Setting distance L (mm in)
Others
L
20
10
0
10
20
0.787 0.394
0.394 0.787
Down
Center
Up
Operating point ℓ (mm in)
FD-Z40W
Reflective
Type
ℓ
60
2.362
FDA238
Reflective type
HYPR
800
31.496
250
9.843
100
3.937
10
0
10
0.394
0.394
Left
Center
Right
Operating point ℓ (mm in)
300
11.811
60
2.362
HYPR
150
5.906
L
Fiber
head
0
100
3.937
FDA239
Reflective type
300
11.811
20
0.787
HYPR
80
3.150
FD-Z20HBW
FDA238
Fiber head
50
0
50
1.969
1.969
Down
Center
Up
Operating point ℓ (mm in)
Vertical direction
30
1.181
Retroreflective
Type
White
non-glossy
paper
ℓ
L
300
11.811
0
Fiber
Dimensions
INDEX
STD
100
3.937
100
3.937
White non-glossy paper
200mm
7.874in
ℓ
H-SP
400
15.748
H-SP
0
40
1.575
STD
Horizontal direction
300
11.811
100
3.937
60
2.362
20
0.787
HYPR
200
7.874
80
3.150
Setting distance L (mm in)
Fiber head
100
3.937
Setting distance L (mm in)
White
L non-glossy paper
Horizontal direction
Setting distance L (mm in)
Liquid Leak /
Liquid Detection
FX-100
series
400
15.748
Vertical direction
HYPR
0
80 60 40 20
0
20 40 60 80
3.150 2.362 1.575 0.787
0.787 1.575 2.362 3.150
Down
Center
Up
Operating point ℓ (mm in)
FD-Z20W FDA239
Vacuumresistant
FX-500
series
Fiber head
Vertical direction
H-SP
100
3.937
White
non-glossy paper
200mm
7.874in
ℓ
L
Reflective type
FDA237
HYPR
200
7.874
0
Heatresistant
ℓ
300
11.811
Chemical / Oilresistant
Amplifiers
H-SP
50
1.969
Setting distance L (mm in)
Setting distance L (mm in)
400
15.748
Retroreflective
Type
Semi-custom
fibers
100
3.937
0
FDA237
Horizontal direction
Sleeve
Fiber
Options
STD
FD-V50
Cylindrical
Type
Wide
Beam
150
5.906
80 60 40 20
0
20 40 60 80
3.150 2.362 1.575 0.787
0.787 1.575 2.362 3.150
Left
Center
Right
Operating point ℓ (mm in)
Square Head
Type
Convergent
Reflective
Type
L
Fiber
head
200
7.874
0
Threaded
Type
Narrow
Beam
ℓ
50
1.969
Super
Quality
Small
Spot
H-SP
White
non-glossy
paper
200mm
7.874in
HYPR
Setting distance L (mm in)
100
3.937
Fibers
Flat
Type
STD
100
3.937
Setting distance L (mm in)
150
5.906
Setting distance L (mm in)
Earlier models
comparison
table
HYPR
Reflective type
Horizontal direction
Setting distance L (mm in)
200
7.874
250
9.843
Setting distance L (mm in)
Choose
by shape/
application
Setting distance L (mm in)
Model
How to read
Model No
Vertical direction
Horizontal direction
250
9.843
FD-V30W
Reflective type
Setting distance L (mm in)
FD-V30
Fiber
Selection
Guide
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
FDA241
60
2.362
3,000
118.110 HYPR
2,500
98.425
ℓ
White non-glossy
L paper
Fiber head
2,000
78.740
1,500
59.055
1,000
39.370
STD
H-SP
500
19.685
0
60
2.362
40
20
0
20
40
1.575 0.787
0.787 1.575
Down
Center
Up
Operating point ℓ (mm in)
FDA241
60
2.362
93
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Wiring
• Make sure that the power supply is OFF while adding or
removing the amplifiers.
• Note that if a voltage exceeding the reted range is
applied, or if an AC power supply is directly connected,
the product may get burnt or damaged.
• Note that short-circuit of the load or wrong wiring may
burn or damage the product.
• Do not run the wires together with high-voltage lines or
power lines, or put them in the same raceway.
This can cause malfunction due to induction.
• Verify that the supply voltage variation is within the rating.
• If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
• In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this
product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
• Make sure to use the quick-connection cable (optional)
for the connection of the controller.
Extension up to total 100 m 328.084 ft is possible with
0.3 mm2 or more, cable.
However, in order to reduce noise, make the wiring as
short as possible.
• Make sure that stress by forcible bending or pulling is not
applied to the sensor cable joint and fiber cable.
Refer to the “PRO mode operation manual” on our website for details.
Others
• Our products have been developed / produced for
industrial use only.
• The specification may not be satisfied in a strong
magnetic field.
• The ultra long distance (U-LG, HYPR) mode is more
likely to be affected by extraneous noise since the
sensitivity of that is higher than the other modes. Make
sure to check the environment before use.
• Do not use during the initial transient time (H-SP, FAST,
STD: 0.5 sec., LONG, U-LG, HYPR: 1 sec.) after the
power supply is switched ON.
• These sensors are only for indoor use.
• Avoid dust, dirt, and steam.
• Make sure that the product does not come in contact with
oil, grease, organic solvents such as thinner, etc., strong
acid or alkaline.
• This product cannot be used in an environment
containing inflammable or explosive gases.
• Never disassemble or modify this product.
• This product adopts EEPROM. Settings cannot be done
a million times or more because of the EEPROM's
lifetime.
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
94
New product
introduction
Tough
Fiber
PRECAUTIONS FOR PROPER USE
Abstract from “PRO MODE OPERATION MANUAL”
Part description
Symbol explanation
SET
SET key (Confirm)
: Press the SET key.
UP (+) key (Select)
Fiber
Selection
Guide
Model
Choose
by shape/
application
Response time
SET setting (Note 1)
250μs or less +, -
SET
2ms or less +, -
4ms or less
+, -
+, +, 25μs or less
Response time
Fibers
“
”, “
“
”
“
”, “
”, “
”
OFF-delay
timer
+, -
ON-delay
timer
+, -
Flat
Type
+, -
Sensing output 2 +, -
External input
+, -
“ms”
Approx. 0.5ms, Approx. 1 to 9,999ms
Approx. 0.5 sec., Approx. 1 to 32 sec.
Input / output setting SET
SET Copy setting
YES
SET
Large +, -
Copy action
setting
Convergent
Reflective
Type
Automatic
SET
Display
adjustment
Copy lock setting
Displayed in
percentage
SET
+, -
Incident light
intensity (Note 3)
Response time
“
”, “
“
”
“
”, “
”, “
”
Max. 4,000
+, -
Vacuumresistant
Liquid Leak /
Liquid Detection
Max. 9,999
Copy lock OFF
+, -
Copy lock ON
SET
Communication
mode
+, -
Communication
emission halt
Only displayed in FX-502□ or FX-505□-C2
SET SET
External input
setting (Note 6)
Correcting
SET
Only one unit SET
Timer range
setting
Semi-custom
fibers
+, Copy lock
1/10ms
+, -
Teaching lock
SET setting
SET
All SET
+, -
Retroreflective
Type
Setting items in
digital display setting SET
+, -
+, -
Data bank
save
Data bank
load
+, -
Emission OFF +, -
Teaching
+, -
Lock ON
Limit +
+, -
Reflective
Type
Incident light
intensity
+, -
+, -
Displayed in
percentage +, -
Peak /
bottom value
SET
Turning OFF +, -
SET
Eco OFF +, -
Turning ON
+, ECO setting
Limit -
+, -
+, -
Data bank
save
Data bank
load
+, -
Notes: 6) The signal input time from outside is as follows.
Eco ON +, -
Full
+, +, -
+, Time period hold
setting (Note 5)
Display adjustment
+, -
+, Setting of digital
display turning
Others
SET
Hold OFF +, -
Hold ON
Notes: 5) In order to clear the value, set the time period holding
function to OFF once. Turning the power OFF can also
clear the value.
INDEX
Logic setting
+, -
Thru-beam
Type
FX-100
series
Lock OFF +, -
+, -
Display adjustment
+, sec. +, -
Limit -
+, -
” when the
Notes: 4) In case the response time setting is set to “
hysteresis setting is “
” , the emitting power becomes
low sensibility (“
”) whichever selecting “
”, “
” or
“
”.
ms +, -
Limit +
+, -
SET High emission power +, - Middle emission power +, - Low emission power
SET
Teaching
+, -
+, +, -
Emission OFF +, -
+, -
Automatic
Automatic
In case saturation
correction is NG,
it is not displayed.
+, -
SET
+, -
Max. 8,000
”
Saturation correction SET
Fiber
Options
Display
adjustment OFF
Incident light intensity
+, -
Emission power
setting (Note 4)
Display copy +, -
+, Communication
protocol setting
Notes: 3) Incident light intensity setting depends on the response times.
Chemical / Oilresistant
FX-500
series
+, -
Small
+, -
Retroreflective
Type
Heatresistant
good
Automatic
+, -
2 turns
+, -
Approx. 0.05ms, Approx. 0.1 to 999.9ms
+, Shift amount
setting
Blinks
3 times
Only displayed in FX-502□
+, -
Wide
Beam
good
+, -
Blink
Back up OFF
SET
Blinks
3 times
+, -
“sec.”
Standard +, -
SET
Back up ON
Timer period
“1/10ms”
+, -
YES
1 ch +, -
+, -
+, -
Timer range
Narrow
Beam
+, -
ON / OFF-delay
ON-delay /
One-shot
timer
One-shot timer
timer
(Except sensing output 2)
(Except sensing output 2)
Notes: 2) When using time, be sure to set the time range.
Since the setting time depends on timer range as table
below, set the setting time after selecting the timer
range.
Sleeve
Hysteresis
setting
Back up setting
+, +, -
Small
Spot
+, -
Max. 9,999
good
+, -
Blink
Changeable 1 to
Automatic
8ch in + or -
Max. 4,000
+, -
Square Head
Type
Changeable 1 to
Automatic
8ch in + or -
Data bank saving
setting
SET
Max. 8,000
YES
1 ch +, -
SET
+, -
24ms or less
Incident light intensity
”
No timer +, -
SET
Threaded
Type
Cylindrical
Type
Data bank
SET loading setting
Notes: 1) Display of incident light intensity depends on the response time.
+, -
Timer setting
+,
+, -
60μs or less
Super
Quality
Automatic
: Automatically move to next
MODE indicator: PRO (Yellow)
PRO mode
Earlier models
comparison
table
Amplifiers
: Press the UP (+) key or
DOWN (-) key.
MODE key
(Select, cancel)
How to read
Model No
Fiber
Dimensions
+, -
DOWN (-) key (Select)
Input time
2 point teaching
Limit teaching
Display adjust
Full auto teaching
Emission OFF, Logic setting
Copy lock
Data bank loading
Data bank saving
20 to under 500ms
600ms or more (sampling during input)
2ms or more (conducted during inputting)
Input pulse of the specified channel number
(1 pulse: 16 to 300ms).
However, the pulse cycle is under 500ms.
(
95
PRECAUTIONS FOR PROPER USE
New product
introduction
Tough
Fiber
Abstract from “PRO MODE OPERATION MANUAL”
ion
y.
key or
Fiber
Selection
Guide
ve to next
Model
+, good
SET Code setting
Choose
by shape/
application
+, -
Blinks
3 times
SET
SET
Logic operation
setting
SET
Between
adjacent amplifier
SET
Invalid +, -
and
Earlier models
comparison
table
+, +, Display
adjustment setting SET
good
Target setting
(Note 7)
Confirm +, -
OFF +, -
Blinks
3 times
xor
Between external
input
SET
Display
0 SET adjustment setting
Target setting SET
Confirm
Confirm
Confirm
Response time
”, “
“
+, +, -
Reset setting
y
ment OFF
”,“
“
”
“
”, “
”
Setting of threshold
Setting of threshold
value tracking
SET tracking cycle
SET
Blink
Emission power
setting
+, -
Sensing output
setting
SET
Hysteresis
setting
or
1 sec.
OFF +, -
Default
Storage cycle
setting
OFF +, -
ON
OFF +, -
1 time
+, Limit teaching
+, -
Auto teaching
Different frequency setting SET Emission frequency 1 +, - Emission frequency 2
+, -
Teaching
Emission frequency 3
+, Limit +
+, -
(Note 8) SET
Window
comparator mode
Rising differential
Trailing differential
Normal mode +, - (Except sensing output 2) +, - mode (Note 9)
+, - mode (Note 9)
Limit -
+, -
+, -
Forced OFF
output mode
+, -
+, +, Forced ON
output mode
bank
Hysteresis
mode
In case FX-502□ or FX-505□-C2, by
pressing down MODE key long time,
sensing output 1 or 2 can be changed
to another.
ic setting
+, -
+, -
(The following diagram shows in selecting the window comparator mode.)
Limit +
Shift amount setting
SET (Displayed in percentage) SET
+, +, -
Limit -
+, -
SET
SET
+, -
+, -
Shift amount setting (Note 11)
bank
Notes: 8) : Set the sensing output setting after input / output setting for FX-502□.
9) In case using in differential mode, set threshold value 20 or more when the hys” and set threshold value 80 or more when the hysteresis
teresis setting is “
setting is “
” or “
”.
10) After external input, the time given until an answer back output is as follows. However, in case
timer of the sensing output 2 is valid, the output time is different from the following table.
ng)
number
ms.
Input time
After 20ms from the input end, the answer back
output is read out when result of the teaching is “
”.
After 20ms from the input end, the answer back
Display adjust
output is read out.
After 520ms from rising of last input pulse, the anData bank loading
swer back output (pulse) of the number of channel in
Data bank saving
the data bank is read out.
11) Incident light intensity depends on the response time as table below.
2 point teaching
Limit teaching
Full auto teaching
Response time
“
”, “
“
”
“
”, “
”, “
Shift direction
Sensing output ON
Light-ON
-
Sensing output ON
Dark-ON
+
Sensing output OFF
Light-ON
+
Sensing output OFF
Dark-OFF
-
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
Incident light intensity
”
Max. 4,000
Max. 8,000
”
Sensing output status
Sensing output
operation
Convergent
Reflective
Type
Self-diagnosis
output mode
(Except sensing output 1)
Answer back output
mode (Note 10)
(Except sensing output 1)
+, -
Narrow
Beam
+, Only displayed in
FX-502□ or FX-505□-C2
Only displayed in
FX-505□-C2
Teaching
+, -
”, conduct the limit teaching for the
Notes: 12) In case setting to “
changed incident light intensity.
Shift direction of the threshold differs depending on the combination of the sensing output status and the sensing output
operation.
+, -
Flat
Type
Wide
Beam
SET
Algorithm setting
(Note 12)
SET
+, -
Sleeve
Small
Spot
+, +, -
+, -
+, Interference
prevention setting SET
Cylindrical
Type
+, -
+, -
Blinks 3 times
+, Response time
setting
+, -
Square Head
Type
+, xor
+, -
From -1,999 to 9,999
Automatic
SET
CUSTOM setting SET
and
From -1,999 to 4,000
From -1,999 to 8,000
SET
Threaded
Type
+, -
Target setting
”
Invalid +, +, -
Notes 7) Target setting of display adjust setting depends on the response time as table below.
good
or
xor
Between sensing output 1
and sensing output 2
SET
-
Fibers
Super
Quality
+, +, -
+, -
SET
SET
SET
and
Invalid +, +, -
+, -
Incident light
intensity
or
Only displayed in FX-502□ or FX-505□-C2
+, -
+, -
+, +, -
+, -
How to read
Model No.
Max. 9,999
INDEX
96
New product
introduction
Tough
Fiber
FX-501(P) FX-502(P)
Output selection indicator
(Yellow) (Note 1)
Fiber
Selection
Guide
Model
Choose
by shape/
application
Fibers
Super
Quality
Cylindrical
Type
8.2
0.323
Beamemitting
part
27.8 1.094
22.7 0.894
32
1.260 28 20.8
1.102
0.819
7 0.276
Beamreceiving
part
Output selection indicator
(Yellow)
MODE key
Setting switch
Communication window
10
0.394
FX-505-C2 FX-505P-C2
8.2
0.323
Amplifier
62.5 2.461
2 0.079
9.95
0.392
MODE key
Output 1 operation indicator
(Orange)
Output 2 operation indicator
(Orange) (Note 1)
24 0.945
36.5 1.437
3
75 2.953
0.118
Suitable for 35 mm 1.378 in width DIN rail
Output 2 operation indicator
(Orange)
Digital display (Green / Red)
10
Beam- 0.394
emitting
part
Setting switch
27.8 1.094
22.7 0.894
7
0.276
1.1 0.043
7 0.276
10.5
0.413
5.7 0.224
Threaded
Type
Square Head
Type
Amplifier
9.95
62.5 2.461
0.392
2 0.079
Digital display (Green / Red)
Output 1 operation indicator
(Orange) (Note 2)
How to read
Model No
Earlier models
comparison
table
Refer to p.48 ~ for details of fiber dimensions.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
Communication window
ø4 ø0.157
cable 2 m 6.562 ft
32 28
1.260 1.102 20.8
7 0.276
0.819
Beamreceiving
part
10.5
0.413 9.2
0.362
5.7 0.224
24 0.945
3
0.118
3.95
0.156
(Note 3)
36.5 1.437
3.95
0.156
2.8 0.110
75 2.953
Suitable for 35 mm 1.378 in width DIN rail
Notes: 1) FX-502(P) only
2) FX-501(P): Operation indicator
3) FX-501(P): 3-pin, FX-502(P): 4-pin
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
CN-73-C□ CN-74-C□
• Length L
Length L
CN-73/74-C1
1,000 39.370
CN-73/74-C2
2,000 78.740
CN-73/74-C5
5,000 196.850
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
(Note 1)
2.65
0.104
14
(0.551
)
2.9
(0.114
)
2.54
0.100
Notes: 1) CN-74-C□ only
2) CN-73-C□: 3-core
7
0.276
10
0.394
13.6
0.535
3
0.118
21.6 0.850
16 0.630
5.2
0.205
Reflective
Type
0.4
0.016 ø1.8
ø0.071
7.5
0.295 4.2 0.165
35
1.378
2
0.079
2
0.079
2-ø3.2 ø0.126 holes
Material: C
old rolled carbon steel (SPCC)
(Uni-chrome plated)
FX-500
series
FX-100
series
INDEX
1,000 39.370
CN-71/72-C2
2,000 78.740
CN-71/72-C5
5,000 196.850
14
(0.551
)
2.54
0.100
3
0.118
2.9
(0.114
)
2.54
0.100
0.2
0.008
7
0.276
10
0.394
13.6
0.535
MS-DIN-E
3
0.118
5
0.197
15
0.591
60
2.362
3
0.118
5.6 M3 square nut
0.220
24.7
0.972
1.6
0.063
( )
7.2
0.283
End plate (Optional)
M3 (length 18 mm 0.709 in) pan head screws
3
0.118
10
0.394
6
0.236
12 10.5
(0.472
) 0.413
2.65
0.104
7.2
0.283
50
1.969
ø3.3 ø0.130 cable
2.75
0.108
3.2
0.126
t1
t 0.039
27
1.063
(Note 2)
Notes: 1) CN-72-C□ only
2) CN-71-C□: 1-core
5.2
0.205
Others
Amplifiers
CN-71/72-C1
10
0.394
3.2
0.126
L
Length L
( )
Amplifier mounting bracket (Optional)
Fiber
Dimensions
Retroreflective
Type
Sub cable (Optional)
Model No.
(Note 1)
0.2
0.008
8.5
0.335
Thru-beam
Type
10
0.394
6
0.236
12 10.5
(0.472
) 0.413
MS-DIN-2
Semi-custom
fibers
(Note 2)
50
1.969
ø3.3 ø0.130 cable
2.54
0.100
Chemical / Oilresistant
CN-71-C□ CN-72-C□
• Length L
L
Model No.
Retroreflective
Type
Heatresistant
Main cable (Optional)
32
1.260
Material: Polycarbonate
4
0.157
Suitable for 35 mm 1.378 in width DIN rail
97
98
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Digital Fiber Sensor
FX-100 SERIES
Taking fiber sensors to the next level
Model
Choose
by shape/
application
How to read
Model No
Conforming to
EMC Directive
Listing
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
* The FX-100 series has been changed to Panasonic brand from production in and after July 2011.
* Cover opened state is shown.
Small
Spot
PNP output
type available
Timer
Automatic
sensitivity setting
Test input
Interference Light intensity
monitor
prevention
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Good dual digital display
The threshold value and incident light intensity can
be both confirmed at the same time, bringing good
operability when making changes of each setting.
Threshold value
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Commercially-available connectors reduce lead time and spare part numbers
Compatible with commercially-available connectors, so that
processing costs and lead time required for processing after
purchase can be greatly reduced. The connection parts same as
the DP-100 series digital pressure sensors and the PM-64 series
micro photoelectric sensors can be commonly used.
Reflective
Type
Conventional (cable type)
FX-500
series
FX-100
series
INDEX
Conventional lead time
● Harness processing by outside order is needed after sensor preparation.
Customer
Purchase and preqaration of sensor
Harness processing by outside order
Sensor installation
Sensor preparation
Harness
processor
From now on (built-in connector type)
Others
Amplifiers
Commercially-available
connector
Commercially-available crimping connectors are used, so that
the processing costs for connection cables can be greatly
reduced.
Thru-beam
Type
Retroreflective
Type
Incident light intensity
Sensor installation
Harness processing
Lead time from now on
● Harness processing can be done by outside order at the
same time of sensor preparation. No need junction connector.
Customer
Sensor preparation
Sensor installation
Purchase and preqaration of sensor
Harness processing by outside order
Sensor installation
Harness
processor
Using cables with connectors
Harness processing
Lead time further reduced
● Harness processing by outside order is not needed.
Lead time and spare part numbers can be reduced.
Purchase and preqaration of
sensors and cable with connectors
Sensor installation
Customer
Reduced
Sensor preparation
Sensor installation
Reduced
Reduced
lead time
99
Saving-space with a width of 9 mm 0.354 in
Improved stability over long terms
Very slim body at only 9 mm 0.354 in. This is much
thinner than existing fiber sensors. This makes a very
large difference when using many units, even if the
difference of one unit is small.
Utilizes “Four-chemical emitting element” for light
emission. The light emission is guaranteed to be stable
over long periods of time.
[Stable sensing comparison]
Light-emitting
amount
9 mm
0.354 in
FX-100
Three-chemical
emitting element
Incident light intensity
Threshold value
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No.
Long-term
stability
Earlier models
comparison
table
Time
Simple operation due to clear configuration system
Fibers
Continued to use the configuration system of digital pressure sensor DP-100 series, which has received high
popularity since its release. We have separated the settings into three levels: RUN mode, SET mode, and PRO
mode, making operation simpler and easier.
Functions used during normal operation
RUN mode
• Changing threshold values • Key lock
• Quick settings • Code settings
Functions used when initializing
the sensor and carrying out maintenance
Simple setting
SET mode
• Teaching • L-ON / D-ON setting
• Timer setting • Emission amount
• Emission frequency setting
Equipped with a full complement
of digital fiber sensor functions
PRO mode
• Shift setting
• Reset
• ECO
• Threshold value margin
• Threshold value follow-up cycle
Special and detailed setting
• External input
• GETA
• Inverting display
• Copy
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Quick code input function
Simply imputing the default setting “code (number)”
will enable sensor settings. Even if the settings are
accidentally changed, imputing the code will restore the
default settings.
Confirmation can be carried out smoothly via telephone
by simply quoting numbers. This can be of great
assistance when dealing with foreign country customers.
New product
introduction
RUN mode
Fiber
Options
Quick setting: Press
and
simultaneously for 2 sec.
Code setting: Press
and
simultaneously for 4 sec.
Semi-custom
fibers
Fiber
Dimensions
Quick setting numbers (abstract)
No
Output
operation
Timer
Emission amount
setting
Thru-beam
Type
Retroreflective
Type
Dark-ON
None
OFF
Dark-ON
None
ON
Reflective
Type
Dark-ON
OFF-delay 10 ms
OFF
Others
Dark-ON
OFF-delay 10 ms
ON
Light-ON
ON-delay 40 ms
ON
Light-ON
ON-delay 40 ms
OFF
Amplifiers
Light-ON
ON-delay 10 ms
ON
FX-500
series
Light-ON
ON-delay 10 ms
OFF
FX-100
series
Refer to “Quick setting function” and “Code setting function”
in “PRECAUTIONS FOR PROPER USE” for details.
INDEX
100
100
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Teaching with ON / OFF keys
SET mode
Simply press the ON key when an object is present, and
OFF when it is not, and teaching is completed. There is
no need to consider difference between Light-ON and
Dark-ON.
Thru-beam type / Retroreflective type
Choose
by shape/
application
Resolves variation in incident light intensity display
PRO mode
GETA function
Even when performing the same sensing operation,
there may be variances in the digital values of the fiber
amp. There is no problem with the sensor itself, but the
operator may find it troubling.
Given value can be corrected with the GETA function, so
the apparent variation can be eliminated and the creation
of operation manuals can proceed smoothly.
How to read
Model No
Earlier models
comparison
table
Variations in the amount of light received
Object present ON
Object absent OFF
Fibers
Super
Quality
Reflective type
Unify at 500 using
the GETA function
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Object present ON
Object absent OFF
Small
Spot
Narrow
Beam
Example of current incident light intensity display of ‘
’
adjusted to ‘
Chemical / Oilresistant
Heatresistant
Vacuumresistant
4,000
[digits]
500
current value
0
500
Not
displayed
Liquid Leak /
Liquid Detection
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
PRO mode
This function performs automatic setting to threshold
value by checking the incident light intensity at desired
intervals in order to follow the changes in the light
amount resulting from changes in the environment over
long periods (such as dust). Contributes to reduction in
maintenance hours.
* Effective when the output
operation is set to Dark-ON,
and when using thru-beam type
or retroreflective type fibers.
Current value
Incident light
intensity when an
object is absent.
A
4000
Actual digit difference: C
Upper display limit
Light emitting
amount decreased
B
Time
SET mode
Emission amount can be reduced in order to achieve
stable detection when the receiving light level is
saturated, such as detection at close range and
detection of transparent or minute objects. Previously,
the emission amount level was only one, but from
production in December 2007, four level setting (three
level + auto setting) has become available. This function
brings easier settings than before.
【Light receiving level saturated】
Threshold value
0
Emission amount setting
function
Incident light
intensity
Semi-custom
fibers
Threshold value follow-up cycle
setting function
Incident light intensity
Fiber
Options
Because the original
value is 500, sensor
displays 500 for the
lower limit value
and 4,000 for the
upper limit value.
1,000
Saturated digit
difference: D
【Stable sensing】
Incident light
intensity
Retroreflective
Type
Teaching even without an object
— Limit teaching function
Threshold value can be set by performing teaching only
when an object is absent (when the incident light amount
is stable). This is useful when there are other objects in
the background also when defecting a minute objects.
Teaching can also be carried out using external input.
4,000
[digits]
Incident light intensity
Wide
Beam
Convergent
Reflective
Type
’ is
,
A
,
B
Actual digit difference: C
101
101
Emission frequency setting mode SET mode
Mutual interference is prevented for max. 3 units for
standard type FX-101□ and max. 4 units in case of long
sensing range type FX-102□.
During setting of interference prevention, emitter and
output indicator both flash, so it is convenient to confirm
which fiber is in the setting process at a glance. Emitter
flashes even when an amplifier is not installed close
together.
* When the emission frequency is changed, a response time is also
changed.
Setting copy function to reduce man-hours
PRO mode
and human error
By connecting a fiber sensor to the master fiber sensor,
the master sensor settings can be copied along with
data communications. When the same settings are
input to several units, trouble from setting errors can be
prevented, also changes to the work order will be small
when equipment design is changed.
Color of lead wire of attached connector cable
(Black) Output
+
–
(White) External input
External input setting mode
PRO mode
External input can be selected from emission halt, limit
teaching / full-auto teaching / 2-level teaching, ECO
or emission amount test. Threshold value set at each
teaching is also memorized.
* 2-level teaching, emission amount test and threshold value storing
setting are available in amplifiers manufactured after December 2007.
Color of lead wire of attached connector cable
(Brown) +V
(White) External input
Super
Quality
(Black) Output
(White) External input
Threaded
Type
(Blue) 0 V
Square Head
Type
These settings can be copied
Threshold value, output operation, timer operation, timer
emission amount, shift, external input, threshold valuestoring, ECO inverting digital display, and threshold value
margin
PLC etc.
(Blue) 0 V
External input lines are
equipped as standard
Without mounting bracket
Sleeve
Flat
Type
Small
Spot
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Digital display inversion setting PRO mode
Vacuumresistant
The viewing orientation of the digital display can be
inverted in accordance with the setting direction of the
amplifier.
Previous products
(without inversion function)
Cylindrical
Type
Narrow
Beam
Selectable either mounting on DIN rail or direct mounting
with through hole.
Direct mounting brings stability even on a movable parts or
installation of a single unit.
(Black) Output
How to read
Model No.
Fibers
(Brown) +V
The emitter and output indicator flash
at the same frequency.
Model
12 to 24 V DC
±10 %
(Blue) 0 V
Slave side
Fiber
Selection
Guide
Earlier models
comparison
table
(Brown) +V
Copy
Tough
Fiber
Choose
by shape/
application
Master side
New product
introduction
Liquid Leak /
Liquid Detection
FX-100 SERIES
ø3.2 mm 0.126 in mounting holes
Fiber
Options
Can be mounted with M3 screws.
Turn OFF
Available from standard type or long
sensing range type
Turn ON
Alert function
PRO mode
When the amount light received approaches the
threshold value, the display can be made to blink in order
to alert the operator.
Incident light intensity
The amount of light received ranges from about 900 to 1,100
when the digital indicator flashes.
Range of the digital indicator flashing
(margin: small)
1,100 approx.
900 approx.
The digital indicator flashes.
Semi-custom
fibers
Threshold value
of 1,000
Standard type and long sensing range type are available
which has various response time and sensing range.
The model best meet application needs can be selected.
Model No.
Type
Sensing range
(FT-B8)
Response time
FX-101
Standard type
400 mm 15.748 in
Max. 250 μs
FX-102
Long sensing range type 1,150 mm 45.276 in
Max. 2.5 ms
Power consumption saving with
ECO mode
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
ECO
When there is no key operations in approximately 20
seconds, digital display turns off and power consumption
can be reduced to 600mW or less (720mW in normal
mode).
FX-500
series
FX-100
series
INDEX
102
102
New product
introduction
Tough
Fiber
ORDER GUIDE
Amplifiers
Type
Appearance
Fiber
Selection
Guide
M8 plug-in
connector
type
Earlier models
comparison
table
Cable set
(Note 1)
How to read
Model No
Standard type
Choose
by shape/
application
M8 plug-in
connector
type
Model
Fibers
Super
Quality
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
M8 plug-in
connector
type
M8 plug-in
connector
type
Cylindrical
Type
Cable set
(Note 1)
Square Head
Type
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
NPN open-collector
transistor
FX-101-Z (Note 3)
NPN open-collector
transistor
FX-101P (Note 2)
PNP open-collector
transistor
FX-101P-Z (Note 3)
PNP open-collector
transistor
FX-101-CC2
NPN open-collector
transistor
FX-101P-CC2
PNP open-collector
collector transistor
FX-102 (Note 2)
NPN open-collector
transistor
FX-102-Z (Note 3)
NPN open-collector
transistor
FX-102P (Note 2)
PNP open-collector
transistor
FX-102P-Z (Note 3)
PNP open-collector
transistor
FX-102-CC2
NPN open-collector
transistor
FX-102P-CC2
PNP open-collector
transistor
Accessory
• CN-14A-C2
Connector attached
cable 2 m 6.562 ft
* Only include cable set type
• FC-FX-1 (Protection cover)
* It have been attached from the
production at July, 2011.
Notes: 1) The connector attached cable 2 m CN-14A-C2 is supplied with the amplifier.
2) M
ake sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg. Co., Ltd.
(contact: SPHD-001T-P0.5, housing: PAP-04V-S)
3) Make sure to use the optional M8 connector attached cable CN-24A-C□.
OPTIONS
Designation
Model No.
Description
1 m 3.281 ft
CN-14A-C2 (Note)
2 m 6.562 ft
CN-14A-C3
3 m 9.843 ft
CN-14A-C5
5 m 16.404 ft
CN-14A-R-C1
1 m 3.281 ft
CN-14A-R-C2
2 m 6.562 ft
CN-14A-R-C3
3 m 9.843 ft
CN-14A-R-C5
5 m 16.404 ft
M8 connector
attached cable
CN-24A-C2
2 m 6.562 ft
CN-24A-C5
5 m 16.404 ft
Connector
CN-14A
Set of 10 housings and 40 contacts
Connector
attached cable
Connector
attached cable
(Flexible type)
Amplifier
MS-DIN-4
mounting bracket
End plates
MS-DIN-E
Two pcs. per set
M8 connector attached cable
• CN-24A-C□
31.4
1.236
CN-14A-C1
Fiber
Options
Semi-custom
fibers
Output
FX-101 (Note 2)
Red LED
Long sensing range type
Threaded
Type
Emitting
element
Model No.
0.2 mm2 4-core cabtyre cable with connector
on one end
Cable outer diameter: ø3.7 mm ø0.146 in
ø9
ø0.354
ø4
ø0.157
M8 connector
attached cable
CN-24A-C□
Fixing ring
For M8 plug-in connector type
The connector on one end
Cable outer diameter: ø4 mm ø0.157 in
Amplifier mounting
bracket
• MS-DIN-4
Mounting bracket for amplifier
When it moves depending on the way it is installed on a DIN rail,
these end plates ensure that all amplifiers are mounted together
in a secure and fully connected manner.
Others
Note: The connector attached cable CN-14A-C2 is supplied with the cable set type FX-10□-CC2.
Amplifiers
Recommended connector
Connector
attached cable
• CN-14A(-R)-C□
FX-500
series
FX-100
series
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Connector
• CN-14A
Contact
Recommended crimping tool
INDEX
Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Housing
103
103
SPECIFICATIONS
Model No.
Type
Item
New product
introduction
Standard type
Long sensing range type
Cable set
Cable set
NPN output
FX-101(-Z) (Note 5)
FX-101-CC2
FX-102(-Z) (Note 5)
FX-102-CC2
PNP output
FX-101P(-Z) (Note 5)
FX-101P-CC2
FX-102P(-Z) (Note 5)
FX-102P-CC2
Supply voltage
Power consumption
Output
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 100 mA
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less (at 100 mA sink current)
• Residual voltage: 1.5 V or less (at 100 mA source current)
Output operation
Response time
Environmental resistance
Ambient temperature
3-level + Auto setting (from production in December 2007)
Incorporated
Emission frequency selection method (Note 2)
(Functions at emission frequency 1, 2, 3 or 4)
–10 to +55 °C +14 to +131 °F (If 4 to 7 units are mounted close together: –10 to +50 °C +14 to +122 °F, if 8 to 16 units are mounted close together:
–10 to +45 °C +14 to +113 °F) (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F
Incandescent light: 3,000 ℓx at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3)
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3)
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Emitting element (modulated)
Red LED (Peak emission wavelength: 643 nm 0.025 mil)
Material
Enclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT
Connecting method
Cable length
Weight
Accessory
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
Voltage withstandability
Square Head
Type
Wide
Beam
ON-delay / OFF-delay timer, switchable either effective or ineffective
[Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms]
Incorporated
Emission frequency selection method (Note 2)
(Functions at emission frequency 1, 2 or 3)
Threaded
Type
Convergent
Reflective
Type
Incorporated
Ambient humidity
Earlier models
comparison
table
Narrow
Beam
4 digits (green) + 4 digits (red) LCD display
Emission amount setting function
Interference prevention
function
Emission frequency 1: 2.5 ms or less (factory default setting)
Emission frequency 2: 2.8 ms or less
Emission frequency 3: 3.2 ms or less
Emission frequency 4: 5.0 ms or less
Orange LED (lights up when the output is ON)
Fine sensitivity adjustment function
Timer function
How to read
Model No.
Super
Quality
PNP non-contact input
• Signal condition
High: +4 V to +V DC
(Sink current 0.5 to 3 mA)
Low: 0 to +0.6 V DC or Open
• Input impedance: 10 kΩ approx.
2-point teaching / Limit teaching / Full-auto teaching
Digital display
Choose
by shape/
application
Incorporated
Emission frequency 0: 250 µs or less (factory default setting)
Emission frequency 1: 450 µs or less
Emission frequency 2: 500 µs or less
Emission frequency 3: 600 µs or less
Operation indicator
Model
Fibers
NPN non-contact input
• Signal condition
High: +8 V to +V DC or Open
Low: 0 to +2 V DC
(Source current 0.5 mA or less)
• Input impedance: 10 kΩ approx.
Sensitivity setting
Fiber
Selection
Guide
Selectable either Light-ON or Dark-ON, at SET mode
Short-circuit protection
External input
Tough
Fiber
Connector (Note 4)
Total length up to 100 m 328.084 ft is possible with 0.3 mm , or more, cable.
2
Net weight: 15 g approx.
Gross weight: 35 g approx.
Net weight: 15 g approx.
Gross weight: 75 g approx.
Net weight: 15 g approx.
Gross weight: 35 g approx.
FC-FX-1
(Protection cover): 1 pc. (Note 6) FC-FX-1
FC-FX-1
(Protection cover): 1 pc. (Note 6) CN-14A-C2
(Protection cover): 1 pc. (Note 6)
(Connector attached cable, 2 m 6.562 ft long): 1 pc.
Net weight: 15 g approx.
Gross weight: 75 g approx.
FC-FX-1
(Protection cover): 1 pc. (Note 6)
CN-14A-C2
(Connector attached cable, 2 m 6.562 ft long): 1 pc.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to
different frequency values.
However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2.
3) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
4) Connector attached cable CN-14A-C2 is not attached to the models that have no “-CC2” at the end of the model Nos.
Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd.
(contact: SPHD-001T-P0.5, housing: PAP-04V-S).
5) Model Nos. having the suffix “-Z” are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C□.
6) Protection cover FC-FX-1 has been attached from production in July, 2011.
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
104
104
I/O CIRCUIT AND WIRING DIAGRAMS
New product
introduction
Tough
Fiber
FX-10□(-Z/-CC2)
NPN output type
I/O circuit diagram
Terminal arrangement diagram
Fiber
Selection
Guide
Terminal No.
Model
How to read
Model No
Earlier models
comparison
table
1
D
Sensor circuit
Choose
by shape/
application
+8 V
2
Tr
Threaded
Type
Square Head
Type
Cylindrical
Type
3
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Semi-custom
fibers
Output
3
External input
4
M8 plug-in connector type
Terminal No.
1
or
3
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Function
+V
2
Output
External input
4
0V
High (+8 V to +V DC, or open): Ineffective
Low [0 to +2 V DC (source current 0.5 mA or less)]: Effective
FX-10□P(-Z/-CC2)
PNP output type
I/O circuit diagram
Terminal arrangement diagram
Terminal No.
Connector type
Color code of cable with connector
1
3
D
*1
(White) External input
ZD
Tr
Terminal No.
(Brown) +V
100 mA max.
2
4
(Black) Output
(Blue) 0 V
Load
+
–
12 to 24 V DC
±10 %
Function
+V
1
2
Output
3
External input
4
0V
Users’ circuit
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor
M8 plug-in connector type
Terminal No.
1
* 1
Non-voltage contact or PNP open-collector transistor
Fiber
Dimensions
0V
Users’ circuit
Internal circuit
Fiber
Options
*1
(Blue) 0 V
2
Non-voltage contact or NPN open-collector transistor
Sensor circuit
Liquid Leak /
Liquid Detection
12 to 24 V DC
±10 %
* 1
Chemical / Oilresistant
Vacuumresistant
+
–
Function
+V
1
(White) External input
Retroreflective
Type
Heatresistant
Load
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor
Sleeve
Flat
Type
(Black) Output
Internal circuit
Fibers
Terminal No.
(Brown) +V
100 mA max.
ZD
4
Super
Quality
Connector type
Color code of cable with connector
or
High [ +4 V to +V DC (sink current 0.5 to 3 mA)]: Effective
Low (0 to +0.6 V DC, or open): Ineffective
3
Function
+V
2
4
Output
External input
0V
105
105
SENSING CHARACTERISTICS (TYPICAL)
FT-31W
250
9.843
ℓ
100
3.937
200
100
0
100
200
7.874 3.937
3.937 7.874
Left
Center
Right
Operating point ℓ (mm in)
FT-43
Parallel deviation
0
100
3.937
800
31.496
600
23.622
FX-101
Fiber
head
400
15.748
ℓ
L
Fiber
head
200
7.874
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
FT-S21W
150
5.906
FX-101
100
3.937
Fiber
head
ℓ
50
1.969
L
Fiber
head
400
15.748
FX-101
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
100
3.937
400
15.748
Fiber
head
ℓ
L
Fiber
head
0
Sensing field
• Horizontal direction
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
400
15.748
FX-101
L
Fiber
head
Left
0
20
0
20
0.787
0.787
Left
Center
Right
Operating point ℓ (mm in)
FDA269
Right
40
1.575
Setting distance L (mm in)
White
non-glossy
paper
200mm
7.874in
ℓ
FX-102
White
non-glossy
paper
200mm
7.874in
100
3.937
50
1.969
0
40
1.575
ℓ
1,000
39.370
L
Fiber
head
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
FX-101
ℓ
L
Fiber
head
Up
Down
20
0
20
0.787
0.787
Down
Center
Up
Operating point ℓ (mm in)
FDA269
200
0
200
7.874
7.874
Left
Center
Right
Operating point ℓ (mm in)
L
Fiber
head
Left
Right
FX-102
100
3.937
FX-101
50
1.969
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
FD-41W
40
1.575
8mm ℓ
0.315in
L
Fiber
head
200
0
200
7.874
7.874
Down
Center
Up
Operating point ℓ (mm in)
60
2.362
400
15.748
FX-102
100
3.937
FX-101
7.874in
Left
40
1.575
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Right
Fiber
Options
50
1.969
Semi-custom
fibers
20
0
20
0.787
0.787
Left
Center
Right
Operating point ℓ (mm in)
40
1.575
Fiber
Dimensions
FDA273
Reflective type
Thru-beam
Type
Retroreflective
Type
Reflective
Type
• Vertical direction
200
7.874
200
7.874
FX-102
FX-101
ℓ
White
non-glossy
paper
200mm
7.874in
L
Fiber
head
50
1.969
Left
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
FDA266
200mm
ℓ
L
Fiber
head
150
5.906
FDA272
100
3.937
White non-glossy paper
200
7.874
250
9.843
60
2.362
Small
Spot
Fiber
head
1,000
39.370
250
9.843
0
Flat
Type
2,000
78.740
0
Threaded
Type
Sleeve
FX-101
250
9.843
Super
Quality
Cylindrical
Type
Reflective type
FD-32GX FTA237
White non-glossy paper
200mm 7.874in
Fibers
Square Head
Type
Sensing field
ℓ
150
5.906
150
5.906
400
15.748
FX-102
0
400
15.748
400
15.748
Reflective type
FTA237
200
7.874
60
2.362
150
5.906
FX-102
Fiber
head
Sensing field
• Horizontal direction
• Vertical direction
150
5.906
2,000
78.740
0
FTA231
Reflective type
FTA232
400
15.748
3,000
118.110
250
9.843
200
7.874
0
• Vertical direction
Sensing field
600
23.622
Earlier models
comparison
table
4,000
157.480
FD-32G
FX-102
L
Thru-beam type
FTA229
FX-101
0
400
15.748
1,000
39.370
Setting distance L (mm in)
Setting distance L (mm in)
Setting distance L (mm in)
500
0
500
19.685
19.685
Left
Center
Right
Operating point ℓ (mm in)
Parallel deviation
FX-102
FD-41S
Setting distance L (mm in)
L
Fiber
head
How to read
Model No.
Fiber
head
FTA234
Parallel deviation
• Horizontal direction
800
31.496
200
7.874
40
1.575
ℓ
Fiber
head
ℓ
200
7.874
FT-A11
Thru-beam type
FT-S31W FTA236
250
9.843
50
1.969
Fiber
head
Choose
by shape/
application
FX-101
400
15.748
600
23.622
3,000
118.110
FX-101
Model
FX-102
600
23.622
FX-102
FX-102
200
7.874
0
1,000
39.370
Thru-beam type
FTA233
Parallel deviation
100
3.937
600
400
200
0
200
400
23.622 15.748 7.874
7.874 15.748
Left
Center
Right
Operating point ℓ (mm in)
4,000
157.480
400
15.748
1,000
39.370
L
Fiber
head
0
100
3.937
Setting distance L (mm in)
600
23.622
100
3.937
50
0
50
1.969
1.969
Left
Center
Right
Operating point ℓ (mm in)
Thru-beam type
FTA230
Parallel deviation
Setting distance L (mm in)
Setting distance L (mm in)
FX-102
800
31.496
0
Fiber
head
ℓ
200
7.874
1,000
39.370
1,000
39.370
1,000
39.370
L
Fiber
head
FX-101
400
15.748
FT-45X
1,200
47.244
0
ℓ
50
1.969
300
11.811
Thru-beam type
FTA235
Fiber
head
600
23.622
Setting distance L (mm in)
300
11.811
L
Fiber
head
FX-101
100
3.937
FX-102
Setting distance L (mm in)
Fiber
head
150
5.906
Tough
Fiber
Fiber
Selection
Guide
800
31.496
800
31.496
Setting distance L (mm in)
FX-101
200
7.874
FX-102
Thru-beam type
Parallel deviation
1,000
39.370
200
7.874
Setting distance L (mm in)
Setting distance L (mm in)
FX-102
300
11.811
0
Parallel deviation
Parallel deviation
400
15.748
FT-42W
Thru-beam type
Setting distance L (mm in)
Parallel deviation
FT-42S
Thru-beam type
Setting distance L (mm in)
Thru-beam type
Right
60
2.362
Setting distance L (mm in)
FT-31S
New product
introduction
Others
FX-102
150
5.906
FX-101
100
3.937
L
Fiber
head
50
1.969
0
60
2.362
White
non-glossy
paper
200mm
7.874in
ℓ
Up
Down
40
20
0
20
40
1.575 0.787
0.787 1.575
Down
Center
Up
Operating point ℓ (mm in)
FDA266
Amplifiers
FX-500
series
FX-100
series
60
2.362
INDEX
106
106
SENSING CHARACTERISTICS (TYPICAL)
60
2.362
Super
Quality
Square Head
Type
Cylindrical
Type
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Chemical / Oilresistant
Vacuumresistant
Semi-custom
fibers
FX-101
ℓ
L
Fiber
head
50
1.969
Left
Amplifiers
FX-500
series
FX-100
series
Right
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
150
5.906
FX-102
FX-101
100
3.937
L
Fiber
head
50
1.969
0
60
2.362
60
2.362
Up
Down
40
20
0
20
40
1.575 0.787
0.787 1.575
Down
Center
Up
Operating point ℓ (mm in)
500
19.685
400
15.748
400
15.748
FX-102
FX-101
L
Fiber
head
50
1.969
Left
Right
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
60
2.362
Sensing field
150
5.906
100
3.937
FX-102
FX-101
50
1.969
0
30
1.181
White non-glossy
paper
200mm 7.874in
ℓ
L
Fiber
head
Left
20
10
0
10
20
0.787 0.394
0.394 0.787
Left
Center
Right
Operating point ℓ (mm in)
INDEX
FDA275
Right
30
1.181
100
3.937
FX-101
Up
Down
0
60
2.362
White non-glossy
paper
200mm 7.874in
ℓ
L
Fiber
head
50
1.969
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
FDA276
FX-101
200
7.874
ℓ
L
Fiber
head
100
3.937
0
150
5.906
Left
60
2.362
150
5.906
ℓ
L
Fiber
head
100
3.937
0
150
5.906
150
5.906
Up
Down
100
50
0
50
100
3.937 1.969
1.969 3.937
Down
Center
Up
Operating point ℓ (mm in)
150
5.906
• Vertical direction
250
9.843
White
non-glossy
paper
200mm
7.874in
ℓ
FX-102
L
Fiber
head
50
1.969
Left
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
FDA267
FX-101
White
non-glossy
paper
200mm
7.874in
Reflective type
FDA268
FX-101
60
2.362
200
7.874
FDA268
100
3.937
0
FX-102
300
11.811
Right
100
50
0
50
100
3.937 1.969
1.969 3.937
Left
Center
Right
Operating point ℓ (mm in)
FD-S32W
200
7.874
100
3.937
White
non-glossy
paper
200mm
7.874in
300
11.811
200
7.874
FX-102
• Vertical direction
500
19.685
200
7.874
150
5.906
Reflective type
FDA270
Sensing field
• Horizontal direction
• Vertical direction
White non-glossy
paper
200mm 7.874in
ℓ
80
3.150
Sensing field
• Horizontal direction
250
9.843
FX-102
Right
40
0
40
1.575
1.575
Left
Center
Right
Operating point ℓ (mm in)
FD-62
250
9.843
150
5.906
Left
80
3.150
60
2.362
FDA265
L
Fiber
head
0
Reflective type
FDA265
Reflective type
FD-S33GW FDA276
Setting distance L (mm in)
Others
ℓ
250
9.843
Fiber
Dimensions
Reflective
Type
White
non-glossy
paper
200mm
7.874in
White
non-glossy
paper
200mm
7.874in
ℓ
FX-101
100
3.937
30
1.181
200
7.874
White
non-glossy
paper
200mm
7.874in
FX-102
200
7.874
Right
• Vertical direction
100
3.937
60
2.362
Thru-beam
Type
Left
20
10
0
10
20
0.787 0.394
0.394 0.787
Left
Center
Right
Operating point ℓ (mm in)
Reflective type
FDA274
150
5.906
0
Retroreflective
Type
30
1.181
Sensing field
• Horizontal direction
Setting distance L (mm in)
Fiber
Options
FX-101
50
1.969
White non-glossy
paper
200mm 7.874in
ℓ
L
Fiber
head
300
11.811
250
9.843
FD-64X
Liquid Leak /
Liquid Detection
FX-102
100
3.937
FDA271
FX-102
60
2.362
400
15.748
0
60
2.362
200
7.874
0
Retroreflective
Type
Heatresistant
Right
250
9.843
Setting distance L (mm in)
Small
Spot
Left
40
20
0
20
40
1.575 0.787
0.787 1.575
Left
Center
Right
Operating point ℓ (mm in)
Sensing field
• Horizontal direction
Sleeve
Flat
Type
L
Fiber
head
FD-61W
Threaded
Type
ℓ
50
1.969
0
Fibers
FX-101
100
3.937
Setting distance L (mm in)
Earlier models
comparison
table
150
5.906
White
non-glossy
paper
200mm
7.874in
Setting distance L (mm in)
How to read
Model No
FX-102
Reflective type
Sensing field
150
5.906
Setting distance L (mm in)
200
7.874
Choose
by shape/
application
Sensing field
Setting distance L (mm in)
Model
Setting distance L (mm in)
250
9.843
FD-61G
Reflective type
Setting distance L (mm in)
Sensing field
Fiber
Selection
Guide
FD-42GW
Reflective type
Right
60
2.362
Setting distance L (mm in)
FD-42G
Setting distance L (mm in)
Tough
Fiber
Setting distance L (mm in)
New product
introduction
White non-glossy paper
200mm
ℓ
200
7.874
150
5.906
FX-102
7.874in
L
Fiber
head
Up
Down
FX-101
100
3.937
50
1.969
0
60
2.362
40
20
0
20
40
1.575 0.787
0.787 1.575
Down
Center
Up
Operating point ℓ (mm in)
FDA267
60
2.362
107
107
Refer to the “Operation Guide” on our website for details pertaining to
operating instructions for the amplifier.
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Using in combination with the FX-300 / FX-410 series
• The FX-100 series does not use the horizontal
connectors that are used with the FX-300 / FX-410
series. Please note that horizontal connection cannot be
performed using a connector attached cable. In addition,
the optical communication function is not equipped on
the FX-100 series, so it is unable to perform interference
prevention for use with the FX-300 / FX-410 series.
If using the FX-100 series together with the FX-300 /
FX-410 series side-by-side, please set the same models
together in groups.
Mounting
How to mount the amplifier
Fit the rear part of the mounting
section of the amplifier on a 35 mm
1.378 in width DIN rail.
Press down the rear part of the
mounting section of the unit on the
35 mm 1.378 in width DIN rail and
fit the front part of the mounting
section to the DIN rail.
1
• Make sure that the power supply is OFF while adding or
removing the amplifiers.
• Note that if a voltage exceeding the reted range is applied,
or if an AC power supply is directly connected, the product
may get burnt or damaged.
• Note that short-circuit of the load or wrong wiring may burn
or damage the product.
• Do not run the wires together with high-voltage lines or
power lines, or put them in the same raceway. This can
cause malfunction due to induction.
• Verify that the supply voltage variation is within the rating.
• If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power
supply is connected to an actual ground.
• In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this product,
connect the frame ground (F.G.) terminal of the equipment
to an actual ground.
• Make sure to use the quick-connection cable (optional) for
the connection of the controller.
Extension up to total 100 m 328.084 ft is possible with 0.3
mm2 or more, cable. However, in order to reduce noise,
make the wiring as short as possible.
Operation indicator
(Orange)
ON key /
Setting value UP key
OFF key /
Setting value DOWN key
Digital display (Red)
(Incident light intensity)
Setting mode
• Setting mode appears after the MODE key is pressed for
2 sec. in RUN mode.
• Use M3 screws with washers
for mounting. The tightening
torque should be 0.5 N·m or
less.
Setting item Factory setting
Teaching
mode
Timer
operation
setting
Timer
delays
setting
Emission
amount
setting
Description
Threshold value can be set in 2-point teaching,
limit teaching, or full-auto teaching.
Output
operation
setting
M3 screw
with washer
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Convergent
Reflective
Type
Retroreflective
Type
MODE key
1
Note: Take care that if the front part is lifted without pushing the amplifier
forward, the hook on the rear portion of the mounting section is likely
to break.
Model
Chemical / Oilresistant
Digital display (Green)
(Threshold value)
2
Fiber
Selection
Guide
Wide
Beam
35 mm 1.378 in width DIN rail
How to remove the amplifier
Push the amplifier forward.
Lift up the front part of the
amplifier to remove it.
Tough
Fiber
Wiring
Part description
2
New product
introduction
[Dark-ON]
[Without timer]
Light-ON or Dark-ON can be set.
Without timer, ON delay timer, or OFF delay
timer can be set.
When setting ON delay timer or OFF delay
[ON-delay timer: 10 ms] timer in the timer operation setting mode, timer
delays can be set.
• When timer is not set, this mode is not
[OFF-delay timer: 10 ms] displayed.
*
[Level 3]
Emission
frequency
setting
1 (Response time:
2.5 ms or less)
* Indicated as“
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
In case incident light intensity is saturated,
emission amount can be reduced.
Amplifiers
FX-101□
0 (Response time:
250 µs or less)
FX-102□
Heatresistant
FX-500
series
When using the fiber heads in parallel,
interference can be prevented by setting
different emission frequency. However, when
emission frequency 0 is set, interference
cannot be prevented. Response time
corresponds to emission frequency.
FX-100
series
”before production in November 2007.
INDEX
108
108
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
PRECAUTIONS FOR PROPER USE
PRO mode
• PRO mode appears after the MODE key is pressed for 4
sec. in RUN mode.
Setting item Factory setting
Shift
setting
How to read
Model No
Earlier models
comparison
table
External
input
setting
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Threshold
value-storing
setting mode
(Note 2)
Threshold
value
follow-up
cycle
setting
(Note 3)
GETA
function
setting
(Note 4, 5)
[OFF]
[OFF]
[OFF]
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
ECO
setting
Digital display
inversion
setting
Threshold
value
margin
setting
Thru-beam
Type
Setting
copy
Retroreflective
Type
Reset
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Description
Shift amount can be selected from 0 to 80 % in
the limit teaching. Select 0 % when it is desired
[Shift amount 15 %] to set the present incident light intensity as a
threshold value.
External input can be selected from emission
halt, limit teaching [+], limit teaching [-], full-auto
teaching, ECO (Note 1), 2-point teaching or
emission amount test. When setting the incident
”, output turns ON /
light intensity test “
OFF every 100ms when the rate of incident
[Emission halt]
light intensity and threshold value is less than
half of the set shift amount (for example, when
the rate of incident light intensity and threshold
value is within ±10 % for 20 % of shift amount)
at external input.
[OFF]
[OFF]
[OFF]
[NO]
[NO]
Threshold value set at the limit teaching,
full-auto teaching or 2-point teaching by
external input is stored. When selecting
Auto in the emission amount setting
mode, the set emission amount level is
also stored.
When incident light intensity exceeds threshold
value, this mode can change the threshold value
with each set cycle depending on variations of the
incident light intensity. The follow-up shift amount
is same as the one set in the shift setting mode.
However, the threshold value is not stored.
Variations can be reduced by correcting the
present incident light intensity in each amplifier
to a target value. Target value to offset incident
light intensity can be selected from 0 to 2,000
by 100 unit each. For example, if the target
value is set to 2,000 when the incident light
intensity is 1,500, the incident light intensity
becomes 2,000.
It is possible to light up / turn off the digital
display. When ECO setting mode is ON, the
display turns off in 20 sec. approx. in RUN
mode. To light up the display again, press any
key for 2 sec. or more.
Digital display can be inverted.
Margin for threshold value to the present
incident light intensity can be checked. When
there is no margin, it is possible to make the
digital display blink.
: Set to “OFF”: does not function.
: Green blinks.
: Red blinks.
: Red and green blink.
: When conducting limit teaching or 2-point
teaching by external input, in case the rate of reference
incident light intensity and threshold value after teaching
is 200% or more, or in case it is less than half of the shift
amount, output turns ON / OFF every 100 ms. (Note 6)
The settings of the master side amplifier can
be copied to the slave side amplifier.
For details, refer to “Setting copy function”.
Returns to default settings (factory settings.)
Notes: 1) When ECO is selected at the external input setting mode, key
operation on the main body is invalid during external input.
”, “
”,
2) This mode is not indicated unless any of “
” or “
” is set at the external input setting mode.
“
(Incorporated from production in December 2007.)
3) If the incident light intensity becomes “300” or less, the follow-up
operation stops. In that condition, threshold value [digital display
(green)] blinks. This function can be used when thru-beam type or
retroreflective type fiber is applied to this product. If reflective type fiber
is applied, the function cannot be used depending on use conditions.
4) If MODE key is pressed in RUN mode when GETA function is
used, the incident light intensity before setting GETA function is
displayed on the red digital display for 2 sec. approx.
5) When GETA function is used in saturation of incident light intensity
(4,000 or more,) “
” is indicated on the red digital display.
Correction value is up to 4,000.
6) This mode does not operate unless any of “
”, “
” or
“
” is set at the external input setting mode.
(Incorporated from production in December 2007.)
Refer to the “Operation Guide” on our website for details pertaining to
operating instructions for the amplifier.
Setting copy function
• This can copy the settings of the master side amplifier to
the slave side amplifier.
• Be sure to use the setting copy function between the
identical models (Between FX-101□ models or FX-102□
models).
This function cannot be used between different
models.
• Only one sensor can be connected on slave side with a
master side sensor for the setting copy function.
• Threshold value, output operation setting, timer
operation setting, timer setting, light-emitting amount
setting, shift setting, external input setting, threshold
value margin setting, ECO setting, digital display
inversion setting, and threshold value margin setting
can be copied.
Set the setting copy mode of the master side amplifier to
“Copy sending ON”, and press the MODE key so that
“
” is shown on the digital display and the
sensor is in copy ready state. For the setting method,
refer to “Operation guide”.
Turn off the master side amplifier.
Connect the master side amplifier with the slave side
amplifier as shown below.
Color code of cable with connector
Master side amplifier
(Brown) +V
(Black) Input
(White) External input
+
–
12 to 24V DC
±10 %
(Blue) 0 V
Slave side amplifier
(Brown) +V
(Black) Input
(White) External input
(Blue) 0 V
Turn on the master side amplifier and the slave side
amplifier at the same time. (Note)
“
” is shown on the green digital display of the master
side amplifier and 4-digit code is shown on the red
digital display of it, then the copying starts. During copy
communication, “
” is shown on the green digital
display of the slave side amplifier, and the ongoing copy
communication indicator (“
”→“
”→“
”→
”→“
”→“
”→“
”→“
”) is displayed on
“
the red digital display.
When the copying is completed, “
” is shown on the
green digital display of the slave side amplifier, while the
4-digit code (the same code as the master side amplifier)
is shown on the red digital display of it.
Turn off the power of the master side amplifier and the
slave side amplifier and disconnect the wire.
* If copying the settings to another amplifier repeatedly, follow the steps
to .
Note: Take care that if the power is not turned on at the same time, the
setting contents may not be copied.
W
hile the slave side amplifier is disconnected, turn on
the power of the master side amplifier.
Press the MODE key for 2 sec. approx.
109
109
Refer to the “Operation Guide” on our website for details pertaining to
operating instructions for the amplifier.
PRECAUTIONS FOR PROPER USE
Others
Code setting function
• The code setting function makes it possible to set the
output operation, timer operation, amount of light emitted,
frequency of light emitted, ECO setting, external input,
and amount of shift by selecting a code of one’s choice.
• While in the RUN Mode, pressing and holding both
the ON key ( ) and OFF key ( ) simultaneously for 4
seconds will switch to the code setting function.
1st digit
Output
Timer
operation (Note 1)
2nd digit
4th digit
Emission
External
amount
ECO
input
setting
(Note 2) FX-101□ FX-102□
Shift
(Note 1)
5%
non
0
1
Emission
halt
ond 10 ms
1
2
Limit
teaching [+]
2
3
Level 3
(OFF)
D-ON
3rd digit
Emission
frequency
ond 40 ms
3
ofd 10 ms
OFF Limit
teaching [-]
Full-auto
teaching
4
10 %
15 %
20 %
No.
Output operation
Timer
Emission amount setting (Note)
D-ON
non
D-ON
non
Level 2 (ON)
D-ON
ofd 10 ms
Level 3 (OFF)
D-ON
ofd 10 ms
Level 2 (ON)
D-ON
ofd 40 ms
Level 3 (OFF)
D-ON
ofd 40 ms
Level 2 (ON)
D-ON
ond 10 ms
Level 3 (OFF)
D-ON
ond 10 ms
Level 2 (ON)
D-ON
ond 40 ms
Level 3 (OFF)
D-ON
ond 40 ms
Level 2 (ON)
L-ON
ond 40 ms
Level 2 (ON)
L-ON
ond 40 ms
Level 3 (OFF)
L-ON
ond 10 ms
Level 2 (ON)
L-ON
ond 10 ms
Level 3 (OFF)
L-ON
ofd 40 ms
Level 2 (ON)
L-ON
ofd 40 ms
Level 3 (OFF)
L-ON
ofd 10 ms
Level 2 (ON)
L-ON
ofd 10 ms
Level 3 (OFF)
L-ON
non
Level 2 (ON)
L-ON
non
Level 3 (OFF)
Difference between previous model and upgraded one
• For upgraded ones (production in and after December
2007), “P” is marked near the beam-emitting inlet.
Previous ones have no marking. Appearance and
functions have been changed.
“P” indication
Beam-emitting inlet
ofd 40 ms
0
1
ECO
25 %
non
1
2
Emission
halt
30 %
ond 10 ms
2
3
Limit
teaching [+]
35 %
ond 40 ms
3
4
Limit
teaching [-]
40 %
ofd 10 ms
0
1
Full-auto
teaching
45 %
ofd 40 ms
1
2
ECO
50 %
2
3
2-point
teaching
Level 3 (OFF)
Note: Until production in November 2007, OFF or ON was selectable. The
emission amount of Level 2 (ON) is about 40% of that of Level 3
(OFF).
Fiber
Selection
Guide
Model
Choose
by shape/
application
Earlier models
comparison
table
Quick setting function
• The quick setting function makes it possible to set
the content of the SET Mode (output operation, timer
operation, amount of light emitted, and frequency of light
emitted) simply by selecting a setting number.
• While in the RUN Mode, pressing and holding both
the ON key ( ) and OFF key ( ) simultaneously for 2
seconds will switch to the quick setting function.
Tough
Fiber
How to read
Model No.
Code
• Our products have been developed / produced for
industrial use only.
• Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
• Take care that the product is not directly exposed
to fluorescent lamp from a rapid-starter lamp, a high
frequency lighting device or sunlight etc., as it may affect
the sensing performance.
• This product is suitable for indoor use only.
• Avoid dust, dirt, and steam.
• Take care that the product does not come in contact with
oil, grease, organic solvents, such as thinner, etc., strong
acid or alkaline.
• This product cannot be used in an environment
containing inflammable or explosive gases.
• Never disassemble or modify this product.
• EEPROM is adopted to this product. It is not possible to
conduct teaching 100 thousand times or more, because
of the EEPROM’s lifetime.
New product
introduction
Level 2
(ON)
L-ON
ON
Level 1
OFF
3
0
4
Incident light
intensity test
1
2-point
teaching
ON
1
2
Incident light
intensity test
Auto
2
3
3
4
Notes: 1) When the present setting is out of the code setting range, “ ” is shown.
When “ ” is selected, the set content of the digit is not changed.
2) Until production in November 2007, OFF or ON was selectable.
The emission amount of Level 2 is about 40% of that of Level 3.
The emission amount of Level 1 is about 20% of that of Level 3.
3) The factory setting is “
”.
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
110
110
New product
introduction
Tough
Fiber
FX-101□ FX-102□
Fiber
Selection
Guide
0.8
0.031
Model
Choose
by shape/
application
How to read
Model No
Refer to p.48~ for details of fiber dimensions.
The CAD data in the dimensions can be downloaded from our website.
DIMENSIONS (Unit: mm in)
Amplifier
48 1.890
30 1.181
20
13.2
0.787
0.520
6 0.236
FX-101(P)-Z FX-102(P)-Z
Amplifier
10.85
6 0.236
2.7
0.106
0.7
0.028
0.8
0.031
OFF key / Setting value DOWN key
ON key / Setting value UP key
MODE key
4.1
Operation indicator (Orange) 0.161
Digital display (Green, Red)
48 1.890
30 1.181
20
13.2
0.787
0.520
6 0.236 6 0.236 0.427
2.7
0.106
0.7 0.028
OFF key / Setting value DOWN key
ON key / Setting value UP key
MODE key
4.1
Operation indicator (Orange) 0.161
Digital display (Green, Red)
Earlier models
comparison
table
0.75 0.030
Fibers
Super
Quality
Threaded
Type
66.2
2.606
9
0.354
7
0.276
Cylindrical
Type
0.394
10
6.5
0.256
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
3 0.118
50 1.969
35 1.378
65.5 2.579
14.5
0.571
3.2
2 0.126
6.5
0.256
0.079
ø3.2 ø0.126
3.2
0.126
Chemical / Oilresistant
Heatresistant
Vacuumresistant
9.25
0.364
ø6.2 mm ø0.244 in
spot facing, 3 0.118 deep
Liquid Leak /
Liquid Detection
Semi-custom
fibers
6.2 mm 0.244 in
spot facing, 3 0.118 deep
3.2
0.126
ø3.2 ø0.126
0.8
0.031
Material: PBT
50 1.969
35 1.378
65.5 2.579
0.7
0.028
OFF key / Setting value DOWN key
ON key / Setting value UP key
MODE key
1
0.039
5.5 0.217
End plate (Optional)
Suitable for 35 mm 1.378 in width DIN rail
9
0.354
9
0.354
0.8
0.031
10 30
0.394 1.181
8.1
0.319
1.1
0.043
7 0.276 4
0.157
10 0.394
MS-DIN-E
3.2
8.1
0.126 0.319
2
0.079
6 6
47 1.850
0.236 0.236
29 1.142
2.7
12.2
20 0.787
0.106
0.480
4.1
Operation indicator (Orange) 0.161
Digital display (Green, Red)
1
0.039
24.5
0.965
35
1.378
5
0.197
14.5
0.571
Previous dimensions (production before November 2007)
11.5
0.453
4
0.157
Fiber
Options
1
0.039
15
0.591
ø3.2
ø0.126
Note: The protection cover has been attached from the production at July, 2011.
7.2 mm 0.283 in
spot facing, 4 0.157 deep
Retroreflective
Type
10 30
0.3941.181
3 0.118
Suitable for 35 mm 1.378 in width DIN rail
Amplifier mounting bracket (Optional)
ø7.2 mm ø0.283 in
spot facing, 4 0.157 deep
4 0.157
10
ø6.5
ø0.256
0.8
0.031
0.394
Note: The protection cover has been attached from the production at July, 2011.
MS-DIN-4
7
0.276
8.1
0.319
ø3.2
ø0.126
1
0.039
6 0.236
1.1
0.043
2
0.079
10 30
0.394 1.181
0.8
0.031
4 0.157
66.2
2.606
9
0.354
2 0.079
6 0.236
1.1
0.043
Square Head
Type
0.75 0.030
ø3.2
ø0.126
13.5
0.531
3.2
2 0.126
0.079
3
0.118
50 1.969
35 1.378
64.5 2.539
Suitable for 35 mm 1.378 in width DIN rail
CN-14A-C□ CN-14A-R-C□
Connector attached cable (Optional)
CN-14A-C2 is attached FX-101(P)-CC2 / FX-102(P)-CC2
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
2.75 0.108
3
0.118
15
0.591
M3 (Iength 18 mm 0.709 in) pan head screws
60
2.362
Amplifiers
FX-500
series
FX-100
series
INDEX
M3 square nut
5.6
0.220
24.7
0.972
Reflective
Type
Others
3 0.118
1.6
0.063
Material: Polycarbonate
32
1.260
4
0.157
Suitable for 35 mm 1.378 in width DIN rail
8
0.315
( )
L
35
(1.378
)
50
(1.969
)
(0.3158 )
ø3.7 ø0.146 cable
• Length L
Model No.
CN-14A(-R)-C1
CN-14A(-R)-C2
CN-14A(-R)-C3
CN-14A(-R)-C5
Length L
1,000 39.370
2,000 78.740
3,000 118.110
5,000 196.850
111
112
112
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
INDEX
C
CN-14A
CN-14A-C1
FX-100 Connector
CN-14A-C2
FX-100
CN-14A-C3
CN-14A-C5
CN-14A-R-C1
CN-14A-R-C2
CN-14A-R-C3
CN-14A-R-C5
CN-71-C1
CN-71-C2
CN-71-C5
CN-72-C1
CN-72-C2
CN-72-C5
CN-73-C1
CN-73-C2
CN-73-C5
CN-74-C1
CN-74-C2
CN-74-C5
Connector Attached Cable
FX-100 Connector
p.102
p.102/p.110
p.102/p.103/
p.110
p.102/p.110
Attached Cable (Flexible)
FX-500
Quick-connection Cable
p.74/p.96
F
Fiber Bender
Retroreflective
Type
FC-FX-1
FX-100 Protection Cover
Chemical / Oilresistant
FD-30
Super Quality Fiber
p.11/p.39/p.56/
p.85
Heatresistant
FD-31
FD-31W
Threaded Type Fiber
p.13/p.39/p.56/
p.85
FD-32G
FD-32GX
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
Threaded /
Small Spot Type Fiber
p.102/p.103
p.13/p.23/p.39/
p.56/p.85/p.105
p.13/p.32/p.39/
p.56/p.86/p.105
Super Quality Fiber
p.11/p.39/p.56/
p.86
FD-41
Threaded Type Fiber
p.13/p.39/p.56/
p.86
Sleeve Fiber
FD-41SW
p.19/p.39/p.56/
p.86/p.105
p.19/p.39/p.56/
p.86
FD-41W
Threaded Type Fiber
p.13/p.39/p.56/
p.86/p.105
FD-42G
FD-42GW
Threaded /
Small Spot Type Fiber
p.13/p.23/p.39/
p.57/p.86/p.106
FD-60
FD-61
Super Quality Fiber
Threaded Type Fiber
FD-61G
FX-500
series
FD-61S
FX-100
series
FD-61W
FD-62
Sleeve Fiber
Threaded Type Fiber
FD-64X
INDEX
p.18/p.45/p.66
FD-40
FD-41S
FD-A16
FD-AL11
p.17/p.19/p.39/
p.58/p.88
FD-EG30
Threaded /
Small Spot Type Fiber
p.13/p.23/p.39/
p.58/p.88
FD-EG30S
Sleeve Fiber
p.19/p.39/p.59/
p.88
FD-EG31
Threaded /
Small Spot Type Fiber
p.13/p.23/p.39/
p.59/p.88
Liquid Leak /
Liquid Detection Fiber
p.35/p.39/p.59
FD-F4
FD-F41
FD-F41Y
FD-F71
FD-F8Y
FD-FA93
FD-H13-FM2
FD-H18-L31
FD-H20-21
FD-H20-M1
FD-H25-L43
Wide Beam Fiber
Heat-resistant Fiber
p.31/p.40/p.60/
p.88
FD-H25-L45
p.31/p.40/p.60/
p.89
FD-H30-KZ1V
Vacuum-resistant Fiber
FD-H30-KZ1V-S
p.33/p.44
p.32/p.40/p.61
FD-H30-L32
p.31/p.40/p.61/
p.89
FD-H30-L32V-S
FB-1
Liquid Leak /
Liquid Detection
Cylindrical / Sleeve Fiber
FD-H30-L32V
Convergent
Reflective
Type
Vacuumresistant
FD-E13
FD-E23
FD-H35-20S
FD-H35-M2
FD-H35-M2S6
FD-HF40Y
FD-L10
FD-L11
FD-L12W
FD-L20H
FD-L21
FD-L21W
FD-L22A
FD-L23
FD-L30A
FD-L31A
Heat-resistant Fiber
p.33/p.44
Vacuum-resistant Fiber
Heat-resistant Fiber
p.31/p.40/p.61/
p.89
Liquid Leak / Liquid Detection Fiber
p.35/p.40/p.61
p.26/p.40/p.62/
p.89
Convergent Reflective Type
Fiber
p.26/p.40/p.62/
p.90
p.26/p.40/p.62/
p.90
p.26/p.40/p.63/
p.90
FD-L32H
FD-R31G
FD-R32EG
FD-R33EG
FD-R34EG
FD-R41
p.32/p.40/p.61/
p.89
Square Head /
Small Spot Type Fiber
p.15/p.23/p.40/
p.63
Square Head type Fiber
p.15/p.40/p.63
FD-R60
Threaded Type Fiber
p.11/p.39/p.57/
p.86
p.13/p.40/p.63/
p.90
FD-R61Y
p.13/p.39/p.57/
p.87
Square Head / Chemical /
Oil-resistant Fiber
p.15/p.29/p.40/
p.91
FD-S21
Cylindrical Fiber
p.13/p.39/p.57/
p.87/p.106
p.17/p.40/p.63/
p.91
FD-S30
Super Quality Fiber
p.11/p.40/p.64/
p.91
p.19/p.39/p.57/
p.87
p.13/p.39/p.57/
p.87/p.106
p.13/p.39/p.58/
p.87/p.106
p.25/p.39/p.58/
p.87
FD-S31
FD-S32
FD-S32W
FD-S33GW
Cylindrical Fiber
FD-S60Y
Chemical / Oil-resistant
Fiber
p.17/p.40/p.64/
p.91
p.17/p.41/p.64/
p.91/p.106
p.29/p.41/p.64/
p.91
113
113
INDEX
FD-V30
FD-V30W
New product
introduction
Sleeve Fiber
p.19/p.41/p.64/
p.92
FD-V50
p.19/p.41/p.65/
p.92
FD-Z20HBW
p.21/p.41/p.65/
p.92
FD-Z20W
FD-Z40HBW
FD-Z40W
Flat Type Fiber
FD-Z50HW
Narrow Beam Fiber
FDP-1000
FDP-1500
FDP-500
FDP-N1000
FDP-N1500
FDP-N500
FR-KZ22E
FR-KZ50E
FR-KZ50H
Protective Tube
(For Reflective Type Fiber)
p.21/p.41/p.65/
p.92
p.24/p.41/p.65/
p.92
p.45/p.67
p.24/p.27/p.38/
p.55/p.84
Narrow Beam /
Retroreflective Type Fiber
p.24/p.27/p.38/
p.55/p.85
FR-Z50HW
p.24/p.27/p.38/
p.55/p.85
FT-140
Threaded Type Fiber
p.12/p.36/p.48/
p.79
FT-30
Super Quality Fiber
p.11/p.36/p.48/
p.79
FT-31
Threaded Type Fiber
p.12/p.36/p.48/
p.79
FT-31S
Sleeve Fiber
p.19/p.36/p.48/
p.79/p.105
FT-31W
Threaded Type Fiber
p.12/p.36/p.48/
p.79/p.105
Super Quality Fiber
p.11/p.36/p.48/
p.79
FT-42
Threaded Type Fiber
p.12/p.31/p.36/
p.48/p.79
FT-42S
Sleeve Fiber
p.19/p.36/p.48/
p.79/p.105
FT-40
FT-42W
FT-43
Threaded Type Fiber
p.12/p.36/p.48/
p.79/p.105
FT-45X
p.12/p.36/p.49/
p.79/p.105
FT-A11
p.25/p.36/p.49/
p.79/p.105
FT-A11W
p.25/p.36/p.49/
p.79
FT-A32
FT-A32W
FT-AL05
FT-E13
FT-E23
FT-F93
Wide Beam Fiber
Cylindrical / Sleeve Fiber
Liquid Leak / Liquid Detection Fiber
FT-H20-J20
p.30/p.36/p.50/
p.80
FT-H20-J30
p.31/p.44
FT-H20-J30-S
FT-H20-J50
FT-H20-J50-S
FT-H20-M1
FT-H20-VJ50
Heat-resistant Fiber
FT-H30-M1V-S
p.31/p.44
How to read
Model No.
p.31/p.44
p.30/p.36/p.50/
p.80
p.33/p.44
Vacuum-resistant Fiber
p.32/p.36/p.50/
p.80
p.30/p.36/p.50/
p.81
FT-HL80Y
Chemical / Oil-resistant
Fiber
p.29/p.36/p.50/
p.81
FT-J8
Fiber for Atmospheric Side
p.33/p.44/p.66
FT-KS40
FT-KV26
FT-KV40
FT-KV40W
Narrow Beam Fiber
p.24/p.36/p.51/
p.81
FT-L80Y
Chemical / Oil-resistant
Fiber
p.29/p.36/p.51/
p.81
FT-R31
Square Head Type Fiber
p.15/p.36/p.51
Threaded Type Fiber
p.12/p.36/p.51/
p.81
Square Head Type Fiber
p.14/p.15/p.36/
p.51/p.81
Square Head / Chemical /
Oil-resistant Fiber
p.15/p.29/p.37/
p.52/p.82
FT-S11
Cylindrical Fiber
p.16/p.37/p.52/
p.82
FT-S20
Super Quality Fiber
p.11/p.37/p.52/
p.82
FT-S21
p.16/p.19/p.36/
p.49/p.80
FT-S31W
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Cylindrical Fiber
Super Quality Fiber
Cylindrical Fiber
p.16/p.37/p.52/
p.82/p.105
p.11/p.37/p.52/
p.82
p.16/p.37/p.52/
p.82/p.105
p.16/p.37/p.52/
p.82
FT-V23
p.19/p.37/p.52/
p.82
Sleeve Fiber
FT-V25
FT-V30
Fiber
Options
Semi-custom
fibers
p.16/p.37/p.52/
p.82
FT-S32
FT-V24W
Fibers
p.15/p.37/p.51
FT-S21W
FT-S30
Earlier models
comparison
table
p.31/p.44
p.30/p.36/p.50/
p.80
Heat-resistant Fiber
FT-R41W
FT-R42W
FT-R43
FT-R44Y
FT-R60Y
Model
Choose
by shape/
application
FT-H35-M2
FT-H35-M2S6
FT-R40
Fiber
Selection
Guide
p.30/p.36/p.50/
p.80
p.30/p.36/p.50/
p.80
FT-H20-VJ50-S
FT-H20-VJ80
FT-H20-VJ80-S
FT-H20W-M1
FT-H30-M1V
Tough
Fiber
p.31/p.44
FT-H20-J20-S
p.25/p.36/p.49/
p.80
p.35/p.36/p.49
p.30/p.36/p.50/
p.80
FT-H13-FM2
p.19/p.37/p.53/
p.82
p.19/p.37/p.53/
p.83
FT-V40
Cylindrical Fiber
p.16/p.37/p.53/
p.83
FT-V80Y
Chemical / Oil-resistant
Fiber
p.29/p.37/p.53/
p.83
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
114
114
New product
introduction
Tough
Fiber
Fiber
Selection
Guide
Model
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oilresistant
Heatresistant
Vacuumresistant
Liquid Leak /
Liquid Detection
Fiber
Options
Semi-custom
fibers
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
INDEX
FT-Z20HBW
FT-Z20W
FT-Z30
FT-Z30E
FT-Z30EW
FT-Z30H
FT-Z30HW
FT-Z30W
FT-Z40HBW
FT-Z40W
Flat Type Fiber
FT-Z802Y
Chemical / Oil-resistant
Fiber
FTP-500
FTP-1000
FTP-1500
FTP-N500
FTP-N1000
FTP-N1500
Protective Tube
(For Thru-beam Type Fiber)
FV-BR1
Photo-terminal for
Vacuum-resistant Fiber
p.33/p.44/p.66
Vacuum-resistant Expansion Lens
Vacuum-resistant Side-view Lens
p.33/p.42/p.66
FV-LE1
FV-SV2
FX-101
FX-101-CC2
FX-101P
FX-101P-CC2
FX-102
FX-102-CC2
FX-102P
FX-102P-CC2
FX-501
FX-501P
FX-502
FX-502P
FX-505-C2
FX-505P-C2
FX-AT15A
FX-AT2
FX-AT3
FX-AT4
FX-AT5
FX-AT6
FX-CT2
FX-CT3
FX-LE1
FX-LE2
FX-MB1
FX-MR1
FX-MR2
FX-MR3
FX-MR5
FX-MR6
FX-MR7
FX-MR8
FX-MR9
FX-SV1
M
MS-AJ1-F
MS-AJ2-F
MS-DIN-2
MS-DIN-4
p.20/p.37/p.53/
p.83
MS-DIN-E
End Plate
MS-EX3
FX-MR2 Mounting Bracket
MS-FD-2
p.20/p.37/p.54/
p.84
p.29/p.37/p.54/
p.84
p.45/p.66
MS-FD-3
MS-FD-F7-1
MS-FD-F7-2
MS-FX-01Y
MS-FX-02Y
MS-FX-03Y
MS-FX-YF
R
RF-003
Digital Fiber Sensor
FX-100 series
Digital Fiber Sensor
FX-500 series
p.102/p.103/
p.104/p.110
p.74/p.76/p.77/
p.96
p.74/p.76/p.78/
p.96
Fiber Single-core Holder
Fiber Attachment
Fiber Cutter
p.45
p.44/p.67
p.44
Lens for Thru-beam Type
Fiber
p.42/p.67
FX-500 Fiber Amplifier Protection Seal
p.75/p.76
p.23/p.43/p.67
Lens for Reflective Type
Fiber
Square Head Type M3,
Reflective Type Fiber &
Spot Lens
Side-view Lens for
Thru-beam Type Fiber
Universal Sensor Mounting
Stand
FX-500 Amplifer Mounting Bracket
FX-100 Amplifer Mounting Bracket
p.23/p.43/p.68
p.42/p.69
p.45
p.75/p.96
p.102/p.110
RF-13
RF-210
RF-220
RF-230
Fiber Mounting Bracket
p.74/p.96/
p.102/p.110
p.69
p.33/p.44/p.69
p.69
FD-F71 SUS Mounting Bracket
FD-F71 PVC Mounting Bracket
Liquid Inflow Prevention Joint
Protective Tube Extension Joint
Fiber Mounting Joint
Joint Internal Ferrulre
FR-KZ50E/KZ50H
Exclusive Reflector
p.35
p.35/p.45
p.44/p.69
Reflective Tape
Reflector
p.45/p.69
115
116
Communication Unit for Open Network
The digital sensor can be connected directly
to the 3 types of open network!
Other types of analog input sensors can also be connected!
Fiber Sensor Guide Book
Scattered digital sensors can be centrally managed and set through an open network.
Applicable
Digital Sensor
Digital Fiber Sensor
GA-311
DPS-400
DPH-100
Digital Laser Sensor
Digital Pressure Sensor
GH series
LS series
FX-500
Please contact ..........
Panasonic Industrial Devices SUNX Co., Ltd.
All Rights Reserved
No. CE-FIBERGUIDE-1-7 June, 2014
Specifications are subject to change without notice.
Panasonic Industrial Devices SUNX Co., Ltd. 2014
Printed in Japan