0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FP0-SL1

FP0-SL1

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    Communications Module DIN Rail

  • 数据手册
  • 价格&库存
FP0-SL1 数据手册
FP0 Programmable Controllers ARCT1B164E 0 ZERO Suitable for Installation Virtually Anywhere Actual size: W30 × H90 × D60 (mm) W1.181 × H3.543 × D2.362 (inch) These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Please contact .......... Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.nais-e.com/ I/O 10 points/14 points Relay output, terminal block type ( ) ( I/O 16 points Transistor output type ) ( I/O 32 points Transistor output type ) All Rights Reserved © 2006 COPYRIGHT Matsushita Electric Works, Ltd. Specifications are subject to change without notice. Printed in Japan.               Excellent space-saving design! 25 mm 105 mm .984 inch 4.134 inch Control unit Expansion unit Expansion unit Expansion unit Actual size image A terminal block type and a connector type are available. Both can be detached for easy wiring. ● Terminal block ● Connector ● MIL connector Terminal block type (European type, made by Phoenix Contact): Installation of electric wires having a cross section of 0.2 to 1.25 mm2 is possible without crimp terminals. Connector type (made by Molex): Ideal for installation during mass production. Installation of electric wires having a cross section of 0.2 to 0.75 mm2 is available Wire-press sockets are attached to the units with 16 or 32 I/O points. Installation of electric wires having a cross section of 0.2 to 0.3 mm2 is possible without stripping the wire cover. Available for: FP0-C10RS, C10CRS, C14RS, C14CRS, E8RS, E8YRS, E16RS Available for: FP0-C10RM, C10CRM, C14RM, C14CRM, E8RM, E16RM Available for: FP0-C16T, C16CT, C32T, C32CT, T32CT, E8X, E8YT, E16X, E16YT, E16T,E32T Wide variety of intelligent units ● Analog unit ● Thermocouple unit Analog I/O, A/D conversion, and D/A conversion units are available. Up to three units can be connected, allowing multi-channel analog control. Total accuracy: ± 0.8 °C (K/J/T range). Two types are available: 4-ch/8-ch types. Up to three units can be connected, allowing highaccuracy multi-point temperature control of a maximum of 24 channels. 90 mm 3.543 inch Input/Output terminals Control unit with 14 I/O points Control unit with 32 I/O points + 3 expansion units with 32 I/O points = 128 I/O points (Maximum allowable number of I/O points) EEPROM is used as the program memory. Program rewriting is possible even when running! Tool port Communications with the "Control FPWIN GR" software for programming from a personal computer is possible with only one cable. Available for: FP0-A21, FP0-A80, FP0-A04V, FP0-A04I Available for: FP0-TC4, FP0-TC8 ● CC-Link slave unit ● I/O link unit Supports CC-Link, which is an open network. Reading/Writing of fourword data through a maximum of 16 input and 16 output points. A link unit to enable FP0 to serve as a slave station of MEWNET-F (remote I/O system). Available for: FP0-CCLS Available for: FP0-IOL ● S-LINK control unit ● Power supply unit Can be directly connected to the SLINK wire-saving system and control up to 64 input and 64 output points. * S-LINK is a trademark of SUNX Limited. A power supply unit having the same height and depth as that of FP0. Input: 100 to 240 V AC universal. Output: 24 V AC up to 0.7 A Available for: FP0-SL1 Available for: FP0-PSA4 ● Rewriting in RUN mode Programs can be rewritten for debugging or activation adjustments during the operation of FP0. ● No backup battery required From 10 I/O points EEPROM is used as the program memory. Programs and device data can be stored without backup batteries, ensuring safe use in mass-produced machines. Up to 128 I/O points The control unit width is only 25 mm .984 inch*. Only 105 mm 4.134 inch even in combination with expansion units having a maximum of 128 I/O points * The width of the control unit with 32 I/O points and the S-LINK control unit is 30 mm 1.181 inch. The control unit can fit in your pocket: W 25 × H 90 × D 60 mm W .984 × H 3.543 × D 2.362 inch The number of I/O points can be expanded up to 128. Even with the maximum expansion, the size is only W 105 × H 90 × D 60 mm W 4.134 × H 3.543 × D 2.362 inch. The ultra-compact body size and installation area beyond comparison with the conventional compact PLCs facilitate the miniaturization of target machines, equipment, and control panels. ● Three selectable installation methods ● Password protection Program rewriting can be password-protected. Program rewriters can be limited, enhancing maintenance reliability. Up to three expansion units can be directly connected without connection cables. The expansion units can be directly connected to the control unit with a simple operation using the expansion connector and lock lever on the unit side. Dedicated cables or motherboards are not necessary for expansion. High-speed operation of 0.9 µs per basic instruction meets the need for a quick response. ● High-speed operation Each basic instruction can be operated in 0.9 µs. A 500-step program can be scanned in approx. 1 ms. The highest processing speed in this class of controller has been achieved. ● Pulse catch function Can read pulses as short as 50 µs. Ideal for sensor input. ● Interrupt input function Reliable processing is available without being affected by the scan time. DIN rail 2 Slim type mounting plate Flat type mounting plate* * Cannot be used for Control unit Expansion unit Expansion unit Expansion unit to 3 units (Up can be added. ) 3 Excellent space-saving design! 25 mm 105 mm .984 inch 4.134 inch Control unit Expansion unit Expansion unit Expansion unit Actual size image A terminal block type and a connector type are available. Both can be detached for easy wiring. ● Terminal block ● Connector ● MIL connector Terminal block type (European type, made by Phoenix Contact): Installation of electric wires having a cross section of 0.2 to 1.25 mm2 is possible without crimp terminals. Connector type (made by Molex): Ideal for installation during mass production. Installation of electric wires having a cross section of 0.2 to 0.75 mm2 is available Wire-press sockets are attached to the units with 16 or 32 I/O points. Installation of electric wires having a cross section of 0.2 to 0.3 mm2 is possible without stripping the wire cover. Available for: FP0-C10RS, C10CRS, C14RS, C14CRS, E8RS, E8YRS, E16RS Available for: FP0-C10RM, C10CRM, C14RM, C14CRM, E8RM, E16RM Available for: FP0-C16T, C16CT, C32T, C32CT, T32CT, E8X, E8YT, E16X, E16YT, E16T,E32T Wide variety of intelligent units ● Analog unit ● Thermocouple unit Analog I/O, A/D conversion, and D/A conversion units are available. Up to three units can be connected, allowing multi-channel analog control. Total accuracy: ± 0.8 °C (K/J/T range). Two types are available: 4-ch/8-ch types. Up to three units can be connected, allowing highaccuracy multi-point temperature control of a maximum of 24 channels. 90 mm 3.543 inch Input/Output terminals Control unit with 14 I/O points Control unit with 32 I/O points + 3 expansion units with 32 I/O points = 128 I/O points (Maximum allowable number of I/O points) EEPROM is used as the program memory. Program rewriting is possible even when running! Tool port Communications with the "Control FPWIN GR" software for programming from a personal computer is possible with only one cable. Available for: FP0-A21, FP0-A80, FP0-A04V, FP0-A04I Available for: FP0-TC4, FP0-TC8 ● CC-Link slave unit ● I/O link unit Supports CC-Link, which is an open network. Reading/Writing of fourword data through a maximum of 16 input and 16 output points. A link unit to enable FP0 to serve as a slave station of MEWNET-F (remote I/O system). Available for: FP0-CCLS Available for: FP0-IOL ● S-LINK control unit ● Power supply unit Can be directly connected to the SLINK wire-saving system and control up to 64 input and 64 output points. * S-LINK is a trademark of SUNX Limited. A power supply unit having the same height and depth as that of FP0. Input: 100 to 240 V AC universal. Output: 24 V AC up to 0.7 A Available for: FP0-SL1 Available for: FP0-PSA4 ● Rewriting in RUN mode Programs can be rewritten for debugging or activation adjustments during the operation of FP0. ● No backup battery required From 10 I/O points EEPROM is used as the program memory. Programs and device data can be stored without backup batteries, ensuring safe use in mass-produced machines. Up to 128 I/O points The control unit width is only 25 mm .984 inch*. Only 105 mm 4.134 inch even in combination with expansion units having a maximum of 128 I/O points * The width of the control unit with 32 I/O points and the S-LINK control unit is 30 mm 1.181 inch. The control unit can fit in your pocket: W 25 × H 90 × D 60 mm W .984 × H 3.543 × D 2.362 inch The number of I/O points can be expanded up to 128. Even with the maximum expansion, the size is only W 105 × H 90 × D 60 mm W 4.134 × H 3.543 × D 2.362 inch. The ultra-compact body size and installation area beyond comparison with the conventional compact PLCs facilitate the miniaturization of target machines, equipment, and control panels. ● Three selectable installation methods ● Password protection Program rewriting can be password-protected. Program rewriters can be limited, enhancing maintenance reliability. Up to three expansion units can be directly connected without connection cables. The expansion units can be directly connected to the control unit with a simple operation using the expansion connector and lock lever on the unit side. Dedicated cables or motherboards are not necessary for expansion. High-speed operation of 0.9 µs per basic instruction meets the need for a quick response. ● High-speed operation Each basic instruction can be operated in 0.9 µs. A 500-step program can be scanned in approx. 1 ms. The highest processing speed in this class of controller has been achieved. ● Pulse catch function Can read pulses as short as 50 µs. Ideal for sensor input. ● Interrupt input function Reliable processing is available without being affected by the scan time. DIN rail 2 Slim type mounting plate Flat type mounting plate* * Cannot be used for Control unit Expansion unit Expansion unit Expansion unit to 3 units (Up can be added. ) 3 FP0 Features FP0 Equipped with 2-axis independent positioning, high-speed counter and PWM output Can be directly connected to the S-LINK wire-saving system (SUNX Ltd.). ● Pulse output function (For transistor output type only) ● High-speed counter function The FP0 comes equipped with 2 channels of pulse output up to 10 kHz (5 kHz during 2-channel output). Since these two channels can be separately controlled, the FP0 is also suitable for 2-axis independent positioning. Setting for automatic trapezoid control, automatic return to home position and JOG operation are very easy, by using special instructions. The high-speed counter is prepared for 4 channels in single phase, and 2 channels in 2-phase. In single phase, the 4-channel total is 10 kHz, and in 2-phase the 2channel total is 2 kHz total speed, making the unit suitable for inverter control, and so forth. Feeder roller Y0 Y2 Y1 Y3 FP0 S-LINK Control unit W30 × H90 × D60 W1.181 × H3.543 × D2.362 Cutter Pulse output Motor driver 1 cw/ccw Stepping motor Servo motor Pulse output Inverter cw/ccw (300 m sec) (300 m sec) ● High speed (7 kHz) R0 F0 MV H102, DT0 Control code F0 MV K500, DT1 Initial speed (500 Hz) F0 MV K7000, DT2 F0 MV K300, DT3 F1 DMV K300000, DT4 F0 MV F168 SPD1 ● Initial speed (500 Hz) High speed (7 kHz) Deceleration/Acceleration time (300 m sec) START/ STOP signal Encoder Stepping motor Servo motor Motor driver 2 Cutter blade control signal Input encoder output into the high-speed counter T-branch multi drop wiring (For transistor output type only) Its PWM output (Pulse Width Modulation output) function makes it possible to provide temperature control with a single compact FP0 unit. ● When pulse width values are increased... ● Output pulse count (300,000) Output pulse count (300,000) Pulse output starts from Y0 2 signal wires 2 power supply wires ● PWM output function Heater power up K0, DT6 DT0, K0 Maximum length: 200 m 656.168 ft. Max. 128 points Lead wire and tape Motor Position control is a breeze with the auto trapezoid control instruction F168! ● Acceleration time ● Acceleration time DF The FP0 S-Link control unit makes sensor wiring and control panel simple by using easy T-shape connectability and 4-wire cable. It can control up to 128 input/output of S-Link I/O devices. Adding up to three FP0 Expansion units you can have flexible I/O configuration capability. ● When reduced... ● Simply set the values for each point Surveillance possible of FP0 operation status from a Web browser using FP Web-Server Unit Connecting an FP0 to the FP Web-Server unit with an RS232C cable and then setting up using the dedicated software (FP Web Configurator Tool) makes surveillance possible of the FP0 running conditions from a PC Web browser. Ethernet Heater power down FP Web-Server Unit RS232C port enables serial communications. (Product No. C10CR, C14CR, C16CT, C32CT, T32CT, SL1) The RS232C port allows the direct connection to computers and operation display panels. Also, bidirectional data communication with bar-code readers and other RS232C devices is made easy. FP0 ● For connecting to computers and operation display panels * The port block is connected by three S.R.G. terminals. Operation display panels can also be connected using the tool port. * RS232C port is equipped on the control units for both relay types and transistor output types. Host computer (Personal computer) Operation display panel By using C-NET, you can use multiple FP0s as data collection terminals. ● For data communication with RS232C devices FP0 RS-232C POWER COM COM D2 READY MODE A FLASH D1 D4 D3 D6 D5 D8 D9 D7 READY MICRO-IMAGECHECKER KEY PAD B M100 C Matsuhita Electronic Works, Ltd. CAMERA MONITOR 24VDC START ACK IN1 IN3 IN5 COM COM IN2 IN4 COM Image checker Bar-code reader Serial printer Wide variety of analog units available ● PCWAY Pressure sensor Inverter RUN MODE PROG 1 2 3 4 5 ERROR ALARM RUN OFF ON PROG. V0 I 0 IN COM V1 I 1 V Laser analog sensor OUT I COM FP0 - A21 Even with compact body, the following analog units are available. FP0-A21 (AFP0480) : 2 input, 1 output FP0-A80 (AFP0401) : 8 input FP0-A04V (AFP04121) : Voltage 4 output FP0-A04I (AFP04123) : Current 4 output FP0-TC4 (AFP0420) : Thermocouple 4 input FP0-TC8 (AFP0421) : Thermocouple 8 input By using the C-NET network and exclusive adapters, you can connect multiple FP0s by multi-drop connection with 2wire cables. You can use computers for distributed control or have network terminals for a centralized management system. Potentio meter The Excel add-in software ìPCWAYî is available for data collection of the networked PLCs. PLC status and data registers value can be simply shown and managed on Excel worksheets, which also makes it possible to transmit Email when malfunctions occur or to make status inquiries. PCWAY C-NET adapter to 200 V AC : AFP8536 ( 100 24 V DC : AFP8532 ) Max. 32 units Max. 1,200 m 3,937.008 ft. C-NET adapter S2 type (AFP15402) FP0 Thermocouple 4 5 FP0 Features FP0 Equipped with 2-axis independent positioning, high-speed counter and PWM output Can be directly connected to the S-LINK wire-saving system (SUNX Ltd.). ● Pulse output function (For transistor output type only) ● High-speed counter function The FP0 comes equipped with 2 channels of pulse output up to 10 kHz (5 kHz during 2-channel output). Since these two channels can be separately controlled, the FP0 is also suitable for 2-axis independent positioning. Setting for automatic trapezoid control, automatic return to home position and JOG operation are very easy, by using special instructions. The high-speed counter is prepared for 4 channels in single phase, and 2 channels in 2-phase. In single phase, the 4-channel total is 10 kHz, and in 2-phase the 2channel total is 2 kHz total speed, making the unit suitable for inverter control, and so forth. Feeder roller Y0 Y2 Y1 Y3 FP0 S-LINK Control unit W30 × H90 × D60 W1.181 × H3.543 × D2.362 Cutter Pulse output Motor driver 1 cw/ccw Stepping motor Servo motor Pulse output Inverter cw/ccw (300 m sec) (300 m sec) ● High speed (7 kHz) R0 F0 MV H102, DT0 Control code F0 MV K500, DT1 Initial speed (500 Hz) F0 MV K7000, DT2 F0 MV K300, DT3 F1 DMV K300000, DT4 F0 MV F168 SPD1 ● Initial speed (500 Hz) High speed (7 kHz) Deceleration/Acceleration time (300 m sec) START/ STOP signal Encoder Stepping motor Servo motor Motor driver 2 Cutter blade control signal Input encoder output into the high-speed counter T-branch multi drop wiring (For transistor output type only) Its PWM output (Pulse Width Modulation output) function makes it possible to provide temperature control with a single compact FP0 unit. ● When pulse width values are increased... ● Output pulse count (300,000) Output pulse count (300,000) Pulse output starts from Y0 2 signal wires 2 power supply wires ● PWM output function Heater power up K0, DT6 DT0, K0 Maximum length: 200 m 656.168 ft. Max. 128 points Lead wire and tape Motor Position control is a breeze with the auto trapezoid control instruction F168! ● Acceleration time ● Acceleration time DF The FP0 S-Link control unit makes sensor wiring and control panel simple by using easy T-shape connectability and 4-wire cable. It can control up to 128 input/output of S-Link I/O devices. Adding up to three FP0 Expansion units you can have flexible I/O configuration capability. ● When reduced... ● Simply set the values for each point Surveillance possible of FP0 operation status from a Web browser using FP Web-Server Unit Connecting an FP0 to the FP Web-Server unit with an RS232C cable and then setting up using the dedicated software (FP Web Configurator Tool) makes surveillance possible of the FP0 running conditions from a PC Web browser. Ethernet Heater power down FP Web-Server Unit RS232C port enables serial communications. (Product No. C10CR, C14CR, C16CT, C32CT, T32CT, SL1) The RS232C port allows the direct connection to computers and operation display panels. Also, bidirectional data communication with bar-code readers and other RS232C devices is made easy. FP0 ● For connecting to computers and operation display panels * The port block is connected by three S.R.G. terminals. Operation display panels can also be connected using the tool port. * RS232C port is equipped on the control units for both relay types and transistor output types. Host computer (Personal computer) Operation display panel By using C-NET, you can use multiple FP0s as data collection terminals. ● For data communication with RS232C devices FP0 RS-232C POWER COM COM D2 READY MODE A FLASH D1 D4 D3 D6 D5 D8 D9 D7 READY MICRO-IMAGECHECKER KEY PAD B M100 C Matsuhita Electronic Works, Ltd. CAMERA MONITOR 24VDC START ACK IN1 IN3 IN5 COM COM IN2 IN4 COM Image checker Bar-code reader Serial printer Wide variety of analog units available ● PCWAY Pressure sensor Inverter RUN MODE PROG 1 2 3 4 5 ERROR ALARM RUN OFF ON PROG. V0 I 0 IN COM V1 I 1 V Laser analog sensor OUT I COM FP0 - A21 Even with compact body, the following analog units are available. FP0-A21 (AFP0480) : 2 input, 1 output FP0-A80 (AFP0401) : 8 input FP0-A04V (AFP04121) : Voltage 4 output FP0-A04I (AFP04123) : Current 4 output FP0-TC4 (AFP0420) : Thermocouple 4 input FP0-TC8 (AFP0421) : Thermocouple 8 input By using the C-NET network and exclusive adapters, you can connect multiple FP0s by multi-drop connection with 2wire cables. You can use computers for distributed control or have network terminals for a centralized management system. Potentio meter The Excel add-in software ìPCWAYî is available for data collection of the networked PLCs. PLC status and data registers value can be simply shown and managed on Excel worksheets, which also makes it possible to transmit Email when malfunctions occur or to make status inquiries. PCWAY C-NET adapter to 200 V AC : AFP8536 ( 100 24 V DC : AFP8532 ) Max. 32 units Max. 1,200 m 3,937.008 ft. C-NET adapter S2 type (AFP15402) FP0 Thermocouple 4 5 FP0 Unit list FP0 ■ Control units 10 points: Input: 6, Relay output: 4 ● Units having 10 to 32 I/O points are available depending on the output type. ● A model having an RS232C port has been added to each type. ● A type that can be directly connected to the S-LINK wire-saving system (SUNX Ltd.) is also available. ● A 10-k step type with a calendar timer function and an RS232C port is also available. ● Precautions for selection PNP transistor output type is also available. Replace "4" in the second last digit of Product No. with "5" to order the PNP output type. The price is the same. 90 3.543 90 3.543 90 3.543 60 2.362 25 .984 Terminal block type FP0-C10RS AFP02123 25 .984 60 2.362 Connector type FP0-C10RM AFP02113 16 points: Input: 16 14 points: Input: 8, Relay output: 6 90 3.543 90 3.543 60 2.362 25 .984 Terminal block type FP0-C14RS AFP02223 25 .984 60 2.362 25 .984 10 points (with RS232C): Input: 8, Relay output: 6 90 3.543 90 3.543 60 2.362 16 points: Input: 8, Transistor output: 8 25 .984 60 2.362 25 .984 Terminal block type FP0-C10CRS AFP02123C 25 .984 60 2.362 Connector type FP0-C10CRM AFP02113C 32 points: Input: 16, Transistor output: 16 MIL connector FP0-E32T AFP03543 8 points: Relay output: 8 8 points: Transistor output: 8 16 points: Transistor output: 16 90 3.543 90 3.543 60 2.362 Terminal block type FP0-C14CRS AFP02223C 25 .984 25 .984 60 2.362 60 2.362 60 2.362 25 .984 Terminal block FP0-E8YRS AFP03020 Connector type FP0-C14CRM AFP02213C S-LINK: Input: 64, Output: 64 (S-LINK section) 60 2.362 25 .984 MIL connector FP0-E16YT AFP03340 MIL connector FP0-E8YT AFP03040 ■ Intelligent units ● Addition of the analog I/O unit to the lineup enabled analog control by FP0. Analog I/O unit A/D converter unit D/A converter unit D/A converter unit Input: 2 ch, Output: 1 ch Input: 8 ch Voltage output: 4 ch Current output: 4 ch 90 3.543 90 3.543 Thermocouple unit 90 3.543 60 2.362 60 2.362 60 2.362 30 1.181 30 1.181 25 .984 60 2.362 25 .984 90 3.543 25 .984 90 3.543 90 3.543 60 2.362 MIL connector FP0-E16T AFP03343 90 3.543 90 3.543 90 3.543 MIL connector FP0-E16X AFP03303 Connector type FP0-C14RM AFP02213 10 points (with RS232C): Input: 6, Relay output: 4 32 points: Input: 16, Transistor output: 16 90 3.543 E.g.: AFP02543 → AFP02553 The last character of the product number for the NPN output type is "T", and that for the PNP output type is "P". NPN output type: FP0-C16T → PNP output type: FP0-C16P 16 points: Input: 8, Transistor output: 8 MIL connector FP0-C16T AFP02343 MIL connector FP0-C32T AFP02543 4-wire S-LINK cable * with an RS232C port FP0-SL1 AFP02700 16 points (with RS232C): Input: 8, Transistor output: 8 32 points (with RS232C): Input: 16, Transistor output: 16 32 points (with RS232C) 10-k step type: Input: 16, Transistor output: 16 90 3.543 90 3.543 60 2.362 60 2.362 25 .984 60 2.362 25 .984 Terminal block FP0-A21 AFP0480 90 3.543 60 2.362 25 .984 Terminal block FP0-A80 AFP0401 60 2.362 25 .984 Terminal block FP0-A04V AFP04121 Terminal block FP0-A04I AFP04123 25 .984 4ch FP0-TC4 AFP0420 8ch FP0-TC8 AFP0421 ■ Link/communication units 90 3.543 90 3.543 25 .984 FP0 CC-Link slave unit 90 3.543 60 2.362 60 2.362 30 1.181 MIL connector FP0-C32CT AFP02543C MIL connector FP0-T32CT AFP02643C 90 3.543 90 3.543 ■ Expansion units 16 points: Input: 8, Relay output: 8 8 points: Input: 8 I/O link unit FP0-IOL AFP0732 25 .984 60 2.362 Terminal block type FP0-E8RS AFP03023 6 90 3.543 25 .984 60 2.362 Connector type FP0-E8RM AFP03013 90 3.543 25 .984 60 2.362 Terminal block type FP0-E16RS AFP03323 60 2.362 Adapter to link with a host computer With a 30-cm 1.181-inch dedicated cable. No power supply required. AFP15402 25 .984 FP-WEB AFP0610 ■ Power supply unit and others Power supply Input: 100 to 240 V AC, Output: 24 V DC, 0.7 A 90 3.543 90 3.543 25 .984 FP0-CCLS AFP07943 ● The input-only and output-only types added to the lineup enhance the flexibility of I/O expansion. 90 3.543 FP Web-Server unit 60 2.362 60 2.362 25 .984 8 points: Input: 4, Relay output: 4 C-NET adapter S2 type 60 2.362 30 1.181 MIL connector FP0-C16CT AFP02343C I/O link unit FP memory loader 90 3.543 25 .984 90 3.543 60 2.362 Connector type FP0-E16RM AFP03313 60 2.362 25 .984 MIL connector FP0-E8X AFP03003 60 2.362 35 1.378 FP0-PSA4 AFP0634 Data clear type/Data hold type AFP8670/AFP8671 7 FP0 Unit list FP0 ■ Control units 10 points: Input: 6, Relay output: 4 ● Units having 10 to 32 I/O points are available depending on the output type. ● A model having an RS232C port has been added to each type. ● A type that can be directly connected to the S-LINK wire-saving system (SUNX Ltd.) is also available. ● A 10-k step type with a calendar timer function and an RS232C port is also available. ● Precautions for selection PNP transistor output type is also available. Replace "4" in the second last digit of Product No. with "5" to order the PNP output type. The price is the same. 90 3.543 90 3.543 90 3.543 60 2.362 25 .984 Terminal block type FP0-C10RS AFP02123 25 .984 60 2.362 Connector type FP0-C10RM AFP02113 16 points: Input: 16 14 points: Input: 8, Relay output: 6 90 3.543 90 3.543 60 2.362 25 .984 Terminal block type FP0-C14RS AFP02223 25 .984 60 2.362 25 .984 10 points (with RS232C): Input: 8, Relay output: 6 90 3.543 90 3.543 60 2.362 16 points: Input: 8, Transistor output: 8 25 .984 60 2.362 25 .984 Terminal block type FP0-C10CRS AFP02123C 25 .984 60 2.362 Connector type FP0-C10CRM AFP02113C 32 points: Input: 16, Transistor output: 16 MIL connector FP0-E32T AFP03543 8 points: Relay output: 8 8 points: Transistor output: 8 16 points: Transistor output: 16 90 3.543 90 3.543 60 2.362 Terminal block type FP0-C14CRS AFP02223C 25 .984 25 .984 60 2.362 60 2.362 60 2.362 25 .984 Terminal block FP0-E8YRS AFP03020 Connector type FP0-C14CRM AFP02213C S-LINK: Input: 64, Output: 64 (S-LINK section) 60 2.362 25 .984 MIL connector FP0-E16YT AFP03340 MIL connector FP0-E8YT AFP03040 ■ Intelligent units ● Addition of the analog I/O unit to the lineup enabled analog control by FP0. Analog I/O unit A/D converter unit D/A converter unit D/A converter unit Input: 2 ch, Output: 1 ch Input: 8 ch Voltage output: 4 ch Current output: 4 ch 90 3.543 90 3.543 Thermocouple unit 90 3.543 60 2.362 60 2.362 60 2.362 30 1.181 30 1.181 25 .984 60 2.362 25 .984 90 3.543 25 .984 90 3.543 90 3.543 60 2.362 MIL connector FP0-E16T AFP03343 90 3.543 90 3.543 90 3.543 MIL connector FP0-E16X AFP03303 Connector type FP0-C14RM AFP02213 10 points (with RS232C): Input: 6, Relay output: 4 32 points: Input: 16, Transistor output: 16 90 3.543 E.g.: AFP02543 → AFP02553 The last character of the product number for the NPN output type is "T", and that for the PNP output type is "P". NPN output type: FP0-C16T → PNP output type: FP0-C16P 16 points: Input: 8, Transistor output: 8 MIL connector FP0-C16T AFP02343 MIL connector FP0-C32T AFP02543 4-wire S-LINK cable * with an RS232C port FP0-SL1 AFP02700 16 points (with RS232C): Input: 8, Transistor output: 8 32 points (with RS232C): Input: 16, Transistor output: 16 32 points (with RS232C) 10-k step type: Input: 16, Transistor output: 16 90 3.543 90 3.543 60 2.362 60 2.362 25 .984 60 2.362 25 .984 Terminal block FP0-A21 AFP0480 90 3.543 60 2.362 25 .984 Terminal block FP0-A80 AFP0401 60 2.362 25 .984 Terminal block FP0-A04V AFP04121 Terminal block FP0-A04I AFP04123 25 .984 4ch FP0-TC4 AFP0420 8ch FP0-TC8 AFP0421 ■ Link/communication units 90 3.543 90 3.543 25 .984 FP0 CC-Link slave unit 90 3.543 60 2.362 60 2.362 30 1.181 MIL connector FP0-C32CT AFP02543C MIL connector FP0-T32CT AFP02643C 90 3.543 90 3.543 ■ Expansion units 16 points: Input: 8, Relay output: 8 8 points: Input: 8 I/O link unit FP0-IOL AFP0732 25 .984 60 2.362 Terminal block type FP0-E8RS AFP03023 6 90 3.543 25 .984 60 2.362 Connector type FP0-E8RM AFP03013 90 3.543 25 .984 60 2.362 Terminal block type FP0-E16RS AFP03323 60 2.362 Adapter to link with a host computer With a 30-cm 1.181-inch dedicated cable. No power supply required. AFP15402 25 .984 FP-WEB AFP0610 ■ Power supply unit and others Power supply Input: 100 to 240 V AC, Output: 24 V DC, 0.7 A 90 3.543 90 3.543 25 .984 FP0-CCLS AFP07943 ● The input-only and output-only types added to the lineup enhance the flexibility of I/O expansion. 90 3.543 FP Web-Server unit 60 2.362 60 2.362 25 .984 8 points: Input: 4, Relay output: 4 C-NET adapter S2 type 60 2.362 30 1.181 MIL connector FP0-C16CT AFP02343C I/O link unit FP memory loader 90 3.543 25 .984 90 3.543 60 2.362 Connector type FP0-E16RM AFP03313 60 2.362 25 .984 MIL connector FP0-E8X AFP03003 60 2.362 35 1.378 FP0-PSA4 AFP0634 Data clear type/Data hold type AFP8670/AFP8671 7 FP0 Unit combinations FP0 ■ Unit combination limitations ■ Expansion method ● Up to three expansion or intelligent units can be added to one control unit. ● There is no limitation on the type or the order of units to be added. ● A mixed combination of the relay output type and the transistor output type is also possible. ● Additional cables are not necessary for expansion because the units can be directly connected to one another using the expansion connector and lock lever on the unit side. Control unit Expansion unit Expansion unit )+( Expansion unit 3 Expansion unit ● Relay output type combinations ( Total number of I/O points = Input 6 Output 6 = Input 8 Output 8 = Input 6 Output 10 = Input 8 Output 12 = Input 6 = Input 6 = Input 8 = Input 8 = Input 6 = Input 6 = Input 8 = Input 8 18 Input 10 22 Input 12 26 Input 14 30 Input 16 Output 14 34 Input 18 Output 16 38 Input 20 Output 18 42 Input 22 Output 20 8 Output 4 Output 4 14 Output 6 14 Output 6 10 Output 4 10 Output 4 14 Output 6 14 Output 6 10 Input 6 Output 4 10 Input 8 Output 24 = Input 6 Output 26 = Input 8 Output 28 = Input 6 Output 30 = Input 8 62 Input 32 Output 6 10 = 58 Input 30 Output 4 10 Input 8 54 Input 28 X40 - / Y40 - X60 - / Y60 - ) of ( TotalI/Onumber ) = ( Control unit ) + (Expansion unit 1) + ( Expansion unit 2 ) + ( Expansion unit 3 ) points X20 - / Y20 - 16 = Input 8 Output 16 = Input 16 = Input 8 = Input 16 = Input 8 = Input 8 = Input 16 Output 4 = Input 16 Output 4 = Input 8 = Input 8 = Input 16 = Input 16 = Input 8 = Input 8 = Input 16 Output 4 = Input 16 Output 4 = Input 8 = Input 16 = Input 8 = Input 16 32 Input 16 Output 4 14 Output 6 14 Output 6 10 Output 4 14 Output 6 10 Output 4 14 Output 6 8 + Input 4 + Input 4 + Input 8 + Input 4 + Input 8 + Input 4 + Input 8 + Input 4 + Input 8 + Input 4 + Output 4 48 8 Input 24 Output 4 Output 24 16 Output 8 8 Output 4 + 8 Input 4 Output 4 16 8 Output 8 + Input 4 Output 4 + Input 4 Output 8 + Input 4 Output 4 + Input 4 16 8 16 Output 8 16 Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 Output 8 16 Output 8 16 Output 8 16 Output 8 16 Output 8 16 Output 8 16 Output 8 + Output 32 8 Input 4 8 + Input 32 + Output 4 16 Input 8 64 Output 8 8 8 Output 4 + 8 Input 4 Output 4 8 80 Output 4 8 Output 4 Input 40 + Output 40 8 Input 4 Output 4 16 Input 8 Output 8 8 + Input 4 + Input 8 + Input 4 + Input 8 + Input 8 + Input 8 + Input 8 Output 4 + 8 Input 4 Output 4 16 96 Output 8 8 Output 4 16 Output 8 16 Output 8 16 Output 8 16 Output 8 Input 48 Output 48 8 + Input 4 + Input 4 + Input 4 + Input 8 + Input 8 8 8 112 Output 4 Input 56 Output 56 16 Output 8 16 Output 8 128 Input 64 Output 64 X40 - / Y40 - X60 - / Y60 - 16 Output 8 Input 8 Output 6 14 = 50 Input 26 X20 - / Y20 - Output 4 10 Input 6 Output 22 Expansion unit 2 14 = 46 Input 24 = )+( Expansion unit 1 10 Output 4 14 Input 8 ● Transistor output type combinations ) = ( Control unit ) + ( 10 Input 6 Up to 3 units can be added. Output 8 32 Output 16 16 Output 8 32 Output 16 16 Output 8 16 Output 8 32 Output 16 32 Output 16 16 Output 8 16 Output 8 32 Output 16 32 Output 16 16 Output 8 16 Output 8 32 Output 16 32 Output 16 16 Output 8 32 Output 16 16 Output 8 32 Output 16 16 + Input 8 + Input 8 + Input 16 + Input 8 + Input 16 + Input 8 + Input 16 + Input 8 + Input 16 + Input 8 + Input 16 + Input 16 + Input 16 + Input 16 + Input 16 + Input 16 + Input 16 + Input 16 Output 8 16 Output 8 32 Output 16 16 Output 8 16 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 16 + Input 8 + Input 16 + Input 8 + Input 16 + Input 16 + Input 16 + Input 16 Output 8 32 Output 16 16 Output 8 32 Output 16 16 Output 8 32 Output 16 16 Output 8 32 Output 16 32 Output 16 32 Output 16 32 Output 16 32 Output 16 32 Output 16 32 Output 16 32 Output 16 16 Output 8 16 Output 8 16 Output 8 16 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 16 + Input 16 Output 8 16 Output 8 16 Output 8 16 Output 8 32 Output 16 16 Output 8 16 Output 8 32 Output 16 16 Output 8 32 Output 16 32 Output 16 32 Output 16 32 Output 16 16 Output 8 16 Output 8 16 Output 8 32 Output 16 32 Output 16 9 FP0 Unit combinations FP0 ■ Unit combination limitations ■ Expansion method ● Up to three expansion or intelligent units can be added to one control unit. ● There is no limitation on the type or the order of units to be added. ● A mixed combination of the relay output type and the transistor output type is also possible. ● Additional cables are not necessary for expansion because the units can be directly connected to one another using the expansion connector and lock lever on the unit side. Control unit Expansion unit Expansion unit )+( Expansion unit 3 Expansion unit ● Relay output type combinations ( Total number of I/O points = Input 6 Output 6 = Input 8 Output 8 = Input 6 Output 10 = Input 8 Output 12 = Input 6 = Input 6 = Input 8 = Input 8 = Input 6 = Input 6 = Input 8 = Input 8 18 Input 10 22 Input 12 26 Input 14 30 Input 16 Output 14 34 Input 18 Output 16 38 Input 20 Output 18 42 Input 22 Output 20 8 Output 4 Output 4 14 Output 6 14 Output 6 10 Output 4 10 Output 4 14 Output 6 14 Output 6 10 Input 6 Output 4 10 Input 8 Output 24 = Input 6 Output 26 = Input 8 Output 28 = Input 6 Output 30 = Input 8 62 Input 32 Output 6 10 = 58 Input 30 Output 4 10 Input 8 54 Input 28 X40 - / Y40 - X60 - / Y60 - ) of ( TotalI/Onumber ) = ( Control unit ) + (Expansion unit 1) + ( Expansion unit 2 ) + ( Expansion unit 3 ) points X20 - / Y20 - 16 = Input 8 Output 16 = Input 16 = Input 8 = Input 16 = Input 8 = Input 8 = Input 16 Output 4 = Input 16 Output 4 = Input 8 = Input 8 = Input 16 = Input 16 = Input 8 = Input 8 = Input 16 Output 4 = Input 16 Output 4 = Input 8 = Input 16 = Input 8 = Input 16 32 Input 16 Output 4 14 Output 6 14 Output 6 10 Output 4 14 Output 6 10 Output 4 14 Output 6 8 + Input 4 + Input 4 + Input 8 + Input 4 + Input 8 + Input 4 + Input 8 + Input 4 + Input 8 + Input 4 + Output 4 48 8 Input 24 Output 4 Output 24 16 Output 8 8 Output 4 + 8 Input 4 Output 4 16 8 Output 8 + Input 4 Output 4 + Input 4 Output 8 + Input 4 Output 4 + Input 4 16 8 16 Output 8 16 Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 Output 8 16 Output 8 16 Output 8 16 Output 8 16 Output 8 16 Output 8 16 Output 8 + Output 32 8 Input 4 8 + Input 32 + Output 4 16 Input 8 64 Output 8 8 8 Output 4 + 8 Input 4 Output 4 8 80 Output 4 8 Output 4 Input 40 + Output 40 8 Input 4 Output 4 16 Input 8 Output 8 8 + Input 4 + Input 8 + Input 4 + Input 8 + Input 8 + Input 8 + Input 8 Output 4 + 8 Input 4 Output 4 16 96 Output 8 8 Output 4 16 Output 8 16 Output 8 16 Output 8 16 Output 8 Input 48 Output 48 8 + Input 4 + Input 4 + Input 4 + Input 8 + Input 8 8 8 112 Output 4 Input 56 Output 56 16 Output 8 16 Output 8 128 Input 64 Output 64 X40 - / Y40 - X60 - / Y60 - 16 Output 8 Input 8 Output 6 14 = 50 Input 26 X20 - / Y20 - Output 4 10 Input 6 Output 22 Expansion unit 2 14 = 46 Input 24 = )+( Expansion unit 1 10 Output 4 14 Input 8 ● Transistor output type combinations ) = ( Control unit ) + ( 10 Input 6 Up to 3 units can be added. Output 8 32 Output 16 16 Output 8 32 Output 16 16 Output 8 16 Output 8 32 Output 16 32 Output 16 16 Output 8 16 Output 8 32 Output 16 32 Output 16 16 Output 8 16 Output 8 32 Output 16 32 Output 16 16 Output 8 32 Output 16 16 Output 8 32 Output 16 16 + Input 8 + Input 8 + Input 16 + Input 8 + Input 16 + Input 8 + Input 16 + Input 8 + Input 16 + Input 8 + Input 16 + Input 16 + Input 16 + Input 16 + Input 16 + Input 16 + Input 16 + Input 16 Output 8 16 Output 8 32 Output 16 16 Output 8 16 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 16 + Input 8 + Input 16 + Input 8 + Input 16 + Input 16 + Input 16 + Input 16 Output 8 32 Output 16 16 Output 8 32 Output 16 16 Output 8 32 Output 16 16 Output 8 32 Output 16 32 Output 16 32 Output 16 32 Output 16 32 Output 16 32 Output 16 32 Output 16 32 Output 16 16 Output 8 16 Output 8 16 Output 8 16 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 8 + Input 16 + Input 16 Output 8 16 Output 8 16 Output 8 16 Output 8 32 Output 16 16 Output 8 16 Output 8 32 Output 16 16 Output 8 32 Output 16 32 Output 16 32 Output 16 32 Output 16 16 Output 8 16 Output 8 16 Output 8 32 Output 16 32 Output 16 9 FP0 FP0 Specifications ■ Performance specifications ■ Input specification (As for the limitation on the number of simultaneous ON points, please refer to the manual.) C10 series C14 series C16 series C32 series (Relay output type only) (Relay output type only) (Transistor output type only) (Transistor output type only) Programming method / Control method No expansion (control unit only) Relay symbol / Cyclic operation 10 points 14 points 16 points 32 points [Input: 6, NPN Output: 4] [Input: 8, NPN Output: 6] [Input: 8, NPN Output: 8] [Input: 16, NPN Output: 16] Number of W/expansion 1 I/O points * Same type of control and expansion units W/expansion 2 * Mix type of relay and transistor units Max. 58 points Max. 62 points Max. 112 points Max. 128 points Max. 106 points Max. 110 points Max. 112 points Max. 128 points Program memory Program capacity 2.7 k steps Basic High-level Operation speed (central value/step) Internal relay (R) Operation Relay Timer/Counter (T/C) memory Memory Data register (DT) points area Index register (IX,IY) Master control relay points (MCR) Number of labels (JMP and LOOP) Differential points Number of step ladder Number of subroutines Number of instructions High speed counter Special functions 1,660 words − PWM output − 0.15 Hz to 1 kHz Pulse catch input/interrupt input Interrupt program 10 k steps Item Rated input voltage Operating voltage range Rated input current Input impedance Input points per common Min. ON voltage/ON current Max. OFF voltage/OFF current Response OFF → ON time 16,384 words Note 1) Since the response time of X0 to X5 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. ■ Output specification 255 labels − − − − 7 programs (external 6 points, internal 1 point) 1 program (internal 1 point) 704 stages 100 subroutines Available (same as 32 points series) Available (same as 32 points series) Available (same as 32 points series) Available (same as 32 points series) Available (same as 32 points series) 1. Relay output type Item Output type Rated control capacity Response OFF → ON time ON → OFF Mechanical Life time Electrical Surge absorber Operating indicator Stored fixed area in EEP-ROM Counter: 4 points Internal relay: 32 points Data register: 8 words Self-diagnostic function Clock/Calender function Other functions Stored fixed area in EEP-ROM Counter: 16 points Internal relay: 128 points Data register: 32 words Watchdog timer, program syntax check − Runtime editing, password setting Item Output type Rated load voltage Load voltage allowable range Description Open collector NPN type: 5 to 24 V DC, PNP type: 24 V DC NPN type: 4.75 to 26.4 V DC PNP type: 21.6 to 26.4 V DC Max. load current Max. inrush current OFF state leakage current ON state voltage drop Response OFF → ON time ON → OFF Voltage range for external power supply 0.1 A/point (1 A/common) 0.3 A 100 µA or less 1.5 V or less 1 ms or less (50 µs or less at Y0 and Y1 only) Surge absorber Zener diode 21.6 to 26.4 V DC 8 points/common (C16T, C16P, C16CT, C16CP, E16T, E16P, E8YT, E8YP) 16 points/common (C32T, C32P, C32CT, C32CP, E32T, E32P, E16YT, E16YP) Photocoupler Output points per common Insulation method Backup is provided by secondary battery. The holding range for the timers, counters internal relays, and data registers are specified with the programming tool. ■ I/O circuit diagram Relay output Transistor output (NPN) Transistor output (PNP) Input 5.6 kΩ X0 Input 5.6 kΩ X0 Available * For the limitations while operating units, see the manual. 5.6 kΩ Internal circuit Internal circuit Internal circuit Xn Xn Description 24 V DC 21.6 to 26.4 V DC 5 ms (at 21.6 V), 10 ms (at 24 V) 10 ms (at 21.6 V / 24 V) 0 to +55 °C 32 to +131 °F ñ20 to +70 °C ñ4 to +158 °F 30 to 85% RH (non-condensing) 30 to 85% RH (non-condensing) Between input/output terminals and power/ground terminals: 500 V AC for 1 minute (for the relay output type, 1500 V AC for 1 minute) Between input terminals and output terminals: 500 V AC for 1 minute (for the relay output type, 1500 V AC for 1 minute) Insulation resistance Between input/output terminals and power/ground terminals: Over 100 MΩ (using a 500V DC megger) Between input terminals and output terminals: Over 100 MΩ (using a 500V DC megger) Vibration resistance Shock resistance Noise immunity Operating condition 10 to 55 Hz, 1 sweep/min. Double amplitude of 0.75 mm .030 inch, 10 min. on 3 axes 98 m/s2 or more , 4 times on 3 axes 1,000 V (p-p) with pulse widths 50 ns and 1 µs (using a noise simulator) Free from corrosive gasses and excessive dust Internal circuit Internal circuit Input X0 (* Note 1) Xn ■ General specifications 10 Description 1a (1 form A, normally open) 2 A 250 V AC, 2 A 30 V DC (4.5 A/common) Approx. 10 ms Approx. 8 ms Min. 2 × 107 operations Min. 105 operations None LED display Stored program and system register in EEP-ROM Maintenance Breakdown voltage 2. Transistor output type One RS232C port is mounted on each of the models FP0- C10CR, C14CR, C16CT, C16CP, C32CT, C32CP, T32CT, T32CP and SL1 type (3P terminal block) Transmission speed (Baud rate): 300 to 19,200 bits/s, Transmission distance: 3 m 9.843 ft Communication method: half duplex Operation memory Rated voltage Operating voltage range Allowed momentary 10 points, 14 points type power off time 16 points, 32 points, S-LINK type Ambient temperature Storage temperature Ambient humidity Storage humidity 19.2 V / 3 mA 2.4 V / 1 mA 50 µs or less (at X0, X1) Note 1) (at 24V DC and under the ambient temperature of 25 °C 77 °F) 100 µs or less (at X2 to X5) Note 1) (at 24 V DC and under the ambient temperature of 25 °C 77 °F) 2 ms or less (at X6 onward) Same as above Photocoupler 0.5 ms to 30 s Available Program and system register Item Description 24 V DC 21.6 to 26.4 V DC Approx. 4.3 mA (at 24 V DC) Approx. 5.6 kΩ ±common, 4 points/common (E8RS/E8RM), 6 points/common (C10RS/C10RM), 8 points/common (C14RS/C14RM, C16T, E16T, E16R, E8X), 16 points/common (C32T/E32T/E16X) ON → OFF Insulation method 6 points (with high speed counter) Periodical interrupt Constant scan 32 points [Input: 16, NPN Output: 16] Expansion section: Max. 128 points Max. 96 points Max. 128 points 1 phase/4 points (10 kHz in total) or 2 phases/2 points (2 kHz in total)* Pulse output RS232C port S-LINK section: max. 128 points [Input: 64, NPN Output: 64] EEP-ROM (no back up battery required) 5 k steps 83 115 0.9 µs/step (for basic instructions) 1,008 points 114 points 6,144 words 2 words 32 points 64 labels Unlimited number of points 128 stages 16 subroutines 2 points (10 kHz* in total), enable to control 2 channels individually* Memory back up S-LINK type Internal circuit COM (* Note 1) Model T32 series (Transistor output type only) 24 V DC COM COM Output (ñ) Output Output Y0 L Internal circuit Y0 L Internal circuit Y0 L Internal circuit (+) Yn L Internal circuit COM Internal Internal circuit Yn L Internal circuit (ñ) Source Internal Yn (+) Internal L 24 V DC (Load voltage and external power supply) Note: For transistor output types, make sure that the externally supplied voltage between the (+) and (-) terminal is between 21.6 and 26.4 V DC. 11 FP0 FP0 Specifications ■ Performance specifications ■ Input specification (As for the limitation on the number of simultaneous ON points, please refer to the manual.) C10 series C14 series C16 series C32 series (Relay output type only) (Relay output type only) (Transistor output type only) (Transistor output type only) Programming method / Control method No expansion (control unit only) Relay symbol / Cyclic operation 10 points 14 points 16 points 32 points [Input: 6, NPN Output: 4] [Input: 8, NPN Output: 6] [Input: 8, NPN Output: 8] [Input: 16, NPN Output: 16] Number of W/expansion 1 I/O points * Same type of control and expansion units W/expansion 2 * Mix type of relay and transistor units Max. 58 points Max. 62 points Max. 112 points Max. 128 points Max. 106 points Max. 110 points Max. 112 points Max. 128 points Program memory Program capacity 2.7 k steps Basic High-level Operation speed (central value/step) Internal relay (R) Operation Relay Timer/Counter (T/C) memory Memory Data register (DT) points area Index register (IX,IY) Master control relay points (MCR) Number of labels (JMP and LOOP) Differential points Number of step ladder Number of subroutines Number of instructions High speed counter Special functions 1,660 words − PWM output − 0.15 Hz to 1 kHz Pulse catch input/interrupt input Interrupt program 10 k steps Item Rated input voltage Operating voltage range Rated input current Input impedance Input points per common Min. ON voltage/ON current Max. OFF voltage/OFF current Response OFF → ON time 16,384 words Note 1) Since the response time of X0 to X5 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. ■ Output specification 255 labels − − − − 7 programs (external 6 points, internal 1 point) 1 program (internal 1 point) 704 stages 100 subroutines Available (same as 32 points series) Available (same as 32 points series) Available (same as 32 points series) Available (same as 32 points series) Available (same as 32 points series) 1. Relay output type Item Output type Rated control capacity Response OFF → ON time ON → OFF Mechanical Life time Electrical Surge absorber Operating indicator Stored fixed area in EEP-ROM Counter: 4 points Internal relay: 32 points Data register: 8 words Self-diagnostic function Clock/Calender function Other functions Stored fixed area in EEP-ROM Counter: 16 points Internal relay: 128 points Data register: 32 words Watchdog timer, program syntax check − Runtime editing, password setting Item Output type Rated load voltage Load voltage allowable range Description Open collector NPN type: 5 to 24 V DC, PNP type: 24 V DC NPN type: 4.75 to 26.4 V DC PNP type: 21.6 to 26.4 V DC Max. load current Max. inrush current OFF state leakage current ON state voltage drop Response OFF → ON time ON → OFF Voltage range for external power supply 0.1 A/point (1 A/common) 0.3 A 100 µA or less 1.5 V or less 1 ms or less (50 µs or less at Y0 and Y1 only) Surge absorber Zener diode 21.6 to 26.4 V DC 8 points/common (C16T, C16P, C16CT, C16CP, E16T, E16P, E8YT, E8YP) 16 points/common (C32T, C32P, C32CT, C32CP, E32T, E32P, E16YT, E16YP) Photocoupler Output points per common Insulation method Backup is provided by secondary battery. The holding range for the timers, counters internal relays, and data registers are specified with the programming tool. ■ I/O circuit diagram Relay output Transistor output (NPN) Transistor output (PNP) Input 5.6 kΩ X0 Input 5.6 kΩ X0 Available * For the limitations while operating units, see the manual. 5.6 kΩ Internal circuit Internal circuit Internal circuit Xn Xn Description 24 V DC 21.6 to 26.4 V DC 5 ms (at 21.6 V), 10 ms (at 24 V) 10 ms (at 21.6 V / 24 V) 0 to +55 °C 32 to +131 °F ñ20 to +70 °C ñ4 to +158 °F 30 to 85% RH (non-condensing) 30 to 85% RH (non-condensing) Between input/output terminals and power/ground terminals: 500 V AC for 1 minute (for the relay output type, 1500 V AC for 1 minute) Between input terminals and output terminals: 500 V AC for 1 minute (for the relay output type, 1500 V AC for 1 minute) Insulation resistance Between input/output terminals and power/ground terminals: Over 100 MΩ (using a 500V DC megger) Between input terminals and output terminals: Over 100 MΩ (using a 500V DC megger) Vibration resistance Shock resistance Noise immunity Operating condition 10 to 55 Hz, 1 sweep/min. Double amplitude of 0.75 mm .030 inch, 10 min. on 3 axes 98 m/s2 or more , 4 times on 3 axes 1,000 V (p-p) with pulse widths 50 ns and 1 µs (using a noise simulator) Free from corrosive gasses and excessive dust Internal circuit Internal circuit Input X0 (* Note 1) Xn ■ General specifications 10 Description 1a (1 form A, normally open) 2 A 250 V AC, 2 A 30 V DC (4.5 A/common) Approx. 10 ms Approx. 8 ms Min. 2 × 107 operations Min. 105 operations None LED display Stored program and system register in EEP-ROM Maintenance Breakdown voltage 2. Transistor output type One RS232C port is mounted on each of the models FP0- C10CR, C14CR, C16CT, C16CP, C32CT, C32CP, T32CT, T32CP and SL1 type (3P terminal block) Transmission speed (Baud rate): 300 to 19,200 bits/s, Transmission distance: 3 m 9.843 ft Communication method: half duplex Operation memory Rated voltage Operating voltage range Allowed momentary 10 points, 14 points type power off time 16 points, 32 points, S-LINK type Ambient temperature Storage temperature Ambient humidity Storage humidity 19.2 V / 3 mA 2.4 V / 1 mA 50 µs or less (at X0, X1) Note 1) (at 24V DC and under the ambient temperature of 25 °C 77 °F) 100 µs or less (at X2 to X5) Note 1) (at 24 V DC and under the ambient temperature of 25 °C 77 °F) 2 ms or less (at X6 onward) Same as above Photocoupler 0.5 ms to 30 s Available Program and system register Item Description 24 V DC 21.6 to 26.4 V DC Approx. 4.3 mA (at 24 V DC) Approx. 5.6 kΩ ±common, 4 points/common (E8RS/E8RM), 6 points/common (C10RS/C10RM), 8 points/common (C14RS/C14RM, C16T, E16T, E16R, E8X), 16 points/common (C32T/E32T/E16X) ON → OFF Insulation method 6 points (with high speed counter) Periodical interrupt Constant scan 32 points [Input: 16, NPN Output: 16] Expansion section: Max. 128 points Max. 96 points Max. 128 points 1 phase/4 points (10 kHz in total) or 2 phases/2 points (2 kHz in total)* Pulse output RS232C port S-LINK section: max. 128 points [Input: 64, NPN Output: 64] EEP-ROM (no back up battery required) 5 k steps 83 115 0.9 µs/step (for basic instructions) 1,008 points 114 points 6,144 words 2 words 32 points 64 labels Unlimited number of points 128 stages 16 subroutines 2 points (10 kHz* in total), enable to control 2 channels individually* Memory back up S-LINK type Internal circuit COM (* Note 1) Model T32 series (Transistor output type only) 24 V DC COM COM Output (ñ) Output Output Y0 L Internal circuit Y0 L Internal circuit Y0 L Internal circuit (+) Yn L Internal circuit COM Internal Internal circuit Yn L Internal circuit (ñ) Source Internal Yn (+) Internal L 24 V DC (Load voltage and external power supply) Note: For transistor output types, make sure that the externally supplied voltage between the (+) and (-) terminal is between 21.6 and 26.4 V DC. 11 FP0 FP0 ■ Analog unit specifications 1. Analog input specifications Description Item FP0-A21 8 channels/unit (Number of input points can be changed 2, 4, 6 and 8 channels.) 0 to 5 V(K 0 to K 4000) Note 1)/-10 to +10 V -100 to +100 mV (K -2000 to K +2000) Note 1) 2 channels/unit Voltage range 0 to 5 V(K 0 to K 4000) Note 1)/ -10 to +10 V (K -2000 to K +2000) Note 1) Current range 0 to 20 mA (K 0 to K 4000) Note 1) 1/4000 (12 bits) 1 ms/channel Note 2) ±1% FS or less (0 to 55 °C), ±0.6% F.S or less (25 °C) 1 MΩ or more 250 Ω ±15 V ±30 mA Resolution Conversion speed Overall precision Input Voltage range impedance Current range Absolute Voltage range maximum input Current range Between analog input terminal and FP0 internal circuit: optical coupler insulation (non-insulated between channels) Between analog input terminal and I/O unit external power supply: based on insulation-type DC/DC converter Between analog input terminal and analog output terminal: based on insulation-type DC/DC converter Insulation method Number of I/O contact points Averaging function None Between analog output terminal and FP0 internal circuit: optical coupler insulation (non-insulated between channels) Between analog output terminal and D/A converter unit external power supply: based on insulationtype DC/DC converter 32 input contact points Can be switched on and off. Notes 1) If the analog input value exceeds the upper or lower limit, the digital value will preserve the upper or lower limit. 2) The number for the input contact point being used varies depending on the expansion position. FP0-A21 FP0-A21 Output range 0V Analog input 1 ms K0 WX2 Refresh standby -10 to +10 V range (K -2000 to K +2000) Note 1) Voltage range Current range 0 to 20 mA (K 0 to K 4000) Note 1) Resolution Conversion speed Overall precision Output impedance Voltage range Absolute output load resistance Voltage range Max. output current Current range 0.5 Ω or less ±10 mA 30 Ω or less 1000 Ω or less Between analog output terminal and FP0 internal circuit: optical coupler insulation Between analog output terminal and analog I/O unit extenal power supply: based on insulation-type DC/DC converter Between analog output terminal and analog input terminal: based on insulation-type DC/DC converter Insulation method note 2) Number of I/O contact points 0V Analog input WX2 Conversion time Waiting for processing K0 Conversion time 10 V 0V Analog output Refresh 1 ms × No. of 0 ms to 1 ms to scan time expansions Note 4) 1 ms × number of input channels × ( Number of input channels ) 2 Note 3) K0 Between analog output terminal and FP0 internal circuit: optical coupler insulation (non-insulated between channels) Between analog output terminal and D/A converter unit external power supply: based on insulation-type DC/DC converter K2000 WX2 1 ms × number 0 ms to scan time of expansions Refresh standby 500 Ω or less 16 output contact points 16 input contact points, 32 output contact points Note 3) Refresh 10 V FP0-A80 Transmission line Notes 1) If the digital input value exceeds the upper or lower limit, D/A conversion will not take place. (Analog output will remain as the previous data.) 2) The number for the output contact point being used varies depending on the expansion position. K2000 1 ms × number of expansions 0 ms to scan time 500 µs K2000 FP0-A04V, FP0-04 I K2000 K0 WX2 0V Analog output Conversion time 0 ms to scan time Waiting for processing 1 ms × mumber of expansions Conversion time 500 µs/1CH 1 ms/2CH 10 V 3) Settings value switch for the number of input channels. 4) With each one scan of the control unit, the data for two channels will be loaded into it. In other words, if the input channel number switch is set to 8-channel, the data in the control unit will be updated once every four scans. 3) The data for two channels will be output to the D/A converter unit with one scan of the control unit. ■ Thermocouple unit specifications ■ CC-Link slave unit specifications Item Input points Input range Digital output Description 4-channel, 8-channel (The number of input points can be changed 2, 4, 6 and 8 channels.) Thermocouple types K and J -100.0 to 500.0 °C/-148.0 to 790.0 °F Note 1) Thermocouple type T Thermocouple type R -100.0 to 400.0 °C/-148.0 to 752.0 °F 0.0 to 1500.0 °C/32.0 to 1590.0 °F Note 1) K and J (when using °C): K -1000 to K 5000 K and J (when using °F): K -1480 to K 7900 Note 1) (When range over using °C: K-1001, K 5001 or K 8000) (When range over using °F: K-1481, K 7901 or K 8000) (When the thermocouple broken: K 8000) Note 2) (Until the temperature can be measured at the initial startup: K 8001) Note 3) T (when using °C): K -1000 to K 4000 T (when using °F): K -1480 to K 7520 Note 1) (When range over using °C: K -1001, K 4001 or K 8000) (When range over using °F: K -1481, K 7521 or K 8000) (When the thermocouple broken: K8000) Note 2) (Until the temperature can be measured at the initial startup: K 8001) Note 3) R (when using °C): K 0 to K 15000 R (when using °F): K 320 to K 15900 Note 1) (When range over using °C: K 0, K 15001 or K 16000) (When range over using °F: K 0, K 15901 or K 16000) (When the thermocouple broken: K 16000) Note 2) (Until the temperature can be measured at the initial startup: K 16001) Note 3) Resolution 0.1 °C Sampling Note 5) cycle 300 ms: when using 2 channels for an input points Note 4) 500 ms: when using 4 channels for an input points Note 4) 700 ms: when using 6 channels for an input points Note 4) 900 ms: when using 8 channels for an input points Note 4) Overall accuracy Range for K and J (-100 to 500 °C): Range for T (-100 to 400 °C): Range for R (0 to 99.9 °C): (100 to 299.9 °C): (300 to 1500 °C): ±0.8 °C or less ±0.8 °C or less ±3 °C or less ±2.5 °C or less ±2 °C or less Input impedance more than 1 MΩ Insulation method • Between thermocouple input terminals and control unit internal circuits: Photo-coupler insulation/DC-DC insulation • Between thermocouple input terminal channels: PhotoMOS relay insulation 1. Communication specifications Version CC-Link Ver.1.10 Communication method Broadcast polling method Transmission speed 10 Mbits/s, 5 Mbits/s, 2.5 Mbits/s, 625 kbits/s, 156 kbits/s Ver.1.10 CC-Link cable Max. transmission CC-Link high-performace cable distance 10 Mbits/s 100 m Note 1) 160 m 400 m 900 m 1200 m 5 Mbits/s 2.5 Mbits/s 625 kbits/s 156 kbits/s Transmission distance (Total distance) Transmission speed (Baud rate) Number of control I/O point per an I/O link unit Remote I/O map allocation Interface Transmission error check 100 m 150 m 200 m 600 m 1200 m Product number Part number Rated voltage Variable input voltage range Rated frequency Frequency range Input Number of phases Surge current Leakage current Allow able momentary power off time Rated voltage Voltage accuracy Rated current Output Output current range Ripple voltage Protective Over-current protection functions Over-voltage protection K.J.T R 0 - 99.9 °C 100 - 299.9 °C 300 - 1500 °C 2 °C 6 °C 5 °C 4 °C 12 1) The measurement range available for degree Celsius is not available for degree Fahrenheit, of which the upper-limit measurement is set lower than degree Celsius, since the digital value (temperature value displayed) for degree Fahrenheit is bigger than that for degree Celsius. 2) When the thermocouple is broken, the digital value will become K8000 or K16000 within 70 seconds since broken. Practice in the ladder program a process for avoiding a risk, would be resulting from a broken thermocouple, and exchange the thermocouple. 3) Until the conversion data will be ready after the initial startup was made, the digital value shows K8001 or K16001. Those are not a temperature data. Create a ladder program, so that they are not acquired as a temperature data. 4) The settings of the input channel selection switch. 5) Conversion values for 6-time measurements (6 from the latest 8 measurements, excluding the max. and min.) are averaged, so that it takes time for the digital value to be displayed due to the rapid temperature change. 6) The control unit reads the data for 2 channels per 1 scan by the control unit. Read data by utilizing the sample program given in the product specifications and manual. 10 M bit/s (10BASE-T: RJ45) Supported protocol TCP, UDP, IP, DHCP, FTP, TELNET, HTTP, SMTP, and PPP Memory size Approx. 148 kB (for storing htm files) Setup method Setup using FP Web Configurator Tool Applicable crimp teriminals FP0-PSA4 FP0-PSA1 AFP0634 AFP0631 100 to 240 V AC 85 to 264 V AC 50/60 Hz 47 to 63 Hz Single-phase 30 A (0 - P) or less, with cold start 0.75 mA or less 10 ms or more 24 V DC ±5% 0.6 A 0.7 A Note) 0 to 0.6 A 0 to 0.7 A 500 mV or less 0.735 A or more 0.63 A or more Available Manufacturer JST Mfg.Co.,Ltd. Part number Applicable wiring V1.25-M3 (round type) V1.25-S3A (fork type) 0.35 to 1.65 mm2 AWG #22 to #15 V2-M3 (round type) V2-S3A (fork type) 1.04 to 2.00 mm2 AWG #17 to #14 7.2 mm .283 inch or less Control unit current consumption Type of unit FP0 control unit FP0 expansion unit FP0 intelligent unit Input/Output points Input: 32 points Note 6) Notes Ethernet communication ■ Current consumption When CC-Link Standard slave unit with a specifications thermocouple unit 0.8 °C 3 °C 2.5 °C 2 °C RS232C communication RS232C ⇔ Ethernet conversion (PLC remote programming via Ethernet) E-mail sending function Web-server function Transparent communication (Server/Client) PPP server function RS232C terminal block 3-pin: Mainly used for PLC connection RS232C D-Sub 9-pin: Mainly used for Modem connection 10 BASE-T (RJ45): Used for Ethernet connection and setup Transmission speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bits/s Data length: 7 bits/8 bits, Parity: Even/Odd/None Note: Start up may not be possible if a device with a large inrush current is connected even if below the rated current. In such a case, we recommend suppressing the inrush current by inserting a 1 to 2Ω resister between the power supply unit and the device. For details concerning the CC-Link, refer to the CC-Link Partner Association. When an FP0 thermocouple unit is used with an FP0 CC-Link slave unit, the measurement accuracy of the thermocouple unit which is installed on the left of the CC-Link slave unit is as shown in the table below. Communication functions Communication interface 32X/32Y Conforming to RS485 CRC (Cyclic Redumdancy Check) method ■ Power supply unit specifications The cable length has restrictions in communication speed, CC-Link version, and dedicated cables to be used. Thermocouple Max. 700 m 2,296.588 ft.(using twisted pair cable) Max. 400 m 1,312.336 ft.(using VCTF cable) 0.5 Mbits/s 64 points (Input: 32 points and Output: 32 points) note) Note: This point number is the number of points that can be linked for inputting and outputting via the host PLC and network MEWNET-F. If the output for the I/O link unit error flag is set to ON, this number becomes 63 points (31 input points and 32 output points). S-LINK control unit Length of the multi-drop connected cables at both ends ■ FP Web-Server unit specifications Description Two-wire, half duple Asynchronous method 2-wire cable (Twisted-pair cable or VCTF 0.75 mm2 × 2C equivalent) CC-Link cable Interface RS485 Station type Remote device station Number of occupied stations FPΣ: 1 to 4 stations (switch changeover), FP0: 1 station Note 1) Item Communication method Synchronous method 4 to 20 mA (K 0 to K 4000) Note 1) 1/4000 (12 bits) 500 µs/channel Note 2) ±1% F.S or less (0 to 55 °C), ±0.6% F.S. or less (25 °C) FP0-A21 Refresh FP0-A04I Voltage output: 4 channels/units Current output: 4 channels/units 1 channel/unit Number of output points 10 V Conversion time Description FP0-A04V Item FP0-A80 Number of input points Input range ■ I/O Link unit specifications 2. Analog output specifications Link/Communication units This refers to the current consumed via the power supply connector of the control unit. If expansion units or intelligent units are added, the current is increased by the value indicated below. FP0-C10 FP0-C14 FP0-C16 FP0-C32 FP0-T32 100 mA or less 100 mA or less 40 mA or less FP0-SL1 150 mA or less FP0-E8X FP0-E8R FP0-E8YR FP0-E8YT/P FP0-E16X FP0-E16R FP0-E16T/P FP0-E16YT/P FP0-E32T/P FP0-A21 FP0-A80 FP0-A04V FP0-A04I FP0-TC4 FP0-TC8 FP0-CCLS FP0-IOL FP-WEB AFP15402 (C-NET adapter) Expansion unit current consumption This refers to the current consumed via the power supply connector of the expansion unit. Units with no value indication don't have a power supply connector. 60 mA or less 10 mA or less 15 mA or less 10 mA or less 15 mA or less 20 mA or less 20 mA or less 25 mA or less 25 mA or less 40 mA or less 20 mA or less 20 mA or less 20 mA or less 20 mA or less 50 mA or less 100 mA or less 100 mA or less 100 mA or less 60 mA or less 100 mA or less 130 mA or less 25 mA or less 40 mA or less 30 mA or less 40 mA or less 40 mA or less 95 mA or less (at 24 V DC), 240 mA or less (at 12 V DC) 50 mA or less 13 FP0 FP0 ■ Analog unit specifications 1. Analog input specifications Description Item FP0-A21 8 channels/unit (Number of input points can be changed 2, 4, 6 and 8 channels.) 0 to 5 V(K 0 to K 4000) Note 1)/-10 to +10 V -100 to +100 mV (K -2000 to K +2000) Note 1) 2 channels/unit Voltage range 0 to 5 V(K 0 to K 4000) Note 1)/ -10 to +10 V (K -2000 to K +2000) Note 1) Current range 0 to 20 mA (K 0 to K 4000) Note 1) 1/4000 (12 bits) 1 ms/channel Note 2) ±1% FS or less (0 to 55 °C), ±0.6% F.S or less (25 °C) 1 MΩ or more 250 Ω ±15 V ±30 mA Resolution Conversion speed Overall precision Input Voltage range impedance Current range Absolute Voltage range maximum input Current range Between analog input terminal and FP0 internal circuit: optical coupler insulation (non-insulated between channels) Between analog input terminal and I/O unit external power supply: based on insulation-type DC/DC converter Between analog input terminal and analog output terminal: based on insulation-type DC/DC converter Insulation method Number of I/O contact points Averaging function None Between analog output terminal and FP0 internal circuit: optical coupler insulation (non-insulated between channels) Between analog output terminal and D/A converter unit external power supply: based on insulationtype DC/DC converter 32 input contact points Can be switched on and off. Notes 1) If the analog input value exceeds the upper or lower limit, the digital value will preserve the upper or lower limit. 2) The number for the input contact point being used varies depending on the expansion position. FP0-A21 FP0-A21 Output range 0V Analog input 1 ms K0 WX2 Refresh standby -10 to +10 V range (K -2000 to K +2000) Note 1) Voltage range Current range 0 to 20 mA (K 0 to K 4000) Note 1) Resolution Conversion speed Overall precision Output impedance Voltage range Absolute output load resistance Voltage range Max. output current Current range 0.5 Ω or less ±10 mA 30 Ω or less 1000 Ω or less Between analog output terminal and FP0 internal circuit: optical coupler insulation Between analog output terminal and analog I/O unit extenal power supply: based on insulation-type DC/DC converter Between analog output terminal and analog input terminal: based on insulation-type DC/DC converter Insulation method note 2) Number of I/O contact points 0V Analog input WX2 Conversion time Waiting for processing K0 Conversion time 10 V 0V Analog output Refresh 1 ms × No. of 0 ms to 1 ms to scan time expansions Note 4) 1 ms × number of input channels × ( Number of input channels ) 2 Note 3) K0 Between analog output terminal and FP0 internal circuit: optical coupler insulation (non-insulated between channels) Between analog output terminal and D/A converter unit external power supply: based on insulation-type DC/DC converter K2000 WX2 1 ms × number 0 ms to scan time of expansions Refresh standby 500 Ω or less 16 output contact points 16 input contact points, 32 output contact points Note 3) Refresh 10 V FP0-A80 Transmission line Notes 1) If the digital input value exceeds the upper or lower limit, D/A conversion will not take place. (Analog output will remain as the previous data.) 2) The number for the output contact point being used varies depending on the expansion position. K2000 1 ms × number of expansions 0 ms to scan time 500 µs K2000 FP0-A04V, FP0-04 I K2000 K0 WX2 0V Analog output Conversion time 0 ms to scan time Waiting for processing 1 ms × mumber of expansions Conversion time 500 µs/1CH 1 ms/2CH 10 V 3) Settings value switch for the number of input channels. 4) With each one scan of the control unit, the data for two channels will be loaded into it. In other words, if the input channel number switch is set to 8-channel, the data in the control unit will be updated once every four scans. 3) The data for two channels will be output to the D/A converter unit with one scan of the control unit. ■ Thermocouple unit specifications ■ CC-Link slave unit specifications Item Input points Input range Digital output Description 4-channel, 8-channel (The number of input points can be changed 2, 4, 6 and 8 channels.) Thermocouple types K and J -100.0 to 500.0 °C/-148.0 to 790.0 °F Note 1) Thermocouple type T Thermocouple type R -100.0 to 400.0 °C/-148.0 to 752.0 °F 0.0 to 1500.0 °C/32.0 to 1590.0 °F Note 1) K and J (when using °C): K -1000 to K 5000 K and J (when using °F): K -1480 to K 7900 Note 1) (When range over using °C: K-1001, K 5001 or K 8000) (When range over using °F: K-1481, K 7901 or K 8000) (When the thermocouple broken: K 8000) Note 2) (Until the temperature can be measured at the initial startup: K 8001) Note 3) T (when using °C): K -1000 to K 4000 T (when using °F): K -1480 to K 7520 Note 1) (When range over using °C: K -1001, K 4001 or K 8000) (When range over using °F: K -1481, K 7521 or K 8000) (When the thermocouple broken: K8000) Note 2) (Until the temperature can be measured at the initial startup: K 8001) Note 3) R (when using °C): K 0 to K 15000 R (when using °F): K 320 to K 15900 Note 1) (When range over using °C: K 0, K 15001 or K 16000) (When range over using °F: K 0, K 15901 or K 16000) (When the thermocouple broken: K 16000) Note 2) (Until the temperature can be measured at the initial startup: K 16001) Note 3) Resolution 0.1 °C Sampling Note 5) cycle 300 ms: when using 2 channels for an input points Note 4) 500 ms: when using 4 channels for an input points Note 4) 700 ms: when using 6 channels for an input points Note 4) 900 ms: when using 8 channels for an input points Note 4) Overall accuracy Range for K and J (-100 to 500 °C): Range for T (-100 to 400 °C): Range for R (0 to 99.9 °C): (100 to 299.9 °C): (300 to 1500 °C): ±0.8 °C or less ±0.8 °C or less ±3 °C or less ±2.5 °C or less ±2 °C or less Input impedance more than 1 MΩ Insulation method • Between thermocouple input terminals and control unit internal circuits: Photo-coupler insulation/DC-DC insulation • Between thermocouple input terminal channels: PhotoMOS relay insulation 1. Communication specifications Version CC-Link Ver.1.10 Communication method Broadcast polling method Transmission speed 10 Mbits/s, 5 Mbits/s, 2.5 Mbits/s, 625 kbits/s, 156 kbits/s Ver.1.10 CC-Link cable Max. transmission CC-Link high-performace cable distance 10 Mbits/s 100 m Note 1) 160 m 400 m 900 m 1200 m 5 Mbits/s 2.5 Mbits/s 625 kbits/s 156 kbits/s Transmission distance (Total distance) Transmission speed (Baud rate) Number of control I/O point per an I/O link unit Remote I/O map allocation Interface Transmission error check 100 m 150 m 200 m 600 m 1200 m Product number Part number Rated voltage Variable input voltage range Rated frequency Frequency range Input Number of phases Surge current Leakage current Allow able momentary power off time Rated voltage Voltage accuracy Rated current Output Output current range Ripple voltage Protective Over-current protection functions Over-voltage protection K.J.T R 0 - 99.9 °C 100 - 299.9 °C 300 - 1500 °C 2 °C 6 °C 5 °C 4 °C 12 1) The measurement range available for degree Celsius is not available for degree Fahrenheit, of which the upper-limit measurement is set lower than degree Celsius, since the digital value (temperature value displayed) for degree Fahrenheit is bigger than that for degree Celsius. 2) When the thermocouple is broken, the digital value will become K8000 or K16000 within 70 seconds since broken. Practice in the ladder program a process for avoiding a risk, would be resulting from a broken thermocouple, and exchange the thermocouple. 3) Until the conversion data will be ready after the initial startup was made, the digital value shows K8001 or K16001. Those are not a temperature data. Create a ladder program, so that they are not acquired as a temperature data. 4) The settings of the input channel selection switch. 5) Conversion values for 6-time measurements (6 from the latest 8 measurements, excluding the max. and min.) are averaged, so that it takes time for the digital value to be displayed due to the rapid temperature change. 6) The control unit reads the data for 2 channels per 1 scan by the control unit. Read data by utilizing the sample program given in the product specifications and manual. 10 M bit/s (10BASE-T: RJ45) Supported protocol TCP, UDP, IP, DHCP, FTP, TELNET, HTTP, SMTP, and PPP Memory size Approx. 148 kB (for storing htm files) Setup method Setup using FP Web Configurator Tool Applicable crimp teriminals FP0-PSA4 FP0-PSA1 AFP0634 AFP0631 100 to 240 V AC 85 to 264 V AC 50/60 Hz 47 to 63 Hz Single-phase 30 A (0 - P) or less, with cold start 0.75 mA or less 10 ms or more 24 V DC ±5% 0.6 A 0.7 A Note) 0 to 0.6 A 0 to 0.7 A 500 mV or less 0.735 A or more 0.63 A or more Available Manufacturer JST Mfg.Co.,Ltd. Part number Applicable wiring V1.25-M3 (round type) V1.25-S3A (fork type) 0.35 to 1.65 mm2 AWG #22 to #15 V2-M3 (round type) V2-S3A (fork type) 1.04 to 2.00 mm2 AWG #17 to #14 7.2 mm .283 inch or less Control unit current consumption Type of unit FP0 control unit FP0 expansion unit FP0 intelligent unit Input/Output points Input: 32 points Note 6) Notes Ethernet communication ■ Current consumption When CC-Link Standard slave unit with a specifications thermocouple unit 0.8 °C 3 °C 2.5 °C 2 °C RS232C communication RS232C ⇔ Ethernet conversion (PLC remote programming via Ethernet) E-mail sending function Web-server function Transparent communication (Server/Client) PPP server function RS232C terminal block 3-pin: Mainly used for PLC connection RS232C D-Sub 9-pin: Mainly used for Modem connection 10 BASE-T (RJ45): Used for Ethernet connection and setup Transmission speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bits/s Data length: 7 bits/8 bits, Parity: Even/Odd/None Note: Start up may not be possible if a device with a large inrush current is connected even if below the rated current. In such a case, we recommend suppressing the inrush current by inserting a 1 to 2Ω resister between the power supply unit and the device. For details concerning the CC-Link, refer to the CC-Link Partner Association. When an FP0 thermocouple unit is used with an FP0 CC-Link slave unit, the measurement accuracy of the thermocouple unit which is installed on the left of the CC-Link slave unit is as shown in the table below. Communication functions Communication interface 32X/32Y Conforming to RS485 CRC (Cyclic Redumdancy Check) method ■ Power supply unit specifications The cable length has restrictions in communication speed, CC-Link version, and dedicated cables to be used. Thermocouple Max. 700 m 2,296.588 ft.(using twisted pair cable) Max. 400 m 1,312.336 ft.(using VCTF cable) 0.5 Mbits/s 64 points (Input: 32 points and Output: 32 points) note) Note: This point number is the number of points that can be linked for inputting and outputting via the host PLC and network MEWNET-F. If the output for the I/O link unit error flag is set to ON, this number becomes 63 points (31 input points and 32 output points). S-LINK control unit Length of the multi-drop connected cables at both ends ■ FP Web-Server unit specifications Description Two-wire, half duple Asynchronous method 2-wire cable (Twisted-pair cable or VCTF 0.75 mm2 × 2C equivalent) CC-Link cable Interface RS485 Station type Remote device station Number of occupied stations FPΣ: 1 to 4 stations (switch changeover), FP0: 1 station Note 1) Item Communication method Synchronous method 4 to 20 mA (K 0 to K 4000) Note 1) 1/4000 (12 bits) 500 µs/channel Note 2) ±1% F.S or less (0 to 55 °C), ±0.6% F.S. or less (25 °C) FP0-A21 Refresh FP0-A04I Voltage output: 4 channels/units Current output: 4 channels/units 1 channel/unit Number of output points 10 V Conversion time Description FP0-A04V Item FP0-A80 Number of input points Input range ■ I/O Link unit specifications 2. Analog output specifications Link/Communication units This refers to the current consumed via the power supply connector of the control unit. If expansion units or intelligent units are added, the current is increased by the value indicated below. FP0-C10 FP0-C14 FP0-C16 FP0-C32 FP0-T32 100 mA or less 100 mA or less 40 mA or less FP0-SL1 150 mA or less FP0-E8X FP0-E8R FP0-E8YR FP0-E8YT/P FP0-E16X FP0-E16R FP0-E16T/P FP0-E16YT/P FP0-E32T/P FP0-A21 FP0-A80 FP0-A04V FP0-A04I FP0-TC4 FP0-TC8 FP0-CCLS FP0-IOL FP-WEB AFP15402 (C-NET adapter) Expansion unit current consumption This refers to the current consumed via the power supply connector of the expansion unit. Units with no value indication don't have a power supply connector. 60 mA or less 10 mA or less 15 mA or less 10 mA or less 15 mA or less 20 mA or less 20 mA or less 25 mA or less 25 mA or less 40 mA or less 20 mA or less 20 mA or less 20 mA or less 20 mA or less 50 mA or less 100 mA or less 100 mA or less 100 mA or less 60 mA or less 100 mA or less 130 mA or less 25 mA or less 40 mA or less 30 mA or less 40 mA or less 40 mA or less 95 mA or less (at 24 V DC), 240 mA or less (at 12 V DC) 50 mA or less 13 FP0 Product types FP0 4 Link/communication units 1 Control units Product name 10 Input: 6 Output: 4 24 V DC EEPROM (2.7 k steps) 10 Input: 6 Output: 4 24 V DC FP0 C14 Control Unit EEPROM (2.7 k steps) 14 Input: 8 Output: 6 24 V DC FP0 C14 Control Unit with RS232C port EEPROM (2.7 k steps) 14 Input: 6 Output: 4 24 V DC FP0 C16 Control Unit EEPROM (2.7 k steps) 16 Input: 8 Output: 8 24 V DC EEPROM (2.7 k steps) 16 Input: 8 Output: 8 24 V DC FP0 C10 Control Unit EEPROM (2.7 k steps) FP0 C10 Control Unit with RS232C port FP0 C16 Control Unit with RS232C port EEPROM (5 k steps) 32 Input: 16 Output: 16 EEPROM (5 k steps) 32 Input: 16 Output: 16 24 V DC FP0 T32 Control Unit EEPROM with RS232C port and (10 k steps) Clock/Calendar function 32 Input: 16 Output: 16 24 V DC FP0 C32 Control Unit FP0 C32 Control Unit with RS232C port FP0 S-LINK Control Unit with RS232C port Specications Built-in memory (Program Number of I/O points Power supply capacity) voltage EEPROM (5 k steps) 128 (S-LINK Input: 64 section) Output: 64 24 V DC Input Output Product number Connection type Part number FP0-C10RS FP0-C10RM FP0-C10CRS FP0-C10CRM Terminal block FP0-C14RS 24 V DC Sink/Sourse (±common) Relay output: 2 A Molex connector FP0-C14RM 24 V DC Terminal block FP0-C14CRS Sink/Sourse (±common) Relay output: 2 A Molex connector FP0-C14CRM Transistor output: FP0-C16T 24 V DC NPN 0.1 A Sink/Sourse (±common) Transistor output: MIL connector FP0-C16P PNP 0.1 A Transistor output: FP0-C16CT NPN 0.1 A 24 V DC Sink/Sourse (±common) Transistor output: MIL connector FP0-C16CP PNP 0.1 A Transistor output: FP0-C32T 24 V DC NPN 0.1 A Sink/Sourse (±common) Transistor output: MIL connector FP0-C32P PNP 0.1 A Transistor output: FP0-C32CT 24 V DC NPN 0.1 A MIL connector Transistor output: Sink/Sourse (±common) FP0-C32CP PNP 0.1 A Transistor output: 24 V DC FP0-T32CT NPN 0.1 A MIL connector Sink/Sourse (±common) Transistor output: FP0-T32CP PNP 0.1 A Terminal block 24 V DC Relay output: 2 A Sink/Sourse (±common) Molex connector Terminal block 24 V DC Relay output: 2 A Sink/Sourse (±common) Molex connector Terminal block 24 V DC AFP02123 AFP02113 AFP02123C AFP02113C AFP02223 AFP02213 AFP02223C AFP02213C Product number Part number FP0 CC-Link Slave Unit 24 V DC FP0ñCCLS AFP07943 FP0 I/O Link Unit This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system). This is an RS485 adapter designed to allow use of the Computer link function for connecting to a host computer via C-NET. It comes with a 30cm 11.811 inch FP0 tool port cable. A power supply is not required. 24 V DC FP0ñIOL AFP0732 C-NET Adapter S2 Type (for FP0 side) 100 to 240 V AC Specications This unit is for making the FP0 function as a slave station of the CC-Link. Only one unit can be connected to the furthest right edge of the FP0 expansion bus. Note: Accuracy will change if an FP0 thermocouple unit is used at the same time. For details, please refer to the catalog or to the CC-Link Unit manual. AFP02343 C-NET Adapter (RS485) (for computer side) This is an RS485 adapter designed to allow use of the Computer link function for connecting to a network-connected PLC via C-NET from a host computer. AFP02353 FP Web-Server Unit Unit for connecting FP series/RS232C interface and Ethernet Web-Server function and E-mail sending function AFP02343C AFP02353C AFP02553 AFP02543C AFP02553C Product name FP0 Power Supply Unit Product name FP0 E8 Expansion Unit FP0 E16 Expansion Unit Number of I/O points 8 Input: 8 Input: 4 Output: 4 8 Output: 8 Power supply voltage 8 16 Input: 16 16 Input: 8 Output: 8 16 Input: 8 Output: 8 16 Output:16 Output 24 V DC Sink/Sourse (±common) 8 Output: 8 Input 24 V DC 24 V DC Product number Connection type MIL connector Part number AFP03003 FP0-E8X Terminal block FP0-E8RS 24 V DC Relay output: 2 A Sink/Sourse (±common) Molex connector FP0-E8RM Relay output: 2 A Terminal block FP0-E8YRS FP0-E8YT Transistor output: MIL connector FP0-E8YP NPN 0.1 A 24 V DC MIL connector FP0-E16X Sink/Sourse (±common) AFP03023 AFP03013 AFP03020 AFP03040 AFP03050 24 V DC Terminal block Sink/Sourse (±common) Relay output: 2 A Molex connector 24 V DC Transistor output: MIL connector Sink/Sourse (±common) NPN 0.1 A AFP03323 AFP03313 AFP03343 AFP03353 AFP03340 AFP03350 AFP03543 AFP03553 Transistor output: NPN 0.1 A MIL connector FP0-E16RS FP0-E16RM FP0-E16T FP0-E16P FP0-E16YT FP0-E16YP FP0-E32T FP0-E32P AFP03303 Input: 16 Transistor output: 24 V DC FP0 E32 MIL connector 32 Output:16 NPN 0.1 A Sink/Sourse (±common) Expansion Unit Notes 1) The control units and relay output type expansion units come with a power cable (part number AFP0581). (The transistor output type expansion units need no power cable.) 2) The terminal block type relay output units have 2 terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm .098 inch wide screwdriver. Preferably use the specific terminal block screwdriver (part number AFP0806, Phoenix type code SZS0, 4 × 2.5 mm .098 inch) or equivalent. 3) The connector-type relay output units have 2 connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins). Use the specific Molex connector press-fit tool (part number AFP0805, Nihon Molex type code 57189-5000) or equivalent. 4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number AXY52000) for wire-pressed terminal cable. 3 Intelligent units Specications Product name FP0 Analog I/O Unit FP0 A/D Converter Unit FP0 D/A Converter Unit FP0 Thermocouple Unit 14 Number or channels : 2 channels Input range : 0 to 5 V, -10 to +10 V (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) Output specifications Number or channels : 1 channels Output range : -10 to +10 V (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) Input specifications Number or channels : 8 channels Input range : 0 to 5, -10 to +10 V (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) Output specifications Number or channels : 4 channels Output range : -10 to +10 V (Resolution: 1/4000) 4 to 20 mA (Resolution: 1/4000) Product number 24 V DC Part number Specications Output: 0.7 A, 24 V DC Input voltage: 100 to 240 V AC Product name AFP0480 FP0-A80 AFP0401 FP0-A04V AFP04121 K, J, T, R thermocouple, Resolution: 0.1 °C FP0-A04 I FP0-TC4 AFP04123 AFP0420 K, J, T, R thermocouple, Resolution: 0.1 °C FP0-TC8 AFP0421 AFP0610 Product number Part number FP0-PSA4 AFP0634 Standard Programming Tool Software Control FPWIN GR Ver.2 Part number Specifications English-language menu Standard Upgrade (to upgrade from Ver.1.1) AFPS10520 Chinese-language menu Standard Upgrade (to upgrade from Ver.1.1) AFPS10820 Korean-language menu Standard AFPS10920 Full type (for all type FP series PLC) AFPS50540 Small type (for FP0, FPΣ, FP1, FP-e and FP-M) AFPS51540 Upgrade (for full type) AFPS50540R Conforms to IEC61131-3 Programming Tool Software Control FPWIN Pro Ver.5 English-language menu PC Connection Cable Between D-sub 9 pins and DIN 5 pins, 3 m length AFPS10520R AFPS10820R AFC8503 7 Options and additional parts Product name Specifications Part number Data clear type AFP8670 Data hold type AFP8671 Terminal Screwdriver Relay output type Necessary when wiring terminals block (Phoenix). AFP0806 Molex Connector Pressure Contact Tool Necessary when wiring relay output type and Molex connectors. (MOLEX: 57189-5000) AFP0805 Multi-Wire Connector Pressure Contact Tool Necessary when wiring transistor output type connectors. AXY52000 Slim 30 Type Mounting Plate Screw-stop attachment plate for 30 mm 1.181 inch width the unit. AFP0811 (set for 10) Slim Type Mounting Plate Screw-stop attachment plate for FP0 expansion unit. Slim model. AFP0803 (set for 10) Flat Type Mounting Plate Screw-stop attachment plate for FP0 control unit. Flat model. FP Memory Loader AFP0804 (set for 10) Relay Output Molex Type I/O Cable Loose-wiring cable (9 leads) AWG20, with Molex socket attached at one end, 0.5 mm2, 1 set: 2 cables (blue & white). Length: 1 m 3.281 ft. AFP0551 (2 cable set) Transistor Output Type I/O Cable Wire-pressed terminal cable (10 leads) AWG22, 0.3 mm2 with connectors attached at one end, 1 set: 2 cables (blue & white). Length: 1 m 3.281 ft. AFP0521 (2 cable set) Flat Cable Connector for FPΣ/FP0 Transistor Type Unit If you are using flat cable connector, request the part specified below for a connector with an asymmetrical design to prevent mistaken polarity. (10-pin) Terminal Socket Attaches to relay output and terminal block type. Additional part Molex Socket Attaches to relay output and Molex connector types. Additional part Wire-Press Socket Attaches to transistor output type. Additional part Power Cable Attaches to FP0 various units. Additional part Length: 1 m 3.281 ft. Input specifications FP0-A21 AFP8532 FP-WEB 6 Programming tools AFP02643C AFP02653C AFP8536 24 V DC 5 Power supply unit 2 Expansion units Specications AFP15402 AFP02543 AFP02700 FP0-SL1 Power supply voltage Product name Length: 3 m 9.843 ft. AFP0553 (2 cable set) Length: 3 m 9.843 ft. AFP0523 (2 cable set) AXM110915 AFP0802 (2 sockets per pack) AFP0801 (2 sockets per pack) AFP0807 (2 sockets per pack) AFP0581 (1 socket per pack) 15 FP0 Product types FP0 4 Link/communication units 1 Control units Product name 10 Input: 6 Output: 4 24 V DC EEPROM (2.7 k steps) 10 Input: 6 Output: 4 24 V DC FP0 C14 Control Unit EEPROM (2.7 k steps) 14 Input: 8 Output: 6 24 V DC FP0 C14 Control Unit with RS232C port EEPROM (2.7 k steps) 14 Input: 6 Output: 4 24 V DC FP0 C16 Control Unit EEPROM (2.7 k steps) 16 Input: 8 Output: 8 24 V DC EEPROM (2.7 k steps) 16 Input: 8 Output: 8 24 V DC FP0 C10 Control Unit EEPROM (2.7 k steps) FP0 C10 Control Unit with RS232C port FP0 C16 Control Unit with RS232C port EEPROM (5 k steps) 32 Input: 16 Output: 16 EEPROM (5 k steps) 32 Input: 16 Output: 16 24 V DC FP0 T32 Control Unit EEPROM with RS232C port and (10 k steps) Clock/Calendar function 32 Input: 16 Output: 16 24 V DC FP0 C32 Control Unit FP0 C32 Control Unit with RS232C port FP0 S-LINK Control Unit with RS232C port Specications Built-in memory (Program Number of I/O points Power supply capacity) voltage EEPROM (5 k steps) 128 (S-LINK Input: 64 section) Output: 64 24 V DC Input Output Product number Connection type Part number FP0-C10RS FP0-C10RM FP0-C10CRS FP0-C10CRM Terminal block FP0-C14RS 24 V DC Sink/Sourse (±common) Relay output: 2 A Molex connector FP0-C14RM 24 V DC Terminal block FP0-C14CRS Sink/Sourse (±common) Relay output: 2 A Molex connector FP0-C14CRM Transistor output: FP0-C16T 24 V DC NPN 0.1 A Sink/Sourse (±common) Transistor output: MIL connector FP0-C16P PNP 0.1 A Transistor output: FP0-C16CT NPN 0.1 A 24 V DC Sink/Sourse (±common) Transistor output: MIL connector FP0-C16CP PNP 0.1 A Transistor output: FP0-C32T 24 V DC NPN 0.1 A Sink/Sourse (±common) Transistor output: MIL connector FP0-C32P PNP 0.1 A Transistor output: FP0-C32CT 24 V DC NPN 0.1 A MIL connector Transistor output: Sink/Sourse (±common) FP0-C32CP PNP 0.1 A Transistor output: 24 V DC FP0-T32CT NPN 0.1 A MIL connector Sink/Sourse (±common) Transistor output: FP0-T32CP PNP 0.1 A Terminal block 24 V DC Relay output: 2 A Sink/Sourse (±common) Molex connector Terminal block 24 V DC Relay output: 2 A Sink/Sourse (±common) Molex connector Terminal block 24 V DC AFP02123 AFP02113 AFP02123C AFP02113C AFP02223 AFP02213 AFP02223C AFP02213C Product number Part number FP0 CC-Link Slave Unit 24 V DC FP0ñCCLS AFP07943 FP0 I/O Link Unit This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system). This is an RS485 adapter designed to allow use of the Computer link function for connecting to a host computer via C-NET. It comes with a 30cm 11.811 inch FP0 tool port cable. A power supply is not required. 24 V DC FP0ñIOL AFP0732 C-NET Adapter S2 Type (for FP0 side) 100 to 240 V AC Specications This unit is for making the FP0 function as a slave station of the CC-Link. Only one unit can be connected to the furthest right edge of the FP0 expansion bus. Note: Accuracy will change if an FP0 thermocouple unit is used at the same time. For details, please refer to the catalog or to the CC-Link Unit manual. AFP02343 C-NET Adapter (RS485) (for computer side) This is an RS485 adapter designed to allow use of the Computer link function for connecting to a network-connected PLC via C-NET from a host computer. AFP02353 FP Web-Server Unit Unit for connecting FP series/RS232C interface and Ethernet Web-Server function and E-mail sending function AFP02343C AFP02353C AFP02553 AFP02543C AFP02553C Product name FP0 Power Supply Unit Product name FP0 E8 Expansion Unit FP0 E16 Expansion Unit Number of I/O points 8 Input: 8 Input: 4 Output: 4 8 Output: 8 Power supply voltage 8 16 Input: 16 16 Input: 8 Output: 8 16 Input: 8 Output: 8 16 Output:16 Output 24 V DC Sink/Sourse (±common) 8 Output: 8 Input 24 V DC 24 V DC Product number Connection type MIL connector Part number AFP03003 FP0-E8X Terminal block FP0-E8RS 24 V DC Relay output: 2 A Sink/Sourse (±common) Molex connector FP0-E8RM Relay output: 2 A Terminal block FP0-E8YRS FP0-E8YT Transistor output: MIL connector FP0-E8YP NPN 0.1 A 24 V DC MIL connector FP0-E16X Sink/Sourse (±common) AFP03023 AFP03013 AFP03020 AFP03040 AFP03050 24 V DC Terminal block Sink/Sourse (±common) Relay output: 2 A Molex connector 24 V DC Transistor output: MIL connector Sink/Sourse (±common) NPN 0.1 A AFP03323 AFP03313 AFP03343 AFP03353 AFP03340 AFP03350 AFP03543 AFP03553 Transistor output: NPN 0.1 A MIL connector FP0-E16RS FP0-E16RM FP0-E16T FP0-E16P FP0-E16YT FP0-E16YP FP0-E32T FP0-E32P AFP03303 Input: 16 Transistor output: 24 V DC FP0 E32 MIL connector 32 Output:16 NPN 0.1 A Sink/Sourse (±common) Expansion Unit Notes 1) The control units and relay output type expansion units come with a power cable (part number AFP0581). (The transistor output type expansion units need no power cable.) 2) The terminal block type relay output units have 2 terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm .098 inch wide screwdriver. Preferably use the specific terminal block screwdriver (part number AFP0806, Phoenix type code SZS0, 4 × 2.5 mm .098 inch) or equivalent. 3) The connector-type relay output units have 2 connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins). Use the specific Molex connector press-fit tool (part number AFP0805, Nihon Molex type code 57189-5000) or equivalent. 4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number AXY52000) for wire-pressed terminal cable. 3 Intelligent units Specications Product name FP0 Analog I/O Unit FP0 A/D Converter Unit FP0 D/A Converter Unit FP0 Thermocouple Unit 14 Number or channels : 2 channels Input range : 0 to 5 V, -10 to +10 V (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) Output specifications Number or channels : 1 channels Output range : -10 to +10 V (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) Input specifications Number or channels : 8 channels Input range : 0 to 5, -10 to +10 V (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) Output specifications Number or channels : 4 channels Output range : -10 to +10 V (Resolution: 1/4000) 4 to 20 mA (Resolution: 1/4000) Product number 24 V DC Part number Specications Output: 0.7 A, 24 V DC Input voltage: 100 to 240 V AC Product name AFP0480 FP0-A80 AFP0401 FP0-A04V AFP04121 K, J, T, R thermocouple, Resolution: 0.1 °C FP0-A04 I FP0-TC4 AFP04123 AFP0420 K, J, T, R thermocouple, Resolution: 0.1 °C FP0-TC8 AFP0421 AFP0610 Product number Part number FP0-PSA4 AFP0634 Standard Programming Tool Software Control FPWIN GR Ver.2 Part number Specifications English-language menu Standard Upgrade (to upgrade from Ver.1.1) AFPS10520 Chinese-language menu Standard Upgrade (to upgrade from Ver.1.1) AFPS10820 Korean-language menu Standard AFPS10920 Full type (for all type FP series PLC) AFPS50540 Small type (for FP0, FPΣ, FP1, FP-e and FP-M) AFPS51540 Upgrade (for full type) AFPS50540R Conforms to IEC61131-3 Programming Tool Software Control FPWIN Pro Ver.5 English-language menu PC Connection Cable Between D-sub 9 pins and DIN 5 pins, 3 m length AFPS10520R AFPS10820R AFC8503 7 Options and additional parts Product name Specifications Part number Data clear type AFP8670 Data hold type AFP8671 Terminal Screwdriver Relay output type Necessary when wiring terminals block (Phoenix). AFP0806 Molex Connector Pressure Contact Tool Necessary when wiring relay output type and Molex connectors. (MOLEX: 57189-5000) AFP0805 Multi-Wire Connector Pressure Contact Tool Necessary when wiring transistor output type connectors. AXY52000 Slim 30 Type Mounting Plate Screw-stop attachment plate for 30 mm 1.181 inch width the unit. AFP0811 (set for 10) Slim Type Mounting Plate Screw-stop attachment plate for FP0 expansion unit. Slim model. AFP0803 (set for 10) Flat Type Mounting Plate Screw-stop attachment plate for FP0 control unit. Flat model. FP Memory Loader AFP0804 (set for 10) Relay Output Molex Type I/O Cable Loose-wiring cable (9 leads) AWG20, with Molex socket attached at one end, 0.5 mm2, 1 set: 2 cables (blue & white). Length: 1 m 3.281 ft. AFP0551 (2 cable set) Transistor Output Type I/O Cable Wire-pressed terminal cable (10 leads) AWG22, 0.3 mm2 with connectors attached at one end, 1 set: 2 cables (blue & white). Length: 1 m 3.281 ft. AFP0521 (2 cable set) Flat Cable Connector for FPΣ/FP0 Transistor Type Unit If you are using flat cable connector, request the part specified below for a connector with an asymmetrical design to prevent mistaken polarity. (10-pin) Terminal Socket Attaches to relay output and terminal block type. Additional part Molex Socket Attaches to relay output and Molex connector types. Additional part Wire-Press Socket Attaches to transistor output type. Additional part Power Cable Attaches to FP0 various units. Additional part Length: 1 m 3.281 ft. Input specifications FP0-A21 AFP8532 FP-WEB 6 Programming tools AFP02643C AFP02653C AFP8536 24 V DC 5 Power supply unit 2 Expansion units Specications AFP15402 AFP02543 AFP02700 FP0-SL1 Power supply voltage Product name Length: 3 m 9.843 ft. AFP0553 (2 cable set) Length: 3 m 9.843 ft. AFP0523 (2 cable set) AXM110915 AFP0802 (2 sockets per pack) AFP0801 (2 sockets per pack) AFP0807 (2 sockets per pack) AFP0581 (1 socket per pack) 15 FP0 Mounting plates FP0 Options ■ Installation and dimensions ■ Wiring tools ● Direct mounting on a panel 1: Use of the slim type mounting plate The control unit and expansion units can be directly mounted on a panel by using the optional slim type mounting plate. Control unit only Control unit + Expansion units Terminal screwdriver Molex connector pressure contact tool Multi-wire connector pressure contact tool Necessary when wiring relay output type and terminals block (Phoenix). Necessary when wiring connector type and relay output Necessary when wiring transistor output type connectors. Part number: AFP0806 ■ Parts for mounting 25.0 .984 10.0 .394 100 3.937 6.0 .236 UP UP UP UP 90.0 3.543 φ 5.0 φ .197 AFP0803 30 1.181 60.0 2.362 φ 10.0 φ .394 3.5 .138 φ 5.0 φ .197 2.5 .098 AFP0803 AFP0803 AFP0803 AFP0803 6 .236 60.0 2.362 6.2 .244 6.0 .236 UP 90.0 3.543 φ 5.0 φ .197 AFP0803 Slim 30 type mounting plate Slim type mounting plate Screw-stop attachment plate. 30 mm 1.181 inch width type Screw-stop attachment plate. Slim model. Part number: AFP0811 (set of 10) When mounting the 32-I/O-point type or FP0SL1 control unit, position the right-side surface of the unit flush with that of the plate. 60.0 2.362 3- φ5.0 3- φ.197 10.0 .394 3.5 .138 AFP0804 2.5 .098 2.2 .087 60.0 70.0 2.362 2.756 75.0 2.953 25.0 25.0 25.0 .984 .984 .984 60.0 ±0.5 2.362 ±.020 25.0 .984 90.0 3.543 60.0 2.362 φ 10.0 φ .394 AFP0811 UP 90.0 3.543 60.0 2.362 φ 10.0 φ .394 4.0 .158 Part number: AXY52000 UP 45 1.772 30 1.181 4.0 .158 Four plates connected φ 10.0 φ .394 φ 5.0 10 φ .197 .394 4 .157 17.5 12.5 .689 .492 UP 30 1.181 45 1.772 62.5 2.460 One plate Dimensions after mounting with the slim type mounting plates 90 3.543 ● Mounting dimensions (Unit: mm inch) Slim type mounting plate Part number: AFP0805 17.5 .689 Part number: AFP0803 (set of 10) 60.0 ±0.5 2.362 ±.020 3- φ 5.0 3- φ .197 φ 5.0 φ .197 φ 10.0 φ .394 4.0 .158 Flat type mounting plate 60.0 ±0.5 2.362 ±.020 Screw-stop attachment plate. Flat model. Part number: AFP0804 (set of 10) 12.5 .492 60.0 2.362 3- φ 5.0 3- φ .197 ■ Flat cable connector ■ I/O cables If you are using flat cable connector, request the part specified below for a connector with an asymmetrical design to prevent mistaken polarity. φ 5.0 φ .197 Part number: AXM110915 ● Direct mounting on a panel 2: Use of the flat type mounting plate (Note: Expansion is impossible.) The control unit can be directly mounted on a panel by using the optional flat type mounting plate. Mounting on a DIN rail is also possible. Mounting on a panel Relay output Molex type I/O cable Transistor output type I/O cable Loose-wiring cable (9 leads) AWG20, with Molex socket attached at one end, 0.5 mm2,1 set: 2 cables (blue & white). 2 cable set 2 cable set Wire-pressed terminal cable (10 leads) AWG22, 0.3 mm2 with connectors attached at one end, 1 set: 2 cables (blue & white). 2 cable set 2 cable set Part number: AFP0551 Part number: AFP0553 Part number: AFP0521 Part number: AFP0523 Notes: • One I/O cable set (2 cables) is necessary with the following models: FP0-C10RS/C10RM, C14RS/C14RM, E8RS/E8RM, E16RS/E16RM • One I/O cable set (2 cables) is necessary with the following models: FP0-C16T/C16P/E16X/E16T/E16P/E16YT/E16YP • Two I/O cable sets (total 4 cables) are necessary with the following models: FP0-C32T/C32P/E32T/E32P ● Mounting dimensions (Unit: mm inch) Flat type mounting plate Dimensions after mounting with the flat type mounting plate 31.2* 1.228 25.0*.984 60.0 2.362 6.2 .244 ■ Additional parts YO–7 0 RUN 1 2 3 PROG. 4 5 6 ERROR 7 ALARM RUN UP 90.0 3.543 AFP0804 2.2 .086 16 4.0 .157 φ 5.0 φ .197 φ 10.0 φ .394 60.0 ±0.5 2.362 ±.020 60.0 2.362 PROG. 90.0 3.543 YO–7 0 1 2 3 4 5 6 7 3- φ 5.0 3- φ.197 * When mounting the 32-I/O-point type or FP0-SL1 control unit, these dimensions increase by 5 mm .197 inch each. Terminal socket Molex socket Wire-press socket Power cable Attaches to relay output and terminal block type. Additional part Attaches to relay output and Molex connector types. Additional part Attaches to transistor output type. Additional part Attaches to control unit and relay output type expansion unit. Additional part Length: 1 m 3.281ft. Part number: AFP0581 (1 cable per pack) Part number: AFP0802 (2 sockets per pack) Part number: AFP0801 (2 sockets per pack) Part number: AFP0807 (2 sockets per pack) 17 FP0 Mounting plates FP0 Options ■ Installation and dimensions ■ Wiring tools ● Direct mounting on a panel 1: Use of the slim type mounting plate The control unit and expansion units can be directly mounted on a panel by using the optional slim type mounting plate. Control unit only Control unit + Expansion units Terminal screwdriver Molex connector pressure contact tool Multi-wire connector pressure contact tool Necessary when wiring relay output type and terminals block (Phoenix). Necessary when wiring connector type and relay output Necessary when wiring transistor output type connectors. Part number: AFP0806 ■ Parts for mounting 25.0 .984 10.0 .394 100 3.937 6.0 .236 UP UP UP UP 90.0 3.543 φ 5.0 φ .197 AFP0803 30 1.181 60.0 2.362 φ 10.0 φ .394 3.5 .138 φ 5.0 φ .197 2.5 .098 AFP0803 AFP0803 AFP0803 AFP0803 6 .236 60.0 2.362 6.2 .244 6.0 .236 UP 90.0 3.543 φ 5.0 φ .197 AFP0803 Slim 30 type mounting plate Slim type mounting plate Screw-stop attachment plate. 30 mm 1.181 inch width type Screw-stop attachment plate. Slim model. Part number: AFP0811 (set of 10) When mounting the 32-I/O-point type or FP0SL1 control unit, position the right-side surface of the unit flush with that of the plate. 60.0 2.362 3- φ5.0 3- φ.197 10.0 .394 3.5 .138 AFP0804 2.5 .098 2.2 .087 60.0 70.0 2.362 2.756 75.0 2.953 25.0 25.0 25.0 .984 .984 .984 60.0 ±0.5 2.362 ±.020 25.0 .984 90.0 3.543 60.0 2.362 φ 10.0 φ .394 AFP0811 UP 90.0 3.543 60.0 2.362 φ 10.0 φ .394 4.0 .158 Part number: AXY52000 UP 45 1.772 30 1.181 4.0 .158 Four plates connected φ 10.0 φ .394 φ 5.0 10 φ .197 .394 4 .157 17.5 12.5 .689 .492 UP 30 1.181 45 1.772 62.5 2.460 One plate Dimensions after mounting with the slim type mounting plates 90 3.543 ● Mounting dimensions (Unit: mm inch) Slim type mounting plate Part number: AFP0805 17.5 .689 Part number: AFP0803 (set of 10) 60.0 ±0.5 2.362 ±.020 3- φ 5.0 3- φ .197 φ 5.0 φ .197 φ 10.0 φ .394 4.0 .158 Flat type mounting plate 60.0 ±0.5 2.362 ±.020 Screw-stop attachment plate. Flat model. Part number: AFP0804 (set of 10) 12.5 .492 60.0 2.362 3- φ 5.0 3- φ .197 ■ Flat cable connector ■ I/O cables If you are using flat cable connector, request the part specified below for a connector with an asymmetrical design to prevent mistaken polarity. φ 5.0 φ .197 Part number: AXM110915 ● Direct mounting on a panel 2: Use of the flat type mounting plate (Note: Expansion is impossible.) The control unit can be directly mounted on a panel by using the optional flat type mounting plate. Mounting on a DIN rail is also possible. Mounting on a panel Relay output Molex type I/O cable Transistor output type I/O cable Loose-wiring cable (9 leads) AWG20, with Molex socket attached at one end, 0.5 mm2,1 set: 2 cables (blue & white). 2 cable set 2 cable set Wire-pressed terminal cable (10 leads) AWG22, 0.3 mm2 with connectors attached at one end, 1 set: 2 cables (blue & white). 2 cable set 2 cable set Part number: AFP0551 Part number: AFP0553 Part number: AFP0521 Part number: AFP0523 Notes: • One I/O cable set (2 cables) is necessary with the following models: FP0-C10RS/C10RM, C14RS/C14RM, E8RS/E8RM, E16RS/E16RM • One I/O cable set (2 cables) is necessary with the following models: FP0-C16T/C16P/E16X/E16T/E16P/E16YT/E16YP • Two I/O cable sets (total 4 cables) are necessary with the following models: FP0-C32T/C32P/E32T/E32P ● Mounting dimensions (Unit: mm inch) Flat type mounting plate Dimensions after mounting with the flat type mounting plate 31.2* 1.228 25.0*.984 60.0 2.362 6.2 .244 ■ Additional parts YO–7 0 RUN 1 2 3 PROG. 4 5 6 ERROR 7 ALARM RUN UP 90.0 3.543 AFP0804 2.2 .086 16 4.0 .157 φ 5.0 φ .197 φ 10.0 φ .394 60.0 ±0.5 2.362 ±.020 60.0 2.362 PROG. 90.0 3.543 YO–7 0 1 2 3 4 5 6 7 3- φ 5.0 3- φ.197 * When mounting the 32-I/O-point type or FP0-SL1 control unit, these dimensions increase by 5 mm .197 inch each. Terminal socket Molex socket Wire-press socket Power cable Attaches to relay output and terminal block type. Additional part Attaches to relay output and Molex connector types. Additional part Attaches to transistor output type. Additional part Attaches to control unit and relay output type expansion unit. Additional part Length: 1 m 3.281ft. Part number: AFP0581 (1 cable per pack) Part number: AFP0802 (2 sockets per pack) Part number: AFP0801 (2 sockets per pack) Part number: AFP0807 (2 sockets per pack) 17 FP0 FP0 Dimensions ● External dimensions (unit: mm inch) ■ FP0 S-LINK Control Unit ● External dimensions (unit: mm inch) 30.0 1.181 RUN ● Terminal array PROG ERROR ADDRESS ERROR 3.5 .138 60.0 2.362 C10RS/C10RM/ C14RS/C14RM/ C10CRS/C10CRM C14CRS/C14CRM (10) (.394) 25.0 .984 60.0 2.362 Input EXPANSION CONNECTOR ERROR ALARM RUN PROG. Note 1) 90.0 3.543 90.0 3.543 Output terminal block RS232C port (C10CR, C14CR only) (9) (.354) (7.5) (.295) DIN standard rail (DIN EN50022 35 mm 1.378 inch width) attachment gap (17) (.669) Notes: 1) DIN rail is attached on the center of the unit. 2) The FP0-E8YRS is not equipped with an input terminal block. Output Approx. 130.0 5.118 X0 X0 X0 X0 X1 X1 X1 X1 X2 X2 X2 X2 X3 X3 X3 X3 X4 X4 (NC) X4 X5 X5 (NC) X5 (NC) X6 (NC) X6 (NC) X7 (NC) X7 COM COM COM COM Y0 Y0 Y0 Y0 Y1 Y1 Y1 Y1 (NC) Y2 Y2 Y2 (NC) Y3 Y3 Y3 COM COM (NC) Y4 SD 60.0 2.362 (10) (.394) 25.0 .984 EXPANSION CONNECTOR ERR 1 2 3 4 ALARM RUN EXPANSION CONNECTOR MODE PROG. RUN PROG E16RS/E16RM/ E8YRS E8RS/E8RM (unit: mm inch) 60.0 2.362 (10) (.394) ● External dimensions ● RS232C port Terminal array 1 2 3 4 5 SET 90.0 3.543 24V 0V D G 24V IN 0V OFF ON V0 90.0 3.543 I 0 IN COM V1 FP0 - SL1 Input terminal block Note 2) ■ FP0 Analog I/O Unit, D/A Converter Unit I 1 V OUT I COM (7.5) (.295) (9) (.354) SG RD DIN standard rail (DIN EN50022 35 mm 1.378 inch width) attachment gap (17) (.669) SD ■ FP0 A/D Converter Unit, Thermocouple Unit Y2 Y4 (NC) Y5 ● External dimensions COM COM (NC) Y6 (unit: mm inch) Y3 Y5 (NC) Y7 COM COM COM COM 25.0 .984 FP0 - A21 ■ Control units and expansion units * For the relay output type, the terminal block type is listed as the representative type. FP0-C10RS/C10RM/C10CRS/C10CRM/C14RS/C14RM/C14CRS/C14CRM FP0-E8RS/E8RM/E8YRS/E16RS/E16RM ■ FP0 CC-Link Unit, I/O Link Unit ● External dimensions (unit: mm inch) (10) (.394) 25.0 .984 60.0 2.362 60.0 2.362 (13) (.512) FP0-C16T/C16P/C16CT/C16CP/E16T/E16P/E8X/E8YT/E8YP 3.5 .138 60.0 2.362 Note 3) Input connector 25.0 .984 Input (8 points/common) 60.0 2.362 18 .709 XO-7 0 RUN 1 2 EXPANSION CONNECTOR 3 PROG. 4 5 6 7 ERROR ALARM RUN PROG. YO-7 90.0 3.543 Note 1) 0 90.0 3.543 1 2 3 4 5 6 7 Approx. 130.0 5.118 Note 2) Output connector RS232C port (C16CT/C16CP only) (9) (.354) (7.5) (.295) DIN standard rail (DIN EN50022 35 mm 1.378 inch width) attachment gap (17) (.669) Notes: 1) DIN rail is attached on the center of the unit. 2) The FP0-E8X has no output connector. 3) The FP0-E8YT and E8YP has no input connector. ● Terminal array X0 X1 X2 X3 X4 X5 X6 X7 COM COM ● RS232C port Terminal array 90.0 3.543 SD 4.5 .177 3.5 .138 SG RD ■ FP0 Power Supply Unit ● External dimensions Y1 Y3 Y5 Y7 (-) (unit: mm inch) ● External dimensions 8.50 .335 60.0 2.362 Note: Two COM terminals on the input circuit are connected inside the unit. Note 4) 60.0 2.362 Note 2) Input connector 30.0 1.181 XO-7 X8-F 0 1 RUN EXPANSION 2 3 PROG. 4 CONNECTOR 5 6 7 ERROR 8 9 ALARM A B RUN C D E F 90.0 3.543 PROG. YO-7 Note 1) Y8-F 0 90.0 3.543 1 2 3 4 5 90.0 ● Terminal array 6 X0 X1 X2 X3 X4 X5 X6 X7 COM COM X8 X9 XA XB XC XD XE XF COM COM 4.5 .177 ● RS232C port Terminal array 3.5 .138 3.5 .138 ■ External Dimensions During Expansions SG RD ● Top view (with DIN rail attached) 60.0 2.362 SD (67.5) (2.657) Output (16 points/common) 7 8 9 A B Approx. 130.0 5.118 C D E F Note 3) Output connector RS232C port (C32CT/C32CP only) (17) Notes: (.669) 1) DIN rail is attached on the center of the unit. 2) The FP0-E32T, E32P, E16X, E16YT and E16YP are 25 mm .984 inch each. 3) The FP0-E16X has no output connector. 4) The FP0-E16YT and E16YP have no input connector. 18 (9) (.354) (7.5) (.295) DIN standard rail (DIN EN50022 35 mm 1.378 inch width) attachment gap 60.0 2.362 Output terminal Input (16 points/common) 60.0 2.362 18 .709 19.2 .756 3.543 Input terminal Connection terminal 90.0 3.543 ● External dimensions (unit: mm inch) 35.0 1.378 FP0-C32T/C32P/C32CT/C32CP/E32T/E32P/E16X/E16YT/E16YP 3.5 .138 (unit: mm inch) 25.0 .984 4.5 .177 3.5 .138 ■ FP0 Web-Server Unit Output (8 points/common) Y0 Y2 Y4 Y6 (+) 90.0 3.543 FP0-CCLS ● External dimensions (unit: mm inch) Y0 Y2 Y4 Y6 (+) Y1 Y3 Y5 Y7 (-) Y8 YA YC YE (+) Y9 YB YD YF (-) B A ● Front view XO-7 X8-F XO-7 C X8-F 0 RUN XO-7 Y8-F Y8-F Notes: 1) Four COM terminals on the input circuit are connected inside the unit. 2) Two (+) terminals and two (-) terminals on the output circuit are connected respectively inside the unit. 4 8 8 8 9 8 9 A B B C D E F 7 9 A C D E 90.0 3.543 5 6 7 B C F 3 4 5 6 A B D E 1 2 4 7 9 A C 0 3 5 6 Y8-F 1 2 4 7 F YO-7 0 3 5 6 E Y8-F 1 2 3 D F YO-7 0 1 2 (45) (1.772) B C E F YO-7 0 9 B D E F YO-7 7 A C D E P ROG. 5 8 9 C D 6 7 A B C 3 4 5 8 9 A B RUN 2 3 6 7 8 9 1 4 5 6 7 8 0 2 3 4 5 6 A X8-F 1 2 3 4 ALARM XO-7 0 1 2 PROG ERROR D X8-F 0 1 D E F F (45) (1.772) A+B+C+D dimensions Control unit type FP0-C10CRS FP0-C10CRS FP0-C10RM FP0-C10CRM FP0-C14RS FP0-C14CRS FP0-C14RM FP0-C14CRM FP0-C16T FP0-C16P FP0-C16CT FP0-C16CP FP0-C32T FP0-C32P FP0-C32CT FP0-C32CP FP0-SL1 FP0-T32CT FP0-T32CP A+B A+B+C A+B+C+D A 3 expansion Control unit only 1 expansion unit 2 expansion connected units connected units connected 25 mm .984 inch 50 mm 1.969 inch 75 mm 2.953 inch 100 mm 3.937 inch 30 mm 1.181 inch 55 mm 2.165 inch 80 mm 3.150 inch 105 mm 4.134 inch 19 FP0 FP0 Dimensions ● External dimensions (unit: mm inch) ■ FP0 S-LINK Control Unit ● External dimensions (unit: mm inch) 30.0 1.181 RUN ● Terminal array PROG ERROR ADDRESS ERROR 3.5 .138 60.0 2.362 C10RS/C10RM/ C14RS/C14RM/ C10CRS/C10CRM C14CRS/C14CRM (10) (.394) 25.0 .984 60.0 2.362 Input EXPANSION CONNECTOR ERROR ALARM RUN PROG. Note 1) 90.0 3.543 90.0 3.543 Output terminal block RS232C port (C10CR, C14CR only) (9) (.354) (7.5) (.295) DIN standard rail (DIN EN50022 35 mm 1.378 inch width) attachment gap (17) (.669) Notes: 1) DIN rail is attached on the center of the unit. 2) The FP0-E8YRS is not equipped with an input terminal block. Output Approx. 130.0 5.118 X0 X0 X0 X0 X1 X1 X1 X1 X2 X2 X2 X2 X3 X3 X3 X3 X4 X4 (NC) X4 X5 X5 (NC) X5 (NC) X6 (NC) X6 (NC) X7 (NC) X7 COM COM COM COM Y0 Y0 Y0 Y0 Y1 Y1 Y1 Y1 (NC) Y2 Y2 Y2 (NC) Y3 Y3 Y3 COM COM (NC) Y4 SD 60.0 2.362 (10) (.394) 25.0 .984 EXPANSION CONNECTOR ERR 1 2 3 4 ALARM RUN EXPANSION CONNECTOR MODE PROG. RUN PROG E16RS/E16RM/ E8YRS E8RS/E8RM (unit: mm inch) 60.0 2.362 (10) (.394) ● External dimensions ● RS232C port Terminal array 1 2 3 4 5 SET 90.0 3.543 24V 0V D G 24V IN 0V OFF ON V0 90.0 3.543 I 0 IN COM V1 FP0 - SL1 Input terminal block Note 2) ■ FP0 Analog I/O Unit, D/A Converter Unit I 1 V OUT I COM (7.5) (.295) (9) (.354) SG RD DIN standard rail (DIN EN50022 35 mm 1.378 inch width) attachment gap (17) (.669) SD ■ FP0 A/D Converter Unit, Thermocouple Unit Y2 Y4 (NC) Y5 ● External dimensions COM COM (NC) Y6 (unit: mm inch) Y3 Y5 (NC) Y7 COM COM COM COM 25.0 .984 FP0 - A21 ■ Control units and expansion units * For the relay output type, the terminal block type is listed as the representative type. FP0-C10RS/C10RM/C10CRS/C10CRM/C14RS/C14RM/C14CRS/C14CRM FP0-E8RS/E8RM/E8YRS/E16RS/E16RM ■ FP0 CC-Link Unit, I/O Link Unit ● External dimensions (unit: mm inch) (10) (.394) 25.0 .984 60.0 2.362 60.0 2.362 (13) (.512) FP0-C16T/C16P/C16CT/C16CP/E16T/E16P/E8X/E8YT/E8YP 3.5 .138 60.0 2.362 Note 3) Input connector 25.0 .984 Input (8 points/common) 60.0 2.362 18 .709 XO-7 0 RUN 1 2 EXPANSION CONNECTOR 3 PROG. 4 5 6 7 ERROR ALARM RUN PROG. YO-7 90.0 3.543 Note 1) 0 90.0 3.543 1 2 3 4 5 6 7 Approx. 130.0 5.118 Note 2) Output connector RS232C port (C16CT/C16CP only) (9) (.354) (7.5) (.295) DIN standard rail (DIN EN50022 35 mm 1.378 inch width) attachment gap (17) (.669) Notes: 1) DIN rail is attached on the center of the unit. 2) The FP0-E8X has no output connector. 3) The FP0-E8YT and E8YP has no input connector. ● Terminal array X0 X1 X2 X3 X4 X5 X6 X7 COM COM ● RS232C port Terminal array 90.0 3.543 SD 4.5 .177 3.5 .138 SG RD ■ FP0 Power Supply Unit ● External dimensions Y1 Y3 Y5 Y7 (-) (unit: mm inch) ● External dimensions 8.50 .335 60.0 2.362 Note: Two COM terminals on the input circuit are connected inside the unit. Note 4) 60.0 2.362 Note 2) Input connector 30.0 1.181 XO-7 X8-F 0 1 RUN EXPANSION 2 3 PROG. 4 CONNECTOR 5 6 7 ERROR 8 9 ALARM A B RUN C D E F 90.0 3.543 PROG. YO-7 Note 1) Y8-F 0 90.0 3.543 1 2 3 4 5 90.0 ● Terminal array 6 X0 X1 X2 X3 X4 X5 X6 X7 COM COM X8 X9 XA XB XC XD XE XF COM COM 4.5 .177 ● RS232C port Terminal array 3.5 .138 3.5 .138 ■ External Dimensions During Expansions SG RD ● Top view (with DIN rail attached) 60.0 2.362 SD (67.5) (2.657) Output (16 points/common) 7 8 9 A B Approx. 130.0 5.118 C D E F Note 3) Output connector RS232C port (C32CT/C32CP only) (17) Notes: (.669) 1) DIN rail is attached on the center of the unit. 2) The FP0-E32T, E32P, E16X, E16YT and E16YP are 25 mm .984 inch each. 3) The FP0-E16X has no output connector. 4) The FP0-E16YT and E16YP have no input connector. 18 (9) (.354) (7.5) (.295) DIN standard rail (DIN EN50022 35 mm 1.378 inch width) attachment gap 60.0 2.362 Output terminal Input (16 points/common) 60.0 2.362 18 .709 19.2 .756 3.543 Input terminal Connection terminal 90.0 3.543 ● External dimensions (unit: mm inch) 35.0 1.378 FP0-C32T/C32P/C32CT/C32CP/E32T/E32P/E16X/E16YT/E16YP 3.5 .138 (unit: mm inch) 25.0 .984 4.5 .177 3.5 .138 ■ FP0 Web-Server Unit Output (8 points/common) Y0 Y2 Y4 Y6 (+) 90.0 3.543 FP0-CCLS ● External dimensions (unit: mm inch) Y0 Y2 Y4 Y6 (+) Y1 Y3 Y5 Y7 (-) Y8 YA YC YE (+) Y9 YB YD YF (-) B A ● Front view XO-7 X8-F XO-7 C X8-F 0 RUN XO-7 Y8-F Y8-F Notes: 1) Four COM terminals on the input circuit are connected inside the unit. 2) Two (+) terminals and two (-) terminals on the output circuit are connected respectively inside the unit. 4 8 8 8 9 8 9 A B B C D E F 7 9 A C D E 90.0 3.543 5 6 7 B C F 3 4 5 6 A B D E 1 2 4 7 9 A C 0 3 5 6 Y8-F 1 2 4 7 F YO-7 0 3 5 6 E Y8-F 1 2 3 D F YO-7 0 1 2 (45) (1.772) B C E F YO-7 0 9 B D E F YO-7 7 A C D E P ROG. 5 8 9 C D 6 7 A B C 3 4 5 8 9 A B RUN 2 3 6 7 8 9 1 4 5 6 7 8 0 2 3 4 5 6 A X8-F 1 2 3 4 ALARM XO-7 0 1 2 PROG ERROR D X8-F 0 1 D E F F (45) (1.772) A+B+C+D dimensions Control unit type FP0-C10CRS FP0-C10CRS FP0-C10RM FP0-C10CRM FP0-C14RS FP0-C14CRS FP0-C14RM FP0-C14CRM FP0-C16T FP0-C16P FP0-C16CT FP0-C16CP FP0-C32T FP0-C32P FP0-C32CT FP0-C32CP FP0-SL1 FP0-T32CT FP0-T32CP A+B A+B+C A+B+C+D A 3 expansion Control unit only 1 expansion unit 2 expansion connected units connected units connected 25 mm .984 inch 50 mm 1.969 inch 75 mm 2.953 inch 100 mm 3.937 inch 30 mm 1.181 inch 55 mm 2.165 inch 80 mm 3.150 inch 105 mm 4.134 inch 19 FP0 Programmable Controllers ARCT1B164E 0 ZERO Suitable for Installation Virtually Anywhere Actual size: W30 × H90 × D60 (mm) W1.181 × H3.543 × D2.362 (inch)                                    !" ## $ %     & # #' ! (     & # #' !"      I/O 10 points/14 points Relay output, terminal block type ( ) ( I/O 16 points Transistor output type ) ( I/O 32 points Transistor output type ) . / -  /  0  1  23/45%   6  7  ARCT1B164E-1 200605 )     *+,   -   *        $ http://www.nais-e.com/plc/ Matsushita Electric Works, Ltd.
FP0-SL1 价格&库存

很抱歉,暂时无法提供与“FP0-SL1”相匹配的价格&库存,您可以联系我们找货

免费人工找货